2021.0019.FR0001 28-3176 - FIRE ALARM
FIRE ALARM/EMERGENCY COMMUNICATION SYSTEM – SECTION 28 3176 6820EVS Intelligent Fire Alarm Control Panel with Emergency Voice System The 6820EVS is an intelligent addressable Fire Alarm Control Panel combined with an Emergency Voice System (EVS) and are direct replacements for the 5820XL-EVS FACP. When the EVS features are enabled, they are integrated with the fire alarm and voice evacuation functions of the control panel. The emergency voice system operations include an onboard supervised microphone. All-call and non-active call buttons can quickly select all active or non-active output groups. The system also allows for emergency messages over fire. The 6820EVS FACP has one built-in signaling line circuit (SLC), which can support 159 SK detectors and 159 SK modules, or 127 SD protocol devices. Additional SLC loops can be added for a maximum of 1110 (SK) or 635 (SD) points per panel. The built-in digital alarm communicator/transmitter (DACT) is dual technology, IP and POTS. The POTS transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The IP communicator’s internet monitoring capability sends alarm signals over the Internet saving the monthly cost of two dedicated business telephone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line. Optional cellular reporting is available. The 6820EVS has six onboard Flexput® circuits that can be configured as notification outputs or auxiliary power. The 6820EVS also has a form-C trouble relay, and two programmable form-C relays, along with powerful features such as drift compensation, pre- trouble maintenance alert, a built-in sensor test to comply with NFPA 72 calibration testing requirements, and a calibration trouble alert. A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable. A designated panel is configured as the communicator for all panels in the link for convenient single-point communications. FEATURES AND BENEFITS • Single enclosure for both fire and emergency voice components • Ability to select EVS messages as priority over fire • 15 Recordable one-minute messages that can be mapped to eight EVS buttons • Capable of producing 520 Hz tones to meet NFPA 72 requirements • Support for up to 4 LOCs and 8 addressable amplifiers • Expandable SLC loops to 1110 (SK) or 635 (SD) point capacity • Six Flexput circuits for NAC outputs or auxiliary power • Selectable strobe synchronization for Amseco®, System Sensor, Wheelock®, and Gentex® devices • Built-in DACT with IP and optional cellular reporting • Built-in USB interface for quick and easy programming • JumpStart® auto programming reduces installation time • 999 software zones & 999 output groups for flexible design options • 23 preset notification cadence patterns (including ANSI® 3.41) • Allows up to 24 SBUS devices • Four programmable function keys • Two programmable relays and one fixed trouble relay • Compatible with SWIFT® wireless devices • Convenient field-upgradeable firmware • Network support for up to 17 sites • Network card allows copper network connection with a multi-mode or single- mode fiber connection • Real-time clock/calendar with automatic daylight savings control • History file with 1,000 event capacity The 6820EVS panel and accessories provide features to meet the requirements for Mass Notification Systems as described in UL 2572. 28-3176 2.02 Page 2 of 4 — 351606:D • 3/31/2020 USER INTERFACE LED INDICATORS • General Alarm (Red) • Supervisory (Yellow) • System Trouble (Yellow) • System Silenced (Yellow • System Power (Green) KEYPAD • 12-key numeric pad •Acknowledge • Alarm Silence •System Reset •Drill • F1-F4 Programmable Function Keys PROGRAMMING The 6820EVS system offers several options to simplify and expedite programming. JumpStart® auto programming minimizes programming required to start a new system. The built-in keypad, or the remote annunciators give on-site access to current system programming. System programming can also be accomplished using the Windows®-based Honeywell Fire Software Suite (HFSS). ORDERING INFORMATION 6820EVS: Addressable fire alarm control panel, red COMPATIBLE EVS EQUIPMENT EVS-50W: 50 Watt amplifier EVS-125W: 125 Watt amplifier EVS-100W: 50/100 Watt amplifier EVS-100WBU: External backup amplifier EVS-INT50W: 50 /Watt internal amplifier EVS-CE4: Provides 4 additional audio circuits EVS-RVM: Remote voice module EVS-SW24: 24 switch expander EVS-VCM: Network voice control module EVS-LOC: Local operator console COMPATIBLE SBUS DEVICES 6860: 4x40 LCD remote fire annunciator with four programmable buttons, red 5860: 4x20 LCD remote fire annunciator, gray 5860R: 4x20 LCD remote fire annunciator, red 6855: 4x20 LCD remote fire annunciator, red 5865-3: LED annunciators- display up to 30 LEDs (15 red/15 yellow) 5865-4: LED annunciators- display up to 30 LEDs (15 red/15 yellow). Key switches for silence and reset, and a system trouble LED 5880: LED I/O module with 40 programmable LED outputs and eight supervised dry contact inputs 5883: Relay interface. Provides 10 Form C relays 5824: Serial/Parallel printer interface module for printer connection SK COMPATIBLE ADDRESSABLE DEVICES Note: SKand SD devices cannot be mixed in the same fire alarm system. SK-ACCLIMATE: Multi criteria photoelectric smoke detector with thermal 135°F fixed temperature SK-BEAM: Reflected beam smoke detector without test feature SK-BEAM-T: Reflected beam smoke detector with test feature OSI-RI-SK: Reflected beam smoke detector, SK protocol SK-CONTROL: Supervised control module SK-CONTROL-6: Six circuit supervised control module SK-DUCT: Photoelectric duct smoke detector with extended air speed range SK-FIRE-CO: Four criteria fire and carbon monoxide detector SK-FIRE-CO-W: Four criteria fire and carbon monoxide detector, white SK-HEAT: Fixed thermal detector (135°F) SK-HEAT-W: Fixed thermal detector (135°F), white SK-HEAT-ROR: Fixed rate of rise detector SK-HEAT-HT: Fixed high temperature heat detector (190°F) SK-HEAT-HT-W: Fixed high temperature heat detector (190°F), white SK-HEAT-ROR-W: Fixed rate of rise detector, white SK-ISO: Fault isolator module SK-MINIMON: Mini monitor module SK-MONITOR: Monitor module SK-MONITOR-2: Dual input monitor module SK-MON-10: 10- input monitor module SK-PHOTO: Photoelectric smoke detector SK-PHOTO-W: Photoelectric smoke detector, white SK-PHOTO-R: Photoelectric detector with remote test capability SK-PHOTO-R-W: Photoelectric det. with remote test capability, white SK-PHOTO-T: Photoelectric smoke detector with fixed heat (135°F) SK-PHOTO-T-W: Photoelectric smoke detector with fixed thermal heat (135°F), white SK-PTIR-W: Multi criteria photoelectric smoke detector with thermal 135°F fixed temperature, white SK-PULL-SA Addressable single action pull station SK-PULL-DA: Addressable dual action pull station SK-RELAY: Addressable relay module SK-RELAY-6: Addressable Six relay control module SK-RELAYMON-2: Addressable Dual relay/monitor module SK-ZONE: Addressable zone interface module SK-ZONE-6: Six zone interface module SK BASES B210LP: 6" mounting base B501: 4" Flangeless mounting base B200S: Intelligent sounder base Page 3 of 4 — 351606:D • 3/31/2020 B200S-LF: Low-frequency intelligent sounder base B224RB: Relay base B224BI: Isolator base SD COMPATIBLE ADDRESSABLE DEVICES Note: SK and SD devices cannot be mixed in the same fire alarm system. SD505-6AB: Addressable 6" base SD505-6IB: Addressable 6" short circuit isolator base SD505-6RB: Addressable 6" relay base SD505-6SB: Addressable 6" sounder base SD500-AIM: Addressable input module (switch input) SD500-ANM: Addressable notification module SD500-ARM: Addressable relay module SD505-DTS-K: Remote test switch/LED indicator for the SD505-DUCTR SD505-DUCT: Addressable Duct Smoke Detector SD505-DUCTR: Addressable Duct Detector housing with relay base SD505-HEAT: Absolute temperature heat detector. Trip point range from 135°F–150°F (0°C–37°C) SD500-LIM: Addressable Line isolator module SD500-MIM: Addressable Mini input monitor module (switch input) SD505-PHOTO: Photoelectric smoke detector SD500-PS/-PSDA: Addressable Single or dual action pull station SD500-SDM: Addressable smoke detector module SWIFT WIRELESS DEVICES Note: SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices. WSK-WGI: Wireless gateway WSK-PHOTO: Wireless photoelectric smoke detector with B501W base WSK-PHOTO-T: Wireless photoelectric smoke detector with fixed thermal detection (135°F) and B501W base W-SYNC: Wireless sync module WSK-HEAT: Wireless, fixed heat detector (135°F) with B501W base WSK-HEAT-ROR: Wireless rate-of-rise heat detector and B501W base WSK-MONITOR: Wireless monitor module WSK-RELAY: Wireless relay module WSK-PULL-DA: Wireless pull station WAV-CRL, WAV-CWL: Wireless AV bases W-USB: Wireless USB radio/antenna dongle that plugs into the USB port of a PC running SWIFT Tools SWIFT Tools: Programming and diagnostic utility for the wireless gateway and devices. Available for download from www.farenhyt.com SYSTEM EXPANDERS 6815: SLC Expander for IDP or SK devices 5815XL: SLC expander for SD devices RPS-1000: 6A power supply with 6 Flexput circuits & 2 Form C relays 5496: 6 amp NAC power expander with 4 power-limited output ckts OPTIONAL COMMUNICATORS CELL-CAB-SK: Cellular communicator, metal enclosure w/lock & key CELL-MOD: Cellular communicator, plastic enclosure IPGSM-4G: Dual path fire alarm communicator, cellular and/or IP (primary or backup, selectable) SK-IP -2: Remote reporting via the Internet. Requires a VisorALARM® receiver at the central station MISCELLANEOUS ACCESSORIES SK-NIC: Network Interface Card. Provides a common communications link for the IFP-300 SK-NIC-KIT: Installation Accessory Kit SK-FML: Fiber-Optic Multi Mode, transmitter and receiver SK-FSL: Fiber-Optic Single Mode RBB: Remote battery box accessory cabinet SK-SCK: Seismic compliance kit used to fasten batteries to the fire panel SOFTWARE SOLUTIONS SKST: Silent Knight Selection Tool provides the installer or design architect with a Windows®-based software system configuration tool to create a detailed bill of material (BOM) and battery calculations HFSS: Honeywell Fire Software Suite provides remote and local panel programming, detector status, event history and additional data. Databases can be uploaded/downloaded via the panel’s USB port using a flash drive. Requires a PC running Microsoft® Windows®. 6820EVS TECHNICAL SPECIFICATIONS 351606 | D | 03/20 ©2020 Honeywell International Inc. Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.silentknight.com Flexput®, Honeywell®, JumpStart®, Silent Knight®, SWIFT®, and System Sensor® are registered trademarks of Honeywell International Inc. Amseco® is a registered trademark of Potter Electric Signal Company, LLC. Gentex® is a registered trademark of Gentex Corporation. Hochiki® is a registered trademark of Hochiki Corporation. Wheelock® is a trademark of Cooper Technologies Company. ANSI® is a registered trademark of the American National Standards Institute, Inc. VisorALARM® is a registered trademark of the Teldat Corporation. Microsoft® and Windows® are registered trademarks of Microsoft Corporation. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Country of origin: USA SYSTEM CAPACITY Intelligent Signaling Line Circuits: 1 (expandable) Addressable device capacity: 1110 (SK) or 635 (SD) Programmable software zones: 999 Output circuits: 6 (expandable) SBUS devices: 24 (16 annunciators, 8 LED modules) LOC units: 4 Addressable amplifiers (total watts): 8 (1000) ELECTRICAL AC Power: 120VAC, 60Hz, 2.7A Standby Current: 190 mA Alarm Current: 250 mA Flexput Circuits: Terminal block provides connections for (six Class B or three Class A) NACs or auxiliary power. Power-limited, supervised circuitry. Maximum current per circuit: 3 A. Cannot exceed 6A total for all circuits. End-of-line resistor: 4.7k ohm, ½ watt for Class B NAC Communication Loop: Supervised and power-limited, Class A or Class B, 32VDC, 150mA Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.5 A @ 27.4 VDC (resistive), Form C Battery: Cabinet holds maximum of two 18 AH batteries Battery Charger Capacity: 7-35 AH PHYSICAL Dimensions: 21.6” W x 28.1” H x 5.1” D (54.9cm W x 71.4cm H x 13.0cm D) Weight: 50 lbs. (22.7 kg.) Color: Red TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 – 49°C (32– 120°F) and at a relative humidity 93% ± 2% RH (non- condensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27°C/60 – 80°F. NFPA STANDARDS The 6820 complies with the following NFPA 72 Fire Alarms Systems requirements: NFPA 13, NFPA 15, NFPA 16, NFPA 70, NFPA 72 Central station; remote Signaling; Local Protective Signaling Systems; Auxiliary Protected Premises Unit; Water Deluge releasing service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non-coded) signaling services AGENCY LISTINGS AND APPROVALS The listings and approvals below apply to the basic 6820 control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S2766 CSFM: 7165-0559:0500 FDNY: COA# 6249 FM: Approved FEATURES & BENEFITS •80-character backlit LCD display (4 lines with 20 characters per line) •Tactile / audible feedback when a key is pressed on the annunciator •Uses the RS-485 SBUS to interface with the panel •Support for simultaneous use of multiple 5860s •Easily view current status by alarms, supervisories, or troubles •Five Status LEDs •Available in red or light gray color •Accommodates wiring lengths up to 6000 ft. from the control panel for added design and install flexibility •Accepts user codes or fire fighter’s key •Larger keypad buttons makes it easier to maneuver for system reset and silencing 5860 Remote Annunciator The 5860 remote annunciator, can be used to operate and program Honeywell Silent Knight fire alarm control panels (FACPs) from anywhere within the system. The 5860 features include an 80-character backlit LCD providing easy-to understand system messages. The annunciator is ergonomically designed with over-sized buttons for the most frequently used features, like Reset and Silence. In addition to status messages displayed on the LCD, there are five LEDs for alarm, supervisory, trouble, silence, and AC power status. The 5860 annunciator is available in gray to match virtually any decor and red for applications where the annunciator must stand out. The annunciator enclosure can be surface or flush mounted. A trim ring kit is available for surface mounting. COMPATIBILITY The 5860 is compatible with the following Honeywell Silent Knight FACPs: 6820: Addressable fire alarm control panel with up to 1,110 addressable points 6820EVS: Addressable fire alarm control panel with an emergency communication systems and up to 1,110 addressable points 6808: Addressable fire alarm control panel with up to 198 addressable points 6700: Addressable fire alarm control panel with up to 100 addressable points 5820XL: Addressable fire alarm control panel 5820XL-EVS: Addressable fire alarm control panel with an emergency communication systems 5808: Addressable fire alarm control panel 5700: Addressable fire alarm control panel 5860 / 5860R 28-3176 2.04 For a complete listing of all compliance approvals and certifications, please visit www.silentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Silent Knight® and Honeywell® are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 800-446-6444. 5860 Technical Specifications PHYSICAL Dimensions: 9.1”W x 7.4”H x 1.5”D (23.1W x 18.8H x 3.8D cm) Shipping Weight: 2.8 lbs (1.3 kg) Color: 5860R: Red; 5860: Gray ENVIRONMENTAL Operating Temperature: 32°F to 120°F (0°C to 49°C) Humidity: 10% - 93% non-condensing) ELECTRICAL Operating Voltage: 24VDC Standby Current: 20mA Alarm Current: 25mA ORDERING INFORMATION 5860: Remote Annunciator, four line (4x20) LCD annunciator with 20 characters per line. Gray 5860R: Remote Annunciator, four line (4x20) LCD annunciator with 20 characters per line. Red ACCESSORIES 5860TR: Red Trim Ring for surface mounting 5860TG: Gray Trim Ring for surface mounting AGENCY LISTINGS AND APPROVALS UL listed CSFM approved Meets NFPA 72 requirements FM approved MEA approved Doc 350224 | Rev J | 12/17 © 2017 Honeywell International Inc. For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 5860 Features annunciation, providing 40 programmable LED outputs and eight supervised dry contact inputs. You can use up to eight 5880 modules on one EVS-LOC control panel for maximum fl exibility. Its compact size enables it to be mounted inside the EVS-LOC, or in an accessory cabinet. About Silent Knight's emergency voice system: The 6820EVS is a fi re and emergency voice communication system conveniently integrated and housed in one panel, and meets the requirements for mass notifi cation as described in UL 2572. COMPATIBILITY 6820EVS: Addressable fi re alarm control panel with an emergency mass notifi cation system, up to 1,110 addressable points, a large 160 character 4 x 40 display, and four programmable buttons that can be programmed for routine or complex tasks Note: It can also be used with existing 5820XL-EVS installations FEATURES & BENEFITS • Provides additional communications and control options that are also available in the 6820EVS primary panel • Useful for extending system access to additional areas of a building or mass notifi cation network • Makes access to the communication system easier when immediate and timely communications are essential • Up to four EVS-LOCs can be added to a compatible emergency voice system for a total of fi ve command units. This provides additional control options which are critical during emergency events when the 6820EVS panel is not within easy reach. • For added fl exibility, it can also accept programmable trigger inputs from external source, such as a Monaco® system, to either the RVM or Silent Knight's 5880. Up to eight inputs are available on the 5880 module. • Up to 32 mappable speaker circuits can be connected on the EVS-LOC using a combination of the EVS-50W, EVS-100W or EVS-125W amplifi ers. This is useful for extended reach during times when urgent emergency communication is required. Honeywell Silent Knight EVS-LOC Local Operator Console The EVS-LOC local operator console is a powerful addition to any emergency voice system for mass notifi cation purposes. The console is a combination supervised remote microphone and annunciator which is compatible with the EVS-Series Emergency Voice System and meets UL requirements for a local operator console (LOC). The EVS-LOC provides an interface to the 6820EVS Emergency Voice System. It has a supervised on-board microphone for live communications and its annunciator is capable of performing complete operation of the fi re alarm system, including silencing and resetting. It has a large 4x40 LCD backlit screen with up to 160 available characters, providing ample space for messaging. The EVS- LOC also has four programmable buttons which can be used to minimize time spent executing complex or routine tasks. The console's emergency communication system operations includes an on-board supervised microphone, and all call and non-active call buttons that can quickly select all active or all non-active output groups. The system also lets you select an EVS message as a priority over fi re. The EVS-CE4 is a useful addition to an EVS-LOC application. It adds four audio circuits to the EVS-50W, EVS-100W or EVS- 125W, mappable to 32 buttons controlling selected output groups. It is very useful for extended coverage and requires no additional space as it mounts inside the amplifi er cabinet. The 5880 LED / IO module can also be used with an EVS-LOC application. The module provides an effective means to customize your remote EVS-LOC • The optional VIP-TR trim ring is useful for creating a visual appealing interface between the panel and mounting wall 28-3176 2.05 For a complete listing of all compliance approvals and certifications, please visit www.silentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Silent Knight® and Honeywell® are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 800-446-6444. EVS-LOC Technical Specifications SPECIFICATIONS PHYSICAL Overall Dimensions: 20”W x 26.5”H x 5.05”D (50.75 W x 67.3 H x 12.8D cm) Color: Red ENVIRONMENTAL Operating Temperature: 32ºF – 120ºF (0ºC – 49ºC) Humidity: 10% – 93% non-condensing ELECTRICAL Standby Current: 100mA (6860 + RVM + SW-24) Alarm Current: 150mA (6860 + RVM + SW-24) Voice Integration Wiring: Six conductor Two voice bus Four SBUS ORDERING INFORMATION EVS-LOC: Local Operators Console ACCESSORIES EVS-SW24: 24 switch expander VIP-TR: panel trim ring for flush mounting 5880: LED/IO module EVS-CE4: 4 speaker circuit expander AGENCY LISTINGS AND APPROVALS UL 864 and UL 2572 Meets the requirements for NFPA 72 Local Protective Signaling Systems & Emergency Communication Systems CSFM approved 7165-0559:0500 FDNY COA (pending) INSTALLATION The EVS-LOC can be surface or flush mounted. Doc 351631 | Rev A | 10/17 © 2017 Honeywell International Inc. For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 EMERGENCY VOICE SYSTEM EXAMPLE FEATURES & BENEFITS •UL Listed for 6 amps of notification power •Power supply’s advanced switch mode design reduces damaging heat and manages power up to 50% more efficiently than other systems •24 VDC filtered output voltage • Built-in synchronization for appliances from Gentex, AMSECO, System Sensor, and Wheelock • Four power-limited notification outputs; 2 Class A or 4 Class B, or 1 Class A and 2 Class B •NACs are programmable as notification appliance circuits, or as auxiliary power to be used as constant, resettable, or door holder power •3 amps per output circuit •Ground fault detector •CSFM approved •Communicates to the FACP via 4-wire SBUS (wire runs up to 6000 ft) •AC loss delay option shuts off power to non-essential high current accessories like magnetic door holders •ME A approved •Lightweight design adds to ease of installation and reduces shipping costs •ANSI Cadence pattern output capability built-in •UL 864,1481 & 1971 listed •OSHPD (CA) OSP-0065-10 (see accessories) 5496 Intelligent Power Module The 5496 intelligent power module is the most cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor®,Gentex®, AMSECO, and Wheelock®. The 5496’s advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. The 5496 is a 6 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery for use with the Honeywell Silent Knight series fire alarm control panels (FACPs). The 5496 is the cost-effective solution for powering notification appliances required by the Americans with Disabilities Act (ADA). The 5496 has built-in ANSI cadence pattern. The output circuits can be programmed as notification appliance circuits, or as auxiliary power (configurable for constant, resettable, or door holder power). Compatibility The 5496 is compatible with the following Honeywell Silent Knight FACPs: • 6820 / 6820EVS • 5820XL / 5820XL-EVS • 6808 • 670 0 • 5808 • 570 0 5496 28-3176 2.07 For a complete listing of all compliance approvals and certifications, please visit www.silentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. System Sensor® and Honeywell® are registered trademarks of Honeywell International, Inc This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 800-446-6444 5496 Technical Specifications PHYSICAL Overall Dimensions: 16" H x 12.25" W x 3" D (40.6 x 30.9 x 7.6 cm) Shipping Weight: 8.7lbs ENVIRONMENTAL Operating Temperature: 32°F to 120°F (0°C to 49°C) Humidity: 10 to 93% relative humidity (non- condensing) ELECTRICAL: AC Input: 120VAC at 2.7A Output: 24VDC at 6A Standby & Alarm Current: 10mA Notification/Aux. Power Circuits: 4 Output Configuration: 2 Class A (Style Z) 4 Class B (Style Y) 1 Class A & 2 Class B Amps Per Output Circuit: 3.0 (6.0 amps total) Notification Circuit Output: 20.4 – 27.3VDC @ 3.0A each End-of-Line Resistance: 4.7k W EOL resistor required on each Class B circuit Battery Charging Capacity: 7.0 – 35.0AH ORDERING INFORMATION 5496: Intelligent Power Module ACCESSORIES RBB: Remote Battery Box Accessory Cabinet. 16” W x 10” H x 6” D (406 mm W x 254 mm H x 152 mm D) SK-SCK: Seismic Compliance Kit AGENCY LISTINGS AND APPROVALS • CSFM approved • NF PA 72 • UL listed • FM approved • City of NY: 429-90-E Vol XIV Doc 350387| Rev F| 11/17 © 2017 Honeywell International Inc. For more information Learn more about Silent Knight's Product and other products available by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 www.silentknight.com FEATURES & BENEFITS •Integrates directly with Silent Knight Series 6000 panels. Installation is easy as there is no need for special programming or a separate dialer capture module •Battery backup provided by the fire alarm control panel for enhance efficiencies and cost savings • Communicators provide dual path cellular and IP reporting capability when combined with 6000 series panels • UL 864 and NFPA 72 code compliant for sole, primary, or backup communications •Accounts can be easily managed through on-line management tools •Remote mount up to 6000 feet to ensure best reception • Includes Quality of Service (QOS) diagnostics via AlarmNet which conveys vital communicator information, including when messages are received, signal strength, and message path used • Programmable supervision time from 1 to 60 minutes • Provides full data reporting using Contact ID format EVS-50W Intelligent 50 Watt Amplifier The EVS-50W is an intelligent 50 watt amplifier for use with the 5820XL- EVS or 6820EVS. The EVS-50W is used to amplify the audio message for distribution throughout the facility. Since it is designed as a self-contained distributed amplifier it can be conveniently located near the area of protection to reduce wiring demands. Each EVS-50W is capable of producing 50-watts of audio power. Up to four EVS-50W’s can be used on the voice evacuation system. The EVS-50W has its own power supply with battery backup and four speaker circuits which can be expanded to eight speaker circuits with the optional EVS-CE4. The EVS-50W is fully supervised by the main panel for trouble conditions. INSTALLATION The EVS-50W can be surface or flush mounted. COMPATIBILITY The EVS-50W is compatible with the following Honeywell Silent Knight Series FACPs: • 6820EVS: Addressable fire alarm control panel with an emergency voice system, up to 1,110 addressable points, and four programmable buttons that can be programmed for routine or complex tasks • 5820XL-EVS: Addressable fire alarm control panel with an emergency voice systems and up to 792 addressable points EVS-50W 28-3176 2.08 For a complete listing of all compliance approvals and certifications, please visit www.silentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Silent Knight® and Honeywell® are registered trademarks of Honeywell International, Inc This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, Please call 800-446-6444. EVS-50W Technical Specifications PHYSICAL Flush Mount Dimensions: 14.5”W x 24.75”H x 3.4”D (36.8 W x 62.9 H x 8.7 D cm) Overall Dimensions: 16.1”W x 26.5”H x 4.1”D (40.6 W x 66.7 H x 10.5 D cm) Color: Red ENVIRONMENTAL Operating Temperature: 32°F to 120°F (0°C to 49°C) Humidity: 10 to 93% relative humidity (non- condensing) ELECTRICAL Primary AC: 120 VAC @ 60Hz Standby Current: 85mA @ 25 Vrms; 100mA @ 70.7Vrms Alarm Current: 525mA @ 25 rms; 580mA @ 70.7Vrm Total Power: 50W @ 25 Vrms or 70.7Vrms • Circuit 1-4: Rated at 50W each • EVS-CE4 Circuits 5-8: Rated at 50W Main ECS Panel SBUS Standby & Alarm: 10mA Battery Charging Capacity: 7 – 35AH Battery Size: 18AH max allowed in cabinet. Use RBB accessory cabinet for larger batteries up to 35AH per system. Voice Integration Wiring: Six conductor Two voice bus Four SBUS T ORDERING INFORMATION EVS-50W: Intelligent 50 Watt Amplifier ACCESSORIES EVS-CE4: Adds four additional audio circuits to the EVS-50W. RBB: Remote Battery Box Accessory Cabinet. Use for backup batteries up to 35 AH. AB55: Remote Battery Box Accessory Cabinet Use for back batteries up to 55AH and too large to fit into EVS-50W Cabinet. AGENCY LISTINGS AND APPROVALS UL 864 and UL 2572 Meets the requirements for NFPA 72 Local Protective Signaling Systems & Emergency Communication Systems. CSFM 7165-559:0172 Doc 350605 | Rev D | 05/18 © 2018 Honeywell International Inc. For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 Pb Yuasa brand NP and NPX batteries give excellent performance in either float or cyclic applications. These batteries are designed for light duty cyclic applications, fire and security systems, Emergency lighting, solar and wind support systems, UPS systems and toys! NP/NPX SERIES SEALED RECHARGEABLE LEAD-ACID BATTERIES NP/NPX INDUSTRIAL BATTERIES POWERING THE NEXT GENERATION TYPE FR TYPE VOLTS NORMAL CAPACITY 10 hr rate (Ah) LENGTH WIDTH OVERALL HEIGHT Incl. TERMINALS WEIGHT LAYOUT TERMI- NALS mm. (in.) mm. (in.) mm. (in.)kgs. (lbs.) NP SERIES 20 hr Rate (Ah) NP1.2-6 – 6 1.2 97 3.82 25 0.98 54.5 2.15 0.3 0.66 1 A NP3-6 –3 134 5.28 34 1.33 64 2.52 0.65 1.43 1 A NP4-6 –4 70 2.76 47 1.85 105.5 4.15 0.85 1.87 5 A NP7-6 –7 151 5.95 34 1.33 97.5 3.84 1.35 2.98 1 A NP10-6 –10 151 5.95 50 1.97 97.5 3.84 2.0 4.41 1 A NP1.2-12 – 12 1.2 97 3.82 48 1.89 54.5 2.15 0.57 1.25 3 A – NP2.3-12FR 2.3 178 7.01 34 1.34 64 2.52 0.94 2.07 1 A NP4-12 –4 90 3.54 70 2.76 106 4.17 1.7 3.74 1 A NP5-12 –5 90 3.54 70 2.76 105 4.13 1.85 4.07 1 B/D NP7-12 NP7-12FR 7 151 5.94 65 2.56 97.5 3.84 2.5 5.51 4 A/D NP7.5-12 –7.5 151 5.94 65 2.56 97.5 3.84 2.65 5.84 4 A/D NP12-12 NP12-12FR 12 151 5.94 98 3.86 97.5 3.84 4.0 8.82 4 D NP18-12B NP18-12BFR 17.2 181 7.13 76.2 2.99 167 6.57 6.2 13.64 2 E NP24-12 NP24-12FR 24 166 6.54 175 6.89 125 4.92 8.65 19.05 2 C NP24-12B NP24-12BFR 24 166 6.54 175 6.89 125 4.92 8.65 19.05 2 E NP38-12B NP38-12BFR 38 197 7.74 165 6.5 175 6.89 13.8 30.4 2 F NP38-12 –38 197 7.74 165 6.5 170 6.69 14.2 31.3 2 J – NP65-12FR 65 350 13.78 166 6.54 174 6.85 22.8 50.2 2 G NPX SERIES W/Cell to 1.67 end voltage (15 Min Rate) NPX-50 –6 50W/Cell 151 5.95 50 1.97 97.5 3.84 2.0 4.41 1 A NPX-25 NPX-25FR 12 23W/Cell 90 3.54 70 2.75 106 4.17 2.0 4.41 1 D NPX-35 NPX-35FR 35W/Cell 151 5.94 65 2.56 97.5 3.84 2.65 6.17 4 A/D – NPX-80BFR 80W/Cell 181 7.13 76.2 2.99 167 6.57 6.6 14.5 2 E – NPX-80RFR 80W/Cell 181 7.13 76.2 2.99 167 6.57 6.6 14.5 2 M5 – NPX-100RFR 95W/Cell 166 6.54 125 4.92 175 6.89 9.3 20.8 2 M5 – NPX-150RFR 150W/Cell 197 7.76 165 6.5 175 6.89 15.5 34.1 2 M6 28-3176 2.12 GS Yuasa Energy Solutions, Inc.2 NP/NPX SERIES SEALED RECHARGEABLE LEAD-ACID BATTERIES The Yuasa brand of small valve-regulated batteries have, since their introduction, set the standard for quality and excellence in the field of rechargeable sealed lead-acid battery technology. This standard has been used as a benchmark in applications such as security, uninterruptible power supplies (UPS), emergency lights and medical equipment. Anywhere the need for reliable and dependable back-up power is required, Yuasa sets the pace. The Yuasa brand NP product line covers the entire spectrum of battery sizes, ranging from 1.2 Ah to 65Ah in 6 and 12 volt varieties. Yuasa also offers a full line of flame retardant batteries (UL94-V0, LOI 30). Designated “FR”, these batteries comply with UL1778 flame retardant specifications for UPS. Yuasa also offers the NPX Series Batteries, designed for high rate discharge applications. These batteries are used primarily where high wattage is required for a short duration. With 50% more wattage available and a 30% reduction in size over conventional batteries, the NPX Series offers a superior value, especially in UPS applications. 3 NP/NPX SERIES SEALED RECHARGEABLE LEAD-ACID BATTERIES GS Yuasa Energy Solutions, Inc. Important notes to prolong battery life: Charging • Standby use: Apply constant voltage charging at 2.275 volts per cell (or 2.25–2.30VPC). Cyclic use: Apply constant voltage charging at 2.40–2.50VPC. • Initial charging current should be set at less than 0.25CA. • Storage- 6 months- Top charge: Apply constant voltage at 2.40 volts per cell, initial charging current should be set at less than 0.1CA for 15 to 20 hours. Discharge • Stop operation when voltage has reached the minimum permissible voltage. Recharge immediately. • Do not operate at 6CA or more current continuously. Storage • Always store battery in a fully charged condition. • If battery is to be stored for a long period, apply a recovery top-charge every 6 months. Temperature • Keep within ambient temperatures of –15˚C to +50˚C for both charging and discharging. Store batteries in a dry and cool location. Incorporating battery into equipment • Encase battery in a well ventilated compartment. • Avoid installing battery near heated units such as a transformer. • House the battery in the lowest section of the equipment enclosure or rack to prevent unnecessary battery temperature rise. Others • Avoid terminal short circuit. DO NOT expose to open flame. • Avoid setting batteries in environments which can cause direct contact to gasoline, paint thinner, organic solvents, synthetic resins, oil, etc… ABOUT GS YUASA ENERGY SOLUTIONS, INC. GS Yuasa Energy Solutions, Inc. is an American subsidiary of GS Yuasa Corporation, the world’s second largest battery company and a 100+ year old Japanese corporation. GS Yuasa Energy Solutions (GYES) was formed in 2019 to address the growing energy storage and reserve power markets. GYES brings together and leverages GS Yuasa Group’s advanced technologies with proven American market successes in lithium, telecom, UPS, alarm & security, and energy storage into a single business unit. GS Yuasa Energy Solutions, Inc. 1150 Northmeadow Pkwy. Suite 110 Roswell, GA 30076 (800) 472-2879 www.gsyuasa-es.com 500-100-092 ver.2.0 9-2019LAYOUT TERMINALS NP/NPX SERIES SEALED RECHARGEABLE LEAD-ACID BATTERIES FEATURES & BENEFITS •Installer can open station without causing an alarm condition •Dual-color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition •Key operated test and reset lock using lock plate actuator •Key matches compatible FACP locks •Meets ADA requirement for 5 lbs maximum pull force to active •Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[13]) •Shell, door, and handle molded from durable LEXAN® •Reliable analog communications for trouble-free operation •Braille text on station handle •Rotary address switches for fast installation • Handle latches in down position and the word Activated appears, clearly indicating the station has been pulled • UL Listed, including UL 38, Standard of Manually Actuated Signaling System • CSFM Listed • ME A Listed SK-PULL-SA / SK-PULL-DA Intelligent Pull Stations The SK-PULL-SA is a single action pull station requiring only one motion to activate the station. The SK-PULL-DA is a dual action pull station requiring two motions to active the station. The SK-PULL-SA and SK-PULL-DA are for use with Honeywell Silent Knight Series fire control panel (FACP). Extremely easy to operate, the SK-PULL-DA and SK-PULL-SA provide a fast and practical means of manually initiating a fire alarm signal. The FACP recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. INSTALLATION The SK-PULL-SA and SK-PULL-DA can be surface mounted to an SB-I/O surface back box or semi-flush mounted on a standard single-gang with a minimum depth of 2.13”(5.40 cm) or double gang or 4” (10.61 cm) square electrical box. You can also use the optional (System Sensor® PN BG-TR) trim ring if the station is being semi-flush mounted. SK-PULL-SA SK-PULL-DA 28-3176 2.15 For a complete listing of all compliance approvals and certifications, please visit www.silentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Silent Knight®, System Sensor® and Honeywell® are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 800-446-6444. SK-PULL-SA / SK-PULL-DA Technical Specifications PHYSICAL Dimensions: 5.5” H x 4" W x 1.45" D (14 x 10.2 x 3.7cm) Housing Material: LEXAN polycarbonate resin Bi-Colored LED: Blinking Green: Normal Steady Red: Alarm Switch: Single pole, single throw (SPST) normally open (N/O) switch which closes upon activation of the pull station ELECTRICAL Operating Voltage: 15 – 32VDC SLC Standby and Alarm Current: 350μ A Wire Gauge: Up to 12AWG (3.1 mm2) ENVIRONMENTAL Operating Temperature: 32ºF – 120ºF (0ºC – 49ºC) Humidity: 10% – 93% non-condensing ORDERING INFORMATION SK-Pull-SA: Single Action Pull Station SK-Pull-DA: Dual Action Pull Station ACCESSORIES BG-TR: Optional trim ring. SB-I/O: Surface backbox, indoor/outdoor. * Unless otherwise noted, specifications apply to SK-Pull-SA and SK-Pull-DA COMPATIBILITY The SK-PULL-SA AND SK-PULL-DA are compatible with the following Honeywell Silent Knight fire alarm control panels: 6820: Addressable fire alarm control panel 6820EVS: Addressable fire alarm control panel with an emergency voice system. 6808: Addressable fire alarm control panel 6700: Addressable fire alarm control panel 5700: Addressable fire alarm control panel 5808: Addressable fire alarm control panel 5820XL: Addressable fire alarm control panel 5820XL-EVS: Addressable fire alarm control panel with an emergency voice system Doc 350135 | Rev E | 11/17 © 2017 Honeywell International Inc. For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 SK-HEAT-W SERIES Addressable Heat Detectors The Silent Knight® SK-HEAT-W Series heat detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and advanced thermal technologies make the SK-HEAT-W Series ideal for both system operation and building design. The series includes a 135°F/57°C fixed-temperature, rate-of-rise, and a 180°F/88°C fixed high-temperature detectors and are direct replacements for the SK-HEAT Series heat detectors. The point ID address, set using rotary decimal switches, provide specific detector locations. These thermal detectors provide effective, intelligent property protection in a variety of applications. • SK-HEAT-W offers 135°F fixed thermal detection. • SK-HEAT-ROR-W offers 135°F fixed and rate-of-rise thermal detection. • SK-HEAT-HT-W provides fixed high-temperature detection at 190°F. FEATURES AND BENEFITS • Designed to meet UL 268 7th Edition • Sleek and stylish contemporary design • Advanced thermal technology for fast response • Fixed temperature model (SK-HEAT-W) factory preset to 135°F (57°C) •Rate-of-rise model (SK-HEAT-ROR-W), 15°F (8.3°C) per minute • High temperature model (SK-HEAT-HT-W) factory preset to 190°F (88°C) • Addressable by device • Rotary, decimal addressing (Refer to the Silent Knight panel manuals for device capacity) • Two-wire SLC connection • LEDs blink every time the unit is polled • 360°-field viewing angle of the visual alarm indicators (two bi-color LEDs); LEDs blink green in Normal condition and turn on steady red in Alarm • Integral communications and built-in device-type identification • Remote test feature from the panel • Built-in functional test switch activated by external magnet • Walk test with address display (an address of 121 will blink the detector LED 12- (pause)-1) • Low standby current • Built-in tamper-resistant feature • Designed for direct-surface or electrical- box mounting • Sealed against back pressure • Plugs into separate base for ease of installation and maintenance • SEMS screws for wiring of the separate base • Optional remote, single-gang LED accessory • Optional sounder, relay, and isolator bases • Optional flanged surface mounting kit 28-3176 2.17 Page 2 of 3 — 351637:B • 7/1/2019 APPLICATIONS Use thermal detectors for protection of property. For further information, refer to manual I56-6529, Applications Manual for System Smoke Detectors, which provides detailed information on detector spacing, placement, zoning, wiring, and special applications. INSTALLATION The SK-HEAT-W Series plug-in intelligent thermal detectors use a separate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see SK-61045. Note: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring “T-taps” or branches are permitted for Style 4 (Class “B”) wiring. Note: When using relay or sounder bases, consult the SK-ISO installation sheet I56-3627 for device limitations between isolator modules and isolator bases. PRODUCT LINE INFORMATION SK-HEAT-W: White, low-profile intelligent 135°F fixed thermal sensor SK-HEAT-ROR-W: White, low-profile intelligent rate-of-rise thermal sensor SK-HEAT-HT-W: White, low-profile intelligent 190°F fixed thermal sensor B300-6: White, standard flanged low-profile mounting base B300-6-BP: Bulk pack of B300-6, package contains 10 B300-6-IV: Ivory, standard flanged low-profile mounting base B501-WHITE: White, standard European flangeless mounting base B501-BL: Black, standard European flangeless mounting base B501-IV: Ivory, standard European flangeless mounting base B501-WHITE-BP: Bulk pack of B501-WHITE, contains 10 B200S-WH: White, Intelligent, programmable sounder base B200S-IV: Ivory, Intelligent, programmable sounder base B200SR-WH: White, Intelligent sounder base for retrofit applications B200SR-IV: Ivory, Intelligent sounder base for retrofit applications B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base B200SR-LF-WH: White, Low Frequency Intelligent sounder base for retrofit applications B200SR-LF-IV: Ivory, Low Frequency Intelligent sounder base for retrofit applications B224RB-WH: White, plug-in System Sensor® relay base B224RB-IV: Ivory, plug-in System Sensor relay base B224BI-WH: White, plug-in System Sensor isolator detector base B224BI-IV: Ivory, plug-in System Sensor isolator detector base ACCESSORIES TR300: White, replacement flange for B210LP or B300-6 bases TR300-IV: Ivory, replacement flange for B210LP or B300-6 bases RA100Z(A): Remote 3 – 32 VDC LED annunciator, mounts to a U.S. single-gang electrical box, for use with B501 and B300-6 bases only M02-04-00: Test magnet M02-09-00: Test magnet with telescoping handle CK300: White, detector color kit, pack of 10 CK300-IV: Ivory, detector color kit, pack of 10 CK300-BL: Black, detector color kit, pack of 10 SK-HEAT-W SERIES TECHNICAL SPECIFICATIONS 351637 | B | 07/19 ©2019 Honeywell International Inc. Silent Knight® and System Sensor® are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Country of origin: Mexico PHYSICAL/ENVIRONMENTAL Size: 2.0" (5.3 cm) high; base determines diameter -B300-6: 6.1" (15.6 cm) diameter -B501: 4" (10.2 cm) diameter For a complete list of detector bases, see SK-61045. Operating temperature range: SK-HEAT-W, SK-HEAT-ROR-W: -4°F to 100°F (-20°C to 38°C) SK-HEAT-HT-W: -4°F to 150°F (-20°C to 66°C) Detector spacing: UL approved for 50 ft. (15.24 m) center to center; FM approved for 25 x 25 ft. (7.62 x 7.62 m) spacing Relative humidity: 10% – 93% non- condensing Thermal ratings: Fixed-temperature set point 135°F (57°C), rate-of-rise detection 15°F (8.3°C) per minute, high temperature heat 190°F (88°C) ELECTRICAL SPECIFICATIONS Voltage range: 15 - 32 volts DC peak Standby current (max. avg.): 200uA @ 24 VDC (one communication every 5 seconds with LED enabled) LED current (max.): 4.5mA @ 24 VDC (“ON”) Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.silentknight.com AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document.In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. •UL Listed: S6228 • FM Approved •CSFM: 7270-0559:0511 SK-PHOTO-W SERIES Addressable Photoelectric Smoke Detectors The Silent Knight® SK-PHOTO-W Series feature a modern design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and maintenance efficiency. The SK-PHOTO-W Series intelligent plug-in smoke detectors are designed for both performance and aesthetics, and are direct replacements for the SK-PHOTO Series detectors. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The SK-PHOTO-W Series detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector’s address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135°F (57°C) fixed temperature thermal sensing on the SK-PHOTO-T-W. The SK-PHOTO-R-W is a remote test capable detector for use with DNR Series duct detector housings. FEATURES AND BENEFITS • Designed to meet UL 1268 7th Edition • Sleek and stylish contemporary design • Stable communication technique with noise immunity • Addressable by device • Rotary, decimal addressing (Refer to the Silent Knight panel manuals for device capacity) • Two-wire SLC connection • LEDs blink every time the unit is polled • 360°-field viewing angle of the visual alarm indicators (two bi-color LEDs); LEDs blink green in Normal condition and turn on steady red in Alarm • Integral communications and built-in device-type identification • Remote test feature from the panel • Built-in functional test switch activated by external magnet • Walk test with address display (an address of 121 will blink the detector LED 12- (pause)-1) • Low standby current • Built-in tamper-resistant feature • Designed for direct-surface or electrical- box mounting • Sealed against back pressure • Plugs into separate base for ease of installation and maintenance • Expanded color options • SEMS screws for wiring of the separate base • Optional remote, single-gang LED accessory • Optional sounder, relay, and isolator bases 28-3176 2.18 Page 2 of 3 — 351634:B • 7/1/2019 INSTALLATION The SK-PHOTO-W Series plug-in intelligent thermal detectors use a separate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see SK-61045. Note: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring “T-taps” or branches are permitted for Style 4 (Class “B”) wiring. Note: When using relay or sounder bases, consult the SK-ISO installation sheet I56-3627 for device limitations between isolator modules and isolator bases. OPERATION Each SK-PHOTO-W Series detector uses one of the panel’s addresses (total limit is panel dependent) on the Signaling Line Circuit (SLC). It responds to regular polls from the control panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The SK-PHOTO-W Series offers features and performance that represent the latest in smoke detector technology. PRODUCT LINE INFORMATION Note: “-IV” suffix indicates ivory color. SK-PHOTO-W: White, low-profile photoelectric sensor SK-PHOTO-T-W: White, same as SK-PHOTO-W but includes a built-in 135°F (57°C) fixed-temperature thermal device SK-PHOTO-R-W: White, low-profile intelligent photoelectric sensor, remote test capable, for use with DNR/DNRW B300-6: White, standard flanged low-profile mounting base B300-6-BP: Bulk pack of B300-6, package contains 10 B300-6-IV: Ivory, standard flanged low-profile mounting base B501-WHITE: White, standard European flangeless mounting base B501-BL: Black, standard European flangeless mounting base B501-IV: Ivory, standard European flangeless mounting base B501-WHITE-BP: Bulk pack of B501-WHITE, contains 10 B200S-WH: White, Intelligent, programmable sounder base B200S-IV: Ivory, Intelligent, programmable sounder base B200SR-WH: White, Intelligent sounder base for retrofit applications B200SR-IV: Ivory, Intelligent sounder base for retrofit applications B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base B200SR-LF-WH: White, Low Frequency Intelligent sounder base for retrofit applications B200SR-LF-IV: Ivory, Low Frequency Intelligent sounder base for retrofit applications B224RB-WH: White, plug-in System Sensor® relay base B224RB-IV: Ivory, plug-in System Sensor relay base B224BI-WH: White, plug-in System Sensor isolator detector base B224BI-IV: Ivory, plug-in System Sensor isolator detector base ACCESSORIES TR300: White, replacement flange for B210LP or B300-6 bases TR300-IV: Ivory, replacement flange for B210LP or B300-6 bases RA100Z(A): Remote 3 – 32 VDC LED annunciator, mounts to a U.S. single-gang electrical box, for use with B501 and B300-6 bases only M02-04-00: Test magnet M02-09-00: Test magnet with telescoping handle CK300: White, detector color kit, pack of 10 CK300-IV: Ivory, detector color kit, pack of 10 CK300-BL: Black, detector color kit, pack of 10 SK-PHOTO-W SERIES TECHNICAL SPECIFICATIONS 351634 | B | 07/19 ©2019 Honeywell International Inc. Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.silentknight.com Silent Knight® and System Sensor® are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Country of origin: Mexico PHYSICAL/ENVIRONMENTAL Sensitivity: -UL Applications: 0.5% to 4.0% per foot obscuration. -ULC Applications: 0.5% to 3.5% per foot obscuration Size: 2.0" (5.3 cm) high; base determines diameter - B300-6: 6.1" (15.6 cm) diameter - B501: 4" (10.2 cm) diameter For a complete list of detector bases, see SK-61045. Shipping weight: 3.4 oz. (95 g) Operating temperature range: • SK-PHOTO-W: 32°F to 122°F (0°C to 50°C) • SK-PHOTO-T-W: 32°F to 100°F(0°C to 38°C) • SK-PHOTO-R-W installed in a DNR/DNRW: -4°F to 158°F (-20°C to 70°C) UL/ULC Listed Velocity Range: 0-4000 ft/ min. (1219.2 m/min.), suitable for installation in ducts Relative humidity: 10% – 93% non- condensing Thermal ratings: fixed-temperature set point 135°F (57°C), rate-of-rise detection 15°F (8.3°C) per minute, high temperature heat 190°F (88°C) ELECTRICAL SPECIFICATIONS Voltage range: 15 - 32 volts DC peak Standby current (max. avg.): 200µA @ 24 VDC (one communication every 5 seconds with LED enabled) Max current: 4.5 mA @ 24 VDC (“ON”) DETECTOR SPACING AND APPLICATIONS Silent Knight recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.1m). For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. A System Smoke Detector Application Guide, document A05-1003, is available at www.systemsensor.com. AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document.In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. •UL Listed: S6173 • FM Approved •CSFM: 7272-0559:0512 FEATURES & BENEFITS •Versatile mounting options: square or rectangular configuration •New Cover tamper signal •LED alarm indication and communication on sensor head •Detects and limits the spread of smoke •Rugged steel back box with clear plastic cover •Easy to clean •Large terminal connection screws •Transparent cover for convenient visual inspection •Patented sampling tube installs from front or back of the detector with no tools required •Available space within housing to accommodate mounting of relay module •UL listed SK-DUCT Intelligent Air Duct Smoke Detector The SK-DUCT Intelligent air duct smoke detector is used with SK-PHOTOR (included) for detecting smoke and products of combustion present in air moving through an HVAC air handling system. When smoke is detected in a duct, the unit communicates the condition to the Honeywell Silent Knight control panel. The panel, in turn, depending on programming and wiring, turns off fans, blowers, and other devices. The duct housing allows for mounting of SK-RELAY addressable relay module. The Model SK-DUCT Air Duct Smoke Detector utilizes photoelectric technology for the detection of smoke. It provides early detection of smoke and products of combustion present in air moving through HVAC ducts in Commercial and Industrial applications. The SK-DUCT is in a heavy duty gray steel back box with a clear cover. It features a pivoting housing that fits both square and rectangular footprints capable of mounting to a round or rectangular duct. It installs quickly and easily. The unit senses smoke in the most challenging conditions, operating in airflow speeds of 100 to 4000 feet per minute, temperatures of -4°F to 158°F, and a humidity range of 0 to 95 percent (non-condensing). SK-DUCT 28-3176 2.19 For a complete listing of all compliance approvals and certifications, please visit www.silentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Silent Knight®, System Sensor® and Honeywell® are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 800-446-6444. SK-DUCT Technical Specifications PHYSICAL (Rectangular): 14.38" (37 cm) L X 5" (12.7 cm) W X 2.5" (6.6 cm) D (Square): 7.75" (19.7cm) L x 9"(22.9cm) W x 2.5" D (6.35cm) Weight: 1.6lb (0.73kg) ELECTRICAL (using SK-Photo or SK-PhotoR) Operating Voltage: 15–32 VDC Standby Current: 300 μ A @ 24 VDC max. Alarm Current: 6.5 mA @ 24 VDC max (with LED on) ENVIRONMENTAL Operating Temperature: -4ºF – 158ºF (-20ºC – 70ºC) Humidity: 0% – 95% (non-condensing) AIR VELOCITY 100 to 4000 ft/min: (0.5 – 20.3 m/sec.) ORDERING INFORMATION SK-DUCT: Intelligent non-relay duct smoke detector SK-PHOTO: Addressable Photo Detector SK-PHOTOR: Addressable Photo Detector with remote test capability (included with SK-Duct) SK-RELAY: Addressable Relay Module, must be added if relay function is required, (fits in housing) ACCESSORIES DST1: Metal Sampling Tube Duct Width up to 1’ DST1.5: Metal Sampling Tube Duct Widths 1’ - 2’ DST3: Metal Sampling Tube Duct Widths 2’ – 4’ DST5: Metal Sampling Tube Duct Widths 4’ – 8’ DST10: Metal Sampling Tube Duct Widths 8’ – 12’ DH400OE-1: Weatherproof Enclosure ETX: Metal Exhaust Tube Duct width 1’ RA100Z: Remote LED Annunciator DCOIL: Duct accessory coil, required if using with SK-PHOTO and not SK-PHOTOR (included) with SK-DUCT RTS151: Magnetic Remote Test station RTS151KEY: Key-Activated Remote Test station M02-04-00 Test Magnet P48-21-00 Replacement End Cap for Metal Sampling Tube APA151: Remote annunciator with piezo alarm IMPORTANT NOTES: • The use of either RTS151 or RTS151KEY requires the installation of an accessory coil, DCOIL, sold separately. Please refer to the SK-DUCT installation instructions for more information • The RTS151/RTS151KEY test coil circuit requires an external 24VDC power supply which must be UL listed. ACCESSORY CURRENT LOADS AT 24VDC Device Standby Alarm RA100Z 0mA 12mA Max. RTS151 0mA 12mA Max RTS151KEY 12mA 12mA Max Doc 350122 | Rev F | 11/17 © 2017 Honeywell International Inc. For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 COMPATIBILITY The SK-DUCT is compatible with the following Honeywell Silent Knight fire alarm control panels: 6820: Addressable fire alarm control panel 6820EVS: Addressable fire alarm control panel with an emergency mass notification system. 6808: Addressable fire alarm control panel 6700: Addressable fire alarm control panel 5700: Addressable fire alarm control panel 5808: Addressable fire alarm control panel 5820XL: Addressable fire alarm control panel 5820XL-EVS: Addressable fire alarm control panel with an emergency mass notification system. 1 I56-0758-016 06-10 SPECIFICATIONS Dimensions: 4.6˝ H × 2.75˝ W × 1.8˝ D Weight: 0.24 Lbs. Power Requirements Power LED (Green): 14 – 35 VDC, 12 mA maximum Alarm LED (Red): 2.8 – 32 VDC, 12 mA maximum Alarm Response Time: 40 seconds maximum Temperature: –10°C to 60°C (14°F to 140°F) Humidity: 95% relative humidity, noncondensing Max Listing: UL, FM, CE RTS151KEY(A) Remote Test Station INSTALLATION AND MAINTENANCE INSTRUCTIONS I56-0758-0163825 Ohio Avenue, St. Charles, Illinois 60174 1.800.SENSOR2; Fax: 630.377.6495 www.systemsensor.com NOTE: RTS151KEY(A) replaces RTS451KEY. NOTICE: This manual shall be left with the owner/user of this equipment. NOTE: A test coil is required only for use with D2/DNR/DH400/DH500 mod- els. For D2 models order part # DCOIL. For DH400/500 models order part #Coil. GENERAL INFORMATION The System Sensor RTS151KEY(A) is an automatic fire detector accessory de- signed to test remotely located duct and beam detectors. For 4-wire detec- tors, the RTS151KEY(A) features a multi-colored LED that alternates between steady green and red. Green indicates power and that the detector board is in place. Red indicates alarm. For 2-wire detectors, the LED will show red for alarm. Consult the detector installation instructions for additional informa- tion. The National Fire Protection Association has published codes, standards, and recommended practices for the installation and use of this product. It is rec- ommended that the installer be familiar with these requirements, with local codes, and any special requirements of the local authority having jurisdiction. RTS151 CONTENTS 1 RTS151KEY(A) remote test station 1 screw pack (2 mounting screws) 2 Keys OPERATION Test Function Insert the key and turn clockwise to the “TEST” position. Alarm Indication With the key in the “TEST” position, some time will elapse (40 seconds maxi- mum) depending on the detector type, before the alarm indicating LED will turn red. Reset Function Turn the key counterclockwise to the “RESET” position and hold. The LED should turn off. Then, turn the key back to the “NORMAL” position and re- move. The RTS151KEY(A) is capable of resetting only certain models of detec- tors. Refer to the detector installation instructions for additional information. Wiring Instructions Consult the appropriate detector installation instructions for the applicable wiring diagram. The RTS151KEY(A) mounts to a single gang box (2 1/2˝ mini- mum depth), or directly to the wall or ceiling. In Canadian applications, the RTS151KEY(A) is intended to be located in the same room as the smoke detector and within 60 feet of the unit. H0195-01 H0582-21 FIGURE 1. RTS151KEY(A) FIGURE 2: WIRING DIAGRAM FOR RTS151KEY(A) TO D4120 4-WIRE DUCT SMOKE DETECTOR: 19 20 15 2 6 1 5 4 3 D4120RTS451KEY(A) (GREEN LED) POWER (RED LED) ALARM FIELD INSTALLED JUMPER 11 2 AUX OUT + AUX OUT – ALARM R TEST R RESET 14 3 SUP, NO SUP, C * Sup. contacts cannot be used if they are wired to control panel. * FIGURE 3: WIRING DIAGRAM FOR RTS151KEY(A) TO DNR 2-WIRE DUCT SMOKE DETECTOR WITH REMOTE TEST CAPABLE HEAD: H0633-00 RTS451/RTS451KEY RTS151/RTS151KEY JUMPER 4 5 3 2 1 TEST COIL + TEST COIL – COMM + OUT (CONV ONLY) + COMM – RA/RTS – RA + RTS + 28-3176 2.20 2 I56-0758-016 ©2016 System Sensor. 06-10 FIGURE 4: WIRING DIAGRAM FOR RTS151KEY(A) TO D2 2-WIRE DUCT SMOKE DETECTOR: H0612-12 24 VAC (+10%, –15%) FULL WAVE RECTIFIED, UNFILTERED POWER MAY BE USED RTS151KEY(A) (OPTIONAL) REMOTE TEST STATION MAGNET TEST SWITCH ALARMLED (RED) 4 5 2 1 (+) (–) + RA + RTS – RA + TEST COIL – TEST COIL + IN + OUT – (–) (+) D2 24 VDCAUX POWER SUPPLIED BY USER (100mA SUPPLY) RTS151KEY(A) (OPTIONAL) REMOTE TEST STATION 24 VAC (+10%, –15%)FULL WAVE RECTIFIED, UNFILTERED POWER MAY BE USED MAGNET TEST SWITCH ALARM LED (RED) 4 5 2 1 (+) (–) + RA + RTS – RA + TEST COIL – TEST COIL + IN + OUT – 24 VDCAUX POWER SUPPLIEDBY USER (100mASUPPLY) D2 NOTE: THE USE OF THE RTS151KEY(A) REQUIRES THE INSTALLATION OF AN ACCESSORY COIL, DCOIL, SOLD SEPARATELY. METHOD #1 - AUX POWER LOCATED AT DUCT DETECTOR METHOD #2 - AUX POWER LOCATED AT TEST STATION FIGURE 5. WIRING DIAGRAM FOR RTS151KEY(A) TO DH100ACDC 4-WIRE DUCT SMOKE DETECTOR: FIGURE 6. WIRING DIAGRAM FOR RTS151KEY(A) TO DH100 2-WIRE DUCT SMOKE DETECTOR: NOTE: Terminal 6 of the RTS151KEY(A) is not used when wired to a 2-wire detector. 15 19 14 3 20 2 11 2 6 1Alarm Signal Aux. Power + Sup. N. O. Sup. COM Aux. Power “ Reset Test (Red LED) Alarm (Green LED) Power DH100ACDCLP RTS151KEY(A) 5 4 3 ** Sup. contacts cannot be used if they are wired to control panel. 1 2 3 4 5 6 3 4 5Test + Test / Reset – Reset + Test ResetRA + RA – V Out + DH100 RTS151KEY(A) 6 2 1 Alarm LED No Connection H0193-05H0156-08 THREE-YEAR LIMITED WARRANTY System Sensor warrants its enclosed product to be free from defects in materials and workmanship under normal use and service for a period of three years from date of manufacture. System Sensor makes no other express warranty for the enclosed product. No agent, representative, dealer, or employee of the Company has the authority to in- crease or alter the obligations or limitations of this Warranty. The Company’s obligation of this Warranty shall be limited to the replacement of any part of the product which is found to be defective in materials or workmanship under normal use and service during the three year period commencing with the date of manufacture. After phoning System Sensor’s toll free number 800-SENSOR2 (736-7672) for a Return Authorization number, send defective units postage prepaid to: Honeywell, 12220 Rojas Drive, Suite 700, El Paso TX 79936, USA. Please include a note describing the malfunction and suspected cause of failure. The Company shall not be obligated to replace units which are found to be defective because of damage, unreasonable use, modifications, or alterations occurring after the date of manufacture. In no case shall the Company be liable for any consequen- tial or incidental damages for breach of this or any other Warranty, expressed or implied whatsoever, even if the loss or damage is caused by the Company’s negligence or fault. Some states do not allow the exclusion or limitation of incidental or consequential dam- ages, so the above limitation or exclusion may not apply to you. This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state. FIGURE 7. WIRING DIAGRAM FOR RTS151KEY(A) TO DH400ACDC DUCT SMOKE DETECTOR: 5 7 11 10 6 3 4 2 6 1Alarm Signal Aux. Power + Sup. N. O. Sup. COM Aux. Power – Reset Test (Red LED) Alarm (Green LED) Power DH400ACDC RTS151KEY(A) 5 4 3 ** Sup. contacts cannot be used if they are wired to control panel. H0156-09 FIGURE 8. WIRING DIAGRAM FOR RTS151KEY(A) TO BEAM1224/ BEAM1224T SMOKE DETECTOR: H0585-04 1 2 3 4 5 3 2 1 5 4 RTS151KEY(A)BEAM1224/BEAM1224T REMOTE ALARM OUT AUX (–) TEST INPUT REMOTE TROUBLE OUTPUT RESET INPUT TEST RESET T2-3 T3-3 T2-4 T2-2 T2-1 OPTIONAL YELLOW LED NOTE: RTS151KEY(A) CAN BE USED WITH INTELLIGENT BEAM DETECTOR PRODUCTS. CONSULT INTELLIGENT BEAM DETECTOR MANUAL FOR ADDITIONAL INSTRUCTIONS (RED LED) ALARM Agency Listings CO1224 Series Carbon Monoxide Detectors with RealTest® Technology The System Sensor CO1224T, CO1224TR, and CO1224A (Canada) Carbon Monoxide (CO) Detectors use a highly accurate and reliable electrochemical sensing cell to provide early warning of dangerous CO levels. Features • A 10-year end-of-life timer • RealTest® enables a functional test using canned CO • A code-required trouble relay • Wiring supervision with SEMS terminals • 12/24 VDC • A low current draw of 20 mA in standby and 40 mA in alarm • Versatile mounting for wall and ceiling • Accurate and reliable electrochemical sensing technology • Optional CO-PLATE CO Detector Replacement Plate to upgrade previously installed competitor detectors to the CO1224T or CO1224A. • CO1224T tested up to 12,000 feet above sea level When dangerous amounts of CO are detected, the CO1224 Series CO detectors alert residents by sounding and fl ashing a temp 4 signal alarm. With 24/7 central station monitoring, residents are guaranteed protection whether they are away from home, sleeping, or already suffering from the effects of CO. The CO1224 Series detectors are designed for system operation. These detectors are fully listed to UL 2075 (US models only) and CSA 6.19-01 (Canada model only) and offer a code-required trouble relay to send a sensor failure or end-of-life signal to the control panel and the central station. The CO1224 Series detectors also use SEMS-type terminal Philips head screws for quicker and more positive wiring connections and code-required wiring supervision. With a low current draw, these detectors enable more devices to be connected to the panel, limiting the need to purchase extra power supplies or more expensive panels. As 12/24 VDC detectors, the CO1224 Series detectors will operate on most industry security and fi re alarm control panels. With RealTest® technology, the CO gas sensing cell used in the CO1224 Series CO detectors can be tested using a CO gas agent, fully meeting the requirements of NFPA 720: 2009 (US models only). Simply put the detector into RealTest mode, spray a small amount of CO into the detector per the installation instructions, and within seconds the detector will alarm, indicating successful gas entry. (See the reverse page or the user manual for complete instructions.) E307195 E304075 Note: CO1224T & CO1224TR are in full compliance with UL 2075 and CO1224A is in full compliance with ULC CSA 6.19-01. CO1224T CO1224A CO1224TR 28-3176 2.21 US: 3825 Ohio Avenue St. Charles, IL 60174 800-SENSOR2 systemsensor.com ©2016 System Sensor. Product specifi cations subject to change without notice. Visit our websites for current product information, including the latest version of this data sheet. CODS88600 • 10/16 Canada: 6581 Kitimat Rd, Unit 6 Mississauga, Ontario L5N 3T5 800-SENSOR2 systemsensor.ca Ordering Information Part No.Description CO1224T 12/24 volt, 6-wire system-monitored carbon monoxide detector with RealTest® Technology (US only) CO1224TR 12/24 volt, 6-wire system-monitored round carbon monoxide detector with RealTest ® Technology (US only) CO1224A 12/24 volt, 6-wire system-monitored carbon monoxide detector with RealTest ® Technology (Canada only) CO-PLATE CO detector replacement plate to cover the footprint of previously installed competitive detectors (US & Canada) CO1224 Series Detectors Carbon Monoxide Detector Specifications Architectural/Engineering Specifi cations Carbon monoxide (CO) detector shall be a system-connected System Sensor model number CO1224T or CO1224TR listed to Underwriters Laboratories UL 2075 for Gas and Vapor Detectors and Sensors. The Canadian model CO1224A, is ULC listed to CSA 6.19-01, for residential carbon monoxide alarm devices. The detector shall be equipped with a sounder and a trouble relay. The detector’s base shall be able to mount to a single-gang electrical box or direct (surface) mount to the wall or ceiling. Wiring connections shall be made by means of SEMS screws. The detector shall provide dual-color LED indication that blinks to indicate normal standby, alarm, or end-of-life. When the sensor supervision is in a trouble condition, the detector shall send a trouble signal to the panel. When the detector gives a trouble or end-of-life signal, the detector shall be replaced. The detector shall provide a means to test CO gas entry into the CO sensing cell. The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry. For the CO1224T only, the detector shall perform in the detection of CO up to 12,000 feet above sea level and alarm within the time specifi ed by ANSI/UL 2034 for CO concentrations of 70, 150 and 400 parts per million (ppm), as verifi ed by a Nationally Recognized Test Laboratory. Electrical Specifi cations Operating Voltage 12/24 VDC Audible Signal 85 dB in alarm Standby Current 20 mA Alarm Current 40 mA (75 mA test) Alarm Contact Ratings 0.5 A @ 30 VDC Trouble Contact Ratings 0.5 A @ 30 VDC Physical Specifi cations Size: CO1224T & CO1224A Length: 5.1 in (130 mm), Width: 3.3 in (84 mm), Height: 1.3 in (33 mm) Size: CO1224TR Diameter: 6.0 in (152 mm), Height: 1.3 in (33 mm) Approximate Weight CO1224T & CO1224A: 7 oz (198 g); CO1224TR: 11 oz (312 g) Operating Temperature Range 32°F to 104° F (0°C to 40° C) Operating Humidity Range 22 to 90% RH Input Terminals 14 to 22 AWG Mounting Single-gang back box; surface mount to wall or ceiling Operation Modes Operation Mode Green LED Red LED Sounder Normal (standby)Blink 1 per minute —— Alarm —Blink in temp 4 pattern Sound in temp 4 pattern RealTest® Feature: The System Sensor CO1224 Series CO Detectors enable evaluation of the functionality of the CO sensing cell using a canned CO test agent. Hush Feature: Pushing the Test/Hush button will silence the sounder for 5 minutes (except in RealTest mode). Trouble Feature: When the detector is in a trouble condition, it will send a trouble signal to the panel. End-of-Life Timer: After the detector’s internal sensor has reached the end of its life, a trouble signal will be sent to the panel to indicate it is time to replace the detector. An electrochemical CO detector lifespan is about ten years. The detector must be replaced by the date marked on the inside of the product. CO-PLATE: System Sensor also offers the CO-PLATE CO Detector Replacement Plate to cover the footprint (when necessary) of previously installed competitive carbon monoxide detectors that require replacement. CO-PLATE 3. Push and hold the Test/Hush button for two seconds to enter RealTest mode. The green LED will fl ash once every second to indicate RealTest mode has started. Spray canned CO agent into the detector. Verify CO sensing at the control panel. The detector will automatically exit RealTest alarm mode after about 20-60 seconds. 1.2.NOTE: Check with local codes and the AHJ to determine if a functional gas test is desired for an installation. Agency Listings 7125-1653:0504 7135-1653:0503 S5512 S4011 FM approved except for ALERT models 3057383, 3057072 AVDS865-05 • 2/22/2018 • Page 1 Features •Updated Modern Aesthetics •Small profile devices for Horns and Horn Strobes •Plug-in design with minimal intrusion into the back box •Tamper-resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field-selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 •Horn rated at 88+ dBA at 16 volts •Rotary switch for horn tone and two volume selections •Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before device installation •Electrically compatible with legacy SpectrAlert and SpectrAlert Advance devices •Compatible with MDL3 sync module •Strobes and Horn Strobes listed for wall mounting only •Horns listed for wall or ceiling use The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. 28-3176 2.24 AVDS865-05 • 2/22/2018 • Page 2 L-Series Specifications Architect/Engineer Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 17/8-inch back box, 4 × 4 × 1½-inch back box, 4-inch octagon back box, or double-gang back box. L-Series compact products shall mount to a single-gang 2 × 4 × 17⁄8 -inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize Strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 × 411/16 × 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens)5.6˝ L × 4.7˝ W × 1.91˝ D (143 mm L × 119 mm W × 49 mm D) Compact Wall-Mount Dimensions (including lens)5.26” L x 3.46” W x 1.91” D (133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6˝ L × 4.7˝ W × 1.25˝ D (143 mm L × 119 mm W × 32 mm D) Compact Horn Dimensions 5.25” L x 3.45” W x 1.25” D (133 mm L x 88 mm W x 32 mm D) 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. AVDS865-05 • 2/22/2018 • Page 3 Horn and Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9*Coded High 85 90 90 10*3.1 KHz Coded High 84 89 89 * Settings 9 and 10 are not available on 2-wire horn strobes. Temporal coding must be provided by the NAC. If the NAC voltage is held constant, the horn output remains constantly on. UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC DC FWR Candela Range 15 88 43 60 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 UL Max. Current Draw (mA RMS), Wall Horn Strobe, Candela Range (15–185 cd) DC Input 8–17.5 Volts 16–33 Volts 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 FWR Input 16–33 Volts 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 UL Max. Horn Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Current Draw Data Horn Tones and Sound Output Data 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2018 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS865-05 • 2/22/2018 L-Series Dimensions Model Description Wall Horn Strobes P2RL 2-Wire, Horn Strobe, Red P2WL 2-Wire, Horn Strobe, White P2GRL 2-Wire, Compact Horn Strobe, Red P2GWL 2-Wire, Comp 2 fils act Horn Strobe, White P2RL-P 2-Wire, Horn Strobe, Red, Plain P2WL-P 2-Wire, Horn Strobe, White, Plain P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO P2WL-SP 2-Wire, Horn Strobe, White, FUEGO P4RL 4-Wire, Horn Strobe, Red P4WL 4-Wire, Horn Strobe, White Wall Strobes SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT L-Series Ordering Information Notes: All -P models have a plain housing (no “FIRE” marking on cover). All -SP models have “FUEGO” marking on cover. All -ALERT models have “ALERT” marking on cover. *Horn-only models are listed for wall or ceiling use. Model Description Horns* HRL*Horn, Red HWL*Horn, White HGRL*Compact Horn, Red HGWL*Compact Horn, White Accessories TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBRL Wall Surface Mount Back Box, Red SBBWL Wall Surface Mount Back Box, White SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, White 4.70" (11.94 cm)1.91" (4.85 cm) 1.25" (3.18 mm) 5.67" (14.4 cm) A0549-00A0550-00 Compact Strobe, Horn Strobe Compact Horn Strobe, Horn Strobe Horn A0548-00 A0547-00 4.7" 119 mm 5.67" 144 mm 1.25" 32 mm 3.46" 88 mm 1.91" 48.5 mm 1.25" 32 mm 5.27" 133.9 mm 3.46" 88 mm 1.25" 32 mm 5.27" 133.9 mm Wall Surface Mount Back Box SBBRL/SBBWL A0554-01 4.82" (12.24 cm)1.85" (4.69 cm) 5.78" (14.68 cm) A0557-00 1.55" (3.9 cm) 3.57" (9.1 cm) 5.38" (13.7 cm) Compact Wall Surface Mount Back Box SBBGRL, SBBGWL AVDS866-03 • 03/23/2018 • Page 1 Indoor Selectable- Output Speaker Strobes and Dual Voltage Evacuation Speakers for Ceiling Applications System Sensor L-Series selectable-output speaker strobes and dual-voltage evacuation speakers can reduce ground faults and enable faster installation with lower current draw and modern aesthetics. Features •Plug-in design and protective cover reduce ground faults • Universal mounting plate with an onboard shorting spring tests wiring continuity before installation •No extension ring required • Field selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Rotary switch simplifies field selection of speaker voltage (25 and 70.7 Vrms) and power settings (¼, ½, 1 and 2 watts) •Speakers offer high fidelity and high volume sound output •520 Hz +/- 10% square wave tone capable with compatible FACP •Compatible with System Sensor synchronization protocol •Electrical compatibility with existing SpectrAlert and SpectrAlert Advance products •Tamper-resistant construction •Updated modern aesthetics System Sensor L-Series of speakers and speaker strobes reduce costly ground faults using a plug-in design and universal mounting plate that allow the installer to pre-wire mounting plates, dress the wires, and confirm wiring continuity before plugging in the speakers. In addition, a protective plastic cover prevents nicked wires by covering exposed speaker components. These devices also enable faster installations by providing instant feedback to ensure that wiring is properly connected, rotary switches to select voltage and power settings, and 7 field-selectable candela settings for both wall and ceiling speaker strobes. The low total harmonic distortion of the SP speaker offers high fidelity sound output while still offering high volume sound output for use in high ambient noise applications. L-Series makes installation easy • Attach a universal mounting plate to a 4 × 4 × 21/8 inch back box . Flush-mount applications do not require an extension ring. • Connect the notification appliance circuit or speaker wiring to the terminals on the mounting plate. • Attach the speaker or speaker strobe to the mounting plate by inserting the product tabs into the mounting plate grooves. Hinge the device into position to lock the product pins into the mounting plate terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw.Agency Listings 7320-1653:0505S4048FM approved except for ALERT models 3057493 28-3176 2.25 + 28-3176 2.26 L-Series Speaker and Speaker Strobe Specifications Architectural/Engineering Specifications General L-Series speaker and speaker strobes shall mount to a 4 × 4 × 21/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, L-Series speaker strobes, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32°F and 120°F from a regulated DC, or full-wave rectified, unfiltered power supply. Speaker strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, 177. Speaker The speaker shall be a System Sensor L-Series model _______ dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. It should be listed to UL 1480 and shall be approved for fire protective service. The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°F. The speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe combination The speaker strobe shall be a System Sensor L-Series model __________ listed to UL1480 and UL 1971 and be approved for fire protective signaling systems. The speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch, and shall have a frequency range of 400 to 4,000 Hz. The speaker shall have power taps that are selected by rotary switch. The strobe shall comply with the NFPA 72 requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz. The module shall mount to a 411/16 × 411/16 × 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical Specifications Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Dimensions, Ceiling-Mount Diameter Depth SPC Speaker 6.8 in, 173 mm 1.0 in, 25 mm With Surface Mount Back Box 6.9 in, 176 mm 3.5 in, 89 mm SPSC Speaker Strobe 6.8 in, 173 mm 2.8 in, 73 mm With Surface Mount Back Box 6.9 in, 176 mm 5.37 in, 136 mm *When using 12AWG, 14 AWG, or adding extra wires in the box, a deeper box or extension ring is recommended. Electrical/Operating Specifications Nominal Voltage (speakers)25 Volts or 70.7 Volts (nominal) Maximum Supervisory Voltage (speakers)50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage (strobes)Regulated 12 VDC or regulated 24 VDC/FWR 1,2 Operating Voltage Range (includes fire alarm panels with built in sync) 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage with MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Frequency Range 400 to 4,000 Hz3 Power ¼, ½, 1, 2 watts 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. Strobe products will operate at 12 V nominal only for 15 and 30 cd. 3. 520 Hz +/- 10% square wave tone capable with compatible FACP. AVDS866-03 • 03/23/2018 • Page 2 System Sensor copypaste shortcuts 7/8 11/16 1/8 ¼ UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) Candela 8 to 17.5 Volts 16 to 33 Volts DC DC FWR 15 87 41 60 30 153 63 86 75 NA 111 142 95 NA 134 164 115 NA 158 191 150 NA 189 228 177 NA 226 264 Ceiling-Mount Speaker Sound Output Setting UL Reverberant (dBA @10 ft) UL Anechoic (dBA @10 ft) 1/4 W 79 79 1/2 W 82 82 1 W 85 85 2 W 88 88 Ceiling-Mount Speaker Strobe Sound Output Setting UL Reverberant (dBA @10 ft) UL Anechoic (dBA @10 ft) 1/4 W 77 77 1/2 W 80 80 1 W 83 83 2 W 86 86 L-Series Dimensions Ceiling Speaker Ceiling Speaker Strobe AVDS866-03 • 03/23/2018 • Page 3 1.0" (25.4 mm) 1.63" (41.66 mm)6.8" dia. (173 mm) 1.63" (41.66 mm)6.8" dia. (173 mm) 2.87" (72.9 mm) 1.76" (44.7 mm) A0543-00 A0544-00 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2018 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS866-03 • 03/23/2018 L-Series Ordering Information Ceiling Mount White Red Description SPCWL SPCRL Speaker only SPSCWL SPSCRL Speaker Strobe SPSCWL-P —Plain, Speaker Strobe SPSCWL-SP —Fuego, Speaker Strobe SPSCWL-CLR-ALERT —Alert, Speaker Strobe, Clear Lens Accessories White Red Description SBBCWL SBBCRL Universal Ceiling Surface Mount Back Box TRC-2W TRC-2 Universal Ceiling Trim Ring Surface Mounting Ceiling Speaker with Surface Mount Back Box Ceiling Speaker Strobe with Surface Mount Back Box Ceiling Speaker Strobe with Trim Ring and 4" Square Electrical Box A0542-00 A0520-01 A0504-01 Agency Listings 7320-1653:0505S4048FM approved except for ALERT models 3057493 AVDS867-03 • 6/6/2019 • Page 1 Indoor Selectable- Output Speaker Strobes and Dual Voltage Evacuation Speakers for Wall Applications System Sensor L-Series selectable output speaker strobes and dual-voltage evacuation speakers can reduce ground faults and enable faster installation with lower current draw and modern aesthetics. Features •Plug-in design and protective cover reduce ground faults • Universal mounting plate with an onboard shorting spring tests wiring continuity before installation •No extension ring required • Field selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, 185 • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Rotary switch simplifies field selection of speaker voltage (25 and 70.7 Vrms) and power settings (¼, ½, 1 and 2 watts) •Speakers offer high fidelity and high volume sound output •520 Hz +/- 10% square wave tone capable with compatible FACP •Compatible with System Sensor synchronization protocol •Electrical compatibility with existing SpectrAlert and SpectrAlert Advance products •Tamper-resistant construction •Updated modern aesthetics The System Sensor L-Series of speakers and speaker strobes reduce costly ground faults using a plug-in design and universal mounting plate that allow the installer to pre-wire mounting plates, dress the wires, and confirm wiring continuity before plugging in the speakers. In addition, a protective plastic cover prevents nicked wires by covering exposed speaker components. These devices also enable faster installations by providing instant feedback to ensure that wiring is properly connected, rotary switches to select voltage and power settings, and 7 field-selectable candela settings for wall speaker strobes. The low total harmonic distortion of the speaker offers high fidelity sound output while still offering high volume sound output for use in high ambient noise applications. System Sensor L-Series makes installation easy • Attach a universal mounting plate to a 4 × 4 × 21/8 inch back box. Flush-mount applications do not require an extension ring. • Connect the notification appliance circuit or speaker wiring to the terminals on the mounting plate. • Attach the speaker or speaker strobe to the mounting plate by inserting the product tabs into the mounting plate grooves. Hinge the device into position to lock the product pins into the mounting plate terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. 28-3176 2.26 AVDS867-03 • 6/6/2019 • Page 2 L-Series Speaker and Speaker Strobe Specifications Architectural/Engineering Specifications General L-Series speaker and speaker strobes shall mount to a 4 × 4 × 21/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, L-Series speaker strobes, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32°F and 120°F from a regulated DC, or full-wave rectified, unfiltered power supply. Wall- mount speaker strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, 185. Speaker The speaker shall be aSp System Sensor L-Series model _______ dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. It should be listed to UL 1480 and shall be approved for fire protective service. The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°F. The speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe combination The speaker strobe shall be a System Sensor L-Series model __________ listed to UL1480 and UL 1971 and be approved for fire protective signaling systems. The speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch, and shall have a frequency range of 400 to 4,000 Hz. The speaker shall have power taps that are selected by rotary switch. The strobe shall comply with the NFPA 72 requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize strobes at 1 Hz. The module shall mount to a 411/16 × 411/16 × 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical Specifications Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Dimensions, Wall-Mount Length Width Depth SPL Speaker 6.5 in, 165 mm 5 in, 127 mm 0.97 in,23 mm With Surface Mount Back Box 6.6 in, 168 mm 5.1 in, 130 mm 3.2 in, 82 mm SPSL Speaker/Strobe (including lens and speaker) 6.5 in, 165 mm 5.0 in, 127 mm 2.3 in, 58 mm With Surface Mount Back Box 6.6 in, 168 mm 5.1 in, 130 mm 4.5 in, 116 mm *When using 12AWG, 14 AWG, or adding extra wires in the box, a deeper box or extension ring is recommended. Electrical/Operating Specifications Nominal Voltage (speakers)25 Volts or 70.7 Volts (nominal) Maximum Supervisory Voltage (speakers)50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage (strobes)Regulated 12 VDC or regulated 24 DC/FWR1,2 Operating Voltage Range (includes fire alarm panels with built in sync) 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage with MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Frequency Range 400 to 4000 Hz3 Power ¼, ½, 1, 2 watts 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. Strobe products will operate at 12 V nominal only for 15 and 30 cd 3. 520 Hz +/- 10% square wave tone capable with compatible FACP. AVDS867-03 • 6/6/2019 • Page 3 UL Current Draw Data UL Max Strobe Current Draw (mA RMS) Candela 8 to 17.5 Volts 16 to 33 Volts DC DC FWR 15 88 43 60 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 Sound Output Speaker Strobe ¼ W ½ W 1 W 2 W UL Reverberant (dBA @10 ft)77 80 83 86 UL Anechoic (dBA @10 ft)77 80 83 86 Sound Output Speaker ¼ W ½ W 1 W 2 W UL Reverberant (dBA @10 ft)79 82 85 88 UL Anechoic (dBA @10 ft)79 82 85 88 L-Series Dimensions Wall-Mount Speaker Wall-Mount Speaker Strobe 5" (127 mm) 0.97" (24.64 mm) 1.63" (41.66 mm) 6.5" (165 mm) 1.39" (35.31 mm) 6.5" (165 mm) 5" (127 mm) 1.63" (41.66 mm) 2.3" (58 mm) A0555-01 A0556-01 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2019 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS867-03 • 6/6/2019 L-Series Ordering Information Wall Mount White Red Description SPWL SPRL Speaker only SPSWL SPSRL Speaker Strobe SPSWL-P SPSRL-P Plain Speaker Strobe SPSWL-ALERT —Speaker Strobe, Amber Lens SPSWL-CLR-ALERT —Speaker Strobe Clear Lens —SPSRL-SP Speaker Strobe, Fuego Accessories White Red Description RFPW RFP 7 in × 9.5 in Retrofit Plate SBBSPWL SBBSPRL Surface Mount Back Box for Speakers and Speaker Strobes TR-2W TR-2 Wall Mount Trim Ring Notes: All -P models have a plain housing (no “FIRE” marking on the cover) Surface Mounting Wall-Mount Speaker Strobe with SBBSPRL/ SBBSPWL Surface Mount Back Box A0523-01 Agency Listings Outdoor, Selectable- Output Speaker Strobes and Dual- Voltage Evacuation Speakers for Wall Applications SpectrAlert® Advance outdoor, selectable-output speaker strobes and dual-voltage evacuation speakers meet virtually any outdoor application requirement. Features •Weatherproof per NEMA 4X, IP56 •Rated from -40°F to 151°F •Plug-in design reduces ground faults • Universal mounting plate with onboard shorting spring that tests wiring continuity before devices are installed • Field-selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Rotary switch for speaker voltage (25 and 70.7 Vrms) and power settings (1/4, 1/2, 1 and 2 watts) • Compatible with System Sensor synchronization protocol and legacy SpectrAlert products •Tamper-resistant construction •Listed for ceiling or wall mounting SpectrAlert Advance offers the broadest line of outdoor speakers and speaker strobes in the industry. From metal and plastic outdoor back boxes, to white and red plastic housings, to wall and ceiling mounting options, SpectrAlert Advance can meet virtually any application requirement. Wall-mount outdoor speakers and speaker strobes can be used indoors or outdoors in wet or dry applications, and can provide reliable operation from −40°F to 151°F. These speakers provide a broad frequency response range, low harmonic distortion and maintain a high sound pressure level at all tap settings to provide accurate and intelligible broadcast of evacuation messages. Like the entire SpectrAlert Advance line, wall-mount outdoor speakers and speaker strobes include a variety of features that increase application flexibility and simplify installation. First, field-selectable settings, including candela, speaker voltage and power settings, and automatic selection of 12- or 24-volt operation enable installers to easily adapt devices to meet requirements. Next, these devices use a universal mounting plate with an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in-and- out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock-outs located on the back eliminate the need to drill holes for screw-in mounting. Plastic and metal weatherproof back boxes come with ¾-inch top and bottom conduit entries and ¾-inch knock-outs at the back. A screw-in NPT plug with an O-ring gasket for a watertight seal is included with each back box.10-08-E7320-1653:20175S0 28-3176 2.26 AVDS11301 SpectrAlert® Advance Outdoor Speaker and Speaker Strobe Specifications Architectural/Engineering Specifications General SpectrAlert Advance outdoor speakers and speaker strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance speaker strobes, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Outdoor SpectrAlert Advance products shall operate between –40°F and 151°F from a regulated DC, or full-wave rectified, unfiltered power supply. Speaker Speaker shall be a System Sensor SpectrAlert Advance Model ______ dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. Speaker shall be listed to Underwriters Laboratories Standard S4048 for outdoor fire protective signaling systems. Speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature from –40°F to 150.8°F. Speaker shall have power taps and wattage settings that are selected by rotary switches. The speaker must be installed with its weatherproof back box in order to remain outdoor approved per UL listing S4048. The speaker shall be suitable for use in air handling spaces and wet environments. Speaker Strobe Combination The speaker strobe shall be a System Sensor Model _____ listed to UL 1638 and UL 1480 and be approved for fire protective signaling systems. Speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms and shall have a frequency range of 400 to 4,000 Hz. Speaker shall have power taps that are selected by rotary switch. The strobe shall consist of a xenon flash tube with associated lens/reflector system and operate on either 12 or 24 volts. The strobe shall also feature selectable candela output, providing options for 15 or 15/75 candela when operating on 12 volts and 15, 15/75, 30, 75, 110, 115, 135, 150, 177 or 185 candela when operating on 24 volts. The strobe shall comply with the Americans with Disabilities Act requirement for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The speaker strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The speaker strobe shall be suitable for use in wet environments. Physical Specifications Operating Temperature –40°F to 151°F (–40°C to 66°C) Dimensions, Wall-Mount SPS Speaker Strobe 6.0˝ L × 5.0˝ W × 4.7˝ D (including lens and speaker) SP Speaker 6.0˝ L × 5.0˝ W × 2.9˝ D Dimensions, Wall-Mount Weatherproof Back Box 6.5˝ L × 5.5˝ H × 2.9˝ D Electrical/Operating Specifications Nominal Voltage (speakers)25 V or 70.7 V (nominal) Maximum Supervisory Voltage (speakers)50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage (strobes)Regulated 12 VDC/FWR or regulated 24 DC/FWR Operating Voltage Range (includes fire alarm panels with built in sync) 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage with MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Frequency Range 400 to 4,000 Hz Power ¼, ½, 1, 2 watts AVDS11301 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) Candela 8 to 17.5 Volts 16 to 33 Volts DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High Candela Range 135 NA NA 228 207 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 Sound Output UL Reverberant (dBA @ 10 ft.)2W 1W ½ W ¼ W Outdoor Speaker 90 87 84 81 Outdoor Speaker/Strobe 89 86 83 80 Dimensions Candela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Strobe Output (cd) Listed Candela Candela rating at –40°F 15 Do not use below 32°F15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 5.00˝.97˝1.84˝ 5.98˝ 5.00˝2.83˝ 1.84˝1.60˝ 5.97˝ Wall-Mount Outdoor Speaker Wall-Mount Outdoor Speaker Strobe 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2012 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS11301 • 09/12 Ordering Information for SpectrAlert® Advance Outdoor Speakers and Speaker Strobes Wall Mount White Red Description SPWK SPRK Outdoor Speaker (includes plastic weatherproof back box) SPWK-R SPRK-R Outdoor Speaker (does not include plastic weatherproof back box) SPSWK SPSRK Outdoor Speaker Strobe, Standard cd (includes plastic weatherproof back box) SPSWK-P SPSRK-P Plain Outdoor Speaker Strobe, Standard cd(includes plastic weatherproof back box) SPSWK-R SPSRK-R Outdoor Speaker Strobe, Standard cd(does not include weatherproof back box) SPSWK-CLR-ALERT —Outdoor Speaker Strobe, Standard cd, Clear Lens, ALERT Printed (includes plastic weatherproof back box) —SPSRHK Outdoor Speaker Strobe, High cd (135,150,177,185) (includes plastic weatherproof back box) Accessories White Red Description MWBBW MWBB Wall, Metal Weatherproof Back Box Notes: All -P models have a plain housing (no “FIRE” marking on cover) “Standard cd” refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. “High cd” refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units, both the device and back box must be replaced. Surface Mounting Wall-Mount Speaker Strobe with Plastic Weatherproof Back Box Wall-Mount Speaker Strobe with Metal Weatherproof Back Box Wall-Mount Speaker with Plastic Weatherproof Back Box Wall-Mount Speaker with Metal Weatherproof Back Box WIRE GUARDS For more information, call 248-673-9898 or visit www.sti-usa.com. KEY FEAtURES General Information · Offers protection against vandalism and accidental damage. · Simple removal for maintenance. · For use in controlled environment (not intended for outdoor use). · three year guarantee against breakage in normal use. Construction · Constructed of tough 9-gauge steel wire. · Coated with corrosion resistant polyester. Installation · Installation is fast and simple with screws and anchors provided. Options ·StI-9705, StI-9708, StI-9711 and StI-9714 protect SpectrAlert® strobe units. ·StI-9717 and StI-9720 fit over System Sensor notification appliances P2R1224MC and SP2W1224MC. hORn/StRObE /SPEAKER DAMAGE StOPPERS® PRODUCt OvERvIEW here are excellent ways to protect strobe units against both vandalism and accidental damage. Constructed of tough, 9-gauge steel wire coated with corrosion resistant red or white polyester, these guards can take hard knocks in stride. StI-9705, StI-9708, StI-9711 and StI-9714 wire guards provide maximum protection for System Sensor SpectrAlert® Advance series strobe notification appliances. bACKED bY A thREE YEAR GUARAntEE As all StI protective covers, these guards are backed by a three year guarantee against breakage in normal use. Installation and servicing is easy with all screws and anchors provided. this Stopper is highly recommended for areas where abuse is severe or it is imperative that strobe units continue to operate. StI-9717 and StI-9720 fit over System Sensor notification appliances SP2R1224MC and SP2W1224MC. StI-9705-R StI-9711 StI-9720 28-3176 2.27 Printed in U.S.A., © 1987-2020 Safety technology International, Inc. 2306 Airport Road Waterford, Michigan 48327, USA Tel: 248-673-9898 Fax: 248-673-1246 info@sti-usa.com www.sti-usa.com Taylor House 34 Sherwood Road Bromsgrove, Worcestershire B60 3DR, England Tel: +44 (0)1527 520 999 Fax: +44 (0)1527 501 999 info@sti-emea.com www.sti-emea.com 03/20Subject to change without notice. APPROvAlS & WARRAnt Y TESTING StI-9705, StI-9708, StI-9711 and StI-9714 have been tested and approved or listed by: · Underwriter laboratories and Canadian Ul File S7025 WARRANTY three year guarantee against breakage in normal use. horn/Strobe/Speaker Damage Stoppers® Dimensions and technical Information MODElS AvAIl AblE STI-9705 Damage Stopper, Flush Mount - White STI-9705-R Damage Stopper, Flush Mount - Red STI-9708 Damage Stopper, Surface Mount - White STI-9708-R Damage Stopper, Surface Mount - Red STI-9711 Damage Stopper, Flush Mount - White STI-9714 Damage Stopper, Surface Mount - White STI-9717 Speaker/Strobe Damage Stopper - Flush Mount (not Ul listed) STI-9720 Speaker/Strobe Damage Stopper - Surface Mount (not Ul listed) MODEL HEIGHT WIDTH DEPTH StI-9705 StI-9705-R 7.40 in. (188mm) 6.15 in. (156mm) 3.39 in. (84mm) StI-9708 StI-9708-R 7.49 in. (190mm) 6.74 in. (171mm) 6.09 in. (155mm) StI-9711 8.26 in. (210mm) 8.26 in. (210mm) 3.54 in. (90mm) StI-9714 8.55 in. (271mm) 8.55 in. (271mm) 6.23 in. (158mm) StI-9717 6.1 in. (155mm) 9.3 in. (238mm) 2.4 in. (61mm) StI-9720 6.1 in. (155mm) 9.3 in. (238mm) 4.9 in. (125mm) Light De-Rating Factor STI-9705 and STI-9708 System Sensor (SR,SW, SW-AlERt, SW-ClR-AlERt, SRK, SWK, P2R, P2W, P4R, P4W, ChSR, ChSW, P2RK, P2WK, P4RK, P4WK, SPSR, SPSR-SP, SPSR-PG, SPSW, SPSW- ClR-AlERt, SPSW-SP, SPSW-PG, SPSRv, SPSRv-SP, SPSRv-PG, SPSW v, SPSW v-SP and SPSW v-PG, SPSWK, SPSRK, SPSW-AlERt ) System Sensor (SRh, SWh, SRhK, SWh-AlERt, SWhK, P2Rh, P2Wh, P4Rh, P2RhK, P2WhK, P2RhK-120, SPSRh, SPSRh-SP, SPSRh-PG, SPSWh, SPSWh-SP and SPSWh- PG, SPSRhK) STI-9711 and STI-9714 System Sensor (SCR, SCW, SCRK, SCWK, SCW-ClR- AlERt, PC2R, PC2W, PC4R, PC4W, PC2RK, PC2WK, PC4WK, SPSCWv, SPSCR, SPSCR-SP, SPSCR-PG, SPSCW, SPSCW-SP, SPSCW-PG, SPSCRv, SPSCRv- PG, SPSCW v, SPSCW v-SP and SPSCW v-PG, SPSCWK, SPSCW-ClR-AlERt) System Sensor (SCRh, SCWh, SCRhK, SCWhK, PC2Rh, PC2Wh, PC4Rh, PC2RhK, PC2WhK, PC4WhK, SPSCWhv, SPSCRh, SPSCRh-SP, SPSCRh-PG, SPSCWh, SPSCWh- SP, SPSCWh-PG, SPSCRvh, SPSCRvh-SP, SPSCRvh-PG, SPSCWhv-SP SPSCWhv-PG, SPSCWhK) Light Loss % 13% 0% 0% 0% STI-9705 ANCHOR (4) PROVIDED H19020 CLAMP (4) PROVIDED #10 x 1-1/2 in. PHILLIPS PAN HEAD SCREW (4) PROVIDED 7.40 in.(188mm) 3.39 in. (86mm) 6.15 in. (156mm) 6.74 in. (171mm) 7.49 in. (190mm) 6.09 in. (155mm) 3.1 in. (79mm) 3.15 in. (80mm) 1.63 in. (41mm) SPEAKER/STROBE MOUNTING PLATE STI-9705 WIRE GUARD SPEAKER/STROBE STI-1285 BACKPLATE 4” SQUARE ELECTRICAL BOX STI-9708 CEILING STROBE ANCHOR (4) PROVIDED #10 x 1-1/2 in. PHILLIPS PAN HEAD SCREW (4) PROVIDED H19020 CLAMP (4) PROVIDED STROBE AND BACKBOX 22.5° 3.54 in. (90mm) 8.26 in. (210mm) STI-9711 STI-9714 6.23 in. (158mm) 8.55 in. (271mm) CEILIING SPEAKER/STROBE 4” SQUARE ELECTRICAL BOX STI-1286 BACKPLATE CEILING SPEAKER/STROBE MOUNTING PLATEWIRE GUARD CLAMPS ANCHOR (4) PROVIDED H19020 CLAMP (4) PROVIDED #10 x 1-1/2 in. PHILLIPS PAN HEAD SCREW (4) PROVIDED 7.40 in.(188mm) 3.39 in. (86mm) 6.15 in. (156mm) 6.74 in. (171mm) 7.49 in. (190mm) 6.09 in. (155mm) 3.1 in. (79mm) 3.15 in. (80mm) 1.63 in. (41mm) SPEAKER/STROBE MOUNTING PLATE STI-9705 WIRE GUARD SPEAKER/STROBE STI-1285 BACKPLATE 4” SQUARE ELECTRICAL BOX CEILING STROBE ANCHOR (4) PROVIDED #10 x 1-1/2 in. PHILLIPS PAN HEAD SCREW (4) PROVIDED H19020 CLAMP (4) PROVIDED STROBE AND BACKBOX 22.5° 3.54 in. (90mm) 8.26 in. (210mm) STI-9711 STI-9714 6.23 in. (158mm) 8.55 in. (271mm) CEILIING SPEAKER/STROBE 4” SQUARE ELECTRICAL BOX STI-1286 BACKPLATE CEILING SPEAKER/STROBE MOUNTING PLATEWIRE GUARD CLAMPS CEILING STROBE ANCHOR (4) PROVIDED #10 x 1-1/2 in. PHILLIPS PAN HEAD SCREW (4) PROVIDED H19020 CLAMP (4) PROVIDED STROBE AND BACKBOX 22.5° 3.54 in. (90mm) 8.26 in. (210mm) STI-9711 STI-9714 6.23 in. (158mm) 8.55 in. (271mm) CEILIING SPEAKER/STROBE 4” SQUARE ELECTRICAL BOX STI-1286 BACKPLATE CEILING SPEAKER/STROBE MOUNTING PLATEWIRE GUARD CLAMPS STI-9711 EXISTING SYSTEM SENSOR WALL SPEAKER/STROBE SIGNAL DEVICE SHOWN WITH ACCESSORY BACK BOX SKIRT. STI-9720 SURFACE MOUNT STI-9717 FLUSH MOUNT PHILLIPS PAN HEAD SCREW #10 x 1 1/2 in. (4) PROVIDED H19020 CLAMP (4) PROVIDED ANCHOR (4) PROVIDED DRILL (4) .25 in.(6.3mm) HOLES EXISTING SYSTEM SENSOR WALL SPEAKER/STROBE SIGNAL DEVICE CLAMPS MAY BE INSTALLED VERTICALLY OR HORIZONTALLY AS SHOWN 3.7 in. (94mm)4.9 in. (125mm) STI-9720 TOP VIEW 1.2 in. (31mm)2.4 in. (61mm) STI-9717 TOP VIEW 9.3 in.(238mm) 6.1 in. (155mm) STI-9717 and STI-9720 FRONT VIEW STI-9717 SIDE VIEW FEATURES & BENEFITS •Single contact monitor •Support for Class A and Class B wiring •Fully supervised •Panel controlled status LED that flashes green in normal state and is solid red in alarm •SEMS screws for easy wiring •UL Listed •Rotary address switches for fast installation SK-MONITOR Intelligent Monitor Module The SK-MONITOR is an addressable monitor module for use with Honeywell Silent Knight Series fire alarm control panels (FACPs). The SK-MONITOR is intended for use in intelligent, two-wire systems, where individual address of each module is selected using the built-in rotary switches. The SK-MONITOR supports Class A supervised or Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions. INSTALLATION The SK-MONITOR mounts directly into a 4” square electrical box. The box must have a minimum depth of 2-1/8”. A surface mount electrical box (System Sensor® PN SMB500) is available from Silent Knight.SK-MONITOR 28-3176 2.29 For a complete listing of all compliance approvals and certifications, please visit www.silentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Silent Knight®, System Sensor® and Honeywell® are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 800-446-6444. SK-MONITOR Technical Specifications PHYSICAL Height: 4.5”H x 4” W x 1.25”D (11.4 X 10.2 X 3cm) Shipping Weight: 6.3 oz (196 g) ELECTRICAL Operating Voltage: 15 – 32VDC Current Draw (LED on): 5.0mA max Operating Current (LED flashing): 375 μ A Standby Current: 400 μ A max @ 24 VDC (one communication every 5 sec with 47K EOL); 550 μ A max @ 24 VDC (one communication every 5 sec with EOL <1K) 5.5 mA (with LED latched on) LED Current: 5.5 mA (with LED latched on) End-of-Line Resistance: 47K W Initiating Device Circuit Wiring Resistance: 1,500 W max SLC Loop Resistance: 40 W max. ENVIRONMENTAL Operating Temperature: 32ºF – 120ºF (0ºC – 49ºC) Humidity: 10% – 93% non-condensing ORDERING INFORMATION SK-MONITOR: Monitor Module ACCESSORIES. SMB500: 4” Square surface mount electrical box COMPATIBILITY The SK-MONITOR is compatible with the following Honeywell Silent Knight fire alarm control panels: 6820: Addressable fire alarm control panel 6820EVS: Addressable fire alarm control panel with an emergency mass notification system. 6808: Addressable fire alarm control panel 6700: Addressable fire alarm control panel 5700: Addressable fire alarm control panel 5808: Addressable fire alarm control panel 5820XL: Addressable fire alarm control panel 5820XL-EVS: Addressable fire alarm control panel with an emergency mass notification system Doc 350131 | Rev G | 11/17 © 2017 Honeywell International Inc. For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 FEATURES & BENEFITS •Two sets of Form C contacts •Rotary address switches for fast installation •Contacts are rated for a variety of amps (see Specifications) •Panel controlled status LED that flashes green in normal state and is solid red in alarm •Relay programming is completely flexible– can be mapped to zone conditions •Polling LED visible through the cover plate •SEMS screws for easy wiring •UL Listed SK-RELAY Intelligent Relay Module The SK-RELAY is an addressable relay module for use with Honeywell Silent Knight Series fire alarm control panels (FACPs). The SK-RELAY allows a Silent Knight FACP to switch discrete contacts by code command. The relay contains two isolated sets of Form C contacts, which operate as a DPDT switch. No supervision is provided for the notification appliance circuit. The SK-RELAY contacts can be used for virtually any normally open or normally closed application. Each SK-RELAY is programmed with a unique signaling line circuit (SLC) loop address. When an event occurs that controls the SK-RELAY, the relay is triggered by the FACP. INSTALLATION The SK-RELAY mounts directly into a 4” square electrical box. The box must have a minimum depth of 2-1/8”. A surface mount electrical box (System Sensor® PN SMB500) is available from Silent Knight. SK-RELAY 28-3176 2.30 For a complete listing of all compliance approvals and certifications, please visit www.silentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Silent Knight®, System Sensor® and Honeywell® are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 800-446-6444. SK-RELAY Technical Specifications PHYSICAL 4.675" H x 4.275" W x 1.4" D Shipping Weight: 6.3 oz (196 g) ELECTRICAL Operating Voltage: 15 – 32 VDC End-of-Line Resistance: Not used SLC Standby & Alarm Current: .255mA max @ 24VDC (one communication every 5 sec with LED enabled) ENVIRONMENTAL Operating Temperature: 32ºF – 120ºF (0ºC – 49ºC) Humidity: 10% – 93% non-condensing RELAY CONTACT RATINGS 3.0A @ 30VDC resistive 0.9A @ 110VDC resistive 0.9A @ 125VAC resistive 0.5A @ 125VAC inductive (PF = .35) 0.7A @ 75VAC inductive (PF = .35) ORDERING INFORMATION SK-RElAY: Relay Module ACCESSORIES. SMB500: 4” Square Surface Mount Electrical Box CB500 :Module Barrier COMPATIBILITY The SK-RELAY is compatible with the following Honeywell Silent Knight fire alarm control panels: 6820: Addressable fire alarm control panel 6820EVS: Addressable fire alarm control panel with an emergency mass notification system. 6808: Addressable fire alarm control panel 6700: Addressable fire alarm control panel 5700: Addressable fire alarm control panel 5808: Addressable fire alarm control panel 5820XL: Addressable fire alarm control panel 5820XL-EVS: Addressable fire alarm control panel with an emergency mass notification system. Doc 350127| Rev G| 11/17 © 2017 Honeywell International Inc. For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 Page 1 of 4 DATA SHEET K85001-0421 Not to be used for installation purposes. Issue 1 Kidde Catalog u Power Supplies and Accessories 10-11-16Technology that saves lives Overview Electromagnetic Door Holders are ruggedly constructed and attractively designed. The housing is finished with an aluminum color, durable baked polyester powder paint. The floor or wall sec- tion houses the electromagnet while the contact plate attaches to the door. The contact plate has a shock absorbing nylon (swivel) ball which allows the plate to adjust to any door angle. Floor units are available in single-door or double-door (back to back) versions. Wall units are available in flush or surface mounted versions. Door releases should be installed wherever doors may be effec- tively used to confine smoke and fire, or where the release of a self- closing door from a remote location is desirable for other reasons. Fail-safe operation is an inherent feature of Kidde door holder-re- leases. If power fails, doors are released automatically but may be opened or closed manually at any time. All units are free of moving parts, are self-contained and require no maintenance. These door holder-releases have a holding force of approximately 15 to 25 Lbf (66 to 111N). The device holds a door open while en- ergized. When de-energized by a relay controlled by the fire alarm system or other switch, the door is released to a closed position, checking the spread of smoke and flames. Electromagnetic door holders should be used and installed in accordance with local Building Codes and Standards. Standard Features •Floor and wall mounted styles •Low power consumption •AC/DC models •Completely silent operation •25 Lbf (111N) nominal holding force •Adjustable, swivel contact plate Basic Models Floor Mounted: The electromagnet portion consists of a floor plate and a floor housing which when installed with gaskets provided, form a weatherproof electrical junction box. Incoming conduit connects directly into floor plate. Floor mounted units are available with one (Cat. No. 1501) or two (Cat. No. 1502) magnet faces for holding a single door or two doors back to back. Wall Mounted: Wall mounted models are available in flush, semi-flush and surface mounting configurations. Flush and semi-flush models are de- signed for concealed wiring applications and mount on standard single gang (2 x 4 inch) outlet boxes. Surface mounted models mount on a surface adaptor housing (junction box), which is provided. Electromagnetic Door Holders R6291 28-3176 2.36 Page 2 of 4 DATA SHEET K85001-0421 Not to be used for installation purposes. Issue 1 Dimensions 1504-AQN5 Flush Wall Mounted (Long Catch Plate)1505-AQN5 Flush Wall Mounted (Short Catch Plate) 1501-AQN5 Floor Mounted (Single Door) 1502-AQN5 Floor Mounted (Double Door) 1508-AQN5 Surface Wall Mounted 1509-AQN5 Completely Flush Wall Mounted Catch Plate Extensions Only the extension rods are included. The end pieces are included with the doorholders or can be ordered separately. 1500-7 1500-12 1.5" (38 mm) 2.0" (50.8 mm) 3.125" (79.4 mm) 3.625" (92 mm) 4.125" (104.8 mm) 4.625" (117.5 mm) 2.342" (59.5 mm) 1.68" (47.7 mm) 8" max./6.37" min. (203.2 mm max./161.8 mm min.) 12" max./8.37" min. (304.8 mm max./212.6 mm min.) 1500-21500-1 1500-21500-1 1500-21500-1 1.5" (38 mm) 2.0" (50.8 mm) 3.125" (79.4 mm) 3.625" (92 mm) 4.125" (104.8 mm) 4.625" (117.5 mm) 2.342" (59.5 mm) 1.68" (47.7 mm) 8" max./6.37" min. (203.2 mm max./161.8 mm min.) 12" max./8.37" min. (304.8 mm max./212.6 mm min.) Page 3 of 4 DATA SHEET K85001-0421 Not to be used for installation purposes. Issue 1 Specifications Ordering Information CAUTION: These Door Holder units will not operate without electrical power. Model No.Style Volts Amps* 1501-AQN5 Floor Mounted (Single Door) 24 Vac 60 Hz 24 Vdc 120 Vac 60 Hz .015 1502-AQN5 Floor Mounted (Double Door) 1504-AQN5 Flush Wall Mounted (Long Catch Plate) 1505-AQN5 Flush Wall Mounted (Short Catch Plate) 1508-AQN5 Surface Wall Mounted 1509-AQN5 Completely Flush Wall Mounted *1502-AQN5 is a double unit which draws .015 per side Model No.Description Ship. Wt. lb (kg) 1501-AQN5 Floor Mounted (Single Door)5.4 (2.45) 1502-AQN5 Floor Mounted (Double Door)5.0 (2.27) 1504-AQN5 Flush Wall Mounted (Long Catch Plate)2.0 (0.91) 1505-AQN5 Flush Wall Mounted (Short Catch Plate)2.0 (0.91) 1508-AQN5 Surface Wall Mounted 3.0 (1.36) 1509-AQN5 Completely Flush Wall Mounted 2.0 (0.91) Accessories 1500-1 Catch plate extension assembly, 1.5”0.25 (0.11) 1500-2 Catch plate extension assembly, 2.5”0.25 (0.11) 1500-7 Catch plate extension assembly (5.25 to 7.5 inches)0.5 (0.23) 1500-12 Catch plate extension assembly (7.5 to 12 inches)1.0 (0.45) CS2595-5 Replacement armature - short (for use with 1501, 1502, 1505, 1508 and 1509 door holders)0.25 (0.11) CS2598-5 Replacement armature - long (for use with 1504 door holder)0.25 (0.11) Page 4 of 4 DATA SHEET K85001-0421 Not to be used for installation purposes. Issue 1 10-11-16Technology that saves lives Contact us... Email: kidde.fire@fs.utc.com Web: Kidde.com/EngineeredSystems Kidde is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. aes-corp.com 7707 Fire Subscribers www.aes-corp.com Feature Highlights •Leverages state of the art technology•Applies advanced security protection•Offers flexible power and configuration options•Engineered for backward compatibility with legacy systems•Enables future ready capabilities•Provides instant subscriber status through front panel with Power and Trouble LEDs, a backlit LCD display, and Menu/Silence button•Includes robust Multiple Communication Technologies (MCT) feature•Emulates virtual keypad•Improves functionality with an adaptive Graphic User Interface (GUI) for programming via smartphones, tablets and PCs•Plus many more… Key Benefits •Built upon the solid foundation of AES-IntelliNet patented mesh radio technology for use in private licensed wireless networks•Protects subscriber units against unauthorized access and rogue activity with a password-protected Dealer Code•Makes programming and streamlined troubleshooting easy with user friendly interface•Adds integrated supervision of AES-IntelliPro full data module•Provides versatile power options: (1) Direct from the Fire Alarm Control Panel (FACP) without requiring an electrician onsite and without Subscriber backup battery; (2) Directly from the FACP with Subscriber backup battery; or (3) Traditional installation with plug in Class 2 low power transformer•Allows for enhancement upgrades and an expanded number of new features to be added easily with highly flexible and scalable alarm communications infrastructure•Rigorously tested to the highest industry standards and future ready to meet emerging NFPA code and UL standards A Newer, Smarter Alarm Communications Platform 28-3176 2.40 Enhanced Wireless Fire Alarm Monitoring Powered by AES enhanced mesh radio technology, IntelliNet 2.0 7707 Fire Subscribers are next generation universal wireless communicators that provide advanced security protection for any new or existing alarm monitoring network. The AES Model 7707 is ideal for commercial fire applications. With the AES-IntelliPro full data module option, they are the ideal drop-in replacement for Plain Old Telephone Service (POTS) lines. The red metal enclosure comes with a key lock and front panel LCD backlit display with intuitive view that provides an instant visual of the subscriber status. The user friendly GUI makes it easy to program AES subscriber units via a smartphone, laptop, tablet, or integrated Universal Serial Bus (USB)—without the need for special cables or having to use a handheld programmer. Additional knockouts make it easier to mount for faster installation. IntelliNet 2.0 Private Wireless Mesh Radio Network The IntelliNet 2.0 Fire Subscriber has an 8 Zone modular design for expansion with normal and reverse polarity, POTS and DACT interfaces with an option for the 7794A AES-IntelliPro full data module add-on accessory board. AES subscribers’ intelligent software automatically detects new hardware and devices to reduce installation time. An AES certified WiFi accessory allows seamless wireless connectivity for configuration and programming. A laptop, Ethernet cable, or a Wi-Fi USB dongle is required for IntelliNet 2.0 programming, handheld programmers will not work with 2.0 units. A FACP Power Supply Adapter is required for certain configurations when using flexible power options. The forward compatible design allows for feature add-ons, engineered to adapt seamlessly with future software upgrades as technology advances. IntelliNet 2.0 allows configuration cloning for faster installation time. The AES 7707 was designed with quick configuration and installation in mind to make it easier for field technicians to get in, out, and on to the next install. Visit our Fire Marshal Resources web page for official NFPA and UL Listings: aes-corp.com/products/fire/fire-marshal-resources www.aes-corp.com How to Order 7707 Fire www.aes-corp.com IntelliNet 2.0 Fire Subscribers 2.0 PREMIUM (UL & ULC Listed) 7707P-88-M IntelliNet 2.0 Fire Subscriber, 8 Zone with Multiple Communication Technologies (MCT), Red Enclosure 7707P-88-ULP-M IntelliNet 2.0 Fire Subscriber, 8 Zone with 7794A AES-IntelliPro, and integrated onboard Local Annunciator plus MCT, Red Enclosure 7707P-44-M IntelliNet 2.0 Fire Subscriber, 4x4 Zone (4 Reversing Polarity, 4 Supervised) with Multiple Communication Technologies (MCT), Red Enclosure 7707P-44-ULP-M IntelliNet 2.0 Fire Subscriber, 4x4 Zone (4 Reversing Polarity, 4 Supervised) with 7794A AES-IntelliPro, and integrated onboard Local Annunciator plus MCT, Red Enclosure 2.0 ACCESSORIES 7794A Standalone AES-IntelliPro Fire full data module add-on accessory board with firmware for new IntelliNet 2.0 units only, cannot be used in legacy units 77-WiFi AES certified WiFi adapter 77-FACPA FACP Power Supply Adapter for internal mount 77-FACPA-KIT External installation hardware for 2-way Junction Box Legacy Fire Subscribers 7706-ULF Integrated Fire Monitoring System, Red Enclosure 7788F-ULP-P Legacy Fire Subscriber, 8 Zone with 7795 AES-IntelliPro (7794 full data module, 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure 7788F-ULP Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones with 7794 AES-IntelliPro, Red Enclosure 7788F Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones, Red Enclosure 7744F-ULP-P Legacy Fire Subscriber, 4 Zone with 7795 AES-IntelliPro (7794 full data module, 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure 7744F-ULP Legacy Fire Subscriber, 4x4 Zone, 4 Supervised Zones with 7794 AES-IntelliPro, Red Enclosure 7744F Legacy Fire Subscriber, 4x4 Zone, 4 Reversing Polarity, 4 Supervised Zones, Red Enclosure LEGACY ACCESSORIES 7794 Standalone AES-IntelliPro Fire full data module add-on accessory board for legacy units only, please see 7794A above for IntelliNet 2.0 version www.aes-corp.com AES Corporation | 285 Newbury Street | Peabody, MA 01960 United States © Copyright 2018 AES Corporation and AES-IntelliNet® are registered trademarks of AES Corporation 7707_03222018_F DIMENSIONS 13”H x 8.5”W x 4.5”D (33cmH x 21.5cmW x 11.4cmD) WEIGHT 5.8 lbs (2.6 kilograms) excluding battery 13 lbs (5.9 kilograms) with 10 Ah battery RADIO FREQUENCY Standard Frequency Range: 450-470 MHz Contact AES for other UHF and VHF frequencies ANTENNA 2.5 dB tamper resistant antenna included, mounts on enclosure Optional remote mounting antenna available POWER INPUT AC SOURCES Transformer: Class 2 16.5V AC nominal output 1.9 A max current (40 VA MIN) ELK ELK-TRG1640, MG ELECTRONIC SALES MGT1640, or AES 1640 (not included) DC SOURCES (includes FACP) 24V DC Regulated Power Supply with Subscriber Rechargeable Battery 1.9 A max current BACKUP BATTERY 10-12 Ah, UL recognized lead acid gel cell, size based on subscriber configuration PORTS Ethernet for configuration and message communication USB access for software upgrade REMOTE ANNUNCIATOR AES Model 7740 Remote Annunciator, supervised COMPATIBLE RECEIVERS 7705i AES-MultiNet Receiver CONFIGURATION INTERFACE Web browser capable device accessible via smartphone, tablet, laptop, or PC CURRENT CONSUMPTION Standby w/ charged backup battery: 200 mA (1.2 A Transmitting) Standby + charging backup battery: 900 mA (1.9 A Transmitting - MAX) POWER OUTPUT 2 or 5 Watts Factory set ENCLOSURE MATERIAL Steel with paint finish FINISH COLOR Red VISUAL INDICATORS Front panel LCD (2 x 20 alphanumeric character backlit display) Power and Trouble LEDs (ALM, Trouble, Tx, Rx, WA) ALARM SIGNAL INPUTS/ZONES · 8 individually programmable E.O.L. type zone inputs · 4+4: 4 reverse polarity input and 4 individually programmable E.O.L. type zone inputs · Optional 7794A AES-IntelliPro for full data via Contact ID, Pulse, Modem IIe and Modem IIIa2 UL LISTINGS UL 864 10th Edition Standard for Control Units and Accessories for Fire Alarm Systems ULC S559-04 1st Edition Equipment for Fire Signal Receiving Centres and Systems TROUBLE OUTPUT—ACK DELAY/ANTENNA CUT Form C relay, fail secure, rated 24V DC 1A resistive, unsupervised RESET BUTTON Located on main circuit board OPERATING TEMPERATURE 32 to 120°F (0 to 49°C) STORAGE TEMPERATURE 14 to 140°F (-10 to 60°C) RELATIVE HUMIDITY 0 to 93%, non-condensing RECHARGE CAPABILITY Will charge 12V battery size from 10-12 Ah Technical Specifications 7707 Fire Contact Us For pricing and availability or to learn more about IntelliNet 2.0, please call your local AES Sales Representative at (800) 237-6387 or email sales@aes-corp.com.