2021.0011 Plan D1320-1-1320-1 Structural AnalysisENGINEERING ANALYSIS FOR:
NEW DUPLEX
15603 VIEW DRIVE SW
YELM, WA 98597
DESIGN CRITERIA
BUILDING CODE: 2015 INTERNATIONAL BUILDING CODE (IBC) AS AMENDED BY THE
LOCAL JURISDICTION.
ROOF LIVE LOAD:25 PSF (SNOW)
ROOF DEAD LOAD:15 PSF
RESIDENTIAL FLOOR LIVE LOAD:40 PSF (REDUCIBLE) : 60 PSF (FOR DECKS)
FLOOR DEAD LOAD:15 PSF
WIND LOAD:110 MPH (ASD)
EXPOSURE "B", RISK CATEGORY II, Kzt=1.0
SOIL SITE:CLASS "D"
SIESMIC CATAGORY:D, R=6.5, Sds=1.036, Ie=1.0
FROST DEPTH:12"PROJECTDRAWING TITLE15603 VIEW DRIVE SE, YELM, WA 98597STRUCTURAL ANALYSIS1/17/2021
3128 N. BENNETT ST.TACOMA, WA 98407PHONE: (206) 949-7866PIERUCCIONI E&C, LLCCHON PIERUCCIONI, PERAINIER GROUP CAPITAL LLC - CREEK ESTATES
Roof Framing
Member Name Results Current Solution Comments
6' Window Header Passed 1 piece(s) 4 x 10 Douglas Fir-Larch No. 2
4' Window Header Passed 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2
2nd Floor Framing
Member Name Results Current Solution Comments
Garage Door Header Passed 1 piece(s) 6 x 12 Hem-Fir No. 2
Front Garage Drop Floor Beam Passed 1 piece(s) 5 1/2" x 11 7/8" 24F-V4 DF Glulam
14' Floor Joist Passed 1 piece(s) 11 7/8" TJI® 110 @ 16" OC
Entry Flush Beam Passed 2 piece(s) 1 1/2" x 11 7/8" 1.5E TimberStrand® LSL
Back Garage Flush Beam Passed 1 piece(s) 3 1/2" x 11 7/8" 24F-V4 DF Glulam
Foyer Flush Beam Passed 2 piece(s) 1 1/2" x 11 7/8" 1.5E TimberStrand® LSL
Kitchen Flush Beam Passed 1 piece(s) 3 1/2" x 11 7/8" 24F-V4 DF Glulam
6' Door/Window Header Passed 1 piece(s) 4 x 12 Douglas Fir-Larch No. 2
Cantilever Floor Joist Passed 1 piece(s) 11 7/8" TJI® 110 @ 16" OC
1st Floor Framing
Member Name Results Current Solution Comments
Floor Joist Dimensional Passed 1 piece(s) 2 x 10 Hem-Fir No. 2 @ 16" OC
Floor Joist TJI Passed 1 piece(s) 9 1/2" TJI® 110 @ 16" OC
Floor: Drop Beam Passed 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2
Floor: Drop Beam ends Passed 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2
15638 View Dr SE, Yelm
JOB SUMMARY REPORT
ForteWEB Software Operator Job Notes 1/17/2021 7:43:48 PM UTC
Chon Pieruccioni
Pieruccioni Engineering
(206) 949-7866
cpieru@hotmail.com
ForteWEB v3.1
File Name: 15638 View Dr SE, Yelm
Page 1 / 17
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)2838 @ 0 3281 (1.50")Passed (86%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)2025 @ 10 3/4"4468 Passed (45%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)4435 @ 3' 1 1/2"5166 Passed (86%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.052 @ 3' 1 1/2"0.208 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.084 @ 3' 1 1/2"0.313 Passed (L/888)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Trimmer - HF 1.50"1.50"1.50"1080 1758 2838 None
2 - Trimmer - HF 1.50"1.50"1.50"1080 1758 2838 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)6' 3" o/c
Bottom Edge (Lu)6' 3" o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 6' 3"N/A 8.2 --
1 - Uniform (PSF)0 to 6' 3"22' 6"15.0 25.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Roof Framing, 6' Window Header
1 piece(s) 4 x 10 Douglas Fir-Larch No. 2
ForteWEB Software Operator Job Notes 1/17/2021 7:43:48 PM UTC
Chon Pieruccioni
Pieruccioni Engineering
(206) 949-7866
cpieru@hotmail.com
ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0
File Name: 15638 View Dr SE, Yelm
Page 2 / 17
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)1926 @ 0 3281 (1.50")Passed (59%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)1265 @ 8 3/4"3502 Passed (36%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)2047 @ 2' 1 1/2"3438 Passed (60%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.023 @ 2' 1 1/2"0.142 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.037 @ 2' 1 1/2"0.213 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Trimmer - HF 1.50"1.50"1.50"731 1195 1926 None
2 - Trimmer - HF 1.50"1.50"1.50"731 1195 1926 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)4' 3" o/c
Bottom Edge (Lu)4' 3" o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 4' 3"N/A 6.4 --
1 - Uniform (PSF)0 to 4' 3"22' 6"15.0 25.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Roof Framing, 4' Window Header
1 piece(s) 4 x 8 Douglas Fir-Larch No. 2
ForteWEB Software Operator Job Notes 1/17/2021 7:43:48 PM UTC
Chon Pieruccioni
Pieruccioni Engineering
(206) 949-7866
cpieru@hotmail.com
ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0
File Name: 15638 View Dr SE, Yelm
Page 3 / 17
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)566 @ 1 1/2"6683 (3.00")Passed (8%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)422 @ 1' 2 1/2"6789 Passed (6%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)1274 @ 4' 9"7842 Passed (16%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.013 @ 4' 9"0.308 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.026 @ 4' 9"0.463 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Total Accessories
1 - Trimmer - HF 3.00"3.00"1.50"269 297 566 None
2 - Trimmer - HF 3.00"3.00"1.50"269 297 566 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)9' 6" o/c
Bottom Edge (Lu)9' 6" o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 9' 6"N/A 16.0 --
1 - Uniform (PSF)0 to 9' 6"2' 6"16.2 25.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
2nd Floor Framing, Garage Door Header
1 piece(s) 6 x 12 Hem-Fir No. 2
ForteWEB Software Operator Job Notes 1/17/2021 7:43:48 PM UTC
Chon Pieruccioni
Pieruccioni Engineering
(206) 949-7866
cpieru@hotmail.com
ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0
File Name: 15638 View Dr SE, Yelm
Page 4 / 17
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)7076 @ 4"12251 (5.50")Passed (58%)--1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (lbs)5394 @ 1' 5 3/8"13269 Passed (41%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans)
Pos Moment (Ft-lbs)11550 @ 4' 4 5/8"29731 Passed (39%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans)
Live Load Defl. (in)0.118 @ 5' 8 13/16"0.378 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)0.195 @ 5' 8 1/2"0.567 Passed (L/697)--1.0 D + 0.75 L + 0.75 S (All Spans)
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 11' 4".
•The effects of positive or negative camber have not been accounted for when calculating deflection.
•The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
•Applicable calculations are based on NDS.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Stud wall - HF 5.50"5.50"3.18"2940 2060 3454 8454 Blocking
2 - Stud wall - HF 5.50"5.50"1.50"1265 2060 663 3988 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)12' o/c
Bottom Edge (Lu)12' o/c
Dead Floor Live Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)0 to 12'N/A 15.9 ----
1 - Uniform (PSF)0 to 12' (Front)8' 7"15.0 40.0 -Default Load
2 - Point (lb)2' 2 1/2" (Top)N/A 1650 -2750
3 - Uniform (PSF)0 to 2' (Front)22' 6"15.0 -25.0 Default Load
4 - Uniform (PSF)2' to 11' 8" (Front)1'15.0 -25.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
2nd Floor Framing, Front Garage Drop Floor Beam
1 piece(s) 5 1/2" x 11 7/8" 24F-V4 DF Glulam
ForteWEB Software Operator Job Notes 1/17/2021 7:43:48 PM UTC
Chon Pieruccioni
Pieruccioni Engineering
(206) 949-7866
cpieru@hotmail.com
ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0
File Name: 15638 View Dr SE, Yelm
Page 5 / 17
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)516 @ 14' 5 1/2"910 (1.75")Passed (57%)1.00 1.0 D + 1.0 L (All Spans)
Shear (lbs)516 @ 14' 5 1/2"1560 Passed (33%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)1818 @ 7' 5"3160 Passed (58%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.164 @ 7' 5"0.469 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.226 @ 7' 5"0.704 Passed (L/748)--1.0 D + 1.0 L (All Spans)
TJ-Pro™ Rating 50 40 Passed ----
System : Floor
Member Type : Joist
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•A structural analysis of the deck has not been performed.
• Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser Edge™ Panel (24" Span Rating) that is glued and nailed down.
• Additional considerations for the TJ-Pro™ Rating include: 1/2" Gypsum ceiling.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
• ¹ See Connector grid below for additional information and/or requirements.
• ² Required Bearing Length / Required Bearing Length with Web Stiffeners
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Stud wall - HF 5.50"5.50"1.75"148 396 544 Blocking
2 - Hanger on 11 7/8" GLB beam 3.50"Hanger¹1.75" / - ²147 391 538 See note ¹
•TJI joists are only analyzed using Maximum Allowable bracing solutions.
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)4' 2" o/c
Bottom Edge (Lu)14' 6" o/c
Connector: Simpson Strong-Tie
Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories
2 - Face Mount Hanger IUS1.81/11.88 2.00"N/A 10-10dx1.5 2-Strong-Grip
•Refer to manufacturer notes and instructions for proper installation and use of all connectors.
Dead Floor Live
Vertical Load Location (Side)Spacing (0.90)(1.00)Comments
1 - Uniform (PSF)0 to 14' 9"16"15.0 40.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
2nd Floor Framing, 14' Floor Joist
1 piece(s) 11 7/8" TJI® 110 @ 16" OC
ForteWEB Software Operator Job Notes 1/17/2021 7:43:48 PM UTC
Chon Pieruccioni
Pieruccioni Engineering
(206) 949-7866
cpieru@hotmail.com
ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0
File Name: 15638 View Dr SE, Yelm
Page 6 / 17
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)4025 @ 4"6683 (5.50")Passed (60%)--1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (lbs)2453 @ 1' 5 3/8"13793 Passed (18%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans)
Moment (Ft-lbs)6181 @ 3' 8 1/2"15218 Passed (41%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans)
Live Load Defl. (in)0.063 @ 3' 8 1/2"0.225 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)0.107 @ 3' 8 1/2"0.338 Passed (L/754)--1.0 D + 0.75 L + 0.75 S (All Spans)
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Stud wall - HF 5.50"5.50"3.31"1681 1038 2086 4805 Blocking
2 - Stud wall - HF 5.50"5.50"3.31"1681 1038 2086 4805 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)7' 5" o/c
Bottom Edge (Lu)7' 5" o/c
Dead Floor Live Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)0 to 7' 5"N/A 10.9 ----
1 - Uniform (PSF)0 to 7' 5" (Front)7'15.0 40.0 -Default Load
2 - Uniform (PSF)0 to 7' 5" (Front)22' 6"15.0 -25.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
2nd Floor Framing, Entry Flush Beam
2 piece(s) 1 1/2" x 11 7/8" 1.5E TimberStrand® LSL
ForteWEB Software Operator Job Notes 1/17/2021 7:43:48 PM UTC
Chon Pieruccioni
Pieruccioni Engineering
(206) 949-7866
cpieru@hotmail.com
ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0
File Name: 15638 View Dr SE, Yelm
Page 7 / 17
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)4435 @ 11' 8"5670 (4.00")Passed (78%)--1.0 D + 1.0 L (All Spans)
Shear (lbs)3436 @ 1' 5 3/8"7343 Passed (47%)1.00 1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-lbs)12120 @ 6'16452 Passed (74%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.229 @ 6'0.378 Passed (L/595)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.319 @ 6'0.567 Passed (L/427)--1.0 D + 1.0 L (All Spans)
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 11' 4".
•The effects of positive or negative camber have not been accounted for when calculating deflection.
•The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
•Applicable calculations are based on NDS.
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Stud wall - HF 5.50"5.50"3.20"1279 3250 4529 Blocking
2 - Stud wall - HF 5.50"4.00"3.13"1278 3250 4528 1 1/2" Rim Board
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)11' 11" o/c
Bottom Edge (Lu)11' 11" o/c
Dead Floor Live
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments
0 - Self Weight (PLF)0 to 11' 10 1/2"N/A 10.1 --
1 - Uniform (PSF)0 to 12' (Front)13' 6 1/2"15.0 40.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
2nd Floor Framing, Back Garage Flush Beam
1 piece(s) 3 1/2" x 11 7/8" 24F-V4 DF Glulam
ForteWEB Software Operator Job Notes 1/17/2021 7:43:48 PM UTC
Chon Pieruccioni
Pieruccioni Engineering
(206) 949-7866
cpieru@hotmail.com
ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0
File Name: 15638 View Dr SE, Yelm
Page 8 / 17
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)2708 @ 4"4860 (4.00")Passed (56%)--1.0 D + 1.0 L (All Spans)
Shear (lbs)1708 @ 1' 5 3/8"11994 Passed (14%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)4304 @ 3' 8 1/2"13233 Passed (33%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.054 @ 3' 8 1/2"0.225 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.075 @ 3' 8 1/2"0.338 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Stud wall - HF 5.50"4.00"2.23"792 2009 2801 1 1/2" Rim Board
2 - Stud wall - HF 5.50"5.50"2.31"794 2009 2803 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)7' 4" o/c
Bottom Edge (Lu)7' 4" o/c
Dead Floor Live
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments
0 - Self Weight (PLF)1 1/2" to 7' 5"N/A 10.9 --
1 - Uniform (PSF)0 to 7' 5" (Front)13' 6 1/2"15.0 40.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
2nd Floor Framing, Foyer Flush Beam
2 piece(s) 1 1/2" x 11 7/8" 1.5E TimberStrand® LSL
ForteWEB Software Operator Job Notes 1/17/2021 7:43:48 PM UTC
Chon Pieruccioni
Pieruccioni Engineering
(206) 949-7866
cpieru@hotmail.com
ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0
File Name: 15638 View Dr SE, Yelm
Page 9 / 17
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)5136 @ 13' 1"5670 (4.00")Passed (91%)--1.0 D + 1.0 L (All Spans)
Shear (lbs)4104 @ 1' 5 3/8"7343 Passed (56%)1.00 1.0 D + 1.0 L (All Spans)
Pos Moment (Ft-lbs)15852 @ 6' 8 1/2"16452 Passed (96%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.379 @ 6' 8 1/2"0.425 Passed (L/404)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.528 @ 6' 8 1/2"0.637 Passed (L/290)--1.0 D + 1.0 L (All Spans)
System : Floor
Member Type : Flush Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 12' 9".
•The effects of positive or negative camber have not been accounted for when calculating deflection.
•The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
•Applicable calculations are based on NDS.
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Stud wall - HF 5.50"5.50"3.69"1477 3757 5234 Blocking
2 - Stud wall - HF 5.50"4.00"3.62"1475 3757 5232 1 1/2" Rim Board
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)9' 5" o/c
Bottom Edge (Lu)13' 4" o/c
Dead Floor Live
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments
0 - Self Weight (PLF)0 to 13' 3 1/2"N/A 10.1 --
1 - Uniform (PSF)0 to 13' 5" (Front)14'15.0 40.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
2nd Floor Framing, Kitchen Flush Beam
1 piece(s) 3 1/2" x 11 7/8" 24F-V4 DF Glulam
ForteWEB Software Operator Job Notes 1/17/2021 7:43:48 PM UTC
Chon Pieruccioni
Pieruccioni Engineering
(206) 949-7866
cpieru@hotmail.com
ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0
File Name: 15638 View Dr SE, Yelm
Page 10 / 17
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)3597 @ 1 1/2"6563 (3.00")Passed (55%)--1.0 D + 0.75 L + 0.75 S (All Spans)
Shear (lbs)2283 @ 1' 2 1/4"5434 Passed (42%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans)
Moment (Ft-lbs)5405 @ 3' 3"7004 Passed (77%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans)
Live Load Defl. (in)0.033 @ 3' 3"0.208 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans)
Total Load Defl. (in)0.057 @ 3' 3"0.313 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Trimmer - HF 3.00"3.00"1.64"1495 975 1828 4298 None
2 - Trimmer - HF 3.00"3.00"1.64"1495 975 1828 4298 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)6' 6" o/c
Bottom Edge (Lu)6' 6" o/c
Dead Floor Live Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments
0 - Self Weight (PLF)0 to 6' 6"N/A 10.0 ----
1 - Uniform (PSF)0 to 6' 6"22' 6"15.0 -25.0 Default Load
2 - Uniform (PSF)0 to 6' 6"7' 6"15.0 40.0 -Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
2nd Floor Framing, 6' Door/Window Header
1 piece(s) 4 x 12 Douglas Fir-Larch No. 2
ForteWEB Software Operator Job Notes 1/17/2021 7:43:48 PM UTC
Chon Pieruccioni
Pieruccioni Engineering
(206) 949-7866
cpieru@hotmail.com
ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0
File Name: 15638 View Dr SE, Yelm
Page 11 / 17
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)462 @ 15' 5 1/2"910 (1.75")Passed (51%)1.00 1.0 D + 1.0 L (Alt Spans)
Shear (lbs)462 @ 15' 5 1/2"1560 Passed (30%)1.00 1.0 D + 1.0 L (Alt Spans)
Moment (Ft-lbs)1457 @ 9' 1 7/8"3160 Passed (46%)1.00 1.0 D + 1.0 L (Alt Spans)
Live Load Defl. (in)0.130 @ 8' 10 1/8"0.441 Passed (L/999+)--1.0 D + 1.0 L (Alt Spans)
Total Load Defl. (in)0.162 @ 8' 11 1/2"0.661 Passed (L/978)--1.0 D + 1.0 L (Alt Spans)
TJ-Pro™ Rating 53 40 Passed ----
System : Floor
Member Type : Joist
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Overhang deflection criteria: LL (2L/360) and TL (2L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•A structural analysis of the deck has not been performed.
• Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser Edge™ Panel (24" Span Rating) that is glued and nailed down.
• Additional considerations for the TJ-Pro™ Rating include: 1/2" Gypsum ceiling.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
• ¹ See Connector grid below for additional information and/or requirements.
• ² Required Bearing Length / Required Bearing Length with Web Stiffeners
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Snow Total Accessories
1 - Beam - GLB 5.50"5.50"3.50"326 482 38 846 Blocking
2 - Hanger on 11 7/8" GLB beam 3.50"Hanger¹1.75" / - ²115 368 -5 483/-5 See note ¹
•TJI joists are only analyzed using Maximum Allowable bracing solutions.
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)4' 9" o/c
Bottom Edge (Lu)7' 4" o/c
Connector: Simpson Strong-Tie
Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories
2 - Face Mount Hanger IUS1.81/11.88 2.00"N/A 10-10dx1.5 2-Strong-Grip
•Refer to manufacturer notes and instructions for proper installation and use of all connectors.
Dead Floor Live Snow
Vertical Loads Location (Side)Spacing (0.90)(1.00)(1.15)Comments
1 - Uniform (PSF)0 to 15' 9"16"15.0 40.0 -Default Load
2 - Point (lb)2 3/4"N/A 126 -33
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
2nd Floor Framing, Cantilever Floor Joist
1 piece(s) 11 7/8" TJI® 110 @ 16" OC
ForteWEB Software Operator Job Notes 1/17/2021 7:43:48 PM UTC
Chon Pieruccioni
Pieruccioni Engineering
(206) 949-7866
cpieru@hotmail.com
ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0
File Name: 15638 View Dr SE, Yelm
Page 12 / 17
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
ForteWEB Software Operator Job Notes 1/17/2021 7:43:48 PM UTC
Chon Pieruccioni
Pieruccioni Engineering
(206) 949-7866
cpieru@hotmail.com
ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0
File Name: 15638 View Dr SE, Yelm
Page 13 / 17
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)471 @ 2 1/2"1215 (2.00")Passed (39%)--1.0 D + 1.0 L (All Spans)
Shear (lbs)402 @ 1' 3/4"1388 Passed (29%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)1471 @ 6' 6 1/2"1917 Passed (77%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.240 @ 6' 6 1/2"0.422 Passed (L/633)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.330 @ 6' 6 1/2"0.633 Passed (L/460)--1.0 D + 1.0 L (All Spans)
TJ-Pro™ Rating N/A N/A N/A --N/A
System : Floor
Member Type : Joist
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•A 15% increase in the moment capacity has been added to account for repetitive member usage.
•Applicable calculations are based on NDS.
•No composite action between deck and joist was considered in analysis.
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Plate on concrete - HF 3.50"2.00"1.50"131 349 480 1 1/2" Rim Board
2 - Beam - DF 3.50"3.50"1.50"131 349 480 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)5' 11" o/c
Bottom Edge (Lu)13' o/c
Dead Floor Live
Vertical Load Location (Side)Spacing (0.90)(1.00)Comments
1 - Uniform (PSF)0 to 13' 1"16"15.0 40.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
1st Floor Framing, Floor Joist Dimensional
1 piece(s) 2 x 10 Hem-Fir No. 2 @ 16" OC
ForteWEB Software Operator Job Notes 1/17/2021 7:43:48 PM UTC
Chon Pieruccioni
Pieruccioni Engineering
(206) 949-7866
cpieru@hotmail.com
ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0
File Name: 15638 View Dr SE, Yelm
Page 14 / 17
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)471 @ 2 1/2"976 (2.00")Passed (48%)1.00 1.0 D + 1.0 L (All Spans)
Shear (lbs)458 @ 3 1/2"1220 Passed (38%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)1471 @ 6' 6 1/2"2500 Passed (59%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.177 @ 6' 6 1/2"0.422 Passed (L/857)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.244 @ 6' 6 1/2"0.633 Passed (L/623)--1.0 D + 1.0 L (All Spans)
TJ-Pro™ Rating 41 40 Passed ----
System : Floor
Member Type : Joist
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•A structural analysis of the deck has not been performed.
• Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser Edge™ Panel (24" Span Rating) that is glued and nailed down.
• Additional considerations for the TJ-Pro™ Rating include: None.
• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Plate on concrete - HF 3.50"2.00"1.75"131 349 480 1 1/2" Rim Board
2 - Beam - DF 3.50"3.50"1.75"131 349 480 Blocking
•TJI joists are only analyzed using Maximum Allowable bracing solutions.
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)4' 1" o/c
Bottom Edge (Lu)13' o/c
Dead Floor Live
Vertical Load Location (Side)Spacing (0.90)(1.00)Comments
1 - Uniform (PSF)0 to 13' 1"16"15.0 40.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
1st Floor Framing, Floor Joist TJI
1 piece(s) 9 1/2" TJI® 110 @ 16" OC
ForteWEB Software Operator Job Notes 1/17/2021 7:43:48 PM UTC
Chon Pieruccioni
Pieruccioni Engineering
(206) 949-7866
cpieru@hotmail.com
ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0
File Name: 15638 View Dr SE, Yelm
Page 15 / 17
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)1722 @ 1 1/4"4091 (2.75")Passed (42%)--1.0 D + 1.0 L (All Spans)
Shear (lbs)1166 @ 10"3045 Passed (38%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)2048 @ 2' 7"2989 Passed (69%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.037 @ 2' 7"0.165 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
Total Load Defl. (in)0.051 @ 2' 7"0.248 Passed (L/999+)--1.0 D + 1.0 L (All Spans)
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Stud wall - SPF 2.75"2.75"1.50"482 1240 1722 Blocking
2 - Stud wall - SPF 2.75"2.75"1.50"482 1240 1722 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)5' 2" o/c
Bottom Edge (Lu)5' 2" o/c
Dead Floor Live
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments
0 - Self Weight (PLF)0 to 5' 2"N/A 6.4 --
1 - Uniform (PSF)0 to 5' 2" (Front)12'15.0 40.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
1st Floor Framing, Floor: Drop Beam
1 piece(s) 4 x 8 Douglas Fir-Larch No. 2
ForteWEB Software Operator Job Notes 1/17/2021 7:43:48 PM UTC
Chon Pieruccioni
Pieruccioni Engineering
(206) 949-7866
cpieru@hotmail.com
ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0
File Name: 15638 View Dr SE, Yelm
Page 16 / 17
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)3397 @ 5' 1"5206 (3.50")Passed (65%)--1.0 D + 1.0 L (All Spans)
Shear (lbs)1467 @ 4' 4"3045 Passed (48%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)1856 @ 2' 5 9/16"2989 Passed (62%)1.00 1.0 D + 1.0 L (Alt Spans)
Live Load Defl. (in)0.051 @ 7' 2 3/4"0.200 Passed (2L/999+)--1.0 D + 1.0 L (Alt Spans)
Total Load Defl. (in)0.050 @ 7' 2 3/4"0.215 Passed (2L/999+)--1.0 D + 1.0 L (Alt Spans)
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2015
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Overhang deflection criteria: LL (2L/0.2") and TL (2L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Total Accessories
1 - Stud wall - SPF 2.75"2.75"1.50"397 1245/-222 1642/-
222 Blocking
2 - Stud wall - SPF 3.50"3.50"2.28"950 2447 3397 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)7' 3" o/c
Bottom Edge (Lu)7' 3" o/c
Dead Floor Live
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments
0 - Self Weight (PLF)0 to 7' 2 3/4"N/A 6.4 --
1 - Uniform (PSF)0 to 7' 2 3/4" (Front)12'15.0 40.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
1st Floor Framing, Floor: Drop Beam ends
1 piece(s) 4 x 8 Douglas Fir-Larch No. 2
ForteWEB Software Operator Job Notes 1/17/2021 7:43:48 PM UTC
Chon Pieruccioni
Pieruccioni Engineering
(206) 949-7866
cpieru@hotmail.com
ForteWEB v3.1, Engine: V8.1.5.1, Data: V8.0.1.0
File Name: 15638 View Dr SE, Yelm
Page 17 / 17
SPECTRA Engineering Inc.Project:
Engineer:
Descrip:
Chon Pieruccioni
Entry Post Footing
Page # ___
1/14/2021
ASDIP Foundation 4.4.3.2 SPREAD FOOTING DESIGN www.asdipsoft.com
Footing Length (X-dir) ............
Footing Width (Z-dir) ..............
Footing Thickness ..................
Soil Cover ..............................
Column Length (X-dir) ...........
Column Width (Z-dir) ..............
Offset (X-dir) ...........................
Offset (Z-dir) ...........................
Base Plate (L x W) .....6.0 x 6.0 in
ft
ft
in
ft
in
in
in
in
OK
OK
OK
Dead Live RLive Snow Wind Seismic
Axial Force P .............
Moment about X Mx ..
Moment about Z Mz ..
Shear Force Vx .........
Shear Force Vz .........
kip
k-ft
k-ft
kip
kip
Gross Allow. Soil Pressure .......
Soil Pressure at Corner 1 .........
Soil Pressure at Corner 2 .........
Soil Pressure at Corner 3 .........
Soil Pressure at Corner 4 .........
Bearing Pressure Ratio .................
Ftg. Area in Contact with Soil ........
X-eccentricity / Ftg. Length ............
Z-eccentricity / Ftg. Width ..............
1.5
1.1
1.1
1.1
1.1
0.70
100.0
0.00
0.00
ksf
ksf
ksf
ksf
ksf
%
OK
OK
OK
- Moment Mx = 0.6 * 0.0 + 0.6 * 0.0 = 0.0 k-ft
- Shear Force Vz = 0.6 * 0.0 + 0.6 * 0.0 = 0.0 k-ft
Arm = 0.00 + 10.0 / 12 = 0.83 ft Moment = 0.0 * 0.83 = 0.0 k-ft
- Passive Force = 0.0 kip Arm = 0.33 ft Moment = 0.0 k-ft
- Overturning moment X-X = 0.0 + 0.0 = 0.0 k-ft
- Footing weight =0.6 * 2.00 * 2.00 * 10.0 / 12 * 0.15 = 0.3 kip
Arm =2.00 / 2 = 1.00 ft Moment = 0.3 * 1.00 = 0.3 k-ft
- Pedestal weight =0.6 * 6.0 / 12 * 6.0 / 12 * 0.0 * 0.15 = 0.0 kip
Arm =2.00 / 2 - 0.0 / 12 = 1.00 ft Moment = 0.0 * 1.00 = 0.0 k-ft
- Soil cover =0.6 * (2.00 * 2.00 - 6.0 / 12 * 6.0 / 12) * 0.0 * 110 = 0.0 kip
Arm =2.00 / 2 = 1.00 ft Moment = 0.0 * 1.00 = 0.0 k-ft
- Buoyancy =0.6 * 2.00 * 2.00 * 62 * (0.00 + 10.0 / 12 - 0.00) = -0.1 kip
Arm =2.00 / 2 = 1.00 ft Moment = 0.1 * 1.00 = -0.1 k-ft
- Axial force P = 0.6 * 1.6 + 0.6 * 0.0 = 1.0 k-ft
Arm =2.00 / 2 - 0.0 / 12 = 1.00 ft Moment = 1.0 * 1.00 = 1.0 k-ft
- Resisting moment X-X = 0.3 + 0.0 + 0.0 + 1.0 + -0.1 = 1.1 k-ft
- Overturning safety factor X-X ==1.1
0.0 = 11.35 > 1.50 OK
1 of 7
SPECTRA Engineering Inc.Project:
Engineer:
Descrip:
Chon Pieruccioni
Entry Post Footing
Page # ___
1/14/2021
ASDIP Foundation 4.4.3.2 SPREAD FOOTING DESIGN www.asdipsoft.com
- Moment Mz = 0.6 * 0.0 + 0.6 * 0.0 = 0.0 k-ft
- Shear Force Vx = 0.6 * 0.0 + 0.6 * 0.0 = 0.0 k-ft
Arm = 0.00 + 10.0 / 12 = 0.83 ft Moment = 0.0 * 0.83 = 0.0 k-ft
- Passive Force = 0.0 kip Arm = 0.33 ft Moment = 0.0 k-ft
- Overturning moment Z-Z = 0.0 + 0.0 = 0.0 k-ft
- Footing weight =0.6 * 2.00 * 2.00 * 10.0 / 12 * 0.15 = 0.3 kip
Arm =2.00 / 2 = 1.00 ft Moment = 0.3 * 1.00 = 0.3 k-ft
- Pedestal weight =0.6 * 6.0 / 12 * 6.0 / 12 * 0.0 * 0.15 = 0.0 kip
Arm =2.00 / 2 - 0.0 / 12 = 1.00 ft Moment = 0.0 * 1.00 = 0.0 k-ft
- Soil cover =0.6 * (2.00 * 2.00 - 6.0 / 12 * 6.0 / 12) * 0.0 * 110 = 0.0 kip
Arm =2.00 / 2 = 1.00 ft Moment = 0.0 * 1.00 = 0.0 k-ft
- Buoyancy =0.6 * 2.00 * 2.00 * 62 * (0.00 + 10.0 / 12 - 0.00) = -0.1 kip
Arm =2.00 / 2 = 1.00 ft Moment = 0.1 * 1.00 = -0.1 k-ft
- Axial force P = 0.6 * 1.6 + 0.6 * 0.0 = 1.0 k-ft
Arm =2.00 / 2 - 0.0 / 12 = 1.00 ft Moment = 1.0 * 1.00 = 1.0 k-ft
- Resisting moment Z-Z = 0.3 + 0.0 + 0.0 + 1.0 + -0.1 = 1.1 k-ft
- Overturning safety factor Z-Z ==1.1
0.0 = 11.35 > 1.50 OK
Overturning moment X-X = 0.0 + 0.0 = 0.0 k-ft
Resisting moment X-X = 0.5 + 0.0 + 0.0 + -0.2 + 3.9 = 4.2 k-ft
Overturning moment Z-Z = 0.0 + 0.0 = 0.0 k-ft
Resisting moment Z-Z = 0.5 + 0.0 + 0.0 + -0.2 + 3.9 = 4.2 k-ft
Resisting force =0.5 + 0.0 + 0.0 - 0.2 + 3.9 = 4.2 kip
X-coordinate of resultant from maximum bearing corner:
Xp ==4.2 - 0.0
4.2 = 1.00 ft
Z-coordinate of resultant from maximum bearing corner:
Zp ==4.2 - 0.0
4.2 = 1.00 ft
X-ecc =2.00 / 2 - 1.00 = 0.00 ft
Z-ecc =2.00 / 2 - 1.00 = 0.00 ft
Area =2.00 * 2.00 = 4.0 ft²
Sx =2.00 * 2.00² / 6 = 1.3 ft³
Sz =2.00 * 2.00² / 6 = 1.3 ft³
- Footing is in full bearing. Soil pressures are as follows:
P1 =4.2 * (1 / 4.0 + 0.00 / 1.3 + 0.00 / 1.3) = 1.05 ksf
P2 =4.2 * (1 / 4.0 - 0.00 / 1.3 + 0.00 / 1.3) = 1.05 ksf
P3 =4.2 * (1 / 4.0 - 0.00 / 1.3 - 0.00 / 1.3) = 1.05 ksf
P4 =4.2 * (1 / 4.0 + 0.00 / 1.3 - 0.00 / 1.3) = 1.05 ksf 2 of 7
SPECTRA Engineering Inc.Project:
Engineer:
Descrip:
Chon Pieruccioni
Entry Post Footing
Page # ___
1/14/2021
ASDIP Foundation 4.4.3.2 SPREAD FOOTING DESIGN www.asdipsoft.com
Internal friction angle = 28.0 deg Active coefficient ka = 0.36
Passive coefficient 1 / 0.36 = 2.77
Pressure at mid-depth =2.77 * 110 * (0.00 + 10.0 / 12 / 2) = 0.13 ksf
X-Passive force =0.13 * 10.0 / 12 * 2.00 = 0.2 kip
Z-Passive force =0.13 * 10.0 / 12 * 2.00 = 0.2 kip
Friction force =Max (0, 1.1 * 0.35) = 0.4 kip
- Sliding safety factor X-X ==1.00 * 0.2 + 1.00 * 0.4
0.0 = 6.09 > 1.50 OK
- Sliding safety factor Z-Z ==1.00 * 0.2 + 1.00 * 0.4
0.0 = 6.09 > 1.50 OK
- Uplift safety factor ==0.0 + 0.3 + 0.0 - 0.1
0.0 = 99.99 > 1.00 OK
Concrete f'c =2.5 ksi Steel fy =40.0 ksi Soil density =110 pcf
d Top X-dir =10.0 - 2.0 - 0.8 / 2 = 7.6 in
d Top Z-dir =10.0 - 2.0 - 0.8 - 0.8 / 2 = 6.9 in
d Bot X-dir =10.0 - 3.0 - 0.8 / 2 = 6.6 in
d Bot Z-dir =10.0 - 3.0 - 0.8 - 0.8 / 2 = 5.9 in
ϕVcx =2 * 0.75 * √(2500) * 2.0 * 12 * 6.6 / 1000 = 11.9 kip
ϕVcz =2 * 0.75 * √(2500) * 2.0 * 12 * 5.9 / 1000 = 10.6 kip
ACI Eq. (22.5.5.1)
- Shear forces calculated as the volume of the bearing pressures under the effective areas:
One-way shear Vux (- Side) = 0.6 kip
One-way shear Vux (+ Side) = 0.6 kip
One-way shear Vuz (- Side) = 0.6 kip
One-way shear Vuz (+ Side) = 0.6 kip
< 11.9 kip OK
< 11.9 kip OK
< 10.6 kip OK
< 10.6 kip OK
3 of 7
SPECTRA Engineering Inc.Project:
Engineer:
Descrip:
Chon Pieruccioni
Entry Post Footing
Page # ___
1/14/2021
ASDIP Foundation 4.4.3.2 SPREAD FOOTING DESIGN www.asdipsoft.com
Plain ϕMnx =5 * 0.60 * √(2500) * 2.00 * 10.0² / 6 / 1000 = 5.0 k-ft
Plain ϕMnz =5 * 0.60 * √(2500) * 2.00 * 10.0² / 6 / 1000 = 5.0 k-ft
ACI Eq. (14.5.2.1a)
Use Plain Concrete Flexural Strength at Top
- Top moments calculated as the overburden minus the bearing pressures times the lever arm:
Top moment -Mux (- Side) = 0.0 k-ft
Top moment -Mux (+ Side) = 0.0 k-ft
Top moment -Muz (- Side) = 0.0 k-ft
Top moment -Muz (+ Side) = 0.0 k-ft
< 5.0 k-ft OK
< 5.0 k-ft OK
< 5.0 k-ft OK
< 5.0 k-ft OK
Use Plain Concrete Flexural Strength at Bottom
- Bottom moments calculated as the bearing minus the overburden pressures times the lever arm:
Bottom moment Mux (- Side) = 0.8 k-ft
Bottom moment Mux (+ Side) = 0.8 k-ft
Bottom moment Muz (- Side) = 0.8 k-ft
Bottom moment Muz (+ Side) = 0.8 k-ft
< 5.0 k-ft OK
< 5.0 k-ft OK
< 5.0 k-ft OK
< 5.0 k-ft OK
ratio = 0.16
ratio = 0.16
ratio = 0.16
ratio = 0.16
4 of 7
SPECTRA Engineering Inc.Project:
Engineer:
Descrip:
Chon Pieruccioni
Entry Post Footing
Page # ___
1/14/2021
ASDIP Foundation 4.4.3.2 SPREAD FOOTING DESIGN www.asdipsoft.com
Area 6.0 * 6.0 = 36.0 in²
Sx =6.0 * 6.0² / 6 = 36.0 in³
Sz =6.0 * 6.0² / 6 = 36.0 in³
Bearing 5.8 / 36.0 + 0.0 * 12 / 36.0 + 0.0 * 12 / 36.0 = 0.2 ksi
Min edge =
Min edge = Min (2.00 * 12 / 2 - 0.0 - 6.0 / 2, 2.00 * 12 / 2 - 0.0 - 6.0 / 2 = 9.0 in
Area
A2 = Min [2.00 * 12 * 2.0 * 12, (6.0 + 2 * 9.0) * (6.0 + 2 * 9.0)] = 576.0 in²
ACI R22.8.3.2
Footing 0.65 * 0.85 * 2.5 * Min [2, √(576.0 / 36.0)] = 2.8 ksi
Footing 0.65 * 0.00 * 60.0 / 36.0 = 0.0 ksi ACI 22.8.3.2
Footing bearing 2.8 + 0.0 = 2.8 ksi > 0.2 psi OK
5 of 7
SPECTRA Engineering Inc.Project:
Engineer:
Descrip:
Chon Pieruccioni
Entry Post Footing
Page # ___
1/14/2021
ASDIP Foundation 4.4.3.2 SPREAD FOOTING DESIGN www.asdipsoft.com
X-Edge =2.00 * 12 / 2 - 0.0 - 6.0 / 2 = 9.0 in αsx = 10
Z-Edge =2.00 * 12 / 2 - 0.0 - 6.0 / 2 = 9.0 in αsz = 10
αs =10 + 10 = 20 Col type = Corner β =6.0 / 6.0 = 1.00 ACI 22.6.5.2
Perimeter
bo = 10 / 10 * (6.0 + 6.3 / 2 + 9.0) + 10 / 10 * (6.0 + 6.3 / 2 + 9.0) = 36.3 in
ACI 22.6.4.2
Area (6.0 + 6.3 / 2 + 9.0) * (6.0 + 6.3 / 2 + 9.0) = 328.5 in²
ϕVc =
ϕVc = 0.75 * Min (2 + 4 / 1.00, 20 * 6.3 / 36.3 + 2, 4) * √(2500) = 150.0 psi
ACI 22.6.5.2
Punching force
F = 5.8 + 0.15 * 328.5 / 144 - 1.6 = 4.5 kip
b1 =6.0 + 6.3 / 2 + 9.0 = 18.1 in b2 =6.0 + 6.3 / 2 + 9.0 = 18.1 in
γvx factor == 1 -1
1 + (2/3) √(18.1 / 18.1)= 0.40
γvz factor =
ACI Eq. (8.4.4.2.2)
ACI Eq. (8.4.2.3.2)= 1 -1
1 + (2/3) √(18.1 / 18.1)= 0.40
X2z =18.1² / 2 / (18.1 + 18.1) = 4.5 in X2x =4.5 in
Jcz =
Jcz = 18.1 * 6.3³ / 12 + 18.1³ * 6.3 / 12 + 18.1 * 6.3 * (18.1 / 2 * 4.5)² + 18.1 * 6.3 * 4.5² = 8122 in⁴
Jcx =
Jcz = 18.1 * 6.3³ / 12 + 18.1³ * 6.3 / 12 + 18.1 * 6.3 * (18.1 / 2 * 4.5)² + 18.1 * 6.3 * 4.5² = 8122 in⁴
ACI R8.4.4.2.3
ACI R8.4.4.2.3
Stress due to P =4.5 / (36.3 * 6.3) * 1000 = 20.0 psi
Stress due to Mx =0.40 * 0.0 * 12 * 4.5 / 8122 * 1000 = 0.0 psi
Stress due to Mz =0.40 * 0.0 * 12 * 4.5 / 8122 * 1000 = 0.0 psi
Punching stress =20.0 + 0.0 + 0.0 = 20.0 psi < 150.0 psi OK
6 of 7
SPECTRA Engineering Inc.Project:
Engineer:
Descrip:
Chon Pieruccioni
Entry Post Footing
Page # ___
1/14/2021
ASDIP Foundation 4.4.3.2 SPREAD FOOTING DESIGN www.asdipsoft.com
Concrete Design ..................
Load Combinations ..............
ACI 318-14
ASCE 7-10
7 of 7
SPECTRA Engineering Inc.Project:
Engineer:
Descrip:
Chon Pieruccioni
Isolated Footing
Page # ___
1/14/2021
ASDIP Foundation 4.4.3.2 SPREAD FOOTING DESIGN www.asdipsoft.com
Footing Length (X-dir) ............
Footing Width (Z-dir) ..............
Footing Thickness ..................
Soil Cover ..............................
Column Length (X-dir) ...........
Column Width (Z-dir) ..............
Offset (X-dir) ...........................
Offset (Z-dir) ...........................
Base Plate (L x W) .....6.0 x 6.0 in
ft
ft
in
ft
in
in
in
in
OK
OK
OK
Dead Live RLive Snow Wind Seismic
Axial Force P .............
Moment about X Mx ..
Moment about Z Mz ..
Shear Force Vx .........
Shear Force Vz .........
kip
k-ft
k-ft
kip
kip
Gross Allow. Soil Pressure .......
Soil Pressure at Corner 1 .........
Soil Pressure at Corner 2 .........
Soil Pressure at Corner 3 .........
Soil Pressure at Corner 4 .........
Bearing Pressure Ratio .................
Ftg. Area in Contact with Soil ........
X-eccentricity / Ftg. Length ............
Z-eccentricity / Ftg. Width ..............
1.5
1.4
1.4
1.4
1.4
0.93
100.0
0.00
0.00
ksf
ksf
ksf
ksf
ksf
%
OK
OK
OK
- Moment Mx = 0.6 * 0.0 + 0.6 * 0.0 = 0.0 k-ft
- Shear Force Vz = 0.6 * 0.0 + 0.6 * 0.0 = 0.0 k-ft
Arm = 0.00 + 10.0 / 12 = 0.83 ft Moment = 0.0 * 0.83 = 0.0 k-ft
- Passive Force = 0.0 kip Arm = 0.33 ft Moment = 0.0 k-ft
- Overturning moment X-X = 0.0 + 0.0 = 0.0 k-ft
- Footing weight =0.6 * 2.00 * 2.00 * 10.0 / 12 * 0.15 = 0.3 kip
Arm =2.00 / 2 = 1.00 ft Moment = 0.3 * 1.00 = 0.3 k-ft
- Pedestal weight =0.6 * 6.0 / 12 * 6.0 / 12 * 0.0 * 0.15 = 0.0 kip
Arm =2.00 / 2 - 0.0 / 12 = 1.00 ft Moment = 0.0 * 1.00 = 0.0 k-ft
- Soil cover =0.6 * (2.00 * 2.00 - 6.0 / 12 * 6.0 / 12) * 0.0 * 110 = 0.0 kip
Arm =2.00 / 2 = 1.00 ft Moment = 0.0 * 1.00 = 0.0 k-ft
- Buoyancy =0.6 * 2.00 * 2.00 * 62 * (0.00 + 10.0 / 12 - 0.00) = -0.1 kip
Arm =2.00 / 2 = 1.00 ft Moment = 0.1 * 1.00 = -0.1 k-ft
- Axial force P = 0.6 * 1.5 + 0.6 * 0.0 = 0.9 k-ft
Arm =2.00 / 2 - 0.0 / 12 = 1.00 ft Moment = 0.9 * 1.00 = 0.9 k-ft
- Resisting moment X-X = 0.3 + 0.0 + 0.0 + 0.9 + -0.1 = 1.1 k-ft
- Overturning safety factor X-X ==1.1
0.0 = 10.75 > 1.50 OK
1 of 7
SPECTRA Engineering Inc.Project:
Engineer:
Descrip:
Chon Pieruccioni
Isolated Footing
Page # ___
1/14/2021
ASDIP Foundation 4.4.3.2 SPREAD FOOTING DESIGN www.asdipsoft.com
- Moment Mz = 0.6 * 0.0 + 0.6 * 0.0 = 0.0 k-ft
- Shear Force Vx = 0.6 * 0.0 + 0.6 * 0.0 = 0.0 k-ft
Arm = 0.00 + 10.0 / 12 = 0.83 ft Moment = 0.0 * 0.83 = 0.0 k-ft
- Passive Force = 0.0 kip Arm = 0.33 ft Moment = 0.0 k-ft
- Overturning moment Z-Z = 0.0 + 0.0 = 0.0 k-ft
- Footing weight =0.6 * 2.00 * 2.00 * 10.0 / 12 * 0.15 = 0.3 kip
Arm =2.00 / 2 = 1.00 ft Moment = 0.3 * 1.00 = 0.3 k-ft
- Pedestal weight =0.6 * 6.0 / 12 * 6.0 / 12 * 0.0 * 0.15 = 0.0 kip
Arm =2.00 / 2 - 0.0 / 12 = 1.00 ft Moment = 0.0 * 1.00 = 0.0 k-ft
- Soil cover =0.6 * (2.00 * 2.00 - 6.0 / 12 * 6.0 / 12) * 0.0 * 110 = 0.0 kip
Arm =2.00 / 2 = 1.00 ft Moment = 0.0 * 1.00 = 0.0 k-ft
- Buoyancy =0.6 * 2.00 * 2.00 * 62 * (0.00 + 10.0 / 12 - 0.00) = -0.1 kip
Arm =2.00 / 2 = 1.00 ft Moment = 0.1 * 1.00 = -0.1 k-ft
- Axial force P = 0.6 * 1.5 + 0.6 * 0.0 = 0.9 k-ft
Arm =2.00 / 2 - 0.0 / 12 = 1.00 ft Moment = 0.9 * 1.00 = 0.9 k-ft
- Resisting moment Z-Z = 0.3 + 0.0 + 0.0 + 0.9 + -0.1 = 1.1 k-ft
- Overturning safety factor Z-Z ==1.1
0.0 = 10.75 > 1.50 OK
Overturning moment X-X = 0.0 + 0.0 = 0.0 k-ft
Resisting moment X-X = 0.5 + 0.0 + 0.0 + -0.2 + 5.3 = 5.6 k-ft
Overturning moment Z-Z = 0.0 + 0.0 = 0.0 k-ft
Resisting moment Z-Z = 0.5 + 0.0 + 0.0 + -0.2 + 5.3 = 5.6 k-ft
Resisting force =0.5 + 0.0 + 0.0 - 0.2 + 5.3 = 5.6 kip
X-coordinate of resultant from maximum bearing corner:
Xp ==5.6 - 0.0
5.6 = 1.00 ft
Z-coordinate of resultant from maximum bearing corner:
Zp ==5.6 - 0.0
5.6 = 1.00 ft
X-ecc =2.00 / 2 - 1.00 = 0.00 ft
Z-ecc =2.00 / 2 - 1.00 = 0.00 ft
Area =2.00 * 2.00 = 4.0 ft²
Sx =2.00 * 2.00² / 6 = 1.3 ft³
Sz =2.00 * 2.00² / 6 = 1.3 ft³
- Footing is in full bearing. Soil pressures are as follows:
P1 =5.6 * (1 / 4.0 + 0.00 / 1.3 + 0.00 / 1.3) = 1.40 ksf
P2 =5.6 * (1 / 4.0 - 0.00 / 1.3 + 0.00 / 1.3) = 1.40 ksf
P3 =5.6 * (1 / 4.0 - 0.00 / 1.3 - 0.00 / 1.3) = 1.40 ksf
P4 =5.6 * (1 / 4.0 + 0.00 / 1.3 - 0.00 / 1.3) = 1.40 ksf 2 of 7
SPECTRA Engineering Inc.Project:
Engineer:
Descrip:
Chon Pieruccioni
Isolated Footing
Page # ___
1/14/2021
ASDIP Foundation 4.4.3.2 SPREAD FOOTING DESIGN www.asdipsoft.com
Internal friction angle = 28.0 deg Active coefficient ka = 0.36
Passive coefficient 1 / 0.36 = 2.77
Pressure at mid-depth =2.77 * 110 * (0.00 + 10.0 / 12 / 2) = 0.13 ksf
X-Passive force =0.13 * 10.0 / 12 * 2.00 = 0.2 kip
Z-Passive force =0.13 * 10.0 / 12 * 2.00 = 0.2 kip
Friction force =Max (0, 1.1 * 0.35) = 0.4 kip
- Sliding safety factor X-X ==1.00 * 0.2 + 1.00 * 0.4
0.0 = 5.88 > 1.50 OK
- Sliding safety factor Z-Z ==1.00 * 0.2 + 1.00 * 0.4
0.0 = 5.88 > 1.50 OK
- Uplift safety factor ==0.0 + 0.3 + 0.0 - 0.1
0.0 = 99.99 > 1.00 OK
Concrete f'c =2.5 ksi Steel fy =40.0 ksi Soil density =110 pcf
d Top X-dir =10.0 - 2.0 - 0.8 / 2 = 7.6 in
d Top Z-dir =10.0 - 2.0 - 0.8 - 0.8 / 2 = 6.9 in
d Bot X-dir =10.0 - 3.0 - 0.8 / 2 = 6.6 in
d Bot Z-dir =10.0 - 3.0 - 0.8 - 0.8 / 2 = 5.9 in
ϕVcx =2 * 0.75 * √(2500) * 2.0 * 12 * 6.6 / 1000 = 11.9 kip
ϕVcz =2 * 0.75 * √(2500) * 2.0 * 12 * 5.9 / 1000 = 10.6 kip
ACI Eq. (22.5.5.1)
- Shear forces calculated as the volume of the bearing pressures under the effective areas:
One-way shear Vux (- Side) = 0.9 kip
One-way shear Vux (+ Side) = 0.9 kip
One-way shear Vuz (- Side) = 0.9 kip
One-way shear Vuz (+ Side) = 0.9 kip
< 11.9 kip OK
< 11.9 kip OK
< 10.6 kip OK
< 10.6 kip OK
3 of 7
SPECTRA Engineering Inc.Project:
Engineer:
Descrip:
Chon Pieruccioni
Isolated Footing
Page # ___
1/14/2021
ASDIP Foundation 4.4.3.2 SPREAD FOOTING DESIGN www.asdipsoft.com
Plain ϕMnx =5 * 0.60 * √(2500) * 2.00 * 10.0² / 6 / 1000 = 5.0 k-ft
Plain ϕMnz =5 * 0.60 * √(2500) * 2.00 * 10.0² / 6 / 1000 = 5.0 k-ft
ACI Eq. (14.5.2.1a)
Use Plain Concrete Flexural Strength at Top
- Top moments calculated as the overburden minus the bearing pressures times the lever arm:
Top moment -Mux (- Side) = 0.0 k-ft
Top moment -Mux (+ Side) = 0.0 k-ft
Top moment -Muz (- Side) = 0.0 k-ft
Top moment -Muz (+ Side) = 0.0 k-ft
< 5.0 k-ft OK
< 5.0 k-ft OK
< 5.0 k-ft OK
< 5.0 k-ft OK
Use Plain Concrete Flexural Strength at Bottom
- Bottom moments calculated as the bearing minus the overburden pressures times the lever arm:
Bottom moment Mux (- Side) = 1.1 k-ft
Bottom moment Mux (+ Side) = 1.1 k-ft
Bottom moment Muz (- Side) = 1.1 k-ft
Bottom moment Muz (+ Side) = 1.1 k-ft
< 5.0 k-ft OK
< 5.0 k-ft OK
< 5.0 k-ft OK
< 5.0 k-ft OK
ratio = 0.22
ratio = 0.22
ratio = 0.22
ratio = 0.22
4 of 7
SPECTRA Engineering Inc.Project:
Engineer:
Descrip:
Chon Pieruccioni
Isolated Footing
Page # ___
1/14/2021
ASDIP Foundation 4.4.3.2 SPREAD FOOTING DESIGN www.asdipsoft.com
Area 6.0 * 6.0 = 36.0 in²
Sx =6.0 * 6.0² / 6 = 36.0 in³
Sz =6.0 * 6.0² / 6 = 36.0 in³
Bearing 7.9 / 36.0 + 0.0 * 12 / 36.0 + 0.0 * 12 / 36.0 = 0.2 ksi
Min edge =
Min edge = Min (2.00 * 12 / 2 - 0.0 - 6.0 / 2, 2.00 * 12 / 2 - 0.0 - 6.0 / 2 = 9.0 in
Area
A2 = Min [2.00 * 12 * 2.0 * 12, (6.0 + 2 * 9.0) * (6.0 + 2 * 9.0)] = 576.0 in²
ACI R22.8.3.2
Footing 0.65 * 0.85 * 2.5 * Min [2, √(576.0 / 36.0)] = 2.8 ksi
Footing 0.65 * 0.00 * 60.0 / 36.0 = 0.0 ksi ACI 22.8.3.2
Footing bearing 2.8 + 0.0 = 2.8 ksi > 0.2 psi OK
5 of 7
SPECTRA Engineering Inc.Project:
Engineer:
Descrip:
Chon Pieruccioni
Isolated Footing
Page # ___
1/14/2021
ASDIP Foundation 4.4.3.2 SPREAD FOOTING DESIGN www.asdipsoft.com
X-Edge =2.00 * 12 / 2 - 0.0 - 6.0 / 2 = 9.0 in αsx = 10
Z-Edge =2.00 * 12 / 2 - 0.0 - 6.0 / 2 = 9.0 in αsz = 10
αs =10 + 10 = 20 Col type = Corner β =6.0 / 6.0 = 1.00 ACI 22.6.5.2
Perimeter
bo = 10 / 10 * (6.0 + 6.3 / 2 + 9.0) + 10 / 10 * (6.0 + 6.3 / 2 + 9.0) = 36.3 in
ACI 22.6.4.2
Area (6.0 + 6.3 / 2 + 9.0) * (6.0 + 6.3 / 2 + 9.0) = 328.5 in²
ϕVc =
ϕVc = 0.75 * Min (2 + 4 / 1.00, 20 * 6.3 / 36.3 + 2, 4) * √(2500) = 150.0 psi
ACI 22.6.5.2
Punching force
F = 7.9 + 0.15 * 328.5 / 144 - 2.1 = 6.1 kip
b1 =6.0 + 6.3 / 2 + 9.0 = 18.1 in b2 =6.0 + 6.3 / 2 + 9.0 = 18.1 in
γvx factor == 1 -1
1 + (2/3) √(18.1 / 18.1)= 0.40
γvz factor =
ACI Eq. (8.4.4.2.2)
ACI Eq. (8.4.2.3.2)= 1 -1
1 + (2/3) √(18.1 / 18.1)= 0.40
X2z =18.1² / 2 / (18.1 + 18.1) = 4.5 in X2x =4.5 in
Jcz =
Jcz = 18.1 * 6.3³ / 12 + 18.1³ * 6.3 / 12 + 18.1 * 6.3 * (18.1 / 2 * 4.5)² + 18.1 * 6.3 * 4.5² = 8122 in⁴
Jcx =
Jcz = 18.1 * 6.3³ / 12 + 18.1³ * 6.3 / 12 + 18.1 * 6.3 * (18.1 / 2 * 4.5)² + 18.1 * 6.3 * 4.5² = 8122 in⁴
ACI R8.4.4.2.3
ACI R8.4.4.2.3
Stress due to P =6.1 / (36.3 * 6.3) * 1000 = 26.8 psi
Stress due to Mx =0.40 * 0.0 * 12 * 4.5 / 8122 * 1000 = 0.0 psi
Stress due to Mz =0.40 * 0.0 * 12 * 4.5 / 8122 * 1000 = 0.0 psi
Punching stress =26.8 + 0.0 + 0.0 = 26.8 psi < 150.0 psi OK
6 of 7
SPECTRA Engineering Inc.Project:
Engineer:
Descrip:
Chon Pieruccioni
Isolated Footing
Page # ___
1/14/2021
ASDIP Foundation 4.4.3.2 SPREAD FOOTING DESIGN www.asdipsoft.com
Concrete Design ..................
Load Combinations ..............
ACI 318-14
ASCE 7-10
7 of 7
SPECTRA Engineering Inc.Project:
Engineer:
Descrip:
Chon Pieruccioni
Typical Crawl Footing
Page # ___
1/14/2021
ASDIP Foundation 4.4.3.2 SPREAD FOOTING DESIGN www.asdipsoft.com
Footing Length (X-dir) ............
Footing Width (Z-dir) ..............
Footing Thickness ..................
Soil Cover ..............................
Column Length (X-dir) ...........
Column Width (Z-dir) ..............
Offset (X-dir) ...........................
Offset (Z-dir) ...........................
Base Plate (L x W) .....6.0 x 6.0 in
ft
ft
in
ft
in
in
in
in
OK
OK
OK
Dead Live RLive Snow Wind Seismic
Axial Force P .............
Moment about X Mx ..
Moment about Z Mz ..
Shear Force Vx .........
Shear Force Vz .........
kip
k-ft
k-ft
kip
kip
Gross Allow. Soil Pressure .......
Soil Pressure at Corner 1 .........
Soil Pressure at Corner 2 .........
Soil Pressure at Corner 3 .........
Soil Pressure at Corner 4 .........
Bearing Pressure Ratio .................
Ftg. Area in Contact with Soil ........
X-eccentricity / Ftg. Length ............
Z-eccentricity / Ftg. Width ..............
1.5
1.2
1.2
1.2
1.2
0.81
100.0
0.00
0.00
ksf
ksf
ksf
ksf
ksf
%
OK
OK
OK
- Moment Mx = 0.6 * 0.0 + 0.6 * 0.0 = 0.0 k-ft
- Shear Force Vz = 0.6 * 0.0 + 0.6 * 0.0 = 0.0 k-ft
Arm = 0.00 + 10.0 / 12 = 0.83 ft Moment = 0.0 * 0.83 = 0.0 k-ft
- Passive Force = 0.0 kip Arm = 0.33 ft Moment = 0.0 k-ft
- Overturning moment X-X = 0.0 + 0.0 = 0.0 k-ft
- Footing weight =0.6 * 1.75 * 1.75 * 10.0 / 12 * 0.15 = 0.2 kip
Arm =1.75 / 2 = 0.88 ft Moment = 0.2 * 0.88 = 0.2 k-ft
- Pedestal weight =0.6 * 6.0 / 12 * 6.0 / 12 * 0.0 * 0.15 = 0.0 kip
Arm =1.75 / 2 - 0.0 / 12 = 0.88 ft Moment = 0.0 * 0.88 = 0.0 k-ft
- Soil cover =0.6 * (1.75 * 1.75 - 6.0 / 12 * 6.0 / 12) * 0.0 * 110 = 0.0 kip
Arm =1.75 / 2 = 0.88 ft Moment = 0.0 * 0.88 = 0.0 k-ft
- Buoyancy =0.6 * 1.75 * 1.75 * 62 * (0.00 + 10.0 / 12 - 0.00) = -0.1 kip
Arm =1.75 / 2 = 0.88 ft Moment = 0.1 * 0.88 = -0.1 k-ft
- Axial force P = 0.6 * 1.0 + 0.6 * 0.0 = 0.6 k-ft
Arm =1.75 / 2 - 0.0 / 12 = 0.88 ft Moment = 0.6 * 0.88 = 0.5 k-ft
- Resisting moment X-X = 0.2 + 0.0 + 0.0 + 0.5 + -0.1 = 0.6 k-ft
- Overturning safety factor X-X ==0.6
0.0 = 6.42 > 1.50 OK
1 of 7
SPECTRA Engineering Inc.Project:
Engineer:
Descrip:
Chon Pieruccioni
Typical Crawl Footing
Page # ___
1/14/2021
ASDIP Foundation 4.4.3.2 SPREAD FOOTING DESIGN www.asdipsoft.com
- Moment Mz = 0.6 * 0.0 + 0.6 * 0.0 = 0.0 k-ft
- Shear Force Vx = 0.6 * 0.0 + 0.6 * 0.0 = 0.0 k-ft
Arm = 0.00 + 10.0 / 12 = 0.83 ft Moment = 0.0 * 0.83 = 0.0 k-ft
- Passive Force = 0.0 kip Arm = 0.33 ft Moment = 0.0 k-ft
- Overturning moment Z-Z = 0.0 + 0.0 = 0.0 k-ft
- Footing weight =0.6 * 1.75 * 1.75 * 10.0 / 12 * 0.15 = 0.2 kip
Arm =1.75 / 2 = 0.88 ft Moment = 0.2 * 0.88 = 0.2 k-ft
- Pedestal weight =0.6 * 6.0 / 12 * 6.0 / 12 * 0.0 * 0.15 = 0.0 kip
Arm =1.75 / 2 - 0.0 / 12 = 0.88 ft Moment = 0.0 * 0.88 = 0.0 k-ft
- Soil cover =0.6 * (1.75 * 1.75 - 6.0 / 12 * 6.0 / 12) * 0.0 * 110 = 0.0 kip
Arm =1.75 / 2 = 0.88 ft Moment = 0.0 * 0.88 = 0.0 k-ft
- Buoyancy =0.6 * 1.75 * 1.75 * 62 * (0.00 + 10.0 / 12 - 0.00) = -0.1 kip
Arm =1.75 / 2 = 0.88 ft Moment = 0.1 * 0.88 = -0.1 k-ft
- Axial force P = 0.6 * 1.0 + 0.6 * 0.0 = 0.6 k-ft
Arm =1.75 / 2 - 0.0 / 12 = 0.88 ft Moment = 0.6 * 0.88 = 0.5 k-ft
- Resisting moment Z-Z = 0.2 + 0.0 + 0.0 + 0.5 + -0.1 = 0.6 k-ft
- Overturning safety factor Z-Z ==0.6
0.0 = 6.42 > 1.50 OK
Overturning moment X-X = 0.0 + 0.0 = 0.0 k-ft
Resisting moment X-X = 0.3 + 0.0 + 0.0 + -0.1 + 3.1 = 3.3 k-ft
Overturning moment Z-Z = 0.0 + 0.0 = 0.0 k-ft
Resisting moment Z-Z = 0.3 + 0.0 + 0.0 + -0.1 + 3.1 = 3.3 k-ft
Resisting force =0.4 + 0.0 + 0.0 - 0.2 + 3.5 = 3.7 kip
X-coordinate of resultant from maximum bearing corner:
Xp ==3.3 - 0.0
3.7 = 0.88 ft
Z-coordinate of resultant from maximum bearing corner:
Zp ==3.3 - 0.0
3.7 = 0.88 ft
X-ecc =1.75 / 2 - 0.88 = 0.00 ft
Z-ecc =1.75 / 2 - 0.88 = 0.00 ft
Area =1.75 * 1.75 = 3.1 ft²
Sx =1.75 * 1.75² / 6 = 0.9 ft³
Sz =1.75 * 1.75² / 6 = 0.9 ft³
- Footing is in full bearing. Soil pressures are as follows:
P1 =3.7 * (1 / 3.1 + 0.00 / 0.9 + 0.00 / 0.9) = 1.22 ksf
P2 =3.7 * (1 / 3.1 - 0.00 / 0.9 + 0.00 / 0.9) = 1.22 ksf
P3 =3.7 * (1 / 3.1 - 0.00 / 0.9 - 0.00 / 0.9) = 1.22 ksf
P4 =3.7 * (1 / 3.1 + 0.00 / 0.9 - 0.00 / 0.9) = 1.22 ksf 2 of 7
SPECTRA Engineering Inc.Project:
Engineer:
Descrip:
Chon Pieruccioni
Typical Crawl Footing
Page # ___
1/14/2021
ASDIP Foundation 4.4.3.2 SPREAD FOOTING DESIGN www.asdipsoft.com
Internal friction angle = 28.0 deg Active coefficient ka = 0.36
Passive coefficient 1 / 0.36 = 2.77
Pressure at mid-depth =2.77 * 110 * (0.00 + 10.0 / 12 / 2) = 0.13 ksf
X-Passive force =0.13 * 10.0 / 12 * 1.75 = 0.2 kip
Z-Passive force =0.13 * 10.0 / 12 * 1.75 = 0.2 kip
Friction force =Max (0, 0.7 * 0.35) = 0.3 kip
- Sliding safety factor X-X ==1.00 * 0.2 + 1.00 * 0.3
0.0 = 4.42 > 1.50 OK
- Sliding safety factor Z-Z ==1.00 * 0.2 + 1.00 * 0.3
0.0 = 4.42 > 1.50 OK
- Uplift safety factor ==0.0 + 0.2 + 0.0 - 0.1
0.0 = 99.99 > 1.00 OK
Concrete f'c =2.5 ksi Steel fy =40.0 ksi Soil density =110 pcf
d Top X-dir =10.0 - 2.0 - 0.8 / 2 = 7.6 in
d Top Z-dir =10.0 - 2.0 - 0.8 - 0.8 / 2 = 6.9 in
d Bot X-dir =10.0 - 3.0 - 0.8 / 2 = 6.6 in
d Bot Z-dir =10.0 - 3.0 - 0.8 - 0.8 / 2 = 5.9 in
ϕVcx =2 * 0.75 * √(2500) * 1.8 * 12 * 6.6 / 1000 = 10.4 kip
ϕVcz =2 * 0.75 * √(2500) * 1.8 * 12 * 5.9 / 1000 = 9.3 kip
ACI Eq. (22.5.5.1)
- Shear forces calculated as the volume of the bearing pressures under the effective areas:
One-way shear Vux (- Side) = 0.3 kip
One-way shear Vux (+ Side) = 0.3 kip
One-way shear Vuz (- Side) = 0.3 kip
One-way shear Vuz (+ Side) = 0.3 kip
< 10.4 kip OK
< 10.4 kip OK
< 9.3 kip OK
< 9.3 kip OK
3 of 7
SPECTRA Engineering Inc.Project:
Engineer:
Descrip:
Chon Pieruccioni
Typical Crawl Footing
Page # ___
1/14/2021
ASDIP Foundation 4.4.3.2 SPREAD FOOTING DESIGN www.asdipsoft.com
Plain ϕMnx =5 * 0.60 * √(2500) * 1.75 * 10.0² / 6 / 1000 = 4.4 k-ft
Plain ϕMnz =5 * 0.60 * √(2500) * 1.75 * 10.0² / 6 / 1000 = 4.4 k-ft
ACI Eq. (14.5.2.1a)
Use Plain Concrete Flexural Strength at Top
- Top moments calculated as the overburden minus the bearing pressures times the lever arm:
Top moment -Mux (- Side) = 0.0 k-ft
Top moment -Mux (+ Side) = 0.0 k-ft
Top moment -Muz (- Side) = 0.0 k-ft
Top moment -Muz (+ Side) = 0.0 k-ft
< 4.4 k-ft OK
< 4.4 k-ft OK
< 4.4 k-ft OK
< 4.4 k-ft OK
Use Plain Concrete Flexural Strength at Bottom
- Bottom moments calculated as the bearing minus the overburden pressures times the lever arm:
Bottom moment Mux (- Side) = 0.6 k-ft
Bottom moment Mux (+ Side) = 0.6 k-ft
Bottom moment Muz (- Side) = 0.6 k-ft
Bottom moment Muz (+ Side) = 0.6 k-ft
< 4.4 k-ft OK
< 4.4 k-ft OK
< 4.4 k-ft OK
< 4.4 k-ft OK
ratio = 0.13
ratio = 0.13
ratio = 0.13
ratio = 0.13
4 of 7
SPECTRA Engineering Inc.Project:
Engineer:
Descrip:
Chon Pieruccioni
Typical Crawl Footing
Page # ___
1/14/2021
ASDIP Foundation 4.4.3.2 SPREAD FOOTING DESIGN www.asdipsoft.com
Area 6.0 * 6.0 = 36.0 in²
Sx =6.0 * 6.0² / 6 = 36.0 in³
Sz =6.0 * 6.0² / 6 = 36.0 in³
Bearing 5.2 / 36.0 + 0.0 * 12 / 36.0 + 0.0 * 12 / 36.0 = 0.1 ksi
Min edge =
Min edge = Min (1.75 * 12 / 2 - 0.0 - 6.0 / 2, 1.75 * 12 / 2 - 0.0 - 6.0 / 2 = 7.5 in
Area
A2 = Min [1.75 * 12 * 1.8 * 12, (6.0 + 2 * 7.5) * (6.0 + 2 * 7.5)] = 441.0 in²
ACI R22.8.3.2
Footing 0.65 * 0.85 * 2.5 * Min [2, √(441.0 / 36.0)] = 2.8 ksi
Footing 0.65 * 0.00 * 60.0 / 36.0 = 0.0 ksi ACI 22.8.3.2
Footing bearing 2.8 + 0.0 = 2.8 ksi > 0.1 psi OK
5 of 7
SPECTRA Engineering Inc.Project:
Engineer:
Descrip:
Chon Pieruccioni
Typical Crawl Footing
Page # ___
1/14/2021
ASDIP Foundation 4.4.3.2 SPREAD FOOTING DESIGN www.asdipsoft.com
X-Edge =1.75 * 12 / 2 - 0.0 - 6.0 / 2 = 7.5 in αsx = 10
Z-Edge =1.75 * 12 / 2 - 0.0 - 6.0 / 2 = 7.5 in αsz = 10
αs =10 + 10 = 20 Col type = Corner β =6.0 / 6.0 = 1.00 ACI 22.6.5.2
Perimeter
bo = 10 / 10 * (6.0 + 6.3 / 2 + 7.5) + 10 / 10 * (6.0 + 6.3 / 2 + 7.5) = 33.3 in
ACI 22.6.4.2
Area (6.0 + 6.3 / 2 + 7.5) * (6.0 + 6.3 / 2 + 7.5) = 276.4 in²
ϕVc =
ϕVc = 0.75 * Min (2 + 4 / 1.00, 20 * 6.3 / 33.3 + 2, 4) * √(2500) = 150.0 psi
ACI 22.6.5.2
Punching force
F = 5.2 + 0.15 * 276.4 / 144 - 1.9 = 3.6 kip
b1 =6.0 + 6.3 / 2 + 7.5 = 16.6 in b2 =6.0 + 6.3 / 2 + 7.5 = 16.6 in
γvx factor == 1 -1
1 + (2/3) √(16.6 / 16.6)= 0.40
γvz factor =
ACI Eq. (8.4.4.2.2)
ACI Eq. (8.4.2.3.2)= 1 -1
1 + (2/3) √(16.6 / 16.6)= 0.40
X2z =16.6² / 2 / (16.6 + 16.6) = 4.2 in X2x =4.2 in
Jcz =
Jcz = 16.6 * 6.3³ / 12 + 16.6³ * 6.3 / 12 + 16.6 * 6.3 * (16.6 / 2 * 4.2)² + 16.6 * 6.3 * 4.2² = 6321 in⁴
Jcx =
Jcz = 16.6 * 6.3³ / 12 + 16.6³ * 6.3 / 12 + 16.6 * 6.3 * (16.6 / 2 * 4.2)² + 16.6 * 6.3 * 4.2² = 6321 in⁴
ACI R8.4.4.2.3
ACI R8.4.4.2.3
Stress due to P =3.6 / (33.3 * 6.3) * 1000 = 17.5 psi
Stress due to Mx =0.40 * 0.0 * 12 * 4.2 / 6321 * 1000 = 0.0 psi
Stress due to Mz =0.40 * 0.0 * 12 * 4.2 / 6321 * 1000 = 0.0 psi
Punching stress =17.5 + 0.0 + 0.0 = 17.5 psi < 150.0 psi OK
6 of 7
SPECTRA Engineering Inc.Project:
Engineer:
Descrip:
Chon Pieruccioni
Typical Crawl Footing
Page # ___
1/14/2021
ASDIP Foundation 4.4.3.2 SPREAD FOOTING DESIGN www.asdipsoft.com
Concrete Design ..................
Load Combinations ..............
ACI 318-14
ASCE 7-10
7 of 7
c\ OOc� 4 `Jtl'ib4 t X,SP t�1]'c165�x 1tl>Z �� g` S ��
S ITZ �r
�ti,or C
t_ `srV'�a2•�k as�����U'�akx�Ho��� * C3�bb2 tM'�b2h�T��•C�12 t x3' 3���3� 1.,�
:Ro V\ ? ebb?k
o\n, ' ®.EI I�f Iv EN� ZA4 ZM' Accu ! ei twa 'ln*�y*T z•
lk,
f1 2� 2-�h nt�11S'l`"1 ( �`��cs? LaccOm�a3'
NIX
s_
�)zz N44zL-AS r)( 2��� yVr�oc�a 3��S 7jq
" 1 s Y
�'5�Ff
.c 1�n r \243 8 n` �l`1 Y� Es a+ 1 r c ac nvr ti c'
0
r\= 3� t����=3C'�?V.--.
4 _ s -�> NS4.
3wfl t %t,-1`3"1-
a7
7?z5=
�t�Qdl i ((1Vtf"
4
r= c4TAD
li kx mrtS
r
�2 �7 2 a-V�D Bei, UZ �n S2��SZ
5 s4- Lam= 9 -�54,s,w\4 = � 02cA.�-
�' Aj%nCr^.
L _ �Pkr-'IZL JK
Wo c- 6 Do c
a,u � 0 = %A` a3?„
H o �,�15 �� 3'd.s�t\1=•S' lJ.1d � �-'�Yv.klnSt r63,—i a i'=V� �
1ZN14, p,?l_s-1-2bri
All
6