2020.0025 2126-2 Heating_System_Sizing_Worksheet - Heating Sizing(07/01/13) Simple Heating System Size: Washington State This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This calculator will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please fill out all of the green drop-downs and boxes that are applicable to your project. As you make selections in the drop-downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop-down options, please call the WSU Energy Extension Program at (360) 956-2042 for assistance. Project Information Contact Information 2126-2 LEVEL DESIGN LLC 253 284-3170 Heating System Type: To see detailed instructions for each section, place your cursor on the word "Instructions". Design Temperature Instructions Design Temperature Difference (∆T)53.0 ∆T = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft)(2,126) Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft)8.5 (18,071) Glazing and Doors U-Factor X Area =UA Instructions 0.280 (298)83.44 Skylights U-Factor X Area =UA Instructions 0.50 (0)--- Insulation Attic U-Factor X Area =UA Instructions 0.026 (1,322)34.37 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions No selection --- Above Grade Walls (see Figure 1)U-Factor X Area UA Instructions 0.056 (2,856)159.94 Floors U-Factor X Area UA Instructions 0.025 (1,322)33.05 Below Grade Walls (see Figure 1)U-Factor X Area UA Instructions No selection --- Slab Below Grade (see Figure 1)F-Factor X Length UA Instructions No selection --- Slab on Grade (see Figure 1)F-Factor X Length UA Instructions No selection --- Location of Ducts Instructions Duct Leakage Coefficient (1.10) Sum of UA 310.80 Envelope Heat Load (16,472)Btu / Hour Sum of UA X ∆T Air Leakage Heat Load (10,344)Btu / Hour Volume X 0.6 X ∆T X .018 Building Design Heat Load (26,816)Btu / Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load (29,498)Btu / Hour Ducts in unconditioned space: Sum of Building Heat Loss X 1.10 Ducts in conditioned space: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output (41,297)Btu / Hour Building and Duct Heat Loss X 1.40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 for Heat Pump