Loading...
2020.0218.FR0009 FA20048 PLAN - BLDG 3SHEET REV.DESCRIPTION FA001 GENERAL SHEET, LEGEND & NOTES FA101 DEVICE LOCATION VIEWS - FIRST LEVEL FA102 DEVICE LOCATION VIEWS - SECOND LEVEL FA103 DEVICE LOCATION VIEWS - THIRD LEVEL FA501 SCHEDULES & RISER DIAGRAMS FA601 PRODUCT TYPICALS FA801 POWER CALCULATIONS FA901 PRODUCT SHEETS FA902 PRODUCT SHEETS FIRE ALARM CONSTRUCTION DOCUMENT SET SHEET INDEX SMITHFIRE SYSTEMS INC.FIRE1106 54TH AVE ETACOMA, WA 98424(253) 926-1880SMITHFS861RSCONSTRUCTION SET DESIGNER: ISSUE DATE: SYSTEM: FIRE ALARM SHEET: GENERAL SHEETLEGEND & NOTES FA001DATEISSUE LOG:INT DESCRIPTION15025 TAHHOMA BLVD SEWYNDSTONE APARTMENTSBLDG #3YELM, WA 98597PARCEL #21724420300SHEET NAMING CONVENTION SHEET DESCRIPTION FA0XX GENERAL SHEET, LEGEND & NOTES FA1XX DEVICE LOCATION VIEWS - FIRST FLOOR FA2XX ELEVATION VIEWS FA3XX SECTION VIEWS FA4XX LARGE SCALE VIEWS FA5XX SCHEDULES & RISER DIAGRAMS FA6XX PRODUCT TYPICALS FA7XX DEVICE DETAILS FA8XX POWER CALCULATIONS FA9XX PRODUCT SHEETS IDENTIFIERS TYPE DESCRIPTION DEVICE IDENTIFIER - EXISTING, ADD, REPLACE, MOVE, DEMO POINT OF PROTECTION IDENTIFIER / TYPE REFERENCE REVISION IDENTIFIER CABLE ID - SEE CABLE LEGEND SHEET ID - SHEET DETAIL "A", "B", "C" / SHEET #XXXX X:XX:XXX XX XX XX XXXXXX CABLE LEGEND ID AWG COND SHEILD CLASS ID AWG SHEILD CLASS A 16 2 N FPLR AA B 16 4 N FPLR BB C 16 2 N FPLP CC D 16 4 N FPLP DD E 14 2 N FPLR EE F 14 4 N FPLR FF G 14 2 N FPLP GG H 14 4 N FPLP HH I 12 2 N FPLR II J 12 4 N FPLR JJ K 12 2 N FPLP KK L 12 4 N FPLP LL M 16 2 N TFFN MM N 16 4 N TFFN NN O 16 2 N THWN OO P 16 4 N THWN PP Q QQ U UU R RR S SS T TT U UU V VV X XX Y YY Z ZZ SHEET INDEX SHEET INDEX THE SCOPE OF THIS PROJECT IS TO INSTALL A NEW FIRE ALARM CONTROL PANEL, NOTIFICATION, AND INITIATING DEVICES FOR THE PURPOSE OF NEW CONSTRUCTION. SYSTEM CODES INTERNATIONAL BUILDING CODE (IBC 2015 EDITION) INTERNATIONAL FIRE CODE (IFC 2015 EDITION) NATIONAL FIRE PROTECTION ASSOCATION (NFPA 70 2011 EDITION) NATIONAL FIRE PROTECTION ASSOCIATION (NFPA 72 2013 EDITION) NATIONAL FIRE PROTECTION (NFPA 101 2011 EDITION) ADA INTERNATIONAL CODE ANSIE 117.1 UNDERWRITERS LABORATORIES, INCORPORATED YELM MUNICIPAL CODES USE & OCCUPANCY CLASSIFICATION ASSEMBLY (A)A-1 A-2 A-3 A-4 A-5 BUSINESS (B) EDUCATIONAL (E) FACTORY & INDUSTRIAL (F)F-1 F-2 HIGH HAZZARD (H)H-1 H-2 H-3 H-4 H-5 INSTITUTIONAL (I)I-1 I-2 I-3 I-4 MERCANTILE (M) RESIDENTIAL (R)R-1 R-2 R-3 R-4 STORAGE (S)S-1 S-2 S-3 S-4 UTILITY & MISCELLANEOUS (U) BUILDING CONSTRUCTION TYPES TYPE I TYPE II TYPE III TYPE IV TYPE V TYPE I-A TYPE I-B TYPE II-A TYPE II-B TYPE III-A TYPE III-B TYPE V-A TYPE V-B AUTOMATIC SPRINKLER PROTECTION NO PARTIAL FULL GENERAL NOTES 1. INSTALLATION SHALL BE ACCOMPLISHED IN STRICT COMPLIANCE WITH NFPA, LOCAL, AND STATE AHJ'S, NEC, AND CONTRACT DRAWINGS. 2. AS-BUILT DRAWINGS ARE REQUIRED AT THE TIME OF AHJ ACCEPTANCE. SMITH FIRE SYSTEMS REQUIRES ELECTRICAL RED LINES WITH IN TWO WEEKS PRIOR TO 3. AGREEMENT AND CONFIRMATION OF ALL MILESTONE EVENTS WILL BE MADE WITH SMITH FIRE SYSTEMS PROJECT MANAGER. ALL SMITH FIRE SYSTEMS FIELD SERVICES MUST BE SCHEDULED WITH SMITH FIRE SYSTEMS PROJECT MANAGER WITH A MINIMUM OF TEN BUSINESS DAY'S ADVANCE NOTICE. 4. A SET OF INSTALLATION AS-BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND CONDUCTOR ROUTES SHALL BE KEPT BY PROJECT FOREMAN FOR USE BY SMITH FIRE SYSTEMS ALARM TECHNICIAN. 5. FIRE ALARM CONTROL PANEL SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF A SMITH FIRE SYSTEMS ALARM TECHNICIAN. PRIOR TO AHJ TEST'S. 6. THE FIRE ALARM SYSTEM SHALL BE MONITORED BY A UNDERWRITERS LISTED MONITORING STATION BEFORE AHJ'S TEST. 7. WIRE ROUTING IS DIAGRAMMATIC IN NATURE ONLY AND NOT INTENDED FOR ACTUAL CONDUIT ROUTING. 8. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND AHJ. 9. NO LINE VOLTAGE IN SAME CONDUIT AS POWER LIMITED FIRE ALARM CABLE. 10. VERIFY ALL LOCATIONS OF DEVICES WITH ELECTRICAL AND ARCHITECTURAL PLANS. SCALE AND PLACE ALL DEVICES PER ELECTRICAL AND ARCHITECTURAL PLANS. 11. FIELD VERIFY WATERFLOW SWITCHES, TAMPER SWITCHES, PRESSURE SWITCHES, SMOKE DAMPERS, AND DUCT DETECTOR LOCATIONS. 12. FIELD VERIFY ALL WIRING LOCATIONS AND REQUIREMENTS FOR HVAC AND FAN CONTROL. 13. SMOKE DETECTORS SHALL NOT BE LOCATED WITH IN 36" OF ANY AIR DIFFUSER. 14. WALL MOUNTED AUDIBLE/VISUAL APPLIANCES SHALL BE MOUNTED IN SUCH THAT THE ENTIRE LENS IS NOT LESS THAN 80" AND NOT GREATER THE 96" ABOVE FINISHED FLOOR. 15. THE OPERABLE PART OF EACH MANUAL FIRE ALARM BOX SHALL BE NOT LESS THAN 3'-6" AND NOT MORE THAN 4'-6" ABOVE THE FINISHED FLOOR. 16. NO DETECTOR SHALL BE INSTALLED UNTIL AFTER FINAL CONSTRUCTION CLEAN-UP. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO CLEAN-UP MUST BE CLEANED OR REPLACED AND WILL BE INVOICED ON A TIME AND MATERIAL BASES. 17. A DEDICATED BRANCH CIRCUIT OF ONE OF THE FOLLOWING SHALL SUPPLY PRIMARY POWER. A) COMMERCIAL LIGHT AND POWER. B) AN ENGINE-DRIVEN GENERATOR OR EQUIVALENT WHERE A PERSON SPECIFICALLY TRAINED IN ITS OPERATIONS IS ON DUTY AT ALL TIMES. C) AN ENGINE-DRIVEN GENERATOR OR EQUIVALENT ARRANGED FOR COGENERATION WITH COMMERCIAL LIGHT AND POWER WHERE A PERSON SPECIFICALLY TRAINED IN ITS OPERATION IS ON DUTY AT ALL TIMES. 18. ALL CIRCUITS WILL BE PROPERLY TAGGED AND TESTED FOR OPENS, SHORTS, GROUNDS, AND PROPER "END-TO-LINE" RESISTANCE. EACH CIRCUITS METER READING MUST BE DOCUMENTED AND PRESENTED TO SMITH FIRE SYSTEMS ALARM TECHNICIAN UPON ARRIVAL ONSITE FOR STARTUP AND CHECKOUT. 19. NO TAPPING OF SIGNALING OR INITIATING ZONE CIRCUITS ARE ALLOWED. T-TAPPING OF STYLE 4 ADDRESSABLE CIRCUITS IS ALLOWED PROVIDING A SPLICE IS PROFESSIONALLY INSTALLED, POLARITY IS OBSERVED, AND SHIELDS ARE CONTINUOUS AND FREE OF GROUNDS. SHIELDS MUST BE TERMINATED AT THE FIRE ALARM CONTROL PANEL ONLY. CABLE SHIELDS SHALL BE SPLICED TOGETHER AT EVERY JUNCTION BETWEEN THE FIRE ALARM CONTROL PANEL AND THE LAST DEVICE ON EACH CABLE RUN. SHIELDS AND OTHER FIRE ALARM CONDUCTORS (EXCEPT POWER GROUNDS) SHALL BE INSULATED AND COMPLETELY FREE FROM CONDUIT OR EARTH GROUNDS. SHIELDS WILL BE TIED TO GROUND ONLY AT THE FIR ALARM CONTROL PANEL. DRAWING ACCEPTANCE THIS DRAWING IS TO BE USED FOR THE PURPOSE OF PLACING AND LOCATING SMITH FIRE SYSTEMS FIRE ALARM DEVICES AND IS NOT BE USED FOR ANY OTHER PURPOSES. RECORD DRAWINGS ALL WORK PERFORMED IN THE FIELD SHALL BE ACCURATELY RECORDED ON THESE DRAWINGS AND RETURNED TO SMITH FIRE SYSTEMS CORPORATE OFFICE. MONITORING COMPANY ALARM CENTER 4500 3RD AVE, LACEY, WA 98503 ACCOUNT# TBD QTY SYMBOL DEVICE DESCRIPTION 1 FIRE ALARM CONTROL PANEL FM-200 CLEAN AGENT PANEL PRE-ACTION CONTROL PANEL VOICE EVACUATION CONTROL PANEL 1 FIRE SIGNAL EXPANDER REMOTE ANNUNCIATOR SUBSCRIBER TERMINAL UNIT 1 AES RADIO FIRE ALARM - PANELS QTY SYMBOL DEVICE DESCRIPTION WALL STROBE WALL STROBE WEATHERPROOF CEILING STROBE CEILING STROBE WEATHERPROOF WALL HORN-STROBE 1 WALL HORN-STROBE WEATHERPROOF CEILING HORN-STROBE CEILING HORN-STROBE WEATHERPROOF WALL HORN CEILING HORN WALL HORN-STROBE LOW FREQUENCY 62 WALL MINI HORN LOW FREQUENCY CEILING SPEAKER WALL SPEAKER/STROBE CEILING SPEAKER/STROBE WALL CHIME CEILING CHIME WALL BUZZER CEILING BUZZER BELL FIRE ALARM - NOTIFICATION DEVICES QTY SYMBOL DEVICE DESCRIPTION 1 SMOKE DETECTOR SMOKE DETECTOR ABOVE CEILING SMOKE DETECTOR BELOW CEILING DUCT SMOKE DETECTOR DUCT SMOKE DETECTOR REMOTE TEST SWITCH SMOKE BEAM TRANSMITTER SMOKE BEAM RECEIVER 135° FIXED TEMP HEAT DETECTOR 135° RATE OF RISE HEAT DETECTOR 194° FIXED TEMP HEAT DETECTOR 194° RATE OF RISE HEAT DETECTOR 190° FIXED TEMP HEAT DETECTOR 194° LINE TYPE HEAT DETECTOR FIRE ALARM - DETECTORS QTY SYMBOL DEVICE DESCRIPTION 13 MANUAL PULL STATION MINI MONITOR MODULE MONITOR MODULE 2 TWO POINT POINT MONITOR MODULE FOUR POINT MONITOR MODULE RELAY MODULE CONTROL RELAY MODULE INPUT MODULE FOUR POINT INPUT/OUTPUT RELAY MODULE ISOLATION MODULE NOTIFICATION MODULE SYNC MODULE DOOR HOLDER FIRE ALARM - MODULE / RELAY QTY SYMBOL DEVICE DESCRIPTION SPRINKLER RISER WATER GONG BELL E WATERFLOW SWITCH PRESSURE SWITCH E TAMPER SWITCH FIRE ALARM - SPRINKLER QTY SYMBOL DEVICE DESCRIPTION ELEVATOR STATUS RECALL FIRE FIGHTERS PHONE FIRE FIGHTERS PHONE JACK FIRE FIGHTERS HANDSET FIRE ALARM - FIREMAN'S PHONE QTY SYMBOL DEVICE DESCRIPTION KITCHEN HOOD JUNCTION BOX 5 BATTERY FIRE ALARM - MISCELLANEOUS QTY SYMBOL DEVICE DESCRIPTION NURSE CALL CCTV CAMERA CCTV CAMERA WEATHERPROOF DOOR BELL DOOR BUZZER DOOR CHIME SECURITY ELECTRONIC DOOR OPENER SECURITY ELECTRONIC DOOR STRIKE INTERCOM UNIT MASTER INTERCOM & DIRECTORY MOTION DETECTOR SECURITY DOOR ALARM MAG LOCK SECURITY CARD READER SECURITY CARD READER WEATHERPROOF SECURITY CONTROL UNIT SECURITY DOOR PANEL SECURITY DOOR CONTACTS SECURITY EXIT PUSH BUTTON SECURITY KEY PAD ACCESS / SECURITY / CAMERA - DEVICES X PROJECT #: INSTALLATION COMPANY SMITH FIRE SYSTEMS 1106 54TH AVE E, TACOMA, WA 98424 JEF MARQUEZ 7/9/20 FA20048 TAHOMA BLVD SE DURANT ST SEWORK AREA A2-6A2-7A2-8 A2-11A2-10 A2-9 A1-11A1-9 A1-8 A1-12 A1-10 A1-1 A1-2A1-3 A1-4 A1-5 K K K K K K UP TO2ND FLRSLC C C C A2-14 A2-13 A2-12 K A2-3 A2-4 A5-5 A2-15 K A2-2 EOL A1-6 A1-7 EOL TOFSE/NAC-A1 K RISER PIV WATERFLOW CONTROL VALVE K K K C C C FIELD VERIFY: INSTALL WEATHERPROOF HORN/STROBEON BUILDING FACING FOREMOST OF STREET. TOFSE/NAC-A2 A2-175cd SMITHFIRE SYSTEMS INC.FIRE1106 54TH AVE ETACOMA, WA 98424(253) 926-1880SMITHFS861RSKEY PLAN KEY PLAN N.T.S. N DEVICE LOCATION VIEWS - FIRST LEVELASCALE: 1/8" = 1'-0" FA101 CONSTRUCTION SET DESIGNER: ISSUE DATE:DATEISSUE LOG:INT DESCRIPTION PROJECT #: SYSTEM: FIRE ALARM SHEET: DEVICELOCATION VIEWS JEF MARQUEZNICET LEVEL IVFIRE ALARM SYSTEMSCERT #119820EXP 7/1/22 15025 TAHHOMA BLVD SEWYNDSTONE APARTMENTSBLDG #3YELM, WA 98597PARCEL #21724420300JEF MARQUEZ 7/9/20 FA20048 DN UP UP UP A4-4A4-5A4-6 A4-9A4-8 A4-7 A3-9A3-7 A3-6 EOLA3-8 A3-1 A3-2A3-3 A3-4 A3-5 DN TOFSE/NAC-A4 K K K K K K K UP TO3RD FLRSLC C C RESTROOM RESTROOM RSTM RSTM KITCHEN LIVING RM LIVING RM RSTM RSTM CLST CLST RESTROOM RESTROOM RESTROOM RESTROOM RESTROOM RESTROOM RESTROOM RESTROOMLIVING RM LIVING RM LIVING RM LIVING RM RSTM RSTM RSTM RSTM RSTM RSTM KITCHEN KITCHEN KITCHEN KITCHEN KITCHEN LIVING RMRESTROOM RESTROOM KITCHEN KITCHEN RSTM RSTM RSTM RSTM LIVING RM RESTROOM RESTROOM A4-12 A4-11A4-10 K A4-1A4-2 A4-3 EOL DN TOFSE/NAC-A3 K A3-10 K K DN TO1ST FLRSLC C C TAHOMA BLVD SE DURANT ST SEWORK AREA SMITHFIRE SYSTEMS INC.FIRE1106 54TH AVE ETACOMA, WA 98424(253) 926-1880SMITHFS861RSKEY PLAN KEY PLAN N.T.S. DEVICE LOCATION VIEWS - SECOND LEVELBSCALE: 1/8" = 1'-0" FA102N CONSTRUCTION SET DESIGNER: ISSUE DATE:DATEISSUE LOG:INT DESCRIPTION PROJECT #: DEVICELOCATION VIEWS SYSTEM: SHEET: FIRE ALARM JEF MARQUEZNICET LEVEL IVFIRE ALARM SYSTEMSCERT #119820EXP 7/1/22 15025 TAHHOMA BLVD SEWYNDSTONE APARTMENTSBLDG #3YELM, WA 98597PARCEL #21724420300JEF MARQUEZ 7/9/20 FA20048 DN 1-11-2 1-3 1-4 1-5 1-8 1-9 1-10 1-11 1-12 DN TOFACP/NAC-1 K K K C C LIVING RM LIVING RM LIVING RM LIVING RM RESTROOMRESTROOM RESTROOMRESTROOM RSTM RSTM RSTM RSTM KITCHEN KITCHEN KITCHEN KITCHEN BONUS BONUS BONUS BONUS 1-7 1-6 1-13 1-14 DN TO2ND FLRSLC C EOL TAHOMA BLVD SE DURANT ST SEWORK AREA SMITHFIRE SYSTEMS INC.FIRE1106 54TH AVE ETACOMA, WA 98424(253) 926-1880SMITHFS861RSKEY PLAN KEY PLAN N.T.S. DEVICE LOCATION VIEWS - THIRD LEVELCSCALE: 1/8" = 1'-0" FA103N CONSTRUCTION SET DESIGNER: ISSUE DATE:DATEISSUE LOG:INT DESCRIPTION PROJECT #: DEVICELOCATION VIEWS SYSTEM: SHEET: FIRE ALARM JEF MARQUEZNICET LEVEL IVFIRE ALARM SYSTEMSCERT #119820EXP 7/1/22 15025 TAHHOMA BLVD SEWYNDSTONE APARTMENTSBLDG #3YELM, WA 98597PARCEL #21724420300JEF MARQUEZ 7/9/20 FA20048 .108mA 1-1 .108mA 1-2 .108mA 1-3 .108mA 1-4 .108mA 1-5 .108mA 1-6 FACP / NAC-2: FSE TRIGGER WATERFLOW CONTROL VALVE PIV C K K K K K K K .108mA A1-1 .108mA .108mA .108mA .108mA .108mA .108mA .108mA A1-2 A1-3 A1-4 A1-4 A1-5 A1-6 A1-7 .108mA .108mA .108mA .108mA A1-8 A1-9 A1-10 A1-11 .108mA A1-12 A2-175cd .121mA .108mA .108mA .108mA .108mA .108mA .108mA .108mA A2-2 A2-3 A2-4 A2-4 A2-5 A2-6 A2-7 .108mA A2-8 .108mA .108mA .108mA .108mA .108mA A2-9 A2-10 A2-11 A2-12 A2-13 .108mA A2-14 .108mA A2-15 EOL EOL .108mA A3-1 .108mA .108mA .108mA .108mA .108mA .108mA .108mA A3-2 A3-3 A3-4 A3-4 A3-5 A3-6 A3-7 .108mA .108mA .108mA A3-8 A3-9 A3-10 .108mA A4-1 .108mA .108mA .108mA .108mA .108mA .108mA .108mA A4-2 A4-3 A4-4 A4-4 A4-5 A4-6 A4-7 .108mA .108mA .108mA .108mA A4-8 A4-9 A4-10 A4-11 .108mA A4-12 EOL EOL .108mA 1-7 .108mA 1-8 .108mA 1-9 .108mA 1-10 .108mA 1-11 .108mA 1-12 .108mA 1-13 .108mA 1-14 EOL FACP / NAC-3: EMPTY FACP / NAC-4: EMPTY SMITHFIRE SYSTEMS INC.FIRE1106 54TH AVE ETACOMA, WA 98424(253) 926-1880SMITHFS861RSSCHEDULES & RISER DIAGRAMSA FA501 SCHEDULES - SEQUENCE OF OPERATIONS MATRIXASYSTEM TROUBLEDISPLAY OF AN ALARM EVENT AT THE FACP DISPLAY OF A SUPERVISORY EVENT AT THE FACP DISPLAY OF A TROUBLE EVENT AT THE FACP DISPLAY OF AN ALARM EVENT REMOTE ANNUNCIATOR DISPLAY OF A SUPERVISORY EVENT REMOTE ANNUNCIATOR DISPLAY OF A TROUBLE EVENT REMOTE ANNUNCIATOR TRANSMIT AN ALARM SIGNAL TO THE CENTRAL STATION TRANSMIT A SUPERVISORY SIGNAL TO THE CENTRAL STATION TRANSMIT A TROUBLE SIGNAL TO THE CENTRAL STATION ACTIVATE ALL AUDIBLE & VISIBLE DEVICES INITIATE ELEVATOR RECALL TO UPPER LEVEL INITIATE ELEVATOR RECALL TO LOWER LEVEL ILLUMINATE FIREMANS HAT POST INDICATORTAMPER SWITCHHIGH-LOW AIRDRY WATERFLOWWET WATFLOWUPPER LEVEL ELEVATOR LOBBY SMOKELOWER LEVEL ELEVATOR LOBBY SMOKEELEVATOR MACHINE RM SMOKEDUCT SMOKE DETECTORSMOKE DETECTORMANUAL PULL STATIONCONSTRUCTION SET DESIGNER: ISSUE DATE:DATEISSUE LOG:INT DESCRIPTION PROJECT #: SYSTEM: FIRE ALARM SHEET: SCHEDULES &RISER DIAGRAMS15025 TAHHOMA BLVD SEWYNDSTONE APARTMENTSBLDG #3YELM, WA 98597PARCEL #21724420300JEF MARQUEZ 7/9/20 FA20048 SMITHFIRE SYSTEMS INC.FIRE1106 54TH AVE ETACOMA, WA 98424(253) 926-1880SMITHFS861RSFA601 CONSTRUCTION SET DESIGNER: ISSUE DATE: SYSTEM: FIRE ALARM SHEET: PRODUCTTYPICALSDATEISSUE LOG:INT DESCRIPTION PROJECT #: FIRE ALARM - PHONE CONNECTION FIRE ALARM - DCVA TAMPER SWITCHES TO WALL TRANSITION AND OPEN WIRING FIRE ALARM - POWER DISCONNECT FIRE ALARM - DROP CEILING & J BOX FIRE ALARM - OS&Y TAMPER GATE VALVE RJ CORD RJ 31X BLOCK TO PHONES FIRE ALARM CONTROL PANEL SECURITY CONTROL PANEL RJ CORD PRIMARY PORT SECONDARY PORT PRIMARY PORT GRN BLK RED YLW DMARCLINE LINE CONDUIT FIRE ALARM - CEILING JUNCTION BOX SQUARE JUNCTION BOX OTCTAGON OR NO STAPLESWIRE TIEORWIRE HANGER FIRE ALARMCONDUCTOR WEATHERPROOF J-BOXWITH ELECTRICALLY SUPERVISEDCOVER TAMPER 1/2" WEATHERPROOF BOX SUPPORTARLINGTON OR EQUIVALENT 1/2" X 36" RIGID CONDUIT WEATHERPROOF1/2" FLEX CONDUIT OS&Y TAMPERSWITCH SCHEDULE 80 PVCOR RIGID CONDUIT18" & 24" SCHEDULE 40 PVC OR RIGID CONDUIT4S J-BOXGROUND LINE FIRE ALARM CONTROL PANEL DISTRIBUTION PANEL CONDUIT DEDICATED LOCKEDCIRCUIT BREAKER DRAINOUTLET WATERFLOWSWITCH SPRINKLERRISER WALL FDC 4S BOXW/ COVER 1/2" FLEXCONDUIT OS&YCONTROLVALVE CHECK VALVE TAMPERSWITCH 1/2" FLEXCONDUIT CEILING FLOOR IF TOTAL HEIGHT IS LESS THAN90", MOUNT 6" FROM CEILING NOT LESS THAN 90" AFF NFPA 72 2013, 18.4.8.1WALL MOUNTED APPLIANCES SHALL HAVE THEIR TOPSABOVE THE FINISHED FLOORS AT HEIGHTS OF NOT LESSTHAN 90" AND BELOW THE FINISHED CEILINGS ATDISTANCES OF NOT LESS THAN 6". CEILING FLOOR IF TOTAL HEIGHT IS LESS THAN90", MOUNT 6" FROM CEILING NOT LESS THAN 80" AFF NFPA 72 2013, 18.5.5.1WALL MOUNTED APPLIANCES SHALL BE MOUNTEDSUCH THAT THE ENTIRE LENS IS NOT LESS THAN 80"AND NOT GREATER THAN 96" ABOVE THE FINISHEDFLOOR. BUT NOT GREATER THAN 96" AFF CEILING FLOOR NOT LESS THAN 42" AFF NFPA 72 2013, 17.14.5THE OPERABLE PART OF A MANUALLY ACTUATEDALARM INITIATING DEVICE SHALL BE NOT LESS THE42" AND NOT MORE THAN 48" FROM THE FINISHED FLOOR. FIRE NOT MORE THAN 48" AFF CEILING FLOOR NFPA 72 2013, 17.6.3.1.3.1DETECTORS SHALL BE LOCATED ON THE CEILING NOTLESS THAN 4" FROM THE SIDEWALL OR ON THESIDEWALLS BETWEEN 4" AND 12" FROM THE CEILING. NO LESS THAN 4" NO LESS THAN 4"NO MORE THAN 12" CEILING FLOOR NFPA 72 2013, A.17.7.4.1DETECTORS SHALL NOT BE LOCATED INDIRECT AIRFLOW OR CLOSER THAN 36" FROM AN AIRSUPPLY DIFFUSER OR RETURN AIR OPENING. NO LESSTHAN 36" FIRE ALARM - STROBE MOUNTING FIRE ALARM - PULL STATION MOUNTING FIRE ALARM - SMOKE & HEAT MOUNTING FIRE ALARM - HORN MOUNTINGA B C D E F G H I J 15025 TAHHOMA BLVD SEWYNDSTONE APARTMENTSBLDG #3YELM, WA 98597PARCEL #21724420300JEF MARQUEZ 7/9/20 FA20048 SMITHFIRE SYSTEMS INC.FIRE1106 54TH AVE ETACOMA, WA 98424(253) 926-1880SMITHFS861RSPOWER CALCULATIONSA FA801 CONSTRUCTION SET DESIGNER: ISSUE DATE:DATEISSUE LOG:INT DESCRIPTION PROJECT #: POWERCALCULATIONS SYSTEM: FIRE ALARM SHEET:15025 TAHHOMA BLVD SEWYNDSTONE APARTMENTSBLDG #3YELM, WA 98597PARCEL #21724420300JEF MARQUEZ 7/9/20 FA20048 SMITH FIRE SYSTEMS INC. FIRE 1106 54TH AVE E TACOMA, WA 98424 (253) 926-1880 SMITHFS861RSPRODUCT DATA SHEETSAFA901CONSTRUCTION SETDESIGNER:ISSUE DATE:SYSTEM:FIRE ALARMSHEET:PRODUCTDATA SHEETSDATE ISSUE LOG: INT DESCRIPTIONPROJECT #:15025 TAHHOMA BLVD SE WYNDSTONE APARTMENTS BLDG #3 YELM, WA 98597 PARCEL #21724420300JEF MARQUEZ7/9/20FA20048 SMITH FIRE SYSTEMS INC. FIRE 1106 54TH AVE E TACOMA, WA 98424 (253) 926-1880 SMITHFS861RSPRODUCT DATA SHEETSBFA902CONSTRUCTION SETDESIGNER:ISSUE DATE:SYSTEM:FIRE ALARMSHEET:PRODUCTDATA SHEETSDATE ISSUE LOG: INT DESCRIPTIONPROJECT #:15025 TAHHOMA BLVD SE WYNDSTONE APARTMENTS BLDG #3 YELM, WA 98597 PARCEL #21724420300JEF MARQUEZ7/9/20FA20048