2020.0259.PR0008 Final_Zoning_Drawings_TCOMM911_Yelm_Water_Tank_09012020TCOMM911 YELM WATER TANK 901 RHOTON RD NW YELM, WA 98597 VICINITY MAP NOT TO SCALE GENERAL LOCATION MAP NOT TO SCALE CONSULTANT GROUP SIGN OFF CONSTRUCTION COORDINATOR DATE SIGNATURE TCOMM911 SIGN OFF DATE SIGNATURE LANDLORD'S REPRESENTATIVE PROJECT MANAGER SITE ACQUISITION COMPLIANCE DEPLOYMENT MANAGER E-911 ENGINEER INTERCONNECT OPERATIONS RF ENGINEER ZONING CONSTRUCTION MANAGER THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO TCOMM911 SERVICES IS STRICTLY PROHIBITED. PROPRIETARY INFORMATION PROJECT CONTACT LIST PROPERTY OWNER: CITY OF YELM 106 2ND ST SE YELM, WA 98597 RF ENGINEER MANAGER SITE ACQUISITION MANAGER INITIAL:Y N REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO EACH REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED POWER/TELCO COORDINATOR FINAL ZONING APPROVAL / SIGN OFF OF FINAL ZONING DRAWINGS PROJECT PROJECT 19-17-2E S2-NE-NW KA LOT 4 SS-8036 25/408 LEGAL DESCRIPTIONPROJECT INFORMATION ZONING CLASSIFICATION: CODE INFORMATION: I (INDUSTRIAL) BUILDING CODE:IBC 2015 CONSTRUCTION TYPE:IIB OCCUPANCY:U, S-2 JURISDICTION:CITY OF YELM PROPOSED BUILDING USE:UNMANNED TELECOM LATITUDE: SITE LOCATION (NAD83): 46° 56' 58.31" N LONGITUDE:122° 36' 05.17" W TOP OF STRUCTURE:485.10' AMSL BASE OF STRUCTURE:332.30' AMSL 2500 SF PROJECT LEASE AREA: 22719210404 PARCEL NUMBER: 7.63 ACRES AREA OF PARCEL: -- SF NEW IMPERVIOUS AREA: 1.PARKING REQUIREMENTS ARE UNCHANGED. 2.TRAFFIC IS UNAFFECTED. 3.SIGNAGE IS UNAFFECTED. GENERAL INFORMATION: UTILITY COMPANIES 152.8' AGL 0.0' AGL (46.949531° N) (122.601436° W) FROM THURSTON 911 COMMUNICATIONS OLYMPIA OFFICE: ·HEAD EAST ON PACIFIC AVE SE TOWARD DEHART DR SE ·TAKE RAMP LEFT FOR I-5 N ·AT EXIT 111, TAKE RAMP RIGHT FOR WA-510 EAST TOWARD MARVIN RD S / YELM ·AT ROUNDABOUT, TAKE 1ST EXIT ONTO QUINAULT DR NE ·TURN RIGHT ONTO WA-510 / MARVIN RD NE ·PASS THROUGH 4 ROUNDABOUTS, REMAINING ON WA-510 ·TURN RIGHT TO STAY ON WA-510 / YELM HWY SE ·BEAR LEFT ONTO 1ST ST N ·ROAD NAME CHANGES TO RHOTON RD SE ·TURN LEFT ONTO 1ST ST NE ·CONTINUE ONTO NW RHOTON RD ·TURN LEFT ·DESTINATION WILL BE ON THE LEFT DRIVING DIRECTIONS TBD TELEPHONE:POWER: PUGET SOUND ENERGY PHONE: (888) 225-5773 TITLE SHEET T-1.0 CITY OF YELM 106 2ND ST YELM, WA 98597 STRUCTURE OWNER: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWINGS ARE SUPERSEDED BY THE LATEST REVISION. LDC TAKES NO RESPONSIBILITY FOR ADEQUACY OF TOWER MOUNTS FOR EXISTING OR PROPOSED LOADING. CONTRACTOR AND MOUNT MANUFACTURER TAKE FULL RESPONSIBILITY FOR MOUNTING PRODUCTS USED & THEIR ADEQUACY. MOUNTS SHOWN IN DRAWINGS ARE FOR ILLUSTRATIVE PURPOSES ONLY. DISCLAIMERS 2015 IBC, STANDARDS AND AMENDMENTS, WAC 51-50 2015 IMC, STANDARDS AND AMENDMENTS, WAC 51-52 2015 IFC, STANDARDS AND AMENDMENTS, WAC 51-54A 2015 UPC, STANDARDS AND AMENDMENTS, WAC 51-56, 51-57 2014 NEC, STANDARDS AND AMENDMENTS, WAC 296-46B 2015 IECC/WASHINGTON STATE ENERGY CODE, WAC 51-11C CODE COMPLIANCEPROJECT DESCRIPTION: TCOMM911 PROPOSES TO CONSTRUCT AN UNMANNED TELECOMMUNICATIONS FACILITY WITH THE ADDITION OF (2) MICROWAVE ANTENNAS, (2) OMNI ANTENNAS, AND (1) TTA UNIT MOUNTED ON AN EXISTING 152.8' WATER TANK; ALSO AN EQUIPMENT SHELTER, 1000 GAL PROPANE TANK AND KOHEL GENERATOR.TCO M M 9- 1-1POLICE ·FIRE ·MEDICAL 9 · 1 · 1 Network Services, LLC SOLUTIONSMOTOROLA SHEET NUMBER SUBMITTALS DATE: DRAWN BY: CHECKED BY: SITE DESCRIPTION BYDATE SHEET TITLE REV YELM WATER TANK 901 RHOTON RD NW YELM, WA 98597 5-28-20 ENS RBH 1 5-28-20 PRELIMINARY ZONING ENS 2 6-11-20 RPZD: ADD SURVEY AAL 3 6-17-20 LEASE EXHIBIT ENS 4 6-23-20 REVISED LEASE EXHIBIT AAL 5 7-18-20 PRELIMINARY ZONING MAZ 6 9-01-20 FINAL ZONING DRAWINGS PPK APPROVAL STAMP www.LDCcorp.com 20210 142nd Avenue NE Woodinville, WA 98072 F 425.482.2893T 425.806.1869 Sur vey ing Engineer ing Pla nn ing Woodinville 1851 Central Pl S, #101 Kent, WA 98030 KentTCOMM9- 1-1POLICE ·FIRE ·MEDICAL 9 · 1 · 1 RICHARD B. HALL STATE OF WASHINGTON 8828 REGISTERED ARCHITECT DRAWING INDEX DWG NO.DESCRIPTION T-1.0 TITLE SHEET G-1.0 GENERAL NOTES G-1.1 GENERAL NOTES & SYMBOLS A-1.0 BOUNDARY PLAN A-1.1 OVERALL SITE PLAN A-1.2 ENLARGED SITE PLAN A-2.0 PROPOSED ENLARGED SITE PLAN A-2.1 PROPOSED ENLARGED ANTENNA PLAN A-3.0 ELEVATION APPLICANT: PROJECT ARCHITECT: LDC, INC. CONTACT: RICHARD B. HALL, AIA PHONE: (425) 806-1869 EMAIL: rhall@ldccorp.com LDC, INC. CONTACT: RICHARD CARDOZA PHONE: (253) 218-9017 EMAIL: rcardoza@ldccorp.com LDC, INC. CONTACT: VINCE TOWNSEND PHONE: (425) 806-1869 EMAIL: vtownsend@ldccorp.com PERMITTING MANAGER: PROJECT SURVEYOR: PROJECT MANAGER: PROJECT CONSULTANT: PYRAMID NETWORK SERVICES 6519 TOWPATH RD EAST SYRACUSE, NY 13507 MOTOROLA SOLUTIONS 3131 ELLIOTT AVE SEATTLE, WA 98121 CONTACT: SEAN GRIER PHONE: (206) 612-0266 CONSTRUCTION MANAGER: THURSTON 911 COMMUNICATION CONTACT: DAVID TAYLOR PHONE: (360) 704-2736 EMAIL: david.taylor@tcomm911.org PYRAMID NETWORK SERVICES CONTACT: JEFF MOCK PHONE: (480) 212-3183 EMAIL: jmock@pyramidns.com THURSTON 911 COMMUNICATIONS CONTACT: KEITH FLEWELLING 2703 PACIFIC AVE SE OLYMPIA, WA 98507 THURSTON 911 COMMUNICATIONS GENERAL NOTES: GENERAL NOTES G-1.0 1. GENERAL 1.1. SUMMARY OF WORK A. THE WORK MAY CONSIST OF, BUT NOT BE LIMITED TO, THE INSTALLATION OF EQUIPMENT ANTENNAS AND LINES, GROUNDING, ELECTRICAL WORK, ETC., ASSOCIATED WITH THE MOTOROLA EQUIPMENT AS INDICATED ON DRAWINGS AND AS SPECIFIED HEREIN. CONTRACTOR SHALL SUPPLY ALL PERMANENT MATERIALS/EQUIPMENT REQUIRED AND ALL LABOR, EQUIPMENT, TOOLS, UTILITIES, MINOR HARDWARE/MATERIALS, TRANSPORTATION AND FACILITIES NECESSARY FOR PROPER EXECUTION AND COMPLETION OF SERVICES AND INSTALL WORK, WHETHER TEMPORARY OR PERMANENT. CONTRACTOR SHALL BE OBLIGATED TO PERFORM ALL THE WORK OUTLINED IN THESE DRAWINGS IN ACCORDANCE WITH THE CONTRACT AGREEMENT, FEDERAL REGULATIONS, STATE REQUIREMENTS, LOCAL CODES, COMMERCIAL/INDUSTRY STANDARDS, DETAILED SCOPE OF WORK AND THE DOCUMENTS IDENTIFIED BELOW. IN CASE OF A CONFLICT BETWEEN THE ABOVE LISTED DOCUMENTS REGARDING STANDARDS OF WORK, THE MORE STRINGENT CRITERIA SHALL APPLY. ANY ADDITIONAL COSTS OR DELAYS RESULTING FROM CORRECTION OF THE WORK TO COMPLY WITH THE ABOVE REQUIREMENT SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 1.2. SITE VISIT CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE ITSELF WITH THE SCOPE OF WORK REQUIRED PER THE DRAWINGS AND ALL LOCAL CONDITIONS AND LAWS AND REGULATIONS THAT MAY IN ANY MANNER AFFECT THE PRICE, PROGRESS AND PERFORMANCE OF WORK, INCLUDING ANY COSTS ASSOCIATED WITH IT. THE CONTRACTOR ALSO VERIFY THAT THE PROJECT CAN BE CONSTRUCTED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS AND NOTIFY THE MOTOROLA REPRESENTATIVE OF ANY DISCREPANCIES OR INTERFERENCES WHICH AFFECT THE WORK OF THIS CONTRACT. 1.3. STANDARDS AND CODES THE FOLLOWING DOCUMENTS (LATEST REVISION, IF APPLICABLE) SHALL BE CONSIDERED TO BE SPECIFICATION AND ARE INCORPORATED HEREIN BY REFERENCE. IN THE EVENT OF CONFLICT BETWEEN THE REQUIREMENTS OF THIS SPECIFICATION AND THE REQUIREMENTS OF THE REFERENCED DOCUMENTS, THE STRICTER SPECIFICATION SHALL GOVERN. WHERE PROVISIONS OF THE CODES AND STANDARDS ARE IN CONFLICT WITH THE BUILDING CODE IN FORCE FOR THIS PROJECT, THE BUILDING CODE SHALL GOVERN. A. AMERICAN CONCRETE INSTITUTE: * ACI 301 - "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS". * ACI 305 "HOT WEATHER CONCRETING". * ACI 306 "COLD WEATHER CONCRETING". * ACI 318 "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE." * ACI 614 "RECOMMENDED PRACTICE FOR MEASURING, MIXING AND PLACING CONCRETE". * ACI 311 "RECOMMENDED PRACTICE FOR CONCRETE INSPECTION". * ACI 315 "MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES". * ACI 613 "RECOMMENDED PRACTICE FOR SELECTING PROPORTIONS FOR CONCRETE". B. AMERICAN NATIONAL STANDARDS INSTITUTE: * ANSI Z359 REQUIREMENTS FOR PERSONAL FALL ARREST SYSTEMS, SUBSYSTEMS AND COMPONENTS * ANSI Z87.1 OCCUPATIONAL AND EDUCATIONAL EYE AND FACE PROTECTION * ANSI Z89.1 PROTECTIVE HEADWEAR FOR INDUSTRIAL WORKERS -REQUIREMENTS * ANSI/IEEE C95.1 SAFETY LEVELS WITH RESPECT TO HUMAN EXPOSURE TO RADIO FREQUENCY ENERGY * ANSI/TLA/EIA STANDARD 222: STRUCTURAL STANDARDS FOR STEEL ANTENNA TOWERS AND ANTENNA SUPPORTING STRUCTURES. C. AMERICAN INSTITUTE OF STEEL CONSTRUCTION" * AISC MANUAL OF THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION: LATEST EDITION D. AMERICAN SOCIETY FOR TESTING AND MATERIALS: * ASTM A615 - "SPECIFICATION FOR DEFORMED AND PLAIN BILLET STEEL BARS FOR CONCRETE REINFORCEMENT". * ASTM C94-80 - "SPECIFICATION FOR READY-MIX CONCRETE". * ASTM C39-77 - "SPECIFICATION FOR TEST FOR COMPREHENSIVE STRENGTH OF CYLINDRICAL CONCRETE SPECIMEN". * ASTM C33 - "SPECIFICATION FOR CONCRETE AGGREGATES". * ASTM C150 - "SPECIFICATION FOR PORTLAND CEMENT". * ASTM C172 - "SAMPLING FRESH CONCRETE". * ASTM C143 - "SLUMP OF PORTLAND CEMENT CONCRETE". * ASTM D698-91 - "TEST METHOD FOR LABORATORY COMPACTION CHARACTERISTICS OF SOIL USING STANDARD EFFORT". * ASTM D1556-64 - "DENSITY OF SOIL IN PLACE BY THE SAND-CONE METHOD". * ASTM D1557 - "TEST FOR MOISTURE-UNIT WEIGHT RELATIONS OF SOILS AND SOIL-AGGREGATE MIXTURES USING 10-LB. HAMMER AND 18-IN. DROP". (PROCEDURE C) * ASTM D2487 - "STANDARD CLASSIFICATION OF SOILS FOR ENGINEERING PURPOSES (UNIFIED SOIL CLASSIFICATION SYSTEM)" * ASTM D2922 - "DENSITY OF SOIL AND SOIL AGGREGATE IN PLACE BY NUCLEAR METHODS SHALLOW DEPTH". * ASTM D2940 - "STANDARD SPECIFICATION FOR GRADED AGGREGATE MATERIAL FOR BASES OR SUB-BASES FOR HIGHWAYS OR AIRPORTS" E. AMERICAN WELDING SOCIETY: * AWS D12.1 - "RECOMMENDED PRACTICES FOR WELDING REINFORCING STEEL, METAL INSERTS AND CONNECTIONS IN REINFORCED CONCRETE CONSTRUCTION". F. CONCRETE REINFORCING STEEL INSTITUTE: * "MANUAL OF STANDARD PRACTICE" G. FEDERAL AVIATION ADMINISTRATION: * DEPARTMENT OF TRANSPORTATION - FEDERAL AVIATION ADMINISTRATION ADVISORY CIRCULAR, AC 70/7460-1G: OBSTRUCTION MARKING AND LIGHTING. * DEPARTMENT OF TRANSPORTATION - FEDERAL AVIATION ADMINISTRATION ADVISORY CIRCULAR, 150-5345-43, FAA/DOD SPECIFICATION L-856: HIGH INTENSITY OBSTRUCTION LIGHTING SYSTEMS. H.FEDERAL COMMUNICATIONS COMMISSION: *FEDERAL COMMUNICATIONS COMMISSION - RULES AND REGULATIONS PART 17: CONSTRUCTION, MARKING AND LIGHTING OF ANTENNA STRUCTURES. I.STRUCTURAL STEEL PAINTING COUNCIL: *SSPC-SP-1-63: SPECIFICATION FOR PAINTING STEEL STRUCTURES. J.MOTOROLA R56 STANDARDS AND GUIDELINES FOR COMMUNICATIONS SITES (LATEST REVISION). K.MOTOROLA'S CIVIL WORKS BID SPECIFICATIONS L.NATIONAL FIRE PROTECTION ASSOCIATION: *NFPA 1 - FIRE PREVENTION CODE *NFPA 70 - NATIONAL ELECTRICAL CODE *NFPA 101 - LIFE SAFETY CODE *NFPA 111 - STANDARD ON STORED ELECTRICAL ENERGY, EMERGENCY AND STANDBY POWER SYSTEMS *NFPA 780 - STANDARD FOR THE INSTALLATION OF LIGHTNING PROTECTION SYSTEMS M.OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION: *OSHA 1926 *OSHA DIRECTIVES CPL 2-1.29 - INTERIM INSPECTION PROCEDURES DURING COMMUNICATION TOWER CONSTRUCTION ACTIVITIES. 1.4.NOTICE TO PROCEED WHEN THE SITE IS READY FOR INSTALLATION, MOTOROLA SHALL ISSUE A NOTICE TO PROCEED TO THE CONTRACTOR. UPON RECEIPT OF THE NOTICE OF PROCEED, THE CONTRACTOR SHALL SUBMIT TO MOTOROLA A SCHEDULE REFLECTING THE WORK PLAN. THE CONTRACTOR SHALL ADVISE THE MOTOROLA REPRESENTATIVE IMMEDIATELY OF ANY SCHEDULE CHANGES. THE CONTRACTOR SHALL ADJUST HIS WORK, AS REQUIRED, TO COORDINATE WITH THE MOTOROLA INSTALLATION TEAM IF THE SCHEDULES OVERLAP DUE TO OTHER CONSTRUCTION ACTIVITIES OCCURING SIMULTANEOUSLY ON THE SITE. THE CONTRACTOR MUST COORDINATE WITH OTHER CONTRACTORS ON THE SITE TO AVOID CONFLICT. DPW TO BE PROVIDED WITH A COPY OF THE CONTRACTOR'S SCHEDULE TO INCORPORATE INTO THE PROJECT SCHEDULE. 1.5.MOTOROLA REPRESENTATIVE MOTOROLA SHALL DESIGNATE A REPRESENTATIVE. THIS PERSON IS THE ONLY CONTACT POINT AUTHORIZED TO MAKE ANY CHANGES TO THE CONTRACT PROVISIONS OR THE PLANS AND SPECIFICATIONS. ANY CHANGES MADE BY THE CONTRACTOR ARE AT THE CONTRACTOR'S RESPONSIBILITY AND RISK. 1.6.CONTRACTORS FIELD REPRESENTATIVE CONTRACTOR SHALL ASSIGN A FIELD REPRESENTATIVE WHO IS FAMILIAR WITH THESE SPECIFICATIONS AND WILL REPRESENT THE CONTRACTOR AND HAVE THE AUTHORITY TO ACT FOR THE CONTRACTOR AND SUPERVISE ALL CONSTRUCTION ACTIVITIES. THE FIELD REPRESENTATIVE SHALL BE AVAILABLE WHEN CONSTRUCTION ACTIVITIES BEGIN. THE FIELD REPRESENTATIVE SHALL BE THE PRIMARY POINT OF CONTACT FOR MOTOROLA DURING THE CONSTRUCTION PHASE OF THE WORK. 1.7.PROJECT MEETINGS THE CONTRACTOR SHALL CONDUCT THE INITIAL (PRE-CONSTRUCTION) MEETING (INCLUDING ALL SUB-CONTRACTORS) WITH THE MOTOROLA REPRESENTATIVE WITHIN TWO WEEKS AFTER AWARD OF THE CONTRACT. SUBSEQUENTLY, THE CONTRACTOR SHALL PROVIDE PROGRESS SCHEDULE UPDATES TO MOTOROLA ON A WEEKLY BASIS. 1.8.MATERIALS CONTRACTOR SHALL FURNISH AND INSTALL ALL MATERIALS AS REQUIRED FOR COMPLETE SYSTEMS INCLUDING: ALL PARTS OBVIOUSLY OR REASONABLY INCIDENTAL TO A COMPLETE INSTALLATION, WHETHER SPECIFICALLY INDICATED OR NOT. ALL SYSTEMS SHALL BE COMPLETELY ASSEMBLED, TESTED, ADJUSTED AND DEMONSTRATED TO BE READY FOR OPERATION PRIOR TO MOTOROLA'S ACCEPTANCE. MATERIALS AND WORKMANSHIP SHALL BE THE BEST OF THEIR RESPECTIVE KINDS (AS DEFINED BY INDUSTRY STANDARDS), FREE OF DEFECTS AND ALL MATERIALS SHALL BE NEW AND UNUSED IN ALL CASES, UNLESS OTHERWISE SPECIFIED. WHERE THE NAME OF A CONCERN OR MANUFACTURER IS MENTIONED ON DRAWINGS OR IN SPECIFICATIONS IN REFERENCE TO A REQUIRED SERVICE OR PRODUCT, AND NO QUALIFICATIONS OR SPECIFICATION OF SUCH IS INCLUDED, THEN THE MATERIAL SPECIFICATIONS, DETAILS OF MANUFACTURE, FINISH, ETC., SHALL BE IN ACCORDANCE WITH MANUFACTURER'S STANDARD PRACTICE, DIRECTION OR SPECIFICATIONS. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO THE MANUFACTURER'S / VENDOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE LOCAL CODES OR ORDINANCES TAKE PRECEDENCE. 1.9.VERIFICATION OF EXISTING CONDITIONS BEFORE STARTING ANY OPERATION, THE CONTRACTOR SHALL EXAMINE EXISTING WORK, OR WORK PERFORMED BY OTHERS, TO WHICH ITS WORK IS TO ADJOIN OR BE APPLIED, AND SHALL REPORT TO MOTOROLA PROJECT MANAGER ANY CONDITIONS THAT WILL PREVENT SATISFACTORY ACCOMPLISHMENT OF HIS WORK. PRIOR TO COMMENCING ANY EXCAVATION OR GRADING, THE CONTRACTOR SHALL SATISFY HIMSELF AS TO THE ACCURACY OF ALL SURVEY DATA AS INDICATED IN THE PLANS AND SPECIFICATIONS AND/OR AS PROVIDED BY MOTOROLA. SHOULD THE CONTRACTOR DISCOVER ANY INACCURACIES, ERRORS, OR OMISSIONS IN THE SURVEY DATA, HE SHALL IMMEDIATELY NOTIFY THE MOTOROLA REPRESENTATIVE IN ORDER THAT PROPER ADJUSTMENTS CAN BE ANTICIPATED AND ORDERED. FAILURE TO NOTIFY THE MOTOROLA REPRESENTATIVE OF DEFICIENCIES, ERRORS OR FAULTS PRIOR TO COMMENCEMENT OF WORK SHALL CONSTITUTE ACCEPTANCE THEREOF AND WAIVER OF ANY CLAIMS OF UNSUITABILITY, ERRORS, OMISSIONS OR INACCURACIES. THE CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, EASEMENTS, ETC. DURING CONSTRUCTION. UPON COMPLETION OF WORK, THE CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY HAVE OCCURRED DUE TO CONSTRUCTION ON OR ABOUT THE PROPERTY. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR PRESERVING ALL ESTABLISHED SURVEY CONTROL POINTS. IF THE CONTRACTOR OR ANY OF HIS SUB-CONTRACTORS MOVE OR DESTROY ANY SURVEY CONTROL POINTS, THE COST INCURRED BY THE LAND OWNER OR MOTOROLA TO RE-ESTABLISH THEM WILL BE BORNE BY THE CONTRACTOR. 2.0. NATIONAL, STATE, AND LOCAL CONSTRUCTION CODES CONTRACTOR SHALL PERFORM ALL WORK AND PROVIDE MATERIALS AND EQUIPMENT AS APPLICABLE IN ACCORDANCE WITH THE LATEST REFERENCED CODES AND STANDARDS OF THE FOLLOWING ORGANIZATIONS: A.AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) B.NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION (NEMA) C.NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) D.UNDERWRITERS LABORATORIES (UL) OR OTHER LISTING ORGANIZATION E.OCCUPATIONAL SAFETY & HEALTH ADMINISTRATION (OSHA) 2.1.ELECTRICAL SYSTEM DESIGN AND INSTALLATION A.NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) #70, #1221, #250, AND #800, MOST RECENT EDITION AS ADOPTED AND AMENDED BY THE AUTHORITY HAVING JURISDICTION (AHJ) AS OF THE DATE OF THE CONTRACT. B.INTERNATIONAL BUILDING CODE (IBC), MOST RECENT EDITION AS ADOPTED AND AMENDED BY THE AHJ AS OF THE DATE OF THE CONTRACT. C.NATIONAL ELECTRICAL CODE (NEC) 708, MOST RECENT EDITION AS ADOPTED AND AMENDED BY THE AHJ AS OF THE DATE OF THE CONTRACT. 1.ALL EXTERIOR GROUND CONDUCTORS INCLUDING GROUND RING SHALL BE #2 AWG SOLID BARE TINNED COPPER. MAKE ALL GROUND CONNECTIONS AS SHORT AND DIRECT AS POSSIBLE. AVOID SHARP BENDS. THE RADIUS OF ANY BEND SHALL NOT BE LESS THAN 8" AND THE INCLUSIVE ANGLE OF ANY BEND SHALL NOT EXCEED 90°. GROUNDING CONDUCTORS SHALL BE ROUTED DOWNWARD TOWARD THE BURIED GROUND RING. 2.ALL BELOW GROUND EXTERNAL CONNECTIONS SHALL BE EXOTHERMICALLY WELDED. ALL EXOTHERMIC WELDS TO BURIED GROUND RING SHALL BE THE PARALLEL-TYPE, EXCEPT FOR THE GROUND RODS WHICH ARE TEE-TYPE EXOTHERMIC WELDS. REPAIR ALL GALVANIZED SURFACES THAT HAVE BEEN DAMAGED BY EXOTHERMIC WELDING. USE SPRAY GALVANIZED SUCH AS HOLUB LECTROSOL #15-501. 3.WHERE MECHANICAL CONNECTORS (TWO-HOLE OR CLAMP) ARE USED, APPLY A LIBERAL PROTECTIVE COATING OF A CONDUCTIVE ANTI-OXIDE COMPOUND ON ALL CONNECTORS. PROVIDE LOCK WASHERS ON ALL MECHANICAL CONNECTORS. USE STAINLESS STEEL HARDWARE THROUGHOUT. THOROUGHLY REMOVE ALL PAINT AND CLEAN ALL DIRT FROM SURFACES REQUIRING GROUND CONNECTORS, REPAINT TO MATCH EXISTING AFTER CONNECTION IS MADE TO MAINTAIN CORROSION RESISTANCE. ALL GROUND CONNECTIONS SHALL BE APPROVED FOR THE TYPES OF METALS BEING ATTACHED TO. 4.THE CONTRACTOR SHALL COORDINATE AS REQUIRED TO HAVE UTILITY COMPANY REPRESENTATIVE AT THE SITE TO DISCONNECT THE UTILITY NEUTRAL FROM GROUNDING SYSTEM DURING FINAL INSPECTION SO THAT REQUIRED TESTING ON THE GROUND SYSTEM CAN BE PERFORMED. THE CONTRACTOR SHALL PROVIDE NOTICE TO THE MOTOROLA REPRESENTATIVE (TWO) DAYS PRIOR TO FINAL TESTING. IF THE CONTRACTOR FAILS TO MAKE UTILITY COMPANY REPRESENTATIVE AVAILABLE DURING THE FINAL TESTING, THE CONTRACTOR SHALL PAY THE COST FOR AN INDEPENDENT GROUNDING CONSULTANT TO PERFORM THE GROUND RESISTANCE TEST. GROUNDING CONSULTANT SHALL BE SELECTED BY THE MOTOROLA REPRESENTATIVE. IF THE UTILITY COMPANY REPRESENTATIVE FAILS TO APPEAR DUE TO NO FAULT THE CONTRACTOR, NO PENALTY APPLY. 5.A RESISTANCE TO GROUND OF (10) OHMS OR LESS IS REQUIRED FOR ALL MOTOROLA SITES. THE CONTRACTOR SHOULD RETAIN HIS OWN TESTER AT HIS OWN EXPENSE. IN ADDITION, A THIRD PARTY SHOULD BE HIRED TO OBTAIN MEGGER AND SWEEP RESULTS ON ALL SITES INCLUSIVE OF WHAT RESULTS THE CONTRACTOR SUBMITS, TO INSURE PROPER QUALITY CONTROL ON ALL SITES. SCHEDULE FINAL MEGGER TEST SUCH THAT THE MOTOROLA REPRESENTATIVE CAN BE PRESENT FOR FIELD VERIFICATION. REFER TO THE MOTOROLA MASTER SPECIFICATION FOR MEGGER TESTING PROCEDURES. IF THE FINAL GROUNDING RESISTANCE MEASUREMENT EXCEEDS 10 (TEN) OHMS, THE CONTRACTOR SHALL NOTIFY THE MOTOROLA REPRESENTATIVE. 6.ALL MOUNTING HARDWARE SHALL BE STAINLESS STEEL. 7.THE GROUND CONDUCTORS SHALL BE RUN STRAIGHT FOR MINIMUM INDUCTANCE AND VOLTAGE DROP. SINCE CABLE BENDS INCREASE INDUCTANCE, THE MINIMUM REQUIRED BENDING RADIUS IS 8 INCHES WHEN BENDS ARE UNAVOIDABLE. ALL METAL WORK WITHIN 10 FEET OF THE GROUND RING SHALL BE DIRECTLY BONDED TO THIS GROUND SYSTEM, WITHOUT USING SERIES OR DAISY CHAIN CONNECTION ARRANGEMENTS. 8.PAINT, ENAMEL, LACQUER AND OTHER ELECTRICALLY NON-CONDUCTIVE COATINGS SHALL BE REMOVED FROM THREADS AND SURFACE AREAS WHERE CONNECTIONS ARE MADE TO ENSURE GOOD ELECTRICAL CONTINUITY. 9.CONNECTIONS BETWEEN DISSIMILAR METALS SHALL NOT BE MADE UNLESS THE CONDUCTORS ARE SEPARATED BY A SUITABLE MATERIAL THAT IS A PART OF THE ATTACHMENT DEVICE LISTED AND APPROVED FOR USE WITH THE SPECIFIC DISSIMILAR METALS MAY BE USED FOR THE PURPOSE. 10.ALL BELOW GRADE GROUND SYSTEM CONDUCTORS SHALL BE A MINIMUM DEPTH OF 30" (OR 6" BELOW THE FROST LINE, WHICHEVER IS GREATER). GENERAL GROUNDING NOTES:Network Services, LLC SOLUTIONSMOTOROLA SHEET NUMBER SUBMITTALS DATE: DRAWN BY: CHECKED BY: SITE DESCRIPTION BYDATE SHEET TITLE REV YELM WATER TANK 901 RHOTON RD NW YELM, WA 98597 5-28-20 ENS RBH 1 5-28-20 PRELIMINARY ZONING ENS 2 6-11-20 RPZD: ADD SURVEY AAL 3 6-17-20 LEASE EXHIBIT ENS 4 6-23-20 REVISED LEASE EXHIBIT AAL 5 7-18-20 PRELIMINARY ZONING MAZ 6 9-01-20 FINAL ZONING DRAWINGS PPK APPROVAL STAMP www.LDCcorp.com 20210 142nd Avenue NE Woodinville, WA 98072 F 425.482.2893T 425.806.1869 Sur vey ing Engineer ing Pla nn ing Woodinville 1851 Central Pl S, #101 Kent, WA 98030 KentTCOMM9- 1-1POLICE ·FIRE ·MEDICAL 9 · 1 · 1 RICHARD B. HALL STATE OF WASHINGTON 8828 REGISTERED ARCHITECT A/C AIR CONDITIONING AGL ABOVE FINISH GRADE APPROX APPROXIMATELY BLDG BUILDING BLK BLOCKING CLG CEILING CLR CLEAR CONC CONCRETE CONST CONSTRUCTION CONT CONTINUOUS DBL DOUBLE DIA DIAMETER DIAG DIAGONAL DN DOWN DET DETAIL DWG DRAWING EA EACH ELEV ELEVATION ELEC ELECTRICAL EQ EQUAL EQUIP EQUIPMENT EXT EXTERIOR FIN FINISH FLUOR FLUORESCENT FLR FLOOR FT FOOT GA GAUGE GALV GALVANIZED GC GENERAL CONTRACTOR GRND GROUND GYP BD GYPSUM WALL BOARD HORZ HORIZONTAL HR HOUR HT HEIGHT HVAC HEATING VENTILATION AIR CONDITIONING IBC INTERNATIONAL BUILDING CODE ID INSIDE DIAMETER IN INCH INFO INFORMATION INSUL INSULATION INT INTERIOR LBS POUNDS MAX MAXIMUM MECH MECHANICAL MTL METAL MFR MANUFACTURE MGR MANAGER MIN MINIMUM MISC MISCELLANEOUS NA NOT APPLICABLE NIC NOT IN CONTRACT NTS NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMETER OSSC OREGON STRUCTURAL SPECIALTY CODE PLYWD PLYWOOD PROJ PROJECT PROP PROPERTY PT PRESSURE TREATED REQ REQUIRED RM ROOM RO ROUGH OPENING SBC SEATTLE BUILDING CODE SHT SHEET SIM SIMILAR SPEC SPECIFICATION SF SQUARE FOOT SS STAINLESS STEEL STL STEEL STRUCT STRUCTURAL STD STUD SUSP SUSPENDED THRU THROUGH TNNG TINNED TYP TYPICAL UNO UNLESS NOTED OTHERWISE VERT VERTICAL VIF VERIFY IN FIELD W/ WITH W/O WITHOUT WP WATER PROOF UNDERGROUND UTILITYUG ANTENNA COAXIAL CABLE CENTERLINELC EXISTING SHEET NUMBER DETAIL NUMBER (E) (P)NEW PROPANE UGT UNDERGROUND TELECO P COAX SYMBOLS AND ABBREVIATIONS: OHT OVERHEAD TELECO UGP UNDERGROUND POWER OHP OVERHEAD POWER GENERAL NOTES: GENERAL NOTES & SYMBOLS G-1.1 1.10. PERMITS THE CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY, MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF THE WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS WHICH MAY BE REQUIRED FOR THE WORK BY THE STATE, COUNTY OR LOCAL GOVERNMENT AUTHORITY. THE WORK PERFORMED ON THE PROJECT AND THE MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. THE CONTRACTOR SHALL MEET ALL OF THE REGULATORY REQUIREMENTS OF THE JURISDICTION GOVERNING CONSTRUCTION. A. LDC TO OBTAIN SEPARATE PERMITS FROM COUNTY FIRE AND EMERGENCY SERVICES. 1. FIRE PERMIT a. FUEL TANKS, GENERATOR AND PIPING b. BATTERIES 2. FIRE SYSTEM PERMIT a. FM200 1.11. SITE INSPECTION BY MOTOROLA THE CONTRACTOR SHALL HAVE THE RESPONSIBILITY FOR ARRANGING WITH MOTOROLA FOR AN INSPECTION PRIOR TO COVERING UP ALL WORK THAT WILL BE COVERED IN FINISHED CONDITION. IT IS THE CONTRACTOR'S RESPONSIBILITY TO MANAGE THE SEQUENCE OF WORK AND REQUEST THE INSPECTIONS IN A TIMELY MANNER. THE CONTRACTOR SHALL NOT REQUEST AN INSPECTION UNLESS ALL OF THE RELATED WORK HAS BEEN COMPLETED. WORK SHALL NOT PROCEED TO THE NEXT STEP UNTIL THE PREVIOUS STEP HAS BEEN INSPECTED AND APPROVED BY THE LOCAL INSPECTORS AND THE MOTOROLA REPRESENTATIVE. THE PRESENCE OF THE OWNER OR MOTOROLA REPRESENTATIVE ON THE JOB SITE IN NO WAY RELIEVES THE CONTRACTOR OF THE ASSOCIATED RESPONSIBILITIES OF THE JOB. ANY WORK WHICH DOES NOT MEET THE REQUIREMENTS OF THE CONTRACT DOCUMENTS WILL BE CORRECTED OR REMOVED SOLELY AT THE CONTRACTOR'S EXPENSE. THE FOLLOWING INFORMATION IS INCLUDED AS A GENERAL GUIDE TO THE CONTRACTOR TO ASSIST IN DETERMINING THE TYPE AND FREQUENCY OF INSPECTIONS. THE LISTED INSPECTIONS REPRESENT THOSE REQUIRED FOR SMALL OR SIMPLE PROJECTS. LARGE OR COMPLEX PROJECTS MAY REQUIRE ADDITIONAL INSPECTIONS DEPENDING ON THE SEQUENCE OF WORK. * FOUNDATIONS EXCAVATION AND REBAR: TO BE MADE AFTER TRENCHES ARE EXCAVATED AND FORMS ERECTED, REINFORCEMENT PLACED, COMPACTION TESTED, SOIL TREATED, VAPOR BARRIER PLACED, AND ESSENTIALLY READY FOR CONCRETE PLACEMENT * GROUNDING: TO BE MADE AFTER THE BELOW GROUND CADWELD CONNECTIONS HAVE BEEN COMPLETED, PRIOR TO COVERING UP THE TRENCHES * ELECTRICAL WORK WITHIN WALLS: TO BE MADE AFTER THE ROOF, FRAMING, FIREBLOCKING AND BRACING IS IN PLACE PRIOR TO THE INSTALLATION OF INSULATION OR WALL/CEILING MEMBRANES. AS A GENERAL RULE, THE CONTRACTOR SHALL PROVIDE ADVANCE NOTICE TO MOTOROLA FOR INSPECTION OF ALL WORK PRIOR TO CONCEALMENT. THE CONTRACTOR HAS RESPONSIBILITIES RELATIVE TO ALL TYPES OF INSPECTIONS AND IS RESPONSIBLE FOR CONTACTING ALL OF THE INSPECTING ENTITIES TO DETERMINE HIS RESPONSIBILITIES. ALL OF THESE INSPECTING ENTITIES HAVE UNIQUE AND SEPARATE RESPONSIBILITIES. ONE INSPECTION FROM AN ENTITY WILL NOT SUBSTITUTE FOR AN INSPECTION FROM ANOTHER ENTITY. CONTRACTOR IS RESPONSIBLE FOR ALL SCHEDULING & COORDINATION OF ALL INSPECTIONS REQUIRED BY CODE/PERMIT. 1.12. SAFETY THE CONTRACTOR, HIS EMPLOYEES, ANY SUB-CONTRACTORS, VENDORS, THEIR RESPECTIVE EMPLOYEES AND CONTRACTOR'S VISITORS SHALL COMPLY WITH ALL SAFETY STANDARDS, ACCIDENT PREVENTION REGULATIONS AND ENVIRONMENTAL REGULATIONS PROMULGATED BY FEDERAL, STATE OR LOCAL AUTHORITIES HAVING JURISDICTION AND SHALL AT ALL TIMES CONDUCT ALL OPERATIONS UNDER THE CONTRACT IN A MANNER TO AVOID THE RISK OF BODILY HARM TO ANY PERSONS AND THE RISK OF DAMAGE TO ANY PROPERTY, EQUIPMENT OR MATERIAL. SUCH PARTIES SHALL ALSO COMPLY WITH ANY SAFETY PROGRAMS AND/OR RULES PROMULGATED BY OWNER AND/OR MOTOROLA. 1.13. ELECTRO MAGNETIC EMISSIONS THE CONTRACTOR SHALL ACKNOWLEDGE ALL OR PORTIONS OF THE WORK MAY INVOLVE POSSIBLE EXPOSURE OF CONTRACTOR, SUB-CONTRACTORS, AND THEIR RESPECTIVE EMPLOYEES, AGENTS, INVITEES, LICENSEES AND OTHER VISITORS TO THE JOBSITE AND/OR MOTOROLA PREMISES TO ELECTRO-MAGNETIC ENERGY ("EME") WHILE PERFORMING WORK UNDER THIS CONTRACT, ESPECIALLY IF WORK IS PERFORMED ON EXISTING ANTENNA TOWERS OR BUILDING TOPS WHERE ANTENNAS ARE LOCATED. THE CONTRACTOR REPRESENTS THAT CONTRACTOR, SUBCONTRACTORS, AND ALL OF THEIR RESPECTIVE EMPLOYEES, AGENTS, INVITEES, LICENSEES, AND OTHER AUTHORIZED REPRESENTATIVES WHO ARE PERFORMING SERVICES UNDER THIS AGREEMENT WILL COMPLY WITH ALL ANSI AND ANY OTHER APPLICABLE EME STANDARDS, RULES OR REGULATIONS, INCLUDING, BUT NOT LIMITED TO THOSE RULES OR REGULATIONS IMPOSED OR SUGGESTED BY MOTOROLA, IF ANY. THE CONTRACTOR SHALL ADHERE TO ALL OSHA RULES, REGULATIONS AND ADOPTED POLICIES. ALL CONTRACTOR PERSONNEL SHALL HAVE UNDERGONE ELECTROMAGNETIC ENERGY (EME) TRAINING FOR PERSONNEL WORKING IN THE VICINITY OF ACTIVE ANTENNAS. AS SUCH IT IS RECOMMENDED THAT RF MONITORS BE USED BY THE TOWER PERSONNEL TO MONITOR EXPOSURE LEVELS. IF EME LEVELS AT THE SITE EXCEED THE MAXIMUM PERMISSIBLE EXPOSURE LIMITS, THE CONTRACTOR SHALL COORDINATE WITH THE INDIVIDUALS RESPONSIBLE FOR USE OF THE TRANSMITTER TO MAKE SURE THAT THE EQUIPMENT IS DEACTIVATED BEFORE WORK CAN BE RESUMED, WITHOUT CAUSING A SERIOUS DISRUPTION OF THE SERVICE. 1.14. SITE CLEANUP THE CONTRACTOR SHALL KEEP THE GENERAL WORK AREA CLEAN AND HAZARD FREE DURING CONSTRUCTION AND DISPOSE OF ALL DIRT, DEBRIS, VEGETATION, AND RUBBISH, AND REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY. WHENEVER THE WORK-SITE IS LEFT UNATTENDED, THE CONTRACTOR SHALL BLOCK THE OPENING WITH WARNING TAPE TO DISCOURAGE TRESPASSING. THE PREMISES SHALL BE LEFT IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE AT THE CONCLUSION OF SITE WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LANDSCAPE GRADING AND SEEDING OF THE DISTURBED SOIL. THE CONTRACTOR SHALL USE LOCAL GRASS SEED TO STABILIZE SOIL AND SHALL COVER DISTURBED AREAS WITH HAY MULCH TO REDUCE RUNOFF OF SEDIMENT TO DOWNSTREAM AREAS. THE CONTRACTOR SHALL RESTORE THE SITE TO ITS ORIGINAL CONDITION. ALL SLOPES AND DISTURBED AREAS NOT RECEIVING AGGREGATE SURFACING ARE TO BE PREPARED AND BROADCAST SEEDED AND FERTILIZED FOR EROSION PROTECTION. SEEDING FOR AREAS DISTURBED SHALL BE ESTABLISHED SEASONALLY AS REQUIRED BY LOCAL CODES. THE CONTRACTOR SHALL EXERCISE ALL CARE TO AVOID DAMAGE OR INTERRUPTION OF EXISTING UNDERGROUND OR OVERHEAD ELECTRIC SERVICES, UNDERGROUND GROUNDING AND FUEL LINES, EQUIPMENT AND BUILDINGS ON THE SITE, PLUS OFF SITE SERVICES, BURIED OR OVERHEAD, SURROUNDING THE EXISTING OR EXPANDED COMPOUND. ANY PROPERTY DAMAGE CAUSED BY THE CONTRACTOR OR HIS OPERATIONS SHALL BE CORRECTED AND/OR RESTORED TO THE SATISFACTION OF THE PROPERTY OWNER(S) AND MOTOROLA AT NO ADDITIONAL COST TO THE PROPERTY OWNER OR MOTOROLA. BURNING WILL NOT BE PERMITED. 1.15.FACILITY STARTUP & COMMISSIONING THE CONTRACTOR AND/OR SUB-CONTRACTORS SHALL DEMONSTRATE TO MOTOROLA THAT ALL SYSTEMS AND SUB-SYSTEMS INSTALLED UNDER THIS CONTRACT, OPERATE PROPERLY PRIOR TO THE FINAL ACCEPTANCE INSPECTION. PROVIDE THE OPERATIONS AND MAINTENANCE MANUALS AT THIS TIME. DPW TO RECEIVE PAPER & ELECTRONIC COPIES OF ALL DESIGN & AS-BUILT (RECORD) DRAWINGS. 1.16.SHOP DRAWINGS/AS-BUILT DRAWINGS THE MODIFICATIONS TO THE DRAWINGS AFTER CONSTRUCTION START SHALL RECEIVE ENGINEERING & MOTOROLA APPROVAL PRIOR TO ANY CHANGES BEING MADE. THE ENGINEER OF RECORD SHALL MAKE THE REQUIRED CHANGE AND WILL SUBMIT CHANGES TO MOTOROLA AND ANY JURISDICTION HAVING AUTHORITY. THE CONTRACTOR SHALL KEEP UP-TO-DATE MARKED-UP PRINTS OF THE PROJECT DRAWINGS. UPON COMPLETION OF WORK AT THE SITE, THE CONTRACTOR SHALL REVIEW THE COMPLETED AS-BUILT DRAWINGS, AND ASCERTAIN THAT ALL DATA FURNISHED ON THE DRAWINGS IS ACCURATE AND TRULY REPRESENTS THE WORK AS ACTUALLY INSTALLED. MARKINGS INDICATING CHANGES TO THE DRAWINGS SHALL BE RED OR GREEN AND CLEARLY VISIBLE. TWO (2) SETS OF "AS-BUILT" DRAWINGS SHALL BE FURNISHED TO THE MOTOROLA REPRESENTATIVE AT THE COMPLETION OF THE PROJECT. THESE DRAWINGS SHALL ALSO SHOW THE FOLLOWING: *MODIFICATIONS TO SITE LAYOUT. *GROUNDING SYSTEM LAYOUT. *UNDERGROUND FUEL LINE RUN. *UNDERGROUND TELCO CABLE RUN. *UNDERGROUND ELECTRICAL RUN. WHERE THE CONTRACTOR IS RESPONSIBLE FOR SUPPLYING THE SITE EQUIPMENT (SHELTER, ISOLATION TRANSFORMER, GENERATOR, ETC.) THAT REQUIRES PERIODIC MAINTENANCE, THE CONTRACTOR SHALL INCLUDE ALL OPERATION AND MAINTENANCE MANUALS AND ALL AS-BUILT DRAWINGS WHICH FULLY DESCRIBE THE ACTUAL INSTALLED EQUIPMENT. 1.1.TEST PROCEDURES AND RESULTS THE CONTRACTOR IS REQUIRED TO SUBMIT THE RESULTS OF ALL TESTS REQUIRED BY THE PROJECT SPECIFICATIONS AND DRAWINGS THAT FALL WITHIN HIS SCOPE OF WORK TO THE ENGINEER OF RECORD W/COPIES TO MOTOROLA WITHIN FIVE (5) DAYS OF THE TEST. THE CONTRACTOR IS REQUIRED TO SUBMIT TEST PROCEDURES NINETY (90) DAYS PRIOR TO THE TESTS BEING CONDUCTED. IN GENERAL, THE CONTRACTOR SHALL SUBMIT THE FOLLOWING TEST RESULTS: *MIX DESIGN/CONCRETE COMPRESSION TEST FOR ALL CONCRETE WORK. *TDR IS NOT ACCEPTABLE TO MSI. THE LINES MUST BE TESTED USING A FREQUENCY DOMAIN REFLECTOMETER (FDR) / SWEEP TEST FOR ANTENNA AND TRANSMISSION LINE. AN ST FROM MSI MUST BE PRESENT FOR THIS TESTING. SEE R56 2017 SECTION 9.10.12. INSTALLATION WORK SHALL COMPLY WITH R56 2017 SECTION 9.10.11.2. *FUEL LINE LEAKAGE TEST FOR FUEL TANK AND PIPING INSTALLATION WORK. *SLUMP TEST FOR CONCRETE WORK. *GROUNDING RESISTANCE TEST FOR GROUNDING WORK. *STRUCTURAL STEEL FABRICATION DRAWINGS *ANY OTHER TEST THAT MAY BE REQUIRED. 1.1.CONTRACT CLOSEOUT-IN ACCORDANCE WITH MOTOROLA'S SUBCONTRACT AGREEMENT TERMS AND CONDITIONS THE MOTOROLA REPRESENTATIVE WILL PROVIDE A CERTIFICATE OF COMPLETION AND APPROVE FINAL PAYMENT WHEN ALL PUNCH-LIST ITEMS HAVE BEEN CORRECTED AND ALL SYSTEMS ARE ACCEPTABLE. AFTER FINAL PAYMENT, CONTRACTOR WILL SIGN A RELEASE OF LIEN. 1.2.WARRANTY ALL WORK PERFORMED BY THE CONTRACTOR IN COMPLETING THE SCOPE IDENTIFIED ON THE DRAWINGS SHALL BE GUARANTEED BY THE CONTRACTOR FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL COMPLETION OF THE PROJECT. THIS GUARANTEE SHALL COVER ALL MATERIALS, EQUIPMENT OR WORKMANSHIP WHICH IN THE OPINION OF MOTOROLA IS RENDERED DEFECTIVE OR INFERIOR OR NOT IN ACCORDANCE WITH THE TERMS OF THE CONTRACT DURING THE GUARANTEE PERIOD. IF, WITHIN THE GUARANTEE PERIOD, REPAIRS OR CHANGES ARE REQUIRED TO CORRECT THE GUARANTEE WORK, THEN UPON RECEIPT OF NOTICE, THE CONTRACTOR SHALL PROMPTLY AND WITHOUT EXPENSE TO MOTOROLA OR THE COUNTY, PROCEED TO: *PLACE IN SATISFACTORY CONDITION ALL OF SUCH GUARANTEED WORK AND CORRECT ALL DEFECTS THEREIN. *MAKE GOOD ALL DAMAGES TO THE STRUCTURE OR SITE OR EQUIPMENT OR CONTENTS THEREOF, WHICH, IN THE OPINION OF THE MOTOROLA, IS THE RESULT OF THE USE OF MATERIALS, EQUIPMENT, OR WORKMANSHIP WHICH ARE INFERIOR, DEFECTIVE, OR NOT IN ACCORDANCE WITH THE TERMS OF THE CONTRACT; *MAKE GOOD ANY WORK, MATERIALS OR EQUIPMENT, AND ADJACENT STRUCTURES DISTURBED IN FULFILLING THE GUARANTEE. 1.1.RELATED DOCUMENTS CONTRACTOR SHALL BECOME FAMILIAR WITH THE INFORMATION AND REQUIREMENTS CONTAINED IN THE FOLLOWING DOCUMENTS RELATED TO THE PROJECT: A.R-56 STANDARDS AND GUIDELINES FOR COMMUNICATIONS SITES BY MOTOROLA. B.ALL OTHER PERTINENT DOCUMENTS SITE PLAN APPROVAL APPROVAL OF THESE PLANS IS FOR CONSTRUCTION OF ROAD AND DRAINAGE IMPROVEMENTS, SITE DRAINAGE & GRADING AND TEMPORARY EROSION CONTROL IN UNINCORPORATED THURSTON COUNTY ONLY. THESE PLANS DO NOT AUTHORIZE ANY OTHER UTILITY APPROVAL OR IMPROVEMENTS PROPOSED IN ANY STATE RIGHT OF WAY. SITE PLAN APPROVAL IS VOID IF THE COMMERCIAL BUILDING PERMIT HAS NOT BEEN OBTAINED OR RENEWED WITHIN TWO YEARS OF APPROVAL. SUBDIVISION PLAN APPROVAL IS VOID IF THE FINAL PLAT IS NOT RECORDED PRIOR TO THE PRELIMINARY PLAT APPROVAL EXPIRATION. X X-X.X Network Services, LLC SOLUTIONSMOTOROLA SHEET NUMBER SUBMITTALS DATE: DRAWN BY: CHECKED BY: SITE DESCRIPTION BYDATE SHEET TITLE REV YELM WATER TANK 901 RHOTON RD NW YELM, WA 98597 5-28-20 ENS RBH 1 5-28-20 PRELIMINARY ZONING ENS 2 6-11-20 RPZD: ADD SURVEY AAL 3 6-17-20 LEASE EXHIBIT ENS 4 6-23-20 REVISED LEASE EXHIBIT AAL 5 7-18-20 PRELIMINARY ZONING MAZ 6 9-01-20 FINAL ZONING DRAWINGS PPK APPROVAL STAMP www.LDCcorp.com 20210 142nd Avenue NE Woodinville, WA 98072 F 425.482.2893T 425.806.1869 Sur vey ing Engineer ing Pla nn ing Woodinville 1851 Central Pl S, #101 Kent, WA 98030 KentTCOMM9- 1-1POLICE ·FIRE ·MEDICAL 9 · 1 · 1 RICHARD B. HALL STATE OF WASHINGTON 8828 REGISTERED ARCHITECT PROPERTY LINES AND STRUCTURES HAVE BEEN DIGITIZED FROM PREVIOUS PLAN SETS OR FROM ASSESSORS MAPS. LDC HAS NOT COMPLETED A SITE SURVEY AND THEREFORE MAKES NO CLAIM AS TO THE ACCURACY OF INFORMATION DEPICTED ON THIS SHEET. 1BOUNDARY PLAN 22"x34" SCALE: 1" = 40'11"x17" SCALE: 1" = 80'' BOUNDARY PLAN A-1.0 PROJECT I PROPOSED TCOMM911 12'x24' EQUIPMENT SHELTER PROPOSED QUANTITIES POWER LENGTH: TBD FIBER/TELCO LENGTH:TBD ROAD LENGTH:TBD UNDERGROUND: OVERHEAD:TBD ZONING MAP NOT TO SCALE ZONING: I (INDUSTRIAL) ADJACENT ZONING: Network Services, LLC SOLUTIONSMOTOROLA SHEET NUMBER SUBMITTALS DATE: DRAWN BY: CHECKED BY: SITE DESCRIPTION BYDATE SHEET TITLE REV YELM WATER TANK 901 RHOTON RD NW YELM, WA 98597 5-28-20 ENS RBH 1 5-28-20 PRELIMINARY ZONING ENS 2 6-11-20 RPZD: ADD SURVEY AAL 3 6-17-20 LEASE EXHIBIT ENS 4 6-23-20 REVISED LEASE EXHIBIT AAL 5 7-18-20 PRELIMINARY ZONING MAZ 6 9-01-20 FINAL ZONING DRAWINGS PPK APPROVAL STAMP www.LDCcorp.com 20210 142nd Avenue NE Woodinville, WA 98072 F 425.482.2893T 425.806.1869 Sur vey ing Engineer ing Pla nn ing Woodinville 1851 Central Pl S, #101 Kent, WA 98030 KentTCOMM9- 1-1POLICE ·FIRE ·MEDICAL 9 · 1 · 1 RICHARD B. HALL STATE OF WASHINGTON 8828 REGISTERED ARCHITECT R-6 (MODERATE DENSITY RESIDENTIAL) ADJACENT ZONING: I (INDUSTRIAL) ADJACENT ZONING: I (INDUSTRIAL) R-6 R-6 R-6 ID LI 428'-0"± WATER TANK SETBACK 201'-0"± WATER TANK SETBACK159'-0"± WATER TANK SETBACK287'-0"± WATER TANK SETBACKEXISTING SITE ACCESS 1 A-1.1 PROPOSED TCOMM911 ANTENNAS MOUNTED ON AN EXISTING 152.8' WATER TANK PROPOSED TCOMM911 LEASE AREA RHOTON ROADGRAVE L P A R K I N G A R E A GRASS GRASS GRASS GRASS GATEPAD MOUNTED TRANSFORMER GENERATOR ON CONCRETE PAD TELEPHONE PEDESTAL CCTV PEDESTAL HANDHOLE IRRIGATION CONTROL VALVES WHEEL STOP (TYPICAL) GRAVEL ROADWAY GRAVEL SIGN TANK SUPPORT LEG ON CONCRETE FOOTING (TYPICAL)GATEASPHALT DRIVEWAY WATER, BURIED POWER AND TELEPHONE PAINTED LOCATES VERTICAL PIPE DRAIN POWER OUTLET AT EDGE OF FOOTING GRASS GRASS GRASS GRASS & GRAVE L GRASS & GRAVE L VERTICAL PVC PIPE FLAG POLE POWER OUTLET AT EDGE OF FOOTING APPROXIMATE FLOOD ZONE DELINEATION LINE SCALED FROM FEMA FIRMETTE SET HUB (TYPICAL) WATER TANK (TO REMAIN) OVERALL SITE PLAN A-1.11OVERALL SITE PLAN 22"x34" SCALE: 1/16" = 1'-0" Network Services, LLC SOLUTIONSMOTOROLA SHEET NUMBER SUBMITTALS DATE: DRAWN BY: CHECKED BY: SITE DESCRIPTION BYDATE SHEET TITLE REV YELM WATER TANK 901 RHOTON RD NW YELM, WA 98597 5-28-20 ENS RBH 1 5-28-20 PRELIMINARY ZONING ENS 2 6-11-20 RPZD: ADD SURVEY AAL 3 6-17-20 LEASE EXHIBIT ENS 4 6-23-20 REVISED LEASE EXHIBIT AAL 5 7-18-20 PRELIMINARY ZONING MAZ 6 9-01-20 FINAL ZONING DRAWINGS PPK APPROVAL STAMP www.LDCcorp.com 20210 142nd Avenue NE Woodinville, WA 98072 F 425.482.2893T 425.806.1869 Sur vey ing Engineer ing Pla nn ing Woodinville 1851 Central Pl S, #101 Kent, WA 98030 KentTCOMM9- 1-1POLICE ·FIRE ·MEDICAL 9 · 1 · 1 RICHARD B. HALL STATE OF WASHINGTON 8828 REGISTERED ARCHITECT EXISTING SITE ACCESS ROAD EXISTING TREES, TYP (TO REMAIN) EXISTING SITE ACCESS GATE 1 A-1.2 PROPOSED TCOMM911 ELECTRICAL SERVICE ORIGINATING FROM AN EXISTING 480Y/277, PSE XFRM (559640/147526) AND CONTINUING VIA BURIED CONDUIT WITHIN UNDERGROUND TRENCH TO TCOMM911 EQUIPMENT SHELTER (WITH POSSIBLE 25KVA STEP-DOWN TRANSFORMER LOCATED WITHIN SHELTER) DELIVERING 200A, 120/240 1PH, SERVICE TO DISCONNECT AND DISTRIBUTION PROPOSED TCOMM911 ANTENNAS MOUNTED ON EXISTING WATER RESERVOIR WITH THE ADDITION OF GROUND EQUIPMENT 11"x17" SCALE: 1/32" = 1'-0" PROPOSED TCOMM911 25'-0" SETBACK FROM ALL IGNITION SOURCES, BUILDINGS, & PROPERTY LINES 142'-0" ANTENNA SETBACK ENLARGED SITE PLAN A-1.21ENLARGED SITE PLAN 22"x34" SCALE: 1/8" = 1'-0" Network Services, LLC SOLUTIONSMOTOROLA SHEET NUMBER SUBMITTALS DATE: DRAWN BY: CHECKED BY: SITE DESCRIPTION BYDATE SHEET TITLE REV YELM WATER TANK 901 RHOTON RD NW YELM, WA 98597 5-28-20 ENS RBH 1 5-28-20 PRELIMINARY ZONING ENS 2 6-11-20 RPZD: ADD SURVEY AAL 3 6-17-20 LEASE EXHIBIT ENS 4 6-23-20 REVISED LEASE EXHIBIT AAL 5 7-18-20 PRELIMINARY ZONING MAZ 6 9-01-20 FINAL ZONING DRAWINGS PPK APPROVAL STAMP www.LDCcorp.com 20210 142nd Avenue NE Woodinville, WA 98072 F 425.482.2893T 425.806.1869 Sur vey ing Engineer ing Pla nn ing Woodinville 1851 Central Pl S, #101 Kent, WA 98030 KentTCOMM9- 1-1POLICE ·FIRE ·MEDICAL 9 · 1 · 1 RICHARD B. HALL STATE OF WASHINGTON 8828 REGISTERED ARCHITECT PROPOSED TCOMM911 90"x33"x47" 35kW GAS (LIQUID PROPANE FUELED) KOHLER STANDBY GENERATOR ANCHORED TO 5'x10' CONCRETE PAD ELEVATED 24" ABOVE GRADE (COMPLIANT WITH FEMA FLOOD PLAIN REQUIREMENTS) PROPOSED TCOMM911 MICROWAVE ANTENNAS MOUNTED ON AN EXISTING 152.8' WATER TANK PROPOSED TCOMM911 11'-8"x24' MOTOROLA MSB EQUIPMENT SHELTER ANCHORED TO CONCRETE SLAB OVER STEM WALL FOUNDATION ELEVATED 24" ABOVE GRADE (COMPLIANT WITH FEMA FLOOD PLAIN REQUIREMENTS) PROPOSED TCOMM911 1,000 GAL LIQUID FUEL TANK MOUNTED ON A (6'X17') CONCRETE PAD ELEVATED 24" ABOVE GRADE (COMPLIANT WITH FEMA FLOOD PLAIN REQUIREMENTS) PROPOSED TCOMM911 LEASE AREA PROPOSED TCOMM911 OMNI ANTENNAS MOUNTED ON AN EXISTING 152.8' WATER TANK 1 2 3 4 5 6 EXISTING DF DRIP LINE/ ROOT SYSTEM EXISTING DF DRIP LINE/ ROOT SYSTEM PROPOSED TCOMM911 (5) 7/8Ø,(1) 1/2"Ø,(2)3/8"Ø COAX CABLE ROUTED TO OMNI ANTENNAS, TTA & MW ANTENNAS VIA ICE BRIDGE & CABLE LADDER 11"x17" SCALE: 1/16" = 1'-0" 11'-8"24'-0"10'-6"5'-0"25'-4"23'-9"6'-0" PROPOSED TCOMM911 25'-0" SETBACK FROM ALL IGNITION SOURCES, BUILDINGS, & PROPERTY LINES 17'-0"28'-10"24'-6" 4'-6"4'-6"TYPPROPOSED ARBORVITAE SCREEN (9 TOTAL, ACTUAL LOCATION TBD) 1 A-2.0 1 A-2.1 PROPOSED ENLARGED SITE PLAN A-2.01PROPOSED ENLARGED SITE PLAN 22"x34" SCALE: 1/4" = 1'-0"11"x17" SCALE: 1/8" = 1'-0" ·OTHER CARRIER ANTENNA ARRAY(S) NOT SHOWN FOR CLARITY ·PROPOSED MICROWAVE ICE SHIELDS NOT SHOWN FOR CLARITY ·ALL CONSTRUCTION SHALL BE DONE IN ACCORDANCE WITH MOTOROLA'S R-56 DESIGN STANDARDS NOTE: Network Services, LLC SOLUTIONSMOTOROLA SHEET NUMBER SUBMITTALS DATE: DRAWN BY: CHECKED BY: SITE DESCRIPTION BYDATE SHEET TITLE REV YELM WATER TANK 901 RHOTON RD NW YELM, WA 98597 5-28-20 ENS RBH 1 5-28-20 PRELIMINARY ZONING ENS 2 6-11-20 RPZD: ADD SURVEY AAL 3 6-17-20 LEASE EXHIBIT ENS 4 6-23-20 REVISED LEASE EXHIBIT AAL 5 7-18-20 PRELIMINARY ZONING MAZ 6 9-01-20 FINAL ZONING DRAWINGS PPK APPROVAL STAMP www.LDCcorp.com 20210 142nd Avenue NE Woodinville, WA 98072 F 425.482.2893T 425.806.1869 Sur vey ing Engineer ing Pla nn ing Woodinville 1851 Central Pl S, #101 Kent, WA 98030 KentTCOMM9- 1-1POLICE ·FIRE ·MEDICAL 9 · 1 · 1 RICHARD B. HALL STATE OF WASHINGTON 8828 REGISTERED ARCHITECT PROPOSED TCOMM911 10'-0" TALL PEDESTAL MOUNTED ICE BRIDGE W/ 8'-0" CLEAR BELOW COAX SUPPORT. SITE TO BE FILLED WITH 6" OF 3/4"Ø CRUSHED ROCK W/ WEED BARRIER ON 95% COMPACTED FILL. PROPOSED TCOMM911 90"x33"x47" 35Kw GAS (LIQUID PROPANE FUELED) KOHLER STANDBY GENERATOR ANCHORED TO 5'x10' CONCRETE PAD. PROPOSED TCOMM911 1000 GAL LP TANK ANCHORED TO RAISED CONCRETE SLAB ABOVE FLOOD PLANE.. STRUCTURAL PENDING. PROPOSED TCOMM911 (5'x5') 3-STEP CONCRETE STOOP WITH ACCESS RAISED ABOVE FLOOD PLANE (1 TOTAL). PROPOSED TCOMM911 EQUIPMENT SHELTER ANCHORED TO RAISED CONCRETE SLAB ABOVE FLOOD PLANE. STRUCTURAL PENDING. SEE SITE NOTES FOR PROPOSED COAX SIZE AND QUANTITY PROPOSED TCOMM911 ARBORVITAE SCREEN (9 TOTAL, ACTUAL LOCATION TBD). 3 5 8 15 22 23 31 32 1.VERIFY ANTENNA MODEL, TIP HEIGHT & AZIMUTHS. 2.ANALYSIS OF TOWER & FOUNDATION SHALL BE PERFORMED BY LDC & STAMPED BY A LICENSED STRUCTURAL ENGINEER. 3.(1) 7/8"Ø COAX FEEDERS FOR EACH 700MHz Rx ANTENNA 4.(1) 7/8"Ø COAX FEEDERS FOR EACH 700MHz Tx ANTENNA 5.(1) 1/2"Ø COAX FOR EACH TTA 6.(2) 3/8"Ø COAX FOR EACH MICROWAVE ANTENNA SITE NOTES CONSTRUCTION PLAN KEYED NOTES 33215 8 EXISTING TREE (TYP, TO REMAIN)PROPOSED TCOMM911 11'-8"EQUIPMENT SHELTERPROPOSED TCOMM911 24'-0" EQUIPMENT SHELTER 3 310'-6"5'-0"10'-0"22 17'-0"6'-0"PROPOSED TCOMM911 25'-0" SETBACK FROM ALL IGNITION SOURCES, BUILDINGS, & PROPERTY LINES 32 23 5'-0"5'-0" 5 5'-0"5'-0"5'-0"5'-0"5'-2"2'-7" 1'-11" 4'-6" 4'-0" 6" 4'-6"4'-6"4'-6"4'-6"5'-6"4'-6"5 5 10" 10" 31 TANK SUPPORT LEGON CONCRETE FOOTING(TYPICAL)POWER OUTLET ATEDGE OF FOOTINGGRASSPOWER OUTLET ATEDGE OF FOOTINGWATER TANKPROPOSED ENLARGED ANTENNA PLAN A-2.11PROPOSED ENLARGED ANTENNA PLAN 22"x34" SCALE: 3/16" = 1'-0"11"x17" SCALE: 3/32" = 1'-0" ·OTHER CARRIER ANTENNA ARRAY(S) NOT SHOWN FOR CLARITY ·PROPOSED MICROWAVE ICE SHIELDS NOT SHOWN FOR CLARITY ·ALL CONSTRUCTION SHALL BE DONE IN ACCORDANCE WITH MOTOROLA'S R-56 DESIGN STANDARDS NOTE: Network Services, LLC SOLUTIONSMOTOROLA SHEET NUMBER SUBMITTALS DATE: DRAWN BY: CHECKED BY: SITE DESCRIPTION BYDATE SHEET TITLE REV YELM WATER TANK 901 RHOTON RD NW YELM, WA 98597 5-28-20 ENS RBH 1 5-28-20 PRELIMINARY ZONING ENS 2 6-11-20 RPZD: ADD SURVEY AAL 3 6-17-20 LEASE EXHIBIT ENS 4 6-23-20 REVISED LEASE EXHIBIT AAL 5 7-18-20 PRELIMINARY ZONING MAZ 6 9-01-20 FINAL ZONING DRAWINGS PPK APPROVAL STAMP www.LDCcorp.com 20210 142nd Avenue NE Woodinville, WA 98072 F 425.482.2893T 425.806.1869 Sur vey ing Engineer ing Pla nn ing Woodinville 1851 Central Pl S, #101 Kent, WA 98030 KentTCOMM9- 1-1POLICE ·FIRE ·MEDICAL 9 · 1 · 1 RICHARD B. HALL STATE OF WASHINGTON 8828 REGISTERED ARCHITECT PROPOSED TCOMM911 CABLE LADDER. PROPOSED TCOMM911 10'-0" TALL PEDESTAL MOUNTED ICE BRIDGE W/ 8'-0" CLEAR BELOW COAX SUPPORT. PROPOSED TCOMM911 MAGNET ANTENNA MOUNT (4 TOTAL). PROPOSED TCOMM911 OMNI ANTENNA, TYP (2 TOTAL). PROPOSED TCOMM911 TTA UNIT (1 TOTAL). PROPOSED TCOMM911 MICROWAVE WITH MOUNT (2 TOTAL). EXISTING 152.8' WATER TANK. SEE SITE NOTES FOR PROPOSED COAX SIZE AND QUANTITY PROPOSED TCOMM911 ARBORVITAE SCREEN (9 TOTAL, ACTUAL LOCATION TBD). 4 6 11 12 13 15 16 31 32 1.VERIFY ANTENNA MODEL, TIP HEIGHT & AZIMUTHS. 2.ANALYSIS OF TOWER & FOUNDATION SHALL BE PERFORMED BY LDC & STAMPED BY A LICENSED STRUCTURAL ENGINEER. 3.(1) 7/8"Ø COAX FEEDERS FOR EACH 700MHz Rx ANTENNA 4.(1) 7/8"Ø COAX FEEDERS FOR EACH 700MHz Tx ANTENNA 5.(1) 1/2"Ø COAX FOR EACH TTA 6.(2) 3/8"Ø COAX FOR EACH MICROWAVE ANTENNA SITE NOTES CONSTRUCTION PLAN KEYED NOTES 15 WATER TANK 34'-0" 11 12 16 13 31 12 TO BALD HILLSTO CR A W F O R D 4 32 31 31 31 31 Y E L M ELEVATION A-3.01PROPOSED SOUTH ELEVATION (LOOKING NORTH) ·ALL CONSTRUCTION SHALL BE DONE IN ACCORDANCE WITH MOTOROLA'S R-56 DESIGN STANDARDS NOTE: Network Services, LLC SOLUTIONSMOTOROLA SHEET NUMBER SUBMITTALS DATE: DRAWN BY: CHECKED BY: SITE DESCRIPTION BYDATE SHEET TITLE REV YELM WATER TANK 901 RHOTON RD NW YELM, WA 98597 5-28-20 ENS RBH 1 5-28-20 PRELIMINARY ZONING ENS 2 6-11-20 RPZD: ADD SURVEY AAL 3 6-17-20 LEASE EXHIBIT ENS 4 6-23-20 REVISED LEASE EXHIBIT AAL 5 7-18-20 PRELIMINARY ZONING MAZ 6 9-01-20 FINAL ZONING DRAWINGS PPK APPROVAL STAMP www.LDCcorp.com 20210 142nd Avenue NE Woodinville, WA 98072 F 425.482.2893T 425.806.1869 Sur vey ing Engineer ing Pla nn ing Woodinville 1851 Central Pl S, #101 Kent, WA 98030 KentTCOMM9- 1-1POLICE ·FIRE ·MEDICAL 9 · 1 · 1 RICHARD B. HALL STATE OF WASHINGTON 8828 REGISTERED ARCHITECT PROPOSED TCOMM911 10'-0" TALL PEDESTAL MOUNTED ICE BRIDGE W/ 8'-0" CLEAR BELOW COAX SUPPORT. PROPOSED TCOMM911 OMNI ANTENNA, TYP (2 TOTAL). PROPOSED TCOMM911 TTA UNIT (1 TOTAL). PROPOSED TCOMM911 MICROWAVE WITH MOUNT (2 TOTAL). PROPOSED TCOMM911 90"x33"x47" 35Kw GAS (LIQUID PROPANE FUELED) KOHLER STANDBY GENERATOR ANCHORED TO 5'x10' CONCRETE PAD. PROPOSED TCOMM911 1000 GAL LP TANK ANCHORED TO RAISED CONCRETE SLAB ABOVE FLOOD PLANE.. STRUCTURAL PENDING. PROPOSED TCOMM911 (5'x5') 3-STEP CONCRETE STOOP WITH ACCESS RAISED ABOVE FLOOD PLANE (1 TOTAL). PROPOSED TCOMM911 EQUIPMENT SHELTER ANCHORED TO RAISED CONCRETE SLAB ABOVE FLOOD PLANE. STRUCTURAL PENDING. EXISTING 152.8' WATER TANK. PROPOSED TCOMM911 LEASE AREA. SEE SITE NOTES FOR PROPOSED COAX SIZE AND QUANTITY PROPOSED TCOMM911 ARBORVITAE SCREEN (9 TOTAL, ACTUAL LOCATION TBD). 1 3 4 5 11 12 13 15 22 23 31 32 1.VERIFY ANTENNA MODEL, TIP HEIGHT & AZIMUTHS. 2.ANALYSIS OF TOWER & FOUNDATION SHALL BE PERFORMED BY LDC & STAMPED BY A LICENSED STRUCTURAL ENGINEER. 3.(1) 7/8"Ø COAX FEEDERS FOR EACH 700MHz Rx ANTENNA 4.(1) 7/8"Ø COAX FEEDERS FOR EACH 700MHz Tx ANTENNA 5.(1) 1/2"Ø COAX FOR EACH TTA 6.(2) 3/8"Ø COAX FOR EACH MICROWAVE ANTENNA SITE NOTES CONSTRUCTION PLAN KEYED NOTES TOP OF PROPOSED WATER TANK 152.8' AGL RAD CENTER OF PROPOSED TCOMM911 MICROWAVE (MW 1,MW 2) 138.0' AGL BASE HEIGHT OF PROPOSED TCOMM911 ANTENNAS (Tx1, Rx1) 163.0' AGL FINISH GRADE 0.0' AGL 4 12 11 3 22 5 PROPOSED TCOMM911 10'-0" LEASE AREA PROPOSED TCOMM911 12'-0" EQUIPMENT SHELTER 3 1 (BEYOND) 23 32 ABOVE GRADE 2.0' AGL 15 LEG 6 LEG 1 (BEYOND) LEG 5 LEG 3 LEG 2 (BEYOND) LEG 4 22"x34" SCALE: 3/32" = 1'-0"11"x17" SCALE: 3/64" = 1'-0" 31 16 31 13 31 31 31