2021.0009 16404 CalculationsPage 1 of 68 TABLE OF CONTENTS Project and Site Information ........................................................................................................... -Engineering Methods Explanation (2015 IBC Lateral and Gravity Engineering Calculations Package For Plans Examiner) - Wind Speed Determination - Applied Technology Council - Seismic1 Spectral Response - Applied Technology Council - Satellite Image of Building Site and Surrounding Area - Snow Load Calculation (with Normalized Ground Snow Load Chart if Over 30 psf) Lateral Analysis ................................................................................................................................ -Project Lateral Information - Design Settings and Site Information -Woodworks® Shearwall Lateral Analysis - Layout and Uplift by Floor -Design Summary - Shear Wall Design and Hold Downs -Shear Results for Wind - Critical Response Summary -Shear Results for Seismic - Critical Response Summary -Simpson Strong Wall Design Criteria and Anchorage Calculations (if specified) -Plan Specific Lateral Items Gravity Load Analysis ..................................................................................................................... -Forte® Job Summary Report - List of Beams and Headers -Member Reports - Individual Beams and Headers -Post Capacities Tables -Plan Specific Gravity Items Foundation ........................................................................................................................................ -1500 PSF Reinforced Concrete Pad Calculations -Continuous Concrete Footing with Stem Point Load Engineering -Restrained Retaining Walls if Present -Unrestrained Retaining Walls if Present -Plan Specific Foundation Items 1 2015 International Building Code (IBC) Page 2 of 68 2015 IBC Lateral and Gravity Engineering Calculations Package For Plans Examiner This engineering calculations package contains the lateral and gravity load engineering as noted in the engineering scope. All engineered load bearing structural members are specified on the full size engineering sheets. The enclosed engineering calculations document the engineering analysis. The engineering calculations are not required to be referenced onsite for construction. These calculations are to demonstrate to the Plans Examiner that the engineering was completed following the 2015 IBC. The cover sheet of the engineering specifies the engineering scope as lateral and gravity load engineering. LATERAL ENGINEERING: Lateral engineering involves determining what the seismic and wind loads are according to ASCE 7-10. Applying these loads to the structure, and determining the design of the lateral structural elements to resist these loads. The structural elements are sheathing, nailing, holdowns, and the connections between loaded members and shear resisting elements. Lateral load modeling was completed with Wood Works Design Office 10 (www.woodworks- software.com 800-844-1275). Wood Works was developed in conjunction with the American Forest & Paper Association. The AF&PA is the same professional organization that produces the National Design Specification (NDS) for Wood Construction, the Allowable Stress Design (ASD) manual for engineered wood construction, Wood Frame Construction Manual (WFCM) for one-and two-family dwellings, and the Load and Resistance Factor Design (LFRD) manual for engineered wood construction. The AF&PA "wrote the manuals" all engineers use. Seismic: Seismic load engineering follows the ASCE 7-10 12.8 equivalent lateral force procedure. Per ASCE 7 the analysis consists of the application of equivalent static lateral forces to a linear mathematical model of the structure. The total forces applied in each direction are the total base shear. Refer to ASCE 7-10 12.8 for a detailed description of this procedure. The engineering calculations include a USGS determination of the seismic spectral response accelerations. These numbers, S1 and Ss, are used in the lateral model to determine seismic loading to the shearwalls. Woodworks Design Office was used to make the linear mathematical model specified by ASCE 7-10 section 12.8. Wind: Wind load engineering follows the ASCE 7-10 Directional method for all heights. The wind loading is determined from the wind exposure and wind speed. This loading is applied to surfaces of the structure as modeled. Total loadings for each shear line, wall line, and full height shearwall are determined. Required shear strengths for each shearwall are calculated then sheathing and nailing patterns are chosen to resist design loads. Holdowns are applied where the nailing of the OSB sheathing to the mudsill or lower floor is not adequate to resist shear panel overturning. GRAVITY LOAD ENGINEERING: Gravity loads from snow, structure, occupants, etc. meeting the requirements of the 2015 IBC have been traced through the structure. Refer to the legend on the engineering sheets showing how the point and line loads are depicted. All loads are supported and traced through the structure. Load supporting members have been numbered for reference back to the engineering calculations. Loads to the foundation or soil have reinforced footings specified where required. Page 3 of 68 Page 4 of 68 Hodge Engineering, Inc. John E. Hodge P. E. 3733 Rosedale St, Suite 200, Gig Harbor, WA 98335 (253) 857-7055 Snow Loading Calculation Site: Parcel# 64303500503, Yelm, WA 98587 Plan: Yelm Job: 200691 Three resources for determining snow load: 1. Snow Load Analysis for Washington; 2nd Edition by the Structural Engineers Association of Washington (SEAW). “This edition provides a large color map for each half of the state, with normalized ground snow load isolines and elevation contours to help readily determine the ground snow load anywhere in the state”. 2. WABO/SEAW White Paper #8 “Guidelines for Determining Snow Loads in Washington State” available on www.seaw.org/publications 3. ASCE 7-10 Chapter 7 Snow Loads Ground Snow Load pg: (ASCE 7-10 7.2 Extreme value statistical analysis using 2% annual probability of being exceeded) Normalized ground snow load (NGSL) = 0.050 Lot Elevation = 350 ft. from Google Earth 1. Ground snow load = NGSL x elevation = 0.050 * 350 = 18 psf = pg 2. SEAW Snow Load Analysis for Washington Appendix A = 18 psf (@340 FT) Roof Snow Load pf: ASCE 7-10 7.3 Flat roof snow load pf = 0.7CeCtIpg ASCE 7-10 7.3.1 Ce is the exposure factor = 1.0 for partially exposed structure (table 7.2) ASCE 7-10 7.3.2 Ct is the thermal factor = 1.1 for heated residences (table 7.3) ASCE 7-10 7.3.3 I is the importance factor = 1.0 for residences (table 1.5-2) ASCE 7-10 7.4 Sloped roof snow loads - no roof slope reduction Cs taken ASCE 7-10 7.6 Trussed roof or slope exceeding 7:12 – no unbalanced snow loading pf = 0.7CeCtIpg = 0.7 * 1.0 * 1.1 * 1.0 * 18 pg = 14 psf Use minimum roof snow load 25 psf. “Snow load to be approved by the authority having jurisdiction…” ASCE 7-10 7.2 Page 5 of 68 WoodWorks® Shearwalls SOFTWARE FOR WOOD DESIGN WoodWorks® Shearwalls 11.1 200691 - Lateral Analysis.wsw Jan. 25, 2021 13:51:04 Project Information COMPANY AND PROJECT INFORMATION Company Project HODGE ENGINEERING 2615 JAHN AVE NW SUITE E5 GIG HARBOR, WA 98335 DESIGN SETTINGS Design Code IBC 2015/AWC SDPWS 2015 Wind Standard ASCE 7-10 Directional (All heights) Seismic Standard ASCE 7-10 Load Combinations For Design (ASD) 0.70 Seismic 0.60 Wind For Deflection (Strength) 1.00 Seismic 1.00 Wind Building Code Capacity Modification Wind Seismic 1.00 1.00 Service Conditions and Load Duration Duration Factor 1.60 Temperature Range T<=100F Moisture Content Fabrication Service 19% <=19%10% <=19% Max Shearwall Offset [ft] Plan (within story) 4.00 Elevation (between stories) 4.00 Maximum Height-to-width Ratio Wood panels Wind Seismic Fiberboard Lumber Wind Seismic Gypsum Blocked Unblocked 3.5 3.5 - - - - - Ignore non-wood-panel shear resistance contribution... Wind Seismic when comb'd w/ wood panels Always Collector forces based on... Hold-downs Applied loads Drag struts Applied loads Shearwall Relative Rigidity: Wall capacity Perforated shearwall Co factor: SDPWS Equation 4.3-5 Non-identical materials and construction on the shearline: Not allowed Deflection Equation: 3-term from SDPWS 4.2-1 Drift limit for wind design: 1 / 500 story height SITE INFORMATION Risk Category Category II - All others Wind ASCE 7-10 Directional (All heights) Seismic ASCE 7-10 12.8 Equivalent Lateral Force Procedure Design Wind Speed 110 mph Exposure Exposure B Enclosure Enclosed Structure Type Irregular Building System Bearing Wall Design Category D Site Class D Topographic Information [ft] Shape - Height - Length - Site Location: - Elev: 350ft Avg Air density: 0.0757 lb/cu ft Rigid building - Static analysis Spectral Response Acceleration S1: 0.500g Ss: 1.250g Fundamental Period E-W N-S T Used 0.194s 0.194s Approximate Ta 0.194s 0.194s Maximum T 0.272s 0.272s Response Factor R 6.50 6.50 Fa: 1.00 Fv: 1.50 Case 2 N-S loadsE-W loads Eccentricity (%)15 15 Loaded at 75% Min Wind Loads: Walls Roofs 16 psf 8 psf Serviceability Wind Speed 85 mph 1 Page 6 of 68 WoodWorks® Shearwalls SOFTWARE FOR WOOD DESIGN WoodWorks® Shearwalls 11.1200691 - Lateral Analysis.wsw Jan. 4, 2021 09:38:12 0'1' 8"3' 4"5'6' 8"8' 4"10'11' 8"13' 4"15'16' 8"18' 4"20'21' 8"23' 4"25'26' 8"28' 4"30'31' 8"33' 4"35'36' 8"38' 4"40'41' 8"43' 4"45'46' 8" -6' 8" -5' -3' 4" -1' 8" 0' 1' 8" 3' 4" 5' 6' 8" 8' 4" 10' 11' 8" 13' 4" 15' 16' 8" 18' 4" 20' 21' 8" 23' 4" 25' 26' 8" 28' 4" 30' 31' 8" 33' 4" 35' 36' 8" 38' 4" 40' 41' 8" E-1 2-1B-11-11347 7137017097137017091347 95892795892713475345341347586541586541Loads: Seismic (Qe); Forces: 0.7E + 0.6D; E = pQe + 0.2 Sds D; p(NS) = 1.0; p(EW) = 1.0; Sds = 0.83; Flexible distribution Vertical element required C Compression force exists Factored holddown force (lbs) Factored shearline force (lbs) Applied point load or discontinuous shearline force (lbs) Unfactored dead load (plf,lbs) Unfactored applied shear load (plf) Level 2 of 2 Page 7 of 68 WoodWorks® Shearwalls SOFTWARE FOR WOOD DESIGN WoodWorks® Shearwalls 11.1200691 - Lateral Analysis.wsw Jan. 4, 2021 09:38:12 0'1' 8"3' 4"5'6' 8"8' 4"10'11' 8"13' 4"15'16' 8"18' 4"20'21' 8"23' 4"25'26' 8"28' 4"30'31' 8"33' 4"35'36' 8"38' 4"40'41' 8"43' 4"45'46' 8" -6' 8" -5' -3' 4" -1' 8" 0' 1' 8" 3' 4" 5' 6' 8" 8' 4" 10' 11' 8" 13' 4" 15' 16' 8" 18' 4" 20' 21' 8" 23' 4" 25' 26' 8" 28' 4" 30' 31' 8" 33' 4" 35' 36' 8" 38' 4" 40' 41' 8" E-1 2-1B-11-112771277676664672676664672127712779088799088791243124349349312431243540499540499 Loads: Directional Case 1 Wind (W); Forces: 0.6W + 0.6D; Flexible distribution Vertical element required C Compression force exists Factored holddown force (lbs) Factored shearline force (lbs) Applied point load or discontinuous shearline force (lbs) Unfactored uplift wind load (plf,lbs) Unfactored dead load (plf,lbs) Unfactored applied shear load (plf) Level 2 of 2 Page 8 of 68 WoodWorks® Shearwalls SOFTWARE FOR WOOD DESIGN WoodWorks® Shearwalls 11.1200691 - Lateral Analysis.wsw Jan. 4, 2021 09:38:12 0'1' 8"3' 4"5'6' 8"8' 4"10'11' 8"13' 4"15'16' 8"18' 4"20'21' 8"23' 4"25'26' 8"28' 4"30'31' 8"33' 4"35'36' 8"38' 4"40'41' 8"43' 4"45'46' 8" -6' 8" -5' -3' 4" -1' 8" 0' 1' 8" 3' 4" 5' 6' 8" 8' 4" 10' 11' 8" 13' 4" 15' 16' 8" 18' 4" 20' 21' 8" 23' 4" 25' 26' 8" 28' 4" 30' 31' 8" 33' 4" 35' 36' 8" 38' 4" 40' 41' 8" E-1 4-1A-11-1B-1 2-12-3C-1 D-1 3-12-234950750750750723377011779701154224822073215622757264944943216856851604209920312099203120076431054117752022135865415805725861119580115854157867310721072444241241 Loads: Seismic (Qe); Forces: 0.7E + 0.6D; E = pQe + 0.2 Sds D; p(NS) = 1.0; p(EW) = 1.0; Sds = 0.83; Flexible distribution Vertical element required C Compression force exists Factored holddown force (lbs) Factored shearline force (lbs) Applied point load or discontinuous shearline force (lbs) Unfactored dead load (plf,lbs) Unfactored applied shear load (plf) Level 1 of 2 Page 9 of 68 WoodWorks® Shearwalls SOFTWARE FOR WOOD DESIGN WoodWorks® Shearwalls 11.1200691 - Lateral Analysis.wsw Jan. 4, 2021 09:38:12 0'1' 8"3' 4"5'6' 8"8' 4"10'11' 8"13' 4"15'16' 8"18' 4"20'21' 8"23' 4"25'26' 8"28' 4"30'31' 8"33' 4"35'36' 8"38' 4"40'41' 8"43' 4"45'46' 8" -6' 8" -5' -3' 4" -1' 8" 0' 1' 8" 3' 4" 5' 6' 8" 8' 4" 10' 11' 8" 13' 4" 15' 16' 8" 18' 4" 20' 21' 8" 23' 4" 25' 26' 8" 28' 4" 30' 31' 8" 33' 4" 35' 36' 8" 38' 4" 40' 41' 8" E-1 4-1A-11-1B-1 2-12-3C-1 D-1 3-12-227640140137037026986641967664182427192135226323781368932835778166016401701170121182049211820492689861119012856413039540499797785540129374812784997461019101916231623608608330330 Loads: Directional Case 1 Wind (W); Forces: 0.6W + 0.6D; Flexible distribution Vertical element required C Compression force exists Factored holddown force (lbs) Factored shearline force (lbs) Applied point load or discontinuous shearline force (lbs) Unfactored uplift wind load (plf,lbs) Unfactored dead load (plf,lbs) Unfactored applied shear load (plf) Level 1 of 2 Page 10 of 68 WoodWorks® Shearwalls 200691 - Lateral Analysis.wsw Jan. 25, 2021 13:51:04 Structural Data STORY INFORMATION Hold-down Story Floor/Ceiling Wall Length subject to Bolt Elev [ft]Depth [in]Height [ft]shrinkage [in]length [in] Ceiling 20.00 0.0 Level 2 12.00 12.0 8.00 15.5 16.5 Level 1 3.00 12.0 8.00 15.5 16.5 Foundation 2.00 BLOCK and ROOF INFORMATION Block Roof Panels Dimensions [ft]Face Type Slope Overhang [ft] Block 1 2 Story E-W Ridge Location X,Y =0.00 8.00 North Side 26.6 2.00 Extent X,Y =24.00 30.00 South Side 26.6 2.00 Ridge Y Location, Offset 23.00 0.00 East Gable 90.0 2.00 Ridge Elevation, Height 27.50 7.50 West Gable 90.0 2.00 Block 2 1 Story E-W Ridge Location X,Y =24.00 0.00 North Side 26.6 2.00 Extent X,Y =8.00 29.00 South Side 26.6 2.00 Ridge Y Location, Offset 14.50 0.00 East Gable 90.0 2.00 Ridge Elevation, Height 19.50 7.50 West Joined 90.0 2.00 Block 3 1 Story E-W Ridge Location X,Y =32.00 0.00 North Side 26.6 2.00 Extent X,Y =12.00 22.00 South Side 26.6 2.00 Ridge Y Location, Offset 11.00 0.00 East Gable 90.0 2.00 Ridge Elevation, Height 17.50 5.50 West Joined 90.0 2.00 Block 4 1 Story E-W Ridge Location X,Y =0.00 4.00 North Side 90.0 2.00 Extent X,Y =24.00 4.00 South Side 26.6 2.00 Ridge Y Location, Offset 8.00 2.00 East Joined 90.0 2.00 Ridge Elevation, Height 14.00 2.00 West Gable 90.0 2.00 2 Page 11 of 68 WoodWorks® Shearwalls 200691 - Lateral Analysis.wsw Jan. 25, 2021 13:51:04 SHEATHING MATERIALS by WALL GROUP Sheathing Fasteners Apply Grp Surf Material Ratng Thick GU Ply Or Gvtv Size Type Df Eg Fd Bk Notes in in lbs/in in in 1 Ext Struct Sh OSB 24/16 7/16 -3 Vert 83500 8d Nail N 6 12 Y 1,3 Legend: Grp – Wall Design Group number, used to reference wall in other tables Surf – Exterior or interior surface when applied to exterior wall Ratng – Span rating, see SDPWS Table C4.2.2.2C Thick – Nominal panel thickness GU - Gypsum underlay thickness Ply – Number of plies (or layers) in construction of plywood sheets Or – Orientation of longer dimension of sheathing panels Gvtv – Shear stiffness in lb/in. of depth from SDPWS Tables C4.2.2A-B Type – Fastener type from SDPWS Tables 4.3A-D: Nail – common wire nail for structural panels and lumber, cooler or gypsum wallboard nail for GWB, plasterboard nail for gypsum lath, galvanised nail for gypsum sheathing; Box - box nail; Casing – casing nail; Roof – roofing nail; Screw – drywall screw Size - Common, box, and casing nails: refer to SDPWS Table A1 (casing sizes = box sizes). Gauges: 11 ga = 0.120” x 1-3/4” (gypsum sheathing, 25/32” fiberboard ), 1-1/2” (lath & plaster, 1/2” fiberboard); 13 ga plasterboard = 0.92” x 1- 1/8”. Cooler or gypsum wallboard nail: 5d = .086” x 1-5/8”; 6d = .092” x 1-7/8”; 8d = .113” x 2-3/8”; 6/8d = 6d base ply, 8d face ply for 2-ply GWB. Drywall screws: No. 6, 1-1/4” long. 5/8” gypsum sheathing can also use 6d cooler or GWB nail Df – Deformed nails ( threaded or spiral), with increased withdrawal capacity Eg – Panel edge fastener spacing Fd – Field spacing interior to panels Bk – Sheathing is nailed to blocking at all panel edges; Y(es) or N(o) Apply Notes – Notes below table legend which apply to sheathing side Notes: 1.Capacity has been reduced for framing specific gravity according to SDPWS T4.3A Note 3. 3. Shear capacity for current design has been increased to the value for 15/32" sheathing with same nailing because stud spacing is 16" max. or panel orientation is horizontal. See SDPWS T4.3A Note 2. FRAMING MATERIALS and STANDARD WALL by WALL GROUP Wall Species Grade b d Spcg SG E Standard Wall Grp in in in psi^6 1 Hem-Fir No.2 1.50 6.00 16 0.43 1.30 Legend: Wall Grp – Wall Design Group b – Stud breadth (thickness) d – Stud depth (width) Spcg – Maximum on-centre spacing of studs for design, actual spacing may be less. SG – Specific gravity E – Modulus of elasticity Standard Wall - Standard wall designed as group. Notes: Check manufacture requirements for stud size, grade and specific gravity (G) for all shearwall hold-downs. 3 Page 12 of 68 WoodWorks® Shearwalls 200691 - Lateral Analysis.wsw Jan. 25, 2021 13:51:04 SHEARLINE, WALL and OPENING DIMENSIONS North-south Type Wall Location Extent [ft]Length FHS Aspect Height Shearlines Group X [ft]Start End [ft] [ft] Ratio [ft] Line 1 Level 2 Line 1 Seg 1 0.00 8.00 38.00 30.00 30.00 - 8.00 Wall 1-1 Seg 1 0.00 8.00 38.00 30.00 30.00 0.27 - Level 1 Line 1 1 0.00 8.00 38.00 30.00 26.00 - 8.00 Wall 1-1 Seg 1 0.00 8.00 38.00 30.00 26.00 - - Segment 1 -- 8.00 31.00 23.00 - 0.35 - Opening 1 -- 31.00 35.00 4.00 - - 8.00 Segment 2 -- 35.00 38.00 3.00 - 2.67 - Line 2 Level 2 Line 2 1 24.00 8.00 38.00 30.00 28.00 - 8.00 Wall 2-1 Seg 1 24.00 8.00 38.00 30.00 28.00 - - Segment 1 -- 8.00 24.00 16.00 - 0.50 - Opening 1 -- 24.00 26.00 2.00 - - 8.00 Segment 2 -- 26.00 38.00 12.00 - 0.67 - Level 1 Line 2 1 24.00 0.00 38.00 38.00 31.50 - 8.00 Wall 2-1 Seg 1 24.00 0.00 8.00 8.00 8.00 1.00 - Wall 2-2 Seg 1 24.00 8.00 22.50 14.50 14.50 0.55 - Wall 2-3 Seg 1 24.00 29.00 38.00 9.00 9.00 0.89 - Line 3 Level 1 Line 3 Seg 1 32.00 0.00 29.00 29.00 7.00 - 8.00 Wall 3-1 Seg 1 32.00 22.00 29.00 7.00 7.00 1.14 - Line 4 Level 1 Line 4 Seg 1 44.00 0.00 22.00 22.00 22.00 - 8.00 Wall 4-1 Seg 1 44.00 0.00 22.00 22.00 22.00 0.36 - East-west Type Wall Location Extent [ft]Length FHS Aspect Height Shearlines Group Y [ft]Start End [ft] [ft] Ratio [ft] Line A Level 1 Line A 1 0.00 24.00 44.00 20.00 6.00 - 8.00 Wall A-1 Seg 1 0.00 24.00 44.00 20.00 6.00 - - Segment 1 -- 24.00 27.00 3.00 - 2.67 - Opening 1 -- 27.00 41.00 14.00 - - 8.00 Segment 2 -- 41.00 44.00 3.00 - 2.67 - Line B Level 2 Line B 1 8.00 0.00 24.00 24.00 16.00 - 8.00 Wall B-1 Seg 1 8.00 0.00 24.00 24.00 16.00 - - Segment 1 -- 0.00 4.50 4.50 - 1.78 - Opening 1 -- 4.50 9.50 5.00 - - 8.00 Segment 2 -- 9.50 16.00 6.50 - 1.23 - Opening 2 -- 16.00 19.00 3.00 - - 8.00 Segment 3 -- 19.00 24.00 5.00 - 1.60 - Level 1 Line B 1 8.00 0.00 44.00 44.00 12.00 - 8.00 Wall B-1 Seg 1 8.00 0.00 24.00 24.00 12.00 - - Segment 1 -- 0.00 3.00 3.00 - 2.67 - Opening 1 -- 3.00 12.00 9.00 - - 8.00 Segment 2 -- 12.00 17.00 5.00 - 1.60 - Opening 2 -- 17.00 20.00 3.00 - - 8.00 Segment 3 -- 20.00 24.00 4.00 - 2.00 - Line C Level 1 Line C Seg 1 22.00 0.00 44.00 44.00 12.00 - 8.00 Wall C-1 Seg 1 22.00 32.00 44.00 12.00 12.00 0.67 - Line D Level 1 Line D 1 29.00 0.00 32.00 32.00 4.00 - 8.00 Wall D-1 Seg 1 29.00 24.00 32.00 8.00 4.00 - - Segment 1 -- 24.00 26.00 2.00 - 4.00 - Opening 1 -- 26.00 28.00 2.00 - - 8.00 Segment 2 -- 28.00 32.00 4.00 - 2.00 - Line E Level 2 4 Page 13 of 68 WoodWorks® Shearwalls 200691 - Lateral Analysis.wsw Jan. 25, 2021 13:51:04 SHEARLINE, WALL and OPENING DIMENSIONS (continued) Line E 1 38.00 0.00 24.00 24.00 12.00 - 8.00 Wall E-1 Seg 1 38.00 0.00 24.00 24.00 12.00 - - Segment 1 -- 0.00 4.00 4.00 - 2.00 - Opening 1 -- 4.00 8.00 4.00 - - 8.00 Segment 2 -- 8.00 16.00 8.00 - 1.00 - Opening 2 -- 16.00 22.00 6.00 - - 8.00 Segment 3 -- 22.00 24.00 2.00 - 4.00 - Level 1 Line E 1 38.00 0.00 24.00 24.00 12.00 - 8.00 Wall E-1 Seg 1 38.00 0.00 24.00 24.00 12.00 - - Segment 1 -- 0.00 4.00 4.00 - 2.00 - Opening 1 -- 4.00 8.00 4.00 - - 8.00 Segment 2 -- 8.00 16.00 8.00 - 1.00 - Opening 2 -- 16.00 22.00 6.00 - - 8.00 Segment 3 -- 22.00 24.00 2.00 - 4.00 - Legend: Type - Seg = segmented, Prf = perforated, NSW = non-shearwall Location - Dimension perpendicular to wall FHS - Length of full-height sheathing used to resist shear force. For perforated walls, it is based on the factored segments Li defined in SDPWS 4.3.4.3 Aspect Ratio – Ratio of wall height to segment length (h/bs) Wall Group - Wall design group defined in Sheathing and Framing Materials tables, where it shows associated Standard Wall 5 Page 14 of 68 WoodWorks® Shearwalls 200691 - Lateral Analysis.wsw Jan. 25, 2021 13:51:04 Design Summary SHEARWALL DESIGN Wind Shear Loads, Flexible Diaphragm All shearwalls have sufficient design capacity. Components and Cladding Wind Loads, Out-of-plane Sheathing All shearwalls have sufficient design capacity. Components and Cladding Wind Loads, Nail Withdrawal All shearwalls have sufficient design capacity. Seismic Loads, Flexible Diaphragm All shearwalls have sufficient design capacity. HOLDDOWN DESIGN Wind Loads, Flexible Diaphragm All hold-downs have sufficient design capacity. Seismic Loads, Flexible Diaphragm All hold-downs have sufficient design capacity. This Design Summary does not include failures that occur due to excessive story drift from ASCE 7 CC1.2 (wind) or 12.12 (seismic). Refer to Story Drift table in this report to verify this design criterion. Refer to the Deflection table for possible issues regarding fastener slippage (SDPWS Table C4.2.2D). 6 Page 15 of 68 WoodWorks® Shearwalls 200691 - Lateral Analysis.wsw Jan. 25, 2021 13:51:04 Flexible Diaphragm Wind Design ASCE 7 Directional (All Heights) Loads SHEAR RESULTS N-S W For ASD Shear Force [plf]Asp-Cub Allowable Shear [plf]Resp. Shearlines Gp Dir v vmax V [lbs]Int Ext Int Ext Co C Cmb V [lbs]Ratio Line 1 Level 2 Ln1, Lev2 1 Both 41.4 - 1243 - 1.0 - 339 - 339 10156 0.12 Level 1 Ln1, Lev1 - S->N - - 2474 - - - 339 - - 8548 - - N->S - - 2689 - - - 339 - - 8548 - Wall 1-1 1 S->N - - 2474 - 1.0 - 339 - - 8548 - 1 N->S - - 2689 - 1.0 - 339 - - 8548 - Seg. 1 - S->N 98.0 - 2254 - 1.0 - 339 - 339 7786 0.29 - N->S 106.5 - 2450 - 1.0 - 339 - 339 7786 0.31 Seg. 2 - S->N 73.5 - 220 - .75 - 254 - 254 762 0.29 - N->S 79.9 - 240 - .75 - 254 - 254 762 0.31 Line 2 Level 2 Ln2, Lev2 - Both - - 1243 - - - 339 - - 9479 - Wall 2-1 1 Both - - 1243 - 1.0 - 339 - - 9479 - Seg. 1 - Both 44.4 - 710 - 1.0 - 339 - 339 5416 0.13 Seg. 2 - Both 44.4 - 533 - 1.0 - 339 - 339 4062 0.13 Level 1 Ln2, Lev1 - S->N - - 2855 - - - 339 - - 10663 - - N->S - - 3039 - - - 339 - - 10663 - Wall 2-1 1 S->N 90.6 - 725 - 1.0 - 339 - 339 2708 0.27 1 N->S 96.5 - 772 - 1.0 - 339 - 339 2708 0.28 Wall 2-2 1 S->N 90.6 - 1314 - 1.0 - 339 - 339 4909 0.27 1 N->S 96.5 - 1399 - 1.0 - 339 - 339 4909 0.28 Wall 2-3 1 S->N 90.6 - 816 - 1.0 - 339 - 339 3047 0.27 1 N->S 96.5 - 868 - 1.0 - 339 - 339 3047 0.28 Line 3 Ln3, Lev1 - Both - - 1019 - - - 339 - - 2370 - Wall 3-1 1 Both 145.6 - 1019 - 1.0 - 339 - 339 2370 0.43 Line 4 Ln4, Lev1 1 Both 27.6 - 608 - 1.0 - 339 - 339 7447 0.08 E-W W For ASD Shear Force [plf]Asp-Cub Allowable Shear [plf]Resp. Shearlines Gp Dir v vmax V [lbs]Int Ext Int Ext Co C Cmb V [lbs]Ratio Line A Level 1 LnA, Lev1 - W->E - - 254 - - - 339 - - 1523 - - E->W - - 276 - - - 339 - - 1523 - Wall A-1 1 W->E - - 254 - 1.0 - 339 - - 1523 - 1 E->W - - 276 - 1.0 - 339 - - 1523 - Seg. 1 - W->E 42.4 - 127 - .75 - 254 - 254 762 0.17 - E->W 45.9 - 138 - .75 - 254 - 254 762 0.18 Seg. 2 - W->E 42.4 - 127 - .75 - 254 - 254 762 0.17 - E->W 45.9 - 138 - .75 - 254 - 254 762 0.18 Line B Level 2 LnB, Lev2 - Both - - 1277 - - - 339 - - 5416 - Wall B-1 1 Both - - 1277 - 1.0 - 339 - - 5416 - Seg. 1 - Both 79.8 - 359 - 1.0 - 339 - 339 1523 0.24 Seg. 2 - Both 79.8 - 519 - 1.0 - 339 - 339 2200 0.24 Seg. 3 - Both 79.8 - 399 - 1.0 - 339 - 339 1693 0.24 Level 1 LnB, Lev1 - W->E - - 2508 - - - 339 - - 3808 - - E->W - - 2698 - - - 339 - - 3808 - Wall B-1 1 W->E - - 2508 - 1.0 - 339 - - 3808 - 1 E->W - - 2698 - 1.0 - 339 - - 3808 - Seg. 1 - W->E 167.2 - 502 - .75 - 254 - 254 762 0.66 - E->W 179.9 - 540 - .75 - 254 - 254 762 0.71 Seg. 2 - W->E 222.9 - 1115 - 1.0 - 339 - 339 1693 0.66 - E->W 239.8 - 1199 - 1.0 - 339 - 339 1693 0.71 Seg. 3 - W->E 222.9 - 892 - 1.0 - 339 - 339 1354 0.66 - E->W 239.8 - 959 - 1.0 - 339 - 339 1354 0.71 Line C LnC, Lev1 - W->E - - 1226 - - - 339 - - 4062 - - E->W - - 1368 - - - 339 - - 4062 - 7 Page 16 of 68 WoodWorks® Shearwalls 200691 - Lateral Analysis.wsw Jan. 25, 2021 13:51:04 SHEAR RESULTS (flexible wind design, continued) Wall C-1 1 W->E 102.2 - 1226 - 1.0 - 339 - 339 4062 0.30 1 E->W 114.0 - 1368 - 1.0 - 339 - 339 4062 0.34 Line D LnD, Lev1 - W->E - - 769 - - - 339 - - 1354 - - E->W - - 778 - - - 339 - - 1354 - Wall D-1 1 W->E - - 769 - 1.0 - 339 - - 1354 - 1 E->W - - 778 - 1.0 - 339 - - 1354 - Seg. 1 - Both 0.0 - 0 - 1.0 - 339 - 339 - - Seg. 2 - W->E 192.2 - 769 - 1.0 - 339 - 339 1354 0.57 - E->W 194.5 - 778 - 1.0 - 339 - 339 1354 0.57 Line E Level 2 LnE, Lev2 - Both - - 1277 - - - 339 - - 4062 - Wall E-1 1 Both - - 1277 - 1.0 - 339 - - 4062 - Seg. 1 - Both 106.4 - 426 - 1.0 - 339 - 339 1354 0.31 Seg. 2 - Both 106.4 - 851 - 1.0 - 339 - 339 2708 0.31 Seg. 3 - Both 0.0 - 0 - 1.0 - 339 - 339 - - Level 1 LnE, Lev1 - Both - - 1701 - - - 339 - - 4062 - Wall E-1 1 Both - - 1701 - 1.0 - 339 - - 4062 - Seg. 1 - Both 141.7 - 567 - 1.0 - 339 - 339 1354 0.42 Seg. 2 - Both 141.7 - 1134 - 1.0 - 339 - 339 2708 0.42 Seg. 3 - Both 0.0 - 0 - 1.0 - 339 - 339 - - Legend: W Gp - Wall design group defined in Sheathing and Framing Materials tables, where it shows associated Standard Wall. "^" means that this wall is critical for all walls in the Standard Wall group. For Dir - Direction of wind force along shearline. v - Design shear force on segment = ASD factored shear force per unit FHS vmax - Collector shear force for perforated walls as per SDPWS eqn. 4.3-8 = V/FHS/Co. Full height sheathing (FHS) factored for narrow segments as per 4.3.4.3 V - ASD factored shear force. For shearline: total shearline force. For wall: total of all segments on wall. For segment: force on segment Asp/Cub – For wall: Unblocked structural wood panel factor Cub from SDPWS 4.3.3.2. For segment: Aspect ratio adjustment from SDPWS 4.3.3.4.1 Int - Unit shear capacity of interior sheathing; Ext - Unit shear capacity of exterior sheathing. For wall: Unfactored. For segment: Include Cub factor and aspect ratio adjustments. Co - Adjustment factor for perforated walls from SDPWS Equation 4.3-5. C - Sheathing combination rule, A = Add capacities, S = Strongest side or twice weakest, G = Stiffness-based using SDPWS 4.3-3. Cmb - Combined interior and exterior unit shear capacity including perforated wall factor Co. V – Total factored shear capacity of shearline, wall or segment. Crit Resp – Response ratio = v/Cmb = design shear force/unit shear capacity. "S" indicates that the wind design criterior was critical in selecting wall. Notes: Refer to Elevation View diagrams for individual level for uplift anchorage force t for perforated walls given by SDPWS 4.3.6.4.2,4. 8 Page 17 of 68 WoodWorks® Shearwalls 200691 - Lateral Analysis.wsw Jan. 25, 2021 13:51:04 Flexible Diaphragm Seismic Design SEISMIC INFORMATION Level Mass Area Story Shear [lbs]Diaphragm Force Fpx [lbs] [lbs][sq.ft]E-W N-S E-W N-S 2 20853 720.0 3850 3850 3850 3850 1 38617 1216.0 3774 3774 6436 6436 All 59470 - 7624 7624 - - Legend: Building mass – Sum of all generated and input building masses on level = wx in ASCE 7 equation 12.8-12. Storey shear – Total unfactored (strength-level) shear force induced at level x, = Fx in ASCE 7 equation 12.8-11. Diaphragm force Fpx - Unfactored force intended for diaphragm design from Eqn 12.10-1; used by Shearwalls only for drag strut forces, see 12.10.2.1 Exception 2. Redundancy Factor p (rho): E-W 1.00, N-S 1.00 Automatically calculated according to ASCE 7 12.3.4.2. Vertical Earthquake Load Ev Ev = 0.2 Sds D; Sds = 0.83; Ev = 0.167 D unfactored; 0.117 D factored; total dead load factor: 0.6 - 0.117 = 0.483 tension, 1.0 + 0.117 = 1.117 compression. 10 Page 18 of 68 WoodWorks® Shearwalls 200691 - Lateral Analysis.wsw Jan. 25, 2021 13:51:04 SHEAR RESULTS (flexible seismic design) N-S W For ASD Shear Force [plf]Asp-Cub Allowable Shear [plf]Resp. Shearlines Gp Dir v vmax V [lbs]Int Ext Int Ext Co C Cmb V [lbs]Ratio Line 1 Level 2 Ln1, Lev2 1 Both 44.9 - 1347 - 1.0 - 242 - 242 7254 0.19 Level 1 Ln1, Lev1 - Both - - 2007 - - - 242 - - 6105 - Wall 1-1 1 Both - - 2007 - 1.0 - 242 - - 6105 - Seg. 1 - Both 79.5 - 1828 - 1.0 - 242 - 242 5561 0.33 Seg. 2 - Both 59.6 - 179 - .75 - 181 - 181 544 0.33 Line 2 Level 2 Ln2, Lev2 - Both - - 1347 - - - 242 - - 6770 - Wall 2-1 1 Both - - 1347 - 1.0 - 242 - - 6770 - Seg. 1 - Both 48.1 - 770 - 1.0 - 242 - 242 3869 0.20 Seg. 2 - Both 48.1 - 577 - 1.0 - 242 - 242 2902 0.20 Level 1 Ln2, Lev1 - Both - - 2213 - - - 242 - - 7617 - Wall 2-1 1 Both 70.2 - 562 - 1.0 - 242 - 242 1934 0.29 Wall 2-2 1 Both 70.2 - 1019 - 1.0 - 242 - 242 3506 0.29 Wall 2-3 1 Both 70.2 - 632 - 1.0 - 242 - 242 2176 0.29 Line 3 Ln3, Lev1 - Both - - 673 - - - 242 - - 1693 - Wall 3-1 1 Both 96.2 - 673 - 1.0 - 242 - 242 1693 0.40 Line 4 Ln4, Lev1 1 Both 20.2 - 444 - 1.0 - 242 - 242 5320 0.08 E-W W For ASD Shear Force [plf]Asp-Cub Allowable Shear [plf]Resp. Shearlines Gp Dir v vmax V [lbs]Int Ext Int Ext Co C Cmb V [lbs]Ratio Line A Level 1 LnA, Lev1 - Both - - 349 - - - 242 - - 1088 - Wall A-1 1 Both - - 349 - 1.0 - 242 - - 1088 - Seg. 1 - Both 58.1 - 174 - .75 - 181 - 181 544 0.32 Seg. 2 - Both 58.1 - 174 - .75 - 181 - 181 544 0.32 Line B Level 2 LnB, Lev2 - Both - - 1347 - - - 242 - - 3869 - Wall B-1 1 Both - - 1347 - 1.0 - 242 - - 3869 - Seg. 1 - Both 84.2 - 379 - 1.0 - 242 - 242 1088 0.35 Seg. 2 - Both 84.2 - 547 - 1.0 - 242 - 242 1572 0.35 Seg. 3 - Both 84.2 - 421 - 1.0 - 242 - 242 1209 0.35 Level 1 LnB, Lev1 - Both - - 2337 - - - 242 - - 2720 - Wall B-1 1^Both - - 2337 - 1.0 - 242 - - 2720 - Seg. 1 - Both 155.8 - 467 - .75 - 181 - 181 544 0.86 Seg. 2 - Both 207.7 - 1039 - 1.0 - 242 - 242 1209 0.86 Seg. 3 - Both 207.7 - 831 - 1.0 - 242 - 242 967 0.86 Line C LnC, Lev1 - Both - - 726 - - - 242 - - 2902 - Wall C-1 1 Both 60.5 - 726 - 1.0 - 242 - 242 2902 0.25 Line D LnD, Lev1 - Both - - 321 - - - 242 - - 967 - Wall D-1 1 Both - - 321 - 1.0 - 242 - - 967 - Seg. 1 - Both 0.0 - 0 - 1.0 - 242 - 242 - - Seg. 2 - Both 80.3 - 321 - 1.0 - 242 - 242 967 0.33 Line E Level 2 LnE, Lev2 - Both - - 1347 - - - 242 - - 2902 - Wall E-1 1 Both - - 1347 - 1.0 - 242 - - 2902 - Seg. 1 - Both 112.3 - 449 - 1.0 - 242 - 242 967 0.46 Seg. 2 - Both 112.3 - 898 - 1.0 - 242 - 242 1934 0.46 Seg. 3 - Both 0.0 - 0 - 1.0 - 242 - 242 - - Level 1 LnE, Lev1 - Both - - 1604 - - - 242 - - 2902 - Wall E-1 1 Both - - 1604 - 1.0 - 242 - - 2902 - Seg. 1 - Both 133.7 - 535 - 1.0 - 242 - 242 967 0.55 Seg. 2 - Both 133.7 - 1070 - 1.0 - 242 - 242 1934 0.55 Seg. 3 - Both 0.0 - 0 - 1.0 - 242 - 242 - - Legend: W Gp - Wall design group defined in Sheathing and Framing Materials tables, where it shows associated Standard Wall. "^" means that this wall is 11 Page 19 of 68 WoodWorks® Shearwalls 200691 - Lateral Analysis.wsw Jan. 25, 2021 13:51:04 critical for all walls in the Standard Wall group. For Dir – Direction of seismic force along shearline. v - Design shear force on segment = ASD factored shear force per unit FHS vmax - Collector shear force for perforated walls as per SDPWS eqn. 4.3-8 = V/FHS/Co. Full height sheathing (FHS) factored for narrow segments as per 4.3.4.3 V - ASD factored shear force. For shearline: total shearline force. For wall: total of all segments on wall. For segment: force on segment Asp/Cub – For wall: Unblocked structural wood panel factor Cub from SDPWS 4.3.3.2. For segment: Aspect ratio adjustment from SDPWS 4.3.3.4.1 Int - Unit shear capacity of interior sheathing; Ext - Unit shear capacity of exterior sheathing. For wall: Unfactored. For segment: Include Cub factor and aspect ratio adjustments. Co - Adjustment factor for perforated walls from SDPWS Equation 4.3-5. C - Sheathing combination rule, A = Add capacities, S = Strongest side or twice weakest, G = Stiffness-based using SDPWS 4.3-3. Cmb - Combined interior and exterior unit shear capacity including perforated wall factor Co. V – Total factored shear capacity of shearline, wall or segment. Crit Resp – Response ratio = v/Cmb = design shear force/unit shear capacity. "W" indicates that the wind design criterior was critical in selecting wall. Notes: Refer to Elevation View diagrams for individual level for uplift anchorage force t for perforated walls given by SDPWS 4.3.6.4.2,4. 12 Page 20 of 68 ROOF FRAMING Member Name Results Current Solution Comments R1 Passed 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 R2 Passed 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 R3 Passed 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 R4 Passed 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 R5 Passed 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 R6 Passed 1 piece(s) 3 1/2" x 15" 24F-V4 DF Glulam R7 Passed 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 R8 Passed 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 UPPER FLOOR FRAMING Member Name Results Current Solution Comments U1 Passed 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 U2 Passed 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 U3 Passed 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 U4 Passed 1 piece(s) 4 x 10 Douglas Fir-Larch No. 2 U5 Passed 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 U6 Passed 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 U7 Passed 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 U8 Passed 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 U9 Passed 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 U10 Passed 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 U11 Passed 1 piece(s) 11 7/8" TJI® 110 @ 19.2" OC U12 Passed 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 U13 Passed 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 FLOOR FRAMING Member Name Results Current Solution Comments M1 Passed 1 piece(s) 4 x 12 Douglas Fir-Larch No. 2 M2 Passed 1 piece(s) 4 x 12 Douglas Fir-Larch No. 2 M3 Passed 1 piece(s) 11 7/8" TJI® 110 @ 19.2" OC M4 Passed 1 piece(s) 1 3/4" x 11 7/8" 2.0E Microllam® LVL M5 Passed 1 piece(s) 4 x 12 Douglas Fir-Larch No. 2 BEAM CALCULATIONS 200691 JOB SUMMARY REPORT ForteWEB Software Operator Job Notes 1/21/2021 11:08:13 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 Alec@Hodgeengineering.com ForteWEB v3.1 File Name: BEAM CALCULATIONS 200691 Page 1 / 27Page 21 of 68 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)100 @ 0 3281 (1.50")Passed (3%)--1.0 D + 1.0 S (All Spans) Shear (lbs)35 @ 8 3/4"3502 Passed (1%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)56 @ 1' 1 1/2"3438 Passed (2%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.000 @ 1' 1 1/2"0.075 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.000 @ 1' 1 1/2"0.112 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - HF 1.50"1.50"1.50"44 56 100 None 2 - Trimmer - HF 1.50"1.50"1.50"44 56 100 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)2' 3" o/c Bottom Edge (Lu)2' 3" o/c Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 2' 3"N/A 6.4 -- 1 - Uniform (PSF)0 to 2' 3"2'16.2 25.0 ROOF Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED ROOF FRAMING, R1 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 ForteWEB Software Operator Job Notes 1/21/2021 11:08:13 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 Alec@Hodgeengineering.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: BEAM CALCULATIONS 200691 Page 2 / 27Page 22 of 68 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1150 @ 0 3281 (1.50")Passed (35%)--1.0 D + 1.0 S (All Spans) Shear (lbs)634 @ 8 3/4"3502 Passed (18%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)934 @ 1' 7 1/2"3438 Passed (27%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.006 @ 1' 7 1/2"0.108 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.010 @ 1' 7 1/2"0.162 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - HF 1.50"1.50"1.50"459 691 1150 None 2 - Trimmer - HF 1.50"1.50"1.50"459 691 1150 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)3' 3" o/c Bottom Edge (Lu)3' 3" o/c Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 3' 3"N/A 6.4 -- 1 - Uniform (PSF)0 to 3' 3"17'16.2 25.0 ROOF Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED ROOF FRAMING, R2 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 ForteWEB Software Operator Job Notes 1/21/2021 11:08:13 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 Alec@Hodgeengineering.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: BEAM CALCULATIONS 200691 Page 3 / 27Page 23 of 68 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1504 @ 0 3281 (1.50")Passed (46%)--1.0 D + 1.0 S (All Spans) Shear (lbs)988 @ 8 3/4"3502 Passed (28%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)1598 @ 2' 1 1/2"3438 Passed (46%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.018 @ 2' 1 1/2"0.142 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.029 @ 2' 1 1/2"0.213 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - HF 1.50"1.50"1.50"601 903 1504 None 2 - Trimmer - HF 1.50"1.50"1.50"601 903 1504 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)4' 3" o/c Bottom Edge (Lu)4' 3" o/c Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 4' 3"N/A 6.4 -- 1 - Uniform (PSF)0 to 4' 3"17'16.2 25.0 ROOF Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED ROOF FRAMING, R3 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 ForteWEB Software Operator Job Notes 1/21/2021 11:08:13 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 Alec@Hodgeengineering.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: BEAM CALCULATIONS 200691 Page 4 / 27Page 24 of 68 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1858 @ 0 3281 (1.50")Passed (57%)--1.0 D + 1.0 S (All Spans) Shear (lbs)1342 @ 8 3/4"3502 Passed (38%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)2438 @ 2' 7 1/2"3438 Passed (71%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.041 @ 2' 7 1/2"0.175 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.068 @ 2' 7 1/2"0.262 Passed (L/926)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - HF 1.50"1.50"1.50"742 1116 1858 None 2 - Trimmer - HF 1.50"1.50"1.50"742 1116 1858 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)5' 3" o/c Bottom Edge (Lu)5' 3" o/c Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 5' 3"N/A 6.4 -- 1 - Uniform (PSF)0 to 5' 3"17'16.2 25.0 ROOF Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED ROOF FRAMING, R4 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 ForteWEB Software Operator Job Notes 1/21/2021 11:08:13 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 Alec@Hodgeengineering.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: BEAM CALCULATIONS 200691 Page 5 / 27Page 25 of 68 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)773 @ 0 3281 (1.50")Passed (24%)--1.0 D + 1.0 S (All Spans) Shear (lbs)272 @ 8 3/4"3502 Passed (8%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)435 @ 1' 1 1/2"3438 Passed (13%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.001 @ 1' 1 1/2"0.075 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.002 @ 1' 1 1/2"0.112 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - HF 1.50"1.50"1.50"309 464 773 None 2 - Trimmer - HF 1.50"1.50"1.50"309 464 773 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)2' 3" o/c Bottom Edge (Lu)2' 3" o/c Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 2' 3"N/A 6.4 -- 1 - Uniform (PSF)0 to 2' 3"16' 6"16.2 25.0 ROOF Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED ROOF FRAMING, R5 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 ForteWEB Software Operator Job Notes 1/21/2021 11:08:13 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 Alec@Hodgeengineering.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: BEAM CALCULATIONS 200691 Page 6 / 27Page 26 of 68 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)4529 @ 1 1/2"6825 (3.00")Passed (66%)--1.0 D + 1.0 S (All Spans) Shear (lbs)3706 @ 1' 6"10666 Passed (35%)1.15 1.0 D + 1.0 S (All Spans) Pos Moment (Ft-lbs)18122 @ 8' 3"30188 Passed (60%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.288 @ 8' 3"0.542 Passed (L/678)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.486 @ 8' 3"0.813 Passed (L/401)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 16' 3". •The effects of positive or negative camber have not been accounted for when calculating deflection. •The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - HF 3.00"3.00"1.99"1848 2681 4529 None 2 - Trimmer - HF 3.00"3.00"1.99"1848 2681 4529 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)16' 6" o/c Bottom Edge (Lu)16' 6" o/c Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 16' 6"N/A 12.8 -- 1 - Uniform (PSF)0 to 16' 6"13'16.2 25.0 ROOF Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED ROOF FRAMING, R6 1 piece(s) 3 1/2" x 15" 24F-V4 DF Glulam ForteWEB Software Operator Job Notes 1/21/2021 11:08:13 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 Alec@Hodgeengineering.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: BEAM CALCULATIONS 200691 Page 7 / 27Page 27 of 68 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)736 @ 2"4961 (3.50")Passed (15%)--1.0 D + 1.0 S (All Spans) Shear (lbs)582 @ 10 3/4"3502 Passed (17%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)1458 @ 4' 3 1/2"3438 Passed (42%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.059 @ 4' 3 1/2"0.412 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.100 @ 4' 3 1/2"0.550 Passed (L/985)--1.0 D + 1.0 S (All Spans) System : Roof Member Type : Drop Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/240) and TL (L/180). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Stud wall - HF 3.50"3.50"1.50"307 429 736 Blocking 2 - Stud wall - HF 3.50"3.50"1.50"307 429 736 Blocking •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)8' 7" o/c Bottom Edge (Lu)8' 7" o/c Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 8' 7"N/A 6.4 -- 1 - Uniform (PSF)0 to 8' 7" (Front)4'16.2 25.0 ROOF Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED ROOF FRAMING, R7 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 ForteWEB Software Operator Job Notes 1/21/2021 11:08:13 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 Alec@Hodgeengineering.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: BEAM CALCULATIONS 200691 Page 8 / 27Page 28 of 68 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)982 @ 0 3281 (1.50")Passed (30%)--1.0 D + 1.0 S (All Spans) Shear (lbs)542 @ 8 3/4"3502 Passed (15%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)798 @ 1' 7 1/2"3438 Passed (23%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.005 @ 1' 7 1/2"0.108 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.009 @ 1' 7 1/2"0.162 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - HF 1.50"1.50"1.50"393 589 982 None 2 - Trimmer - HF 1.50"1.50"1.50"393 589 982 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)3' 3" o/c Bottom Edge (Lu)3' 3" o/c Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 3' 3"N/A 6.4 -- 1 - Uniform (PSF)0 to 3' 3"14' 6"16.2 25.0 ROOF Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED ROOF FRAMING, R8 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 ForteWEB Software Operator Job Notes 1/21/2021 11:08:13 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 Alec@Hodgeengineering.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: BEAM CALCULATIONS 200691 Page 9 / 27Page 29 of 68 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)417 @ 0 3281 (1.50")Passed (13%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)274 @ 8 3/4"3502 Passed (8%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Moment (Ft-lbs)443 @ 2' 1 1/2"3438 Passed (13%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Live Load Defl. (in)0.003 @ 2' 1 1/2"0.142 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in)0.008 @ 2' 1 1/2"0.213 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - HF 1.50"1.50"1.50"274 85 106 465 None 2 - Trimmer - HF 1.50"1.50"1.50"274 85 106 465 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)4' 3" o/c Bottom Edge (Lu)4' 3" o/c Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 4' 3"N/A 6.4 ---- 1 - Uniform (PSF)0 to 4' 3"2'16.2 -25.0 ROOF 2 - Uniform (PLF)0 to 4' 3"N/A 80.0 --WALL 3 - Uniform (PSF)0 to 4' 3"1'10.0 40.0 -FLOOR Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED UPPER FLOOR FRAMING, U1 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 ForteWEB Software Operator Job Notes 1/21/2021 11:08:13 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 Alec@Hodgeengineering.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: BEAM CALCULATIONS 200691 Page 10 / 27Page 30 of 68 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1445 @ 0 3281 (1.50")Passed (44%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)973 @ 1' 6 1/4"3502 Passed (28%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)1009 @ 1' 3"3438 Passed (29%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.003 @ 1' 1 3/8"0.075 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in)0.005 @ 1' 1 5/16"0.112 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - HF 1.50"1.50"1.50"648 315 747 1710 None 2 - Trimmer - HF 1.50"1.50"1.50"501 315 588 1404 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)2' 3" o/c Bottom Edge (Lu)2' 3" o/c Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 2' 3"N/A 6.4 ---- 1 - Uniform (PSF)0 to 1' 3"17'16.2 -25.0 ROOF 2 - Uniform (PLF)0 to 1' 3"N/A 80.0 --FLOOR 3 - Uniform (PSF)0 to 2' 3"7'10.0 40.0 -FLOOR 4 - Uniform (PSF)0 to 2' 3"2'16.2 -25.0 LOWER ROOF 5 - Point (lb)1' 3"N/A 459 -691 Linked from: R2, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED UPPER FLOOR FRAMING, U2 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 ForteWEB Software Operator Job Notes 1/21/2021 11:08:13 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 Alec@Hodgeengineering.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: BEAM CALCULATIONS 200691 Page 11 / 27Page 31 of 68 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1878 @ 3' 3"3281 (1.50")Passed (57%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)1126 @ 2' 6 1/4"3502 Passed (32%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Moment (Ft-lbs)1626 @ 1' 10"3438 Passed (47%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Live Load Defl. (in)0.009 @ 1' 7 7/8"0.108 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in)0.015 @ 1' 7 15/16"0.162 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - HF 1.50"1.50"1.50"487 455 514 1456 None 2 - Trimmer - HF 1.50"1.50"1.50"831 455 942 2228 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)3' 3" o/c Bottom Edge (Lu)3' 3" o/c Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 3' 3"N/A 6.4 ---- 1 - Uniform (PSF)1' 10" to 3' 3"17'16.2 -25.0 ROOF 2 - Uniform (PLF)1' 10" to 3' 3"N/A 80.0 --FLOOR 3 - Uniform (PSF)0 to 3' 3"7'10.0 40.0 -FLOOR 4 - Uniform (PSF)0 to 3' 3"2'16.2 -25.0 LOWER ROOF 5 - Point (lb)1' 10"N/A 459 -691 Linked from: R2, Support 2 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED UPPER FLOOR FRAMING, U3 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 ForteWEB Software Operator Job Notes 1/21/2021 11:08:13 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 Alec@Hodgeengineering.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: BEAM CALCULATIONS 200691 Page 12 / 27Page 32 of 68 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2738 @ 4' 3"3281 (1.50")Passed (83%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)2003 @ 10 3/4"4468 Passed (45%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)3367 @ 1' 9 1/2"5166 Passed (65%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Live Load Defl. (in)0.015 @ 2' 1 5/8"0.142 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in)0.028 @ 2' 1 11/16"0.213 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - HF 1.50"1.50"1.50"1029 595 1118 2742 None 2 - Trimmer - HF 1.50"1.50"1.50"1311 595 1308 3214 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)4' 3" o/c Bottom Edge (Lu)4' 3" o/c Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 4' 3"N/A 8.2 ---- 1 - Uniform (PSF)1' 8" to 4' 3"17'16.2 -25.0 ROOF 2 - Uniform (PLF)1' 8" to 4' 3"N/A 80.0 --FLOOR 3 - Uniform (PSF)0 to 4' 3"7'10.0 40.0 -FLOOR 4 - Uniform (PSF)0 to 4' 3"2'16.2 -25.0 LOWER ROOF 5 - Uniform (PLF)1' 8" to 4' 3"N/A 80.0 --WALL 6 - Point (lb)1' 8"N/A 742 -1116 Linked from: R4, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED UPPER FLOOR FRAMING, U4 1 piece(s) 4 x 10 Douglas Fir-Larch No. 2 ForteWEB Software Operator Job Notes 1/21/2021 11:08:13 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 Alec@Hodgeengineering.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: BEAM CALCULATIONS 200691 Page 13 / 27Page 33 of 68 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2613 @ 0 3281 (1.50")Passed (80%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)1861 @ 8 3/4"3502 Passed (53%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Moment (Ft-lbs)2759 @ 1' 6"3438 Passed (80%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Live Load Defl. (in)0.025 @ 2' 7/8"0.142 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in)0.044 @ 2' 13/16"0.213 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - HF 1.50"1.50"1.50"1152 595 1353 3100 None 2 - Trimmer - HF 1.50"1.50"1.50"588 595 613 1796 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)4' 3" o/c Bottom Edge (Lu)4' 3" o/c Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 4' 3"N/A 6.4 ---- 1 - Uniform (PSF)0 to 1' 6"17'16.2 -25.0 ROOF 2 - Uniform (PLF)0 to 1' 6"N/A 80.0 --FLOOR 3 - Uniform (PSF)0 to 4' 3"7'10.0 40.0 -FLOOR 4 - Uniform (PSF)0 to 4' 3"2'16.2 -25.0 LOWER ROOF 5 - Uniform (PLF)0 to 1' 6"N/A ---WALL 6 - Point (lb)1' 6"N/A 742 -1116 Linked from: R4, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED UPPER FLOOR FRAMING, U5 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 ForteWEB Software Operator Job Notes 1/21/2021 11:08:13 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 Alec@Hodgeengineering.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: BEAM CALCULATIONS 200691 Page 14 / 27Page 34 of 68 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)943 @ 1 1/2"6563 (3.00")Passed (14%)--1.0 D + 1.0 L (All Spans) Shear (lbs)585 @ 10 1/4"3045 Passed (19%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)946 @ 2' 3"2989 Passed (32%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.014 @ 2' 3"0.142 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.017 @ 2' 3"0.213 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Trimmer - HF 3.00"3.00"1.50"200 743 943 None 2 - Trimmer - HF 3.00"3.00"1.50"200 743 943 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)4' 6" o/c Bottom Edge (Lu)4' 6" o/c Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 4' 6"N/A 6.4 -- 1 - Uniform (PSF)0 to 4' 6"8' 3"10.0 40.0 FLOOR Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED UPPER FLOOR FRAMING, U6 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 ForteWEB Software Operator Job Notes 1/21/2021 11:08:13 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 Alec@Hodgeengineering.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: BEAM CALCULATIONS 200691 Page 15 / 27Page 35 of 68 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1901 @ 6' 4 1/2"3281 (1.50")Passed (58%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)1233 @ 5' 7 3/4"3045 Passed (41%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)2352 @ 3' 3 3/4"2989 Passed (79%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.066 @ 3' 2 15/16"0.208 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.095 @ 3' 3 1/8"0.313 Passed (L/793)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - HF 3.00"3.00"1.50"691 1105 462 2258 None 2 - Trimmer - HF 1.50"1.50"1.50"722 1063 510 2295 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)6' 5" o/c Bottom Edge (Lu)6' 5" o/c Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 6' 4 1/2"N/A 6.4 ---- 1 - Uniform (PSF)0 to 6' 4 1/2"8' 6"10.0 40.0 -FLOOR 2 - Uniform (PSF)0 to 1'15'16.2 -25.0 ROOF 3 - Uniform (PLF)0 to 1'N/A 80.0 --WALL 4 - Uniform (PSF)5' 1" to 6' 4 1/2"15'16.2 -25.0 ROOF 5 - Uniform (PLF)5' 1" to 6' 4 1/2"N/A 80.0 --WALL 6 - Point (lb)1'N/A 44 -56 Linked from: R1, Support 1 7 - Point (lb)5' 1"N/A 44 -56 Linked from: R1, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED UPPER FLOOR FRAMING, U7 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 ForteWEB Software Operator Job Notes 1/21/2021 11:08:13 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 Alec@Hodgeengineering.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: BEAM CALCULATIONS 200691 Page 16 / 27Page 36 of 68 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1086 @ 0 3281 (1.50")Passed (33%)--1.0 D + 1.0 L (All Spans) Shear (lbs)510 @ 8 3/4"3045 Passed (17%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)747 @ 1' 4 1/2"2989 Passed (25%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.005 @ 1' 4 1/2"0.092 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.006 @ 1' 4 1/2"0.138 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Trimmer - HF 1.50"1.50"1.50"224 862 1086 None 2 - Trimmer - HF 1.50"1.50"1.50"224 862 1086 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)2' 9" o/c Bottom Edge (Lu)2' 9" o/c Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 2' 9"N/A 6.4 -- 1 - Uniform (PSF)0 to 2' 9"15' 8"10.0 40.0 FLOOR Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED UPPER FLOOR FRAMING, U8 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 ForteWEB Software Operator Job Notes 1/21/2021 11:08:13 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 Alec@Hodgeengineering.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: BEAM CALCULATIONS 200691 Page 17 / 27Page 37 of 68 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1215 @ 0 3281 (1.50")Passed (37%)--1.0 D + 1.0 L (All Spans) Shear (lbs)743 @ 8 3/4"3045 Passed (24%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)1139 @ 1' 10 1/2"2989 Passed (38%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.013 @ 1' 10 1/2"0.125 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.016 @ 1' 10 1/2"0.188 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Trimmer - HF 1.50"1.50"1.50"253 963 1216 None 2 - Trimmer - HF 1.50"1.50"1.50"253 963 1216 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)3' 9" o/c Bottom Edge (Lu)3' 9" o/c Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 3' 9"N/A 6.4 -- 1 - Uniform (PSF)0 to 3' 9"12' 10"10.0 40.0 FLOOR Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED UPPER FLOOR FRAMING, U9 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 ForteWEB Software Operator Job Notes 1/21/2021 11:08:13 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 Alec@Hodgeengineering.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: BEAM CALCULATIONS 200691 Page 18 / 27Page 38 of 68 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)871 @ 0 3281 (1.50")Passed (27%)--1.0 D + 1.0 S (All Spans) Shear (lbs)409 @ 8 3/4"3502 Passed (12%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)598 @ 1' 4 1/2"3438 Passed (17%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.003 @ 1' 4 1/2"0.092 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.005 @ 1' 4 1/2"0.138 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - HF 1.50"1.50"1.50"332 539 871 None 2 - Trimmer - HF 1.50"1.50"1.50"332 539 871 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)2' 9" o/c Bottom Edge (Lu)2' 9" o/c Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 2' 9"N/A 6.4 -- 1 - Uniform (PSF)0 to 2' 9"15' 8"15.0 25.0 ROOF Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED UPPER FLOOR FRAMING, U10 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 ForteWEB Software Operator Job Notes 1/21/2021 11:08:13 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 Alec@Hodgeengineering.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: BEAM CALCULATIONS 200691 Page 19 / 27Page 39 of 68 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)635 @ 2 1/2"1041 (2.25")Passed (61%)1.00 1.0 D + 1.0 L (All Spans) Shear (lbs)620 @ 3 1/2"1560 Passed (40%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)2454 @ 8' 1/2"3160 Passed (78%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.287 @ 8' 1/2"0.392 Passed (L/654)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.359 @ 8' 1/2"0.783 Passed (L/523)--1.0 D + 1.0 L (All Spans) TJ-Pro™ Rating 39 Any Passed ---- System : Floor Member Type : Joist Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •A structural analysis of the deck has not been performed. •Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser Edge™ Panel (24" Span Rating) that is glued and nailed down. •Additional considerations for the TJ-Pro™ Rating include: None. • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Stud wall - HF 3.50"2.25"1.75"129 515 644 1 1/4" Rim Board 2 - Stud wall - HF 3.50"2.25"1.75"129 515 644 1 1/4" Rim Board •TJI joists are only analyzed using Maximum Allowable bracing solutions. •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)3' 6" o/c Bottom Edge (Lu)15' 11" o/c Dead Floor Live Vertical Load Location (Side)Spacing (0.90)(1.00)Comments 1 - Uniform (PSF)0 to 16' 1"19.2"10.0 40.0 FLOOR Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED UPPER FLOOR FRAMING, U11 1 piece(s) 11 7/8" TJI® 110 @ 19.2" OC ForteWEB Software Operator Job Notes 1/21/2021 11:08:13 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 Alec@Hodgeengineering.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: BEAM CALCULATIONS 200691 Page 20 / 27Page 40 of 68 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)340 @ 0 3281 (1.50")Passed (10%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)170 @ 8 3/4"3502 Passed (5%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Moment (Ft-lbs)248 @ 1' 5 1/2"3438 Passed (7%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Live Load Defl. (in)0.001 @ 1' 5 1/2"0.097 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in)0.002 @ 1' 5 1/2"0.146 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - HF 1.50"1.50"1.50"214 58 109 381 None 2 - Trimmer - HF 1.50"1.50"1.50"214 58 109 381 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)2' 11" o/c Bottom Edge (Lu)2' 11" o/c Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 2' 11"N/A 6.4 ---- 1 - Uniform (PSF)0 to 2' 11"2'16.8 -25.0 ROOF 2 - Uniform (PSF)0 to 2' 11"1'16.8 -25.0 LOWER ROOF 3 - Uniform (PLF)0 to 2' 11"N/A 80.0 --WALL 4 - Uniform (PSF)0 to 2' 11"1'10.0 40.0 -FLOOR Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED UPPER FLOOR FRAMING, U12 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 ForteWEB Software Operator Job Notes 1/21/2021 11:08:13 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 Alec@Hodgeengineering.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: BEAM CALCULATIONS 200691 Page 21 / 27Page 41 of 68 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)318 @ 0 3281 (1.50")Passed (10%)--1.0 D + 1.0 S (All Spans) Shear (lbs)179 @ 8 3/4"3502 Passed (5%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)265 @ 1' 8"3438 Passed (8%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.001 @ 1' 8"0.111 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.003 @ 1' 8"0.167 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - HF 1.50"1.50"1.50"214 104 318 None 2 - Trimmer - HF 1.50"1.50"1.50"214 104 318 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)3' 4" o/c Bottom Edge (Lu)3' 4" o/c Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 3' 4"N/A 6.4 -- 1 - Uniform (PSF)0 to 3' 4"2' 6"16.8 25.0 ROOF 2 - Uniform (PLF)0 to 3' 4"N/A 80.0 -wall Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED UPPER FLOOR FRAMING, U13 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 ForteWEB Software Operator Job Notes 1/21/2021 11:08:13 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 Alec@Hodgeengineering.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: BEAM CALCULATIONS 200691 Page 22 / 27Page 42 of 68 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)4041 @ 2"4961 (3.50")Passed (81%)--1.0 D + 1.0 L (All Spans) Shear (lbs)2087 @ 1' 2 3/4"4725 Passed (44%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)4484 @ 2' 6 1/2"6091 Passed (74%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.021 @ 2' 6 1/2"0.158 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.027 @ 2' 6 1/2"0.237 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Floor Member Type : Drop Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Stud wall - HF 3.50"3.50"2.85"991 3050 4041 Blocking 2 - Stud wall - HF 3.50"3.50"2.85"991 3050 4041 Blocking •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)5' 1" o/c Bottom Edge (Lu)5' 1" o/c Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 5' 1"N/A 10.0 -- 1 - Uniform (PSF)0 to 5' 1" (Front)15'10.0 40.0 FLOOR 2 - Uniform (PLF)0 to 5' 1" (Top)N/A 80.0 -WALL 3 - Uniform (PSF)0 to 5' 1" (Front)15'10.0 40.0 FLOOR Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED FLOOR FRAMING, M1 1 piece(s) 4 x 12 Douglas Fir-Larch No. 2 ForteWEB Software Operator Job Notes 1/21/2021 11:08:13 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 Alec@Hodgeengineering.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: BEAM CALCULATIONS 200691 Page 23 / 27Page 43 of 68 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)3737 @ 2"4961 (3.50")Passed (75%)--1.0 D + 1.0 L (All Spans) Shear (lbs)2167 @ 3' 10 1/4"4725 Passed (46%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)3726 @ 2' 3 9/16"6091 Passed (61%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.016 @ 2' 6 7/16"0.158 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.023 @ 2' 6 7/16"0.237 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Floor Member Type : Drop Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Stud wall - HF 3.50"3.50"2.64"1089 2648 435 4172 Blocking 2 - Stud wall - HF 3.50"3.50"2.59"1102 2565 643 4310 Blocking •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)5' 1" o/c Bottom Edge (Lu)5' 1" o/c Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 5' 1"N/A 10.0 ---- 1 - Uniform (PSF)0 to 5' 1" (Front)15'10.0 40.0 -FLOOR 2 - Uniform (PLF)0 to 2' (Top)N/A 80.0 --WALL 3 - Uniform (PSF)0 to 2' (Top)15'10.0 40.0 -UPPER FLOOR 4 - Point (lb)2' (Top)N/A 332 -539 Linked from: U10, Support 1 5 - Point (lb)4' (Top)N/A 332 -539 Linked from: U10, Support 2 6 - Point (lb)4' 3" (Top)N/A 253 963 -Linked from: U9, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED FLOOR FRAMING, M2 1 piece(s) 4 x 12 Douglas Fir-Larch No. 2 ForteWEB Software Operator Job Notes 1/21/2021 11:08:13 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 Alec@Hodgeengineering.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: BEAM CALCULATIONS 200691 Page 24 / 27Page 44 of 68 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)635 @ 2 1/2"1041 (2.25")Passed (61%)1.00 1.0 D + 1.0 L (All Spans) Shear (lbs)620 @ 3 1/2"1560 Passed (40%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)2454 @ 8' 1/2"3160 Passed (78%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.287 @ 8' 1/2"0.392 Passed (L/654)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.359 @ 8' 1/2"0.783 Passed (L/523)--1.0 D + 1.0 L (All Spans) TJ-Pro™ Rating 39 Any Passed ---- System : Floor Member Type : Joist Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •A structural analysis of the deck has not been performed. •Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser Edge™ Panel (24" Span Rating) that is glued and nailed down. •Additional considerations for the TJ-Pro™ Rating include: None. • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Stud wall - HF 3.50"2.25"1.75"129 515 644 1 1/4" Rim Board 2 - Stud wall - HF 3.50"2.25"1.75"129 515 644 1 1/4" Rim Board •TJI joists are only analyzed using Maximum Allowable bracing solutions. •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)3' 6" o/c Bottom Edge (Lu)15' 11" o/c Dead Floor Live Vertical Load Location (Side)Spacing (0.90)(1.00)Comments 1 - Uniform (PSF)0 to 16' 1"19.2"10.0 40.0 FLOOR Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED FLOOR FRAMING, M3 1 piece(s) 11 7/8" TJI® 110 @ 19.2" OC ForteWEB Software Operator Job Notes 1/21/2021 11:08:13 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 Alec@Hodgeengineering.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: BEAM CALCULATIONS 200691 Page 25 / 27Page 45 of 68 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1244 @ 2"1595 (2.25")Passed (78%)--1.0 D + 1.0 L (All Spans) Shear (lbs)1025 @ 1' 3 3/8"3948 Passed (26%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)4083 @ 6' 9 1/2"8924 Passed (46%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.123 @ 6' 9 1/2"0.331 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.287 @ 6' 9 1/2"0.663 Passed (L/554)--1.0 D + 1.0 L (All Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Stud wall - HF 3.50"2.25"1.76"720 543 1263 1 1/4" Rim Board 2 - Beam - HF 3.50"2.25"1.76"720 543 1263 1 1/4" Rim Board •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)11' 2" o/c Bottom Edge (Lu)13' 5" o/c Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)1 1/4" to 13' 5 3/4"N/A 6.1 -- 1 - Uniform (PSF)0 to 13' 7" (Front)2'10.0 40.0 FLOOR 2 - Uniform (PLF)0 to 13' 7" (Front)N/A 80.0 -WALL Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED FLOOR FRAMING, M4 1 piece(s) 1 3/4" x 11 7/8" 2.0E Microllam® LVL ForteWEB Software Operator Job Notes 1/21/2021 11:08:13 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 Alec@Hodgeengineering.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: BEAM CALCULATIONS 200691 Page 26 / 27Page 46 of 68 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)3400 @ 4' 10 1/2"4253 (3.00")Passed (80%)--1.0 D + 1.0 L (All Spans) Shear (lbs)2498 @ 3' 9 3/4"4725 Passed (53%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)4862 @ 3'6091 Passed (80%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.019 @ 2' 6 3/16"0.158 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.027 @ 2' 6 1/4"0.237 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Floor Member Type : Drop Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Stud wall - HF 3.00"3.00"2.03"784 2094 2878 Blocking 2 - Stud wall - HF 3.00"3.00"2.40"989 2412 3401 Blocking •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)5' o/c Bottom Edge (Lu)5' o/c Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 5'N/A 10.0 -- 1 - Uniform (PSF)0 to 5' (Front)15'10.0 40.0 FLOOR 2 - Point (lb)3' (Top)N/A 253 963 Linked from: U9, Support 2 3 - Point (lb)3' (Front)N/A 720 543 Linked from: M4, Support 2 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED FLOOR FRAMING, M5 1 piece(s) 4 x 12 Douglas Fir-Larch No. 2 ForteWEB Software Operator Job Notes 1/21/2021 11:08:13 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 Alec@Hodgeengineering.com ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0 File Name: BEAM CALCULATIONS 200691 Page 27 / 27Page 47 of 68 Page 48 of 68 General Footing Residential Footing File = C:\Users\JOHNHO~1\DOCUME~1\ENERCA~1\2015FO~1.EC6 ENERCALC, INC. 1983-2017, Build:6.17.3.17, Ver:6.17.4.30 Licensee : HODGE ENGINEERING INCLic. # : KW-06007122 Description :24" footing - 1500 psf soil Hodge Engineering Inc. 2615 Jahn Ave NW Ste. E5 Gig Harbor, WA 98332 253-857-7055 John@HodgeEngineering.com Project Title: Engineer:Project ID: Project Descr: Code References Calculations per ACI 318-14, IBC 2015, CBC 2016, ASCE 7-10 Load Combinations Used : IBC 2015 General Information Material Properties Soil Design Values 1.50 Analysis Settings 250.0ksi No ksfAllowable Soil Bearing = = 2.50 60.0 3,122.0 145.0 =0.30 Flexure =0.90 Shear = Valuesj 0.00180 Soil Passive Resistance (for Sliding) 1.0 1.0 = Increases based on footing plan dimension Add Pedestal Wt for Soil Pressure No: Use Pedestal wt for stability, mom & shear No: Allowable pressure increase per foot of depth =ksfwhen max. length or width is greater than =ft : = Add Ftg Wt for Soil Pressure Yes Yes:Use ftg wt for stability, moments & shears when footing base is below ft pcf Increase Bearing By Footing Weight =pcf Min. Overturning Safety Factor = : 1 Increases based on footing Depth0.750 = Soil/Concrete Friction Coeff. Ec : Concrete Elastic Modulus Min. Sliding Safety Factor = = : 1 Footing base depth below soil surface ft =Allow press. increase per foot of depth ksf = = = Concrete Density = Min Allow % Temp Reinf. ksif'c : Concrete 28 day strength fy : Rebar Yield ksi Min Steel % Bending Reinf.Edge Dist. = 3"2'-0"2'-0"Z Z X X 2 - # 4 Bars 3"X-X Section Looking to +Z 2 - # 4 Bars 3"Z-Z Section Looking to +X # Dimensions Width parallel to X-X Axis 2.0 ft Length parallel to Z-Z Axis = 2.0 ft =Pedestal dimensions... px : parallel to X-X Axis in pz : parallel to Z-Z Axis in Height == in Footing Thickness = 8.0 in= Rebar Centerline to Edge of Concrete...=inat Bottom of footing 3.0 Reinforcing # Bars parallel to X-X Axis Reinforcing Bar Size = 4Number of Bars = 2.0 Bars parallel to Z-Z Axis Reinforcing Bar Size =4Number of Bars =2.0 Bandwidth Distribution Check (ACI 15.4.4.2) Direction Requiring Closer Separation n/a # Bars required within zone n/a # Bars required on each side of zone n/a Applied Loads 2.50 3.0 D Lr ksf L S P : Column Load OB : Overburden = k W E M-zz V-x = =k V-z k M-xx = k-ft= k-ft H = Page 49 of 68 General Footing Residential Footing File = C:\Users\JOHNHO~1\DOCUME~1\ENERCA~1\2015FO~1.EC6 ENERCALC, INC. 1983-2017, Build:6.17.3.17, Ver:6.17.4.30 Licensee : HODGE ENGINEERING INCLic. # : KW-06007122 Description :24" footing - 1500 psf soil Hodge Engineering Inc. 2615 Jahn Ave NW Ste. E5 Gig Harbor, WA 98332 253-857-7055 John@HodgeEngineering.com Project Title: Engineer:Project ID: Project Descr: PASS n/a Sliding - X-X 0.0k 0.0k No Sliding PASS n/a Sliding - Z-Z 0.0k 0.0k No Sliding DESIGN SUMMARY Design OK Governing Load CombinationMin. Ratio Item Applied Capacity PASS 0.9813 Soil Bearing 1.472ksf 1.50ksf 0.0 deg CCW PASS n/a Overturning - X-X 0.0k-ft 0.0k-ft No Overturning PASS n/a Overturning - Z-Z 0.0k-ft 0.0k-ft No Overturning PASS n/a Uplift 0.0k 0.0k No Uplift PASS 0.2570 Z Flexure (+X)1.102k-ft 4.288k-ft +1.20D+0.50L+1.60S+1.60H PASS 0.2570 Z Flexure (-X)1.102k-ft 4.288k-ft +1.20D+0.50L+1.60S+1.60H PASS 0.2570 X Flexure (+Z)1.102k-ft 4.288k-ft +1.20D+0.50L+1.60S+1.60H PASS 0.2570 X Flexure (-Z)1.102k-ft 4.288k-ft +1.20D+0.50L+1.60S+1.60H PASS 0.2938 1-way Shear (+X)22.037psi 75.0psi +1.20D+0.50L+1.60S+1.60H PASS 0.2775 1-way Shear (-X)20.813psi 75.0psi +1.20D+0.50L+1.60S+1.60H PASS 0.2938 1-way Shear (+Z)22.037psi 75.0psi +1.20D+0.50L+1.60S+1.60H PASS 0.2775 1-way Shear (-Z)20.813psi 75.0psi +1.20D+0.50L+1.60S+1.60H PASS 0.5289 2-way Punching 79.334psi 150.0psi +1.20D+0.50L+1.60S+1.60H Detailed Results Rotation Axis & ZeccXecc Actual Soil Bearing Stress @ Location Actual / Allow Soil Bearing (in)Gross Allowable Bottom Left Top Left Top Right Bottom Right RatioLoad Combination... , +D+H 0.000 , 0.0 deg CCW 1.50 0.72170.7217 0.7217 0.7217 0.4810.00.0 , +D+L+H 0.000 , 0.0 deg CCW 1.50 0.72170.7217 0.7217 0.7217 0.4810.00.0 , +D+Lr+H 0.000 , 0.0 deg CCW 1.50 0.72170.7217 0.7217 0.7217 0.4810.00.0 , +D+S+H 0.000 , 0.0 deg CCW 1.50 1.4721.472 1.472 1.472 0.9810.00.0 , +D+0.750Lr+0.750L+H 0.000 , 0.0 deg CCW 1.50 0.72170.7217 0.7217 0.7217 0.4810.00.0 , +D+0.750L+0.750S+H 0.000 , 0.0 deg CCW 1.50 1.2841.284 1.284 1.284 0.8560.00.0 , +D+0.60W+H 0.000 , 0.0 deg CCW 1.50 0.72170.7217 0.7217 0.7217 0.4810.00.0 , +D+0.70E+H 0.000 , 0.0 deg CCW 1.50 0.72170.7217 0.7217 0.7217 0.4810.00.0 , +D+0.750Lr+0.750L+0.450W+H 0.000 , 0.0 deg CCW 1.50 0.72170.7217 0.7217 0.7217 0.4810.00.0 , +D+0.750L+0.750S+0.450W+H 0.000 , 0.0 deg CCW 1.50 1.2841.284 1.284 1.284 0.8560.00.0 , +D+0.750L+0.750S+0.5250E+H 0.000 , 0.0 deg CCW 1.50 1.2841.284 1.284 1.284 0.8560.00.0 , +0.60D+0.60W+0.60H 0.000 , 0.0 deg CCW 1.50 0.43300.4330 0.4330 0.4330 0.2890.00.0 , +0.60D+0.70E+0.60H 0.000 , 0.0 deg CCW 1.50 0.43300.4330 0.4330 0.4330 0.2890.00.0 Rotation Axis & Overturning Stability Load Combination...StatusOverturning Moment Resisting Moment Stability Ratio Footing Has NO Overturning Force Application Axis Sliding Stability All units k Load Combination...StatusSliding Force Resisting Force Stability Ratio Footing Has NO Sliding Page 50 of 68 General Footing Residential Footing File = C:\Users\JOHNHO~1\DOCUME~1\ENERCA~1\2015FO~1.EC6 ENERCALC, INC. 1983-2017, Build:6.17.3.17, Ver:6.17.4.30 Licensee : HODGE ENGINEERING INCLic. # : KW-06007122 Description :30" footing - 1500 psf soil Hodge Engineering Inc. 2615 Jahn Ave NW Ste. E5 Gig Harbor, WA 98332 253-857-7055 John@HodgeEngineering.com Project Title: Engineer:Project ID: Project Descr: Code References Calculations per ACI 318-14, IBC 2015, CBC 2016, ASCE 7-10 Load Combinations Used : IBC 2015 General Information Material Properties Soil Design Values 1.50 Analysis Settings 250.0ksi No ksfAllowable Soil Bearing = = 2.50 60.0 3,122.0 145.0 =0.30 Flexure =0.90 Shear = Valuesj 0.00180 Soil Passive Resistance (for Sliding) 1.0 1.0 = Increases based on footing plan dimension Add Pedestal Wt for Soil Pressure No: Use Pedestal wt for stability, mom & shear No: Allowable pressure increase per foot of depth =ksfwhen max. length or width is greater than =ft : = Add Ftg Wt for Soil Pressure Yes Yes:Use ftg wt for stability, moments & shears when footing base is below ft pcf Increase Bearing By Footing Weight =pcf Min. Overturning Safety Factor = : 1 Increases based on footing Depth0.750 = Soil/Concrete Friction Coeff. Ec : Concrete Elastic Modulus Min. Sliding Safety Factor = = : 1 Footing base depth below soil surface ft =Allow press. increase per foot of depth ksf = = = Concrete Density = Min Allow % Temp Reinf. ksif'c : Concrete 28 day strength fy : Rebar Yield ksi Min Steel % Bending Reinf.Edge Dist. = 3"2'-6"2'-6"Z Z X X 3 - # 4 Bars 3"X-X Section Looking to +Z 3 - # 4 Bars 3"Z-Z Section Looking to +X # Dimensions Width parallel to X-X Axis 2.50 ft Length parallel to Z-Z Axis = 2.50 ft =Pedestal dimensions... px : parallel to X-X Axis in pz : parallel to Z-Z Axis in Height == in Footing Thickness = 8.0 in= Rebar Centerline to Edge of Concrete...=inat Bottom of footing 3.0 Reinforcing # Bars parallel to X-X Axis Reinforcing Bar Size = 4Number of Bars = 3.0 Bars parallel to Z-Z Axis Reinforcing Bar Size =4Number of Bars =3.0 Bandwidth Distribution Check (ACI 15.4.4.2) Direction Requiring Closer Separation n/a # Bars required within zone n/a # Bars required on each side of zone n/a Applied Loads 3.0 5.50 D Lr ksf L S P : Column Load OB : Overburden = k W E M-zz V-x = =k V-z k M-xx = k-ft= k-ft H = Page 51 of 68 General Footing Residential Footing File = C:\Users\JOHNHO~1\DOCUME~1\ENERCA~1\2015FO~1.EC6 ENERCALC, INC. 1983-2017, Build:6.17.3.17, Ver:6.17.4.30 Licensee : HODGE ENGINEERING INCLic. # : KW-06007122 Description :30" footing - 1500 psf soil Hodge Engineering Inc. 2615 Jahn Ave NW Ste. E5 Gig Harbor, WA 98332 253-857-7055 John@HodgeEngineering.com Project Title: Engineer:Project ID: Project Descr: PASS n/a Sliding - X-X 0.0k 0.0k No Sliding PASS n/a Sliding - Z-Z 0.0k 0.0k No Sliding DESIGN SUMMARY Design OK Governing Load CombinationMin. Ratio Item Applied Capacity PASS 0.9713 Soil Bearing 1.457ksf 1.50ksf 0.0 deg CCW PASS n/a Overturning - X-X 0.0k-ft 0.0k-ft No Overturning PASS n/a Overturning - Z-Z 0.0k-ft 0.0k-ft No Overturning PASS n/a Uplift 0.0k 0.0k No Uplift PASS 0.3435 Z Flexure (+X)1.750k-ft 5.095k-ft +1.20D+0.50L+1.60S+1.60H PASS 0.3435 Z Flexure (-X)1.750k-ft 5.095k-ft +1.20D+0.50L+1.60S+1.60H PASS 0.3435 X Flexure (+Z)1.750k-ft 5.095k-ft +1.20D+0.50L+1.60S+1.60H PASS 0.3435 X Flexure (-Z)1.750k-ft 5.095k-ft +1.20D+0.50L+1.60S+1.60H PASS 0.4148 1-way Shear (+X)31.111psi 75.0psi +1.20D+0.50L+1.60S+1.60H PASS 0.4148 1-way Shear (-X)31.111psi 75.0psi +1.20D+0.50L+1.60S+1.60H PASS 0.4148 1-way Shear (+Z)31.111psi 75.0psi +1.20D+0.50L+1.60S+1.60H PASS 0.4148 1-way Shear (-Z)31.111psi 75.0psi +1.20D+0.50L+1.60S+1.60H PASS 0.8507 2-way Punching 127.604psi 150.0psi +1.20D+0.50L+1.60S+1.60H Detailed Results Rotation Axis & ZeccXecc Actual Soil Bearing Stress @ Location Actual / Allow Soil Bearing (in)Gross Allowable Bottom Left Top Left Top Right Bottom Right RatioLoad Combination... , +D+H 0.000 , 0.0 deg CCW 1.50 0.57670.5767 0.5767 0.5767 0.3850.00.0 , +D+L+H 0.000 , 0.0 deg CCW 1.50 0.57670.5767 0.5767 0.5767 0.3850.00.0 , +D+Lr+H 0.000 , 0.0 deg CCW 1.50 0.57670.5767 0.5767 0.5767 0.3850.00.0 , +D+S+H 0.000 , 0.0 deg CCW 1.50 1.4571.457 1.457 1.457 0.9710.00.0 , +D+0.750Lr+0.750L+H 0.000 , 0.0 deg CCW 1.50 0.57670.5767 0.5767 0.5767 0.3850.00.0 , +D+0.750L+0.750S+H 0.000 , 0.0 deg CCW 1.50 1.2371.237 1.237 1.237 0.8250.00.0 , +D+0.60W+H 0.000 , 0.0 deg CCW 1.50 0.57670.5767 0.5767 0.5767 0.3850.00.0 , +D+0.70E+H 0.000 , 0.0 deg CCW 1.50 0.57670.5767 0.5767 0.5767 0.3850.00.0 , +D+0.750Lr+0.750L+0.450W+H 0.000 , 0.0 deg CCW 1.50 0.57670.5767 0.5767 0.5767 0.3850.00.0 , +D+0.750L+0.750S+0.450W+H 0.000 , 0.0 deg CCW 1.50 1.2371.237 1.237 1.237 0.8250.00.0 , +D+0.750L+0.750S+0.5250E+H 0.000 , 0.0 deg CCW 1.50 1.2371.237 1.237 1.237 0.8250.00.0 , +0.60D+0.60W+0.60H 0.000 , 0.0 deg CCW 1.50 0.34600.3460 0.3460 0.3460 0.2310.00.0 , +0.60D+0.70E+0.60H 0.000 , 0.0 deg CCW 1.50 0.34600.3460 0.3460 0.3460 0.2310.00.0 Rotation Axis & Overturning Stability Load Combination...StatusOverturning Moment Resisting Moment Stability Ratio Footing Has NO Overturning Force Application Axis Sliding Stability All units k Load Combination...StatusSliding Force Resisting Force Stability Ratio Footing Has NO Sliding Page 52 of 68 Concrete Beam HODGE ENGINEERING INCLic. # : KW-06007122 DESCRIPTION:12" footing with 6" stem wall 1500 psf soil, 2500 psi concrete Hodge Engineering, Inc 3733 Rosedale Street Gig Harbor, WA. 98332 Software copyright ENERCALC, INC. 1983-2019, Build:10.19.1.30 . File = C:\Users\JOHNHO~1\DOCUME~1\ENERCA~1\2015 footing pad calcs.ec6 . CODE REFERENCES Calculations per ACI 318-14, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set : IBC 2015 Material Properties 2.50 7.50 145.0 Elastic Modulus 3,122.0 ksi 1 60.0 29,000.0 40.0 29,000.0 3= =0.90 0.750 f'c ksi fy - Main Rebar ksi Density 1/2 = fr = f'c *375.0 pcf E - Main Rebar ksi psi =1.0OLtWt Factor Fy - Stirrups ksi == = E - Stirrups ksi E 0.850 == = Shear : Stirrup Bar Size # Number of Resisting Legs Per Stirrup Phi Values Flexure : \ I .Cross Section & Reinforcing Details Inverted Tee Section, Stem Width = 6.0 in, Total Height = 18.0 in, Top Flange Width = 12.0 in, Flange Thickness = 6.0 in Span #1 Reinforcing.... 2-#4 at 3.0 in from Bottom, from 0.0 to 5.0 ft in this span 1-#4 at 3.0 in from Top, from 0.0 to 5.0 ft in this span . Beam self weight calculated and added to loads Load for Span Number 1 Uniform Load : D = 0.0150, S = 0.030 ksf, Tributary Width = 15.0 ft, (Roof) Uniform Load : D = 0.010, L = 0.040 ksf, Tributary Width = 7.0 ft, (Floor) Point Load : D = 3.0, S = 7.0 k @ 2.50 ft .Design OKDESIGN SUMMARY Maximum Bending Stress Ratio =0.892 : 1 Span # where maximum occurs Span # 1 Location of maximum on span 2.505 ft Mn * Phi : Allowable 25.551 k-ft Typical SectionSection used for this span Mu : Applied 22.804 k-ft Maximum Deflection 0 <360.0 9596 Ratio =0 <180.0 Max Downward Transient Deflection 0.003 in 19795Ratio =>=360.0 Max Upward Transient Deflection 0.000 in Ratio = Max Downward Total Deflection 0.006 in Ratio =>=180.0 Max Upward Total Deflection 0.000 in . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Overall MAXimum 7.225 7.225 Overall MINimum 0.700 0.700 +D+H 2.600 2.600 +D+L+H 3.300 3.300 +D+Lr+H 2.600 2.600 +D+S+H 7.225 7.225 +D+0.750Lr+0.750L+H 3.125 3.125 +D+0.750L+0.750S+H 6.594 6.594 +D+0.60W+H 2.600 2.600 +D+0.70E+H 2.600 2.600 Page 53 of 68 Concrete Beam HODGE ENGINEERING INCLic. # : KW-06007122 DESCRIPTION:12" footing with 6" stem wall 1500 psf soil, 2500 psi concrete Hodge Engineering, Inc 3733 Rosedale Street Gig Harbor, WA. 98332 Software copyright ENERCALC, INC. 1983-2019, Build:10.19.1.30 . File = C:\Users\JOHNHO~1\DOCUME~1\ENERCA~1\2015 footing pad calcs.ec6 . Span # Bending Stress Results ( k-ft )Location (ft)Load Combination Mu : Max Stress RatioSegmentPhi*Mnxalong Beam MAXimum BENDING Envelope Span # 1 1 5.000 22.80 25.55 0.89 +1.40D+1.60H Span # 1 1 5.000 7.17 25.55 0.28 +1.20D+0.50Lr+1.60L+1.60H Span # 1 1 5.000 7.54 25.55 0.30 +1.20D+1.60L+0.50S+1.60H Span # 1 1 5.000 12.61 25.55 0.49 +1.20D+1.60Lr+0.50L+1.60H Span # 1 1 5.000 6.58 25.55 0.26 +1.20D+1.60Lr+0.50W+1.60H Span # 1 1 5.000 6.14 25.55 0.24 +1.20D+0.50L+1.60S+1.60H Span # 1 1 5.000 22.80 25.55 0.89 +1.20D+1.60S+0.50W+1.60H Span # 1 1 5.000 22.37 25.55 0.88 +1.20D+0.50Lr+0.50L+W+1.60H Span # 1 1 5.000 6.58 25.55 0.26 +1.20D+0.50L+0.50S+W+1.60H Span # 1 1 5.000 11.65 25.55 0.46 +1.20D+0.50L+0.70S+E+1.60H Span # 1 1 5.000 13.68 25.55 0.54 +0.90D+W+0.90H Span # 1 1 5.000 4.61 25.55 0.18 +0.90D+E+0.90H Span # 1 1 5.000 4.61 25.55 0.18 . Location in Span (ft)Load CombinationMax. "-" Defl (in)Location in Span (ft)Load Combination Span Max. "+" Defl (in) Overall Maximum Deflections +D+S+H 1 0.0063 2.500 0.0000 0.000 Page 54 of 68 Concrete Beam HODGE ENGINEERING INCLic. # : KW-06007122 DESCRIPTION:15" footing with 6" stem wall 1500 psf soil, 2500 psi concrete Hodge Engineering, Inc 3733 Rosedale Street Gig Harbor, WA. 98332 Software copyright ENERCALC, INC. 1983-2019, Build:10.19.1.30 . File = C:\Users\JOHNHO~1\DOCUME~1\ENERCA~1\2015 footing pad calcs.ec6 . CODE REFERENCES Calculations per ACI 318-14, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set : IBC 2015 Material Properties 2.50 7.50 145.0 Elastic Modulus 3,122.0 ksi 1 60.0 29,000.0 40.0 29,000.0 3= =0.90 0.750 f'c ksi fy - Main Rebar ksi Density 1/2 = fr = f'c *375.0 pcf E - Main Rebar ksi psi =1.0OLtWt Factor Fy - Stirrups ksi == = E - Stirrups ksi E 0.850 == = Shear : Stirrup Bar Size # Number of Resisting Legs Per Stirrup Phi Values Flexure : \ I .Cross Section & Reinforcing Details Inverted Tee Section, Stem Width = 8.0 in, Total Height = 18.0 in, Top Flange Width = 15.0 in, Flange Thickness = 6.0 in Span #1 Reinforcing.... 2-#4 at 3.0 in from Bottom, from 0.0 to 5.0 ft in this span 1-#4 at 3.0 in from Top, from 0.0 to 5.0 ft in this span . Beam self weight calculated and added to loads Load for Span Number 1 Uniform Load : D = 0.0150, S = 0.030 ksf, Tributary Width = 15.0 ft, (Roof) Uniform Load : D = 0.010, L = 0.040 ksf, Tributary Width = 7.0 ft, (Floor) Point Load : D = 3.0, S = 7.0 k @ 2.50 ft, (Point Load) .Design OKDESIGN SUMMARY Maximum Bending Stress Ratio =0.868 : 1 Span # where maximum occurs Span # 1 Location of maximum on span 2.495 ft Mn * Phi : Allowable 26.452 k-ft Typical SectionSection used for this span Mu : Applied 22.962 k-ft Maximum Deflection 0 <360.0 16719 Ratio =0 <180.0 Max Downward Transient Deflection 0.002 in 25683Ratio =>=360.0 Max Upward Transient Deflection 0.000 in Ratio = Max Downward Total Deflection 0.004 in Ratio =>=180.0 Max Upward Total Deflection 0.000 in . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Overall MAXimum 7.331 7.331 Overall MINimum 0.700 0.700 +D+H 2.706 2.706 +D+L+H 3.406 3.406 +D+Lr+H 2.706 2.706 +D+S+H 7.331 7.331 +D+0.750Lr+0.750L+H 3.231 3.231 +D+0.750L+0.750S+H 6.699 6.699 +D+0.60W+H 2.706 2.706 +D+0.70E+H 2.706 2.706 Page 55 of 68 Concrete Beam HODGE ENGINEERING INCLic. # : KW-06007122 DESCRIPTION:15" footing with 6" stem wall 1500 psf soil, 2500 psi concrete Hodge Engineering, Inc 3733 Rosedale Street Gig Harbor, WA. 98332 Software copyright ENERCALC, INC. 1983-2019, Build:10.19.1.30 . File = C:\Users\JOHNHO~1\DOCUME~1\ENERCA~1\2015 footing pad calcs.ec6 . Span # Bending Stress Results ( k-ft )Location (ft)Load Combination Mu : Max Stress RatioSegmentPhi*Mnxalong Beam MAXimum BENDING Envelope Span # 1 1 5.000 22.96 26.45 0.87 +1.40D+1.60H Span # 1 1 5.000 7.35 26.45 0.28 +1.20D+0.50Lr+1.60L+1.60H Span # 1 1 5.000 7.70 26.45 0.29 +1.20D+1.60L+0.50S+1.60H Span # 1 1 5.000 12.77 26.45 0.48 +1.20D+1.60Lr+0.50L+1.60H Span # 1 1 5.000 6.74 26.45 0.25 +1.20D+1.60Lr+0.50W+1.60H Span # 1 1 5.000 6.30 26.45 0.24 +1.20D+0.50L+1.60S+1.60H Span # 1 1 5.000 22.96 26.45 0.87 +1.20D+1.60S+0.50W+1.60H Span # 1 1 5.000 22.52 26.45 0.85 +1.20D+0.50Lr+0.50L+W+1.60H Span # 1 1 5.000 6.74 26.45 0.25 +1.20D+0.50L+0.50S+W+1.60H Span # 1 1 5.000 11.81 26.45 0.45 +1.20D+0.50L+0.70S+E+1.60H Span # 1 1 5.000 13.84 26.45 0.52 +0.90D+W+0.90H Span # 1 1 5.000 4.73 26.45 0.18 +0.90D+E+0.90H Span # 1 1 5.000 4.73 26.45 0.18 . Location in Span (ft)Load CombinationMax. "-" Defl (in)Location in Span (ft)Load Combination Span Max. "+" Defl (in) Overall Maximum Deflections +D+S+H 1 0.0036 2.500 0.0000 0.000 Page 56 of 68 Hodge Engineering, Inc. 2615 Jahn Ave NW Gig Harbor, WA STe. E5 253-857-7055 Title :4' Unrestrained 40 psf Surcharge Job # :Dsgnr:JEH Page : 1 Description.... 4' Unrestrained wall with 40 psf surcharge This Wall in File: c:\users\johnhodge\documents\retainpro 10 project files\unrestrained walls 2.rpx RetainPro (c) 1987-2016, Build 11.16.06.24 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13License : KW-06053958LicenseTo:HODGE ENGINEERING 4.00 0.50 0.00 12.00 1,500.0 35.0 0.0 250.0 Criteria Soil Data Retained Height =ft Wall height above soil =ft Active Heel Pressure =psf/ftSlope Behind Wall Height of Soil over Toe in Water height over heel =ft = = 110.00= pcf = Soil Density, Heel = Passive Pressure = psf/ft Allow Soil Bearing = psf Soil Density, Toe 110.00pcf Footing||Soil Friction =0.350 Soil height to ignore for passive pressure = 0.00in Equivalent Fluid Pressure Method Surcharge Loads Adjacent Footing Load Load Type 40.0 Lateral Load = 0.0#/ft 0.0 0.0 0.0 0.0 Axial Load Applied to Stem Wall to Ftg CL Dist =0.00ft Wind on Exposed Stem psf0.0= Lateral Load Applied to Stem Surcharge Over Heel =psf Adjacent Footing Load =0.0lbs Axial Dead Load (Service Level) =lbs Footing Type Line Load Surcharge Over Toe psf Footing Width =0.00ft...Height to Top =0.00ft Eccentricity =0.00in...Height to Bottom = 0.00ft Used To Resist Sliding & Overturning Used for Sliding & Overturning = 0.0ft Axial Live Load = Base Above/Below Soil lbs = Axial Load Eccentricity ==Poisson's Ratio 0.300 at Back of Wall in (Service Level) Wind (W)= Design Summary Wall Stability Ratios Overturning =1.67OK Sliding =1.62OK Total Bearing Load =628lbs ...resultant ecc. =3.88in Soil Pressure @ Toe =900psf OK Soil Pressure @ Heel =0psf OK Allowable =1,500 psf Soil Pressure Less Than Allowable ACI Factored @ Toe =2,100psf ACI Factored @ Heel =0psf Footing Shear @ Toe =8.7psi OK Footing Shear @ Heel =7.2psi OK Allowable =75.0psi Sliding Calcs Lateral Sliding Force =440.5lbs less 100% Passive Force less 100% Friction Force Added Force Req'd ....for 1.5 Stability = 0.0= 366.6 347.2 = = 0.0 - lbs lbs lbs OK lbs OK - Masonry Block Type =Medium Weight Stem Construction 3rd 2nd Bar Lap/EmbStem OK Stem OK Bottom Design Height Above Ftg =3.50ft 1.00 0.00 Wall Material Above "Ht" =Concrete Concrete Concrete Thickness =8.00 8.00 8.00 Rebar Size =###4 4 4 Rebar Spacing = 12.00 12.00 12.00 Rebar Placed at =Center Center Center Design Data fb/FB + fa/Fa =0.001 0.101 0.183 Total Force @ Section =l bs Moment....Actual =ft-# Moment.....Allowable =3,387.6 3,387.6 3,387.6ft-# Shear.....Actual =p si Shear.....Allowable =75.0 75.0psi 75.0 Wall Weight = 100.0 100.0psf 100.0 Rebar Depth 'd'= 4.00in 4.00 4.00 Masonry Data f'm =psi Fs =psi Solid Grouting = Modular Ratio 'n'= Short Term Factor = Equiv. Solid Thick.= Concrete Data f'c =2,500.0 2,500.0psi 2,500.0 Fy =60,000.0 60,000.0 Masonry Design Method ASD= Load Factors Building Code IBC 2015,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 psi 60,000.0 Service Level = 17.2 313.1lbs 423.7Strength Level Service Level Strength Level = 3.7 343.6 619.2ft-# Service Level Strength Level = 0.4 6.5 8.8psi Design Method = LRFD LRFD LRFD Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing Page 57 of 68 Hodge Engineering, Inc. 2615 Jahn Ave NW Gig Harbor, WA STe. E5 253-857-7055 Title :4' Unrestrained 40 psf Surcharge Job # :Dsgnr:JEH Page : 2 Description.... 4' Unrestrained wall with 40 psf surcharge This Wall in File: c:\users\johnhodge\documents\retainpro 10 project files\unrestrained walls 2.rpx RetainPro (c) 1987-2016, Build 11.16.06.24 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13License : KW-06053958LicenseTo:HODGE ENGINEERING Concrete Stem Rebar Area Details 3rd Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) :0.0002 in2/ft (4/3) * As :0.0003 in2/ft Min Stem T&S Reinf Area 0.192 in2 200bd/fy : 200(12)(4)/60000 :0.16 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.192 in2/ft 0.0018bh : 0.0018(12)(8) :0.1728 in2/ft Horizontal Reinforcing Options : ============One layer of : Two layers of : Required Area :0.1728 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area :0.2 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area :0.5419 in2/ft #6@ 27.50 in #6@ 55.00 in ________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ 2nd Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) :0.0207 in2/ft (4/3) * As :0.0277 in2/ft Min Stem T&S Reinf Area 0.480 in2 200bd/fy : 200(12)(4)/60000 :0.16 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.192 in2/ft 0.0018bh : 0.0018(12)(8) :0.1728 in2/ft Horizontal Reinforcing Options : ============One layer of : Two layers of : Required Area :0.1728 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area :0.2 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area :0.5419 in2/ft #6@ 27.50 in #6@ 55.00 in ________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) :0.0374 in2/ft (4/3) * As :0.0498 in2/ft Min Stem T&S Reinf Area 0.192 in2 200bd/fy : 200(12)(4)/60000 :0.16 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.192 in2/ft 0.0018bh : 0.0018(12)(8) :0.1728 in2/ft Horizontal Reinforcing Options : ============One layer of : Two layers of : Required Area :0.1728 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area :0.2 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area :0.5419 in2/ft #6@ 27.50 in #6@ 55.00 in 0.67 1.34 8.00 0.00 0.00 =Min. As %0.0018 Footing Dimensions & Strengths f'c=2,500psi Toe Width =ft Heel Width = Key Distance from Toe Key Depth Key Width =in =in =0.79 Footing Thickness =in 2.01= ft Cover @ Top =2.00 in@ Btm.=3.00in Total Footing Width =150.00pcfFooting Concrete Density Fy=60,000psi Footing Design Results Key: = No key defined Factored Pressure Mu' : Upward Mu' : Downward Mu: Design Actual 1-Way Shear Allow 1-Way Shear Toe:Not req'd: Mu < phi*5*lambda*sqrt(f'c)*Sm Not req'd: Mu < phi*5*lambda*sqrt(f'c)*Sm =# 4 @ 14.14 in = = = = = 2,100 398 57 341 8.69 75.00 Heel: 0 0 161 161 7.21 75.00 HeelToe psf ft-# ft-# ft-# psi psi Heel Reinforcing =None Spec'd Other Acceptable Sizes & Spacings Key Reinforcing Toe Reinforcing =None Spec'd Min footing T&S reinf Area Min footing T&S reinf Area per foot If one layer of horizontal bars: 0.35 0.17 #4@ 13.89 in #5@ 21.53 in #6@ 30.56 in in2 in2 /ft If two layers of horizontal bars: #4@ 27.78 in #5@ 43.06 in #6@ 61.11 in Page 58 of 68 Hodge Engineering, Inc. 2615 Jahn Ave NW Gig Harbor, WA STe. E5 253-857-7055 Title :4' Unrestrained 40 psf Surcharge Job # :Dsgnr:JEH Page : 3 Description.... 4' Unrestrained wall with 40 psf surcharge This Wall in File: c:\users\johnhodge\documents\retainpro 10 project files\unrestrained walls 2.rpx RetainPro (c) 1987-2016, Build 11.16.06.24 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13License : KW-06053958LicenseTo:HODGE ENGINEERING Summary of Overturning & Resisting Forces & Moments .....RESISTING..........OVERTURNING.....Force Distance Moment Distance Moment Item Force ft-#lbs ftft Heel Active Pressure = 381.1 1.56 592.8 Soil Over Heel =295.6 1.67 494.9 ft-#lbs Sloped Soil Over Heel138.62.3359.4=Surcharge over Heel = Surcharge Over Heel = 26.9 1.67 45.0= Adjacent Footing Load =Adjacent Footing Load Axial Dead Load on Stem = =*Axial Live Load on Stem Soil Over Toe Surcharge Over Toe Surcharge Over Toe Load @ Stem Above Soil = = = 73.9 0.34 24.8= = = Stem Weight(s) = 450.0 1.01 452.3 Earth @ Stem Transitions =Footing Weight = 201.0 1.01 202.1 Key Weight = 0.79 Added Lateral Load lbs = 731.4 Vert. Component Total = 1,047.4 1,219.1 *Axial live load NOT included in total displayed, or used for overturningresistance, but is included for soil pressure calculation. Total =R.M. = 440.5 O.T.M. = Resisting/Overturning Ratio =1.67 Vertical Loads used for Soil Pressure =1,047.4lbs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only)0.056 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. Page 59 of 68 Hodge Engineering, Inc. 2615 Jahn Ave NW Gig Harbor, WA STe. E5 253-857-7055 Title :6' Unrestrained 40 psf Surcharge Job # :Dsgnr:JEH Page : 1 Description.... 6' Unrestrained wall This Wall in File: c:\users\johnhodge\documents\retainpro 10 project files\unrestrained walls 2.rpx RetainPro (c) 1987-2016, Build 11.16.06.24 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13License : KW-06053958LicenseTo:HODGE ENGINEERING 6.00 0.50 0.00 12.00 1,500.0 35.0 0.0 250.0 Criteria Soil Data Retained Height =ft Wall height above soil =ft Active Heel Pressure =psf/ftSlope Behind Wall Height of Soil over Toe in Water height over heel =ft = = 110.00= pcf = Soil Density, Heel = Passive Pressure = psf/ft Allow Soil Bearing = psf Soil Density, Toe 110.00pcf Footing||Soil Friction =0.350 Soil height to ignore for passive pressure = 0.00in Equivalent Fluid Pressure Method Surcharge Loads Adjacent Footing Load Load Type 40.0 Lateral Load = 0.0#/ft 0.0 0.0 0.0 0.0 Axial Load Applied to Stem Wall to Ftg CL Dist =0.00ft Wind on Exposed Stem psf0.0= Lateral Load Applied to Stem Surcharge Over Heel =psf Adjacent Footing Load =0.0lbs Axial Dead Load (Service Level) =lbs Footing Type Line Load Surcharge Over Toe psf Footing Width =0.00ft...Height to Top =0.00ft Eccentricity =0.00in...Height to Bottom = 0.00ft Used To Resist Sliding & Overturning Used for Sliding & Overturning = 0.0ft Axial Live Load = Base Above/Below Soil lbs = Axial Load Eccentricity ==Poisson's Ratio 0.300 at Back of Wall in (Service Level) Wind (W)= Design Summary Wall Stability Ratios Overturning =2.01OK Sliding =1.56OK Total Bearing Load =1,270lbs ...resultant ecc. =4.54in Soil Pressure @ Toe =847psf OK Soil Pressure @ Heel =0psf OK Allowable =1,500 psf Soil Pressure Less Than Allowable ACI Factored @ Toe =1,977psf ACI Factored @ Heel =0psf Footing Shear @ Toe =17.6psi OK Footing Shear @ Heel =11.9psi OK Allowable =75.0psi Sliding Calcs Lateral Sliding Force =883.3lbs less 100% Passive Force less 100% Friction Force Added Force Req'd ....for 1.5 Stability = 0.0= 740.7 632.8 = = 0.0 - lbs lbs lbs OK lbs OK - Masonry Block Type =Medium Weight Stem Construction 3rd 2nd Bar Lap/EmbStem OK Stem OK Bottom Design Height Above Ftg =3.50ft 1.00 0.00 Wall Material Above "Ht" =Concrete Concrete Concrete Thickness =8.00 8.00 8.00 Rebar Size =###4 4 4 Rebar Spacing = 12.00 12.00 12.00 Rebar Placed at =Center Center Center Design Data fb/FB + fa/Fa =0.062 0.420 0.563 Total Force @ Section =l bs Moment....Actual =ft-# Moment.....Allowable =3,387.6 3,387.6 3,387.6ft-# Shear.....Actual =p si Shear.....Allowable =75.0 75.0psi 75.0 Wall Weight = 100.0 100.0psf 100.0 Rebar Depth 'd'= 4.00in 4.00 4.00 Masonry Data f'm =psi Fs =psi Solid Grouting = Modular Ratio 'n'= Short Term Factor = Equiv. Solid Thick.= Concrete Data f'c =2,500.0 2,500.0psi 2,500.0 Fy =60,000.0 60,000.0 Masonry Design Method ASD= Load Factors Building Code IBC 2015,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 psi 60,000.0 Service Level = 225.9 801.8lbs 892.2Strength Level Service Level Strength Level = 209.5 1,421.2 1,906.5ft-# Service Level Strength Level = 4.7 16.7 18.6psi Design Method = LRFD LRFD LRFD Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing Page 60 of 68 Hodge Engineering, Inc. 2615 Jahn Ave NW Gig Harbor, WA STe. E5 253-857-7055 Title :6' Unrestrained 40 psf Surcharge Job # :Dsgnr:JEH Page : 2 Description.... 6' Unrestrained wall This Wall in File: c:\users\johnhodge\documents\retainpro 10 project files\unrestrained walls 2.rpx RetainPro (c) 1987-2016, Build 11.16.06.24 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13License : KW-06053958LicenseTo:HODGE ENGINEERING Concrete Stem Rebar Area Details 3rd Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) :0.0126 in2/ft (4/3) * As :0.0169 in2/ft Min Stem T&S Reinf Area 0.576 in2 200bd/fy : 200(12)(4)/60000 :0.16 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.192 in2/ft 0.0018bh : 0.0018(12)(8) :0.1728 in2/ft Horizontal Reinforcing Options : ============One layer of : Two layers of : Required Area :0.1728 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area :0.2 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area :0.5419 in2/ft #6@ 27.50 in #6@ 55.00 in ________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ 2nd Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) :0.0858 in2/ft (4/3) * As :0.1144 in2/ft Min Stem T&S Reinf Area 0.480 in2 200bd/fy : 200(12)(4)/60000 :0.16 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.192 in2/ft 0.0018bh : 0.0018(12)(8) :0.1728 in2/ft Horizontal Reinforcing Options : ============One layer of : Two layers of : Required Area :0.1728 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area :0.2 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area :0.5419 in2/ft #6@ 27.50 in #6@ 55.00 in ________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) :0.1151 in2/ft (4/3) * As :0.1535 in2/ft Min Stem T&S Reinf Area 0.192 in2 200bd/fy : 200(12)(4)/60000 :0.16 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.192 in2/ft 0.0018bh : 0.0018(12)(8) :0.1728 in2/ft Horizontal Reinforcing Options : ============One layer of : Two layers of : Required Area :0.1728 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area :0.2 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area :0.5419 in2/ft #6@ 27.50 in #6@ 55.00 in 1.30 1.96 9.00 8.00 6.00 =Min. As %0.0018 Footing Dimensions & Strengths f'c=2,500psi Toe Width =ft Heel Width = Key Distance from Toe Key Depth Key Width =in =in =1.30 Footing Thickness =in 3.26= ft Cover @ Top =2.00 in@ Btm.=3.00in Total Footing Width =150.00pcfFooting Concrete Density Fy=60,000psi Footing Design Results Key: = #4@ 13.89 in, #5@ 21.53 in, #6@ 30.56 in, #7@ 41.67 in, Factored Pressure Mu' : Upward Mu' : Downward Mu: Design Actual 1-Way Shear Allow 1-Way Shear Toe:Not req'd: Mu < phi*5*lambda*sqrt(f'c)*Sm Not req'd: Mu < phi*5*lambda*sqrt(f'c)*Sm =# 4 @ 13.89 in = = = = = 1,977 1,421 224 1,197 17.64 75.00 Heel: 0 122 832 710 11.94 75.00 HeelToe psf ft-# ft-# ft-# psi psi Heel Reinforcing =None Spec'd Other Acceptable Sizes & Spacings Key Reinforcing Toe Reinforcing =None Spec'd Min footing T&S reinf Area Min footing T&S reinf Area per foot If one layer of horizontal bars: 0.63 0.19 #4@ 12.35 in #5@ 19.14 in #6@ 27.16 in in2 in2 /ft If two layers of horizontal bars: #4@ 24.69 in #5@ 38.27 in #6@ 54.32 in Page 61 of 68 Hodge Engineering, Inc. 2615 Jahn Ave NW Gig Harbor, WA STe. E5 253-857-7055 Title :6' Unrestrained 40 psf Surcharge Job # :Dsgnr:JEH Page : 3 Description.... 6' Unrestrained wall This Wall in File: c:\users\johnhodge\documents\retainpro 10 project files\unrestrained walls 2.rpx RetainPro (c) 1987-2016, Build 11.16.06.24 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13License : KW-06053958LicenseTo:HODGE ENGINEERING Summary of Overturning & Resisting Forces & Moments .....RESISTING..........OVERTURNING.....Force Distance Moment Distance Moment Item Force ft-#lbs ftft Heel Active Pressure = 797.3 2.25 1,794.0 Soil Over Heel =855.2 2.61 2,232.4 ft-#lbs Sloped Soil Over Heel289.93.3885.9=Surcharge over Heel = Surcharge Over Heel = 51.8 2.61 135.3= Adjacent Footing Load =Adjacent Footing Load Axial Dead Load on Stem = =*Axial Live Load on Stem Soil Over Toe Surcharge Over Toe Surcharge Over Toe Load @ Stem Above Soil = = = 142.5 0.65 92.3= = = Stem Weight(s) = 650.0 1.63 1,058.9 Earth @ Stem Transitions =Footing Weight = 366.6 1.63 597.2 Key Weight = 50.0 1.63 81.5 Added Lateral Load lbs = 2,084.0 Vert. Component Total = 2,116.1 4,197.6 *Axial live load NOT included in total displayed, or used for overturningresistance, but is included for soil pressure calculation. Total =R.M. = 883.3 O.T.M. = Resisting/Overturning Ratio =2.01 Vertical Loads used for Soil Pressure =2,116.1lbs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only)0.047 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. Page 62 of 68 Hodge Engineering, Inc. 2615 Jahn Ave NW Gig Harbor, WA STe. E5 253-857-7055 Title :8' Unrestrained 40 psf Surcharge Job # :Dsgnr:JEH Page : 1 Description.... 8' Unrestrained wall 40 psf surcharge This Wall in File: c:\users\johnhodge\documents\retainpro 10 project files\unrestrained walls 2.rpx RetainPro (c) 1987-2016, Build 11.16.06.24 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13License : KW-06053958LicenseTo:HODGE ENGINEERING 8.00 0.50 0.00 12.00 1,500.0 35.0 0.0 250.0 Criteria Soil Data Retained Height =ft Wall height above soil =ft Active Heel Pressure =psf/ftSlope Behind Wall Height of Soil over Toe in Water height over heel =ft = = 110.00= pcf = Soil Density, Heel = Passive Pressure = psf/ft Allow Soil Bearing = psf Soil Density, Toe 110.00pcf Footing||Soil Friction =0.350 Soil height to ignore for passive pressure = 0.00in Equivalent Fluid Pressure Method Surcharge Loads Adjacent Footing Load Load Type 40.0 Lateral Load = 0.0#/ft 0.0 0.0 0.0 0.0 Axial Load Applied to Stem Wall to Ftg CL Dist =0.00ft Wind on Exposed Stem psf0.0= Lateral Load Applied to Stem Surcharge Over Heel =psf Adjacent Footing Load =0.0lbs Axial Dead Load (Service Level) =lbs Footing Type Line Load Surcharge Over Toe psf Footing Width =0.00ft...Height to Top =0.00ft Eccentricity =0.00in...Height to Bottom = 0.00ft Used To Resist Sliding & Overturning Used for Sliding & Overturning = 0.0ft Axial Live Load = Base Above/Below Soil lbs = Axial Load Eccentricity ==Poisson's Ratio 0.300 at Back of Wall in (Service Level) Wind (W)= Design Summary Wall Stability Ratios Overturning =2.34OK Sliding =1.51OK Total Bearing Load =2,253lbs ...resultant ecc. =4.83in Soil Pressure @ Toe =874psf OK Soil Pressure @ Heel =73psf OK Allowable =1,500 psf Soil Pressure Less Than Allowable ACI Factored @ Toe =2,040psf ACI Factored @ Heel =170psf Footing Shear @ Toe =18.6psi OK Footing Shear @ Heel =13.1psi OK Allowable =75.0psi Sliding Calcs Lateral Sliding Force =1,532.0lbs less 100% Passive Force less 100% Friction Force Added Force Req'd ....for 1.5 Stability = 0.0= 1,314.0 1,003.5 = = 0.0 - lbs lbs lbs OK lbs OK - Masonry Block Type =Medium Weight Stem Construction 3rd 2nd Bar Lap/EmbStem OK Stem OK Bottom Design Height Above Ftg =3.50ft 1.00 0.00 Wall Material Above "Ht" =Concrete Concrete Concrete Thickness =8.00 8.00 8.00 Rebar Size =###5 5 5 Rebar Spacing = 12.00 12.00 10.75 Rebar Placed at =Center Center Center Design Data fb/FB + fa/Fa =0.208 0.730 0.769 Total Force @ Section =l bs Moment....Actual =ft-# Moment.....Allowable =5,069.7 5,069.7 5,593.0ft-# Shear.....Actual =p si Shear.....Allowable =75.0 75.0psi 75.0 Wall Weight = 100.0 100.0psf 100.0 Rebar Depth 'd'= 4.00in 4.00 4.00 Masonry Data f'm =psi Fs =psi Solid Grouting = Modular Ratio 'n'= Short Term Factor = Equiv. Solid Thick.= Concrete Data f'c =2,500.0 2,500.0psi 2,500.0 Fy =60,000.0 60,000.0 Masonry Design Method ASD= Load Factors Building Code IBC 2015,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 psi 60,000.0 Service Level = 658.6 1,514.5lbs 1,531.8Strength Level Service Level Strength Level = 1,056.7 3,700.2 4,302.0ft-# Service Level Strength Level = 13.7 31.6 31.9psi Design Method = LRFD LRFD LRFD Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing Page 63 of 68 Hodge Engineering, Inc. 2615 Jahn Ave NW Gig Harbor, WA STe. E5 253-857-7055 Title :8' Unrestrained 40 psf Surcharge Job # :Dsgnr:JEH Page : 2 Description.... 8' Unrestrained wall 40 psf surcharge This Wall in File: c:\users\johnhodge\documents\retainpro 10 project files\unrestrained walls 2.rpx RetainPro (c) 1987-2016, Build 11.16.06.24 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13License : KW-06053958LicenseTo:HODGE ENGINEERING Concrete Stem Rebar Area Details 3rd Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) :0.0638 in2/ft (4/3) * As :0.0851 in2/ft Min Stem T&S Reinf Area 0.960 in2 200bd/fy : 200(12)(4)/60000 :0.16 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.192 in2/ft 0.0018bh : 0.0018(12)(8) :0.1728 in2/ft Horizontal Reinforcing Options : ============One layer of : Two layers of : Required Area :0.1728 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area :0.31 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area :0.5419 in2/ft #6@ 27.50 in #6@ 55.00 in ________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ 2nd Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) :0.2234 in2/ft (4/3) * As :0.2978 in2/ft Min Stem T&S Reinf Area 0.480 in2 200bd/fy : 200(12)(4)/60000 :0.16 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.192 in2/ft 0.0018bh : 0.0018(12)(8) :0.1728 in2/ft Horizontal Reinforcing Options : ============One layer of : Two layers of : Required Area :0.2234 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area :0.31 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area :0.5419 in2/ft #6@ 27.50 in #6@ 55.00 in ________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) :0.2597 in2/ft (4/3) * As :0.3463 in2/ft Min Stem T&S Reinf Area 0.192 in2 200bd/fy : 200(12)(4)/60000 :0.16 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.192 in2/ft 0.0018bh : 0.0018(12)(8) :0.1728 in2/ft Horizontal Reinforcing Options : ============One layer of : Two layers of : Required Area :0.2597 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area :0.346 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area :0.5419 in2/ft #6@ 27.50 in #6@ 55.00 in 2.05 2.71 12.00 8.00 10.00 =Min. As %0.0018 Footing Dimensions & Strengths f'c=2,500psi Toe Width =ft Heel Width = Key Distance from Toe Key Depth Key Width =in =in =2.05 Footing Thickness =in 4.76= ft Cover @ Top =2.00 in@ Btm.=3.00in Total Footing Width =150.00pcfFooting Concrete Density Fy=60,000psi Footing Design Results Key: = #4@ 13.89 in, #5@ 21.53 in, #6@ 30.56 in, #7@ 41.67 in, Factored Pressure Mu' : Upward Mu' : Downward Mu: Design Actual 1-Way Shear Allow 1-Way Shear Toe:#4@ 9.26 in, #5@ 14.35 in, #6@ 20.37 in, #7@ 27.78 in, #8@ 36.57 in, #9@ 46 Not req'd: Mu < phi*5*lambda*sqrt(f'c)*Sm =# 4 @ 13.89 in = = = = = 2,040 3,708 653 3,055 18.63 75.00 Heel: 170 916 2,721 1,805 13.07 75.00 HeelToe psf ft-# ft-# ft-# psi psi Heel Reinforcing =# 4 @ 18.00 in Other Acceptable Sizes & Spacings Key Reinforcing Toe Reinforcing =# 4 @ 9.26 in Min footing T&S reinf Area Min footing T&S reinf Area per foot If one layer of horizontal bars: 1.23 0.26 #4@ 9.26 in #5@ 14.35 in #6@ 20.37 in in2 in2 /ft If two layers of horizontal bars: #4@ 18.52 in #5@ 28.70 in #6@ 40.74 in Page 64 of 68 Hodge Engineering, Inc. 2615 Jahn Ave NW Gig Harbor, WA STe. E5 253-857-7055 Title :8' Unrestrained 40 psf Surcharge Job # :Dsgnr:JEH Page : 3 Description.... 8' Unrestrained wall 40 psf surcharge This Wall in File: c:\users\johnhodge\documents\retainpro 10 project files\unrestrained walls 2.rpx RetainPro (c) 1987-2016, Build 11.16.06.24 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13License : KW-06053958LicenseTo:HODGE ENGINEERING Summary of Overturning & Resisting Forces & Moments .....RESISTING..........OVERTURNING.....Force Distance Moment Distance Moment Item Force ft-#lbs ftft Heel Active Pressure = 1,417.5 3.00 4,252.5 Soil Over Heel =1,800.3 3.74 6,725.0 ft-#lbs Sloped Soil Over Heel515.54.50114.5=Surcharge over Heel = Surcharge Over Heel = 81.8 3.74 305.7= Adjacent Footing Load =Adjacent Footing Load Axial Dead Load on Stem = =*Axial Live Load on Stem Soil Over Toe Surcharge Over Toe Surcharge Over Toe Load @ Stem Above Soil = = = 225.0 1.02 230.2= = = Stem Weight(s) = 850.0 2.38 2,022.3 Earth @ Stem Transitions =Footing Weight = 713.8 2.38 1,698.1 Key Weight = 83.3 2.38 198.3 Added Lateral Load lbs = 4,768.0 Vert. Component Total = 3,754.3 11,179.6 *Axial live load NOT included in total displayed, or used for overturningresistance, but is included for soil pressure calculation. Total =R.M. = 1,532.0 O.T.M. = Resisting/Overturning Ratio =2.34 Vertical Loads used for Soil Pressure =3,754.3lbs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only)0.043 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. Page 65 of 68 Hodge Engineering, Inc. 2615 Jahn Ave NW Gig Harbor, WA STe. E5 253-857-7055 Title :10' Unrestrained 40 psf Surcharge Job # :Dsgnr:JEH Page : 1 Description.... 10' Unrestrained wall with 40 psf surcharge This Wall in File: c:\users\johnhodge\documents\retainpro 10 project files\unrestrained walls 2.rpx RetainPro (c) 1987-2016, Build 11.16.06.24 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13License : KW-06053958LicenseTo:HODGE ENGINEERING 10.00 0.50 0.00 12.00 1,500.0 35.0 0.0 250.0 Criteria Soil Data Retained Height =ft Wall height above soil =ft Active Heel Pressure =psf/ftSlope Behind Wall Height of Soil over Toe in Water height over heel =ft = = 110.00= pcf = Soil Density, Heel = Passive Pressure = psf/ft Allow Soil Bearing = psf Soil Density, Toe 110.00pcf Footing||Soil Friction =0.350 Soil height to ignore for passive pressure = 0.00in Equivalent Fluid Pressure Method Surcharge Loads Adjacent Footing Load Load Type 40.0 Lateral Load = 0.0#/ft 0.0 0.0 0.0 0.0 Axial Load Applied to Stem Wall to Ftg CL Dist =0.00ft Wind on Exposed Stem psf0.0= Lateral Load Applied to Stem Surcharge Over Heel =psf Adjacent Footing Load =0.0lbs Axial Dead Load (Service Level) =lbs Footing Type Line Load Surcharge Over Toe psf Footing Width =0.00ft...Height to Top =0.00ft Eccentricity =0.00in...Height to Bottom = 0.00ft Used To Resist Sliding & Overturning Used for Sliding & Overturning = 0.0ft Axial Live Load = Base Above/Below Soil lbs = Axial Load Eccentricity ==Poisson's Ratio 0.300 at Back of Wall in (Service Level) Wind (W)= Design Summary Wall Stability Ratios Overturning =2.65OK Sliding =1.52OK Total Bearing Load =3,375lbs ...resultant ecc. =4.54in Soil Pressure @ Toe =865psf OK Soil Pressure @ Heel =213psf OK Allowable =1,500 psf Soil Pressure Less Than Allowable ACI Factored @ Toe =2,019psf ACI Factored @ Heel =497psf Footing Shear @ Toe =28.8psi OK Footing Shear @ Heel =17.8psi OK Allowable =75.0psi Sliding Calcs Lateral Sliding Force =2,257.5lbs less 100% Passive Force less 100% Friction Force Added Force Req'd ....for 1.5 Stability = 0.0= 1,968.8 1,459.2 = = 0.0 - lbs lbs lbs OK lbs OK - Masonry Block Type =Medium Weight Stem Construction 3rd 2nd Bar Lap/EmbStem OK Stem OK Bottom Design Height Above Ftg =3.50ft 1.00 0.00 Wall Material Above "Ht" =Concrete Concrete Concrete Thickness =8.00 8.00 8.00 Rebar Size =###5 5 5 Rebar Spacing = 10.00 10.00 9.00 Rebar Placed at =Edge Edge Edge Design Data fb/FB + fa/Fa =0.311 0.793 0.769 Total Force @ Section =l bs Moment....Actual =ft-# Moment.....Allowable =9,623.1 9,623.1 10,601.6ft-# Shear.....Actual =p si Shear.....Allowable =75.0 75.0psi 75.0 Wall Weight = 100.0 100.0psf 100.0 Rebar Depth 'd'= 6.19in 6.19 6.19 Masonry Data f'm =psi Fs =psi Solid Grouting = Modular Ratio 'n'= Short Term Factor = Equiv. Solid Thick.= Concrete Data f'c =2,500.0 2,500.0psi 2,500.0 Fy =60,000.0 60,000.0 Masonry Design Method ASD= Load Factors Building Code IBC 2015,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 psi 60,000.0 Service Level = 1,315.4 2,451.3lbs 2,342.5Strength Level Service Level Strength Level = 2,993.3 7,628.7 8,147.8ft-# Service Level Strength Level = 17.7 33.0 31.5psi Design Method = LRFD LRFD LRFD Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing Page 66 of 68 Hodge Engineering, Inc. 2615 Jahn Ave NW Gig Harbor, WA STe. E5 253-857-7055 Title :10' Unrestrained 40 psf Surcharge Job # :Dsgnr:JEH Page : 2 Description.... 10' Unrestrained wall with 40 psf surcharge This Wall in File: c:\users\johnhodge\documents\retainpro 10 project files\unrestrained walls 2.rpx RetainPro (c) 1987-2016, Build 11.16.06.24 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13License : KW-06053958LicenseTo:HODGE ENGINEERING Concrete Stem Rebar Area Details 3rd Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) :0.1133 in2/ft (4/3) * As :0.1511 in2/ft Min Stem T&S Reinf Area 1.344 in2 200bd/fy : 200(12)(6.1875)/60000 :0.2475 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.192 in2/ft 0.0018bh : 0.0018(12)(8) :0.1728 in2/ft Horizontal Reinforcing Options : ============One layer of : Two layers of : Required Area :0.1728 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area :0.372 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area :0.8382 in2/ft #6@ 27.50 in #6@ 55.00 in ________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ 2nd Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) :0.2889 in2/ft (4/3) * As :0.3852 in2/ft Min Stem T&S Reinf Area 0.480 in2 200bd/fy : 200(12)(6.1875)/60000 :0.2475 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.192 in2/ft 0.0018bh : 0.0018(12)(8) :0.1728 in2/ft Horizontal Reinforcing Options : ============One layer of : Two layers of : Required Area :0.2889 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area :0.372 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area :0.8382 in2/ft #6@ 27.50 in #6@ 55.00 in ________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) :0.3085 in2/ft (4/3) * As :0.4114 in2/ft Min Stem T&S Reinf Area 0.192 in2 200bd/fy : 200(12)(6.1875)/60000 :0.2475 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.192 in2/ft 0.0018bh : 0.0018(12)(8) :0.1728 in2/ft Horizontal Reinforcing Options : ============One layer of : Two layers of : Required Area :0.3085 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area :0.4133 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area :0.8382 in2/ft #6@ 27.50 in #6@ 55.00 in 2.80 3.46 12.00 8.00 17.00 =Min. As %0.0018 Footing Dimensions & Strengths f'c=2,500psi Toe Width =ft Heel Width = Key Distance from Toe Key Depth Key Width =in =in =2.80 Footing Thickness =in 6.26= ft Cover @ Top =2.00 in@ Btm.=3.00in Total Footing Width =150.00pcfFooting Concrete Density Fy=60,000psi Footing Design Results Key: = #4@ 13.89 in, #5@ 21.53 in, #6@ 30.56 in, #7@ 41.67 in, Factored Pressure Mu' : Upward Mu' : Downward Mu: Design Actual 1-Way Shear Allow 1-Way Shear Toe:#4@ 9.26 in, #5@ 14.35 in, #6@ 20.37 in, #7@ 27.78 in, #8@ 36.57 in, #9@ 46 #4@ 9.26 in, #5@ 14.35 in, #6@ 20.37 in, #7@ 27.78 in, #8@ 36.57 in, #9@ 46 =# 5 @ 21.53 in = = = = = 2,019 7,007 1,219 5,787 28.85 75.00 Heel: 497 2,829 6,113 3,283 17.82 75.00 HeelToe psf ft-# ft-# ft-# psi psi Heel Reinforcing =None Spec'd Other Acceptable Sizes & Spacings Key Reinforcing Toe Reinforcing =None Spec'd Min footing T&S reinf Area Min footing T&S reinf Area per foot If one layer of horizontal bars: 1.62 0.26 #4@ 9.26 in #5@ 14.35 in #6@ 20.37 in in2 in2 /ft If two layers of horizontal bars: #4@ 18.52 in #5@ 28.70 in #6@ 40.74 in Page 67 of 68 Hodge Engineering, Inc. 2615 Jahn Ave NW Gig Harbor, WA STe. E5 253-857-7055 Title :10' Unrestrained 40 psf Surcharge Job # :Dsgnr:JEH Page : 3 Description.... 10' Unrestrained wall with 40 psf surcharge This Wall in File: c:\users\johnhodge\documents\retainpro 10 project files\unrestrained walls 2.rpx RetainPro (c) 1987-2016, Build 11.16.06.24 Cantilevered Retaining Wall Code: IBC 2015,ACI 318-14,ACI 530-13License : KW-06053958LicenseTo:HODGE ENGINEERING Summary of Overturning & Resisting Forces & Moments .....RESISTING..........OVERTURNING.....Force Distance Moment Distance Moment Item Force ft-#lbs ftft Heel Active Pressure = 2,117.5 3.67 7,764.2 Soil Over Heel =3,075.4 4.86 14,947.8 ft-#lbs Sloped Soil Over Heel770.05.50140.0=Surcharge over Heel = Surcharge Over Heel = 111.8 4.86 543.6= Adjacent Footing Load =Adjacent Footing Load Axial Dead Load on Stem = =*Axial Live Load on Stem Soil Over Toe Surcharge Over Toe Surcharge Over Toe Load @ Stem Above Soil = = = 307.5 1.40 429.9= = = Stem Weight(s) = 1,050.0 3.13 3,285.6 Earth @ Stem Transitions =Footing Weight = 938.8 3.13 2,937.5 Key Weight = 141.7 3.13 443.3 Added Lateral Load lbs = 8,534.2 Vert. Component Total = 5,625.2 22,587.7 *Axial live load NOT included in total displayed, or used for overturningresistance, but is included for soil pressure calculation. Total =R.M. = 2,257.5 O.T.M. = Resisting/Overturning Ratio =2.65 Vertical Loads used for Soil Pressure =5,625.2lbs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only)0.040 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. Page 68 of 68