2020.0142.FR0002 yelm goi fire plansNOT FOR CONSTRUCTIONWITHOUT PRIORAHJ APPROVALCAD SERVICES BY:7625 SUNRISE BLVD. SUITE 211CITRUS HEIGHTS, CA 95610PHONE: (916)242-0259WWW.FIRE101.NET902 NE ALGIERS RD. SE YELM, WA 98597 MANUAL FIRE ALARM SYSTEM GROCERY OUTLET These drawings are prepared by FIRE101 for the exclusiveuse of FIRE101 and its client listed above. No use orduplication of these drawings is permitted without the priorwritten consent of FIRE101 or the client.PREPARED / REVIEWED BY:RONALD D. STADTMANNICET# 116668FIRE ALARM SYSTEMS - LEVEL IIIEXP. 06/01/2021CENTRAL STATION MONITORING COMPANYNAME:VYANET OPERATING GROUP INC, DBA, PARAGON COMMUNICATIONSADDRESS:410 SW COLUMBIA ST., STE.#210BEND, OR 97702PHONE NUMBER:(866) 936-6648UL LISTING #:UUFX - S2165INSTALLING CONTRACTORNAME:SAME AS SUPPLIERADDRESS:CONT. LIC. #:PROF. LIC. #:FIRE ALARM SYSTEM SUPPLIERNAME:SUPERIOR LOW VOLTAGE, LLCADDRESS:2345 MCGILCHRIST ST. SE, STE# 6SALEM, OR 97302PHONE NUMBER:503-806-3031CONTRACTORSLICENSE #:602 961 754PROJECT DATANAME:GROCERY OUTLETADDRESS:902 NE ALGIERS RD. SEYELM, WA 98597DESCRIPTION:GROCERY STOREOCCUPANCY TYPE:M OCCUPANCY LOAD: <500BUILDING AREATOTAL: ≈ 22,500 SQ. FT.SPRINKLER SYSTEM:YESFA0.0VICINITYGENERAL NOTES1. THE SYSTEM SHALL BE A LOW VOLTAGE, POWER LIMITED, CENTRAL STATION SIGNALING SYSTEM.2. EACH ZONE SHALL ANNUNCIATE AT THE F.A.C.U. AND CENTRAL STATION3. NOT USED.4. SYSTEM SHALL HAVE PRIMARY POWER (120 VAC, 360 VA) FROM A 20 AMP DEDICATED SOURCE, IDENTIFIED AS FIRE ALARM CIRCUIT. ANAPPROVED RED LOCK OUT DEVICE SHALL BE PROVIDED ON ALL DEDICATED FIRE ALARM CIRCUIT BREAKERS.5. THE SYSTEM SHALL BE PROVIDED WITH BATTERY BACK UP THAT ALLOWS MINIMUM 24 HOURS STANDBY PLUS 5 MINUTES OF ALARMOPERATION.6. THE SYSTEM SHALL BE GROUNDED IN ACCORDANCE WITH NEC AND MANUFACTURER'S INSTRUCTIONS.7. ALL POWER LIMITED WIRING SHALL BE SEPARATED FROM NON-POWER LIMITED WIRING, ELECTRIC LIGHT POWER AND CLASS 1CIRCUITS BY A MINIMUM OF 2 INCHES (REF. NEC, ARTICLE 760-52 (A)(1).8. ALL POWER LIMITED CIRCUITS SHALL BE PERMANENTLY IDENTIFIED AT THE FACP AND IN THE MAIN JUNCTION BOXES.9. THE SYSTEM SHALL UTILIZE U.L./NEC-760 APPROVED POWER LIMITED FIRE CABLE, AND/OR #14 THHN/THWN IN CONDUIT.10. FACP SHALL BE INSTALLED 72" ABOVE FINISHED FLOOR TO THE TOP OF THE BOX.11. SMOKE DETECTORS SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 72 AND MANUFACTURER'S RECOMMENDATION FOR THE AREAOF INTENT.12. THE OPERABLE PART OF EACH MANUAL FIRE ALARM BOX SHALL BE NOT LESS THAN 42" AND NOT MORE THAN 48" ABOVE FLOORLEVEL.13. NOTIFICATION CIRCUIT VOLTAGE SHALL NOT DROP BELOW 8VDC.14. SUPERVISION: A. WIRING SHALL NOT BE LOOPED THROUGH DEVICES. WIRE MUST BE CUT FOR IN AND OUT CONNECTIONS. B. POINT, COMMON ANNUNCIATION AND T-TAPPING IS PROHIBITED, DATA CIRCUITS EXCEPTED. C. ALL WIRING TO THE INITIATING, NOTIFICATION DEVICES AND ANNUNCIATOR PANELS SHALL BE SUPERVISED.15. SYSTEM OPERATION: THE SYSTEM SHALL BE ELECTRICALLY SUPERVISED SO THAT THE OCCURRENCE OF A SINGLE OPEN ORGROUNDFAULT ON ANY FIELD WIRING, OR FAILURE OF PRIMARY POWER SUPPLY, WILL CAUSE A VISUAL "TROUBLE" AT THE FACP &REMOTE ANNUNCIATOR AND A "TROUBLE" SIGNAL SHALL BE TRANSMITTED TO THE APPROVED CENTRAL STATION FOR APPROPRIATEACTION.16. THE OPERATION, MAINTENANCE, AND TESTING OF THE FIRE ALARM SYSTEM SHALL BE AS REQUIRED BY NFPA 72 AND LOCAL AHJ.17. 24 HOUR EMERGENCY RESPONSE NUMBER FOR THE APPROVED CENTRAL STATION SHALL BE ON THE FIRE ALARM CONTROL UNITAND COMMUNICATOR.18. NFPA 72 REQUIRED CERTIFICATE OF COMPLETION SHALL BE PROVIDED TO THE AHJ PRIOR TO FIELD TEST.SHEET INDEXFA0.0COVER PAGE (THIS PAGE)FA1.0FIRE ALARM FLOOR PLANFA2.0SINGLE LINE DIAGRAM, BATTERY & VOLTAGE DROP CALCULATIONSFA3.0FIRE ALARM TYPICAL ELEVATIONS & DETAILSFA3.0TYPICAL FIRE ALARM CONTROL UNIT DIAGRAMSCOPE OF WORKINSTALLATION OF A MANUAL FIRE ALARM SYSTEM FOR A NEW "M" OCCUPANCY GROCERY STORE.SCOPE INCLUDES FULL NOTIFICATION COVERAGE, SPRINKLER MONITORING, AND MONITORING OFTHE AIR HANDLING UNITS.WIRE SCHEDULE/IDENTIFICATIONI.D.PARTS #FILLMANUFACTURERCIRCUITTYPEA430618AWG/2 FPLR, 300V, 75°CHONEYEWELL OR EQUALSLCN431314AWG/2 FPLR, 300V, 75°CHONEYEWELL OR EQUALNACC430618AWG/2 FPLR, 300V, 75°CHONEYEWELL OR EQUALIDCB431216AWG/4 FPLR, 300V, 75°CHONEYEWELL OR EQUALS-BUSAPPLICABLE CODES/CODE ANALYSISAPPLICABLE CODES:INTERNATIONAL BUILDING CODE2015 EDITIONINTERNATIONAL MECHANICAL CODE2015 EDITIONNATIONAL ELECTRICAL CODE2015 EDITIONNATIONAL FIRE CODE2015 EDITIONNATIONAL PLUMBING CODE2015 EDITIONNFPA 13, FIRE SPRINKLERS2015 EDITIONNFPA 72, FIRE ALARM2015 EDITIONABBREVIATIONSBFD / BFPBACK FLOW DEVICE / BACK FLOW PREVENTERNACNOTIFICATION APPLIANCE CIRCUITCELLCELLULAR COMMUNICATORNECNATIONAL ELECTRICAL CODECFMCUBIC FEET PER MINUTENFPANATIONAL FIRE PROTECTION ASSOCIATIONDACTDIGITAL ALARM COMMUNICATORNTSNOT TO SCALEDDDUCT SMOKE DETECTOROS&YOUTSIDE STEM AND YOLK(E)EXISTINGPIVPOST INDICATOR VALVEEOLEND OF LINEPOTSPLAIN OLD TELEPHONE SYSTEMFAAFIRE ALARM ANNUNCIATORRPSREMOTE POWER SUPPLYFACUFIRE ALARM CONTROL UNITSLCSIGNALING LINE CIRCUITFATCFIRE ALARM TERMINAL CABINETTELCOTELEPHONE COMPANYFPLFIRE POWER LIMITEDTSTAMPER SWITCHFPLRFIRE POWER LIMITED RISER RATEDU.L.UNDERWRITERS LABORATORYFSDFIRE SMOKE DAMPERWFWATER FLOW SWITCHGPMGALLONS PER MINUTEWPWEATHER PROOFIDCINITIATION DEVICE CIRCUIT(N)NEWAHUAIR HANDLING UNITNSITENMATRIX●FIRE ALARM SYSTEM OUTPUTSACTUATE COMMON ALARM SIGNAL INDICATOR @ FACU ACTUATE AUDIBLE FIRE ALARM GENERAL ALARM SIGNAL TRANSMIT FIRE ALARM SIGNAL TO SUPERVISING STATION ACTUATE COMMON SUPERVISORY SIGNAL INDICATOR @ FACU ACTUATE AUDIBLE SUPERVISORY SIGNAL TRANSMIT SUPERVISORY SIGNAL TO SUPERVISING STATION ACTUATE AUDIBLE COMMON TROUBLE SIGNAL @ FACU ACTUATE AUDIBLE COMMON TROUBLE SIGNAL TRANSMIT TROUBLE SIGNAL TO SUPERVISING STATION SHUT DOWN ASSOCIATED AIR HANDLERFIRE ALARM SYSTEM INPUTSABCDEFGHIJ1MANUAL FIRE ALARM PULL STATION●●●12SMOKE DETECTOR-AT FACU●●●23WATERFLOW SWITCH ACTIVATION●●●34DUCT SMOKE DETECTOR●●●●45OUTSIDE SCREW AND YOLK (OS&Y)●●●56FIRE ALARM AC POWER FAILURE●●●67FIRE ALARM SYSTEM LOW BATTERY●●●78FIRE ALARM OPEN CIRCUIT●●●89FIRE ALARM GROUND FAULT●●●910NAC CIRCUIT SHORT●●●10ABCDEFGHIJADDRESSP1.N1.024 EOL15cdP1.L1.070END OF LINECIRCUITPANELADDRESSLOOPPANELDEVICE LABEL SCHEDULECANDELADEVICE LEGENDDEVICE SYMBOLQTY.MANUFACTURERPART NO.DESCRIPTION1FIRELITEES-50X/CELL-MODCONTROL UNIT, FIRE ALARM, W/ CELLCOMMUNICATOR1FIRELITEANN-80ANNUNCIATOR, LCD1FIRELITEFCPS-24FS6POWER SUPPLY, 6A1FIRELITESD365(A)/B300-6DETECTOR, SMOKE, PHOTO, ADDRESSABLE,STD BASE2FIRELITEBG-12LXPULL BOX, MANUAL7FIRELITEMMF-301MODULE, INPUT, MINI5SYSTEM SENSORSCWLSTROBE, CEILING, WHITE13SYSTEM SENSORPC2WLHORN/STROBE, CEILING, WHITE1SYSTEM SENSORP2RKHORN/STROBE, WALL, OUTDOOR, RED1SPACE AGEACE-11DOCUMENT BOXFACPFAANACSFAIMCWPDOC 642 SFVESTIBULE1004219 SFSTOCKROOM111449 SFEXISTINGELECTRICALROOM11460 SFTRASHENCLOSURE11660 SFBALESTORAGE117656 SFDAIRYCOOLER10413788 SFSALESFLOOR10113788 SFSALESFLOOR101135 SFFRONTOFFICE102102 SFBACKOFFICE103134 SFWOMENS108129 SFMEN'S10995 SFALCOVE113257 SFEQUIPMENTROOM115189 SFBREAKROOM110400 SFFREEZER106204 SFMEATCOOLER105969 SFRECEIVING112P2.N1.00915cdP2.N1.00815cdP2.N1.010 EOL30cdP2.N2.00715cdP2.N2.009 EOL75cdCP2.N2.00815cdCP2.N1.00715cdCP2.N2.004177cdCP2.N2.005177cdCP2.N2.003177cdCP2.N2.006177cdCP2.N1.00375cdCP2.N1.004150cdCP2.N1.005150cdCP2.N1.00675cdCP2.N2.001115cdCP2.N2.002115cdFACPP1DOCAIMP1.L1.002WET FLOWAIMP1.L1.003WET TAMPERAIMP1.L1.004PIVSP1.L1.001FP1.L1.005P2.N1.00175cdWPFAAP1.ANN.001FP1.L1.010AIMP1.L1.008VRFC-4AIMP1.L1.009VRFC-3AIMP1.L1.006VRFC-1AIMP1.L1.007VRFC-2NACP2CP2.N1.002115cd1 A1 B1 A1 B1 N1 A1 B1 N1 A1 B1 N1 N1 N1 A1 B1 N1 N1 N1 N1 N1 N1 N1 N1 A1 B1 N1 NNOT FOR CONSTRUCTIONWITHOUT PRIORAHJ APPROVALCAD SERVICES BY:7625 SUNRISE BLVD. SUITE 211CITRUS HEIGHTS, CA 95610PHONE: (916)242-0259WWW.FIRE101.NET902 NE ALGIERS RD. SE YELM, WA 98597 MANUAL FIRE ALARM SYSTEM GROCERY OUTLET These drawings are prepared by FIRE101 for the exclusiveuse of FIRE101 and its client listed above. No use orduplication of these drawings is permitted without the priorwritten consent of FIRE101 or the client.PREPARED / REVIEWED BY:RONALD D. STADTMANNICET# 116668FIRE ALARM SYSTEMS - LEVEL IIIEXP. 06/01/2021FA1.0FIRE ALARM SYSTEM FLOOR PLAN  SCALE: 1/8" = 1'N NOTES:1PIV SHOWN HERE FOR REFERENCE ONLY. VERIFYEXACT LOCATION IN FIELD.1 FAAP1.ANN.001FACPP1NACP2P2.N1.00175cdWPCP2.N1.002115cdCP2.N1.00375cdCP2.N1.004150cdCP2.N1.005150cdCP2.N1.00675cdCP2.N1.00715cdP2.N1.00815cdP2.N1.00915cdP2.N1.010 EOL30cdCP2.N2.001115cdCP2.N2.002115cdCP2.N2.003177cdCP2.N2.004177cdCP2.N2.005177cdCP2.N2.006177cdP2.N2.00715cdCP2.N2.00815cdP2.N2.009 EOL75cd1 B1 A1 N1 NSP1.L1.001AIMP1.L1.002WET FLOWAIMP1.L1.003WET TAMPERAIMP1.L1.004PIVFP1.L1.005AIMP1.L1.006VRFC-1AIMP1.L1.007VRFC-2AIMP1.L1.008VRFC-4AIMP1.L1.009VRFC-3FP1.L1.010 PANEL P1 (ES-50X/CELL-MOD) BATTERY CALCULATIONSECONDARY POWER SOURCE REQUIREMENTSSTANDBY CURRENT (AMPS)SECONDARY ALARM CURRENT(AMPS)PANEL COMPONENTSQTYPART NODESCRIPTIONCURRENTDRAW (A)TOTAL (A)CURRENTDRAW (A)TOTAL1CELL-MODCELLULAR COMMUNICATOR,CARD1 x 0.055= 0.0551 x 0.10= 0.101ES-50X-CARDCONTROL PANEL, MOTHERBOARD1 x 0.141= 0.1411 x 0.257= 0.2571IPOTSIP and Telephone DigitalCommunicator CARD1 x 0.04= 0.041 x 0.041= 0.041CIRCUITSYMBOLQTYPART NODESCRIPTIONCURRENTDRAW (A)TOTAL (A)CURRENTDRAW (A)TOTAL (A)P1.ANN1ANN-80ANNUNCIATOR, LCD1 x 0.015= 0.0151 x 0.04= 0.04P1.L12BG-12LXPULL BOX, MANUAL2 x 0.000375= 0.000752 x 0.005= 0.017MMF-301MODULE, INPUT, MINI7 x 0.000375= 0.0026257 x 0.0006= 0.00421SD365(A)/B300-6DETECTOR, SMOKE, PHOTO,ADDRESSABLE, STD BASE1 x 0.0002= 0.00021 x 0.0045= 0.0045TOTALSTANDBY (A)0.254575TOTAL ALARM(A)0.4567REQUIRED STANDBY TIME = 24.00 HOURSREQUIRED ALARM TIME = 5 MINUTESSECONDARY STANDBY LOAD0.254575x 24.00= 6.1098 AHSECONDARY ALARM LOAD0.4567x 0.0833= 0.0381 AHSTANDBY AND ALARM LOAD SUBTOTAL6.1479 AHDERATING FACTORx 1.20SECONDARY LOAD REQUIREMENTS (AMP HOURS)7.3774 AHPROVIDE (2) 12V 12AH BATTERIES @ 24VDCFAAFAIMS PANEL P2 (FCPS-24FS6) BATTERY CALCULATIONSECONDARY POWER SOURCE REQUIREMENTSSTANDBY CURRENT (AMPS)SECONDARY ALARM CURRENT(AMPS)PANEL COMPONENTSQTYPART NODESCRIPTIONCURRENTDRAW (A)TOTAL (A)CURRENTDRAW (A)TOTAL1FCPS-24S6 Main BoardFire Alarm Power Supply MainBoard1 x 0.145= 0.1451 x 0.145= 0.145CIRCUITSYMBOLQTYPART NODESCRIPTIONCURRENTDRAW (A)TOTAL (A)CURRENTDRAW (A)TOTAL (A)P2.N11P2RKHorn/Strobe, Wall, Outdoor, Red75cd1 x 0.00= 0.001 x 0.176= 0.1761PC2WLHorn/Strobe, Ceiling, White 15cd1 x 0.00= 0.001 x 0.071= 0.0712PC2WLHorn/Strobe, Ceiling, White 75cd2 x 0.00= 0.002 x 0.143= 0.2861PC2WLHorn/Strobe, Ceiling, White115cd1 x 0.00= 0.001 x 0.187= 0.1872PC2WLHorn/Strobe, Ceiling, White150cd2 x 0.00= 0.002 x 0.217= 0.4342SCWLStrobe, Ceiling, White 15cd2 x 0.00= 0.002 x 0.041= 0.0821SCWLStrobe, Ceiling, White 30cd1 x 0.00= 0.001 x 0.063= 0.063P2.N21PC2WLHorn/Strobe, Ceiling, White 15cd1 x 0.00= 0.001 x 0.071= 0.0712PC2WLHorn/Strobe, Ceiling, White115cd2 x 0.00= 0.002 x 0.187= 0.3744PC2WLHorn/Strobe, Ceiling, White177cd4 x 0.00= 0.004 x 0.254= 1.0161SCWLStrobe, Ceiling, White 15cd1 x 0.00= 0.001 x 0.041= 0.0411SCWLStrobe, Ceiling, White 75cd1 x 0.00= 0.001 x 0.111= 0.111TOTALSTANDBY (A)0.145TOTAL ALARM(A)3.057REQUIRED STANDBY TIME = 24.00 HOURSREQUIRED ALARM TIME = 5 MINUTESSECONDARY STANDBY LOAD0.145x 24.00= 3.48 AHSECONDARY ALARM LOAD3.057x 0.0833= 0.2548 AHSTANDBY AND ALARM LOAD SUBTOTAL3.7348 AHDERATING FACTORx 1.20SECONDARY LOAD REQUIREMENTS (AMP HOURS)4.4817 AHPROVIDE (2) 12V 7AH BATTERIES @ 24VDCWPCCCCCCCPanel P2Total Used Current: (All Circuits)2.9120APoint-To-Point Voltage Drop Calculation for Panel P2 Circuit N1Starting Calculation Voltage: 20.4000v Minimum Operational Voltage: 16.0000vTotal Circuit Current: 1.2990A Total Distance: 393.7416'Voltage Drop: 1.3581v End Of Line Voltage: 19.0419vPercent Drop: 6.66 % Wire GA=#14 AWGDistance measured using drawn segment lengths with 10.00 % additional length calculatedDevice LabelPart No.DescriptionDevice CurrentDistance FromPrevious DeviceVoltage At DeviceVoltage Drop FromSourceVoltage DropPercentP2.N1.001P2RKHorn/Strobe, Wall, Outdoor, Red 75cd0.1760A1.2832'20.3914v0.0086v0.04 %P2.N1.002PC2WLHorn/Strobe, Ceiling, White 115cd0.1870A45.0090'20.1316v0.2684v1.32 %P2.N1.003PC2WLHorn/Strobe, Ceiling, White 75cd0.1430A92.0300'19.6889v0.7111v3.49 %P2.N1.004PC2WLHorn/Strobe, Ceiling, White 150cd0.2170A63.2967'19.4309v0.9691v4.75 %P2.N1.005PC2WLHorn/Strobe, Ceiling, White 150cd0.2170A86.7077'19.1742v1.2258v6.01 %P2.N1.006PC2WLHorn/Strobe, Ceiling, White 75cd0.1430A47.7456'19.0861v1.3139v6.44 %P2.N1.007PC2WLHorn/Strobe, Ceiling, White 15cd0.0710A21.6881'19.0620v1.3380v6.56 %P2.N1.008SCWLStrobe, Ceiling, White 15cd0.0410A14.9182'19.0509v1.3491v6.61 %P2.N1.009SCWLStrobe, Ceiling, White 15cd0.0410A10.2600'19.0454v1.3546v6.64 %P2.N1.010 EOLSCWLStrobe, Ceiling, White 30cd0.0630A10.8031'19.0419v1.3581v6.66 %Point-To-Point Voltage Drop Calculation for Panel P2 Circuit N2Starting Calculation Voltage: 20.4000v Minimum Operational Voltage: 16.0000vTotal Circuit Current: 1.6130A Total Distance: 492.7540'Voltage Drop: 2.1261v End Of Line Voltage: 18.2739vPercent Drop: 10.42 % Wire GA=#14 AWGDistance measured using drawn segment lengths with 10.00 % additional length calculatedDevice LabelPart No.DescriptionDevice CurrentDistance FromPrevious DeviceVoltage At DeviceVoltage Drop FromSourceVoltage DropPercentP2.N2.001PC2WLHorn/Strobe, Ceiling, White 115cd0.1870A86.4563'19.6832v0.7168v3.51 %P2.N2.002PC2WLHorn/Strobe, Ceiling, White 115cd0.1870A56.7075'19.2676v1.1324v5.55 %P2.N2.003PC2WLHorn/Strobe, Ceiling, White 177cd0.2540A45.7524'18.9762v1.4238v6.98 %P2.N2.004PC2WLHorn/Strobe, Ceiling, White 177cd0.2540A46.5878'18.7403v1.6597v8.14 %P2.N2.005PC2WLHorn/Strobe, Ceiling, White 177cd0.2540A64.1831'18.4992v1.9008v9.32 %P2.N2.006PC2WLHorn/Strobe, Ceiling, White 177cd0.2540A46.4420'18.3853v2.0147v9.88 %P2.N2.007SCWLStrobe, Ceiling, White 15cd0.0410A41.3233'18.3379v2.0621v10.11 %P2.N2.008PC2WLHorn/Strobe, Ceiling, White 15cd0.0710A10.7066'18.3279v2.0721v10.16 %P2.N2.009 EOLSCWLStrobe, Ceiling, White 75cd0.1110A94.5951'18.2739v2.1261v10.42 %NOT FOR CONSTRUCTIONWITHOUT PRIORAHJ APPROVALCAD SERVICES BY:7625 SUNRISE BLVD. SUITE 211CITRUS HEIGHTS, CA 95610PHONE: (916)242-0259WWW.FIRE101.NET902 NE ALGIERS RD. SE YELM, WA 98597 MANUAL FIRE ALARM SYSTEM GROCERY OUTLET These drawings are prepared by FIRE101 for the exclusiveuse of FIRE101 and its client listed above. No use orduplication of these drawings is permitted without the priorwritten consent of FIRE101 or the client.PREPARED / REVIEWED BY:RONALD D. STADTMANNICET# 116668FIRE ALARM SYSTEMS - LEVEL IIIEXP. 06/01/2021FA2.0BATTERY & VOLTAGE DROP CALCULATIONSSCALE: NTSSINGLE LINE DIAGRAMSCALE: NTS NOT FOR CONSTRUCTIONWITHOUT PRIORAHJ APPROVALCAD SERVICES BY:7625 SUNRISE BLVD. SUITE 211CITRUS HEIGHTS, CA 95610PHONE: (916)242-0259WWW.FIRE101.NET902 NE ALGIERS RD. SE YELM, WA 98597 MANUAL FIRE ALARM SYSTEM GROCERY OUTLET These drawings are prepared by FIRE101 for the exclusiveuse of FIRE101 and its client listed above. No use orduplication of these drawings is permitted without the priorwritten consent of FIRE101 or the client.PREPARED / REVIEWED BY:RONALD D. STADTMANNICET# 116668FIRE ALARM SYSTEMS - LEVEL IIIEXP. 06/01/2021FA3.0WOOD OR STEEL1 HOUR GYPSUMWALLBOARD ASSEMBLYWIREMOLD.STEEL PIPE,CONDUIT ORMAX. 4" DIA.STUD5/16" MAX.ANNULAR SPACEUL #WL1001CP 25 CAULK.3M FIRE BARRIERFIRE STOP/THRU-PENETRATION DETAILN.T.S.A.PENETRATION THRUGYPSUM BOARD WALLUL #CAJ1044FIRE RATEDCONCRETE WALL1" DEPTHCP 25WP CAULK3M FIRE BARRIERSTEEL PIPECONDUIT ORWIREMOLDANNULAR SPACE.1-3/8" MAXIMUMPACKINGMATERIALN.T.S.B.PENETRATION THRUCONCRETE WALLN.T.S.C.PENETRATION THRUCONCRETE FLOORFIREDAM 1503M FIRE BARRIERCAULK 1" DEPTHFLOOR SLABFIRE RATEDCONCRETEMATERIALPACKINGUL #CAJ1017STEEL PIPE1-3/8" MAX.WIREMOLDANNULAR SPACE.CONDUIT ORSYSTEM NO. WL1001(FORMERLY SYSTEM NO. 147)F RATINGS - 1,2,3, & 4 HR (SEE ITEM 2 & 3)T RATINGS - 0,1,2,3, & 4 HR (SEE ITEM 3)L RATING AT AMBIENT - LESS THAN 1 CFM/SQ FT (SEE ITEM 3)L RATING AT 400 F - LESS THAN 1 CFM/SQ FT (SEE ITEM 3)1.WALL ASSEMBLY - THE 1,2,3 OR 4 HR FIRE-RATED GYPSUM WALL BOARD/STUD WALLASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED INTHE INDIVIDUAL U300 OF U400 SERIES WALL OR PARTITION DESIGN IN THE UL FIRERESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES:A.STUDS - WALL FRAMING MAY CONSIST OR EITHER WOOD STUDS (MAX.2 HR FIRE RATEDASSEMBLIES) OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN.LUMBER SPACED IN 18 IN. CC.B.WALLBOARD, GYPSUM - NOM 12 OR 88 IN. THICK, 4 FT. WIDE WITH SQUARE OR TAPEREDEDGES. THE GYPSUM WALL BOARD RYPS, THICKNESS, NUMBER OF LAYERS, FASTENERTYPE & SHEET ORIENTATION SHALL BE SPECIFIED IN THE INDIVIDUAL U300 OR U400SERIES DESIGN IN THE UL FIRE RESISTANCE DIRECTORY. MAX DIAM OF OPENING IS13-1/2 IN.2.PIPE OR CONDUIT - NOM 12 IN. DIAM(OR SMALLER) SCHEDULE 10 (OR HAVIER) STEEL PIPENOM 6 IN. DIAM(SMALLER) STEEL ELECTRICAL METALIC TUBING OR TYPE L OR (OR HAVIER)COPPER TUBING NOM1 IN.DIAM (OR SMALLER) FLEXIBLE STEEL CONDUIT. WHEN COPPER PIPEOR FLEXIBLE STEEL CHANNEL STUDS. A MAX OF ONE PIPE OR CONDUIT IS PERMITTED IN THEFIRESTOP SYSTEM. PIPE OR CONDUIT TO BE INSTALLED NEAR CENTER OF STUD CAVITY WIDTH& TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY.3.FILL, VOID OR CAVITY MATERIAL - CAULK - CAULK FILL MATERIAL INSTALLED TO COMPLETELYFILL ANULAR SPACE BETWEEN PIPE OR CONDUIT & GYPSUM WALL BOARD & WITH A MIN 14IN.DIAM BOARD OF CAULK APPLIED TO PERIMETER OF PIPE OR CONDUIT AT ITS EGREES FROMTHE WALL. CAULD INSTALLED SYMMETRICALLY ON BOTH SIDES OF WALL ASSEMBLY. THEHOURLY F RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE HOURLY FIRE RATINGOF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED, AS SHOWN IN THE FOLLOWING TABLE. THEHOURLY T RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE TYPE OR SIZE OF THEPIPE OR CONDUIT AND THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT ISINSTALLED, AS TABULETED BELOW:MAX PIPEANULARFTOR CONDUITSPACERATINGRATINGDIAM, ININHRHR10 TO 3/161 OR 20 + 1 OR 2114 TO 1/23 OR 43 OR 440 TO 1/41 OR 20614 TO 1/23 OR 4012316 TO 3/81 OR 20+ WHEN COPPER PIPE IS USED, T RATING IS 0 NOM. MINESSOTA MINING & MFG. CO. - TYPES CP-25 S/L, CP-25 N/8, CP-25 WS, CP-25 WS + (NOTE: L RATINGS APPLY WHEN CP-25 WS+CAULK IS USED.)THROUGH WALL PENETRATION DETAILSN.T.S.LCFNFPA 72 20164"4"12"NO LOWERDEVICE MOUNTING ELEVATIONSN.T.S.F12"NO LOWEROHMVALUE1STBAND2NDBAND3RDBAND4THBANDWATTAGEVALUE470YELLOWVIOLET2 WATTBROWNGOLD560GREENBLUE2 WATTBROWNGOLDCOLORNO.BLACK0BROWN1RED2ORANGE3YELLOW4GREEN5BLUE6VIOLET7GRAY8WHITE9COLORTOLERANCEGOLD5%SILVER10%(E.O.L.R.)1KBROWNBLACK1 WATTREDGOLD3.3KORANGEORANGE1 WATTREDGOLD6.8KBLUEGRAYREDGOLD10KBROWNBLACK1/2 WATTORANGE100KBROWNBLACK1/2 WATTYELLOWNUMBERNUMBERNUMBEROFZEROSVALUETOLERANCECOLOR CODEN.T.S.END-OF-LINE RESISTOR COLOR CODE3-0 EXTENSION RINGDETECTOR BASEDETECTOR HEAD4X4 J-BOXBOX HANGER SUPPORTFLEX CONDUITGYP. BOARD CEILINGNOTE: DETECTORS SHALL BEPLACED 3'-0" FROM ANY AIRDIFFUSERSGYP. BOARD DEVICEN.T.S.*DETAIL IS TYPICAL FOR DETECTORS AND NOTIFICATION DEVICESCEILINGDEVICE WALL MOUNT DETAILN.T.S.MANUAL PULL STATION4" SQUARE DEEPBACK BOX WITH1G TRIM RINGREFER TO MANUFACTURERSSPECIFICATIONS FOR EXACTMOUNTING REQUIREMENTSNOTIFICATIONAPPLIANCE4S DEEP BOX W/ 4SEXTENSION BOXSTRUCTURE ABOVESURFACE MOUNT DEVICEN.T.S.4X4 J-BOXDETECTOR HEADDETECTOR BASE3-0 EXTENSION RINGNOTE: DETECTORS SHALL BEPLACED 3'-0" FROM ANY AIRDIFFUSERS*DETAIL IS TYPICAL FOR DETECTORS AND NOTIFICATION DEVICESBOX HANGER 4X4 J-BOXDETECTOR HEADDETECTOR BASE3-0 EXTENSION RINGNOTE: DETECTORS SHALL BEPLACED 3'-0" FROM ALL AIRDIFFUSERSSUSPENDED CEILING FLEX CONDUIT TONEXT DETECTORSEISMIC WIRE TOSTRUCTURE ABOVESUSPENDED CEILING DEVICEN.T.S.*DETAIL IS TYPICAL FOR DETECTORS AND NOTIFICATION DEVICESFOR CLASS "B" WIRING CIRCUIT.EXAMPLE OF UTILIZING J-BOX ON PRINTWIRE RUN DETAIL- J-BOX DETAILN.T.S.NOTE: CABLE IN JBOX ARENOT TO BE T-TAPPED ORSPLICED FOR CLASS "B"CIRCUIT: TERMINATIONS ONDEVICE TERMINALS ONLY.TO AND FROMDEVICES.TYPICAL RISER CONNECTIONTYPICAL PIV CONNECTIONTYPICAL OS&Y CONNECTIONN.T.S.TYPICAL RISER, PIV AND OS&Y CONNECTIONSGOLDGOLD1/2 WATTFIRE ALARM TYPICAL ELEVATIONS & DETAILSSCALE: NTS @RTN-OUT-250VDISPLAY2ANPMRTN+OUT+BATTERYN/L2EARTHH/L1USB-ACNONCCNONCCNCNOSUPVTRBLALRMANN-LCES50-PCAREVSLCRMT SYNCANN-BUS PRIANN-BUS SECNAC2NAC124VCORRECTCORRECTINCORRECTINCORRECTCORRECTWIRING METHODSINCORRECTANN-80 REMOTE ANNUNCIATORSYSTEM SENSOR STROBESD365 & H365SD365&H365BG-12LXAUDIO AND/OR VISUAL DEVICESYSTEM SENSOR STROBEAUDIO AND/OR VISUAL DEVICECRF-300A+A-CMF-300MMF-300A+A-A+A-FIRE-LITE ES-50X FIRE ALARM CONTROL PANELAUX (-)OUTPUT 4 (NAC -)OUTPUT 4 (NAC +)AUX. TROUBLE (NO)ACGROUND FAULTBATTERYNAC TROUBLEAC/CHGR 30V15AF1AUX (+)IN2 (-)IN2 (+)OUT (-)OUT (+)IN1 (-)IN1 (+)SYNC (-)SYNC (+)EARTHNEUTRALHOT12345678910OUTPUT 3 (NAC -)OUTPUT 3 (NAC +)OUTPUT 2 (NAC -)OUTPUT 2 (NAC +)OUTPUT 1 (NAC -)OUTPUT 1 (NAC +)AUX. TROUBLE (NC)AUX. TROUBLE (COM)87654321321BATTERYJP1+-TO CHASSIS GROUNDGROUNDING STRAPJP2JP3ZNAC CONNECTORJ3FCPS-24FS8 POWER SUPPLYCONNECT TO 120 VACDEDICATED CIRCUITCONNECT TO 120 VACDEDICATED CIRCUITCELL-MOD / CELL-CABIPOTS-COMLINE1LINE2ETHBA+-(-)(+)(-)(+)(-)(+)(-)(+)NOT FOR CONSTRUCTIONWITHOUT PRIORAHJ APPROVALCAD SERVICES BY:7625 SUNRISE BLVD. SUITE 211CITRUS HEIGHTS, CA 95610PHONE: (916)242-0259WWW.FIRE101.NET902 NE ALGIERS RD. SE YELM, WA 98597 MANUAL FIRE ALARM SYSTEM GROCERY OUTLET These drawings are prepared by FIRE101 for the exclusiveuse of FIRE101 and its client listed above. No use orduplication of these drawings is permitted without the priorwritten consent of FIRE101 or the client.PREPARED / REVIEWED BY:RONALD D. STADTMANNICET# 116668FIRE ALARM SYSTEMS - LEVEL IIIEXP. 06/01/2021FA4.0TYPICAL FIRE ALARM CONTROL PANEL DIAGRAMSCALE: NTS