Loading...
2020.0237.MP0066 Yelm - Silva 20816 AC site plan - equip specs (3)KafflEMA INK H eating and Air Conditioning 4 703 - 116" Street E, Tacoma, WA 98446 253-537-0655 / 253-539-3861 Fax HEAT PUMP SITE PLAN Date$ � �\� Address ) �/ C -A 6 I t Y S Homeowner 1 �l W 11 ly� Job #� b % b Rear Property Line i ----------------------------I I I I I I I I I I I I I i I I t t I i t I t I I I I t I I I I 1 t � I I I I � � I Front Property Line Box/PERMITS/HP Site Plan 3.25-16 kk Pnnted 3/25/16 � § 0 U E 2 to ] CL ( 2 ] _ - - ) _ [ LU Z0 _ :- � M _ o SERVICE PANEL ELECTRICAL AND REF COMPONENT CLEARANC PER PREVAILING COD TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524 (5 FEET) ABOVE UNIT. UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT. AND SHOULD BE AT LEAST 305 (12') FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTRICTED. ELECTRICAL K 25 11► A 22.2 (718) DIA. HOLE -- LOW (71 VOLTAGE / 2 11.118) DIA. K.O. WIT T 22.2 17181 DIA. HOLE IN CONTROL BOY BOTTOM FOR ELECTRICAL POTTER SUPPLY H I F J -g.0. FOR ALTERNATE 0 ELECTRICAL ROUTING LIQUID LINE SERVICE VALVE. 'E' I.D. FEMALE BRAZE CONNECTION WITH 1/4' SAE GAS LINE 114 TURN BALL SERVICE VALVE. 'D' FLARE PRESSURE TAP FITTINGS. I.D. FEMALE BRAZED CONNECTION WITH 114' SAE FLARE PRESSURE TAP FITTING. Model Base A B C D E F G H J K 4TTR6036J 4 943 -] (37-1/8) 946 87Q 3/4 {37-1/4} (34-1/4} 3/8 143 (5-5/8) 98 {3-7/8} 219 86 (8-5/8) (3-3/8) 508 {20) 2 4TTR6036J-SUB-1A-EN SOUND POWER LEVEL Model A -Weighted Sound Power Level [dB(A)] Full Octave Sound Power [dB] 63 Hz* 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 41TR6036J 71 78 72 69 68 66 61 58 53 1 I Note: Rated in accordance with AHRI Standard 270-2008 *For Reference Only 77l 2 4TTR6036J-SUB-1A-EN TRANE. Product Specifications OUTDOOR UNIT (a) (b) 4TTR6036J 1000A POWER CONNS. — V/PH/HZ (c) 208/230/1/60 MIN. BRCH. CIR. AMPACITY 18 BR. CIR. PROT. RTG. — MAX. (AMPS) 30 COMPRESSOR . .: ` CLIMATAUFF@- SCROLL NO. USED — NO. STAGES 1— 1 VOLTS/PH/HZ 208/230/1/60 R. L. AMPS (d)— L.R. AMPS 13.6 — 79 FACTORY INSTALLED START COMPONENTS (e) NO (Uses BAYKSKT263) INSULATION/SOUND BLANKET NO COMPRESSOR HEAT NO OUTDOOR FAN PROPELLER DIA. (IN.) — NO. USED 27.5-1 TYPE DRIVE — NO. SPEEDS DIRECT— 1 CFM @ 0.0 IN. W.G. M 4300 N0. MOTORS —HP 1-1/8 MOTOR SPEED R.P.M. 850 VOLTS/PH/HZ 200/230/1/60 F.L. AMPS 0.64 OUTDOOR COIL —TYPE SPINE FINTM' ROWS — F.P.I. 1-24 FACE AREA (SQ. FT.) 24.93 TUBE SIZE (IN.) 3/8 REFRIGERANT LBS. — R -410A (O.D. UNIT) (9) 7 LBS., 11 OZ FACTORY SUPPLIED YES LINE SIZE — IN. O.D. GAS (h) (1) 7/8 LINE SIZE — IN. O.D. LIQ. 3/8 CHARGING.SPECIFICATIONS SUBCOOLING 8°F DIMENSIONS H X W X D CRATED (IN.) 42 x 35.1 x 38.7 WEIGHT SHIPPING (LBS.) 246 NET {LBS.) 212 4TTR6036J-SUB-1 A-E N (a) Certified in accordance with the Air -Source Unitary Air -conditioner Equipment certification program, which is based on AHRI standard 210/240. (b) Rated In accordance with AHRI standard 270. W Calculated In accordance with Nati. Elec. Codes. Use only HACR circuit breakers or fuses. (d) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current. (e) No means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter. Optional kit shown. (0 Standard Air — Dry Coil — Outdoor (9) This value approximate. For more precise value see unit nameplate. (h) For standard, recommended linear length and lift applications, see the Subcool Charging Chart on page S. For greater lengths and other applications, consult refrigerant piping software Pub. No. 32-3312-xx (xx denotes latest revision). (1) Trane outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit and 15 feet of tested connecting lines. If connecting line length exceeds 15 feet, then final refrigerant charge adjustment is necessary. Each additional foot over 15 feet requires 0.6 lbs of refrigerant. See the Installer's Guide for full charging Instructions. 0 TRANS` Mechanical Specification Options General The Outdoor Units are fully charged from the factory for up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115eF. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 1995. Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather -resistant powder paint finish on all louvered panels and the fan top panel. The corner panels are prepainted. All panels are subjected to our 1,000 hour salt spray test. The base is made of a CMBRG30 weatherproof material to resist corrosion. Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and high pressure switch. High and low pressure controls are inherent to the compressor. A factory supplied liquid line drier is standard. Some models may require field installation. GTRAINE' Compressor The compressor features internal over temperature, pressure protection and total dipped hermetic motor. Other features include: Centrifugal oil pump and low vibration and noise. Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured, this system has a cooling capacity to WE The addition of an evaporator defrost control permits operation to 400E The addition of an evaporator defrost control with TXV permits low ambient cooling to WE Thermostats—Cooling only and heat/cooling (manual and automatic change over). Sub -base to match thermostat and locking thermostat cover. Evaporator Defrost Control — See Low Ambient Cooling. C a US Intertek Trane optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader i creating and sustaining safe, comfortable and energy efficient environments, Trane offers a broad portfolio of advance controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.Trane.com. Trane has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. V2015Trane (## )Ingersoll 01OM2015 l-#■ Ingersoll Rand Supersede. (New) t_i