2020.0023 204 SE Railroad Ave. Yelm Permit SetSHEET INDEX SITE SITE PLAN - SHEET INDEX A-1 FOUNDATION PLAN - DETAILS A-2 FIRST FLOOR PLAN - STRUCTURAL NOTES A-3 SECOND FLOOR PLAN - SHEAR WALL SCHEDULE A-4 'A' SECTION - '5' SECTION A-5 WALL TYPES - ASSEMBLIES A-6 UPPER FLOOR / LOWER ROOF FRAMING PLAN - DETAILS A -i UPPER ROOF FRAMING PLAN - FRAMING DETAILS A-8 APA PORTAL FRAME - ROOF PLAN - ELEVATIONS A-9 GENERAL NOTES - NAILING SCHEDULE - WINDOW INSTALLATION DETAIL - WATER HEATER SUPPORT DETAIL g� Q�01? / 410' PLANTING / / I / I / I I6' DRIVEWAY / I 10, � I W PLANTING ? 16' DRIVEWAY i O I U) I Lu \ I U PLANTING �..000 0n rn 16' DRIVEWAY \ I Z Q O Z J � z \ Q w \ \ / o � " w \ \ /// w Lu co PLANTING \ \ / O Z J ";j - LU L M Q p o / i o co / \ / Q cY3 \ 10, REAR YARD a� \ X <�tifi mss, Q� �y �� �� �� SITI PLAN 0� SGALE. 1/8" = 1'-m" �O NOTE:- yti cn SEE CIVIL D f;RAWINC S FOS' 3 1 lOfRE INFOfR1„IAT ION 43 ui 0 n m d U U Q L1-{ m 3 0 0 m 0 C6 W N VJ � O � �w � U � ~ �Q CSN N N a z 0 z 0 d CV � 0 SHEAR WALL —{ CALL -OUT SEE PLAN I• 2x6 STUDS -9 16" O.C. SHEAR WALL EDGE NAILING 1/2" EXPANSION JOINT GONG. SLAB s SIM. a� ? FIN. G (2) *4 CONI O C-,\ P.T. DM 2x6 MUD SILL w/ 5/84 A.B. w/ 3x3x1/4 fE WASHERS a 48" O.C. 12" MAX. FROM COMERS AND SPLICES NOUS CONG. SLAB SEE PLAN R-10 INSULATION 4-4 VERT. 6 18` O.C. ALT TAILS (2) *4 CONT. -9 BOTTOM 5" 6" 5" 16" 1 Typ. ra GARAGE 1/2" EXPANSION JOINT GONG. SLAB SEE PLA1 XtrmfRIOR PNO. DET. SCALE: 1"=1'-0" HOUSE GONG. SLAB SEE PLAN NOTE: FOR NOTES IN COMMON SEE DET. 10 5" 6" 5" 16" 4�RAGrmT 0 HOUSmc.)rm T. SCALE: 1"=V-0" C. 0 ���L1-7S1 SCALE: 1"=1'-0" SEE v 1'-E CO ANI DRIVEW� *4 fit 32" (2) 04 CC 1/2" PLWD. RISER 3/4" PLWD. TREAD A35 CLIP STRINGER TO GONG. w/ 0.111 PINS AND 084" SCREWS TO STRINGER GONG. SLAB SEE PLAN N � m PROVIDE X15 FELT BELOW STRINGER O FTG. m CSAR. DR. OPENING O ROLLED EDGE g PORCH HI /STAIR STRINGER CUT FROM 2x12 OR 111/8" RIM MATERIAL N J2cq - I rR-10NSULATION (2) 04 CONT, w/ 24" MIN. LAP SPLICES 1211 =RNSID FTG. Is STAIR SCALE; 1"=V-011 FOUNDATION PLAN SHEAR WALL CALL -OUT SEE PLAN 2x STUDS 6 16" O.0 1/2" DIA. A$. w/ 3"x3"xl/4" I£--\ WASHERS 9 48" O.C. GONG. SLAB SEE PLAN OT J2 1 16" (2) *4 CONT. w/ 24" MIN. LAP SPLICES HICKIN10 FOOTING SCALE: 1"=V-0" U M ti 1 O co I� J 26'-10" 26' -II" 26'-11" L I'-211 8'-8" 1'-211 7' -II" 8' 1'-2" 8'-8" 1'-2" 7'-11" S' 1'-2" S' -S" 1'-2" 7'-11" eP N � co m (o N ca L 6 a� M �n CIO L C 6 W W Q� a� CCf cn A-1 L 1'-6"xI'-6"x12" THICK CONC. FTG. w/ (3) *4 E.W. AND P566 BASE TYP. �+ U A -I z Q 4 e QUN A -I J UP ::D U N Z W za ®� 4" THICK GONG. ® SLAB o/ � F ® 4" THICK GONG. ® SLAB o/ Lu L F ® 4" THICK GONG. SLAB o/ N _ H W _ r 1 COMPACTED O GRAVEL. N cr LL COMPACTED O GRAVEL. cA COMPACTED O GRAVEL. N N Z IJI ti II rFF J W co Co 0 I�I C:> 7 I~I o co M I SIM. I SIM. I SIM. A-1 3 A-1 A -I 3 A-1 A -I I A-1 4" THICK GONG. SLAB w/ 6x6 WIAxWIA W.W.F. AT CENTER OF 4" THICK GONG. SLAB w/ 6x6 WIAxWIA W.W.F. AT CENTER OF =� 4" THICK GONG. SLAB w/ 6x6 W1.4xWIA W.W.F. At CENTER OF ^ ^ SLAB o/ (o MIL. MOISTURE a), SLAB o/ 6 MIL. MOISTURE SLAB o/ 6 MIL. MOISTURE BARRIER, R-10 INSULATION AND BARRIER, R-10 INSULATION AND BARRIER, R-10 INSULATION AND COMPACTED GRAVEL. COMPACTED GRAVEL. COMPACTED GRAVEL. I 12" 12" 2 -0 x2 -0 xI2 THICK GONG. FTG. w/ (3) 04 E.W. S � N 16 2 -0 x2 -0 xI2 THICK 'r- GONG. FTG. w/ (3) #4 E.W. S � N 16 2 -0 x2 -0 x12 THICK ' GONG. FTG. w/ (3) 04 E.W. 8 -� N N ,A-1 ® 2'-6"x2'-6"xI2" THICK A-1 GONG. FTG. w/ l3) �4 E.W.GONG. ® ® ® 2' -6"x2' -6"x12" THICK A -I FTG. w/ l3) °4 E.W.CONC. ® ® 2' -6"x2' -6"x12" THICK FTG. w/ (3) 04 E.W. IJ �®� IJ 0 0 0 I u u IJ O O O ° I 1 L 000 g 0 0 ❑❑ 0 0 0 ol 3'-10" 41J211 12'-10" 6' 3' -II" 4' 2" 12'-10" 6' 3'-11" 4' 2" 12'-10" ol 6' lo lo CIA s s s A-1 A-1 A -I �n r �r u u u 2 2 2 A -I 7 A -I 4" THICK GONG. SLAB w/ 6x6 i A-1 4" THICK GONG. SLAB w/ 6x6 `'� 7 4" THICK GONG. SLAB w/ 6x6 II 6 TYP. A-1 WI.4xWI.4 W.W.F. AT CENTER OF SLAB o/ 6 MIL. MOISTURE A-1 BARRIER AND COMPACTED W1.4xWIA W.W.F. AT CENTER OF SLAB o/ 6 MIL. MOISTURE A-1 BARRIER AND COMPACTED W1.4xWIA W.W.F. AT CENTER OF SLAB o/ 6 MIL. MOISTURE BARRIER AND COMPACTED 16" TYP. GRAVEL. GRAVEL. GRAVEL. LINE OF GONG FTG. O O OL LINE OF GONG. CURB O 0 A N I SIM. a, A -I Cn I SIM. a), A -I "x3' fn I SIM. in A-1 Cn "x3'-"xI2" A'-71 3'-6 6 -"x12" THICK 3' -"x3' -6"x12" THICK 6 Y-6 6 THICK 4 GONG. FTG. w/ (5) 04 E.W. GONG. FTG. w/ (5) 04 E.W. GONG. FTG, w/ (5) 04 E.W. `r 4" THICK GONG.F SLAB o/ w 2'-10" 4" THICK GONG. I�' SLAB o/ ui 2'-10" 4" THICK GONG. I�' SLAB o/ iu H2-" ol Il' - L i° COMPACTED 0 GRAVEL. i 4 LINE OF GONG FTG. lo COMPACTED O GRAVEL. �N 4 LINE OF GONG FTG. COMPACTED O GRAVEL. N 4 A-1 LINE OF GONG. CURB A-1 LINE OF GONG. CURB A-1 "xI'-6"x12" THICK__jl A1C. FTG. w/ (3) 04 E.W. (o A -I PF. 5 PF. A-8 A -I A-8 6 A -I PF, 5 PF. A-8 A-1 A-8 6 A -I PF. 5 PF. A-8 A -I A-8 PB66 BASE 2 -4 15'-31, 2 -3 2 -4 15'-3" 2 -3 2 -4 15'-31, 21-311 26'-10" 26' -II" 26'-11" 1/2" PLWD. RISER 3/4" PLWD. TREAD A35 CLIP STRINGER TO GONG. w/ 0.111 PINS AND 084" SCREWS TO STRINGER GONG. SLAB SEE PLAN N � m PROVIDE X15 FELT BELOW STRINGER O FTG. m CSAR. DR. OPENING O ROLLED EDGE g PORCH HI /STAIR STRINGER CUT FROM 2x12 OR 111/8" RIM MATERIAL N J2cq - I rR-10NSULATION (2) 04 CONT, w/ 24" MIN. LAP SPLICES 1211 =RNSID FTG. Is STAIR SCALE; 1"=V-011 FOUNDATION PLAN SHEAR WALL CALL -OUT SEE PLAN 2x STUDS 6 16" O.0 1/2" DIA. A$. w/ 3"x3"xl/4" I£--\ WASHERS 9 48" O.C. GONG. SLAB SEE PLAN OT J2 1 16" (2) *4 CONT. w/ 24" MIN. LAP SPLICES HICKIN10 FOOTING SCALE: 1"=V-0" U rpt] - M ti 1 O co I� J L E O�ObbH � eP rpt] - 05 0— o M ti 1 O co Ca L E M co N � co m � N ca L Q a� M �n CIO L C W W Q� a� CCf cn cit L _ U �+ U Z z Q U _o QUN 05 0— o CIO Ca L E U_ N � � N O Q M �n U � W co O "Nco Z O VJ _ — Of � (7 �+ W Cn Z z Q U _o QUN J UP ::D U LL Q Z W za z H W W 0 cr LL H U Z IJI ti II J W co Co 0 I�I C:> 7 I~I o co M Ca L E N N � � N O Q U � L co O "Nco o _ — Of 0- . �+ W Cn CD U _o QUN UP za z 0 STRUCTURAL NOTES General Notes: These structural notes supplement the drawings. Any discrepancy found among the drawings, these notes, and the site conditions shall be reported to the Engineer, who shall correct such discrepancy in writing. Any work done by the Contractor after discovery of such discrepancy shall be done at the Contractor's risk. The Contractor shall verify and coordinate the dimensions among all drawings prior to proceeding with any work or fabrication. The Contractor shall coordinate between the architectural drawings and the structural drawings. The architectural dimensions are taken to be correct when in conflict with the structural drawings. The Contractor is responsible for all bracing and shoring during construction. All construction shall conform to the applicable portions of the latest edition of the International Building Code except where noted Desi_grr Criteria: 1. Live Load = 40 PSF (Floors) = 60 PSF (Decks) = 25 PSF (Snow) 2. Dead Load = 15 PSF (Roof) = 12 PSF (Floor) = 10 PSF (Deck) = 10 PSF (Walls) = 150 PCF (Concrete) 3. Partition = 10 PSF (Floors) 4. Wind = 2015 IBC Exposure B @ 110 mph 5. Earthquake - 2015IBC Site Class = D Design Cat. = D Use Group - I R = 6.5 Cd = 4 Wo = 3 6. Soil = 1500 PSF, Assumed bearing capacity = 38 PCF. Assumed Active Fluid Pressure - 350 PCF, Assumed Passive fluid Pressure = 0.45, Assumed Coefficient of Friction = 110 PCF, Assumed Soil Density Concrete & Reinforcincr Steel., Steel. 1. All concrete work shall be per the 2015 IBC Chapter 19- 2- All reinforcing shall be ASTM A615 Grade 60 except as shown on the plans. 3. Concrete shall be in accordance with ASTM 150. f'c = 2500 PSI @ 28 day slump = 4" maximum, 6% Air entrained. 4. Garage slab and exterior slabs to have minimum thickness of 4" with 6x6 W1 _4x1A WWF with vapor barrier. This is at the owner's option to reduce slab cracking. Crack control joints the responsibility of the contractor 1. Anchor bolts shall be ASTM A307. Carpentry: 1. 2X structural framing shall be #2 Douglas Fir. 4x structural members shall be #2 Douglas Fir. 6X members shall be #1 Douglas Fir. 2. Provide solid blocking in floor system below all bearing walls and point loads. 3. 2X joists shall be kiln dried and stored in a dry area prior to installation. The moisture content of all wood shall be less than 15%. 4. Floor joists shall be by Boise Cascade or other approved manufacturer. Joist to be installed and braced per manufacturer's requirements. 5. Roof trusses shall be by a pre -approved manufacturer and constructed according to the specifications of the Truss Plate Institute. Truss shop drawings must be stamped by a licensed engineer and be on site at the time of construction. Preliminary truss drawings must be reviewed prior to construction. It is the truss manufacturer's responsibility to inform the engineer of record of any changes from the preliminary truss lay -out. Girder trusses to have a minimum of bearing studs equal to number of plies of truss. All girder trusses shall have Simpson HGT tie down at either end to match number of plies. Truss manufactures are responsible for all bracing of the trusses including end wall bracing and all other bracing between the building and the trusses unless specifically shown otherwise on the drawings. Contractor to coordinate bracing with engineer of record as required. 6. Glue laminated beams shall be 24F -V8 for cantilevered or continuous beams and 24F -V4 for simple spans. (Fb = 2,400 PSI) (Fv = 190 PSI) (E = 1,800,000 PSI) (FcL = 650 PSI) 7. Continuous and cantilevered glue laminated beams shall not be cambered. All other glue laminated beams shall be cantilevered for L1480. See the framing plans for any exceptions. 8. All manufactured lumber shall be by Boise Cascade and have the following structural properties: Versa Lam (VL) (Fb - 2,800 PSI) (Fv = 280 PSI) (E = 2,000,000 PSI) (FcL = 750 PSI) 9. Sheathing at roof and floor shall be laid with face grain perpendicular to supports and end joints staggered 4'-0" on center. Provide 118" space at panel edges as required by panel manufacturers. Floor sheathing shall be nailed 6" c.c. edges and 12" field with 10d's and roof sheathing shall be nailed 6" o.c. edges and 12" o.cfield with 10d's unless otherwise noted on the drawings. 10. Block and nail all horizontal panel edges at designated shear walls. 11. All beams to be supported by a minimum of a solid post that matches the width of the wall and the width of the beam unless noted otherwise. A 6x beam bearing in 2x6 wall will be a 6x6. Provide solid squash blocking to match in floor system and match post size in foundation. Contact Engineer of record for any deviations. 12. All fasteners in contact with pressure treated lumber will meet the below requirements. All fasteners including nuts and washers in contract with pressure treated lumber shall be hot -dipped zinc coated galvanized steel, stainless steel, silicon bronze or copper. Fasteners other than nails, timber rivets, wood screws and lag screws shall be permitted to be of mechanically deposited zinc coated steel in accordance with ASTM B 695, Class 55 minimum. Fasteners exposed to weather must meet the requirements of the pressure treating manufacture's minimum. IN ADDITON, the contractor shall coordinate connector/fastener coating requirements with recommendations from connector/fastener manufacturer and type of pressure treating chemical and retention being used. See Section 2304.10.5 of the 2015 IBC for additional information. 13. All GWB to be installed perthe IBC and Gypsum Association's publication for the Application and Finishing of Gypsum Board, GA -216 Hardware: All connection hardware shall be Simpson "Strong Tie Connection hardware exposed to the weather or soil shall be treated as in steel above. CAUTION: PLACE TRUSSES PER MANUFACTURER'S RECOMMENDATIONS AND BRACE PER TRUSS COMPANY RECCOMENDATIONS. CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY BRACING AND SHORING REQUIRED FOR PLACING TRUSSES. NOTE THESE DRAWINGS DO NOT INCLUDE ANY TEMPORARY SHORING OR BRACING. PRECISE ENGINEERING RECCOMENDS ALL SHORING AND BRACING BE DESIGNED AND DETAILED BY A LISENCED ENGINEER. CONTRACTOR TO FIELD VERIFY ALL CONDITIONS AND ALL ELEVATIONS. as v 42" HI. RAISED BAR 195 SQ. FT. / UNIT 0 O DRL 5(1 W/ G . D.W. SMOKE PETEGTOR NOTE: ALL SMOKE DETECTORS TO BE CARBON MONOXIDE DETECTION EQUIPPED AND INTERCONNECTED w/ BATTERY BACKUP. aTYPICAL SHEAR WALL CALL OUT SEE SHEAR WALL SCHEDULE O TYPICAL HOLDOWN CALL OUT SEE HOLDOWN SCHEDULE STAIR NOTE: MAX RI5E TO BE 13/4" MIN. RUN TO BE 10" 1 1/2" DIA. HAND RAIL BETWEEN 34" AND 38" ABOVE THE STAIR NOSE. MIN. WIDTH OF STAIR TO BE 36" CLEAR AND OPEN BALUSTERS TO BE PLACED SUCH THAT A 4" DIA. SPHERE MAY NOT PASS BETWEEN TYP. FrZvUwm ENERGY COMFL IANC (MEDIUM DWELLING UNIT: 35 CREDITS REQUIRED) la RIO -2' BELOW SLAB AND U-024 WINDOWS (05) 3d HIGH EFFICIENT H.V.A.C. 3d (1.0) 5a EFFICIENT WATER HEATING 5a (05) 5c EFFICIENT WATER HEATING 5c (15) 3.5 CREDITS PROVIDED 42" HI. RAISED BAR 195 SQ. FT. / UNIT 0 0 0 F0 RE 6D.W. w/ G . 1,090 SQ. FT. / UNIT AREA TABULATION FIRST FLOOR PLAN = 195 SQ. FT. / UNIT SECOND FLOOR PLAN = 1,090 SQ. FT. / UNIT TOTAL HEATED SPACE = 1085 5Q. FT. / UNIT GARAGE = 315 SQ. FT. / UNIT COVERED ENTRY = 31 SQ. FT. / UNIT COVERED PATIO = 44 SQ. FT. / UNIT FIRST FLOOR PLAN, fD m 0 0 M ti o co � J M Ui L � O�ObbH � eP M 05 05 0- 0 ti o co C6 M Ui L � U_ 00 N W aD a� E N Z L M Q LJJ aD rn C .� W U W O a� 0 x VJ L A.- Q w W ZD J � 0 U 05 05 0- 0 LL 0 a a� 0 Q f a m Ln 0 N 0 N \ N \ 0 zs v Ln a� a i= v a� Q 0 w Ln 0 N E a� rl- N 0 O N H U) C6 Ui L � U_ N N 40 E N Z M Q LJJ aD rn 23 Q O 0 x co1 ♦V Zz Q w W ZD J � 0 U LL Z Lu _ O UN U u a Lu ze N� Lu tY 0 ,c/) Ll � U z IC7� z J Z LU M � O CD, O co co LL 0 a a� 0 Q f a m Ln 0 N 0 N \ N \ 0 zs v Ln a� a i= v a� Q 0 w Ln 0 N E a� rl- N 0 O N H C6 L � N N 40 E N Z Q C/) L O 0 x co1 ♦V CL w -Q _ UN u a ze N� 0 z � Q 0 LL 0 a a� 0 Q f a m Ln 0 N 0 N \ N \ 0 zs v Ln a� a i= v a� Q 0 w Ln 0 N E a� rl- N 0 O N H TYPICAL SHEAR WALL NOTES Use 5/8" dia. by 10" Anchor Bolts (AB's) with single plates and 5/8" dia. by 12" AB's with double and 3x plates spaced as shown on the drawings. AB's shall have 7" of embedment into footing, shall be centered in the stud wall, and shall project through the bottom plate of the wall and have a 3x3x 114 plate washer. There shall be a minimum of two bolts per piece of sill located not more than 12 inches or less than 4 inches end of each piece. Anchor bolts to be galvanized per the below requirement (Fasteners in contact with pressure treated lumber). At existing foundation use 5/8" diameter Simpson Titen HG bolts with minimum of 4" embedment into the existing concrete. All wall sheathing shall be 1/2" CDX plywood, 5/8" T1-11 siding, or 7/16" OSB with exterior exposure glue and span rated "SR 24/0" or better. All free sheathing edges shall be blocked with 2x4 or 2x6 flat blocking except where noted on the drawings or below. All nails shall be 8d or 10d common (8d common nails must be 0.131 inch diameter, Senco KC27 Nails are equivalent. If 10d common nails are called for the diameter must be 0.148 inches, Senco MD23 Nails are equivalent). Nail size and spacing at all sheathing edges shall be as required below or as in the drawings. Nail spacings shall be 12" o.c. for all field nailing except as noted. Hold downs are Simpson "Strong Tie" and shall be installed per the manufacture's recommendation. Equivalent hold downs by United Steel Products Company "Kant -Sag" that have 1CBO approval can be substituted in place of Simpson hold downs. All floor systems must be blocked solid below member that the hold down is attached to. This block should be equal to or larger than the member the hold down is attached to and be placed as a "squash block". All double and triple studs shall glued and nailed together with 10d's at 3" o.c. for each layer. All 4x studs are to be #2 DF and all 6x studs are to be #I DF when used for hold downs and shear walls. FASTENERS IN CONTACT WITH PRESSURE TREATED LUMBER All fasteners including nuts and washers in contract with pressure treated lumber shall be hot -dipped zinc coated galvanized steel, stainless steel, silicon bronze or copper. Fasteners other than nails, timber rivets, wood screws and lag screws shall be permitted to be of mechanically deposited zinc coated steel in accordance with ASTM B 695, Class 55 minimum. Fasteners exposed to weather must meet the requirements of the pressure treating manufacture's minimum. IN ADDITON, the contractor shall coordinate connector/fastener coating requirements with recommendations from connector/fastener manufacturer and type of pressure treating chemical and retention being used. See Section 2304.10.5 of the 2015 IBC for additional information. ALL WALL STUDS AND ROOF TRUSS TOP CHORDS AND SECONDARY FRAMING LUMBER SHALL BE DOUG -FIR #2 OR BETTER. NOTE: MST STRAPS attaches to (2) 2x or 4x studs in wall above and below unless noted otherwise. Nail all holes with 16d sinkers. Double studs may be use as a substitute for 3x nominal framing call out below. Studs MUST be glued and nailed together with (2) lines of 10d's at 3" on center staggered. Horizontal blocking for shear walls nailed with 8d's shall be minimum of 2x flat and shear walls nailed with 10d's shall be minimum of 3x flat. SHEAR WALL SCHEDULE Al sheathing nailed with 8d's at 6" on center all edges. A2 sheathing nailed with 8d's at 4" on center all edges. HOLD DOWN SCHEDULE It is the responsibility of the contractor to locate hold down anchor bolt to accommodate all structural framing. Anchor bolt to be located nearest the corner or opening at the end of the shear wall. All foundation vents to be a minimum of 12" off centerline of the anchor bolt on either side. Holdown stud to be coordinated with shear wall panel edge framing requirements. Larger stud size controls For holdown anchor bolt embedment greater that foundation depth, thicken footing for 2'-0" either side of holdown anchor bolt to a depth that provides for 3" clear below the bottom of the anchor bolt. Provide (2) additional #4 x 3'-0" pieces of longitudinal rebar at this location. O HD U2 attaches to concrete foundation with a Simpson SSTB 16. HDU2 attaches to double 2x studs or 4x or 6x stud with (6) Simpson SDS 1/4 X 3 Wood Screws in wall above. lo M ti o 13'-2" c6 13'-S"-2" E W00co 13'-S" 1" 13'-2" -� EZ 3 N Q CU 0 CTJ UJ O co 0- L A U }+ U d QUN1yU` ^CD in O) I I z M� W-2 1 iiZS a � Q I W-2 I 4 I W-2 I 5040 EGRESS 5040 EGRESS 5040 EGRE56 5040 EGRE56 5040 EGRESS 5040 EGRESS W-2 W -I W-3 W-1 W-3 W -I W-2 5EDR I. 2 1 1 3 5EDRM. 2 1 1 SED I I3 5EFDRM. 2 N — 1 . N 10' 3'-2" 011 3'-6" 10'-2" 10' ol 3'-2" L. 3'-6" 10'-2" 10' 3'-2" 3'-6" 10'-2" 1 lo SMOKE DETECTOR lo SMOKE DETECTOR lo SMOKE DETECTOR SMOKE DETECTOR SMOKE pETEGTOR SMOKE pETEGTOR (2) 3068 51-PA56 CADET CADET (2) 3068 51 -PASS (2) 3068 5I-PA55 CADET CADET (2) 3068 51-PA55 (2) 3068 51-PA66 CADET CADET (2) 3068 51-PA55 `V 54P � NQ S4P 64P 64P S4PID ID 64P `V N N N N N N T -' 0 fl- I /� FAN MIN r W-1 = �f 1 50 GFM HALL I IALL FAN MIN W-1 = �f 50 CFM � /� FAN MIN. W-1 = �f l --t 50 GFM HALL 0 N DETECTOR LINEN S R E N DETECTOR LINEN 6 R E N DETECTOR LINEN S R OILET Cq _ 3'-8" 3'-8" m 3'-6" 2'-4" 5'-4" 3' " 2'-6" 2'-7" 3'-8" 3'-S" Cn 3'-6" 2'-4" 5'-4" 3' " 2'-6" 2'-i" 3'-S" 3'-S" cn 3'-6" 2'_4" 5'-4" 3' " 2'_6" 2'-i" 0 ^ M z 1/2 WALL z 1/2 WALL z 1/2 WALL N STOP. FOR � o � N 5�®�. A N 'cr N LA N � r N �A N � •� N LA cf) — 22x3 ATTIC ATTIC 5. 2 ATTIC W. fY o W. 0 W. m ACCES OQ FAN MIN. 50 CFM ua OW -4 M AGGES FAN MIN. 50 CRN 11J-4 ACCES LL FAN MIN. 50 CFM W-4 tr O SMOKE �0 D• N �U FAN MIN. 50 GFM TOILE GO \0 SMOKE D N - f11 � �U FAN MIN 50 GFM TOILE fA \p ►n SMOKE � 0 D N ` [I1 � � O �U FAN MIN. 50 GFM TOILE fA \4 DETECT CADET CADET •� `� DETECTO N `" CADET CADET r N DETECT N �" CADET GDT t N � CADET \Q CADET \Q CADET N SMOKE N SMOKE N SMOKE I DETECTOR PROVIDE NOT AND COLD W -I DETECTOR PROVIDE NOT AND COLD W-1 DETECTOR PROVIDE NOT AND COLD W-1 NOSE BIBS FOR AUTO NOSE 5155 FOR AUTO NOSE 5155 FOR AUTO WASHER AND VENT FOR WASHER AND VENT FOR WASHER AND VENT FOR DRYER PROVIDE DRAIN 1._8,. DRYER. PROVIDE DRAIN I._8„ DRYER PROVIDE DRAIN FOR WASHER FOR WASHER FOR WASHER N M � W-1 3- a 01 N N 1830 Fn 1830 FJ3 1830 F.G. I 5040 EGRESS FF Z 1 5040 EGRESS I I 5040 EGRESS I r 1 W-2 I 1 I <W-2 1 W-2 1 v M I i'-6" 3' l'-6" 3' l'-6" 3' 10'-6" 13' 3'-4" " 11110'-6" 13' 3'-4" " 11110'-6" 13' " 3'-4 lir 7r SO'-Sn Ir SMOKE IDETECTORI NOTE: ALL SMOKE DETECTORS TO 5E CARBON MONOXIDE DETECTION EQUIPPED AND INTERCONNECTED w/ BATTERY BACKUP. SCALE: 1/4" = 1'-0" 0 co Z O Z LU L� M ti o c6 L E W00co 00 N -� EZ 3 N Q CU 0 CTJ UJ O co 0- L A U }+ U d QUN1yU` ^CD in O) d a Z O Z LU L� N r O O N H c6 E (D N -� N Q U C) 0 CTJ _ O co 0- o }+ LU U) d QUN1yU` ^CD in O) d a ze z M� iiZS a � Q 0 N r O O N H m d d m U 1/16" O.S.B. ROOF SHEATHING m PRE-ENGINEERED s TRUSSES 24" O.C. 0 0 C 0 0 ROOF LINE BEYOND I A-1 WALL LINE _ Lo., < BEYOND O 0,� rno 'COO BATT. INSULATION R-1 6�s o�`` R-21 BATT. INSUL. OjObbH ee 2x6 STUDS 6 16" O.C. l/I6" O.S.B. WALL SHEATHING - W-25EW-2 U.I. �IRM3 . Ac -) 1/16" O.S.B. ROOFYam SHEATHING ti 0 PRE-ENGINEERED FLOOR SHTG. SEE PLAN c9 5 SIM. TRUSSES 6 24" O.C. FLOOR JOISTS SEE PLAN = s FLOOR LINE BEYOND ROOF BEYOND A-6 c i 00 w 11/2" DIA. HAND RAIL i ca 1/2" PLWD. RISER cu 5/6" TYPE 'X' G.W.B.uj BEAM SEE PLAN 3/4" PLWD. TREAD BELOW USEABLE F -I .� U STAIR AREA w (D i HEADER SEE PLAN 65 S I AIR POWDER �REAT R®®� P.T. POST BEYOND V U WALL LINE BEYOND - � °D SEE PLAN ol o \/ *It ` cn COV. �I�l I �� "� m 2x(o STUDS m 16" O.C. W-2 STAIR STRINGER GUT OPEN BELOW LINE OF W-4 FROM 2x12 OR 111/811 STAIR DOOR IN CONC. SLAB SEE PLAN RIM MATERIAL FOREGROUND GONG. SLAB SEE PLAN 7 8 U) 6 I SIM. A -I A-1 S -I 1 %� I O� w A -I A -I A -I �(■� I U SCALE: 3/8" =l'-011 \ 7/16" O.S.B. ROOF SHEATHING PRE-ENGINEERED TRUSSES 24" O.C. /� UJ °° Z U) rn O z z Q J W iE O.S$. ROOF U SHEATHING � Z W G.W B. DRAFT STOP G U1 B. DRAFT STOP 0 U PRE-ENGINEERED TRUSSES 6 24" O.G. Z C) W 0 A-1 W w C/) Ln Lnz W ";j - LU W Co 4 z 0 , o Q A_co R-38 BATT. INSULATION 4 4 6 Q o M A-6 A-6 R-ILn HALL 5.1 HALL E3, I k4LL W-3 W-3 W -I DOOR OPENING BEYOND 2x6 STUDS a 16" O.C. R-21 BATT. INSUL. FLOOR SHTG. SEE PLANco 1/16" O.S B. WALL SHEATHING FLOOR JOISTS SEE PLAN W-2Ln W-2 F -I W-1 4 4 A-6 A-6 W-2 W-1 W-3 4— <TCHEN <TCHEN SFT. Rid. <TCHEN >y 5E NrONID co CONC. SLAB SEE PLAN 3 413 S-1 3 3 SECTION , a A -I A-1 SCALE: 3/8" =l'-011 A-1 L N N U < LL 0 a a� 0 Q a N 0 N 0 N 0 N \ N 0 3 v a� a E v } a� Q 0 Lu L rn x �w � � U _ ~ oQ UN N � d Z 0 0 Z � Q 0 N O 0 N H 5/8" G.W.B. 111 /-I in / A Ifl Cen A,—n) S. FOR SHTG. 6 SIM. D TO STUDS 3 WARTY WALL ATTIC ASWIBLY 1" CLR (AIR SPACE) SCALE:1"=1'-0" R-21 5 5/8" G. FLOOR FLOOR DIREC' 5/8" G.W.E IED TO STUDS :)5a1611O.G. EE PLAN IED TO STUDS 2 PARTY WALL FLOOR/01104 ASWIBLY I" CLR (AIR SPACE) 5CALE:I"=1'-011 5/8" G.W GONG. S OI PARTY WALL TO FOOTING D TO STUDS 6 16" O.C. FLOOR SHEATHING SEE NOTE FLOOR JOIST SEE PLAN R-38 BATT. INSULATION 01 O FLOOR /CEILING OVER GARAGE ROOF 455EML E 5 1./ D E 6GR I PT I ON FIRE RATING RATING SOURCE SOUND RATING RATING SOURCE 5=1 3/4" T4G PLYWD. FLOOR SHEATHING I HOUR G.A. FILE FC 45-49 STC GYPSUM _ ASPHALT COMPOSITION ROOFING (CLASS 1 HOUR 55032 SOUND TRANS 2 5 CIIEDITION CEILING FLOOR JOIST SEE PLAN NR 120.1 ITEM #21 ESTIMATED NR FLOOR / UNDSERLAYMENT W/ 60% OVERLAP OVER O ca H ` 0 CEILING tv R-30 BATT. INSULATION 72 z z Q 0 GARAGE MANUR ROOF TRUSS a 24" O.C. J ZD U 0 Z Lu BASE LAYER 1/2" PROPRIETARY TYPE 'X' GYPSUM 0 �/ U z III W - 2 WALLBOARD OR VENEER BASE APPLIED AT RIGHT H uJ 0 0 Z � C Lu0 ANGLES TO RESILIENT CHANNELS SPACED 12" O.G. NR N/A NR NR TYP. w/ I" TYPE 'S' DRYWALL SCREWS SPACED 8" O.C. z 1 z EXTERIOR AT END JOINTS AND 16" O.G. IN THE FIELD OF THE NA NA N/A N/A WALL PANEL. RESILIENT CHANNEL APPLIED a RIGHT O � 1 )co M / CEILING ANGLES TO A MINIMUMS 1/2" DEEP PROPRIETARY ASSEMBLY WOOD I -JOISTS SPACED 16" O.C. w/ 13/4" TYPE 'W' DRYWALL SCREWS. FACE LAYER 1/2" PROPRIETARY TYPE 'X' GYPSUM BOARD OR III W - 3 GYPSUM VENEER BASE APPLIED AT RIGHT ANGLES TO RESILIENT CHANNELS WITH 15/8" TYPE 'S' TYP. UNIT SCREW 10 6" O.G. AND 1 1/2" TYPE 'G' DRYWALL SEPERATION SCREWS 6 8" O.G. AT BUTT JOINTS LOCATED MID WALL SPAN BETWEEN RESILIENT CHANNELS. ROOF 455EML E 5 WALL A55EM5L IE5 DESCRIPTION FIRE RATING RATING SOURCE SOUND RATING RATING SOURCE 5=1 E RATING SOURCE RATING SOURCE TYP. ROOF / ASPHALT COMPOSITION ROOFING (CLASS 1 HOUR IBC TABLE N/A N/A CEILING A) OVER I LAYER OF ROOFING NR 120.1 ITEM #21 NR NR HEATED UNDSERLAYMENT W/ 60% OVERLAP OVER O ca H ` 0 SPACE ROOF SHEATHING PER STRUCTURAL z z Q 0 W� ZD MANUR ROOF TRUSS a 24" O.C. J ZD U 0 Z Lu 2" AIRSPACE 0 �/ U z III W - 2 BAFFLE CARD H uJ 0 0 Z � C Lu0 VENTED BLOCKING NR N/A NR NR TYP. R-49 BATT z 1 z EXTERIOR INSULATION NA NA N/A N/A WALL A55EM5L IE5 FLOOR / CEILING 455EMBL IE5 D E 5CR I PT I ON FIRE RATING SOUND RATING 5=1 E RATING SOURCE RATING SOURCE UJ = 2" RIGID INS. UNDER ENTIRE SLAB AT HEATED SPACES U TYP. 2x4 STUDS 4x1 16" O.C. U.N.O. ON PLAN NR N/A NR NR INTERIOR U) O ca H ` 0 WALL CONC, SLAB SEE STRUCTURAL z z Q 0 W� ZD 1/2" G.W.B. EA. SIDE J ZD U 0 Z Lu SIDING PER ELEVATION (COORDINATE SUBSTRATE 0 �/ U z III W - 2 PER BELOW) OVER ONE LAYER WEATHER H uJ 0 0 Z � C Lu0 RESISTIVE BARRIER W/ 60% OVERLAP NR N/A NR NR TYP. "UNDERLAMENT" OR "SINGLE FLOOR" FINISH z 1 z EXTERIOR SHTG, PER STRUCTURAL NA NA N/A N/A WALL PERPENDICULAR WITH FLOOR JOISTS STAGGERED. O � 1 )co M / CEILING 2x6 STUDS s 16" O.C. UN.O. ON PLAN PER ASSEMBLY STRUCTURAL 1/2" GW$ w/ P.V.A. PRIMER (PERM PAINT) R-21 BATT INSULATION III W - 3 1/16" O.S$. ONE LAYER 5/8" TYPE X GYPSUM WALLBOARD OR GYPSUM SHEATHING SEE PLAN VENEER BASE APPLIED PARALLEL OR AT RIGHT ANGLES TO EACH SIDE OF DOUBLE ROW OF 2x4 WOOD STUDS 16" O.C. ON TYP. UNIT SEPARATE PLATES I" APART WITH bd COATED NAILS, 11/5" SEPERATION LONG, 0.0915" SHANK, 1/4" HEADS, 1" O.C. WALL JOINTS STAGGERED 16" ON OPPOSITE SIDES. HORIZONTAL BRACING REQUIRED AT MID -HEIGHT. (LOAD-BEARING) I HOUR GA WP 45-49 STC N/A 3310 SOUND TRANS ESTIMATED 2x4 or 2x6 a 16" O.C. STAGGERED /SEE PLAN I" AIR SPACE 2x4 or 2x66 16" O.C. STAGGERED / SEE PLAN 1/16" O.S$. (1) LAYER 5/8" TYPE "X" GWB SHEATHING SEE PLAN 1/2" G.W.B. EA. SIDE PLUMBING NR N/A NR NR WALL AT SHTG. PER STRUCTURAL INTERIOR UNIT 2x STUDS 9 16" O.G. U.N.O. ON PLAN PER STRUCTURAL PLUMBING / MECH. PIPES FLOOR / CEILING 455EMBL IE5 LL 0 a a� 0 Q a 00 m 0 N 0 N 0 N N 0 N to a� a E v Q 0 LLI v 0 N a� r` N 0 O N H D E 5CR I PT I ON FIRE RATING RATING SOURCE SOUND RATING RATING SOURCE 5=1 E U_ N d 2" RIGID INS. UNDER ENTIRE SLAB AT HEATED SPACES U TYP. SLAB FLOOR FINISH PER PLAN NR N/A N/A N/A ON GRADE U) O ca H ` 0 CONC, SLAB SEE STRUCTURAL z z Q 0 W� ZD 4" CAPILLARY BREAK MATERIAL PER GEOTECH J ZD U 0 Z Lu REPORT I 11= 0 �/ U z 1 Z 1-11--� MOISTURE BARRIER H uJ 0 0 Z � C Lu0 19/2" WOOD STRUCTURAL PANELS, MIN. GRADE W �-�--� C/) 0 0 C) "UNDERLAMENT" OR "SINGLE FLOOR" FINISH z 1 z w FLOORING. FACE GRAIN OF PLYWOOD TO BE NA NA N/A N/A TYP. FLOOR PERPENDICULAR WITH FLOOR JOISTS STAGGERED. O � 1 )co M / CEILING ASSEMBLY 'I' JOISTS PER STRUCTURAL, SPACED 16" O.G. FIRESTOPPED 'X' 1/2" TYPE G.W.B. LL 0 a a� 0 Q a 00 m 0 N 0 N 0 N N 0 N to a� a E v Q 0 LLI v 0 N a� r` N 0 O N H U) ca m L E U_ N d U M N > UJaD rn m Z U) O ca H ` 0 z z Q 0 W� ZD J ZD U 0 Z Lu 0 �/ U z 1 Z 0 H uJ 0 0 Z � C Lu0 W �-�--� C/) 0 0 C) U z 1 LL 0 a a� 0 Q a 00 m 0 N 0 N 0 N N 0 N to a� a E v Q 0 LLI v 0 N a� r` N 0 O N H U) ca ui L E U_ N N M N > UJaD rn 0 ca Z U) O ca H x z z Q w W� ZD J ZD U LL Z Lu 0 �/ U z 1 Z 0 H uJ 0 0 Z � Q Lu0 W �-�--� C/) C) U z 1 z w Z Z > LU M ti Z I 0- 0 < O � 1 )co M LL 0 a a� 0 Q a 00 m 0 N 0 N 0 N N 0 N to a� a E v Q 0 LLI v 0 N a� r` N 0 O N H ca L E N N N > ��/U v ) 0 ca O ca d x a) w U ~ ~ N a ¢ U z L m 0 0 Z � Q 0 LL 0 a a� 0 Q a 00 m 0 N 0 N 0 N N 0 N to a� a E v Q 0 LLI v 0 N a� r` N 0 O N H A-6 Project Number Sheet Number OF Sheet Contents Project Title A Triplex for: Cynthia Schmier 204 SE Railroad Ave. Yelm, Wa. Drawn By Checked By Date Date Structural Engineer Precise Engineering Inc. 1011 Mellen Street Centralia, Wa. 98531 Ph. 360-736-1137 Reproduction or re-use of these drawings without the written permission of the Design Team is prohibited.TTARKN E NHAH.DDLORAH N E F SSIO OPR N EE NAL G IREADVANCED DRAFTING SERVICES 1011 MELLEN STREET CENTRALIA, WA. 98531 360 - 736 - 4751 PLANNING - DESIGN - DOCUMENTATION A-7 Project Number Sheet Number OF Sheet Contents Project Title A Triplex for: Cynthia Schmier 204 SE Railroad Ave. Yelm, Wa. Drawn By Checked By Date Date Structural Engineer Precise Engineering Inc. 1011 Mellen Street Centralia, Wa. 98531 Ph. 360-736-1137 Reproduction or re-use of these drawings without the written permission of the Design Team is prohibited.TTARKN E NHAH.DDLORAH N E F SSIO OPR N EE NAL G IREADVANCED DRAFTING SERVICES 1011 MELLEN STREET CENTRALIA, WA. 98531 360 - 736 - 4751 PLANNING - DESIGN - DOCUMENTATION EXTENT OF HEADER (TWO BRACED WALL PANELS) EXTENT OF HEADER (ONE BRACED WALL PANEL) AFA FC�TAL F(RAM EECi ON E CCNc7TRJC. ION (EIEC[; 5UILT THRU WALL U (4) ROOF AREA (UPPER) 3,218 SQ. FT. I. HEADER PER PLAN (MINIMUM 3"xIV4'9 2• MINIMUM (2) 2x6 STUD FRAMING TYP. 3. FASTEN TOP PLATE TO HEADER W/ 2 ROWS OF 16d SINKER 50% VENT REQ. AT SAVE 158.4 SQ. INCHES NAILS a 3" O.C. TYP. 4. 5IMP50N M5TA24 STRAP TIE HEADER TO WALL ON INSIDE Q FACE 5. FASTEN SHEATHING TO HEADER W/ 8d COMMON OR GALV. 7I a BOX NAILS IN 3" GRID PATTERN AS SHOWN 4 3" O.G. IN ALL � I..I..I FRAMING (STUDS, BLOCKING, SILLS) TYP. 6. %a" MINIMUM THICKNESS WOOD STRUCTURAL PANEL SHEATHING �• FOR PANEL SPLICE (IF NEEDED), PANEL EDGES SHALL BE L BLOCKED W/ 3x OR (2) 2x, 4 OCCUR WITHIN 24" OF MID HEIGHT. 'W^ IF 2x BLOCKING IS USED, FACE NAIL W/ (3) 16d SINKERS. 8. 5IMP50N 5THD14 STRAP TIE HOLDOWN AS SHOWN OR (HDU5) DIA. ANCHOR BOLT W/ 7 MINIMUM EMBEDMENT. USE 1/4"x3"x3" PLATE WASHER MINIMUM (10) 10. FOUNDATION PER PLAN II. SHEATHING FILLER IF NEEDED 12, 5IMP50N LSTHDS STRAP TIE HOLDOWN AS SHOWN (OR HDU4) SCALE: 3/8"=1 '-0" AREA SHALL ®®F VENT I L AT I C , BE Y3mmT;H. PER IRC 1203.2 ROOF AREA (UPPER) 3,218 SQ. FT. ROOF AREA (LOWER) 352 SQ. FT. 260 / 300 = .9 SQ. FT. 129.6 SQ. INCHES REQUIRED 655 / 300 = 2.2 SQ. FT. 316.8 SQ. INCHES REQUIRED 50% VENT REQ. AT RIDGE 64.8 SQ. INCHES 50% VENT REQ. AT RIDGE 158.4 SQ. INCHES 50% VENT REQ. AT SAVE 64.8 SQ. INCHES 50% VENT REQ. AT SAVE 158.4 SQ. INCHES P1C/`/1 �iCAIT LFT ILIVATION SCALE: 1/8" I' -O" '1POSITION �G. ROOF rERIAL )IE PANEL W/ 4" BATTS g .c. RIGHT ILIVATION SCALE: 1/8" = I'-0" LOWER ROOF LINE Lu �I z O J N L to �� I Z LLW m J U Q zl J OL SLOPE: 5:12 UPPER ROOF LINE WALL LIN BELOW LOWER ROOF LINE DRAFT STOP RIDGE LINE w/ CONT. RIDGE VENT 5:12 5:12 - UF PER ROOF LI E LOWER ROOF LINE y�-1 Lam` 5:12 5.12 5/412 TRIM HARDIE SHING. LOWER ROOF LINE 5/412 TRIM n I JI W u C m N L to �� I Z z Q J J `-6 Q co � 7I a C U � I..I..I SLOPE: 5:12 5:12 ROOF PLAN SCALE. 1/8" = I'-0" MIN mid fir; mil i"n l0MI m Im mn�� mem n�mn �mni� pv �I��I■,� 111��,■�11 MFMINMINI �I 6x6 POST 5/4x4 TRIM GARAGE DOOR FRONT ILIVATION SCALE. 1/8" = I'-0" RNAR ILIVATION SCALE: 1/8" = I'-0" M ti r, T♦ o V / cD co 61, C O O bis N L to �� O�ObbH � eQ M ti r, T♦ o V / cD co CD O Of M W 00 00 rn Q Z U— 7 II -- Lu H Lu Lu w cn U w' -;T Z _j, QJ w Mr Q M Lo (D o rn w a) `-6 co � 1 1 1 I.nL,I C U � I..I..I W L • ca (n n L _ U 'W^ U ~ Q 2- o CD O Of M W 00 00 rn Q Z U— 7 II -- Lu H Lu Lu w cn U w' -;T Z _j, QJ w Mr Q Ca L E w -� CU Q U 0 U) o �6 L • 0 - Ca 'W^ U ~ Q UN o oo 7 � ET a t Q N 0 A-9 Project Number Sheet Number OF Sheet Contents Project Title Drawn By Checked By Date Date Reproduction or re-use of these drawings without the written permission of the Design Team is prohibited. ADVANCED DRAFTING SERVICES 1011 MELLEN STREET CENTRALIA, WA. 98531 360 - 736 - 4751 PLANNING - DESIGN - DOCUMENTATION A Triplex for: Cynthia Schmier 204 SE Railroad Ave. Yelm, Wa.