2021.0070.BP0004 YMS Transition Permit Elec NRECLighting Summary LTG-SUM
Interior Lighting Plans Included
Exteriorlighitng is not in scope.
Compliance
forms do not
require a
password to
use.
Instructional and
calculating cells
are write-
protected.
Select method used in project.
Applicant Information. Provide contact information for individual who can
respond to inquiries about compliance form information provided.
Include PROJ-SUM form (included in envelope forms workboo k) with lighting compliance forms.
Permanently installed interior lighting fixtures in dwelling units comply with:
To comply with C406.4, no less than 90% of the total in stalled interior lighting power shall comply with the
required controls per C406.4.
All C405.2.1 - C405.2.8 Lighting Controls
Addition is combined with existing:
For interior lighting projects, include new + existing-to-remain interior lighting fixture wattage in
Proposed Lighting Wattage table in LTG-INT-BLD or LTG-INT-SPACE form.
For exterior lighting projects, include new + existing-to-remain exterior lighting fixture wattage in
Proposed Tradable and Proposed Non-Tradable Lighting Wattage tables in LTG-EXT form.
Refer to Section C502.2.6 for additional
requirements.
Lighting systems in addition area comply with all applicable
provisions as a stand alone new construction project
Lighting systems in additionare combined with existing
building lighting systems to demonstrate compliance
Additional Efficiency Package Option
C406.4 Enhanced Digital Lighting
C405.2 Exception 5 Luminaire Level
Lighting Controls (LLLC)
Dwelling unit lighting complies with WSEC Residential
provisions in lieu of WSEC Commercial provisions.
Building Area Method Space-by-space Method
Alteration the TI classroom areas. New classrooms will be provided with vacancy
sensors and photocell for day light dimming.
No Lighting Scope
Exterior Lighting Plans Included
Lighting Summary, cont. LTG-SUM
2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017
Interior and Exterior
Lighting Alterations
Existing interior lighting systems in areas under-going a change in space use are upgraded to
comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2).
Lamp and/or ballast replacement only
–existing total wattage not increased
New wiring installed to serve added
fixtures and/or fixtures relocated to
new circuit(s)
New or moved lighting panel
Interior space is reconfigured -
luminaires unchanged or relocated
50% or more of existing are replaced
50% or more replaced - Total lighting power of new + existing-to-remain fixtures shall comply with
total LPA per Sections C405.4.2 and C405.5.2. Include new + existing-to-remain fixtures in
Proposed Lighting Wattage table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form.
Less than 50% replaced -Total lighting power of new + existing-to-remainfixtures shall not exceed
the total lighting power prior to alteration. Include new + existing-to-remain fixtures in the Proposed
Lighting Wattage table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form.
50% threshold applies to number of luminaires for interior spaces and parking garages, and total
installed wattage for exterior luminaires.
Less than 50% of existing are replaced
New wiring or circuit -For interior lighting, provide required manual controls per C405.2.3,
occupancy sensor controls per C405.2.1, daylight responsive con trols per C405.2.4 and application
specific lighting controls per C405.2.5. For exterior lighting, provide required controls per C405.2.7.
New or moved panel -Provide all applicable lighting controls as noted for New Wiringand automatic
time switch controls per C405.2.2.
Reconfigured interior space -Provide all required lighting controls that apply to a new interior
space. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured
Select all Lighting Power and Lighting
Control elements that apply to the scope
of the retrofit project. If project includes a
combination of spaces where less than
50% of the existing fixtures are replaced
in some spaces, and 50% or more of the
fixtures are replaced in others, then
provide separate lighting power
compliance forms for the two retrofit
conditions. Spaces undergoing the same
type of retrofit may be combined into one
lighting power compliance form.
Refer to Section C503.6 for additional
requirements.
All alteration lighting controls shall be
commissioned per C408.3.
Identify interior spaces requiringLPD upgrade to the current Code in Proposed Lighting Wattage
table in LTG-INT-BLD or LTG-INT-SPACE form.
No changes are being made to
the interior or exterior lighting
systems and existing space
uses and configuration are not
changed.
Lighting, Motor, and Electrical Permit Checklist, P g. 1 LTG-CHK
2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017
Project Title: Southworth Elementary Temporary Date 1/29/2021
Applicability
(yes,no,na) Code Section Component Compliance information required in permit documents
Location in
Documents
Building Department
Notes
LIGHTING CONTROLS
Yes C405.2 Lighting controls,
general
For all lighting fixtures, indicate lighting control method on plans
for spaces and lighting zone(s) served, or exception taken E-001
NA C405.2
Luminaire level
lighting controls
(LLLC)
Indicate on plans all fixtures provided with LLLC in lieu of
C405.2 lighting controls; provide description of control
capabilities and performance parameters
NA C405.1 Lighting in dwelling
units
For permanently installed lighting fixtures in dwelling units,
indicate lighting control method on plans for spaces and lighting
zone(s) served, or demonstrate compliance with high efficacy
exception
Yes
C405.2.3
C405.2.1.1
C405.2.2.2
C405.2.4
C405.2.5
Manual controls
Indicate on plans the method of manual lighting control (whether
combined with occupancy sensor, automatic light reduction,
daylight responsive or specific application controls), location of
manual control device and area or specific application it serves
E-001
Yes
C405.2.2.1
C405.2.2.2
C405.2.3
Manual interior light
reduction controls
Indicate on plans which method of manual 50% lighting load
reduction is provided, or whether lighting load is reduced via
occupancy sensors or daylight responsive controls
E-201,E-202
Indicate on plans the method of automatic shut-off control
during unoccupied periods (occupancy sensor, time switch or
digital timer switch) for all lighting zones;
Indicate locations where automatic shutoff is provided by other
methods (occupancy sensor or digital timer switch) or which
time switch control exception applies
Indicate on plans the spaces served by occupancy sensors;E-201,E-202,E-001
Indicate whether occupancy sensor controls are configured to
be manual-on, automatic 50%-on, or serve a space eligible for
automatic 100%-on per exception
E-201,E-202,E-001
NA C405.2.1.2
Occupancy sensor
controls -
warehouses
Indicate aisleways and open areas in warehouse spaces
provided with occupancy sensor controls that reduce lighting
power by 50%
NA C405.2.2.1 Automatic time
switch controls
Indicate locations of override switches on plans and the lighting
zone(s) served, include area sq. ft.
N/A C405.2.6 Digital timer switch
Indicate digital timer switch control includes: manual on/off,
time delay, audible and visual indication of impending time-out
Indicate primary and secondary sidelight daylight zone areas on
plans, include sq. ft.;E-202
Indicate toplight daylight zone areas on plans, include sq. ft.;E-202
For small vertical fenestration assemblies (rough opening less
than 10 percent of primary daylight zone) where daylight
responsive controls are not required, provide fenestration area to
daylight zone calculation(s)
E-202
Indicate on plans lighting zone(s) served by daylight responsive
controls;E-202
Identify sidelight and toplight daylight zones that are not
provided with daylight sensing controls and the exception(s) that
apply;
N/A
Indicate on plans the lighting load reduction method -
continuous dimming, or stepped dimming that provides at least
two even steps between 0%-100% of rated power;
E-202
Indicate that daylight sensing controls are configured to
completely shut off all controlled lights in the lighting zone E-202
NA C405.2.5
Additional controls -
Specific application
lighting controls
Identify spaces and lighting fixtures on plans that require
specific application lighting controls per this section
Indicate on plans that display and accent lighting, and display
case lighting are controlled independently from both general
area lighting and other lighting applications within the same
space;
Indicate manual and automatic lighting control method
Yes C405.2.4.2
C405.2.4.3
Daylight zones -
Sidelight and toplight
NA C405.2.5 -
Items 1&2
Display and accent
lighting
Yes C405.2.4 Daylight responsive
controls
Yes C405.2.1
C405.2.1.1
Occupancy sensor
controls
NA C405.2.2 Method of automatic
shut-off control
The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the
Washington State Energy Code, Commercial Provisions.
Lighting, Motor, and Electrical Permit Checklist, P g. 2 LTG-CHK
2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017
Project Title: Southworth Elementary Temporary Date 1/29/2021
Applicability
(yes,no,na) Code Section Component Compliance information required in permit documents
Location in
Documents
Building Department
Notes
NA C405.2.5 -
Item 3
Hotel/motel guest
rooms
Indicate method of automatic control - vacancy or c aptive key
control of all installed luminaires and switched receptacles in
guest room
NA C405.2.5 -
Item 4
Supplemental task
lighting
Indicate method and location of automatic shut-off vacancy
control for supplemental task lighting, including under-shelf or
under-cabinet lighting
Indicate on plans eligible non-visual lighting applications,
include sq. ft. area of each lighting control zone;
Indicate on plans that non-visual lighting are controlled
independently from both general area lighting and other lighting
applications within the same space;
Indicate method of manual lighting control and appl icable
automatic lighting control
Indicate on plans that lighting equipment for sale or
demonstration are controlled independently from both general
area lighting and other lighting applications within the same
space;
Indicate method of manual lighting control and appl icable
automatic lighting control
Identify on plans egress fixtures that function as both normal
and emergency means of egress illumination;E-201,E-202
Provide calculation of lighting power density of total egress
lighting; E-001
If total egress lighting power density is greater than 0.02 W/sq.
ft., indicate on plans egress fixtures requiring automatic shut-off
during unoccupied periods;
Indicate method of automatic shut-off control E-001
Indicate on exterior lighting plans and fixture schedules the
automatic lighting control method, control sequence, and
locations served;
For building facade and landscape lighting, indicate automatic
controls shut off lighting as a function of dawn/dusk and fixed
opening/closing time;
For all other exterior lighting, indicate automatic controls shut off
lighting as a function of available daylight; include control
sequence that also reduces lighting power by at least 30%
between 12am-6am, or from 1 hour after closing to 1 hour
before opening, or based upon motion sensor
NA C405.5.1
Exterior building
grounds lighting
controls
For building grounds fixtures greater than 100 watts, indicate on
plans whether fixtures have efficacy greater than 80 lumens or;
are controlled by motion sensor, or are exempt lighting per
C405.5.2
Indicate location(s) of master control switch(es) i ntended to
control multiple independent switches; circuit breaker may not
be used as a master control switch;
Verify that no 20 amp circuit controlled by a singl e switch or
automatic control is loaded beyond 80%
ADDITIONAL EFFICIENCY PACKAGE OPTION - ENHANCED DIGITAL LIGHTING CONTROLS
To comply with additional efficiency package option, indicate on
plans all interior lighting fixtures that are individually addressed
and provided with continuous dimming, or exception taken;
Include calculation of percent total installed interior lighting
power that is configured with required enhanced lighting control
functions (min 90% to comply with additional efficiency package
option)
Yes C405.2.5 -
Item 7
Means of egress
lighting
NA C406.4 Enhanced digital
lighting controls
NA
C405.2.5
(listed after
C405.2.7)
Area controls -
Master control
switches and circuit
power limit
NA
C405.2.7 Exterior lighting
controls
NA C405.2.5 -
Item 6
Lighting equipment
for sale or
demonstration
C405.2.5 -
Item 5
Lighting for non-
visual applications
NA
The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the
Lighting, Motor, and Electrical Permit Checklist, P g. 3 LTG-CHK
2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017
Project Title: Southworth Elementary Temporary Date 1/29/2021
Applicability
(yes,no,na) Code Section Component Compliance information required in permit documents
Location in
Documents
Building Department
Notes
INTERIOR LIGHTING POWER & EFFICACY
Include all luminaires in lighting fixture schedule; indicate fixture
types, lamps, ballasts, and manufacturer's rated watts per
fixture;
E-001
Identify spaces eligible for lighting power exempti on on plans
and in compliance forms; indicate the exception applied;N/A
Identify lighting equipment eligible for lighting power exemption
in fixture schedule and in compliance forms; indicate the
exception applied;
N/A
Indicate that exempt lighting equipment is in addition to general
area lighting and is controlled independently N/A
Yes C405.3 Exit signs Indicate location of exit signs on plans and rated watts per
fixture in lighting fixture schedule (maximum 5 watts per side)E-001
NA C405.1 Lighting in dwelling
units - lamp efficacy
If high efficacy exception is applied to permanently installed
lighting fixtures in dwelling units, indicate in lighting fixture
schedule if lamps in fixtures are high efficacy per R404.1.
Calculate percentage of fixtures with high efficacy lamps in
project (min 75% to comply with exception).
Interior Lighting Power Calculation - Indicate compliance path taken
NA C405.4.2.1 Building Area Method
Complete required compliance forms – proposed wattage per
building area does not exceed maximum allowed wattage per
building area; identify locations of building areas on plans
Yes C405.4.2.2 Space-By-Space
Method
Complete required compliance forms – total proposed wattage
does not exceed maximum allowed wattage; identify locations of
space types on plans, including retail display areas, lobby art &
exhibit display areas, and ceiling heights as applicable
SEE FORM
ADDITIONAL EFFICIENCY PACKAGE OPTION - REDUCED INTERIOR LIGHTING POWER DENSITY
NA C406.3 Reduced lighting
power density
To comply with additional efficiency package option,
demonstrate in compliance forms that total connected interior
lighting wattage is 25% less than the total maximum allowed
lighting wattage via Building Area Method or Space-By-Space
Method
NA C406.3
Reduced lighting
power density -
dwelling unit lamp
efficacy
For project with dwelling units, to comply with additional
efficiency package option indicate in lighting fixture schedule if
lamps in interior fixtures have efficacy rating of 60 lumens per
watt or more. Calculate percentage of fixtures with lamps that
have this efficacy rating (min 95% to comply with option)
EXTERIOR LIGHTING POWER & EFFICACY
Include all luminaires in lighting fixture schedule; indicate fixture
types, lamps, ballasts, and manufacturer's rated watts per
fixture;
Identify exterior applications eligible for lighting power exemption
on plans and in compliance forms; indicate exception applied;
Indicate that exempt exterior lighting is controlled independently
from non-exempt exterior lighting; include exception claimed for
each fixture or group of fixtures under exception category
NA Table
C405.5.2(1)Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ
NA C405.5.1 Exterior building
grounds lighting
For building grounds fixtures rated at greater than 100 watts that
are complying based on efficacy, indicate rated lamp efficacy (in
lumens per watt) in fixture schedule
NA C405.5.2 Exterior lighting
power calculations
Complete required compliance form – proposed wattage for
exterior lighting plus base site allowed does not exceed
maximum allowed
C405.4.1
C405.4.2
Total connected
interior lighting power
NA C405.5.2
Total connected
exterior lighting
power
Yes
The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the
Lighting, Motor, and Electrical Permit Checklist, P g. 4 LTG-CHK
2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017
Southworth Elementary Temporary Date 1/29/2021
Applicability
(yes,no,na) Code Section Component Compliance information required in permit documents
Location in
Documents
Building Department
Notes
LIGHTING ALTERATIONS
Where ≥ 50% of existing luminaires in interior space(s) or
parking garage are replaced; indicate compliance path (building
area or space-by-space method); include all new and existing-to-
remain luminaires in compliance form (LTG-INT-BLD or LTG-
INT-SPACE); indicate proposed lighting wattage does not
exceed maximum allowed per compliance path
Where < 50% of existing luminaires in interior space(s) or
parking garage are replaced; indicate total existing lighting
wattage in each space prior to alteration; include all new and
existing-to-remain luminaires in LTG-INT-SPACE form; indicate
proposed total lighting wattage in alteration area does not
exceed total existing lighting wattage prior to alteration
Where ≥ 50% of existing exterior lighting wattage is replaced;
include all new and existing-to-remain luminaires in LTG-EXT
form; indicate proposed total exterior lighting wattage does not
exceed maximum allowed
Where < 50% of existing exterior lighting wattage is replaced;
indicate total existing lighting wattage prior to alteration; include
all new and existing-to-remain luminaires in LTG-EXT form;
indicate proposed total exterior lighting wattage does not exceed
total existing wattage prior to alteration
C503.6 Interior lighting wiring
alterations
Where new wiring is installed to serve new interior luminaires
and /or luminaires are relocated to a new circuit; indicate
lighting controls are provided (as applicable) - manual
(C405.2.3); occupancy sensor (C405.2.1); daylight responsive
(C405.2.4); specific application (C405.2.5); exit signs (C405.3)
C503.6 Exterior lighting
wiring alterations
Where new wiring is installed to serve new exterior luminaires
and /or luminaires are relocated to new circuit; indicate exterior
lighting controls are provided (C405.2.7)
NA C503.6 Lighting panel
alterations
Where a new lighting panel is installed or an existing panel is
moved (all new raceway and conductor wiring); indic ate lighting
controls are provided (as applicable) - same provisions as wiring
alterations; time switch controls and manual light reduction
controls (C405.2.2)
Yes C503.6 Interior space
reconfiguration
Where interior space(s) is reconfigured (permanently installed
walls or ceiling-height partitions); indicate lighting controls are
provided (as applicable) - same provisions as lighting panel
alterations
E-201,E-202
NA C504.2 Lighting repairs
Identify existing luminaires being upgraded with bulb and / or
ballast replacement; indicate fixture alteration does not increase
existing fixture wattage
Identify spaces on plans where the building area type or space
use type is being changed from one type to another per Tables
C405.4.2(1) or (2)
Indicate compliance path (building area or space-by-space
method); include all new and existing-to-remain luminaires in
compliance form (LTG-INT-BLD or LTG-INT-SPACE); indicate
proposed lighting wattage does not exceed maximum allowed
per compliance path
RECEPTACLES
Identify all controlled and uncontrolled receptacles on electrical
plans in each space in which they are required; include
receptacle configuration such as spacing between controlled
and uncontrolled, duplex devices, etc;
Indicate on plans whether the method of automatic control for
each controlled receptacle zone is by occupant sensor or
programmable time-of-day control
NA C405.10 Controlled
receptacles
NA C505.1 Change of space use
NA C503.6 Exterior lighting
fixture alterations
NA C503.6
Interior and parking
garage lighting fixture
alterations
The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the
Lighting, Motor, and Electrical Permit Checklist, P g. 5 LTG-CHK
2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017
Southworth Elementary Temporary Date 1/29/2021
Applicability
(yes,no,na) Code Section Component Compliance information required in permit documents
Location in
Documents
Building Department
Notes
MOTORS, TRANSFORMERS, ELECTRIC METERS, INTERIOR TRANSPORTATION
NA C405.6 Electrical
transformers
Include electrical transformer schedule on electrical plans;
indicate transformer size, efficiency, or exception taken
NA C405.7
Dwelling unit
electrical energy
consumption
Indicate on electrical plans that each dwelling uni t in Group R-2
has a separate electrical energy meter
NA C405.8 Electric motor
efficiency
Include all motors, including fractional hp motors, in electric
motor schedule on electrical plans; indicate hp, rpm, rated
efficiency, or exception applied
For luminaires in each elevator cab, provide calculated average
efficacy of combined fixtures that indicates efficacy is not less
than 35 lumens per watt;
Indicate rated watts per cfm for elevator cab ventilation fans do
not exceed 0.33 watts per cfm;
Indicate automatic controls that de-energize lighti ng and
ventilation fans when elevator is stopped and unoccupied for a
period of 15 minutes or more
NA C405.9.2 Escalators and
moving walks
Indicate escalators comply with ASME A17.1/CSA B44;
automatic controls are configured to reduce operational speed to
the minimum permitted when not in use
NA C405.9.3 Regenerative drive Indicate all one-way down or reversible escalators are provided
with a variable frequency regenerative drive
DOCUMENTATION AND SYSTEM REQUIREMENTS TO SUPPORT COMMISSIONING (Cx)
Indicate that all electrical systems (receptacles, transformers,
motors, vertical and horizontal transportation) for which the
WSEC requires control functions and / or configuration to
perform specific functions are required to be commissioned;
E-001
Where total building lighting load is > 20 kW, or where total
lighting load of luminaires requiring daylight sensing and / or
occupancy control > 10 kW, indicate that all automatic lighting
control systems are required to be commissioned; or provide
building lighting power calculation demonstrating eligibility for
exception;
E-001
Indicate Cx requirements in plans and specifications for all
applicable electrical and lighting control systems per C408;E-001
Include general summary with at minimum Items 1 thru 4 of the
Cx plan per C408.1.2 including: narrative description of
activities, responsibilities of the Cx team, schedule of activities
including verification of project close out documentation per
C103.6, and conflict of interest plan (if required);
E-001
Include in general summary that a Cx project report or
Compliance Checklist (Figure C408.1.4.2) shall be completed
by the Certified Cx Professional and provided to the owner prior
to the final electrical inspection
E-001
NA C408.3.1
Functional
performance testing
criteria
Identify in plans and specifications the intended operation of all
equipment and controls during all modes of operation, including
interfacing between new and existing-to-remain systems
PROJECT CLOSE OUT DOCUMENTATION
NA C103.6.3
Project close out
documentation
requirements
Indicate in plans that project close out documentation is
required including WSEC lighting compliance forms and
calculations that document all interior and exterior lighting area
and / or surface types, lighting power allowances and installed
densities
If "no" is selected for any question, provide explanation:
Yes
C405.13
C408.1.1
C408.1.2
C408.1.4.2
C103.6
Commissioning
requirements in
construction
documents
NA C405.9.1 Elevator cabs
Yes C408.3
Scope of electrical
power and lighting
systems
commissioning
The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the
End of Lighting, Motor & Transformer Permit Documents Checklist