Loading...
2021.0011.SF0004 204 SE Railroad Ave.Yelm DUPLEX Permit Setm d U m 3 N� N� 0 rl- SHEET INDEX A-1 SITE PLAN - INDEX OF DRAWINGS A-2 FOUNDATION PLAN A-2.1 FOUNDATION DETAILS A-3 FIRST FLOOR PLAN - ELEVATIONS A-4 SECOND FLOOR PLAN - ROOF PLAN - SHEAR WALL SCHEDULE A-5 FLOOR FRAMING PLAN - FRAMING DETAILS A-6 ROOF FRAMING PLAN - STRUCTURAL NOTES A-1 'A' SECTION - 'B' SECTION A-& WALL TYPES AND FLOOR ASSEMBLIES A-9 GENERAL NOTES - NAILING SCHEDULE - WINDOW INSTALLATION DETAIL - WATER HEATER SUPPORT DETAIL ti U "' M ti CD co Aco T,4 UL AT I ®N5: // L - � SITE AREA 1200 SOFT. +/- 100% 1-1110, BUILDING AREA 2418 SQFT. +/- 20% PLANTING // I � m DRIVEWAY AREA 1010 SOFT. +/- .08% I .� wc/) n ca C // i N // I o / I // I / I z // by J� RIVEWAY / ° I U) TRANCE I � U I " Lu I I co ILu co DRIVEWAY o, I 0 Lu Q z z Q < meg, I 2i 8, I Q z w I O U Lu Z Lu \\ 110, w W CID \ /p U Lo \ / / / z w J Z Q �w co / / z > PLANTING \ \ / Q Q COV. PORC \ \ ° 10, 0- Q o � \ \ \ \\ � UNIT 2 \ // REAR YARD / 101, \\\ OCG \ \ // \ Cov"Irr/ CN Ca a \\ 100, S \ � A OA �� \ \ / / ���ti oQ�g' 0 lil Q¢ SITO PLAN SCALE: 1/8" = 1'-0" LLJ O \ 3 �y 0 0 U) U N � U � SHEET INDEX A-1 SITE PLAN - INDEX OF DRAWINGS A-2 FOUNDATION PLAN A-2.1 FOUNDATION DETAILS A-3 FIRST FLOOR PLAN - ELEVATIONS A-4 SECOND FLOOR PLAN - ROOF PLAN - SHEAR WALL SCHEDULE A-5 FLOOR FRAMING PLAN - FRAMING DETAILS A-6 ROOF FRAMING PLAN - STRUCTURAL NOTES A-1 'A' SECTION - 'B' SECTION A-& WALL TYPES AND FLOOR ASSEMBLIES A-9 GENERAL NOTES - NAILING SCHEDULE - WINDOW INSTALLATION DETAIL - WATER HEATER SUPPORT DETAIL ti U "' M ti CD co Aco T,4 UL AT I ®N5: // L - � SITE AREA 1200 SOFT. +/- 100% 1-1110, BUILDING AREA 2418 SQFT. +/- 20% PLANTING // I � m DRIVEWAY AREA 1010 SOFT. +/- .08% I .� wc/) n ca C // i N // I o / I // I / I z // by J� RIVEWAY / ° I U) TRANCE I � U I " Lu I I co ILu co DRIVEWAY o, I 0 Lu Q z z Q < meg, I 2i 8, I Q z w I O U Lu Z Lu \\ 110, w W CID \ /p U Lo \ / / / z w J Z Q �w co / / z > PLANTING \ \ / Q Q COV. PORC \ \ ° 10, 0- Q o � \ \ \ \\ � UNIT 2 \ // REAR YARD / 101, \\\ OCG \ \ // \ Cov"Irr/ CN Ca a \\ 100, S \ � A OA �� \ \ / / ���ti oQ�g' 0 lil Q¢ SITO PLAN SCALE: 1/8" = 1'-0" LLJ O \ 3 �y 0 0 U) ca \ � U) H N N a 0 � Q 0 N O O N H N � U � N O O N H A-2 Project Number Sheet Number OF Sheet Contents Project Title A Duplex for: Cynthia Schmier 204 SE Railroad Ave. Yelm, Wa. Drawn By Checked By Date Date Structural Engineer Precise Engineering Inc. 1011 Mellen Street Centralia, Wa. 98531 Ph. 360-736-1137 Reproduction or re-use of these drawings without the written permission of the Design Team is prohibited.TTARKN E NHAH.DDLORAH N E F SSIO OPR N EE NAL G IREADVANCED DRAFTING SERVICES 1011 MELLEN STREET CENTRALIA, WA. 98531 360 - 736 - 4751 PLANNING - DESIGN - DOCUMENTATION T:\20160127 - Drawings 2\Multi-Family\Cynthia Schmier\204 SE Railroad Ave. Yelm\204 SE Railroad Ave.Yelm DUPLEX Permit Set.dwg, 12/14/2020 8:12:53 AM, _AutoCAD PDF (General Documentation).pc3 A-2.1 Project Number Sheet Number OF Sheet Contents Project Title A Duplex for: Cynthia Schmier 204 SE Railroad Ave. Yelm, Wa. Drawn By Checked By Date Date Structural Engineer Precise Engineering Inc. 1011 Mellen Street Centralia, Wa. 98531 Ph. 360-736-1137 Reproduction or re-use of these drawings without the written permission of the Design Team is prohibited.TTARKN E NHAH.DDLORAH N E F SSIO OPR N EE NAL G IREADVANCED DRAFTING SERVICES 1011 MELLEN STREET CENTRALIA, WA. 98531 360 - 736 - 4751 PLANNING - DESIGN - DOCUMENTATION T:\20160127 - Drawings 2\Multi-Family\Cynthia Schmier\204 SE Railroad Ave. Yelm\204 SE Railroad Ave.Yelm DUPLEX Permit Set.dwg, 12/14/2020 8:12:58 AM, _AutoCAD PDF (General Documentation).pc3 A-3 Project Number Sheet Number OF Sheet Contents Project Title A Duplex for: Cynthia Schmier 204 SE Railroad Ave. Yelm, Wa. Drawn By Checked By Date Date Structural Engineer Precise Engineering Inc. 1011 Mellen Street Centralia, Wa. 98531 Ph. 360-736-1137 Reproduction or re-use of these drawings without the written permission of the Design Team is prohibited.TTARKN E NHAH.DDLORAH N E F SSIO OPR N EE NAL G IREADVANCED DRAFTING SERVICES 1011 MELLEN STREET CENTRALIA, WA. 98531 360 - 736 - 4751 PLANNING - DESIGN - DOCUMENTATION T:\20160127 - Drawings 2\Multi-Family\Cynthia Schmier\204 SE Railroad Ave. Yelm\204 SE Railroad Ave.Yelm DUPLEX Permit Set.dwg, 12/14/2020 8:13:03 AM, _AutoCAD PDF (General Documentation).pc3 CCF VENT I L AT I CN'VENTING AREA 5HALL BE Y3OmTH. PER IRG 12032 ROOF AREA (UPPER) 2184 SQ. FT. ROOF AREA (LOUIER) 521 SQ. FT. 2184 / 300 = 128 SQ. FT. 1048 SQ. INCHES REQUIRED 521 / 300 = 1.1 SQ. FT. 244.8 SQ. INCHES REQUIRED 50% VENT REQ. AT RIDGE 524 SQ, INCHES 50% VENT REQ. AT RIDGE 122A SQ. INCHES 50% VENT REQ. AT SAVE 524 SQ. INCHES 50% VENT REQ. AT SAVE 122.4 SQ. INCHES T'YPIC'AL SHEAR WALL NOTES Use 5/8" dia. by 10" Anchor Bolts (AB's) with single plates and 5/8" dia. by 12" AB's with double and 3x plates spaced as shown on the drawings. AB's shall have 7" of embedment into footing, shall be centered in the stud wall, and shall project through the bottom plate of the wall and have a 3x3x1/4 plate washer. There shall be a minimum of two bolts per piece of sill located not more than 12 inches or less than 4 inches end of each piece. Anchor bolts to be galvanized per the below requirement (Fasteners in contact with pressure treated lumber). At existing foundation use 5/8" diameter Simpson Titen HG bolts with minimum of 4" embedment into the existing concrete. All wall sheathing shall be 1/2" CDX plywood, 5/8" T1-11 siding, or 7/16" OSB with exterior exposure glue and span rated "SR 24/0" or better. All free sheathing edges shall be blocked with 2x4 or 2x6 flat blocking except where noted on the drawings or below. All nails shall be 8d or IOd common (8d common nails must be 0.131 inch diameter, Senco KC27 Nails are equivalent. If 1 dd common nails are called for the diameter must be 0.148 inches, Senco MD23 Nails are equivalent). Nail size and spacing at all sheathing edges shall be as required below or as in the drawings. Nail spacings shall be 12" o.c. for all field nailing except as noted. Hold downs are Simpson "Strong Tie" and shall be installed per the manufacture's recommendation. Equivalent hold downs by United Steel Products Company "Kant -Sag" that have ICBG approval can be substituted in place of Simpson hold downs. All floor systems must be blocked solid below member that the hold down is attached to. This block should be equal to or larger than the member the hold down is attached to and be placed as a "squash block". SHEAR WALL SCHEDULE Al sheathing nailed with 8d's at 6" on center all edges. 02 sheathing nailed with 8d's at 3" on center all edges. HOLD DOWN SCHEDULE It is the responsibility of the contractor to locate hold down anchor bolt to accommodate all structural framing. Anchor bolt to be located nearest the corner or opening at the end of the shear wall. All foundation vents to be a minimum of 12" off centerline of the anchor bolt on either side. Holdown stud to be coordinated with shear wall panel edge framing requirements. Larger stud size controls * For holdown anchor bolt embedment greater that foundation depth, thicken footing for 2'-0" either side of holdown anchor bolt to a depth that provides for 3" clear below the bottom of the anchor bolt. Provide (2) additional #4 x Y -O" pieces of longitudinal rebar at this location. ® HD U4 attaches to concrete foundation with a Simpson SSTB 20. HDU4 attaches to double 2x studs or 4x or 6x stud with (10) Simpson SDS 1/4 X 3 Wood Screws in wall above. All double and triple studs shall glued and nailed together with l Od's at 3" o.c. for each layer. OB HD U5 All 4x studs are to be #2 DF and all 6x studs are to be 91 DF when used for hold downs and shear walls. FASTENERS IN CONTACT WITH PRESSURE TREATED LUMBER All fasteners including nuts and washers in contract with pressure treated lumber shall be hot -dipped zinc coated galvanized steel, stainless steel, silicon bronze or copper. Fasteners other than nails, timber rivets, wood screws and lag screws shall be permitted to be of mechanically deposited zinc coated steel in accordance with ASTM B 695, Class 55 minimum. Fasteners exposed to weather must meet the requirements of the pressure treating manufacture's minimum. IN ADDITON, the contractor shall coordinate connector/fastener coating requirements with recommendations from connector/fastener manufacturer and type of pressure treating chemical and retention being used. See Section 2304.10.5 of the 2015 IBC for additional information. ALL WALL STUDS AND ROOF TRUSS TOP CHORDS AND SECONDARY FRAMING LUMBER SHALL BE DOUG -FIR #2 OR BETTER. NOTE: MST STRAPS attaches to (2) 2x or 4x studs in wall above and below unless noted otherwise. Nail all holes with 16d sinkers. Double studs may be use as a substitute for 3x nominal framing call out below. Studs MUST be glued and nailed together with (2) lines of 10d's at 3" on center staggered. Horizontal blocking for shear walls nailed with 8d's shall be minimum of 2x flat and shear walls nailed with l dd's shall be minimum of 3x flat. ROOF PLAN SCALE: 1/8" = 1'-0" FOR APA PORTAL FRAME attaches to concrete foundation with a Simpson SSTB 24. HDU5 attaches to double 2x studs or 4x or 6x stud with (14) Simpson SDS 1/4 X 3 Wood Screws in wall above. ol 26'-10" 26'-10" 6'-5" SECOND FLOOR PLAN 0 co ti l�co o co M Lf') Q o bis V� O�ObbH � O�� eQ co ti l�co o co U5 0— 0 M W 00 u7 V) Q � V Z J LL Z Q W �/ U H W W H W U) o U z ti �I z _U' -;T I QJCo w r - M Q M Lf') Q (D W M -EZ 3,6: L, CU _0 � U � � c U W (D a) ca x C L _(_ U }+ 'W v^) U Q o Q �O UN � 0 U5 0— 0 M W 00 u7 V) Q � V Z J LL Z Q W �/ U H W W H W U) o U z ti �I z _U' -;T I QJCo w r - M Q Ca Q L E � U � L C//w/' - / CU C O O L •CU x C LL Q }+ 'W v^) d U Q o Q �O UN � 0 Za at z Q a A-5 Project Number Sheet Number OF Sheet Contents Project Title A Duplex for: Cynthia Schmier 204 SE Railroad Ave. Yelm, Wa. Drawn By Checked By Date Date Structural Engineer Precise Engineering Inc. 1011 Mellen Street Centralia, Wa. 98531 Ph. 360-736-1137 Reproduction or re-use of these drawings without the written permission of the Design Team is prohibited.TTARKN E NHAH.DDLORAH N E F SSIO OPR N EE NAL G IREADVANCED DRAFTING SERVICES 1011 MELLEN STREET CENTRALIA, WA. 98531 360 - 736 - 4751 PLANNING - DESIGN - DOCUMENTATION T:\20160127 - Drawings 2\Multi-Family\Cynthia Schmier\204 SE Railroad Ave. Yelm\204 SE Railroad Ave.Yelm DUPLEX Permit Set.dwg, 12/14/2020 8:13:08 AM, _AutoCAD PDF (General Documentation).pc3 General Notes: These structural notes supplement the drawings. Any discrepancy found among the drawings, these notes, and the site conditions shall be reported to the Engineer, who shall correct such discrepancy in writing. Any work done by the Contractor after discovery of such discrepancy shall be done at the Contractor's risk. The Contractor shall verify and coordinate the dimensions among all drawings prior to proceeding with any work or fabrication. The Contractor shall coordinate between the architectural drawings and the structural drawings. The architectural dimensions are taken to be correct when in conflict with the structural drawings. The Contractor is responsible for all bracing and shoring during construction. All construction shall conform to the applicable portions of the latest edition of the International Building Code except where noted Desi_gn Criteria: 1. Live Load = 40 PSF (Floors) = 60 PSF (Decks) = 25 PSF (Snow) 2. Dead Load = 15 PSF (Roof) = 12 PSF (Floor) = 10 PSF (Deck) = 10 PSF (Walls) = 150 PCF (Concrete) 3. Partition = 10 PSF (Floors) 4. Wind = 2015 IBC Exposure B @ 110 mph 5. Earthquake = 2015 IBC Site Class = D Design Cat. _ ❑ Use Group = I R = 6.5 Cd = 4 Wa = 3 6. Soil = 1500 PSF, Assumed bearing capacity = 38 PCF, Assumed Active Fluid Pressure = 350 PCF, Assumed Passive fluid Pressure = 0.45, Assumed Coefficient of Friction = 110 PCF, Assumed Soil Density Concrete Relnforcinp steel: 1. All concrete work shall be per the 2015 IBC Chapter 19. 2. All reinforcing shall be ASTM A615 Grade 60 except as shown on the plans. 3. Concrete shall be in accordance with ASTM 150. f = 2500 PSI @ 28 day slump = 4" maximum, 6% Air entrained. 4. Garage slab and exterior slabs to have minimum thickness of 4" with 6x6 W1.40.4 WWF with vapor barrier. This is at the owner's option to reduce slab cracking. Crack control joints the responsibility of the contractor Steel: 1. Anchor bolts shall be ASTM A307. Carpentry: 1. 2X structural framing shall be #2 Douglas Fir. 4x structural members shall be #2 Douglas Fir. 6X members shall be #1 Douglas Fir. 2. Provide solid blocking in floor system below all bearing walls and point loads. 3. 2X joists shall be kiln dried and stored in a dry area prior to installation. The moisture content of all wood shall be less than 15%. 4. Floorjoists shall be by Boise Cascade or other approved manufacturer. Joist to be installed and braced per manufacturer's requirements. 5. Roof trusses shall be by a pre -approved manufacturer and constructed according to the specifications of the Truss Plate Institute. Truss shop drawings must be stamped by a licensed engineer and be on site at the time of construction. Preliminary truss drawings must be reviewed prior to construction. It is the truss manufacturer's responsibility to inform the engineer of record of any changes from the preliminary truss lay -out. Girder trusses to have a minimum of bearing studs equal to number of plies of truss. All girder trusses shall have Simpson HGT tie down at either end to match number of plies. Truss manufactures are responsible for all bracing of the trusses including end wall bracing and all other bracing between the building and the trusses unless specifically shown otherwise on the drawings. Contractor to coordinate bracing with engineer of record as required. 6. Glue laminated beams shall be 24F -V8 for cantilevered or continuous beams and 24F -V4 for simple spans. (Fb = 2,400 PSI) (Fv = 190 PSI) (E - 1,800,000 PSI) (FcL = 650 PSI) 7. Continuous and cantilevered glue laminated beams shall not be cambered. All other glue laminated beams shall be cantilevered for L/480. See the framing plans for any exceptions. 8. All manufactured lumber shall be by Boise Cascade and have the following structural properties: Versa Lam (VL) (Fb = 2,800 PSI) (Fv = 280 PSI) (E = 2,000,000 PSI) (FcL = 750 PSI) 9. Sheathing at roof and floor shall be laid with face grain perpendicular to supports and end joints staggered 4'-0" on center. Provide 1/8" space at panel edges as required by panel manufacturers. Floor sheathing shall be nailed 6" o.c. edges and 12" field with 10d's and roof sheathing shall be nailed 6" o.c. edges and 12" o.c field with 10d's unless otherwise noted on the drawings. 10. Block and nail all horizontal panel edges at designated shear walls. 11. All beams to be supported by a minimum of a solid post that matches the width of the wall and the width of the beam unless noted otherwise. A 6x beam bearing in 2x6 wall will be a 6x6. Provide solid squash blocking to match in floor system and match post size in foundation. Contact Engineer of record for any deviations. 12. All fasteners in contact with pressure treated lumber will meet the below requirements. All fasteners including nuts and washers in contract with pressure treated lumber shall be hot -dipped zinc coated galvanized steel, stainless steel, silicon bronze or copper. Fasteners other than nails, timber rivets, wood screws and lag screws shall be permitted to be of mechanically deposited zinc coated steel in accordance with ASTM B 695, Class 55 minimum. Fasteners exposed to weather must meet the requirements of the pressure treating manufacture's minimum. IN ADDITION, the contractor shall coordinate connector/fastener coating requirements with recommendations from connectorlfastener manufacturer and type of pressure treating chemical and retention being used. See Section 2304.10.5 of the 2015 IBC for additional information. 13. All GW B to be installed per the IBC and Gypsum Association's publication for the Application and Finishing of Gypsum Board, GA -216 Hardware: All connection hardware shall be Simpson "Strong Tie". Connection hardware exposed to the weather or soil shall be treated as in steel above. CAUTION: PLACE TRUSSES PER MANUFACTURER'S RECOMMENDATIONS AND BRACE PER TRUSS COMPANY RECCOMENDATIONS. CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY BRACING AND SHORING REQUIRED FOR PLACING TRUSSES. NOTE THESE DRAWINGS DO NOT INCLUDE ANY TEMPORARY SHORING OR BRACING. PRECISE ENGINEERING RECCOMENDS ALL SHORING AND BRACING BE DESIGNED AND DETAILED BY A LISENCED ENGINEER. �Ie7 �i �� T�CeI:irel�l ��el�J �:i[�7_i�Sele7�l e7�yCe7i: f`y►�l e7��i� ��I� �Cel�t` ROOF FRAMING NOTES I. USE 1/2" CDX OR 1/16" OSB SPAN RATED 24/0 OR BETTER AND NAIL W/ 8d NAILS a 6" O.C. EDGES AND 9 12" O.C. IN THE FIELD. (UNLESS NOTED OTHERWISE) 2. ALL HEADERS TO BE 4x8 DF "2 UNLESS NOTED OTHERWISE 3. TOP PLATE SPLICES: NAIL SPLICES w/ (2) ROWS 10d NAILS a 2" O.G. FOR 24" EITHER SIDE OF SPLICE (24) MIN. 10d NAILS EACH SIDE OF SPLICE. 4. ALL ROOF OVER FRAMING PROVIDED BY TRUSS MANUFACTURE. COORDINATE w/ GENERAL CONTRACTOR SCALE: I"=1' -0" ROOF LINE BELOW SHEAR SEE PL, A35 CL I TYR. UN CDX OF PRE -EN e 24" O. SHEAR SEE PL, SHEAR WALL CALL -OUT SEE PLAN TRUSS SEE PLAN HANGER 2x6 LEDGER w/ (2) 5D525350 9 16" O.G. 2x6 a 16" O.C. H25 CLIP EA. 32" O.C. SLOT SHTG. 2x FLAT BLOCKING CONT. 11/2"x11 1/8" LSL O TRUSS TO WALL coNN. DBL. 2 2x6 ST O ROOF LINE BELOW -E G. TRUSS a 24" O.C. 'SON Hl CLIP 9 24" O.C. DENTED BLOCKING a 4" O.G. 5/4" FASCIA AR WALL CALL -OUT PLAN TRUSS TO WALL SCALE: 1"=1'-0" UPPER ROOF FRAMING PLAN fD m 0 r` o co 5 1/20 1/2 G.L.B. `n •• � y� O�ObbH � eP M 00 ) ^,� W aD N L M u7 N > � 5 1/20 1/2 G.L.B. �.. J 00 rn C Z O_ (n DBL. TRIM DBL. KING ID a) a� DBL. TRIM I I DBL. KING W r�/L/�� VJ L A U Q U 2i J Of 0 U L.L Z Lu U O 0 �/ U Z 0 I - LU FS �, � 0 � U) W ci � U w Oc 0 Z Z LU M Z J 0 o � o co M - ,II I I II S - 00 II ` - O � 7 I C m m i4 �' fL z O � I � G - ,II III DSC2 T� G.T. l u rtRU55E5 a 24.. OG - in D5C2 DSC2 10000T. I \ u u u G.T. -P-ANG. TRUS 24 SE$ m 11 II DSC2 -ENG P C. UPPER ROOF LINE UPPER ROOF LINE WALL LINE BELOW WALL LINE BELOW LOWER ROOF LINE LOWER ROOF LINE UPPER ROOF FRAMING PLAN fD m 0 M r` o co � J C^ o `n •• � y� O�ObbH � eP M 0 0 r` o co M L ui � � U_ M 00 ) ^,� W aD N L M u7 N > � 0 �.. J 00 rn C Z O_ (n W ID a) a� _ W r�/L/�� VJ L A U Q U 2i J Of 0 U 0 0 U_ 0 a a� 0 Q Q M 0 00 O N 0 N N a� v7 a� a X ii Z) 0 E a� W Q 0 LU v O N E a� U) O z ui � � U_ N ) i N M u7 N > � 0 �.. J 00 rn C6 Z O_ (n O = O x � C13 1z Z Z Q L LJ 2i J Of 0 U L.L Z Lu U O 0 �/ U Z 0 I - LU 0 � 0 � U) W ci � U w 0 Z Z LU M Z J 0 o � o co M U_ 0 a a� 0 Q Q M 0 00 O N 0 N N a� v7 a� a X ii Z) 0 E a� W Q 0 LU v O N E a� O z � � N ) i N N > � 0 U C6 L O = O x -CU C- C13 1z N �+ L LJ Li U O H o Q a U N 0 � Q 0 U_ 0 a a� 0 Q Q M 0 00 O N 0 N N a� v7 a� a X ii Z) 0 E a� W Q 0 LU v O N E a� A-7 Project Number Sheet Number OF Sheet Contents Project Title A Duplex for: Cynthia Schmier 204 SE Railroad Ave. Yelm, Wa. Drawn By Checked By Date Date Structural Engineer Precise Engineering Inc. 1011 Mellen Street Centralia, Wa. 98531 Ph. 360-736-1137 Reproduction or re-use of these drawings without the written permission of the Design Team is prohibited.TTARKN ENHAH.DDLORAH N E F SSIO OPR N EE NAL G IREADVANCED DRAFTING SERVICES 1011 MELLEN STREET CENTRALIA, WA. 98531 360 - 736 - 4751 PLANNING - DESIGN - DOCUMENTATION T:\20160127 - Drawings 2\Multi-Family\Cynthia Schmier\204 SE Railroad Ave. Yelm\204 SE Railroad Ave.Yelm DUPLEX Permit Set.dwg, 12/14/2020 8:13:13 AM, _AutoCAD PDF (General Documentation).pc3 A-8 Project Number Sheet Number OF Sheet Contents Project Title A Duplex for: Cynthia Schmier 204 SE Railroad Ave. Yelm, Wa. Drawn By Checked By Date Date Structural Engineer Precise Engineering Inc. 1011 Mellen Street Centralia, Wa. 98531 Ph. 360-736-1137 Reproduction or re-use of these drawings without the written permission of the Design Team is prohibited.TTARKN E NHAH.DDLORAH N E F SSIO OPR N EE NAL G IREADVANCED DRAFTING SERVICES 1011 MELLEN STREET CENTRALIA, WA. 98531 360 - 736 - 4751 PLANNING - DESIGN - DOCUMENTATION T:\20160127 - Drawings 2\Multi-Family\Cynthia Schmier\204 SE Railroad Ave. Yelm\204 SE Railroad Ave.Yelm DUPLEX Permit Set.dwg, 12/14/2020 8:13:18 AM, _AutoCAD PDF (General Documentation).pc3 A-9 Project Number Sheet Number OF Sheet Contents Project Title Drawn By Checked By Date Date Reproduction or re-use of these drawings without the written permission of the Design Team is prohibited. ADVANCED DRAFTING SERVICES 1011 MELLEN STREET CENTRALIA, WA. 98531 360 - 736 - 4751 PLANNING - DESIGN - DOCUMENTATION A Duplex for: Cynthia Schmier 204 SE Railroad Ave. Yelm, Wa. T:\20160127 - Drawings 2\Multi-Family\Cynthia Schmier\204 SE Railroad Ave. Yelm\204 SE Railroad Ave.Yelm DUPLEX Permit Set.dwg, 12/14/2020 8:13:24 AM, _AutoCAD PDF (General Documentation).pc3