Loading...
2020.0223.FR0011 F20-09_FORT STEVENS ES0 0 0 17 0 4 0 6 0 IMPUTE DEVICES OR ACTIONS SMOKE DETECTOROUTPUT DEVICES OR ACTIONSALARM LED ACTIVATESFACP FARAP DISPLAYSUPERVISORY LED ACTIVATESTROUBLE LED ACTIVATESPIEZO ACTIVATESALARM WITH POINT ID TRANSMITTEDAES COMMUNICATORALARM INITIATING DEVICES PULLSTATION WATERFLOW SWITCH SPRINKER SUPERVISORY SWITCHES HVAC SUPERVISORY CONDITIONS SUPERVISORY INITIATING DEVICES DRILL BUTTON FACP DISPLAY / KEYPAD FUNCTION 2 KEY FUNCTION 1 KEY FUNCTION 3 KEY FUNCTION 4 KEY SYSTEM COMPONIT TROUBLE CONDITIONS NOTIFICATTION CUIRCIT DEVICE OR MODULE AC / BATTERY SUP. WITH POINT ID TRANSMITTEDTROUBLE WITH POINT ID TRANSMITTEDGENERAL ALARM NOTIFICATIONNOTIFICATION CIRCUITSAUXILIARY CONTROLSHVAC SHUT DOWNFIRE DAMPERS CLOSEEXTERIOR STROBE ONLYWATERFLOW BELLELEVATOR SHUNT HEAT DETECTOR FIRE ALARM CONTROL UNIT- SYMBOL LEGEND FACP M FAPS F FIRE ALARM POWER SUPPLY - MANUAL PULL STATION - SMOKE DETECTOR - SYSTEM SENSOR - 2WB SMOKE DETECTOR MONITOR MODULE - CEILING MOUNT HORN STROBE - SYSTEM SENSOR - SS PC2RL CEILING MOUNT STROBE - SYSTEM SENSOR - SS SCRL INDICATES CANDELA RATING OF STROBE LIGHTXXcd WP FIRE ALARM DOCUMENT BOXFAD AES RADIO - POWER PROVIDED BY FACP I EOL DENOTES END OF CIRCUIT FOR THAT NAC LOOP INDICATES WEATHER RESISTANT DESIGN FIRE ALARM ANNUNCIATOR -0FAA CEILING MOUNTED AUDIO/VISUAL SEE NOTE 2 CEILING MOUNTED HEAT/SMOKE SEE NOTE 1 SEE NOTE 6 6'-8" (80") CEILING/DECK SEE NOTE 5 CEILING MOUNTED AUDIO/VISUAL SEE NOTE 3 MAX 30'-0" (360") CEILING MOUNTED HEAT/SMOKE SEE NOTE 1 MAX 6'-0" (72") & MIN 5'-6" (66") TYP. 5'-0" (60") TYP.MAX 4'-0" (48") MIN 3'-6" (42") NOTES: 1.LOCATE CEILING MOUNTED HEAT/SMOKE DETECTORS ON THE BOTTOM OF THE DECK/SUSPENDED CEILING (NOT ON BOTTOM OF STRUCTURAL MEMBERS), AND AS INDICATED IN NFPA 72. 2.LOCATE CEILING MOUNTED NOTIFICATION DEVICES ON BOTTOM OF BEAMS OR JOISTS; WITH CLEAR LINE OF SITE IN ALL DIRECTIONS; NO GREATER THAN THIRTY (30) FEET ABOVE THE FINISHED FLOOR; AND AS INDICATED IN NFPA 72. 3.LOCATE CEILING MOUNTED NOTIFICATION DEVICES FLUSH WITH THE SUSPENDED CEILING; ALIGNED WITH LIGHTING, SPRINKLERS, AND OTHER ARCHITECTURAL FIXTURES; WITH CLEAR LINE OF SITE IN ALL DIRECTIONS; NO GREATER THAN THIRTY (30) FEET A.F.F. ; AND AS INDICATED IN NFPA 72. 4.LOCATE WALL MOUNTED NOTIFICATION DEVICES AT 80" A.F.F TO BOTTOM OF BACK BOX. 5.COORDINATE EXACT MOUNTING HEIGHT OF CONTROL PANELS, ANNUNCIATORS, AND POWER SUPPLIES WITH THE GENERAL CONTRACTOR, ELECTRICAL CONTRACTOR AND AHJ PRIOR TO INSTALLATION. 6.MEASURED TO THE OPERABLE PART OF THE PULL STATION. TYPICAL DEVICE MOUNTING HEIGHT N.T.S. SEE NOTE 5 FAA WALL MOUNTED AUDIO/VISUAL SEE NOTE 4 PULL STATION FACU FAPS SUSPENDED CEILING FINISHED FLOOR DESIGN NARRATIVE THE PURPOSE OF THIS DESIGN IS TO UPGRADE CURRENT CORRIDOR PORTION OF THE EXISTING FIRE ALARM SYSTEM TO CODE COMPLIANT LAYOUT AND DEVICES FOR DELAYED OR RESTRICTED ACCESS CORRIDORS. SMOKE DETECTION IS PROVIDED THROUGHOUT, USING CORRIDOR SPACING, SO AS NO PORTION OF THE PROTECTED AREA IS GREATER TAN .07x THE LISTED SPACING. WE ACHIEVE SPRINKLER NOTIFICATION WITH SYSTEM SENSOR NOTIFICATION DEVICES MOUNTED AT THE CEILING THROUGHOUT CORRIDORS. THE HORN STROBES ARE PLACED TO PROVIDE 15 DECIBELS ABOVE AMBIENT SOUND PRESSURE LEVELS. AMBIENT SOUND PRESSURE LEVELS ARE SPECIFIED IN TABLE A.18.3.2 FROM NFPA 72 2013 HANDBOOK. ANTICIPATED AUDIBILITY IS FIGURED BY THE "6DB RULE OF THUMB" METHOD REFERENCED IN NFPA 72 2013 HANDBOOK. MONITORING IS EXISTING AND OUT OF OUR SCOPE OF WORK. THE EXISTING ADDRESSABLE FIRE ALARM PANEL IS POWERED FROM A 20 AMP DEDICATED CIRCUIT. THE BATTERIES ARE SIZED TO PROVIDE 24 HOUR STANDBY WITH 5 MINUTES OF ALARM. COMPLETE CALCULATIONS ARE INCLUDED WITH CUT SHEETS. B2 A,B WIRE LEGEND SYMBOLS DESCRIPTION A INDICATES 1x OF THE SPECIFIED WIRE. THE LETTER CORRESPONDS TO THE WIRE TYPE, IN THE WIRE LEGEND. INDICATES 1x EACH OF THE SPECIFIED WIRE. THE LETTER CORRESPONDS TO THE WIRE TYPE, IN THE WIRE LEGEND. INDICATES 2 OF THE SPECIFIED WIRE. THE LETTER CORRESPONDS TO THE TYPE, THE EXPONENT IS THE NUMBER OF THAT WIRE. WIRE LEGEND SYMBOLS DESCRIPTION AES 0ISOLATION MODULE - 0T R H 0RELAY MODULE - 0HEAT DETECTOR - SPRINKLER TAMPER CONNECTION MONITORING SERVICE PROVIDED BY: EXISTING AND OUT OF OUR SCOPE OF WORK BUILDING DATA ADDRESS: PARCEL #: AREA: TYPE OF CONST: OCCUPANCY: 16525 100TH WAY SE YELM, WA. 64303600300 4,4367 FT2 SCHOOL - TYPE - E RUNNER SERVICE PROVIDED BY FIRETEK DESIGN AND INSTALLATION 500 CHERRY STREET SE OLYMPIA, WA 98501 EMERGENCY SERVICE NUMBER 1-360-870-4329ELEVATOR RECALL MAINELEVATOR RECALL ALTERNATEELEVATOR RECALL MACHINE ROOMELEVATOR MAIN LOBBY SMOKE DETECTOR ELEVATOR ALTERNATE LOBBY SMOKE DETECTORS ELEVATOR MACHINE ROOM SMOKE DETECTOR ELEVATOR SUPERVISORY CONDITIONS ELEVATOR SHUNT ACTIVATEDWIRE LEGEND A USE TYPEWIRE B DOOR HOLDERC 14 GAUGE 2 CONDUCTOR - FPLP DESCRIPTION CIRCUIT TO DOOR HOLDERS WIRE LEGEND DETECTION 18 GAUGE 4 CONDUCTOR - FPLPA USE TYPEWIRE NACB C DESCRIPTION CIRCUIT TO SMOKES 14 GAUGE 4 CONDUCTOR - FPLP 0WALL MOUNT LOW FREQUENCY HORN -LF SHEET INDEX SHEET NUMBER DISCRIPTION FA01 PROJECT DETAILS FA02 NORTH CORRIDOR FA03 SOUTH CORRIDOR CIRCUIT TO HORNS & STROBES WALL MOUNT MAGNETIC DOOR HOLDER - DHS-24120C 8 FA01 Sheet NumberProject Name:Date:Drawn By:Email:Job #:File Name:DWG Name:Plot Date:Version:Rev:Date:Description:FA_PLANAutoCAD LT 2021KLMKARA@FIRETEKOLYMPIA.COM8/3/2020FORT STEVENSELEMENTARY SCHOOL16525 100TH WAY SE,YELM, WA. 98597F20-09_FORT STEVENS ESF20-09 15cd75cdDCCA²,B²,CA²,B²,CA²,B²,CA²,B²A²,B²A²,B²A²A,B,CA,BA,BA,BFA02FA03N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.FA02FORT STEVENS ELEMENTARY SCHOOL -- DEVICE AND WIRE LAYOUTFA02Sheet NumberProject Name:Date: Drawn By: Email: Job #: File Name: DWG Name: Plot Date: Version: Rev:Date:Description:04'8'16'SCALE: 1/8"=1'-0"(IN FEET)FA_PLAN AutoCAD LT 2021 8/3/2020 KLM KARA@FIRETEKOLYMPIA.COM FORT STEVENS ELEMENTARY SCHOOL 16525 100TH WAY SE, YELM, WA. 98597 F20-09_FORT STEVENS ES F20-09KEY PLAN EXEOL 15cd15cd15cd75cd15cd15cdCCA,B,CNEW WIRE FROMFACP TO DOORHOLDERSTIE IN TO EXISTING BOXA,B,CA²,B²,CCCCCA²,B²A²,B²B²DDA,B,CA²,B²,CA²,B²,CA,B,CA,BA,BA,BA,BA,BAFA02FA03FA02FA03N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.FA03FORT STEVENS ELEMENTARY SCHOOL -- DEVICE AND WIRE LAYOUTFA03Sheet NumberProject Name:Date: Drawn By: Email: Job #: File Name: DWG Name: Plot Date: Version: Rev:Date:Description:04'8'16'SCALE: 1/8"=1'-0"(IN FEET)FA_PLAN AutoCAD LT 2021 KLM KARA@FIRETEKOLYMPIA.COMKEY PLAN8/3/2020 FORT STEVENS ELEMENTARY SCHOOL 16525 100TH WAY SE, YELM, WA. 98597 F20-09_FORT STEVENS ES F20-09