Loading...
2020.0022 211 Jefferson Duplex Structural CalcsSTRUCTURAL CALCULATIONS For Cynthia Schmier Duplex Lateral and Vertical Design October 1, 2020 Project # 2020237 By PRECISE ENGINEERING INC. HAROLD HAHNENKRATT, P.E. SCOPE: Provide structural calculations for lateral and vertical design per the 2015 IBC. Duplex to be built once at 211 Jefferson Ave NE in Yelm WA 98597 LOADS AND MATERIALS Roof: Comp Roofing S.Opsf Pre-engineered Trusses @ 24" oc 2.9psf Roof Sheathing 1.5psf Insulation 1.2psf 5/8" GWB 2.8psf Misc. 1.5psf Dead Load = 14.9» 15psf Snow Load = 25psf Wall: Siding (Lap) 3.Opsf Sheathing 1.5psf 2x6 Studs @ 16"oc 1.7psf Insulation 0.75psf %" GWB 2.2psf Misc 1.5psf Dead Load = 10.65>12psf Floor: I joists at 16"oc Dead Load = 12psf Part. Load = 1Opsf Live Load = 40psf Deck: Dead Load = 12psf Live Load = 60psf Wind: 110 MPH Exp. B Seismic: Site Class = D Design Category = D Use Group = I R = 6.5 Cd = 4 wo = 3 Soil: = 1500 PSF, Assumed bearing capacity = 38 PCF, Assumed Active Fluid Pressure = 350 PCF, Assumed Passive fluid Pressure = 0.45, Assumed Coefficient of Friction = 110 PCF, Assumed Soil Density Lumber: 2x > 4x = #2DF 6x > _ #1DF GLB = 24f -v4 for simple span = 24f -v8 for cont. and cantilever. Concrete: f e = 2500psi Rebar = Grade 60 U.S. Seismic Design Maps Page 1 of 3 �NEFQr Osili P 4� aQ e - u CAIx'UNNIA - 210 Jefferson Ave NE, Yelm, WA 98597, USA Latitude, Longitude: 46.9416929, -122.60368289999999 https://seismicmaps.org/ 5/31/2019 ...__.. _h._ 507 ✓���" Google ---- Map data 02019 Date 5/31/2019, 12:56:03 PM Design Code Reference Document ASCE7-10 Risk Category II Site Class D - Stiff Soil Type ass � Value Description 1.248 MCER MCER ground motion. (for 0.2 second period) S1 0.497 MCER ground motion. (for 1.0s period) SMs 1.249 Site -modified spectral acceleration value SMi 0.747 Site -modified spectral acceleration value Scs 0.833 Numeric seismic design value at 0.2 second SA Sol 0.498 Numeric seismic design value at 1.0 second SA Type Value Description SDC D Seismic design category Fa 1.001 Site amplification factor at 0.2 second F„ 1.503 Site amplification factor at 1.0 second PGA 0.5 MCEG peak ground acceleration FPGA 1 Site amplification factor at PGA PGAM 0.5 Site modified peak ground acceleration TL 16 Long -period transition period in seconds SsRT 1.248 Probabilistic risk -targeted ground motion. (0.2 second) SsUH 1.266 Factored uniform -hazard (2% probability of exceedance in 50 years) spectral acceleration SsD 1.5 Factored deterministic acceleration value. (0.2 second) S1 RT 0.497 Probabilistic risk -targeted ground motion. (1.0 second) S1 UH 0.528 Factored uniform -hazard (2% probability of exceedance in 50 years) spectral acceleration. SID 0.6 Factored deterministic acceleration value. (1.0 second) PGAd 0.5 Factored deterministic acceleration value. (Peak Ground Acceleration) CRs 0.986 Mapped value of the risk coefficient at short periods https://seismicmaps.org/ 5/31/2019 ps30 Pitch Roof Wall 2:12 -7.2 17.76 3:12 -6.5 19.65 4:12 -5.7 21.5 5:12 -0.5 21.4 6:12 6.87 20.3 >7:12 13.3 19.4 LATERAL DESIGN Wind Loading: Ps =AKztPs30 ASD P. = .6 AKZtps30 Wind Speed Exposure Roof Pitch A= 1 KZt = 1 Simplified (ASCE 7-10 Chapter 28 Part 2) 110 mph B 5:12 ps30 = -0.5 (Roof) 21.4 (Wall) ASD Ps= 0.3 (Roof) 12.8 (Wall) Seismic Loading: SDS 0.833 Ps = Ps' Section 12.4,12.8 ASCE7-10 E,=rQt, Qh=V V= CSW CS SDS/1.4R E=(1.3SDS/1.4R)W Minimum Loading 8.0 (Roof) 16.0 (Wall) (ASD) Minimum Loading r4.8'> (Roof) 9.6 (Wall) R = 6.5 (Wood Shear Wall) R = 1.5 (Cantilever Column) V= 0.119 Wt. (Wood Shear Wall) V= 0.516 Wt. (Cantilever Column) r=1.3 �DR �:OMPL I ANCE WIT: 15 CREDITS REQUIRED) NT HVAC 3a (IID) ,TER HEATING 5a (05) OVIDED FIRST KO®R PI AN Two Story Wind to Diaphragm Wind Upper Plate Height 8.1 Roof 4.8 Main Plate Height 8.1 Walls 12.8 Floor Depth 1 Diaphragm Roof Ht. Wind Load Length Total Load 1-2 Roof 4.5 0.0 73.4 30.0 2203.2 Upper 116.5 30.0 3494.4 SUM 5697.6 Roof Ht. Wind Load Length Total Load A -B Roof 5.3 0.0 77.3 39.5 3052.6 Upper 0 116.5 39.5 4601.0 B -C Roof 2.7 0.0 64.8 6.8 437.4 Upper 0 116.5 6.8 786.2 C -D Roof 5.3 0.0 77.3 20.8 1603.6 Upper.- -1-1-6-5-20L. 82� SUM 128977 �v e� j ` 1� N dO N T C M LO rn c a Q c� w O Co N O 0 U c r a� IC) al -al E -al d LO O c0 LO O O C) C.7 N r N T IC6 N O O 0 0 co N O U d U C15 (6 C6 cl� U •N w °o C � U) U) O O O O Z 0) O T T N .-. LO (� Cn lO co O U ti Lf 'p O I— T CM co LO ti r N M r C: 4- O T co (n LO m I LO LO O IQ L� co LO I M N M N co co COO U C U T T O E O c N . �_ C14 U Q CO OT cA d N ON U) F- U O O O O Q L() CO I` co RS D S U N N � =0 0 O CO T ILO t N N a L6 Q Q 4- 4- O r co O. 0- It LO 00 O U T > .-. N T I` O � O O N-0 O O co C) 00 CIO) O LO O LO U M .0 a— U r E r N N N �_ .L i N � .-. Ln O O U) 00 00 O M C 4- 0) I� O O Cfl U O co Cfl co co O O co J m cn co It O O Ln LO O M c0 O O co T O M O O M co co co N a_- v a a .. O T co LO 00 LO co 4- w 5 `'' O _ O N M O M N r r U J N 4- U O 4- N 4- o o 'D U) o Q o f o O T N � N N [D U � J r Q CO co U c a� E IC6 O O 0 0 co O d d C15 Ch C6 cl� C Z .-. LO (� lO O O ti I— N CM LO ti N M r C: O O T co (n LO m LO T LO I Icq T N N LOO r- N N co co COO C O T d O O O co 0 C14 Q CO OT o d N ON F- m D S N � ILO t N N C" Q CO N O r co co It LO U > .-. O LO I` O � N O N-0 O O co C) 00 CIO) O LO O LO M .0 a— U r M r N N M 00 i � .-. Ln O O O 00 00 O C 4- 0) I� O O Cfl O O co Cfl co co T T co J O O Ln LO M M c0 O O O O M O O M co co co N .. O T co LO 00 LO co 4- w 5 `'' O _ O ti O T N r r J N 4- N O 4- N 4- o o Q o Q o f � N [D U � J r Q CO U U) W Z J O H 0 Q O J D O O L O � O� O O� O O ODO0 O I— t d' O M 'T �— (B O 0 0 0 0 0 0 0 0 0 LC) 0 N 0 0 C:, N 0 0 co m CO N N co CO U) 7 U) 7 N > N J O 00 O co 0) co mmm � co O O O co O co M CO N N O O O O O Ce) O O 0 OLO r- O CO O O 0 0 0 0 N O s— co N N co E E Z U) [n O 4 Mm W O N N O LO O co LO NCO LO N LO C N Q m U J TYPICAL SHEAR WALL NOTES Use 5/8" dia. by 10" Anchor Bolts (AB's) with single plates and 5/8" dia. by 12" AB's with double and 3x plates spaced as shown on the drawings. AB's shall have 7" of embedment into footing, shall be centered in the stud wall, and shall project through the bottom plate of the wall and have a 3x3x1/4 plate washer. There shall be a minimum of two bolts per piece of sill located not more than 12 inches or less than 4 inches end of each piece. Anchor bolts to be galvanized per the below requirement (Fasteners in contact with pressure treated lumber). At existing foundation use 5/8" diameter Simpson Titen HG bolts with minimum of 4" embedment into the existing concrete. All wall sheathing shall be 1/2" CDX plywood, 5/8" T1-11 siding, or 7/16" OSB with exterior exposure glue and span rated "SR 24/0" or better. All free sheathing edges shall be blocked with 2x4 or 2x6 flat blocking except where noted on the drawings or below. All nails shall be 8d or l Od conunon (8d common nails must be 0.131 inch diameter, Senco KC27 Nails are equivalent. If l Od common nails are called for the diameter must be 0.148 inches, Senco MD23 Nails are equivalent). Nail size and spacing at all sheathing edges shall be as required below or as in the drawings. Nail spacings shall be 12" o.c. for all field nailing except as noted. Hold downs are Simpson "Strong Tie" and shall be installed per the manufacture's recommendation. Equivalent hold downs by United Steel Products Company "Kant -Sag" that have ICBG approval can be substituted in place of Simpson hold downs. All floor systems must be blocked solid below member that the hold down is attached to. This block should be equal to or larger than the member the hold down is attached to and be placed as a "squash block". All double and triple studs shall glued and nailed together with 10d's at 3" o.c. for each layer. All 4x studs are to be #2 DF and all 6x studs are to be #1 DF when used for hold downs and shear walls. FASTENERS IN CONTACT WITH PRESSURE TREATED LUMBER All fasteners including nuts and washers in contract with pressure treated lumber shall be hot -dipped zinc coated galvanized steel, stainless steel, silicon bronze or copper. Fasteners other than nails, timber rivets, wood screws and lag screws shall be permitted to be of mechanically deposited zinc coated steel in accordance with ASTM B 695, Class 55 minimum. Fasteners exposed to weather must meet the requirements of the pressure treating manufacture's minimum. IN ADDITON, the contractor shall coordinate connector/fastener coating requirements with recommendations from connector/fastener manufacturer and type of pressure treating chemical and retention being used. See Section 2304.10.5 of the 2015 IBC for additional information. ALL WALL STUDS AND ROOF TRUSS TOP CHORDS AND SECONDARY FRAMING LUMBER SHALL BE DOUG -FIR #2 OR BETTER. NOTE: MST STRAPS attaches to (2) 2x or 4x studs in wall above and below unless noted otherwise. Nail all holes with 16d sinkers. Double studs may be use as a substitute for 3x nominal framing call out below. Studs MUST be glued and nailed together with (2) lines of 10d's at 3" on center staggered. Horizontal blocking for shear walls nailed with 8d's shall be minimum of 2x flat and shear walls nailed with IOd's shall be minimum of 3x flat. SHEAR WALL SCHEDULE ZNsheathing nailed with 8d's at 6" on center all edges. HOLD DOWN SCHEDULE It is the responsibility of the contractor to locate hold down anchor bolt to accommodate all structural framing. Anchor bolt to be located nearest the corner or opening at the end of the shear wall. All foundation vents to be a minimum of 12" off centerline of the anchor bolt on either side. Holdown stud to be coordinated with shear wall panel edge framing requirements. Larger stud size controls * For holdown anchor bolt embedment greater that foundation depth, thicken footing for 2'-0" either side of holdown anchor bolt to a depth that provides for 3" clear below the bottom of the anchor bolt. Provide (2) additional #4 x 3'-0" pieces of longitudinal rebar at this location. qD HD U2 attaches to concrete foundation with a Simpson SSTB 16. HD U2 attaches to double 2x studs or 4x or 6x stud with (6) Simpson SDS 1/4 X 3 Wood Screws in wall above. FLOOR TO FLOOR STRAP META 49 Simpson META 49 is a floor to floor strap that is centered on the rim joist. The strap attaches to a minimum of a single stud in the wall above and below. Shear wall boundary member and Holdown member requirements will usually control member size. Install per Simpson's requirements. r • STRUCTURAL NOTE'S General Notes: These structural notes supplement the drawings. Any discrepancy found among the drawings, these notes, and the site conditions shall be reported to the Engineer, who shall correct such discrepancy in writing. Any work done by the Contractor after discovery of such discrepancy shall be done at the Contractor's risk. The Contractor shall verify and coordinate the dimensions among all drawings prior to proceeding with any work or fabrication. The Contractor shall coordinate between the architectural drawings and the structural drawings. The architectural dimensions are taken to be correct when in conflict with the structural drawings. The Contractor is responsible for all bracing and shoring during construction. All construction shall conform to the applicable portions of the latest edition of the International Building Code except where noted Design Criteria: 1. Live Load = 40 PSF (Floors) = 25 PSF (Snow) 2. Dead Load = 15 PSF (Roof) = 12 PSF (Floor) = 10 PSF (Walls) = 150 PCF (Concrete) 3. Partition = 10 PSF (Floors) 4. Wind = 2015 IBC Exposure B @ 110 mph 5. Earthquake = 2015 IBC Site Class = D Design Cat. = D Use Group = I R = 6.5 Cd = 4 Wo = 3 6. Soil = 1500 PSF, Assumed bearing capacity = 38 PCF, Assumed Active Fluid Pressure = 350 PCF, Assumed Passive fluid Pressure = 0.45, Assumed Coefficient of Friction = 110 PCF, Assumed Soil Density Concrete & Reinforcing Steel: All concrete work shall be per the 2015 IBC Chapter 19. 2. All reinforcing shall be ASTM A615 Grade 60 except as shown on the plans. 3. Concrete shall be in accordance with ASTM 150. fc = 2500 PSI @ 28 day slump = 4" maximum, 6% Air entrained. 4. Garage slab and exterior slabs to have minimum thickness of 4" with 6x6 W1.4x1.4 WWF with vapor barrier. This is at the owner's option to reduce slab cracking. Crack control joints the responsibility of the contractor Steel: 1. Anchor bolts shall be ASTM A307. Carpentry: 1. 2X structural framing shall be #2 Douglas Fir. 4x structural members shall be #2 Douglas Fir. 6X members shall be #1 Douglas Fir. 2. Provide solid blocking in floor system below all bearing walls and point loads. 3. 2X joists shall be kiln dried and stored in a dry area prior to installation. The moisture content of all wood shall be less than 15%. 4. Floor joists shall be by Boise Cascade or other approved manufacturer. Joist to be installed and braced per manufacturer's requirements. 5. Roof trusses shall be by a pre -approved manufacturer and constructed according to the specifications of the Truss Plate Institute. Truss shop drawings must be stamped by a licensed engineer and be on site at the time of construction. Preliminary truss drawings must be reviewed prior to construction. It is the truss manufacturer's responsibility to inform the engineer of record of any changes from the preliminary truss lay -out. Girder trusses to have a minimum of bearing studs equal to number of plies of truss. All girder trusses shall have Simpson HGT tie down at either end to match number of plies. Truss manufactures are responsible for all bracing of the trusses including end wall bracing and all other bracing between the building and the trusses unless specifically shown otherwise on the drawings. Contractor to coordinate bracing with engineer of record as required. 6. Glue laminated beams shall be 24F -V8 for cantilevered or continuous beams and 24F -V4 for simple spans. (Fb = 2,400 PSI) (Fv = 190 PSI) (E = 1,800,000 PSI) (FcL = 650 PSI) 7. Continuous and cantilevered glue laminated beams shall not be cambered. All other glue laminated beams shall be cantilevered for L/480. See the framing plans for any exceptions. 8. All manufactured lumber shall be by Boise Cascade and have the following structural properties: Versa Lam (VL) (Fb = 2,800 PSI) (Fv = 280 PSI) (E = 2,000,000 PSI) (FcL = 750 PSI) 9. Sheathing at roof and floor shall be laid with face grain perpendicular to supports and end joints staggered 4'-0" on center. Provide 1/8" space at panel edges as required by panel manufacturers. Floor sheathing shall be nailed 6" o.c. edges and 12" field with 10d's and roof sheathing shall be nailed 6" o.c. edges and 12" o.c field with 10d's unless otherwise noted on the drawings. 10. Block and nail all horizontal panel edges at designated shear walls. 11. All beams to be supported by a minimum of a solid post that matches the width of the wall and the width of the beam unless noted otherwise. A 6x beam bearing in 2x6 wall will be a 6x6. Provide solid squash blocking to match in floor system and match post size in foundation. Contact Engineer of record for any deviations. 12. All fasteners in contact with pressure treated lumber will meet the below requirements. All fasteners including nuts and washers in contract with pressure treated lumber shall be hot -dipped zinc coated galvanized steel, stainless steel, silicon bronze or copper. Fasteners other than nails, timber rivets, wood screws and lag screws shall be permitted to be of mechanically deposited zinc coated steel in accordance with ASTM B 695, Class 55 minimum. Fasteners exposed to weather must meet the requirements of the pressure treating manufacture's minimum. IN ADDITON, the contractor shall coordinate connector/fastener coating requirements with recommendations from connector/fastener manufacturer and type of pressure treating chemical and retention being used. See Section 2304.10.5 of the 2015 IBC for additional information. 13. All GWB to be installed per the IBC and Gypsum Association's publication for the Application and Finishing of Gypsum Board, GA -216 Hardware: All connection hardware shall be Simpson "Strong Tie". Connection hardware exposed to the weather or soil shall be treated as in steel above. '.31j�Le PLACE TRUSSES PER MANUFACTURER'S RECOMMENDATIONS AND BRACE PER TRUSS COMPANY RECCOMENDATIONS. CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY BRACING AND SHORING REQUIRED FOR PLACING TRUSSES. NOTE THESE DRAWINGS DO NOT INCLUDE ANY TEMPORARY SHORING OR BRACING. PRECISE ENGINEERING RECCOMENDS ALL SHORING AND BRACING BE DESIGNED AND DETAILED BY A LISENCED ENGINEER. CONTRACTOR TO FIELD VERIFY ALL CONDITIONS AND ALL ELEVATIONS Uw 4= w w- @ co 0 0 NOI (0 OO m qO. U N co V (D M U (o d' Cl) N (0 N N (0 (O @ f0 (p W co W O O m U) U N O W U U m (O Ln O O h CO d' I� cl O (O O W (U U N V' (O O o N 00 � 0 T U O S S S 2 S 7 O Q O7 U cn m o ma m:?m m L � o U UCL a Q � wU->('i U) LO V O3 co co OD m CL m U O V M N CO N (0 (O M W U 'O -0 U 'D O O Cb OD (`a m O O U r ROOF FRAMING NOTES 1. USE 112' CDX OR 1/16" OSB SPAN RATED 24/0 OR BETTER AND NAIL U)/ Sd NAILS a 6" O.C. EDGES AND s 12' O.C. M THE FIELD. (UNLESS NOTED OTHERWISE) 2. ALL HEADERS TO BE 6.8 OF -2 OR 410 LKLE66 NOTED OTHERIISE R®0r- FRAMING PLAN �/�' 3. TOP PLATE SPLICES: NAIL SPLICES w/ — ROM 10d NAILS s 2" OO. FOR 24" SCALE: 1/4' . P-0' EITHER SIDE OF SPLICE (24) MR 10d NAILS EACH SIDE OF SPLICE. 4. ALL ROOF OVER FRAMING COORDINATE w/ GENERAL. CONTRACTOR Title Block Line 1 Project Title: You can change this area Engineer: using the "Settings" menu item Project ID: and then using the "Printing & Project Descr: Title Block" selection. 1600 ksi Density Title Block Line 6 Printed: 7 JUN 2019, 11:11 AM Multiple Simple �e1nl File= C:\Users\Harold\DOCUME-1\ENERCA-1\Schmierduples.ec6 , p p, Software copyright ENERCALC, INC. 1983-2019, Build:10.18.12.31 . Description Nood Beam Design: A Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 BEAM Size: 6x8, Sawn, Fully Unbraced Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending Wood Species: Douglas Fir - Larch Wood Grade: No.2 Fb - Tension 875 psi Fc - Prll 600 psi Fv 170 psi Ebend- xx 1300 ksi Density 31.21 pcf Fb - Compr 875 psi Fc - Perp 625 psi Ft 425 psi Eminbend - xx 470 ksi Applied Loads Unif Load: D = 0.0150, S = 0.0250 k/ft, Trib= 6.250 ft Design Summary - Max fb/Fb Ratio = 0.764: 1 fb : Actual : 764.09 psi at 5.125 ft in Span # 1 Fb : Allowable: 1,000.72 psi Load Comb: +D+S+H Max fv/FvRatio = 0 210: 1 ... • in 11, MR • .250 ft fv : Actual : 41.00 psi at 0.000 ft in Span # 1 Fv: Allowable: 195.50 psi Load Comb: +D+S+H Max Deflections Max Reactions (k) D L Lr S W E H Transient Downward 0.155 in Total Downward 0.248 in Left Support 0.48 0.80 Ratio 792 >240 Ratio 495 >240 Right Support 0.48 0.80 LC: S Only LC: +D+S+H Transient Upward 0.000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 LC: LC: Wood Beam Design: B Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 BEAM Size: 4x6, Sawn, Fully Unbraced Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending Wood Species: Douglas Fir - Larch Wood Grade: No.2 Fb - Tension 900 psi Fc - Prll 1350 psi Fv 180 psi Ebend- xx 1600 ksi Density 31.21 pcf Fb - Compr 900 psi Fc - Perp 625 psi Ft 575 psi Eminbend - xx 580 ksi Applied Loads Unif Load: D = 0.0150, S = 0.0250 k/ft, Trib= 5.50 ft Design Summary ..............(o o8aso)S(o 1375).- 75)..Max Maxfb/Fb Ratio = 0.126. 1 fb : Actual : 168.31 psi at 1.500 ft in Span # 1 Fb: Allowable: 1,340.90 psi Load Comb: +D+S+H Max fv/FvRatio = 0.087: 1 fv : Actual : 18.00 psi at 2.550 ft in Span # 1 3. 0 ft Fv : Allowable: 207.00 psi Load Comb: +D+S+H Max Deflections Max Reactions (k) D L Lr S W E H Transient Downward 0.003 in Total Downward 0.005 in Left Support 0.12 0.21 Ratio 9999>240 Ratio 6934 >240 Right Support 0.12 0.21 LC: S Only LC: +D+S+H Transient Upward 0.000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 LC: LC: Title Block Line 1 You can change this area using the "Settings" menu item and then using the "Printing & Title Block" selection. Title Block Line 6 Multiple Beam Wood Beam Design: C Project Title: Engineer: Project ID: Project Descr: File = C:1Useri Software cop Printed: 7 JUN 2019, 11:11AM Id1DOCUME-1IENERCA-11Schmier duples.ec6 ENERCALC, INC. 1983-2019, Build:10.18.12.31 Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 BEAM Size: 4x6, Sawn, Fully Unbraced Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending Wood Species: Douglas Fir - Larch Wood Grade: No.2 Fb - Tension 900 psi Fc - Prll 1350 psi Fv 180 psi Ebend- xx 1600 ksi Density 31.21 pcf Fb - Compr 900 psi Fc - Perp 625 psi Ft 575 psi Eminbend - xx 580 ksi Applied Loads Unif Load: D = 0.0150, S = 0.0250 k/ft, Trib= 4.0 ft Design Summary Max fb/Fb Ratio = 0.464; 1 1, .._o(o 060).S -.(Q. -.-1o)....__. fb : Actual : 619.69 psi at 3.375 ft in Span # 1 ter. . _- Fb: Allowable: 1,335.66 psi Load Comb: +D+S+H 4x6 Max fv/FvRatio = 0.176: 1 6.750 ft fv : Actual : 36.47 psi at 6.300 ft in Span # 1 Fv: Allowable: 207.00 psi Load Comb: +D+S+H Max Deflections Max Reactions (k) g L Lr S W E H Transient Downward 0.060 In Total Downward 0.097 in Left Support 0.20 0.34 Ratio 1339>240 Ratio 837 >240 Right Support 0.20 0.34 LC: S Only LC: +D+S+H Transient Upward 0.000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 LC: LC: _ Wood Beam Design: ' p _ Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7.10 BEAM Size: 4x6, Sawn, Fully Unbraced Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending Wood Species : Douglas Fir - Larch Wood Grade: No.2 Fb - Tension 900 psi Fc - Prll 1350 psi Fv 180 psi Ebend- xx 1600 ksi Density 31.21 pcf Fb - Compr 900 psi Fc - Perp 625 psi Ft 575 psi Eminbend - xx 580 ksi Applied Loads Unif Load: D = 0.0150, S = 0.0250 k/ft, Trib= 10,250 ft Design Summary D(o 1538)_s(0 2563)__ ----- ------ Max fo/Fb Ratio = 0.319 : 1 fb : Actual : 426.94 psi at 1.750 ft in Span # 1 p Fb : Allowable: 1,340.20 psi Load Comb : +D+S+H _ Max fv/FvRatio = 0,200:1 4x6 fv : Actual : 41.37 psi at 3.045 ft in Span # 1 3.50 ft Fv: Allowable: 207.00 psi ' Load Comb: +D+S+H Max Deflections Max Reactions (k) D L Lr S w E H Transient Downward 0.011 in Total Downward 0.018 in Left Support 0.27 0.45 Ratio 3748>240 Ratio 2343 >240 Right Support 0.27 0.45 LC: S Only LC: +D+S+H Transient Upward 0.000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 LC: LC: Title Block Line 1 Project Title: You can change this area Engineer: using the "Settings" menu item Project ID: and then using the "Printing & Project Descr: Title Block" selection. Max fv/FvRatio = Title Block Line 6 Printed: 7 JUN 2019, 11:11 AM Multiple Simple p p File=C:\Users\Harold\DOCUME-1\ENERCA-1\Schmierduples.ec6 Software copyright ENERCALC,'INC.1983-2019, Build:10.18.12.31 . Wood Beam Design E Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 BEAM Size: 4x6, Sawn, Fully Unbraced Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending Wood Species : Douglas Fir - Larch Wood Grade: No.2 Fb - Tension 900.0 psi Fc - Prll 1,350.0 psi Fv 180.0 psi Ebend- xx 1,600.0 ksi Density 31.210 pcf Fb - Compr 900.0 psi Fc - Perp 625.0 psi Ft 575.0 psi Eminbend - xx 580.0 ksi Applied Loads Unif Load: D = 0.0150, S = 0.0250 k/ft, Trib=17.0 ft Design Summary Max fb/Fb Ratio = 0.690: 1 fb : Actual : 924.86 psi at 2.000 ft in Span # 1 Fb : Allowable: 1,339.53 psi Load Comb: +D+S+H 0.000 ft in Span # 1 Max fv/FvRatio = 0.396: 1 fv : Actual : 81.95 psi at 0.000 ft in Span # 1 Fv: Allowable: 207.00 psi S W E Load Comb: +D+S+H 0.31 Max Reactions (k) D L Lr S W E Left Support 0.51 0.85 Right Support 0.51 0.85 LC: S Only LC: +D+S+H Transient Upward 0.000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 LC: LC: Wood Beam Design: F Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 BEAM Size: 4x6, Sawn, Fully Unbraced Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending Wood Species : Douglas Fir - Larch Wood Grade: No.2 Fb - Tension 900 psi Fc - Prll 1350 psi Fv 180 psi Ebend- xx 1600 ksi Density 31.21 pcf Fb - Compr 900 psi Fc - Perp 625 psi Ft 575 psi Eminbend - xx 580 ksi Applied Loads Unif Load: D = 0.0150, S = 0.0250 k/ft, Trib= 6,250 ft Design Summary Max fb/Fb Ratio = 0.254: 1 fb : Actual : 340.02 psi at 2.000 ft in Span # 1 Fb • Allowable 1 339 53 psi Load Comb: +D+S+H Max fv/FvRatio = 0.146: 1 fv : Actual : 30.13 psi at 0.000 ft in Span # 1 Fv: Allowable: 207.00 psi Load Comb: +D+S+H Max Reactions (k) D L Lr S W E Left Support 0.19 0.31 Right Support 0.19 0.31 i Max Deflections H Transient Downward 0.012 in Total Downward 0.019 in Ratio 4118 >240 Ratio 2574 >240 LC: S Only LC: +D+S+H Transient Upward 0.000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 LC: LC: Title Block Line 1 You can change this area using the "Settings" menu item and then using the 'Printing & Title Block" selection. Title Block Line 6 Multiple Simple Beam Wood Beam Design: G Project Title: Engineer: Project ID: Project Descr: File = C:1L Software Printed: 7 JUN 2019. 11:11 ANI INC. 1983-2019, Build:10.18.12.31 . Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 3EAM Size: 6x8, Sawn, Fully Unbraced Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending Wood Species : Douglas Fir - Larch Wood Grade: NoA Fb - Tension 1350 psi Fc - Prll 925 psi Fv 170 psi Ebend- xx 1600 ksi Density 31.21 pcf Fb - Compr 1350 psi Fc - Perp 625 psi Ft 675 psi Eminbend - xx 580 ksi Applied Loads Unif Load: D = 0.0150, S = 0.0250 k/ft, Trib=17.0 ft Point: D =1.270, S = 2.125 k @ 2.0 ft Design Summary Max fb/Fb Ratio = 0.7,15: 1 fb : Actual : 1,106.62 psi at 2.000 ft in Span # 1 Fb: Allowable: 1,548.04 psi Load Comb: +D+S+H Max fv/FvRatio = 0.49'1 : 1 fv : Actual : 96.02 psi at 0.000 ft in Span # 1 Fv : Allowable: 195.50 psi Load Comb: +D+S+H Max Reactions (k) D L Lr S W E Left Support 1.15 1.91 Right Support 1.15 1.91 LC: S Only LC: +D+S+H Transient Upward 0.000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 LC: LC: FLOOR FRAMING N I. USE 3/4" FLOOR SHEATHING GLUE W/ 10d NAILS n 6" O.G. AT EDGES • 101 O.C. IN THE FIELD. (URO) 2. BLOCK ALL UNSUPPORTED EDGES k FLOOR JOISTS. Title Block Line 1 Project Title: You can change this area Engineer: using the "Settings" menu item Project ID: and then using the "Printing & Project Descr: Title Block" selection. 3082 >360 Ratio Title Block Line 6 Printed: 7 JUN 2019, 11:28AM Multi !e Simple Beam File=C:\Users\Harold\DOCUME-I\ENERCA•-I\Schmierduples.ec6 . Software copyright ENERCALC, INC. 1983-2019, Build: 10.18.12.31 Description : Wood Beam Design: A Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 BEAM Size: 4x8, Sawn, Fully Unbraced Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending Wood Species : Douglas Fir - Larch Wood Grade: No.2 Fb - Tension 900.0 psi Fc - Prll 1,350.0 psi Fv 180.0 psi Ebend- xx 1,600.0 ksi Density 31.210 pcf Fb - Compr 900.0 psi Fc - Perp 625.0 psi Ft 575.0 psi Eminbend - xx 580.0 ksi Applied Loads Unif Load: D = 0.0150, S = 0.0250 k/ft, Trib=17.0 ft Unif Load: D = 0.0960 k/ft, TO= 1,0 ft Unif Load: D = 0.0220, L = 0.040 k/ft, Trib=1.330 ft Design Summary Max fb/Fb Ratio = 0 471 1 fb : Actual : 630.31 psi at 2.000 ft in Span # 1 Fb : Allowable: 1,337.03 psi 0.016 in Load Comb: +D+S+H Ratio 3082 >360 Ratio Max fv/FvRatio = 0.322: 1 LC: +D+S+H fv : Actual : 66.64 psi at 0.000 ft in Span # 1 0.000 in Fv: Allowable: 207.00 psi Ratio 9999 Load Comb: +D+S+H 31.40 psi at Max Reactions (k) D L Lr S W E H Left Support 0.76 0.11 0.85 Right Support 0.76 0.11 0.85 WON Eli, I x Deflections Unif Load: D = 0.0220, L = 0.040 k/ft, Trib=13.50 Transient Downward 0.016 in Total Downward 0.026 in Ratio 3082 >360 Ratio 1830 >360 LC: +L+S LC: +D+S+H Transient Upward 0.000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 LC: 31.40 psi at LC: Woad Beam Design:- B Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 BEAM Size: 1.75x11.875, VersaLam, Fully Braced Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending Wood Species: Boise Cascade Wood Grade: Versa Lam 2.0 2800 West Fb - Tension 2800 psi Fc - Prll 3000 psi Fv 285 psi Ebend- xx 2000 ksi Density 41.76 pcf Fb - Compr 2800 psi Fc - Perp 750 psi Ft 1950 psi Eminbend - xx530120482 ksi Applied Loads Unif Load: D = 0.0220, L = 0.040 k/ft, Trib=13.50 ft Design Summary Max fb/Fb Ratio = 0.098: 1 fb : Actual : 274.50 psi at 1.500 ft in Span # 1 Fb: Allowable: 2,800.00 psi Load Comb: +D+L+H Max fv/FvRatio = 0.110: 1 fv : Actual : 31.40 psi at 2.020 ft in Span # 1 Fv: Allowable: 285.00 psi Load Comb : +D+L+H Max Reactions (k) D L Lr S W E Left Support 0.45 0.81 Right Support 0.45 0.81 H . u Transient Downward 0.002 in Total Downward 0.003 in Ratio 9999 >360 Ratio 9999 >360 LC: L Only LC: +D+L+H Transient Upward 0.000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 LC: LC: Title Block Line 1 You can change this area using the "Settings" menu item and then using the "Printing & Title Block" selection. Title Block Line 6 Multiple, Simple Beam Project Title: Engineer: Project ID: Project Descr: Printed: 7 JUN 2019, 11:28AM File= C:\Users\Harold\DOCUME-I\ENERCA-I\Schmierduples.ec6 Software coovriaht ENERCALC. INC. 1983-2019, Build:10.18.12.31 Wood Beam Design: B Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 BEAM Size: 1.75x11.875, Versal-am, Fully Braced Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending Wood Species : Boise Cascade Wood Grade: Versa Lam 2.0 2800 West Fb - Tension 2,800.0 psi Fc - Prll 3,000.0 psi Fv 285.0 psi Ebend- xx 2,000.0 ksi Density 41.760 pcf Fb - Compr 2,800.0 psi Fc - Perp 750.0 psi Ft 1,950.0 psi Eminbend - xx 1,036.83 ksi fv : Actual : 26.75 psi at 2.020 ft in Span # 1 ! 3.0 .ft - 439.71 psi at Fv: Allowable: 285.00 psi 1,163.69 psi Ratio Load Comb : Load Comb: +D+L+H Max Deflections 0.258: 1 Transient Upward Max Reactions (k) D L Lr S W E H Transient Downward 0.002 in Total Downward 0.003 in Left Support 0.38 0.69 Ratio 9999>360 Ratio 9999 >360 Right Support 0.38 0.69 LC: L Only LC: +D+L+H 0.64 0.48 0.31 Transient Upward 0.000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 LC: - LC: Wood Beam Design: p _ Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 BEAM Size: 4x8, Sawn, Fully Unbraced Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending Wood Species : Douglas Fir - Larch Wood Grade: No.2 Fb - Tension 900.0 psi Fc - Prll 1,350.0 psi Fv 180.0 psi Ebend- xx 1,600.0 ksi Density 31.210 pcf Fb - Compr 900.0 psi Fc - Perp 625.0 psi Ft 575.0 psi Eminbend - xx 580.0 ksi Applied Loads Unif Load: D = 0.0150, S = 0.0250 k/ft, Trib= 6.250 ft Unif Load: D = 0.0960 k/ft, Trib=1.0 ft Unif Load: D = 0.0220, L = 0.040 k/ft, Trib= 6.0 ft Design Summary Max fb/Fb Ratio = 0.378: 1 fb : Actual : 439.71 psi at 2.000 ft in Span # 1 Fb : Allowable: 1,163.69 psi Ratio Load Comb : +D+L+H LC: +L+S Max fv/FvRatio = 0.258: 1 Transient Upward fv : Actual : 46.49 psi at 0.000 ft in Span # 1 Fv: Allowable: 180.00 psi Ratio Load Comb: +D+L+H LC: Max Reactions (k) D L Lr S W E H Left Support 0.64 0.48 0.31 Right Support 0.64 0.48 0.31 all-111 wiNg 4.0 It K Deflections Transient Downward 0.013 in Total Downward 0.020 in Ratio 3720 >360 Ratio 2381 >360 LC: +L+S C: +D+0.750L+0.750S+H Transient Upward 0.000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 LC: LC: Title Block Line 1 Project Title: You can change this area Engineer: using the "Settings" menu item Project ID: and then using the "Printing & Project Descr: Title Block" selection. Title Block Line 6 Printed: 7 JUN 2019, 11:28AM Multiple Simple B p Beam ll l C:\Users\Harold\DOCUME-1\ENERCA-1\Schmierduples.ec6 479.96 psi at Software copyright ENERCALC, INC. 1983-2019, Build:10.18.12.31 illiali -r Wood Beam Design: E Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 BEAM Size: 3.5x11.875, VersaLam, Fully Braced Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending Wood Species: Boise Cascade Wood Grade: Versa Lam 2.0 2800 West Fb - Tension 2,800.0 psi Fc - Prll 3,000.0 psi Fv 285.0 psi Ebend- xx 2,000.0 ksi Density 41.760 pcf Fb - Compr 2,800.0 psi Fc - Perp 750.0 psi Ft 1,950.0 psi Eminbend - xx 1,036.83 ksi Applied Loads Unif Load: D = 0.0220, L = 0,040 k/ft, Trib= 8,50 ft Unif Load: D = 0.0960 k/ft, Tl 1.0 ft Unif Load: D = 0.0150, S = 0.0250 k/ft, Trib= 6,250 ft Unif Load: D = 0.0150, S = 0.0250 k/ft, Trl 1.0 ft Desi n Summar Max fb/Fb Ratio = 0.171 fb : Actual : 479.96 psi at 3.000 ft in Span # 1 ! -r Fb: Allowable: 2,800.00 psi Load Comb : +D+L+H - Max fv/FvRatio = 0.187: 1 IA. 3.5x11.875 Al fv : Actual : 53.32 psi at 5.020 ft in Span # 1 i 6.0 a Fv : Allowable: 285.00 psi j Load Comb: +D+L+H Max Deflections Max Reactions (k) Q L Lr S W E H Transient Downward 0.016 in Total Downward 0.023 in Left Support 1.18 1.02 0.54 Ratio 4608 >360 Ratio 3069 >360 Right Support 1.18 1.02 0.54 LC: +L+S C: +D+0.750L+0.750S+H Transient Upward 0.000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 LC: LC: Boise Cascade Single 11-7/8" BCI® 5000-1.7 DF J01 (Joist) BC CALCO Member Report Dry 11 span I No cant. 116 OCS I Repetitive I Glued & nailed June 7, 2019 11:21:34 Build 7192 Job name: File name: Address: Description: City, State, Zip: Specifier: Customer: Designer: Harold Hahnenkratt Code reports: ESR -1336 Company: Precise Engineering Inc ♦ ♦ i ♦ ♦ ♦ i i T r ♦ y v! ♦! i • Z i ♦ e ♦ i • ♦ ♦ ♦ v v ♦ • 11 v 1 ! ! 1 ♦ r • • v • v i r ♦ ♦ v i v �♦ v • i • ♦ • ♦ o ♦ ♦ ♦ • I B1 16-06-00 62 Total Horizontal Product Length = 16-06-00 Reaction Summary (Down / Uplift) (lbs) Bearing Live Dead Snow Wind Roof Live B1, 2" 550/0 132/0 B2, 2" 550/0 132/0 Load Summary Live Dead Snow Wind Roof OCs Live Tag Description Load Type Ref. Start End Loc. 100% 90% 115% 160% 125% 1 Standard Load Unf. Area (Ib/ft2) L 00-00-00 16-06-00 Top 40 12 16 2 part Unf. Area (Ib/ft2) L 00-00-00 16-06-00 Top 10 16 Controls Summary Value % Allowable Duration Case Location Pos. Moment 2743 ft -lbs 87.1% 100% 1 08-03-00— End Reaction 682 lbs 63.8% 100% 1 00-00-00 End Shear 668 lbs 41.1% 100% 1 00-02-00 Total Load Deflection U456 (0.429") 79.0% n1a 1 08-03-00 Live Load Deflection L/565 (0.346") 84.9% n1a 2 08-03-00 Max Defl. 0.429" 42.9% n1a 1 08-03-00 Span / Depth 16.5 % Allow % Allow Bearing Supports Dim. (LxW) Value Support Member Material B1 Wall/Plate 2" x 2" 682 lbs 27.3% 63.8% Douglas Fir B2 Wall/Plate 2" x 2" 682 lbs 27.3% 63.8% Douglas Fir BC FloorValue@ Summary BC FloorValueO: r " Subfloor: 3/4" OSB, Glue + Nail Minimum Enhanced Premium Subfloor Rating: Premium Controlling Location: 08-03-00 Notes Design meets User specified (U360) Total load deflection criteria. Design meets User specified (U480) Live load deflection criteria. Design meets arbitrary (1") Maximum Total load deflection criteria. Calculations assume member is fully braced. BC CALCO analysis is based on IBC 2015. Composite EI value based on 3/4" thick OSB sheathing glued and nailed to member Design based on Dry Service Condition. Page 1 of 1 Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALC@, BC FRAMERO , AJSTM, ALLJOIST@ , BC RIM BOARD-, BCI@ , BOISE GLULAMM, BC FloorValue@ , VERSA-LAMO, VERSA -RIM PLUS@ , )TWER E MMI &IMAtlnki 01 AM Boise cascade Eff99 Single 9-112" BCI® 5000-1.7 DF J02 (Joist) BC CALCO Member Report Dry 11 span I No cant. 116 OCS I Repetitive I Glued & nailed June 7, 2019 11:22:31 Build 7192 Job name: File name: Address: Description: City, State, Zip: Specifier: Customer: Designer: Harold Hahnenkratt Code reports: ESR -1336 Company: Precise Engineering Inc 12-00-00 B2 131 Total Horizontal Product Length = 12-00-00 Reaction Summary (Down / Uplift) (lbs) Bearing Live Dead Snow Wind Roof Live B 1, 4-1/4" 40010 96/0 B2, 4-1/4" 400/0 96/0 Summary Live Dead Snow Wind Roof ocs Load Live Tag Description Load Type Ref. Start End Loc. 100% 90% 115% 160% 125% 1 Standard Load Unf. Area (Ib/ft2) L 00-00-00 12-00-00 Top . 40 12 16 2 part Unf. Area (Ib/ft2) L 00-00-00 12-00-00 Top 10 16 Controls Summary Value %Allowable Duration Case Location Pos. Moment 1347 ft -lbs 54.7% 100% 1 06-00-00 End Reaction 496 lbs 44.1% 100% 1 00-00-00 End Shear 467 lbs 31.6% 100% 1 00-04-04 Total Load Deflection L/774 (0.177') 46.5% n1a 1 06-00-00 Live Load Deflection U960 (0.143") 50.0% n1a 2 06-00-00 Max Defl. 0.177' 17.7% n1a 1 06-00-00 Span / Depth 14.4 % Allow % Allow Bearing Supports Dim (LxW) Value Support Member Material B1 Wall/Plate 4-1/4" x 2" 496 lbs 14.4% 44.1% Hem -Fir B2 Wall/Plate 4-1/4" x 2" 496 lbs 14.4% 44.1% Hem -Fir BC FloorValue® Summary BC FloorValueO: Subfloor: 3/4" OSB, Glue + Nail Minimum Enhanced Premium Subfloor Rating: Premium Controlling Location: 06-00-00 Notes Design meets User specified (U360) Total load deflection criteria. Design meets User specified (U480) Live load deflection criteria. Design meets arbitrary (1") Maximum Total load deflection criteria. Calculations assume member is fully braced. BC CALCO analysis is based on IBC 2015. Composite EI value based on 3/4" thick OSB sheathing glued and nailed to member. Design based on Dry Service Condition. Page 1 of 1 Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALCO, BC FRAMER@ , AJSTM, ALLJOISTO , BC RIM BOARD TM, BCI@) , BOISE GLULAMTM' BC FloorValue@ , VERSA -LAM@, VERSA -RIM PLUS@ ,