Loading...
2021.0030.SF0005 YCE Lot 5 Plan 1876-2 StampedThese plans are copyrighted inaccordance with federal statutes.Payment of use fee is due LevelDesign, LLC prior to constructionfor each structure built fromthese plans. Reproduction byany method of all, part orvariations thereof without writtenpermission from Level Design,LLC is expressly prohibited.These drawings and all printstherefrom remain the property ofLevel Design, LLC14611 S Yakima Ave. Tacoma, WA 98405PHONE: 253.284.3170FAX: 253.284.3183Leveldesign, llc.PLAN 1876-2RAINIER CAPITAL GROUP LLCYELM CREEK ESTATESPN# 85820000500LOT 5 42These plans are copyrighted inaccordance with federal statutes.Payment of use fee is due LevelDesign, LLC prior to constructionfor each structure built fromthese plans. Reproduction byany method of all, part orvariations thereof without writtenpermission from Level Design,LLC is expressly prohibited.These drawings and all printstherefrom remain the property ofLevel Design, LLC611 S Yakima Ave. Tacoma, WA 98405PHONE: 253.284.3170FAX: 253.284.3183Leveldesign, llc.MAIN FLOOR PLANSCALE: 1/4" =1'-0"c 2020 Level Design, LLC.UPPER FLOOR PLANSCALE: 1/4" =1'-0"c 2020 Level Design, LLC.PLAN 1876-2VENTILATION SCHEDULESMOKE DETECTORSCARBON MONOXIDE ALARMSAREA SUMMARYNOTE:CONTRACTOR TO VERIFY ALL DIMENSIONS AND CONDITIONS OFPROJECT AND REPORT ANY OMISSIONS/ DISCREPANCIES TODESIGNER PRIOR TO COMMENCING WORK. DESIGNER SHALL NOTBE RESPONSIBLE FOR DISCREPANT CONDITIONS RESULTING FROMUNAUTHORIZED WORK PERFORMED BY THE CONTRACTOR.* NO FIELD ALTERATIONS WILL BE AUTHORIZED UNLESS ACCOMPANIED BY REVISED DRAWINGS.NOTE:REFER TO STRUCTURAL SHEETS FOR SHEAR WALLSCHEDULE AND ENGINEERING PLAN WHICHCONTAIN DETAIL REFERENCES AND/ORINSTRUCTIONS PERTAINING TO EACH SHEAR WALLINDICATED IN THIS PLAN. 34These plans are copyrighted inaccordance with federal statutes.Payment of use fee is due LevelDesign, LLC prior to constructionfor each structure built fromthese plans. Reproduction byany method of all, part orvariations thereof without writtenpermission from Level Design,LLC is expressly prohibited.These drawings and all printstherefrom remain the property ofLevel Design, LLC611 S Yakima Ave. Tacoma, WA 98405PHONE: 253.284.3170FAX: 253.284.3183Leveldesign, llc.NOTE:CONTRACTOR TO VERIFY ALL DIMENSIONS AND CONDITIONS OFPROJECT AND REPORT ANY OMISSIONS/ DISCREPANCIES TODESIGNER PRIOR TO COMMENCING WORK. DESIGNER SHALL NOTBE RESPONSIBLE FOR DISCREPANT CONDITIONS RESULTING FROMUNAUTHORIZED WORK PERFORMED BY THE CONTRACTOR.* NO FIELD ALTERATIONS WILL BE AUTHORIZED UNLESS ACCOMPANIED BY REVISED DRAWINGS.NOTE:REFER TO STRUCTURAL SHEETS FOR SHEAR WALLSCHEDULE AND ENGINEERING PLAN WHICHCONTAIN DETAIL REFERENCES AND/ORINSTRUCTIONS PERTAINING TO EACH SHEAR WALLINDICATED IN THIS PLAN.SECTION "A"TYPICAL ROOF CONSTRUCTIONTYPICAL WALL CONSTRUCTIONTYPICAL FLOOR CONSTRUCTIONc 2020 Level Design, LLC.SCALE: 1/4" =1'-0"PLAN 1876-2 44These plans are copyrighted inaccordance with federal statutes.Payment of use fee is due LevelDesign, LLC prior to constructionfor each structure built fromthese plans. Reproduction byany method of all, part orvariations thereof without writtenpermission from Level Design,LLC is expressly prohibited.These drawings and all printstherefrom remain the property ofLevel Design, LLCLEFT ELEVATIONFRONT ELEVATIONREAR ELEVATIONRIGHT ELEVATIONSCALE: 1/4" =1'-0"SCALE: 1/4" =1'-0"SCALE: 1/4" =1'-0"SCALE: 1/4" =1'-0"c 2020 Level Design, LLC.NOTE:CONTRACTOR TO VERIFY ALL DIMENSIONS AND CONDITIONS OFPROJECT AND REPORT ANY OMISSIONS/ DISCREPANCIES TODESIGNER PRIOR TO COMMENCING WORK. DESIGNER SHALL NOTBE RESPONSIBLE FOR DISCREPANT CONDITIONS RESULTING FROMUNAUTHORIZED WORK PERFORMED BY THE CONTRACTOR.* NO FIELD ALTERATIONS WILL BE AUTHORIZED UNLESS ACCOMPANIED BY REVISED DRAWINGS.NOTE:REFER TO STRUCTURAL SHEETS FOR SHEAR WALLSCHEDULE AND ENGINEERING PLAN WHICHCONTAIN DETAIL REFERENCES AND/ORINSTRUCTIONS PERTAINING TO EACH SHEAR WALLINDICATED IN THIS PLAN.611 S Yakima Ave. Tacoma, WA 98405PHONE: 253.284.3170FAX: 253.284.3183Leveldesign, llc.PLAN 1876-2 FOUNDATION/ FRAMING PLANSCALE: 1/4" =1'-0"FOUNDATION VENTILATIONFOOTING SCHEDULE12/15/2020 TYPICAL SHEARWALL NOTESSHEAR WALL NOTESSHEAR WALLSMARK CALLOUTTYPICAL SHEARWALL NOTESSHEAR WALL SCHEDULESHEAR WALL KEY PLANMAIN FLOOR PLANUPPER FLOOR PLANTYPICAL HOLDDOWN NOTESHOLD DOWN TABLE*HOLD DOWN SCHEDULETYPEDESCRIPTIONFLOOR TO FLOOR STRAP12/15/2020 UPPER FLOOR FRAMING PLANSCALE: 1/4" =1'-0"””12/15/2020 ROOF FRAMING PLANSCALE: 1/4" =1'-0"12/15/2020 12/15/2020