2020.0232.FR0013 Material Submittals_ Fort Stevens ESSEP 2019 GFS-100 PAGE 1 OF 6 GENERAL DESCRIPTION Globe Series GL-QR sprinklers are Listed Quick Response sprinklers which utilize a 3mm frangible glass bulb as the thermosensitive operating element. These sprinklers are available in upright, pendent, and recessed pendent orien- tations. They are Listed and Approved as Standard Cover- age sprinklers and are to be installed in accordance with the guidelines of the appropriate Installation Standard being mandated by the AHJ (i.e. NFPA 13; FM 2-0). These sprin- klers are available in various K-factors, temperatures and finishes as shown. Recessed escutcheons with either ½” or ¾” vertical adjustment are available (See Approvals Ta- bles for appropriate sprinkler/escutcheon combinations and Listings). Some pendent models are additionally available with a special “Seismic” escutcheon to meet the IBC-ASCE/ SEI 7 requirements for use in seismic design categories C, D & E. TECHNICAL DATA SIN • Upright: GL2815, GL4215, GL5615, GL8115, GL8118 • Pendent, Recessed Pendent: GL2801, GL4201, GL5601, GL8101, GL8106 Approvals • cULus • FM • LPCB • CE • See Approval Tables Maximum Working Pressure • 175 psi (12 bar) • Factory tested to 500 psi (34 bar) Minimum Operating Pressure • 7 psi (48 kPa) Temperature Rating • See Approval Tables Materials of Construction • Frame - bronze • Deflector - brass • Screw - brass • Lodgement Wire - stainless steel • Bulb seat - copper • Spring - nickel alloy • Seal - teflon • Bulb - glass with alcohol based solution, 3mm • Escutcheon Assembly - carbon steel SERIES GL-QR STANDARD COVERAGE, QUICK RESPONSE UPRIGHT, PENDENT & RECESSED PENDENT SPRINKLERS K-FACTOR: 2.8, 4.2, 5.6, 8.0 FINISHES AND ACCESSORIES Finishes • Factory Bronze • Chrome • White Polyester • Black Polyester - special order Escutcheons • Brass • Chrome • White Polyester • Black Polyester Wrenches • Standard • Recess • 1/2” NPT • 3/4” NPT UPRIGHT RECESSED PENDENT RECESSED PENDENT SEISMIC IBC/ASCE/SEI CODES PENDENT OPERATION Upon exposure to heat such as from a fire, the fluid in the bulb expands, compressing the air bubble within the bulb. When the air bubble can no longer compress, the fluid ex- pansion causes breakage of the glass bulb, resulting in re- lease of the water seat assembly, and discharge of water from the sprinkler. 4077 Airpark Dr. Standish, MI 48658 • 989-846-4583 • www.globesprinkler.com Technical Support • 989-414-2600 • techservice@globesprinkler.com NOTE: Users should refer to Globe’s web site (www.globesprinkler.com) to ensure that the most recent technical literature is being utilized. NOTE: Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be expected when exposed to corrosive atmospheres. Although corrosion resistant coated sprinklers have passed the standard corrosion tests of the applicable approval agencies, the testing is not representative of all possible corrosive atmo- spheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, humidity, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. SERIES GL-QR STANDARD COVERAGE, QUICK RESPONSE UPRIGHT, PENDENT & RECESSED PENDENT SPRINKLERS K-FACTOR: 2.8, 4.2, 5.6, 8.0 SERIES GL-QR STANDARD COVERAGE, QUICK RESPONSE UPRIGHT, PENDENT & RECESSED PENDENT SPRINKLERS K-FACTOR: 2.8, 4.2, 5.6, 8.0 GFS-100 GFS-100 SEP 2019 GFS-100 PAGE 2 OF 6 NOTICE Do not install any bulb-type sprinkler if the bulb is cracked or there is loss of liquid from the bulb. Sprinklers should be tightened enough to obtain a leak-tight joint when water pressure is applied and/or hydrostatic test is performed. Sprinklers should not be overtightened as this can result in distortion and subsequent leak-age. It is recommended not to exceed 14 ft.-lb. (19.0 Nm) torque for 1/2 inch NPT sprinkler threads; 20 ft.-lb. (26.8 Nm) to 3/4 inch NPT threads. Step1. Sprinklers must be properly oriented. Step2. With pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprin- kler fitting. Note: Do not grasp the sprinkler by the deflector. Step3. Wrench-tighten the sprinkler using only the appropriate wrench. Wrenches are only to be applied to the sprinkler wrench flats or wrench hex as applicable. Note: Do not apply wrench to frame arms. INSTALLATION CARE AND MAINTENANCE Prior to installation, it is important to read and follow the “Sprinkler Caution” sheet (GFS-840) included within each box of sprinklers. This sheet is available on Globe’s web site (www.globesprinkler.com). Store sprinklers in a cool, dry place. Exposure to extreme heat will damage the thermal sensing element, possibly re- sulting in premature activation. Avoid direct sunlight. Replace any sprinkler that shows any corrosion, damage, or loss of liquid from the glass bulb. Do not attempt to paint or alter the sprinkler’s coating in any manner after leaving the manufacturing plant. Do not attach wiring, ropes, decorations or fixtures to a sprinkler. Absence of an escutcheon, used to cover a ceiling hole, may delay sprinkler operation in a fire situation. It is the owner’s responsibility for inspection, testing and maintenance of the fire sprinkler system with all components and devices in accordance with the National Fire Protection Association Pamphlet 25 as well as any other requirements as set forth by the local Authority Having Jurisdiction (AHJ). FIGURE 1: STANDARD SPRINKLER WRENCH ½" NPT P/N 325390 ¾" NPT P/N 312366 FIGURE 2: RECESSED SPRINKLER WRENCH ½" NPT P/N 325391 ¾" NPT P/N 325401 SEP 2019 GFS-100 PAGE 3 OF 6 SIN GL2815 GL4215 (1)GL5615 (1)GL8115 *GL8118 (1) ORIENTATION UPRIGHT UPRIGHT UPRIGHT UPRIGHT UPRIGHT K-FACTOR 2.8 (40 metric)4.2 (60 metric)5.6 (80 metric)8.0 (115 metric)8.0 (115 metric) NPT 1/2” (15mm)1/2” (15mm)1/2” (15mm)1/2” (15mm)3/4” (20mm) HAZARD L.H.L.H L.H./O.H.L.H./O.H.L.H./O.H. cULus Listed 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) FM Approved NA NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) LPCB Ref. No. 147c/05 NA NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) CE NA NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) TABLE A: UPRIGHT SPRINKLER APPROVALS * FOR RETROFIT USE ONLY (1) cULus LISTED CORROSION RESISTANT WITH POLYESTER COATING. FIGURE 3: SERIES GL-QR UPRIGHT SPRINKLERS GL2815, GL4215, GL5615, GL8115 FIGURE 4: SERIES GL-QR UPRIGHT SPRINKLERS GL8118 SEP 2019 GFS-100 PAGE 4 OF 6 SIN GL2801 GL4201 (1)GL5601 (1)GL8101 *GL8106 (1) ORIENTATION PENDENT PENDENT PENDENT PENDENT PENDENT K-FACTOR 2.8 (40 metric)4.2 (60 metric)5.6 (80 metric)8.0 (115 metric)8.0 (115 metric) NPT 1/2” (15mm)1/2” (15mm)1/2” (15mm)1/2” (15mm)3/4” (20mm) HAZARD L.H.L.H L.H./O.H.L.H./O.H.L.H./O.H. cULus Listed 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) FM Approved NA NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) LPCB Ref. No. 147c/05 NA NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) CE NA NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) TABLE B: PENDENT SPRINKLER APPROVALS * FOR RETROFIT USE ONLY (1) cULus LISTED CORROSION RESISTANT WITH POLYESTER COATING. FIGURE 5: SERIES GL-QR PENDENT SPRINKLERS GL2801, GL4201, GL5601, GL8101 FIGURE 6: SERIES GL-QR PENDENT SPRINKLERS GL8106 SEP 2019 GFS-100 PAGE 5 OF 6 FIGURE 8: SEISMIC RECESSED ESCUTCHEON Meets IBC-ASCE/SEI 7 Codes for Seismic areas C, D, & E. A A 4 1/2" (114mm) DIA. 3 7/8" (98mm)- 4"(101mm) DIA. MIN. HOLE IN CEILING 1 29/32" (48mm) DIA. 1/8" (3mm) MIN. 5/8" (16mm) MAX. - 1/2" (12mm) ADJ. 7/8" (22mm) MAX. - 3/4" (19mm) ADJ. 1/4"(6mm) 1" (25mm) MIN. 1 1/2" (38mm) MAX. - 1/2" ADJ. 1 3/4" (44mm) MAX. - 3/4" ADJ. CEILING CUP RETAINER REDUCER 2 15/16" DIA. 2" DIA. MIN. HOLE IN CEILING 1 29/32" DIA. 1/8"1" MIN. 1 3/4" MAX. 1/8" MIN. 5/8" MAX. - 1/2" ADJ. 7/8" MAX. - 3/4" ADJ. REDUCER RETAINER CUP CEILING FIGURE 7: RECESSED ESCUTCHEON SIN GL2801 (2)GL4201 (1) (2)GL5601 (1) (2)GL8101 * (1) (2)GL8106 (1) (2) (3) ORIENTATION RECESSED PEND.RECESSED PEND.RECESSED PEND.RECESSED PEND.RECESSED PEND. K-FACTOR 2.8 (40 metric)4.2 (60 metric)5.6 (80 metric)8.0 (115 metric)8.0 (115 metric) NPT 1/2”1/2”1/2”1/2”3/4” HAZARD L.H.L.H L.H./O.H.L.H./O.H.L.H./O.H. cULus Listed 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) FM Approved Note: ½” Adjustable Recessed Escutcheon only NA NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) LPCB Ref. No. 147c/05 NA NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) CE NA NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) NA 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) TABLE C: RECESSED PENDENT SPRINKLER APPROVALS TABLE E: SEISMIC ESCUTCHEONS 3/4" ADJUSTABLE FRICTION FIT RECESSED ESCUTCHEON (SEISMIC) FINISH 1/2” NPT 3/4” NPT Chrome 326170 326177 White 326172-W 326178-W 1/2" ADJUSTABLE FRICTION FIT RECESSED ESCUTCHEON (SEISMIC) FINISH 1/2” NPT 3/4” NPT Chrome 326201 326208 White 326203-W 326210-W TABLE D: STANDARD ESCUTCHEONS 3/4" ADJUSTABLE FRICTION FIT RECESSED ESCUTCHEON FINISH 1/2” NPT 3/4” NPT Chrome 325422 325423 Brass 325424 325420 White Polyester 325426-W 325427-W Black Polyester 325426-B 325427-B Stainless Steel 326140 NA 1/2" ADJUSTABLE FRICTION FIT RECESSED ESCUTCHEON FINISH 1/2” NPT 3/4” NPT Chrome 332071 326040 Brass 332072 326041 White Polyester 332073-W 326042-W Black Polyester 332073-B 326042-B * FOR RETROFIT USE ONLY (1) cULus LISTED CORROSION RESISTANT SPRINKLER WITH POLYESTER COATING (2) cULus / LPCB /CE APPROVED WITH 1/2" ADJUSTABLE AND 3/4" ADJUSTABLE RECESSED ESCUTCHEON (3) FM APPROVED FOR BRASS FINISH ONLY SEP 2019 GFS-100 PAGE 6 OF 6 PART NUMBER SIN + TEMPERATURE + FINISH XXXX XXX XX SIN TEMPERATURE FINISH GL2815 2815 135 135°F (57°C)01 BRONZE GL4215 4215 155 155°F (68°C)02 CHROME GL5615 5615 175 175°F (79°C)03 WHITE POLYESTER GL8115 8115 200 200°F (93°C)04 BLACK POLYESTER GL8118 8118 286 286°F (141°C) GL2801 2801 GL4201 4201 GL5601 5601 Note: All combinations may not be available. Refer to Listing/Approval Tables for available listed combinations.GL8101 8101 GL8106 8106 TABLE F: PART NUMBER SELECTION GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 Airpark Dr. Standish, MI 48658 • 989-846-4583 • www.globesprinkler.com Technical Support • 989-414-2600 • techservice@globesprinkler.com ORDERING INFORMATION • SPRINKLER • ESCUTCHEON • WRENCH • Quantity • Finish • Part Number (See TABLE D & TABLE E) • Quantity • SIN • Orientation • Orifice • NPT • Temperature Rating • Finish • Part Number (See TABLE F) • Quantity • Part Number 1/2” NPT Standard . . . . . . . . . . . . . . . . . . . .325390 3/4” NPT Standard . . . . . . . . . . . . . . . . . . . .312366 1/2” NPT Recess . . . . . . . . . . . . . . . . . . . . .325391 3/4” NPT Recess . . . . . . . . . . . . . . . . . . . . .325401 SPECIFY: PROJECT: ENGINEER: LOCATIONS: CONTRACTOR: SPECIFICATION REFERENCE: DATE: SYSTEM TYPE: COMMENTS: SUBMITTAL INFORMATION FM Approved and Fully Listed Sprinkler Pipe Wheatland Tube’s Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL® and C-UL Listed. Approvals and Specifications Schedule 10 and Schedule 40 meet or exceed the following standards: • ASTM A135, Type E, Grade A (Schedule 10, 1–8 NPS) • ASTM A795, Type E, Grade A (Schedule 40, 1–2 NPS) • ASTM A53, Type E, Grade B (Schedule 40, 2–8 NPS) • ASTM A53, Type F, Grade A (Schedule 40, 1–4 NPS) • NFPA® 13 and NFPA 14 Manufacturing Protocols Schedule 10 and Schedule 40 are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. Finishes and Coatings All Wheatland black steel fire sprinkler pipe receives a proprietary mill coating to ensure a clean, corrosion-resistant surface that outperforms and outlasts standard lacquer coatings. This coating allows the pipe to be easily painted, without special preparation. Schedule 10 and Schedule 40 can be ordered in black or hot-dip galvanized, to meet FM / UL requirements for dry systems that meet the zinc coating specifications of ASTM A795 or A53. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Bar coding is acceptable as a supplementary identification method. Fire Sprinkler Pipe   Schedule 10 and Schedule 40 Submittal Data Sheet BLACK HOT-DIP GALVANIZED info@wheatland.com wheatland.com Follow us on Twitter: @WheatlandTube 700 South Dock Street Sharon, PA 16146 P 800.257.8182 F 724.346.7260 Fire Sprinkler Pipe   Schedule 10 and Schedule 40 Submittal Data Sheet info@wheatland.com wheatland.com Follow us on Twitter: @WheatlandTube 700 South Dock Street Sharon, PA 16146 P 800.257.8182 F 724.346.7260 WFS-081619 SCHEDULE 10 WEIGHTS AND DIMENSIONS NPS NOMINAL OD NOMINAL ID NOMINAL WALL WT. / FT. WT. / FT. H2O FILLED PCS. / LIFT WT. / LIFT 21' WT. / LIFT 24' WT. / LIFT 25'UL in.mm in.mm in.mm lbs.lbs.lbs.lbs.lbs.CRR* 1 1.315 33.4 1.097 27.9 0.109 2.77 1.405 1.814 70 2065 2360 2459 11.4 1 1/4 1.660 42.2 1.442 36.6 0.109 2.77 1.807 2.514 61 2315 2645 2756 7.3 1 1/2 1.900 48.3 1.682 42.7 0.109 2.77 2.087 3.049 61 2673 3055 3183 5.8 2 2.375 60.3 2.157 54.8 0.109 2.77 2.640 4.222 37 2051 2344 2442 4.7 2 1/2 2.875 73.0 2.635 66.9 0.120 3.05 3.354 5.895 30 2226 2544 2651 3.5 3 3.500 88.9 3.260 82.8 0.120 3.05 4.336 7.949 19 1730 1977 2060 2.6 4 4.500 114.3 4.260 108.2 0.120 3.05 5.619 11.789 19 2242 2562 2669 1.6 5 5.563 141.3 5.295 134.5 0.134 3.40 7.780 17.309 13 2124 2427 2529 1.5 6 6.625 168.3 6.357 161.5 0.134 3.40 9.298 23.038 10 1953 2232 2325 1.0 8 8.625 219.1 8.249 209.5 0.188 4.78 16.960 40.086 7 2493 2849 2968 2.1 SCHEDULE 40 WEIGHTS AND DIMENSIONS NPS NOMINAL OD NOMINAL ID NOMINAL WALL WT. / FT.WT. / FT. H2O FILLED PCS. / LIFT WT. / LIFT 21' WT. / LIFT 24' WT. / LIFT 25'UL in.mm in.mm in.mm lbs.lbs.lbs.lbs.lbs.CRR* 1 1.315 33.4 1.049 26.6 0.133 3.38 1.68 2.055 70 2470 2822 2940 1.000 1 1/4 1.660 42.2 1.380 35.1 0.140 3.56 2.27 2.922 51 2431 2778 2894 1.000 1 1/2 1.900 48.3 1.610 40.9 0.145 3.68 2.72 3.602 44 2513 2872 2992 1.000 2 2.375 60.3 2.067 52.5 0.154 3.91 3.66 5.109 24 1845 2108 2196 1.000 2 1/2 2.875 73.0 2.469 62.7 0.203 5.16 5.80 7.871 20 2436 2784 2900 1.000 3 3.500 88.9 3.068 77.9 0.216 5.49 7.58 10.783 13 2069 2365 2464 1.000 3 1/2 4.000 101.6 3.548 90.1 0.226 5.74 9.12 13.400 10 1915 2189 2280 1.000 4 4.500 114.3 4.026 102.3 0.237 6.02 10.80 16.311 10 2268 2592 2700 1.000 5 5.563 141.3 5.047 158.2 0.258 6.55 14.63 23.262 7 2151 2458 2560 1.000 6 6.625 168.3 6.065 154.1 0.280 7.11 18.99 31.498 5 1994 2279 2374 1.000 8**8.625 219.1 7.981 202.7 0.322 8.18 28.58 50.240 5 3001 3430 3573 1.000 * Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). ** 8 NPS Schedule 40 is FM Approved but not UL Listed.