2021.0070.BP0004 YMS Transition Permit Elec NRECLighting Summary LTG-SUM Interior Lighting Plans Included Exteriorlighitng is not in scope. Compliance forms do not require a password to use. Instructional and calculating cells are write- protected. Select method used in project. Applicant Information. Provide contact information for individual who can respond to inquiries about compliance form information provided. Include PROJ-SUM form (included in envelope forms workboo k) with lighting compliance forms. Permanently installed interior lighting fixtures in dwelling units comply with: To comply with C406.4, no less than 90% of the total in stalled interior lighting power shall comply with the required controls per C406.4. All C405.2.1 - C405.2.8 Lighting Controls Addition is combined with existing: For interior lighting projects, include new + existing-to-remain interior lighting fixture wattage in Proposed Lighting Wattage table in LTG-INT-BLD or LTG-INT-SPACE form. For exterior lighting projects, include new + existing-to-remain exterior lighting fixture wattage in Proposed Tradable and Proposed Non-Tradable Lighting Wattage tables in LTG-EXT form. Refer to Section C502.2.6 for additional requirements. Lighting systems in addition area comply with all applicable provisions as a stand alone new construction project Lighting systems in additionare combined with existing building lighting systems to demonstrate compliance Additional Efficiency Package Option C406.4 Enhanced Digital Lighting C405.2 Exception 5 Luminaire Level Lighting Controls (LLLC) Dwelling unit lighting complies with WSEC Residential provisions in lieu of WSEC Commercial provisions. Building Area Method Space-by-space Method Alteration the TI classroom areas. New classrooms will be provided with vacancy sensors and photocell for day light dimming. No Lighting Scope Exterior Lighting Plans Included Lighting Summary, cont. LTG-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Interior and Exterior Lighting Alterations Existing interior lighting systems in areas under-going a change in space use are upgraded to comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2). Lamp and/or ballast replacement only –existing total wattage not increased New wiring installed to serve added fixtures and/or fixtures relocated to new circuit(s) New or moved lighting panel Interior space is reconfigured - luminaires unchanged or relocated 50% or more of existing are replaced 50% or more replaced - Total lighting power of new + existing-to-remain fixtures shall comply with total LPA per Sections C405.4.2 and C405.5.2. Include new + existing-to-remain fixtures in Proposed Lighting Wattage table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form. Less than 50% replaced -Total lighting power of new + existing-to-remainfixtures shall not exceed the total lighting power prior to alteration. Include new + existing-to-remain fixtures in the Proposed Lighting Wattage table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form. 50% threshold applies to number of luminaires for interior spaces and parking garages, and total installed wattage for exterior luminaires. Less than 50% of existing are replaced New wiring or circuit -For interior lighting, provide required manual controls per C405.2.3, occupancy sensor controls per C405.2.1, daylight responsive con trols per C405.2.4 and application specific lighting controls per C405.2.5. For exterior lighting, provide required controls per C405.2.7. New or moved panel -Provide all applicable lighting controls as noted for New Wiringand automatic time switch controls per C405.2.2. Reconfigured interior space -Provide all required lighting controls that apply to a new interior space. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured Select all Lighting Power and Lighting Control elements that apply to the scope of the retrofit project. If project includes a combination of spaces where less than 50% of the existing fixtures are replaced in some spaces, and 50% or more of the fixtures are replaced in others, then provide separate lighting power compliance forms for the two retrofit conditions. Spaces undergoing the same type of retrofit may be combined into one lighting power compliance form. Refer to Section C503.6 for additional requirements. All alteration lighting controls shall be commissioned per C408.3. Identify interior spaces requiringLPD upgrade to the current Code in Proposed Lighting Wattage table in LTG-INT-BLD or LTG-INT-SPACE form. No changes are being made to the interior or exterior lighting systems and existing space uses and configuration are not changed. Lighting, Motor, and Electrical Permit Checklist, P g. 1 LTG-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Title: Southworth Elementary Temporary Date 1/29/2021 Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes LIGHTING CONTROLS Yes C405.2 Lighting controls, general For all lighting fixtures, indicate lighting control method on plans for spaces and lighting zone(s) served, or exception taken E-001 NA C405.2 Luminaire level lighting controls (LLLC) Indicate on plans all fixtures provided with LLLC in lieu of C405.2 lighting controls; provide description of control capabilities and performance parameters NA C405.1 Lighting in dwelling units For permanently installed lighting fixtures in dwelling units, indicate lighting control method on plans for spaces and lighting zone(s) served, or demonstrate compliance with high efficacy exception Yes C405.2.3 C405.2.1.1 C405.2.2.2 C405.2.4 C405.2.5 Manual controls Indicate on plans the method of manual lighting control (whether combined with occupancy sensor, automatic light reduction, daylight responsive or specific application controls), location of manual control device and area or specific application it serves E-001 Yes C405.2.2.1 C405.2.2.2 C405.2.3 Manual interior light reduction controls Indicate on plans which method of manual 50% lighting load reduction is provided, or whether lighting load is reduced via occupancy sensors or daylight responsive controls E-201,E-202 Indicate on plans the method of automatic shut-off control during unoccupied periods (occupancy sensor, time switch or digital timer switch) for all lighting zones; Indicate locations where automatic shutoff is provided by other methods (occupancy sensor or digital timer switch) or which time switch control exception applies Indicate on plans the spaces served by occupancy sensors;E-201,E-202,E-001 Indicate whether occupancy sensor controls are configured to be manual-on, automatic 50%-on, or serve a space eligible for automatic 100%-on per exception E-201,E-202,E-001 NA C405.2.1.2 Occupancy sensor controls - warehouses Indicate aisleways and open areas in warehouse spaces provided with occupancy sensor controls that reduce lighting power by 50% NA C405.2.2.1 Automatic time switch controls Indicate locations of override switches on plans and the lighting zone(s) served, include area sq. ft. N/A C405.2.6 Digital timer switch Indicate digital timer switch control includes: manual on/off, time delay, audible and visual indication of impending time-out Indicate primary and secondary sidelight daylight zone areas on plans, include sq. ft.;E-202 Indicate toplight daylight zone areas on plans, include sq. ft.;E-202 For small vertical fenestration assemblies (rough opening less than 10 percent of primary daylight zone) where daylight responsive controls are not required, provide fenestration area to daylight zone calculation(s) E-202 Indicate on plans lighting zone(s) served by daylight responsive controls;E-202 Identify sidelight and toplight daylight zones that are not provided with daylight sensing controls and the exception(s) that apply; N/A Indicate on plans the lighting load reduction method - continuous dimming, or stepped dimming that provides at least two even steps between 0%-100% of rated power; E-202 Indicate that daylight sensing controls are configured to completely shut off all controlled lights in the lighting zone E-202 NA C405.2.5 Additional controls - Specific application lighting controls Identify spaces and lighting fixtures on plans that require specific application lighting controls per this section Indicate on plans that display and accent lighting, and display case lighting are controlled independently from both general area lighting and other lighting applications within the same space; Indicate manual and automatic lighting control method Yes C405.2.4.2 C405.2.4.3 Daylight zones - Sidelight and toplight NA C405.2.5 - Items 1&2 Display and accent lighting Yes C405.2.4 Daylight responsive controls Yes C405.2.1 C405.2.1.1 Occupancy sensor controls NA C405.2.2 Method of automatic shut-off control The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Lighting, Motor, and Electrical Permit Checklist, P g. 2 LTG-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Title: Southworth Elementary Temporary Date 1/29/2021 Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes NA C405.2.5 - Item 3 Hotel/motel guest rooms Indicate method of automatic control - vacancy or c aptive key control of all installed luminaires and switched receptacles in guest room NA C405.2.5 - Item 4 Supplemental task lighting Indicate method and location of automatic shut-off vacancy control for supplemental task lighting, including under-shelf or under-cabinet lighting Indicate on plans eligible non-visual lighting applications, include sq. ft. area of each lighting control zone; Indicate on plans that non-visual lighting are controlled independently from both general area lighting and other lighting applications within the same space; Indicate method of manual lighting control and appl icable automatic lighting control Indicate on plans that lighting equipment for sale or demonstration are controlled independently from both general area lighting and other lighting applications within the same space; Indicate method of manual lighting control and appl icable automatic lighting control Identify on plans egress fixtures that function as both normal and emergency means of egress illumination;E-201,E-202 Provide calculation of lighting power density of total egress lighting; E-001 If total egress lighting power density is greater than 0.02 W/sq. ft., indicate on plans egress fixtures requiring automatic shut-off during unoccupied periods; Indicate method of automatic shut-off control E-001 Indicate on exterior lighting plans and fixture schedules the automatic lighting control method, control sequence, and locations served; For building facade and landscape lighting, indicate automatic controls shut off lighting as a function of dawn/dusk and fixed opening/closing time; For all other exterior lighting, indicate automatic controls shut off lighting as a function of available daylight; include control sequence that also reduces lighting power by at least 30% between 12am-6am, or from 1 hour after closing to 1 hour before opening, or based upon motion sensor NA C405.5.1 Exterior building grounds lighting controls For building grounds fixtures greater than 100 watts, indicate on plans whether fixtures have efficacy greater than 80 lumens or; are controlled by motion sensor, or are exempt lighting per C405.5.2 Indicate location(s) of master control switch(es) i ntended to control multiple independent switches; circuit breaker may not be used as a master control switch; Verify that no 20 amp circuit controlled by a singl e switch or automatic control is loaded beyond 80% ADDITIONAL EFFICIENCY PACKAGE OPTION - ENHANCED DIGITAL LIGHTING CONTROLS To comply with additional efficiency package option, indicate on plans all interior lighting fixtures that are individually addressed and provided with continuous dimming, or exception taken; Include calculation of percent total installed interior lighting power that is configured with required enhanced lighting control functions (min 90% to comply with additional efficiency package option) Yes C405.2.5 - Item 7 Means of egress lighting NA C406.4 Enhanced digital lighting controls NA C405.2.5 (listed after C405.2.7) Area controls - Master control switches and circuit power limit NA C405.2.7 Exterior lighting controls NA C405.2.5 - Item 6 Lighting equipment for sale or demonstration C405.2.5 - Item 5 Lighting for non- visual applications NA The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Lighting, Motor, and Electrical Permit Checklist, P g. 3 LTG-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Title: Southworth Elementary Temporary Date 1/29/2021 Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes INTERIOR LIGHTING POWER & EFFICACY Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; E-001 Identify spaces eligible for lighting power exempti on on plans and in compliance forms; indicate the exception applied;N/A Identify lighting equipment eligible for lighting power exemption in fixture schedule and in compliance forms; indicate the exception applied; N/A Indicate that exempt lighting equipment is in addition to general area lighting and is controlled independently N/A Yes C405.3 Exit signs Indicate location of exit signs on plans and rated watts per fixture in lighting fixture schedule (maximum 5 watts per side)E-001 NA C405.1 Lighting in dwelling units - lamp efficacy If high efficacy exception is applied to permanently installed lighting fixtures in dwelling units, indicate in lighting fixture schedule if lamps in fixtures are high efficacy per R404.1. Calculate percentage of fixtures with high efficacy lamps in project (min 75% to comply with exception). Interior Lighting Power Calculation - Indicate compliance path taken NA C405.4.2.1 Building Area Method Complete required compliance forms – proposed wattage per building area does not exceed maximum allowed wattage per building area; identify locations of building areas on plans Yes C405.4.2.2 Space-By-Space Method Complete required compliance forms – total proposed wattage does not exceed maximum allowed wattage; identify locations of space types on plans, including retail display areas, lobby art & exhibit display areas, and ceiling heights as applicable SEE FORM ADDITIONAL EFFICIENCY PACKAGE OPTION - REDUCED INTERIOR LIGHTING POWER DENSITY NA C406.3 Reduced lighting power density To comply with additional efficiency package option, demonstrate in compliance forms that total connected interior lighting wattage is 25% less than the total maximum allowed lighting wattage via Building Area Method or Space-By-Space Method NA C406.3 Reduced lighting power density - dwelling unit lamp efficacy For project with dwelling units, to comply with additional efficiency package option indicate in lighting fixture schedule if lamps in interior fixtures have efficacy rating of 60 lumens per watt or more. Calculate percentage of fixtures with lamps that have this efficacy rating (min 95% to comply with option) EXTERIOR LIGHTING POWER & EFFICACY Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; Identify exterior applications eligible for lighting power exemption on plans and in compliance forms; indicate exception applied; Indicate that exempt exterior lighting is controlled independently from non-exempt exterior lighting; include exception claimed for each fixture or group of fixtures under exception category NA Table C405.5.2(1)Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ NA C405.5.1 Exterior building grounds lighting For building grounds fixtures rated at greater than 100 watts that are complying based on efficacy, indicate rated lamp efficacy (in lumens per watt) in fixture schedule NA C405.5.2 Exterior lighting power calculations Complete required compliance form – proposed wattage for exterior lighting plus base site allowed does not exceed maximum allowed C405.4.1 C405.4.2 Total connected interior lighting power NA C405.5.2 Total connected exterior lighting power Yes The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Lighting, Motor, and Electrical Permit Checklist, P g. 4 LTG-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Southworth Elementary Temporary Date 1/29/2021 Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes LIGHTING ALTERATIONS Where ≥ 50% of existing luminaires in interior space(s) or parking garage are replaced; indicate compliance path (building area or space-by-space method); include all new and existing-to- remain luminaires in compliance form (LTG-INT-BLD or LTG- INT-SPACE); indicate proposed lighting wattage does not exceed maximum allowed per compliance path Where < 50% of existing luminaires in interior space(s) or parking garage are replaced; indicate total existing lighting wattage in each space prior to alteration; include all new and existing-to-remain luminaires in LTG-INT-SPACE form; indicate proposed total lighting wattage in alteration area does not exceed total existing lighting wattage prior to alteration Where ≥ 50% of existing exterior lighting wattage is replaced; include all new and existing-to-remain luminaires in LTG-EXT form; indicate proposed total exterior lighting wattage does not exceed maximum allowed Where < 50% of existing exterior lighting wattage is replaced; indicate total existing lighting wattage prior to alteration; include all new and existing-to-remain luminaires in LTG-EXT form; indicate proposed total exterior lighting wattage does not exceed total existing wattage prior to alteration C503.6 Interior lighting wiring alterations Where new wiring is installed to serve new interior luminaires and /or luminaires are relocated to a new circuit; indicate lighting controls are provided (as applicable) - manual (C405.2.3); occupancy sensor (C405.2.1); daylight responsive (C405.2.4); specific application (C405.2.5); exit signs (C405.3) C503.6 Exterior lighting wiring alterations Where new wiring is installed to serve new exterior luminaires and /or luminaires are relocated to new circuit; indicate exterior lighting controls are provided (C405.2.7) NA C503.6 Lighting panel alterations Where a new lighting panel is installed or an existing panel is moved (all new raceway and conductor wiring); indic ate lighting controls are provided (as applicable) - same provisions as wiring alterations; time switch controls and manual light reduction controls (C405.2.2) Yes C503.6 Interior space reconfiguration Where interior space(s) is reconfigured (permanently installed walls or ceiling-height partitions); indicate lighting controls are provided (as applicable) - same provisions as lighting panel alterations E-201,E-202 NA C504.2 Lighting repairs Identify existing luminaires being upgraded with bulb and / or ballast replacement; indicate fixture alteration does not increase existing fixture wattage Identify spaces on plans where the building area type or space use type is being changed from one type to another per Tables C405.4.2(1) or (2) Indicate compliance path (building area or space-by-space method); include all new and existing-to-remain luminaires in compliance form (LTG-INT-BLD or LTG-INT-SPACE); indicate proposed lighting wattage does not exceed maximum allowed per compliance path RECEPTACLES Identify all controlled and uncontrolled receptacles on electrical plans in each space in which they are required; include receptacle configuration such as spacing between controlled and uncontrolled, duplex devices, etc; Indicate on plans whether the method of automatic control for each controlled receptacle zone is by occupant sensor or programmable time-of-day control NA C405.10 Controlled receptacles NA C505.1 Change of space use NA C503.6 Exterior lighting fixture alterations NA C503.6 Interior and parking garage lighting fixture alterations The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Lighting, Motor, and Electrical Permit Checklist, P g. 5 LTG-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Southworth Elementary Temporary Date 1/29/2021 Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes MOTORS, TRANSFORMERS, ELECTRIC METERS, INTERIOR TRANSPORTATION NA C405.6 Electrical transformers Include electrical transformer schedule on electrical plans; indicate transformer size, efficiency, or exception taken NA C405.7 Dwelling unit electrical energy consumption Indicate on electrical plans that each dwelling uni t in Group R-2 has a separate electrical energy meter NA C405.8 Electric motor efficiency Include all motors, including fractional hp motors, in electric motor schedule on electrical plans; indicate hp, rpm, rated efficiency, or exception applied For luminaires in each elevator cab, provide calculated average efficacy of combined fixtures that indicates efficacy is not less than 35 lumens per watt; Indicate rated watts per cfm for elevator cab ventilation fans do not exceed 0.33 watts per cfm; Indicate automatic controls that de-energize lighti ng and ventilation fans when elevator is stopped and unoccupied for a period of 15 minutes or more NA C405.9.2 Escalators and moving walks Indicate escalators comply with ASME A17.1/CSA B44; automatic controls are configured to reduce operational speed to the minimum permitted when not in use NA C405.9.3 Regenerative drive Indicate all one-way down or reversible escalators are provided with a variable frequency regenerative drive DOCUMENTATION AND SYSTEM REQUIREMENTS TO SUPPORT COMMISSIONING (Cx) Indicate that all electrical systems (receptacles, transformers, motors, vertical and horizontal transportation) for which the WSEC requires control functions and / or configuration to perform specific functions are required to be commissioned; E-001 Where total building lighting load is > 20 kW, or where total lighting load of luminaires requiring daylight sensing and / or occupancy control > 10 kW, indicate that all automatic lighting control systems are required to be commissioned; or provide building lighting power calculation demonstrating eligibility for exception; E-001 Indicate Cx requirements in plans and specifications for all applicable electrical and lighting control systems per C408;E-001 Include general summary with at minimum Items 1 thru 4 of the Cx plan per C408.1.2 including: narrative description of activities, responsibilities of the Cx team, schedule of activities including verification of project close out documentation per C103.6, and conflict of interest plan (if required); E-001 Include in general summary that a Cx project report or Compliance Checklist (Figure C408.1.4.2) shall be completed by the Certified Cx Professional and provided to the owner prior to the final electrical inspection E-001 NA C408.3.1 Functional performance testing criteria Identify in plans and specifications the intended operation of all equipment and controls during all modes of operation, including interfacing between new and existing-to-remain systems PROJECT CLOSE OUT DOCUMENTATION NA C103.6.3 Project close out documentation requirements Indicate in plans that project close out documentation is required including WSEC lighting compliance forms and calculations that document all interior and exterior lighting area and / or surface types, lighting power allowances and installed densities If "no" is selected for any question, provide explanation: Yes C405.13 C408.1.1 C408.1.2 C408.1.4.2 C103.6 Commissioning requirements in construction documents NA C405.9.1 Elevator cabs Yes C408.3 Scope of electrical power and lighting systems commissioning The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the End of Lighting, Motor & Transformer Permit Documents Checklist