2020.0223.FR0011 FIRE ALARM SUBMITTAL - F20-09 - FORT STEVENS ES
500 Cherry Street SE 360.353.3157 Olympia WA 98501 LIC# BETSCEC157BP | UBI: 600-535-868 500 Cherry Street SE 360.353.3157 Olympia WA 98501 LIC# BETSCEC157BP | UBI: 600-535-868 500 Cherry Street SE 360.353.3157 Olympia WA 98501 LIC# BETSCEC157BP | UBI: 600-535-868 0 0 0 17 0 4 0 6 0 IMPUTE DEVICES OR ACTIONS SMOKE DETECTOROUTPUT DEVICES OR ACTIONSALARM LED ACTIVATESFACP FARAP DISPLAYSUPERVISORY LED ACTIVATESTROUBLE LED ACTIVATESPIEZO ACTIVATESALARM WITH POINT ID TRANSMITTEDAES COMMUNICATORALARM INITIATING DEVICES PULLSTATION WATERFLOW SWITCH SPRINKER SUPERVISORY SWITCHES HVAC SUPERVISORY CONDITIONS SUPERVISORY INITIATING DEVICES DRILL BUTTON FACP DISPLAY / KEYPAD FUNCTION 2 KEY FUNCTION 1 KEY FUNCTION 3 KEY FUNCTION 4 KEY SYSTEM COMPONIT TROUBLE CONDITIONS NOTIFICATTION CUIRCIT DEVICE OR MODULE AC / BATTERY SUP. WITH POINT ID TRANSMITTEDTROUBLE WITH POINT ID TRANSMITTEDGENERAL ALARM NOTIFICATIONNOTIFICATION CIRCUITSAUXILIARY CONTROLSHVAC SHUT DOWNFIRE DAMPERS CLOSEEXTERIOR STROBE ONLYWATERFLOW BELLELEVATOR SHUNT HEAT DETECTOR FIRE ALARM CONTROL UNIT- SYMBOL LEGEND FACP M FAPS F FIRE ALARM POWER SUPPLY - MANUAL PULL STATION - SMOKE DETECTOR - SYSTEM SENSOR - 2WB SMOKE DETECTOR MONITOR MODULE - CEILING MOUNT HORN STROBE - SYSTEM SENSOR - SS PC2RL CEILING MOUNT STROBE - SYSTEM SENSOR - SS SCRL INDICATES CANDELA RATING OF STROBE LIGHTXXcd WP FIRE ALARM DOCUMENT BOXFAD AES RADIO - POWER PROVIDED BY FACP I EOL DENOTES END OF CIRCUIT FOR THAT NAC LOOP INDICATES WEATHER RESISTANT DESIGN FIRE ALARM ANNUNCIATOR -0FAA CEILING MOUNTED AUDIO/VISUAL SEE NOTE 2 CEILING MOUNTED HEAT/SMOKE SEE NOTE 1 SEE NOTE 6 6'-8" (80") CEILING/DECK SEE NOTE 5 CEILING MOUNTED AUDIO/VISUAL SEE NOTE 3 MAX 30'-0" (360") CEILING MOUNTED HEAT/SMOKE SEE NOTE 1 MAX 6'-0" (72") & MIN 5'-6" (66") TYP. 5'-0" (60") TYP.MAX 4'-0" (48") MIN 3'-6" (42") NOTES: 1.LOCATE CEILING MOUNTED HEAT/SMOKE DETECTORS ON THE BOTTOM OF THE DECK/SUSPENDED CEILING (NOT ON BOTTOM OF STRUCTURAL MEMBERS), AND AS INDICATED IN NFPA 72. 2.LOCATE CEILING MOUNTED NOTIFICATION DEVICES ON BOTTOM OF BEAMS OR JOISTS; WITH CLEAR LINE OF SITE IN ALL DIRECTIONS; NO GREATER THAN THIRTY (30) FEET ABOVE THE FINISHED FLOOR; AND AS INDICATED IN NFPA 72. 3.LOCATE CEILING MOUNTED NOTIFICATION DEVICES FLUSH WITH THE SUSPENDED CEILING; ALIGNED WITH LIGHTING, SPRINKLERS, AND OTHER ARCHITECTURAL FIXTURES; WITH CLEAR LINE OF SITE IN ALL DIRECTIONS; NO GREATER THAN THIRTY (30) FEET A.F.F. ; AND AS INDICATED IN NFPA 72. 4.LOCATE WALL MOUNTED NOTIFICATION DEVICES AT 80" A.F.F TO BOTTOM OF BACK BOX. 5.COORDINATE EXACT MOUNTING HEIGHT OF CONTROL PANELS, ANNUNCIATORS, AND POWER SUPPLIES WITH THE GENERAL CONTRACTOR, ELECTRICAL CONTRACTOR AND AHJ PRIOR TO INSTALLATION. 6.MEASURED TO THE OPERABLE PART OF THE PULL STATION. TYPICAL DEVICE MOUNTING HEIGHT N.T.S. SEE NOTE 5 FAA WALL MOUNTED AUDIO/VISUAL SEE NOTE 4 PULL STATION FACU FAPS SUSPENDED CEILING FINISHED FLOOR DESIGN NARRATIVE THE PURPOSE OF THIS DESIGN IS TO UPGRADE CURRENT CORRIDOR PORTION OF THE EXISTING FIRE ALARM SYSTEM TO CODE COMPLIANT LAYOUT AND DEVICES FOR DELAYED OR RESTRICTED ACCESS CORRIDORS. SMOKE DETECTION IS PROVIDED THROUGHOUT, USING CORRIDOR SPACING, SO AS NO PORTION OF THE PROTECTED AREA IS GREATER TAN .07x THE LISTED SPACING. WE ACHIEVE SPRINKLER NOTIFICATION WITH SYSTEM SENSOR NOTIFICATION DEVICES MOUNTED AT THE CEILING THROUGHOUT CORRIDORS. THE HORN STROBES ARE PLACED TO PROVIDE 15 DECIBELS ABOVE AMBIENT SOUND PRESSURE LEVELS. AMBIENT SOUND PRESSURE LEVELS ARE SPECIFIED IN TABLE A.18.3.2 FROM NFPA 72 2013 HANDBOOK. ANTICIPATED AUDIBILITY IS FIGURED BY THE "6DB RULE OF THUMB" METHOD REFERENCED IN NFPA 72 2013 HANDBOOK. MONITORING IS EXISTING AND OUT OF OUR SCOPE OF WORK. THE EXISTING ADDRESSABLE FIRE ALARM PANEL IS POWERED FROM A 20 AMP DEDICATED CIRCUIT. THE BATTERIES ARE SIZED TO PROVIDE 24 HOUR STANDBY WITH 5 MINUTES OF ALARM. COMPLETE CALCULATIONS ARE INCLUDED WITH CUT SHEETS. B2 A,B WIRE LEGEND SYMBOLS DESCRIPTION A INDICATES 1x OF THE SPECIFIED WIRE. THE LETTER CORRESPONDS TO THE WIRE TYPE, IN THE WIRE LEGEND. INDICATES 1x EACH OF THE SPECIFIED WIRE. THE LETTER CORRESPONDS TO THE WIRE TYPE, IN THE WIRE LEGEND. INDICATES 2 OF THE SPECIFIED WIRE. THE LETTER CORRESPONDS TO THE TYPE, THE EXPONENT IS THE NUMBER OF THAT WIRE. WIRE LEGEND SYMBOLS DESCRIPTION AES 0ISOLATION MODULE - 0T R H 0RELAY MODULE - 0HEAT DETECTOR - SPRINKLER TAMPER CONNECTION MONITORING SERVICE PROVIDED BY: EXISTING AND OUT OF OUR SCOPE OF WORK BUILDING DATA ADDRESS: PARCEL #: AREA: TYPE OF CONST: OCCUPANCY: 16525 100TH WAY SE YELM, WA. 64303600300 4,4367 FT2 SCHOOL - TYPE - I RUNNER SERVICE PROVIDED BY FIRETEK DESIGN AND INSTALLATION 500 CHERRY STREET SE OLYMPIA, WA 98501 EMERGENCY SERVICE NUMBER 1-360-870-4329ELEVATOR RECALL MAINELEVATOR RECALL ALTERNATEELEVATOR RECALL MACHINE ROOMELEVATOR MAIN LOBBY SMOKE DETECTOR ELEVATOR ALTERNATE LOBBY SMOKE DETECTORS ELEVATOR MACHINE ROOM SMOKE DETECTOR ELEVATOR SUPERVISORY CONDITIONS ELEVATOR SHUNT ACTIVATEDWIRE LEGEND A USE TYPEWIRE B DOOR HOLDERC 14 GAUGE 2 CONDUCTOR - FPLP DESCRIPTION CIRCUIT TO DOOR HOLDERS WIRE LEGEND DETECTION 18 GAUGE 4 CONDUCTOR - FPLPA USE TYPEWIRE NACB C DESCRIPTION CIRCUIT TO SMOKES 14 GAUGE 4 CONDUCTOR - FPLP 0WALL MOUNT LOW FREQUENCY HORN -LF SHEET INDEX SHEET NUMBER DISCRIPTION FA01 PROJECT DETAILS FA02 NORTH CORRIDOR FA03 SOUTH CORRIDOR CIRCUIT TO HORNS & STROBES WALL MOUNT MAGNETIC DOOR HOLDER - DHS-24120C 8 FA01 Sheet NumberProject Name:Date:Drawn By:Email:Job #:File Name:DWG Name:Plot Date:Version:Rev:Date:Description:FA_PLANAutoCAD LT 2021KLMKARA@FIRETEKOLYMPIA.COM8/3/2020FORT STEVENSELEMENTARY SCHOOL16525 100TH WAY SE,YELM, WA. 98597F20-09_FORT STEVENS ESF20-09 15cd75cdDCCA²,B²,CA²,B²,CA²,B²,CA²,B²A²,B²A²,B²A²A,B,CA,BA,BA,BFA02FA03N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.FA02FORT STEVENS ELEMENTARY SCHOOL -- DEVICE AND WIRE LAYOUTFA02Sheet NumberProject Name:Date: Drawn By: Email: Job #: File Name: DWG Name: Plot Date: Version: Rev:Date:Description:04'8'16'SCALE: 1/8"=1'-0"(IN FEET)FA_PLAN AutoCAD LT 2021 8/3/2020 KLM KARA@FIRETEKOLYMPIA.COM FORT STEVENS ELEMENTARY SCHOOL 16525 100TH WAY SE, YELM, WA. 98597 F20-09_FORT STEVENS ES F20-09KEY PLAN EXEOL 15cd15cd15cd75cd15cd15cdCCA,B,CNEW WIRE FROMFACP TO DOORHOLDERSTIE IN TO EXISTING BOXA,B,CA²,B²,CCCCCA²,B²A²,B²B²DDA,B,CA²,B²,CA²,B²,CA,B,CA,BA,BA,BA,BA,BAFA02FA03FA02FA03N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.FA03FORT STEVENS ELEMENTARY SCHOOL -- DEVICE AND WIRE LAYOUTFA03Sheet NumberProject Name:Date: Drawn By: Email: Job #: File Name: DWG Name: Plot Date: Version: Rev:Date:Description:04'8'16'SCALE: 1/8"=1'-0"(IN FEET)FA_PLAN AutoCAD LT 2021 KLM KARA@FIRETEKOLYMPIA.COMKEY PLAN8/3/2020 FORT STEVENS ELEMENTARY SCHOOL 16525 100TH WAY SE, YELM, WA. 98597 F20-09_FORT STEVENS ES F20-09 500 Cherry Street SE 360.353.3157 Olympia WA 98501 LIC# BETSCEC157BP | UBI: 600-535-868 500 Cherry Street SE 360.353.3157 Olympia WA 98501 LIC# BETSCEC157BP | UBI: 600-535-868 500 Cherry Street SE 360.353.3157 Olympia WA 98501 LIC# BETSCEC157BP | UBI: 600-535-868 500 Cherry Street SE 360.353.3157 Olympia WA 98501 LIC# BETSCEC157BP | UBI: 600-535-868 500 Cherry Street SE 360.353.3157 Olympia WA 98501 LIC# BETSCEC157BP | UBI: 600-535-868 500 Cherry Street SE 360.353.3157 Olympia WA 98501 LIC# BETSCEC157BP | UBI: 600-535-868 500 Cherry Street SE 360.353.3157 Olympia WA 98501 LIC# BETSCEC157BP | UBI: 600-535-868 500 Cherry Street SE 360.353.3157 Olympia WA 98501 LIC# BETSCEC157BP | UBI: 600-535-868 500 Cherry Street SE 360.353.3157 Olympia WA 98501 LIC# BETSCEC157BP | UBI: 600-535-868 500 Cherry Street SE 360.353.3157 Olympia WA 98501 LIC# BETSCEC157BP | UBI: 600-535-868 500 Cherry Street SE 360.353.3157 Olympia WA 98501 LIC# BETSCEC157BP | UBI: 600-535-868 Agency Listings Photoelectric Smoke Detectors System Sensor i3™ series smoke detectors represent significant advancement in conventional detection. The i3 family is founded on three principles: installation ease, intelligence, and instant inspection. Features Plug-in detector line, mounting base included• Large wire entry port• In-line terminals with SEMS screws• Mounts to octagonal and single-gang back boxes, 4-square back • boxes, or direct to ceiling Stop-Drop ’N Lock attachment to base• Removable detector cover and chamber• Built-in remote maintenance signaling• Drift compensation and smoothing algorithms• Simplified sensitivity measurement • Wide-angle, dual-color LED indication• Loop testing via EZ Walk feature• Built-in test switch• Installation ease. The i3 line redefines installation ease with its plug-in design. This allows an installer to pre-wire bases (included with heads). The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods as well as direct mounting with drywall anchors. To complete the installation, i3 heads plug into the base with a simple Stop-Drop ’N Lock™ action. Intelligence. i3 detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the i3 line to minimize nuisance alarms. 2-wire i3 detectors can generate a remote LED- indicated maintenance signal when connected to the 2W-MOD2 loop test/maintenance module or a panel equipped with the i3 protocol. The SENS-RDR, a wireless device, displays the sensitivityof i3 detectors in terms of percent-per-foot obscuration. Instant inspection. The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector’s condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol, the EZ Walk loop test feature is available on 2-wire i3 detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. 2093290-01-E7272-1653:1523011446S911 3180932 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2009 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. A05-0318-007 • 6/09 • #2169 Ordering Information Model Thermal Wiring Alarm Current 2W-B No 2-wire 130 mA max. limited by control panel 2WT-B Yes 2-wire 130 mA max. limited by control panel 4W-B No 4-wire 20 mA @ 12 V, 23 mA @ 24 V 4WT-B Yes 4-wire 20 mA @ 12 V, 23 mA @ 24 V Accessories 2W-MOD2 2-wire loop test / maintenance module RT Removal / replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 inch (16.76 cm) diameter Smoke Detector Specifications Architectural/Engineering Specifications Smoke detector shall be a System Sensor i3 Series model number_______, listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4WT-B) with thermal sensor rated at 135°F (57.2°C). The detector shall include a mounting base for mounting to 3½-inch and 4-inch octagonal, single-gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws. The detector shall allow pre-wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual- color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24 V non-polarized Minimum: 8.5 V Maximum: 35 V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2-wire: 50 µA maximum average; 4-wire: 50 µA maximum average Maximum Alarm Current 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12 V, 23 mA @ 24 V Peak Standby Current 2-wire: 100 µA; 4-wire: n/a Alarm Contact Ratings 2-wire: n/a; 4-wire: 0.5 A @ 30 V AC/DC Physical Specifications Dimensions (including base)5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 oz (178 g) Operating Temperature Range 2W-B and 4W-B: 32°F to 120°F (0°C to 49°C); 2WT-B and 4WT-B: 32°F to 100°F (0°C to 37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (57.2°C) fixed Freeze Trouble 2WT-B and 4WT-B only: 41°F (5°C) Sensitivity 2.5%/ft nominal Input Terminals 14 to 22 AWG Mounting 3½-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Modes Power-Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby)Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid ESL DH Series Electromagnetic Fire Door Holders www.GE-InterlogixSecurity.com The DH Series Electromagnetic Fire Door Holders are constructed of the finest materials available. Each wall mount door holder is made of durable die-cast metal and finished in a high luster double chrome or brass plating for a high quality appearance. For wall mount units, standard dual voltage AC or DC inputs reduce stocking requirements with 12/24V and 24/120V models. The 24/120V model draws a mere 15mA @ 24VAC or DC, helping keep overall job costs to a minimum. Installation is easy with the ESL DH Series installation technique– an adhesive template assures alignment without secondary adjustments. No brackets are required for recessed, flush or surface mounting (the surface mounting box has three conduit ready entries). Plus, the new catch plate features two pivot points and two way adjustability to further ensure perfect alignment. Optional extension rods are also available for providing the proper gap distance between the door and wall. (Recess mounted door holder includes a 3” extension rod). The basic units offer superiority reliability with built-in transient protection and low residual magnetism so they release easily even on new ADA low pressure door closers. Overview Product InformationGE Interlogix Standard Features Extremely low current draw. Only 15mA @ 24V saves on power supplies and backup batteries New recessed mount for lowest profile look Dual voltage inputs in each unit reduces stocking requirements Self-adjusting swivel catch-plate reduces installation time and adjusts to door alignment changes Optional extension rods make installation even faster Low residual magnetism easily releases even on new ADA low pressure door closers Built-in transient protection Floor mount units available, both single and double-coil ESL Door Holders Wall & Floor Mount (insert) DH Series Electromagnetic Fire Door Holders Surface Mount Back Box Dimensions Door Magnet Extension Rod Applications and Accessories Catch Plate Assembly 2.1” 5.2cm 1.2” 3.0cm 2.75” 7.0cm 4.6” 11.7cm 1.1” 2.8cm 3.3” 8.4cm DHW (Wrench) DH-ER1 1.0” 2.54cm DH-ER3 3.0” 7.62cm 2.5” 6.4cm 2.0” 5.1cm 2.0” 5.1cm 4.7” 11.9cm 3.3” 8.4cm 2.8” 7.1cm 1.1” 2.8cm .95” 2.4cm DH Series Electromagnetic Fire Door Holders 12V 24V 24V 120V 12V 24V 24V 120V DHX*-1224 DHX*-24120 DHFM†-1224 DHFM†-24120 Performance Data 30 15 15 – 60 60 30 – 30 15 15 15 60 60 30 30 C&L C&H C&L C&H C&L C&H C&L C&H Single Single Single Single Double Double Double Double 35 35 35 35 35 35 35 35 15.9 15.9 15.9 15.9 15.9 15.9 15.9 15.9 * For all models, “X” represents either F (Flush Mount), FM (Floor Mount single-coil), R (Recessed), or S (Surface Mount). † For Floor Mount, double coil models. NOTE: Voltage supplied by a UL listed control panel Model Voltage DC/mA AC/mA Terminals Coil lbs kg. (Nominal) CLH CLH CLH CLH CLH CLH Dual Voltage Terminal Diagram for Floor MountDual Voltage Terminal Diagram for Flush Mount, Recessed or Surface Mount (C+L) Low Voltage (C+H) High Voltage Voltage References C = common L= low H = high Low Voltage High Voltage Low Voltage Application High Voltage Application DH Series Electromagnetic Fire Door Holders ©2002 GE Interlogix. All trademarks are properties of their owners. E-3969-5000KA-0702 GE Interlogix www.GE-InterlogixSecurity.com 2266 Second Street North North St. Paul, MN 55109 Phone: 651-777-2690 USA & Canada: 800-777-5485 Technical Service: 800-777-2624 12345 SW Leveton Drive Tualatin, OR 97062 Phone: 503-692-4052 USA & Canada: 800-547-2556 Technical Service: 800-648-7424 Faxback: 800-483-2495 ESL 12 or 24 VDC/VAC, recess-mount, chrome, with 3” Extension Rod ESL 24 VDC/VAC 120VAC, recess-mount, chrome, with 3” Extension Rod ESL 12 or 24 VDC/VAC, semi-flush-mount, chrome ESL 12 or 24 VDC/VAC, semi-flush-mount, brass ESL 24 VDC/VAC 120VAC, recess-mount, chrome ESL 24 VDC/VAC 120VAC, semi-flush-mount, brass ESL 12 or 24VDC/VAC, surface-mount, chrome ESL 12 or 24VDC/VAC, surface-mount, brass ESL 24VDC/VAC 120VAC, surface-mount, chrome ESL 24VDC/VAC 120VAC, surface-mount, brass Single coil, 12 or 24VDC/VAC, floor-mount, brushed steel, UL only, CUL pending Single coil, 24VDC/VAC 120VAC, floor-mount, brushed steel, UL only, CUL pending Double coil, 12 or 24VDC/VAC, floor-mount, brushed steel, UL only, CUL pending Double coil, 24VDC/VAC 120VAC, floor-mount, brushed steel, UL only, CUL pending 1” chrome 1” brass 3” chrome 3” brass Extension rod wrenches Back Plate (chrome or brass) Replacement armature, chrome Replacement armature, brass Wall Mount DHR-1224C DHR-24120C DHF-1224C DHF-1224B DHF-24120C DHF-241OB DHS-1224C DHS-1224B DHS-24120C DHS-2412OB Floor Mount DHFM1-1224 DHFM1-24120 DHFM2-1224 DHFM2-24120 Extension Rods DH-ER1C DH-ER1B DH-ER3C DH-ER3B Accessories DHW DH-BP DH-ARMC DH-ARMB Ordering Information 20/case 20/case 20/case 20/case 20/case 20/case 20/case 20/case 20/case 20/case 6/case 6/case 6/case 6/case DHS-24120C DHFM1-24120 DHS-24120C Door Holder Type of Plating Type of Mounting Voltage DHFM1-24120 Door Holder # of coils Type of Mounting Voltage Model Description Case Qty. 500 Cherry Street SE 360.353.3157 Olympia WA 98501 LIC# BETSCEC157BP | UBI: 600-535-868 Features • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Listed for ceiling mounting only The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Agency Listings 7125-1653:0504 7135-1653:0503 S5512 S4011 FM approved except for ALERT models 3057383 AVDS868-02 • 12/01/2017 • Page 3 AVDS868-02 • 12/01/2017 • Page 2 L-Series Specifications Architect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 × 4 × 1½-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 × 4 × 17⁄8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11 ⁄16 × 4 11 ⁄16 × 2 1 ⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3)8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens)6.8" diameter × 2.5" high (173 mm diameter × 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions (SBBCRL, SBBCWL) 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS868-02 • 12/01/2017 • Page 3 Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 UL Current Draw Data Horn Strobe Tones and Sound Output Data UL Max. Horn Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC DC FWR Candela Range 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 UL Max. Current Draw (mA RMS), Ceiling Horn Strobe, Candela Range (15–177 cd) DC Input 8–17.5 Volts 16–33 Volts 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1K Temporal High 111 164 69 94 147 163 184 229 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 FWR Input 16–33 Volts 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2017 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS868-02 • 12/01/2017 L-Series Dimensions Model Description Ceiling Horn Strobes PC2RL 2-Wire, Horn Strobe, Red PC2WL 2-Wire, Horn Strobe, White PC4RL 4-Wire, Horn Strobe, Red PC4WL 4-Wire, Horn Strobe, White L-Series Ordering Information Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box Model Description Ceiling Strobes SCRL Strobe, Red SCWL Strobe, White SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White 6.83" diam. (173 mm) 2.47" (62.7 mm) 1.37" (34.8 mm)6.92" diam. (175.77 mm) 2.5" (64 mm) 2-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box A0531-01 A0545-00 A0546-00 A0494-01 For a ceiling-listed horn-only device, see AVDS865 “Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications”. 500 Cherry Street SE 360.353.3157 Olympia WA 98501 LIC# BETSCEC157BP | UBI: 600-535-868 500 Cherry Street SE 360.353.3157 Olympia WA 98501 LIC# BETSCEC157BP | UBI: 600-535-868 500 Cherry Street SE 360.353.3157 Olympia WA 98501 LIC# BETSCEC157BP | UBI: 600-535-868 500 Cherry Street SE 360.353.3157 Olympia WA 98501 LIC# BETSCEC157BP | UBI: 600-535-868