Loading...
2021.0009 16404 Engineering2015 IBC LATERAL ANALYSIS AND GRAVITY LOAD ENGINEERING PROJECT NUMBER: 200691 FOR: ABN CONTRACTORS PLAN: YELM SITE CRITERIA SIMPSON PRODUCT DESIGN WIND WIND (IBC) SEISMIC SITE SOIL RISK SLOPE SPECIAL SITE GEOTECH FROST SEISMIC SEISMIC APPROX. ROOF SNOW SPEED EXPOSURE DESIGN CLASS. CATEGORY PER CONDITIONS REPORT PER DEPTH SPECTRAL SPECTRAL ELEVATION LOAD (V -ULT) 55Ix30' U.N.O. CATEGORY ® 12K CAPACITY OWNER PER OWNER OWNER (3(o)-5DS)/4'x 2�' TO 6x(o MIN. RESPONSE S1 RESPONSE SS 25 PSF 110 MPH B D D II <15% NONE NONE 12" 0.496g 1.2489 350 FT VALUES OBTAINED FROM JURISDICTION, STATE, AND NATIONAL AGENCIES HOLDOWN SCHEDULE SIMPSON PRODUCT FASTENERS POST TO FOOTING CONNECTION MODEL NUMBER 20"DIA. OR 24'DIA. x 8' ANCHOR BOLTS NAILS SCREWS CAPACITY* HDU5 - HF MEMBER 4340* N/A (14)-6DSY4'x 2�' TO (2) STUDS 65 5/844 URO. HDU5 - DF MEMBER 5645" MIN. HDU8 - HF MEMBER 58200 N/A (20)-SDSYa x 2l2' TO (2) STUDS 5ST525 OR SB 7/8'x24 HDU8 - DF MEMBER 7870* ® MIN. URO. HDUII - HF MEMBER 8030* N/A (30)-5D5Y4'x22- TO 6x6 MIN. 55Ix30' U.N.O. HDUII - DF MEMBER 9335* ® 12K CAPACITY HDU14 - HF MEMBER 9260" N/A (3(o)-5DS)/4'x 2�' TO 6x(o MIN. 551x30' URO. HDU14 - DF MEMBER 14445* 16SK CAPACITY 5THD14/5THDI4R) - 3500* (2) STUDS W/ (30) Ibd N/A N/A M5TC4853 - 3900' PER MFR N/A N/A MSTC6653 - 4490O PER MFR N/A N/A C514 - 2490" (18) 8d EACH SIDE N/A N/A HOLDOWN NOTES: (U INSTALL ALL SHEAR ANCHORS PER MANUFACTURER INSTRUCTIONS (2) ALL METAL CONNECTORS COMIW3 IN CONTACT WITH PRESSURE TREATED WOOD SHALL BE SIMPSON 'Z -MAX', TRIPLE ZINC COATED, OR HOT DIPPED GALVANIZED FOR CORROSION PROTECTION. (3) SUBSTITUTION WITH NON-SIMPSON ANCHORS WITH ENGINEER'S APPROVAL. �T LOCATIONS ONLY (RJ=RIM JOIST) W/ S" STEM W/ 8" STEM ( IRC 6023) STUDS SHALL BE CONTINUOUS FROM 50LE PLATE TO TOP PLATE 7 A m. 1 d-m� DO NOT 5C,4LE(1/4" =1' ) ENSURE VENTS ARE NOT AT HOLDOWN OR POINT LOAD LOCATION5 (TYF) o iii S10= \ ,�FA DO NOT 5C,4LE(1/4" =1') BLOCKING RESTRAINT AT J015T END 4 EACH INTERMEDIATE SUPPORT (5E15MIC ZONE D 8502.1) PROVIDE ALL FINAL SHOP DRAWINGS TO HODGE ENGINEERING 45 SOON A5 COMPLETED. IF DESIGNER'S DRAWINGS DIFFER 5TRUCTURALLY FROM SHOPS ADDITIONAL ENGINEERING WILL BE REQUIRED. INSTALL AND BRACE J015T6 AND TRUSSES PER MANUFACTURER RX 1.0 6.0 2.0 3.0 <8 Df*2 3-1/2'x12' GLB RX =2x4 ■=(2)2x4 i ■=(3)2x4 .=(4)2x4 W D�Sul(5U11 14 HDU5 We C614 1 FOOTING PAD SCHEDULE FOR 1500 PSF SOIL BEARING POSITIVE POST TO FOOTING CONNECTION 20"DIA. OR 24'DIA. x 8' O20oR24 ® POST PER PLAN 215K CAPACITY OR 4.0K CAPACITY 24 24"x24"x8' U)/(2) *4 E.W. 5.5K CAPACITY POST PER PLAN 30 30'x30'x10' W/(4) *4 E.W. ® 6.5K CAPACITY POST PER PLAN 36 36'x36 "x12' W/(4) *4 E.W. ® 12K CAPACITY POST PER PLAN 42 42"x42'xl2' W/(5) *4 E.W. 16SK CAPACITY POST PER PLAN 12 60 54 4648'x48'x12' *4 UJ/(6) E.W. 21K CAPACITY POST PER PLAN (54' x13" WK -7) *4 CAP = 2-1K) (60'x14" UJ/(8) *4 CAP = 33K) (12'x16' WKII) *4 CAP = 4ZK) ALL EXPANDED FOOTINGS TO USE *4 REBAR UNO. o POSITIVE POST TO FOOTING CONNECTION PER PLAN eREBAR q.'Ak MAT PER FOOTING SCI-IEDULE 3' FROM SOIL'SSIDES # BOTTOM 50U,45H BLOCKING O STUDS) FOR POINT LOAD FROM ABOVE O SQUASH BLOCKS) REQUIRED UNDER ALL DBL STUD OR GREATER WHERE INDICATED ON ENGINEERING. Digitally signed by John Hodge Date: 2021.01.25 17:00:33 -08'00' U) � in a m 3 �i r 3 0 r>�ncsa r, - r -I PCi� - r -I - r -I i� a) BUILDING CODE 2015 IBC WIND EXP. B 110 MPH SEISMIC DESIGN CATEGORY D E =L:j ENG. P.E. JOHN H. DATE 1.21.2021 REVIEW ZACK C. ANALYST ALEC H. SHEET S1 1 OF 5 SHEETS PROJECT NUMBER 200691 COPYRIG44T c@2020 1-IODGaE ENGINEERING INC. BEEN DIGITALLY SIGNED PER WAC 196 -23 -MO WITH A GLOBAL SIGN CERTIFICATE. THE CERTIFICATE MAY 5E REMOVED BY Tl$ JURISDICTION 2015 IBC LATERAL ANALYSIS AND GRAVITY LOAD ENGINEERING PROJECT NUMBER: 200691 FOR: ABN CONTRACTORS PLAN: YELM SITE CRITERIA 5HEAIR WALL NAILING 4 ANCHOR 5CHEDULE DESIGN WIND WIND (IBC) SEISMIC SITE SOIL RISK SLOPE SPECIAL SITE GEOTECH FROST SEISMIC SEISMIC APPROX. ROOF SNOW SPEED EXPOSURE DESIGN CLASS. CATEGORY PER CONDITIONS REPORT PER DEPTH SPECTRAL SPECTRAL ELEVATION LOAD (V -ULA I -2x6 I=(2)2x6 CATEGORY ® =6x6 EDGES OWNER PER OWNER OWNER JOIST RESPONSE S1 RESPONSE Ss (WF X.(33) 25 PSF 110 MPH B D D II <15% NONE NONE 12" 0.4968 1.2488 350 FT VALUES OBTAINED FROM JURISDICTION, STATE, AND NATIONAL AGENCIES r16-"� D2 EXTEND HEADER OVER PORTAL FRAME PER DETAIL 5/DI STWDI4 1":�IAIN f=LOOfR LATEfRAL ENGINEEfRING, DO NOT 5CY4LEN/a 11 =1' SNEAtN ALL EXTERIOR WALLS AS W1 UNLESS NOTED OTHERWISE. ADJUST CRAWL SPACE VENTS t0 BE 12' MINIMUM AWAY FROM HOEDOWNS 3'o.c. NAILING -CON?INUOUS 5HEATHING OVER MUD SILL TYPICAL ALL EXTERIOR WALLS TRUSS FASTENER 5CHEDULE: A35 m 32' cc OR 5DWC 6 a 16" OC. (TYPICAL AT ALL GABLE ENDS) HI -TYPICAL AT ALL TRUSS TO PERPENDICULAR TOP PLATE LOCA"""" (U.N.O.) (2)H2.5e - TYPICAL AT ALL MULTIPL, TRUSS TO PERPENDICULAR TOP PL LOCATIONS (U.N.O.) (LXMXR) DENOTES LEFT, MIDDLE TRUSS BEARING. REFER TO BUILDEF PROVIDED TRUSS MFR PROFILES FC ADDITIONAL INFORMATION. EXTEND HEADER OVER PORTAL FRAME PER DETAIL 50I Uf=f=EEfR f=LOOfR LATEfRAL ENGINEEfRING_ DO NOT 5CALEN/a 1'J SHEATH ALL EXTERIOR WALLS AS CJUJI UNLESS NOTED OTHERWISE. VAIL 5HEATHING TO ALL AMINCs MEMBERS U51NG Sd W/ 3' GRID PATTEN. NsraLL 5IMP50N L5TA STRAP 9 BACKSIDE ROWS 1(od SINKER 9 3'O.C. (IRC 602.3) STUDS SHALL BE CONTINUOUS FROM 50LE PLATE TO TOP PLATE ENGINEERED U51NG BUILDER PROVIDED MFR TRUSS LAYOUT COMPLETED BY THE TRU55 COMPANY(SLIMNER) JOB NUMBER J1010211, DATED 12212020. CHANGING TRUSSES INVALIDATES THIS ENGINEERING WHEN RAISED HEEL TRUSS ]ROOF 5HEATHING 5CHEDULE 5HEAIR WALL NAILING 4 ANCHOR 5CHEDULE SNOW LOAD NOMINAL SPAN RATING SHEAR WALL APA RATED NAIL 512E 4 STUD 4 BLOCKING tv SHEATHING 2x 50TTOM DSL TOP D5L TOP PLATE TO ANCHOR BOLT CAPACITY(PLF) SEISMIC/WIND (UP TO) THICKNESS MIN. LABEL SHEATHING SPACE m ADJOINING TO MUD SILL PLATE TOPLATE TO RIM 51RD TO CONCRETE (DF VALUES) N/A ® =44 DESIGNATOR 0 =4x6 I -2x6 I=(2)2x6 a =2x4 ■=(2)2x4 ® =6x6 EDGES EDGES NAILING RIM BELOW JOIST BLOCKING BELOW (WF X.(33) 5HEARWALL DESIGNATOR SEE SHEARWALL SGNEDULE 40 PSF 1/16' 24/16LTP4 M5TC4853 - 39000 1/1(01055 HOLDOWN/STRAP N/A 2x SILL W/ DESIGNATOR 6 18' O.C. (2) 10d 5/8 � 48 O.C. (16) ad EACH SIDE WDU5 N/A (2aC514s SW1 ONE EIDE � �, 6 ' O.C. 2x STUD ad � 3 O.C. 16d 6 6' O.C. OR TOENAILS 1/2 � 36 O.C. 260/365 D1 ,435 � 20' O.C. 1/16' 055 3x STUD 2x SILL W/LTP4 0 12' O.C. (2)10d 5/8' -9 40' 10 P5F 15/32111/211 32/16 Sun ONE SIDE ad s 4' O.C. (OR (2) 2x) ad 6 3' O.C. 16d .9 4' O.C. OR ,435 a 14 O.C. TOENAILS 1/2' 6 28' O.C. 380/532 1/16' 055 3x STUD 2x SILL W/ (2) ROWS 16d LTP4 -9 10' O.C. (2)10d 5/8' -1 24' O.C. 130 PSF 19/32', 5/8' 40/20 SW3 ONE 51DE ad � 3 O.C. (OR (2) 2x) ad a 3' O.C. 11 6' O.C. OR, TOENAILS 1/2',s 11' O.C. 490/685 A35 � 12 O.C. 115 PSF 23/321,3/41 48/24 AEON 1/16' 0553x 51DE ad tv 2 O.C. STUD (OR (2) 2x) 2x SILL W/ ad a 3' O.C. (2) ROWS 16d a 4' O.C. LTP4 0 1' O.C. OR, (2)10d TOENAILS 5/8' tv 21' O.C. 1/2' -9 15' O.C. 640/895 A35 .9 8 O.C. LONG DIMENSIONS PERPENDICULAR TO ROOF= LTP4 � 5' O.C. JOIST WITH EDGE SUPPORT. 1116' 055ad 0 3 O.C. 3x STUD 2x SILL W/ (2) ROWS 16d OR, (2)10d 5/8' 0 12' O.C. 980/1310 R503.211(l)SW5 50TH 51DES (OR (2) 2x) Sd .9 3' O.C. 11 3' O.C. A35 -95 O.C. TOENAILS 1/2' tv S' O.C. SHEAR WALL NOTES: (1) INSTALL PANELS VERTICALLY (2) WHERE SHEATHING 15 APPLIED ON BOTH SIDES OF WALL, PANEL EDGE JOINTS ON 2X FRAMING SHALL BE STAGGERED 50 JOINTS ON THE OPP051TE SIDES ,ARE NOT LOCATED ON THE SAME 5TUD5. (3) BLOCKING 15 REQUIRED AT ALL PANEL EDGES. (4) PROVIDE SHEAR WALL SHEATHING ,AND NAILING FOR THE ENTIRE LENGTH OF THE WALLS INDICATED ON THE PLANS. ENDS OF FULL HEIGHT WALLS ARE DESIGNATED BY EXTERIOR OF THE BUILDING, CORRIDORS, WINDOWS, OR DOORWAYS OR AS DESIGNATED ON THE PLANS. SEE PLANS FOR HOLDOWN REQUIREMENTS. (5) SHEATHING EDGE NAILING 15 REQUIRED AT ALL HOLDOWN POSTS. ((o) INTERMEDIATE FRAMING TO BE WITH 2X MINIMUM MEMBERS. FIELD NAILING 15 12' O.C. UNLE55 NOTED OTHERWISE. (1) BASED ON 0.131' x 1-1/2' LONG NAILS USED TO ATTACH FRAMING CLIPS DIRECTLY TO FRAMING. USE 0.131' x 2-1/2' LONG NAILS WHEN NAILING THROUGH 5HEATHING. (8) D5L STUDS MAY BE USED IN LIEU OF 3X MATERIAL (9) WHERE PLATE ATTACHMENTS SPECIFY (2) ROWS OF NAILS, PROVIDE DOUBLE JOIST, RIM OR EQUAL. ATTACH PER r)I=TAIL A PROVIDED W/ STEEL PLATE WASHERS Y¢' x3' x 3', EMBED ANCHORS A MINIMUM OF �' PLATE WASHER A MAXIMUM OF 1/2' F=ROM THE SHEATHED SIDE OF THE SHEAR WALL RIALS CAN CAUSE EXCESSIVE CORRRO51ON IN THE F=ASTENERS. PROVIDE HOT -DIPPED IG NOT PERMITTED) NAILS AND CONNECTOR PLATES (F=RAMING ANGLES, ETC.) FOR ALL PRESSURE TREATED FRAMING MEMBERS. i CLIPS SHEATHING 15 TO EXTEND FROM MUD5ILL TO TOP OF DOUBLE TOP PLATE FOR SILL TO MIDDLE OF STRUCTURAL RIM FOR TWO (+) STORY STRUCTURES. SEE SHEAR TAIL. lAY BE USED IN PLACE OF THE %6' 055 SHEATHING PROVIDED THAT ALL STUD SPACING 5 4-1/2' PLATE WASHER WITH AN A5TER15K (#) MAY BE 5HEAT14ED WITH 1/1(o SMART PANEL OR 5/1(o HARD IE PANEL 2D INSTALLATION) MAY BE SUBSTITUTED FOR ANCHOR BOLT. USE 1/2' A5 SPACING TYPICAL AT ALL GABLE ENDS LEGEND SIMPSON PRODUCT POINT LOAD KEY Q: MODEL NUMBER FOR EWGINEER USE ONLY MEMBER RX •ROUNDED TO NEAREST KIP TOTAL DL A 2:0 6.0 O Ln HDU5 - HF MEMBER 43400 N/A (14)-SDS)/4'x 2)/2' TO (2) STUDS SNOW 3.0 SEAM DESIGNATOR MIN. FOR PLAN REVIEW USE ONLY RX 4xO E)M (20)-SD5 Y'x 2Y' TO (2) STUDS 3-1/2"x12" GL5 HDUS - DF MEMBER l8l0# Rx STUD/COLUMN HDUII - HF MEMBER 8030# N/A ® =44 DESIGNATOR 0 =4x6 I -2x6 I=(2)2x6 a =2x4 ■=(2)2x4 ® =6x6 ®=(3)2x6 ■=(3)2x4 ® =6x8 ®=(4)2x6 •=(4)2x4 ®= 8x8 HDU14 - DF MEMBER 144450 5HEARWALL DESIGNATOR SEE SHEARWALL SGNEDULE (2) STUDS W/ (30)16d qui N/A M5TC4853 - 39000 SWI SWl SWl HOLDOWN/STRAP N/A M5TC6653 - 44900 DESIGNATOR STWD14 N/A SEE WOLDOWN/STRAP SGNEDULE (16) ad EACH SIDE WDU5 N/A (2aC514s C6I4 DETAIL CALL -OUT SEE 'Dl' 51-EETS FOR 1 CORRIESPONDING DETAIL D1 EXTEND HEADER OVER PORTAL FRAME PER DETAIL 5/DI EXTEND HEADER OVER PORTAL FRAME PER DETAIL 50I 00f= f=f;; A IINAVITY LOAED ENGINEEf;; IN DO NOT 5CY4LEN/4 11 = V) PROVIDE ALL FINAL SHOP DRAWINGS TO HODCsE ENGINEERING AS SOON AS COMPLETED. IF DESIGNER'S DRAU11NCs5 DIFFER 5TRUCTURALLY FROM SHOPS ADDITIONAL ENGINEERING WILL BE REQUIRED. INSTALL AND BRACE JOISTS AND TRUSSES PER MANUFACTURER VAIL 5HEATHING TO ALL AMING MEMBERS USING 8d W/ 3' CsRID PATTERN. INSTALL 5IMP50N L5TA STRAP /a BACKSIDE ROWS Ibd SINKER 6 311O.C. HOEDOWN 5CHEDULE SIMPSON PRODUCT F=ASTENERS Q: MODEL NUMBER ANCHOR BOLTS NAILS SCREWS CAPACITY# O Ln HDU5 - HF MEMBER 43400 N/A (14)-SDS)/4'x 2)/2' TO (2) STUDS 55 5/8x24 U.N.O. HDU5 - DF MEMBER 56450 MIN. HDUS - HF MEMBER 58200 N/A (20)-SD5 Y'x 2Y' TO (2) STUDS 55T528 OR 551/8'x24 HDUS - DF MEMBER l8l0# MIN. U.N.O. HDUII - HF MEMBER 8030# N/A (30)-5D5 /V4'x2/V2l TO 6x6 MIN. 551x30' U.N.O. HDUII - DF MEMBER 93350 HDU14 - HF MEMBER 92600 N/A (3(o) -5D5 y4'x 2/V2' TO 6x6 MIN. 551x30' U.N.O. HDU14 - DF MEMBER 144450 5THD14/5THD14RJ - 35000 (2) STUDS W/ (30)16d N/A N/A M5TC4853 - 39000 PER MFR N/A N/A M5TC6653 - 44900 PER MFR N/A N/A C514 - 2490# (16) ad EACH SIDE N/A N/A HOLDOWN NOTES: (1) INSTALL ALL SHEAR ANCHORS PER MANUFACTURER INSTRUCTIONS (2) ALL METAL CONNECTORS COMING IN CONTACT WITH PRE55URE TREATED WOOD SHALL BE SIMPSON 'Z -MAX', TRIPLE ZINC COATED, OR HOT DIPPED GALVANIZED FOR CORROSION PROTECTION. (3) SU55TITUTION WITH NON-SIMP50N ANCHORS WITH ENGINEER'S APPROVAL. (4) STWD14RJ INSTALLATION AT RIM JOIST LOCATIONS ONLY (RJ =RIM JOIST) 00 0 Z 0 W w L � 00 _ao '3) 3 0) iW� �0 W :Ec�Q���o i6 .j CO C C U >( o2 (1) O a)70�_Z'�7Y� f6 a) N V O V C O O f6 ~ N a) U L L U C� m qui+, 2a)°>.ca) eco 0 c�N��CE Nc �'� 70 O� a >, O OQ QE �C�cnag w ci-0 a) c CM o a -0 0- a -0-r- ti Q: M O Ln � Go Q � O Mwk J09 � � Ica m Q BUILDING CODE 2015 I5C WIND EXP. 5 110 MPH SEISMIC DESIGN CATEGORY D ROOF SNOW LOAD 25 P51= ENG. P.E. JOIN N. DATE 121221 REVIEW ZACK C. ANALYST ALEC H. SHEET z OF 5 SHEETS PROJECT NUMBER 200691 COPYRIGHT Q2020 I-IODCxE ENGINEERING, INC. DIGITALLY SIGNED R Ub4G 196-23-010 WITH A GLOBAL SIGN CERTIFICATE. TI$ CERTIFICATE MAY BE REMOVED BY T44E JURISDICTION II EXTENT OF HEADER II WATER HEATER D .0 DOU5LE PORTAL FRAME (Tufo BRACED PANELS) j FOR SHEAR MIN. 3"X11,' NET � � FOR A PANEL SPLICE (IF SHEATHING PER ROOF � EXTENT OF H � HEADER REQUIRED. (MAY SE NEEDED). PANEL EDGES SHALL SHEATHING SCHEDULE. SINGLE PORTAL FRAME (ONE SRACED PANEL) ,� - ,� � r WATER HEATER SEISMIC LARGER) BE BLOCKED, AND OCCUR WITHIN STAGGER SHEETS UJ/ 1/8 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o II ° ° ° ° ° ° ° ° • ° ° ° ° ° ° ° ° 2 01= MID - NE 1GHT. ONE ROUJ 01= MIN GAP. P5CL/PSC, to STRAPS LOCATED 1/3 ,SWAY � ° o ° ° d ° FASTEN SHEATHING TO HEADER z TYP. SHEATHING TO FRAMING � GIPS REQUIRED. FROM TANK CAP AND 5A6E. 3 ° d 0 W1 ad COMMON OR GALVANIZED •: � SOX N ILS IN 3' GRID PATTERN NAILING 15 REQUIRED. IF 2x� ad N,41L5 s (o I' O.C. ,�T � LAG 5OLT PER SEISMIC g 22x4'62 II r 05z ° 0 0 ° II 5LOCKING 15 USED, THE •• BIRD BLOCKING > STRAP MFR ANCHOR INTO 0 ° o o ° ,�5 SHOWN AND 3 O.C. IN ALL MUST 5E NAILED TOGETHER WITH / W 00 0 0 ° 0 0 0 0 0 0 0 0 °° FRAMING (STUDS, BLOCKING, •: /� SHEATHING 5REAK `\ 2X STUD 4 PLACES It � 0 0 0 0 0 ° O 0 0 0 0 O 0 0 0 (3) lid SINKERS. (D I 0000° °°° 0000° °°° ,�NDSILLS)T'�P. 2 ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° (2) coNTINUoUS # �4T 3 EXTEND WALL SHEATHING 2 DRYWALL PER PLAN � � RES R 0 a a a a a a a 0(D (D 0 0 0 0°°°°° TO TOP OF DOU5LE TOP 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00 FASTEN TOP PLATE TO HEADER FOOTING. . 2 X STUD WALL 000000000 000000000 W1 TWO ROWS OFI(oDSINKER # II # � PLATE 0 0 0 0 0 0 0° II 4 RE5AR FROM TOP 4 :• •:: 3 3 N,41L5 �T 3 O.C. T�'P. r � � 4 4 o 4 o° 0 0 4 12 O.C. 51MP50N H1 EACH TRU55 �o VENT FLUTE - ° ° ° (BACKSIDE) (BACKSIDE) : (BACKSIDE) ° ° 11 ° ° � L5TAI& STRAP (5ACK5IDE). USE II OR RAFTER Q 0 j S STEM UJ,�LL � ° 3 ° ° ° ° ° ° 3 LONGER SERIES To EXTEND To PERPENDICULAR TOP 2 00 °° °° °° REQUIRED ® ,ANCHOR 5A,5E To WALL � 0 0 0 0 � ( � 0 ° � � � o o � 0 0 TOP OF PONY WALL, IF PRESENT.�4PLATE INTERSECTION U.N.O. ° ° ° °LK ° 0 ° 0 MIN. WIDTH =1(o" FOR ONE STORE • • (2) H2.5,� 1=oR MULTI PLS 0 STRUCTURES, 24" FOR USE IN THE - z _ MFR TRUSSES a6 24" O.C. UJ/ X .. .. .. .. .. 1= I RST 01= TUJO STORE STRUCTURES ® �j PLAN 8001= SHEATHING .. .. .. .. .. .. .. .. .. .. - . PLAN VIEW :: :: •• : •• : •• MIN. (2) 2x4 (,ALL DM) OR (2)2x(o . ; 3 NAIL UJ/ ad s (o" O.C. FOR 2P DG D20.C. cc a) 1/1� 055 SHEATHING MIN. IN 1=IELD � _ � " N p � � co L W � Q :: :: •.: •.: •.: 5THD 14 (UN.O ON PLAN) • . • O cn ,C _SHEATH ALL GABILE ENDS _ _ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 • • • Q'— N c L p cn C L , X III III N N � �L � � U C p ' o 0 0 0 0 0 0 0 • o 0 0 0 0 0 0 0 • ' • •• USING SUJ1 SHE,4RUJ,�LL N LO p N— O z a' o• 12 .o s STEM UJ,4LL 9 HEADER EXTENDED OVER L _ v D • SCHEDULE �,_�' COU��Cm� 9 d 9 4 Q— e QQUID SHE,�RUJ,4LL _ X x •. • N O C N p O Q O Q v . d' ' �]. O . D' C z N _4.' C N C � C v D. • CC 70 v d. p r p D • i cn C C L N O O d 4 ,• 'r D O O 'r D 0 O O i di 70 — — — — — —° _ —D— A35 R5C TOP PLATE TO Q _ D— — — — — — /8' ,ANCHOR 50LT UJ/ �" EMBED cm � 0 °' —,-- —•-- --- --- ---— — --- ---— ---.— _ r r II BIRD BLOCK PER SHEAR QO C V� O (� N O -� �- Do �- SECTION ti ti U�/ MIN 3x3 x.229 PLATE WASHER " " _ °, .� N C N d v D O D O Q a d a e a o p' A WALL SCHEDULE � � CL 70 , DSL BOTTOM PLATE 0 0 o ri0 5 1 IBC FIGURA 2308b52 co WATER HEATER 5TRAFFING D1 PORTAL FRAME D1 ROOF &HEATHING D1 ad o �•x OST UNO. USS T I SPLICE. 8001= FRAMING PER PLAN. lid � 2X SOLE PLATE TO RIM 1 P G E G RDER PL E P.T. POSTS I1= LE55 THAN 8" FULL DEPTH GUSSET EACH ATTACH 8001= D I PHR,�GM iz W11(od ai (o' O.C. U N.O. W a � a� ��' 8 j 2 CUT TOP PLATE OR DROP 1= OM SOI S I (lo)lod. MIN �•X� OST BLOCKING TO DSL TOP 4 i � to R L DE P 2 3/4 T 4G TO RIM. $ �, 5EAM DO NOT CUT 5EAM PLATE PER SHEAR WALL 8 II $ � 8 • • $ (0/ "T NAIL 9 ad (0 O.C. 0 3 G SU5 LOOK Sd L ® SCHEDULE �= ,� o41 TALL POST CONNECTION.o M � � ZE 0 o 2 2 DOU5LE TOP PLATE ,AND GLUE To JOISTS. 3 - ® 3 2 X OR MFR FLOOR J015T . � GUSSET ONE SIDE ONLY � � WIDTH 01= OST UJ/ (5)l0d � O.C. PANEL EDGES ®)5HEATHING SHEATH PER 8001= ' SIMP50N 3�" C51�• STRAP D P r ��o � . • 3 - 1O O.C. FIELD NAILING. . SCHEDULE � � RIM TO TOP PLATE UJ/lid . UJ/(36) ad OR DROP 5EAM I I � II � • 3 -8 POST CONNECTION: 5LOCK ,ALL 5EARING. FACE � � • � � o.c. UN.o. .. UJ/ CONTINUOUS TOP PLATE. GUSSET BOTH SIDES UJ/(l0) GRAIN ,4T RIGHT ,ANGLES TO � �• � II STRAP M,4�' SE PLACED ON 3 �/1� 0.5.5. SHEATHING uJ/ JOIST To TOR PLATE lOd NAILS. 45 DEGREE 2X4 JOIST. II � SIDE 01= TOP PLATE - 2 x� H1= STUDS 1 O.C. 2 (3) ad TOENA I LE D LATERAL SR,�CE UJ/(�• )l � d 5IMP60N EPS, PS, (2)A35s (UN.O.) D5L TALL STUDS (6) l(od NAILS I_ I OR MA5 PER PLAN � � SHEATHING TO STUD � . � � 8 12 POST CONNECTION: SEE SHEAR WALL � . (2) l(od NAILS 0 1(o" O.C. CRO55 5RACE WITH 2X4 AS g DO NOT CUT INTO 45 4 STRUCTURAL 2x OR SCHEDULE •� SHOWN WKE( )1�d EACH END. DEGREE SHEAR CONE o1= 1-1/�•' RIM (UN.o. Bir MSR) 3 DSL 2X TOP PLATE 4 TOP 5EAM PER PLAN ,ADD 4X4 5LOCK 5ETWEEN UND I5TUR5ED 501E •:: � 4� . • . ' UJ/(�• )1 � d EACH SIDE �� � PLATE TO STUD UJ/(2) � 3/4• T G SU5 FLOOR r • � 1� d 1� O.C. � 2X CRIPPLES •:' MID-SPAN � �� � 4 8 2X ALIGN STUD UJ/ • • 8 PLYWOOD FILLER •FLOOR J015T (PER PLAN FLOOR J015T S � 12 � � (AS REQUIRED) OR FLOOR JOIST MFR) MULTIPLE STUDS FOR 4� . � 9 HEADER PER PLAN 2x SoTTOM PLATE '( D1 POINT LOAD FROM A50VE 9 � ATTACHMENT To ' SQUASH 5LOCK5 (2) l(od NAILS ro 9 REQUIRED UNDER ,ALL STRUCTUR,�L RIM PER . SHEAR WALL SCHEDULE POINT L0,4D5 DOU5LE 2X TRIMMER STUDS •. - j j RIM 50ARD To FLOOR MIN. FOR > V OPENING UNO. - g FULL HE IGHT 055 J015T WI(3) l(od • G / O G 8 - 2 LTP4 PER 5HEARWALL j No STRAP REQUIRED 11= •. ••• • ' • • 2 - D IMEN51ON PARALLEL To � SEE SHEARWALL TA5LE TA5LE CONTINUOUS TOP PLATE ' • STUDS. ,ALL WALLS 5W] FOR ADDITIONAL NAILING 11 � . • 2 • U.N.O. D1 • � _ �TOD1 � 5EAM ,SND HEADER END 5UPPOIRT � SREAK SHEATHING ,�T RIM FLOOR FLOOR CONNECTION JOIST. NAIL To STRUCTURAL RIM PER 5HE�4R UJ,�LL41 2x STUD WALL PER PLAN •SPACING0 � . EDGE NAIL OF FOOTING � � / SHEAR UJ,�LL SPECIFIED 2 CONCRETE 5LA5 PER PLAN 0 Ln 3 4 • j TOP/50TTOM PLATE To � 3)VAPOR BURR I E R 4� • STUDS UJ/ (2) l(od THRU . PER PLAN FOOTING CORNER 8 NAILS TYP. (3) l(od THRU � • NAIL FOR 6W3 5W4 4 6W5 j � 2x PT W1 ,ANCHOR 5OLT5 8 5HEAR WALLS PER 5HEARWALL SCHEDULE FOOTING CORNER FOOT ING 'T' 5TEM ALL CORNER . , / # 11-511 j j 2 x(o PT MUD 5I LL WITH � � 4 HORIZONTAL 3 FROM • g - ,ANCHOR 5OLT5 PER � � I a a TOP OF STEM AND 6 12 " O.C. SHEAR WALL TA5LE � I � . � 24STEM SHOWN � x\�\�\ice\ice\i��i��i� ® 3 30" M IN IM I UM LAP SPLICE - (MIN OF 2 PER PLATELu . ,\\ \\ \\ \\ \\ \\ \\ \ i I . \\\\ \\ - _ ' a ��i��i� �o 04 VERTICAL DOWELS 3�' WITHIN 12 01= ,�N�' CORNER) �%\\i\\i\\i\\i\\i\\i\ " \i\\i\\i\\i II j\\�\\�\\�\\ O.C. IF COLD JOINT. VERT f C,4L RE5,4R NOT - M IN FROM EDGE EXTEND TO 3 OF THE SHOWN FOR CLARITY a \\ �. \ �� ° \ • 2 CRAWL SPACE i i i �i��i\��ii�,� FOOTING 5A5E. EXTEND PERSPECTIVE OVERVIEW Qa . d . a ,�i�i 14' MIN. INTO STEMUJ,4LL N� TYP (UN.0) • ALTERNATE 5LAE3 d \ \ \ vd ON GRADE I—III— I I—III—III—III—III—III—III_ # (2) 4 CENTERED IN 2d 8 FOOTING J2" MIN a °� ALTERNATE DROPPED d BUILDING • 2 FLOOR W1P.T. x 12 H1= II r / L R P g FOOTING AND Root= STEM WALL CORNER STEM UJ,4LL T v d � � r II CODE 2015 15C • D :.a ° a : LEDGER UJ/ 5/8 x(oA5 '024 MIN. FOUNDATION D IMEN51ON DR41N5 f � REQU 1RED D • O.C. EPDXY UJ/ SIMPSON NUMBER OF FLOORS WIDTH THICKNESS WIDTH WIND • • • • • • v D SET. LU5210 J015T HANGER SUPPORTED 5Y FOOTING OF FOOTING OF FOOTING OF 5TEM 9 NATIVE UNDISTURBED SOIL EXP. 5 110 MPH • ' D 4 • /�, OR STRUCTURAL FILL PER D • • ° (UN.0) 1 FLOOR 12" K/" �" SEISMIC DESIGN . • d v 2 FLOOR 15 ° � II SII GE OTE CH • j CATEGORY D • ° 3 FL OOR 15 11 SII gII OST DEPTH I • R DEP S ROOF SNOW / JURISDICTION LOAD 25 P51= rl2 8 6 15c TA5LE 1809.E 3 CONCRETE CORNEIR5 D1 POST TO 5U5FLOCIR GIRDER CONNECTION D1 SHEAR WALL NAILING 4 5UILLDING 5ECTION D1 FOUNDATION WITH 6LA5 D1 2x STUD WALL PER PLAN ENG. P.E. (IFLOOR JOIST OR � JOHN H. LANDING DRIVEWAY APPROACH PER � 3/4 TAG 5U5FLOOR (UN.O.) DATE r 1 ARCHITECTURAL SHEETS 1.212021 2X4 LEDGER W(2) 10d (o 2 �.' ;. i. 2 FLOOR JOISTS PER PLAN REVIEW O.C. . �'.:'. . r. j GYPSUM WALL 50ARD 3 (3) 2x12 STRINGERS INSTALLED uJ/5d COOLER 2 GARAGE 5LA5 PER PLAN 1= oo I ,�N Z,�CK C. L R G RDER PER PL • II NAILS 6 S" O.C. OR TYPE ANALYST • . 5-1/2 MINIMUM MATERIAL 6 . 5/W SCREWS Q 1(o' O.C.� BULL DEPTH BLOCKING ,CLEC H. DIAGONAL SETUJEEN RISE � � � 3 3 CONTINUOUS RE5AR REQUIRED AT ,ALL 5EARING AND RUN SHEET 2 l(od NAIL 12" O.C. (UNO.) o PERSPECTIVE (RECOMMENDED 1=0R 15C 2308.4.6 3 UPPER FL IGHT OF STAIRS (0 ,� K CONTROL) - Igo 2 o CR c Co ROL SUPPORTED ON 3/4 T 4G 2x PT UJ/ ,ANCHOR 5OLT5 V II II. PER 5HEARWALL SCHEDULE ad NAILED V O2.0 i. � ad NAIL 12 O.C. ON ,ALL • � COMPACTED S,�ND/GR,4VEL '0 (0 is PANEL EDGES 12 O.C. �: FRAMING MEM5ER5 NOT AT \\moi\\moi I I . � � � 04 HORIZONTAL 31-51 FROM g FIELD PANEL EDGES (UN.0) _ � z - TO 01= STEM ,�N 12" O.C. CONTINUOUS BUfLDING -�%��!i��i�ei��i��i��i II.° 2X4 THRUST 5L OCK W110d ��\\�\\�\\�\\ 24" STEM SHOWN 30 F5 SHEETS ORIENTATION OF CORNER � `� i i i i I ' o . FOOTING PER FOOTING �\i .\\ice II g is (oO.C. NAIL TO LANDING : - �\i \ , I' II 9 STUD MAY VAR' DETAIL �!�\ � � , I 04 VERTICAL DOWELS 6 3� J015T 8 • � PROJECT NUMBER O.C. IF COLD JOINT. EXTEND • 3/�' TSG SUB Loon ad NAIL 6 (o O.C. ALL .\\� • i�--- X00691 o. HOLDOWN PER PLAN 2 y FRAMING MEM5ER5 AT � 2 ° 545E. EXTEND 14' MIN. g 2X8 LANDING JOISTS PANEL EDGES 4 12" O.c. I=I � I, I „ INSIDE CORNER 2 ON ,4 FRAMING M M 5 p D -III—I III-1 I I—III—III-1 I I INTO STEMUJ,�LL (UN.0) A R l od a0 � O.C. RIM TO ALL R G E 5ER 0 NOT AT AN 5 •,� ,�\ � \ \ \ \ � � 12 FR05T DEPTH Y w 21 12 TOP PLATE PANEL EDGE \ \ \ \ \ g DEP 5 // .. :r JURISDICTION (3) 1od TOE N,�1L5 O z \ \ \ Sd N,� L �' O C (LL (2) CENTERED IN FOOTING . I • • MIN. FOUNDATION ON DIMENSION P�4NEL EDGESXUN.0) ,�\ \\ \ ' ' NUM OF 00 5 WIDTH THICKN 55 WIDTH � �� \ BER L R D � D 11 NOTCH STRINGER TO REST SECTION i / ./ • • •. • .: SUPPORTED 5Y FOOTING OF FOOTING OF FOOTING 0F STEM FOOTING AND 8001= STRINGERS SPANNING OVER ON LEDGER � p • • • •• • • II II II F�' 1 00 12 �o DRAINS IF REQUIRED �,�z o,� STE (o STEPS MUST 5E SUPPORTED ,I II II �s 2X TREADS WI(3) 10d � 2 FLOOR 15 ( 8 NATIVEUN 15TU 501 3�ONAL� W14X(o 5EAM ON 4X4 POSTS, 12 II II II 12 D RSED L POST TO 18" CONCRETE SOOTING EACH STRINGER 3 FLOOR 18 S S OR STRUCTURAL FILL PER �0 3 OUTSIDE CORNER DETAIL GEOTECH COPYRIGHT c 2020 OR STUDuu,�LLrl n 7 O 37 / I5C TA5LE 1009.1 4 COPYRIGHT ENGINEERING, INC. TWIS DOCUMENT BIAS BEEN DIGITALLY SIGNED PER 5TAIRLANDING CONNECTION D1 IN61DE/OUT61DECORNERD1 CONTINUOU5 5TRIF FOOTING AT GARAGE ENTRY D1 �OI�ND�TION l�ITH ��OOR JOf STS D1 WAC 1%-23-070WITWA GLOBAL SIGN CERTIFICATE.T14E CERTIFICATE MAY BE REMOVED BY THE JURISDICTION G UNR�STRAIN�D RETAINING WALL SCHEDULE r) r) 1 Q n r=P r ARI ;= ;=T.11'7 TIMI 144 'I /I r r C'N • 0( I / EDGE H UJ IT VERTICAL 5 K D LL I II I \ �rr�«/�� �I Z�/ 1 I \VrVV 10iL11 DOUE3LE TOS PLATE (U.N.O. ON PLAN) n r-nkrrikii gni ic, \/=CDtlr- AI ........ U FACE OF FOOTING 51TE PLAN, 5TRUCTURE LOCATION, GEOTECHNICAL REPORT 2 TOP OF SLOPE AND SITE WORK ,ARE THE RE6PON6151LITY OF THE 5U I LD ERLu F AND CIVIL/GEOTECHNICAL ENGINEER. z 0 4' 8' s' #4 -9 12' OC 24' 0 4' 4'1'-(o' ON 12' 04 .9 12' OC 40' (o' 4' I r- I r r ,� r I- u r r 61 s s 12 � 10 oc 9 10 S'1'-10 3' 12' 05 a 9' OC 6'-3' 11' 1-3/4' Q UJIDH FOOTING SASED ON I$00 PSF SOIL `�J vvi i II \MV NV r Vim i ivrtV N � SHEATHING OVER GABLE O N/3 BUt NEED NOT > � FRAMING UNLESS A GEOTECHNICAL REPORT IS PROVIDED t0 EXCEED gym' MAX w CONCRETE lf'cJ = 2500 pal O HORIZONTAL REBAR NODGE ENGINEERING t�4E BEARING SOILS ARE ,4SSUMED REBAR (f = 60 ksi 114114 �g,qR ,dt 10110CO 6' TIMBERLOK OR 6' SDUJC KIL 70 BE 1500 PSS, WHEN PROVIDED FOLLOW ALL DIRECTION � PASSIVE = 25250pcf 3 AT 16' O.C. � ACTIVE SOIL = 35 pcf O VERTICAL R�BAR SPLICE 30' � OF THE GEOTECHNICAL REPORT. (4) TOE OF SLOPE p SOIL BEARING = 1600 psfFOR #TOP PLATE TO � o R�BAR)�BFOOTINCx RSB R CORD CONNECTION PER O N/2 BUT NEED NOT � * ��� o S�IE,4RlUALL SCHEDULE �XC�ED 15' MAX � U -D 4� tRANSv�RSE R�B�4R � ` �� � o o J O FACE OF StRUCtURE � O 18 O.C. ` � D (VARIES - SEE 7A5LE) NOTES o 9MIRA-DRAIN 600 TIED INTO � �-INSTALL SCREWS UPWARD 2 FOOTING DRAIN Sl'StEM � �j tNROUCzN COP PLACES INTO p � BACKFILL WITH FREE � � CENTER OF BOttOM TRUSS Z � DRAINING WELL GRADED 2 GNOSZD. �o � 2 MATERIALS 5°r, FINES MAX. 5 LL OKE1' (NOT REQUIRED IF SLAB -BRACE tRUSSES PER SGSI. � m c � a 2 o PR�SEN7 A7 FOOTING) CONSULT TRUSS MANUFACTURER � z � � � � N .� o o N FOR BRACINCx i�G2UIREMENtS. 3 � W � L m � a � s � o � FOOTING 12' MIN BLOW GRADE. BELOIUCxRAD� 15 NOT �L� J `3LcoccU L� Q �mm�-ocm'-w m '�^ V m���coZm0o `, � FOOTING t0 BEAR ON REQUIRED I� SLAB PRESENt R�o �a>iC L- E a)'i��vc m- Y FIRM UNDISTURBED O�OOTINCx REBAR *� � lf�' O.C. � _ � Z � N = � _ � £ E NATIVE 501L v`��awit�scov�R UU'O�. ui <ca ,oB cmo�� -r- 15c: 10012 1 1 26 2�2 18 iRc FIG R40311.115C FIG 1500.1.1 l 4 `° -0 0 �- UNIRE5TFRAINELD CONCRETE WALL - 40 PSS SURCHARGE - 2 015 IBC D2 D2 GA5LE ENE) TRUSS 51RACING D2 FOUNDATION CLEARANCE SROM 6LOFE5 D2 2 � CD GABLE END SCISSOR TRUSS DRAINAGE - EXTERIOR GRApES ADJACENT t0 THE WALLS OF THE HOUSE ARE t0 BE SLOPED j (2) 2x4 LAMINAtIONS lU/ CI) OR iZ4�tER PER PLAN $ � �" $ AUJAI' FROM THE 5TRUCTURE TO ACHIEVE 5URFACE DRAINAGE. 5U55URFACE DRAINS A7 OR � O O (8) 16d NAILS STACzCxER�D = � � _ 0 � "' ROUJ OF STAC�sCzEi�ED 1(Id A7 �ACN SID OF TOP 0 BELOU1 THE FOOtINCx/SL�4B ELEVATION ARE t0 BE USED FOR ANY BASEMENt OR RETAINING � COMMON WIRE NAILS a 12 cc `�' M/N O RAKE FRAME STUDS TO "` "' �,4ro PLATS SPLICE. WALLS OVER 3 FEET IN HEIGHT. DRAIN5 ARE 70 CONSIST 0F RIGID PERFORATED 4' PVC PIPE � �oR p tRuss��tER �ottoM U SURROUNDED B1' WA5HED PEA -GRAVEL OR GRANULAR SILL WITH LASS 7N,4N 5°ro SINES. PLACE N O C2) 2x6 LAMINATIONS lU/ l2) �"�rF S�Li� CHORD. DO NOT BREAK � ROW OF StEkED I(�d 2 � F O �3) 16d NAILS StAC��R�D 57UD5 A NONUJOYEN-CxEOTEX71LE FILTER FABRIC BETUJEEN THE DR�41N,4C�E M,4TE�21,4L AND THE � m � ,4t EACH SIDS OF BOttOM REMAINING WALL BACKFILL t0 REDUCE Slit MIGRATION INTO THE DRAINAGE ZONE. PLACE CCI N o �, COMMON WIRE NAILS IS6'oc PLAN SPLICE. O O BREAK SHEATHING At DBL EACH SIDS TOP PLACE OR USE THE FILTER FABRIC SUCH THAT 17 FULLY SEPARATES THE DRAINAGE MATERIAL AND THE (2) 16d NAILS 6 16' cc INTO • ' • . CONTINUOUS SHEATHING on BACKFILL AND EXTEND5 OVER THE COP OF THE DRAINAGE ZONE.SCUDS-1/2' ,,-�` O (3) 2x4 LAMINA710NS W/ (1)� 4 3 .. O 6' tIMBERLOK OR 6' SDUJC � THE LEVEL OF THE PERFORATIONS IN THE PIPE ARE t0 BE AT THE BOTTOM OF THE FOOtINCxS I' a� ROW OF S7AC�ERED 3f�d, - SIMPSON 36" CSI MAY BE . O, At 16' O.C. � o COMMON IUIRE NAILS a 16 0 4 AND THE DRAINS ARE TO BE CONSTRUCTED WITH SUFFICIENT GRADIENT 70 ALLOW GRAVITY � EACH SIDS USED IN LIEU OF NAILING AS O TOP PLATE TO BOTTOM � D15CHAIRGE AWAY FROM THE 5TRUCTURE. THE PEIRFORATION5 ARE t0 BE LOCATED ON t�4E �-� INDICATED.(N07 SNOUJN FOR 2 5 CHORD CONNECTION PER � � O (3) 2x6 LAMINA710N5 W/ (2) CLARItI') coN��T � SNEARUJALL SCHEDULE. -� LOWER PORTION OF THE PIPE. ��� ROIUS OF STAGGERED 30d �eATN�� SNEA 2-1/2 COMMON WIRE NAILS 8'oc RETAINING WALL5 OR 5A5EMENT5 WALL5 ARE TO BE BACKFILLED WITH A MINIMUM 12 -INCH o �-1/211 "' EACH SIDS � CHICK WASHED GRAVEL BLANKET OR LINED WITH A [DRAINAGE MAT SUCH AS MIRA-DRAIN 6001 o I -I/2' OR WELL GRADED AND DRAINING NATIO SOILS OVER THE BULL HEIGHT OF THE WALL5 NOTE: PLACE SPLICE (EXCLUDING THE FIRST 1 FOOT BELOW THE SURFACE). tHIS DRAINAGE MATERIAL IS t0 TIE INTO I APPLIES WHEN NO OTHER THE FOOTING DRAIN 5Y5TEM. 2 SPLICE IS INDICATED. ROOF AND SURFACE RUNOFF ARS N07 70 BE DISCHARGED INTO THE FOOTING DRAIN 5Y5TEM 3 AND SHOULD BE HANDLED Bl' A SEPARATE RIGID TIGNtLINE DRAIN 5Y5TEM.� 23 ri9r15 r2�7' mw CD8 B33 Som ac CONCRETE WALL DRAINAGE D2 NAILING SCHEDULE AOR BUILT-UP COLUMN D2 PLATE 5FLICE D2 VAULTED GA5LE ENE) DZ � M O (:D UJALL �RAMINCx 4116 I• 00) • O M6T60 OR (2) CS14 � � Ln MANUFACTURED ROOFO BETIUEEN PONY IUABOVE WHEN FOUNDATION ALL4 WALL O I/2" MIN FROM CORNER LnM � �C� • TRUSS UItN ENERGY HOLDOUJN SPECIFIED O O SN�AR WALL NAILING PER � o O WHERE �OOTINCx SECTION o°, O �R MAY BE oil- � J � Q ll)4 R�BA FOUNDATION REBAR OR PLAN gFC � 'A' IS MORE THAN 8' ° �° � POSt TENSION 3 T��N � PROVIDE 4' CSI6 EACH° o 0 0 0 °, O 7/16 OSB OR SMART SIDE SIDE OF SPLICE W/8-16� W/8 -16d o o O J o o � ° ° PANEL BLOCKING lU/ Sd 6 COMMON NAILS � O 24' MIN REBAR LENGTH00 � ♦ J 6' cc INTO DOUBLE COP � ° COP PLACE SPLICE LINE PLATS 8 TOPCHORD BIRD o 0 0', �r LLI ��aivE INTERIOR PERSPECTIVE EXTERIOR BLOCK . �. NOTE: NOLDOIUNS At 0 0 O ,1 ( (2) 2X PLATE 0 o � ° ° CORNER ARE SPACED Z Q (4)1/2"ROOF SNEATNINCx PER PLAN FROM EDGE. M UJ/ ad a 6' cc INTO BIRD � a O O NOLDOUJN PER PLAN BLOCK BLOCKING. ° . � � � ° o . °- �' �� d a a � O PONY WALL SNEAtNING 4 - 3 .� � � O CLEAR SPAN 11MAXIMUM. �j S SIMPSON Nl CLIP. TYPICAL � a � . .. � 80.. � �IE,4R NAILING t0 MATCH � •' . � � \ FOR TYPE � � ; ; � % RJ NOLDOIUN � AT ALL TRUSS BOTTOM a ���V WALL ABO � 3 � 0AOR NON RJ NOLDOIUNS 3 � CHORD TO DOUBLE 70P � � � ° � .�' . � � �. � O 6' MAXIMUM PONT' WALL ': J w 2 BUILDING ..: a PLATE INtER5EC710N5 g . � .. a. � . � IDU NOLDOUJN � .' O COMPRESSION BLOCKINCx CODE 2m15 IBC SOFFIT MATERIAL PER a � ,�. a O (WHEN SPECIFIED) O (2) ad NAILS 'a8' O.G. OR WAND EXP. B llm MPH 2 DESIGN PLAN o ° aa _ 12, MIN � PSA5TUD PACK OR POST PER , 16d 6 16' O.C. SEISMIC DESIGN �� Strong -TW CATEGORY D � . $ .. � a � . � BUILDER t0 DETERMINE STPD STI�D�J ,rz,us SECTION StND OR StND/RJ IS ROOF SNOW r28 Z4 20 APPAPPROPRIATE.16 LOAD 2� PSS " � RAI&ED HEEL TO 5HEAR WALL CONNECTION D2 D2 STEP FOOTING 4 PONY WALL FRAMING D2 5IMP50N STIED D2 2(� THE TRUSS DESICsNER'S CxABLE SND BRAG ENG. P.E. JOIN N. J 25 21 O EXTEND SN�ATNING TO 17 DETAIL TAKES PRECEDENCE. USS THISj 2x6 MINIMUM BLOCKINCx DATE LOWER TRUSS BOTTOM �'�� DETAIL IF THE TRUSS DESIC�NER DOES N07 O g�TUJEEN TRUSSES OR 121221 CHORD PROVIDE A C�ABLE SND BRAG DETAIL . RAFTERS, NAIL ROOD REVIEW O NAIL ALL ADJACENT BOTTOM CHORD TRUSS UJ�Sd��13�OTO BLOCKING ANALYST zACK C. O TRUSS CHORDS UJ/ (3) 5R,4CING (i' MINIMUM) . ad NAILS t0 WALL SCUD At 24' O.G. ALONG ALEC H. LENGTH OF WALL. C6) Imd NAILS SHEET � O BLOCKING BEHIND ATTACH t0 EACH tizUSS O 2x6 DIAGONAL SHEATHING CUT FOR WITH (2) 26 ' d NAILS. o , o BRACING SPACED � 24 • o 0 o O.C. ATTACHED UJ/ (3) FLASNINC� 16d NAILS 2.. SIMPSON CxBC 4 OF 5 SHEETS 01 2 � O (INSTALLED IN PAIi�S) (o PROJECT NUMBER O DOUBLE COP PLAN 200691 O GABLE SND TRUSS �W ARO 2x4 BOTTOM CHORD X of w 1 iQ TRUSS BRACING 8' MINIMUM 's 24' O.C. ALONG .' WALL BELOW. ATTACH t0 EACH TRUSS 37 8 6 110 W1 (2) 16d NAILS s -rE��'G��`� �J SS�ONALEN 4 EXAMPLE RESIDENCE r29 25 21rl7�oo�� �u�i"r���� � INC. T1415 DOCIIIIIIIIIIENT �IAS BEEN DIGITALLY SIGNED MR D2 D2 �XT�ND SI���4T�IINC� TO TRUSS BOTTOM C�40�D D2 C�,48L� SND B��CE D2 ���-���WIT�A��$ CERTIFICATE. �� 1. GENERAL STRUCTURAL NOTES ALL LATERAL LOAD RESISTING AND GRAVITY LOAD RESISTING (IF SPECIFIED) STRUCTURAL MEMBERS ARE SHOWN ON THE ENGINEERING SHEETS AND DETAIL PAGES. THE ENCLOSED ENGINEERING CALCULATIONS DOCUMENT THE ANALYSIS USED TO DETERMINE THE STRUCTURAL MEMBERS OF THE ENGINEERING SHEETS. THE ENGINEERING CALCULATIONS ARE NOT REQUIRED TO BE REFERENCED FOR CONSTRUCTION AND ARE NOT REQUIRED BY ENGINEERING TO BE ONSITE. THIS ENGINEERING HAS BEEN CALCULATED TO RESIST CODE SPECIFIED VERTICAL AND LATERAL (WIND & SEISMIC) FORCES AFTER THE COMPLETION OF ALL STRUCTURAL ELEMENTS. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO ENSURE STRUCTURAL STABILITY DURING CONSTRUCTION INCLUDING JOB SITE SAFETY; ERECTION METHODS; TEMPORARY SHORING, FORMWORK AND BRACING; USE OF EQUIPMENT AND CONSTRUCTION PROCEDURES. ANY DISCREPANCIES FOUND AMONG THE DRAWINGS, ENGINEERING, AND/OR THE SITE CONDITIONS MUST BE REPORTED TO THE ARCHITECT AND ENGINEER WHO SHALL CORRECT SUCH DISCREPANCY IN WRITING. ANY WORK DONE BY THE GENERAL CONTRACTOR AFTER DISCOVERY OF SUCH DISCREPANCY SHALL BE DONE AT THE GENERAL CONTRACTOR'S RISK. THE GENERAL CONTRACTOR SHALL VERIFY AND COORDINATE ALL DIMENSIONS PRIOR TO CONSTRUCTION. STRUCTURAL DRAWINGS GOVERN. IF THERE ARE CONFLICTS WITH ARCHITECTURAL DRAWINGS, CONTACT HODGE ENGINEERING IMMEDIATELY. CONSTRUCTION OBSERVATION BY THE STRUCTURAL ENGINEER IS NOT PROVIDED. THIS ENGINEERING IS NOT INTENDED I N ANY WAY TO REVIEW OR APPROVE THE CONTRACTOR'S CONSTRUCTION PROCEDURES. STANDARDS ALL METHODS, MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE 2015 INTERNATIONAL RESIDENTIAL CODE (IRC) AS AMENDED AND ADOPTED BY THE LOCAL BUILDING OFFICIAL OR APPLICABLE JURISDICTION. THIS ENGINEERING IS TO THE 2015 INTERNATIONAL BUILDING CODE (IBC) 2. DESIGN CRITERIA VERTICAL LOADS IBC TABLE 1607.1 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS USE LIVE LOAD ATTICS WITH STORAGE (UNINHABITABLE) 20 PSF ATTICS WITHOUT STORAGE (UNINHABITABLE) 10 PSF DECKS 60 PSF EXTERIOR BALCONIES 60 PSF FIRE ESCAPES 40 PSF GUARDRAILS AND HAND RAILS 200 POUNDS GUARD RAIL INFILL COMPONENTS 50 POUNDS PASSENGER VEHICLE GARAGES 40 PSF ROOMS OTHER THAN SLEEPING ROOMS 40 PSF SLEEPING ROOMS 30 PSF STAIRS 40 PSF LATERAL FORCES 1n� 16�i7i ASCE 7-10 DIRECTIONAL PROCEDURE FOR BUILDINGS OF ALL HEIGHTS SEISMIC -- SEISMIC IMPORTANCE FACTOR PER ASCE 7-10, Ie = 1.00 BUILDING OCCUPANCY RISK CATEGORY PER ASCE 7-10 TABLE 1.5-1= II SOIL SITE CLASS PER ASCE 7-10 TABLE 20.3-1= PER PLAN SEISMIC DESIGN CATEGORY IBC TABLE 1613.3.5(1) & 1613.3.5(2) = PER PLAN ANALYSIS PROCEDURE USED = EQUIVALENT LATERAL FORCE ANALYSIS RESPONSE MODIFICATION FACTOR R = 6.5 M101191" HODGE ENGINEERING IS NOT A GEOTECHNICAL ENGINEERING FIRM AND CANNOT MAKE A DETERMINATION OF SITE ADEQUACY FOR CONSTRUCTION. IF SITE SOIL BEARING CAPACITY OR SITE SLOPE IS IN DOUBT OR MAY AFFECT CONSTRUCTION THE BUILDER MUST CONTRACT A GEOTECHNICAL ENGINEERING FIRM FOR A SOILS REPORT. PROVIDE HODGE ENGINEERING WITH ANY GEOTECHNICAL INFORMATION PRIOR TO SITE PREPARATION. IF OWNER AND BUILDER THROUGH THEIR FEASIBILITY STUDIES DETERMINES THAT A GEOTECHNICAL REPORT IS NOT NEEDED THE FOLLOWING SOIL PARAMETERS AND METHODS ARE ASSUMED AND ACCEPTED BY THE OWNER AND BUILDER: SOIL BEARING PRESSURE: 1500 PSF (ASSUMED)* ACTIVE PRESSURE -UNRESTRAINED: 35 PCF (ASSUMED) PASSIVE RESISTANCE: 200 PCF (ASSUMED) COEFFICIENT OF FRICTION:.35 (ASSUMED) *1/3 INCREASE ALLOWED FOR SEISMIC OR WIND LOADING ALL FOOTINGS SHALL BEAR ON FIRM UNDISTURBED EARTH OR COMPACTED STRUCTURAL FILL FOLLOWING SPECIFICATIONS NOTED BELOW. AREAS OVER -EXCAVATED SHALL BE BACKFILLED WITH LEAN CONCRETE (Fc=2000 PSI) OR COMPACTED STRUCTURAL BACKFILL. "STRUCTURAL BACKFILL" SHALL BE FILLED WITH APPROVED WELL -GRADED MATERIAL. MAXIMUM SIZE OF ROCK 4". ORGANIC MATERIAL AND DELETERIOUS MATTER NOT ALLOWED. COMPACT TO AT LEAST 95% OF IT'S MAXIMUM DENSITY AS DETERMINED BY ASTM D-1557. WHERE REQUIRED BY THE BUILDING OFFICIAL, THE CLASSIFICATION AND INVESTIGATION OF THE SOIL SHALL BE MADE BY A REGISTERED DESIGN PROFESSIONAL (IBC 1803.1). UNLESS A SOILS INVESTIGATION IS PROVIDED FOUNDATION DESIGN IS BASED ON AN ASSUMED AVERAGE SOIL BEARING OF 1500 PSF. ORGANIC SILT, ORGANIC CLAYS, PEAT OR UNPREPARED FILL SHALL NOT BE ASSUMED TO HAVE A BEARING CAPACITY. THIS ENGINEERING IS BASED ON SITE CLASS D SOILS IN ACCORDANCE WITH IBC TABLE 1613.3.5. (UNLESS NOTED OTHERWISE) SITE GRADING: THE GROUND IMMEDIATELY ADJACENT TO THE FOUNDATION SHALL BE SLOPED AWAY FROM THE BUILDING PER IRC R401.3. EXPANSIVE SOILS SHALL BE REMOVED. FREE DRAINING BACKFILL MATERIAL FOR RETAINING AND BASEMENT WALLS CLEAN, FREE DRAINING, WELL GRADED SAND OR GRAVEL MATERIAL WHOSE MAXIMUM PARTICLE SIZE DOES NOT EXCEED 3/4" AND WHOSE FINES CONTENT (MATERIAL PASSING THE N0. 200 SIEVE) DOES NOT EXCEED 5%, WITH A MAXIMUM DUST RATIO %PASSING U.S. NO. ZOO SIEVE - 2/3 MAX. PASSING U.S. N0. 400 SIEVE 4, CONCRETE CONCRETE WALLS EXCEEDING 8' IN HEIGHT MUST BE DESIGNED AND STAMPED BY A LICENSED PROFESSIONAL ENGINEER. IF CONCRETE WALLS OVER 8' HAVE BEEN DESIGNED FOR THIS PROJECT THEY WILL BE SPECIFIED ON THE PLAN AND SHOWN IN THE DETAILS. WOOD SHALL NOT BE USED TO SUPPORT MASONRY OR CONCRETE UNLESS SPECIFICALLY NOTED OTHERWISE ON THE S -SHEETS (IBC 2304.12). ALL BASEMENT WALLS BELOW FINISHED GRADE SHALL BE WATER PROOFED OUTSIDE BY APPROVED METHODS AND MATERIALS. CONCRETE: SHALL BE MADE WITH PORTLAND CEMENT ASTM C-150 TYPE II OR TYPE I AND SHALL BE READY MIXED PER ASTM C-94. MIX DESIGNS: THE CONTRACTOR SHALL DESIGN CONCRETE MIXES THAT MEET OR EXCEED THE REQUIREMENTS OF THE CONCRETE MIX TABLE FOR THE BEARING STRENGTH SPECIFIED. THE MIX DESIGNS SHALL FACILITATE ANTICIPATED PLACEMENT METHODS, WEATHER, TEMPERATURE, REBAR CONGESTION, AND ALL OTHER FACTORS REQUIRED TO PROVIDE A STRUCTURALLY SOUND AND ACCEPTABLE FINISHED PRODUCT. WATER REDUCING ADMIXTURES MAY BE USED TO MEET THESE REQUIREMENTS. MAXIMUM SLUMP SHALL BE 5". ADMIXTURES: ADMIXTURES SHALL BE BY MASTER BUILDERS, W.R. GRACE, OR PRE -APPROVED EQUAL. ALL MANUFACTURER'S RECOMMENDATIONS SHALL BE FOLLOWED. WATER: SHALL BE CLEAN AND POTABLE PROVIDE 3000 PSI @ 28 DAYS MINIMUM FOR DURABILITY AT BASEMENT WALLS, FOUNDATION WALLS, EXTERIOR WALLS, PORCHES, CARPORT SLABS AND STEPS EXPOSED TO THE WEATHER AND FOR ALL GARAGE FLOOR SLABS. CONCRETE SHALL BE AIR ENTRAINED. TOTAL AIR CONTENT (PERCENT BY VOLUME OF CONCRETE) SHALL BE NO LESS THAN 5 PERCENT OR MORE THAN 7 PERCENT. NO SPECIAL INSPECTION FOR 3000 PSI CONCRETE - DURABILITY ONLY. REINFORCING STEEL: SHALL CONFORM TO ASTM A-615, GRADE 60. PLACE PER ACI 315 AND ACI 318. VERTICAL AND HORIZONTAL REINFORCEMENT SHALL BE THE LONGEST LENGTHS PRACTICAL. WHERE SPLICES ARE NECESSARY THE LENGTH OF LAP SPLICE SHALL BE A MINIMUM OF 30 INCHES FOR #47 38 INCHES FOR #5, AND 45 INCHES FOR #6. THE MAXIMUM GAP BETWEEN NON -CONTACT PARALLEL BARS AT A LAP SPLICE SHALL NOT EXCEED 5 INCHES. CRACKS: UN -REINFORCED CONCRETE WILL CRACK. SLAB CRACK CONTROL IS RECOMMENDED IF CRACKS ARE UNDESIRABLE AND IS AS DIRECTED BY THE OWNER. OWNER IS TO DETERMINE THE ACCEPTABLE AMOUNT OF SLAB CRACKING PRIOR TO CONSTRUCTION AND REQUEST APPROPRIATE CRACK CONTROL. CONCRETE MINIMUM COVER OVER REINFORCEMENT CONCRETE CAST AGAINST EARTH = 3" EXPOSED TO WEATHER OR EARTH = 2" WALLS AND SLABS NOT EXPOSED TO WEATHER = 3/4" BOLTS MACHINE BOLTS (M.B.): ASTM A-307, GRADE A ANCHOR BOLTS (A.B.): ASTM F1554, GRADE 36, CLASS 2A 5, CARPENTRY NAILS: CONNECTION DESIGNS ARE BASED ON "COMMON WIRE" NAILS WITH THE FOLLOWING PROPERTIES: PENNYWEIGHT DIAMETER (IN.) LENGTH (IN.) 8d MAX. 24/2 MIN. ITEM DESIGN f'c (PSI) MAX. W/C MIN. (2)1 AGGREGATE NOTES CEMENTITOUS 4 GALV (G60) RATIO FLYASH (PLY) SIZE (IN) AND WEB FILLER (1) MATERIAL (L/240 L.L.) 2x GANGLAM GALV (G185) MASONRY WALLS (4) CEILING JOIST NOT ATTACHED TO Fb=1700 PSI (SACKS/YARD) FOUNDATIONS 2500 @ 28 DAYS 0.45 - - 3/4 - - 5-1/2 STEMWALLS 3000 @ 28 DAYS 0.45 100 3/4 - - 5-1/2 SLAB ON GRADE 3000 @ 28 DAYS 0.45 100 3/4 1-3/4" RIGID -LAM 5-1/2 CONCRETE FRAME 2500 @ 28 DAYS 0.45 100 3/4 - - 5-1/2 PROVIDE 3000 PSI @ 28 DAYS MINIMUM FOR DURABILITY AT BASEMENT WALLS, FOUNDATION WALLS, EXTERIOR WALLS, PORCHES, CARPORT SLABS AND STEPS EXPOSED TO THE WEATHER AND FOR ALL GARAGE FLOOR SLABS. CONCRETE SHALL BE AIR ENTRAINED. TOTAL AIR CONTENT (PERCENT BY VOLUME OF CONCRETE) SHALL BE NO LESS THAN 5 PERCENT OR MORE THAN 7 PERCENT. NO SPECIAL INSPECTION FOR 3000 PSI CONCRETE - DURABILITY ONLY. REINFORCING STEEL: SHALL CONFORM TO ASTM A-615, GRADE 60. PLACE PER ACI 315 AND ACI 318. VERTICAL AND HORIZONTAL REINFORCEMENT SHALL BE THE LONGEST LENGTHS PRACTICAL. WHERE SPLICES ARE NECESSARY THE LENGTH OF LAP SPLICE SHALL BE A MINIMUM OF 30 INCHES FOR #47 38 INCHES FOR #5, AND 45 INCHES FOR #6. THE MAXIMUM GAP BETWEEN NON -CONTACT PARALLEL BARS AT A LAP SPLICE SHALL NOT EXCEED 5 INCHES. CRACKS: UN -REINFORCED CONCRETE WILL CRACK. SLAB CRACK CONTROL IS RECOMMENDED IF CRACKS ARE UNDESIRABLE AND IS AS DIRECTED BY THE OWNER. OWNER IS TO DETERMINE THE ACCEPTABLE AMOUNT OF SLAB CRACKING PRIOR TO CONSTRUCTION AND REQUEST APPROPRIATE CRACK CONTROL. CONCRETE MINIMUM COVER OVER REINFORCEMENT CONCRETE CAST AGAINST EARTH = 3" EXPOSED TO WEATHER OR EARTH = 2" WALLS AND SLABS NOT EXPOSED TO WEATHER = 3/4" BOLTS MACHINE BOLTS (M.B.): ASTM A-307, GRADE A ANCHOR BOLTS (A.B.): ASTM F1554, GRADE 36, CLASS 2A 5, CARPENTRY NAILS: CONNECTION DESIGNS ARE BASED ON "COMMON WIRE" NAILS WITH THE FOLLOWING PROPERTIES: PENNYWEIGHT DIAMETER (IN.) LENGTH (IN.) 8d 0.131 24/2 10d 0.148 3 16d 0.162 3-1/2 20d 0.192 4 WOOD SHEATHING (STRUCTURAL): SHEATHING SHALL BE PLYWOOD (CDX) OR ORIENTED STRAND BOARD (OSB). PLYWOOD SHEATHING SHALL BE 5 -PLY MINIMUM WHERE INDICATED AS 3/4" OR THICKER. WOOD SHEATHING SHALL BE "RATED SHEATHING" CONFORMING TO PS1-95 AND/OR PS2-92. ALL PANELS SHALL BEAR THE STAMP OF AN APPROVED GRADING AGENCY. SPAN RATING SHALL BE PROVIDED AS FOLLOWS: ROOF (32/16); WALLS (32/16); FLOORS (2011 O.C.) UNLESS NOTED OTHERWISE. ALL WOOD SHEATHED WALLS SHALL BE BLOCKED AT ALL PANEL EDGES UNLESS NOTED OTHERWISE. GLUE -LAMINATED MEMBERS: PER ANSI/RITC A190.1. MEMBERS SHALL BE COMBINATION 24F -V4 DOUGLAS FIR FOR SIMPLE SPANS AND 24F -V8 DOUGLAS FIR FOR CANTILEVERED SPANS AND TRUSS CHORDS (FB=2400 PSI, FV=240 PSI, E=1.8X10^6 PSI) AND DOUGLAS FIR COMBINATION 2 FOR COLUMNS AND TRUSS WEB MEMBERS, ALL WITH EXTERIOR GLUE. ALL MEMBERS TO HAVE AITC OR APA-EWS STAMP. FRAMING LUMBER: EACH PIECE SHALL BEAR THE GRADE TRADEMARK OF THE WEST COAST LUMBER INSPECTION BUREAU (WCLIB), WESTERN WOOD PRODUCTS ASSOCIATION (WWPA), OR OTHER AGENCY ACCREDITED BE THE AMERICAN LUMBER STANDARD COMMITTEE (ALSC) TO GRADE UNDER ALSC CERTIFIED GRADING RULES. SPECIES AND GRADE (BASE DESIGN VALUE) (U.N.O.) 1. 2X TO 4X JOISTS, PURLINS AND HEADERS. "DOUG FIR -LARCH" NO. 2 (Fb=900 PSI, Fv=180 PSI) OR "HEM -FIR" NO. 1 (Fb=975 PSI, Fv=150 PSI) 2. 6X POSTS AND COLUMNS. "DOUG FIR -LARCH" NO. 1(Fc=1000 PSI) 3. EXTERIOR STUDS, INTERIOR BEARING WALLS "HEM -FIR" NO. 2 4. INTERIOR NON-BEARING STUD WALLS. "HEM -FIR" NO. 2 STUD GRADE 5. 2X & 3X T&G DECKING: "DOUG FIR -LARCH" COMMERCIAL (Fb=1650 PSI, E=1700 KSI) COLUMNS: ALL COLUMNS NOT SPECIFIED OR OTHERWISE NOTED ON THE PLAN ARE TO BE TWO STUDS. MULTIPLE STUDS ARE TO BE SPIKE LAMINATED TOGETHER WITH (2)16d NAILING AT 6" ON CENTER STAGGERED (U.N.O.). ALL COLUMNS SUPPORTING GIRDER TRUSSES OR GLUE LAMINATED BEAMS ARE TO BE THREE STUDS. ALL BEARING WALLS OVER 10' SHALL BE LATERALLY BRACED AT 4' O.C. CONTRACTOR SHALL VERIFY ALL POINT LOADS ARE SUPPORTED TO THE FOUNDATION. FLOORING AND ROOFING: PLYWOOD SUBFLOORING SHALL BE 4" T&G CDX GLUED AND NAILED. NAILING SHALL BE 8d @ 6" O.C. ALONG PANEL EDGES, AND 12" O.C. IN FIELD. STAGGER END LAPS. ROOF SHEATHING SHALL BE 2" CDX OR 16" OSB NAILED WITH 8d @ 6" O.C. ALONG PANEL EDGES AND 12" O.C. IN THE FIELD. STAGGER END LAPS. FRAMING LUMBER (MANUFACTURED): SHALL BE MANUFACTURED BY THE FOLLOWING MANUFACTURERS IN ACCORDANCE WITH APPROVED SHOP AND INSTALLATION DRAWINGS. APPROVED MANUFACTURERS SPECIFIED MATERIAL PRESERVATIVE CONNECTORS & BLOCKING BETWEEN CEILING JOISTS, TOENAIL, EACH END TREATMENT (1) SPECIFIED TRUS-JOIST BOISE CASCADE LOUISIANA ROSEBURG FOREST GEORGIA MEMBER SBX GALV (G60) PACIFIC PRODUCTS PACIFIC AND WEB FILLER 2x TIMBERSTRAND (L/240 L.L.) 2x GANGLAM GALV (G185) MASONRY WALLS (4) CEILING JOIST NOT ATTACHED TO Fb=1700 PSI (3) 16d Fb=2250 PSI 2X, & 4X (FIR) ACQ, CBA, CA 2x SCL E=1300 KSI MEMBER E=1500 KSI FACE NAIL 2X, & 4X (CEDAR) NONE Fv=400 PSI POSTS & LEDGERS Fv=275 PSI 6X OR GLULAM (FIR) ACQ, CBA, CA GALV (G185) 1-3/4" PARALLAM 1-3/4" VERSALAM 1-3/4" LP LVL 1-3/4" RIGID -LAM 1-3/4" G -P -LAM 1-3/4" SCL Fb=2900 PSI Fb=2800 PSI Fb=2950 PSI Fb=2900 PSI Fb=3100 PSI RAFTERS, OR RAFTER TO 2" RIDGE E=2000 KSI E=2000 KSI E=2000 KSI E=2000 KSI E=2000 KSI (NOT AT BRACED WALL PANELS) Fv=290 PSI Fv=285 PSI Fv=290 PSI Fv=285 PSI Fv=285 PSI AT INTERSECTING WALL CORNERS 3-1/2" PARALLAM 3-1/2" VERSALAM 3-1/2" LP LVL 3-1/2" RIGID -LAM 2 -PLY G -P -LAM* 3-1/2" SCL Fb=2900 PSI Fb=3100 PSI Fb=2950 PSI Fb=2900 PSI Fb=3100 PSI TOP PLATE TO TOP PLATE E=2000 KSI E=2000 KSI E=2000 KSI E=2000 KSI E=2000 KSI AT END JOINTS Fv=290 PSI Fv=285 PSI Fv=290 PSI Fv=285 PSI Fv=285 PSI BAND JOIST (NOT AT BRACED PANEL) 5-1/4" PARALLAM 5-1/4" VERSALAM 5-1/4" LP LVL 5-1/4" RIGID -LAM 3 -PLY G -P -LAM* 5-1/4" SCL Fb=2900 PSI Fb=3100 PSI Fb=2950 PSI Fb=2900 PSI Fb=3100 PSI STUD TO TOP OR BOTTOM PLATE E=2000 KSI E=2000 KSI E=2000 KSI E=2000 KSI E=2000 KSI TOP PLATES, LAPS AT CORNERS AND Fv=290 PSI Fv=285 PSI Fv=290 PSI Fv=285 PSI Fv=285 PSI JOIST TO STILL, TOP PLATE OR 7" PARALLAM 7" VERSALAM 7" LP LVL 7" RIGID -LAM 4 -PLY G -P -LAM* RIM JOIST/BAND JOIST OR BLOCKING Fb=2900 PSI Fb=3100 PSI Fb=2950 PSI Fb=2900 PSI Fb=3100 PSI 7" SCL E=2000 KSI E=2000 KSI E=2000 KSI E=2000 KSI E=2000 KSI (PLANK & BEAM - FLOOR & ROOF) Fv=290 PSI Fv=285 PSI Fv=290 PSI Fv=285 PSI Fv=285 PSI RIM BOARD OR APA / EWS PERFORMANCE RATED RIM (PRR-401) 1-1/8" MINIMUM THICKNESS RIM JOIST LEDGER STRIP SUPPORTING JOISTS * - CONNECT MULTI -PLY MEMBERS PER MANUFACTURER'S RECOMMENDATIONS - LSL's MAY BE USED IN PLACE OF LVL's WHEN SPECIFIED - PRESERVATIVE TREATED WOOD REQUIREMENTS: IBC 2304.12: WOOD JOISTS OR THE BOTTOM OF A WOOD STRUCTURAL FLOOR WITHOUT JOISTS SHALL NOT BE CLOSER THAN 18 INCHES, OR WOOD GIRDERS CLOSER THAN 12 INCHES TO THE EXPOSED GROUND IN CRAWL SPACES. WOOD FRAMING MEMBERS, INCLUDING WOOD SHEATHING, WHICH REST ON EXTERIOR FOUNDATION WALLS SHALL NOT BE LESS THAN 8 INCHES FROM EXPOSED EARTH. SILLS IN CONTACT WITH CONCRETE SHALL BE PRESERVATIVE -TREATED WOOD. CLEARANCE BETWEEN WOOD SIDING AND EARTH SHALL NOT BE LESS THAN 6 INCHES. POSTS SHALL BE PRESERVATIVE -TREATED UNLESS SUPPORTED BY A PEDESTAL GREATER THAN 8 INCHES FROM EXPOSED GROUND. w 0 APPLICATION SPECIFIED MATERIAL PRESERVATIVE CONNECTORS & BLOCKING BETWEEN CEILING JOISTS, TOENAIL, EACH END TREATMENT (1) FASTENERS (2)(3) FOUNDATION SILL (20# L.L.) BLOCKING AT RAFTERS/TRUSS NOT TOENAIL, EACH END PLATES, TOP PLATES & 2X, 4X, 6X OR GLULAM SBX GALV (G60) LEDGERS ON (FIR) 16d @ 6" O.C. AND WEB FILLER CONCRETE OR (L/240 L.L.) ACQ, CBA, CA GALV (G185) MASONRY WALLS (4) CEILING JOIST NOT ATTACHED TO FACE NAIL (3) 16d PARALLEL RAFTER, LAPS OVER PARTITION 2X, & 4X (FIR) ACQ, CBA, CA GALV (G185) FRAMING, DECKING, MEMBER PARALLEL RAFTER (HEEL JOINT) FACE NAIL 2X, & 4X (CEDAR) NONE GALV (G90) POSTS & LEDGERS RAFTER OR ROOF TRUSS TO TOP 6X OR GLULAM (FIR) ACQ, CBA, CA GALV (G185) BEAMS AND COLUMNS 6X OR GLULAM RAFTERS TO RIDGE VALLEY/ HIP END NAIL (2)16d (CEDAR) NONE GALV (G90) PRESERVATIVE TREATED WOOD FASTENER REQUIREMENTS: ALL METAL CONNECTORS COMING IN CONTACT WITH PRESSURE TREATED WOOD SHALL BE SIMPSON Z -MAX, TRIPLE ZINC COATED, OR HOT DIPPED GALVANIZED. CCA: CHROMATED COPPER ARSENATE NOT PERMITTED. SBX: DOT SODIUM BORATE ACQ: ALKALINE COPPER QUAT CBA AND CA: COPPER AZOLE G60, G90, AND G185 PER ASTM A23 FOR CONNECTORS, AND ASTM A153 FOR FASTENERS. MECHANICALLY GALVANIZED FASTENERS PER ASTM B695, CLASS 55 OR GREATER. GENERAL CARPENTRY NOTES: STAGGER ALL NAILING TO PREVENT SPLITTING OF WOOD MEMBERS. PRESSURE -TREAT ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY. HOLES AND CUTS IN PLATES SHOULD BE TREATED WITH A 20% SOLUTION OF COPPER NAPHTHENATE. BOLT HOLES IN WOOD MEMBERS SHALL BE A MINIMUM OF 1/32" TO A MAXIMUM OF 1/16" LARGER THAN THE BOLT DIAMETER. PROVIDE CUT WASHERS WHERE BOLT HEADS, NUTS AND LAG SCREW HEADS BEAR ON WOOD. PROVIDE A MINIMUM 3x3x.229 PLATE WASHER ON ALL ANCHOR BOLTS WHICH CONNECT MUD SILLS TO FOUNDATION. DO NOT NOTCH OR DRILL STRUCTURAL MEMBERS. REFER TO PRESERVATIVE TREATED WOOD REQUIREMENTS TABLE FOR GALVANIZING REQUIREMENTS FOR CONNECTORS AND FASTENERS. USE DOUBLE JOISTS UNDER ALL PARALLEL PARTITIONS THAT EXTEND MORE THAN 2 THE LENGTH AND AROUND OPENINGS UNLESS DESIGNED BY A FLOOR JOIST MANUFACTURER. POSITIVE CONNECTIONS SHALL BE PROVIDED AT POST -BEAM CONNECTIONS TO ENSURE AGAINST UPLIFT AND LATERAL DISPLACEMENT. USE 12" CS -14 UNLESS NOTED OTHERWISE. FASTENING SCHEDULE FOR WOOD STRUCTURAL MEMBERS IBC 2304.10.1 ITEM TYPE CONNECTION BLOCKING BETWEEN CEILING JOISTS, TOENAIL, EACH END (3) 8d RAFTERS/TRUSSES TO TOP PLATE (40# L.L.) (20# L.L.) BLOCKING AT RAFTERS/TRUSS NOT TOENAIL, EACH END (2) 8d AT WALL TOP PLATE/RAFTER/TRUSS � FLAT BLOCKING TO TRUSS FACE NAIL 16d @ 6" O.C. AND WEB FILLER (L/360 L.L.) (L/240 L.L.) CEILING JOISTS TO TOP PLATE TOENAIL, EACH JOIST (3) 8d CEILING JOIST NOT ATTACHED TO FACE NAIL (3) 16d PARALLEL RAFTER, LAPS OVER PARTITION NO.2 H.F. SPACING O.C. CEILING JOIST ATTACHED TO MAXIMUM MEMBER PARALLEL RAFTER (HEEL JOINT) FACE NAIL PER TABLE 2308.7.3.1 COLLAR TIE TO RAFTER FACE NAIL (3)10d RAFTER OR ROOF TRUSS TO TOP TOENAIL (3)10d PLATE 14'-10" RAFTERS TO RIDGE VALLEY/ HIP END NAIL (2)16d RAFTERS, OR RAFTER TO 2" RIDGE 16" 9'-1" RAFTERS TO RIDGE VALLEY/ HIP TOENAIL (3)10d RAFTERS, OR RAFTER TO 2" RIDGE 1'-9 1Q " STUD TO STUD 7'-11" 10'-5" (NOT AT BRACED WALL PANELS) FACE NAIL 16d @ 24" O.C. STUD TO STUD AND ABUTTING STUDS FACE NAIL 16d @ 16" O.C. AT INTERSECTING WALL CORNERS 18'-8" BUILT-UP HEADER FACE NAIL, EACH EDGE 16d @ 16" O.C. (2" TO 2" HEADER) 16" 12'-0"16'-2" CONTINUOUS HEADER TO STUD TOENAIL (4) 8d TOP PLATE TO TOP PLATE FACE NAIL 16d @ 16" O.C. TOP PLATE TO TOP PLATE, END JOINT, FACE NAIL (8)16d, EACH SIDE END JOINT, AT END JOINTS 2 4" FACE NAIL (M IN 24" LAP SPLICE) BOTTOM PLATE TO JOIST/RIM JOIST/ 12" BAND JOIST (NOT AT BRACED PANEL) FACE NAIL 16d @ 16" O.C. BOTTOM PLATE TO JOIST/RIM JOIST/ FACE NAIL (2) 16d @ 16" O.C. BAND JOIST AT BRACED PANEL 16" 15'-2" STUD TO TOP OR BOTTOM PLATE TOENAIL (4) 8d STUD TO TOP OR BOTTOM PLATE END NAIL (2)16d TOP OR BOTTOM PLATE STUD END NAIL (2)16d TOP PLATES, LAPS AT CORNERS AND FACE NAIL (2)16d INTERSECTIONS 12" JOIST TO STILL, TOP PLATE OR TOENAIL (3) 8d GIRDER 21'-9" 241-411 RIM JOIST/BAND JOIST OR BLOCKING 16" 17'-7" TO TOP PLATE/SILL/FRAMING BELOW TOENAIL 8d @ 6" O.C. 2" SUBFLOOR TO JOIST OR GIRDER FACE NAIL (2)16d 2" PLANKS FACE NAIL, EACH BEARING (2)16d (PLANK & BEAM - FLOOR & ROOF) 2411 15'-5" BUILT-UP GIRDERS AND BEAMS FACE NAIL AT TOP AND BOTTOM 20d @ 32" O.C. 2 LUMBER LAYERS STAGGERED ON OPPOSITE SIDES LEDGER STRIP SUPPORTING JOISTS FACE NAIL, EACH JOIST OR RAFTER (3)16d OR RAFTERS JOIST TO BAND/RIM JOIST END NAIL (3)16d BRIDGING/BLOCKING TO TOENAIL, EACH END (2) 8d JOIST, RAFTER OR TRUSS CONNECTIONS ARE COMMON NAILS U.N.O LAG SCREWS: SHALL BE OF A DIAMETER INDICATED ON DRAWINGS WITH A MINIMUM OF 8x DIAMETER EMBEDMENT IN SUPPORTING MEMBER UNLESS NOTED OTHERWISE. CLEARANCE HOLE FOR THE SHANK SHALL BE THE SAME DIAMETER AS THE SHANK AND THE SAME DEPTH OF PENETRATION AS THE UNTHREADED PORTION OF THE SHANK. THE LEAD HOLE FOR THE THREADED PORTION SHALL HAVE A DIAMETER EQUAL TO 60 TO 75% OF THE SHANK DIAMETER AND A LENGTH EQUAL TO AT LEAST THE LENGTH OF THE THREADED PORTION. THE THREADED PORTION OF THE SCREW SHALL BE INSERTED IN ITS LEAD HOLE BY TURNING WITH A WRENCH, NOT BY DRIVING WITH A HAMMER. SOAP OR OTHER LUBRICANT SHALL BE USED ON THE SCREWS OR IN THE LEAD HOLE TO FACILITATE INSERTION AND TO PREVENT DAMAGE TO THE SCREW. METAL PLATE CONNECTED WOOD TRUSSES: SHALL BE MANUFACTURED BY AN APPROVED TRUSS MANUFACTURER IN ACCORDANCE WITH APPROVED SHOP AND INSTALLATION DRAWINGS. ALL ROOF TRUSSES ARE TO BE PRE-ENGINEERED BY OTHERS. ROOF TRUSSES SHALL BE PROVIDED TO COMPLETE THE ROOF FRAMING FROM THE SHEATHING TO THE SUPPORTING MEMBERS BELOW. SHOP DRAWINGS AND CALCULATIONS SHALL BE PRODUCED UNDER THE SUPERVISION OF A PROFESSIONAL ENGINEER REGISTERED IN THE STATE WASHINGTON. DETAIL DRAWINGS TO INDICATE ALL INFORMATION AS REQUIRED IN IRC SECTION R802.10.1 INCLUDING PERMANENT LATERAL BRACING AND CONNECTION DETAILS. -JOISTS: SHALL BE APA EWS PERFORMANCE RATED I -JOISTS (PRI). I -JOISTS SHALL BE MANUFACTURED IN CONFORMANCE WITH APA PRI -400 CONFORMING TO APPROVED SHOP AND INSTALLATION DRAWINGS. SPAN TABLE IRC R802.5.1(3) FLOOR CEILING M JOISTS (10# D.L.) (40# L.L.) (20# L.L.) RAFTERS (30# L.L.) TILE COMP/SHAKE Mft � (L/240 L.L.) (20# D.L.) (10# D.L.) L4 u (L/360 L.L.) (L/240 L.L.) NO.2 H.F. SPACING O.C. MAXIMUM MAXIMUM NO.2 H.F. SPACING O.C. MAXIMUM MAXIMUM MEMBER SPAN SPAN MEMBER SPAN SPAN 12" 10' 14'-10" 12" 12'-2" 13'-7" 2 X 6 16" 9'-1" 12'-10" 2 X 6 16" 1Q0'-6" 1'-9 1Q " 24" 7'-11" 10'-5" 24" 8'-7" 9'-7" 12" 13'-2" 18'-8" 12" 15'-4" 17'-2" 2 X 8 16" 12'-0"16'-2" 2 X 8 16" 13'-4" 14'-11" 2 4" 10'-2" 13'-2" 2 4" 10'-10" 12'-2" 12" 16'-10" 22'-11" 12" 18'-9" 21'-0" 2 X 10 16" 15'-2" 19'-10" 2 X 10 16" 16'-3" 18'-2" 2411 12'-5" 16'-2" 2411 13'-3" 14'-10" 12" 201-411 261-711 12" 21'-9" 241-411 2 X 12 16" 17'-7" 23'-0" 2 X 12 16" 18'-10" 21'-1" 2411 14'-4" 18'-10" 2411 15'-5" 17'-3" L N c N O Z - fii •L N ya) O N O cLU 'a) w �c�Q���o f6um L_Cr oco �J a >��ooc�. f6 N y V �-r--� -E O V C 0 0 c'aZ�°oa)�>, T= ~ a) a) U L L U c Tui+, H �1�a)ZO>.ca) c o 0 c N c CL t yzQ U N � Na U N NE cM-0=Q UU cn N a) O % �2?E2C 2 Baa)) cn �_0 v a y Q: M 41 O LnLn� Q � Mft � L4 u J � Ica m Q BUILDING CODE 2015 I5C WIND EXP. 5 110 MPH SEISMIC DESIGN CATEGORY D ROOF SNOW LOAD 25 F5F fE . P.E. JOIN N. o 121221 REVIEW ZACK C. ANALYST ALEC H. SHEET 5 OF 5 SHEETS PROJECT NUMBER 200691 COPYRIGHT Q2020 I-IODCxE ENGINEERING, INC D Y Ub4G 196-23-D�0 WITH A GLOBAL SIGN CERTIFICATE. TI$ GERIIFICATE MAY SE I�EhIOVID SY T4� JLp215DICTION