2021.0088.FR0004 FA Yelm City Hall 3-2-21FIRE ALARM SYSTEMDATE:YELM CITY HALL
FIRE ALARM SYSTEM UPDATES
106 2ND STREET S.E.
YELM, WA 98597
REVISIONS:
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________3/4/2021SCALE:DRAWN BY:NLHPROJECT NUMBER:SHEET: OF 1global4security.com 360.693.1900 VANCOUVER, WAYELMHALL030421FFFFHSFACPVESTELECOPEN OFFICER.R.CONFSTORAGEOFFICEOFFICEOFFICEOFFICER.R.R.R.HHHHHHHHHHHHHHHHHHRECEPTIONCELLDOCSTORAGEBREAK ROOMSCALE: 1/8" = 1'FLOOR PLAN - EXISTING FIRE ALARM DEVICE LAYOUTFA-11AS SHOWN1.DO NOT START INSTALLATION BEFORE SYSTEM IS APPROVED BY THE AHJ.2.INSTALLATION TO BE DONE PER NFPA 72 (2016) AND ALL OTHER APPLICABLE CODES & STANDARDS.3.VERIFY EXACT LOCATIONS AND DIMENSIONS OF PANELS AND DEVICES BEFORE ROUGH IN.4.VERIFY ALL WIRING CONNECTIONS, BACKBOXES, CONDUITS, & CABLE TYPES BEFORE INSTALLATION.5.DO NOT RUN SLC AND VOICE CABLES IN SAME CONDUIT. MAINTAIN PROPER SEPARATION.IMPORTANT NOTES1.THIS IS AN UPDATE OF AN EXISTING FIRE ALARM SYSTEM.2.REPLACE OBSOLETE, FAILING FIRE ALARM PANEL WITH NEW POTTER 4064 FACP. REUSEEXISTING 120VAC DEDICATED CIRCUIT. RECONNECT EXISTING ZONES AND NAC CIRCUITS.PROVIDE TWO 12V-7AH BACKUP BATTERIES.3.INSTALL SOLE-PATH COMMERCIAL FIRE ALARM CELLULAR COMMUNICATOR ABOVE FACP.VERIFY EXACT LOCATION FOR IDEAL SIGNAL STRENGTH. TIE TO FACP 24VDC AUX POWERAND TO DACT CARD.4.INSTALL FIRE ALARM DOCUMENTS CABINET NEXT TO FACP. STORE FIRE ALARM RECORDDRAWINGS AND INSPECTION REPORTS.5.EXISTING PULL STATIONS, SMOKE DETECTORS, AND HEAT DETECTORS FROM ORIGINAL INSTALLARE OLD AND WILL BE REPLACED WITH NEW DETECTORS. REUSE EXISTING LOCATIONS ANDEXISTING WIRING. REPLACE END OF LINE RESISTORS AS NEEDED.6.EXISTING HORN-STROBES AND STROBES WILL BE REPLACED WITH NEW MODEL ANDSYNCHRONIZED BY FACP. REUSE EXISTING DEVICE LOCATIONS & EXISTING WIRING.7.NO ADDITIONAL DEVICES WILL BE ADDED TO THIS SYSTEM. ONLY EXISTING DEVICESUPGRADED.SCOPE OF WORK - SYSTEM UPDATESSYMBOLDESCRIPTIONMANUFACTURERPART NUMBERFIRE ALARM LEGENDEND OF LINE RESISTOREOLRQTY.FPULL STATION (EXISTING, TO BE REPLACED WITH NEW) FIRELITEBG-124SMOKE DETECTOR (EXISTING, TO BE REPLACED) SYSTEM SENSOR2W-BS1FIRE ALARM CONTROL PANEL (WITH DACT CARD)POTTERFACPPFC- 4064 & U20001YELM CITY HALL - FIRE ALARM UPDATES106 2ND STREET S.E.YELM, WA 98597HEAT DETECTOR (EXISTING, TO BE REPLACED) SYSTEM SENSOR5601PH19CEILING STROBE (EXISTING, TO BE REPLACED W/ NEW) SYSTEM SENSORDESIGNED & REVIEWED BY:LAURENT HNICET 87298, LEVEL: IICET FIRE ALARM SYSTEMSWALL HORN-STROBE (EXISTING, REPLACE W/ NEW) SYSTEM SENSORFIRE ALARM CELLULAR COMMUNICATOR (24VDC)TELGUARDCELLTG-7FP1FIRE ALARM DOCUMENTS CABINETDOCBOXDOCDOCBOX142SCRLPC2RLFIRE ALARM SYSTEM - RISER DIAGRAMFACP2x 12V-7AHBATTERIESELECTRIC ROOMPOTTERAUX PWR(EXISTING) 120VACDEDICATED & LOCKABLE CKT(EXISTING LOCATION)ZONE #1 - SMOKE ABOVE FACP (EXISTING) FIRE ALARMDOCUMENTSNEXT TO FACPCABINETPFC-4604(NEW)TO MONITORING STATIONZONE #2 - HEAT DETECTORS (EXISTING)ZONE #3 - HEAT DETECTORS (EXISTING)ZONE #4 - SPAREZONE #5 - SPAREZONE #6 - SPARENAC #1 - STROBES & HORN-STROBES (EXISTING)NAC #2 - SPARENAC #3 - SPARENAC #4 - SPAREFIRE ALARMCELLULARNEXT TO FACPDIALER(NEW)LINE#1 FROM U2000 CARDTOTAL ALARMCURRENT, A10242.8580.1193.6153.0130.1540.926ALARMCURRENT, ASUPERV.CURRENT, ADESCRIPTIONNOTIFICATION APPLIANCESQTYMODULETOTAL SUPERVISORY CURRENTTOTAL ALARM AND SUPERVISORY CAPACITYTOTAL AMP-HOURS REQUIRED (AFTER 20% DERATING)TOTAL SUPERVISORY CAPACITYTOTAL STANDBY HOURS TOTAL ALARM CAPACITYALARM PERIOD IN MINUTESTOTAL ALARM CURRENTTOTAL SUP.CURRENT, A0.2350000.2350000.070000PFC-40641FIRE ALARM CONTROL PANEL0.0700000.1300000.0001000.1300000.0001002W-B1SYSTEM SENSOR SMOKE DETECTORPROVIDE TWO (2) 12V-7AH BATTERIESBATTERY CALCULATION FOR FACP0.1100000.0180000.1100000.018000TG-7FP1TELGUARD CELLULAR MODULE (24VDC)0.0230000.0160000.0230000.016000U20001POTTER DACT CARD (TO INTERFACE WITH CELL PANEL)TRANSMIT ALARM TO SUPERVISING STATIONDISPLAY AT FACPTRANSMIT SUPERVISORY TO SUPERVISING STATIONTRANSMIT TROUBLE TO SUPERVISING STATIONSOUNDS EVACUATION SIGNAL (PER AHJ)C. TROUBLETO RECEIVE SEPARATE & DISTINCTSIGNALS AS FOLLOWS:CENTRAL STATION ALARM SERVICENOTES:B. SUPERVISORYA. ALARMFIRE ALARMSEQUENCEOFOPERATIONSTROUBLE CONDITION AT PANELACTIVATION OF SMOKE DETECTORLOSS OF AC POWEROPEN CIRCUITACTIVATION OF HEAT DETECTORACTIVATION OF MANUAL PULL STATIONSYSTEM SENSOR 15CD HORN-STROBESYSTEM SENSOR 15CD STROBESYSTEM SENSOR 75CD HORN-STROBESYSTEM SENSOR 30CD HORN-STROBE1110P2RL-75P2RL-30SCRL-15P2RL-150.0000.0000.0000.0000.1210.0740.0000.0000.0410.0540.0000.0000.1210.0740.0410.000SYSTEM SENSOR 30CD STROBE3SCRL-300.0000.0630.0000.1890.425SYSTEM SENSOR 75CD WEATHERPROOF HORN-STROB0P2RK-750.0000.1760.0000.000CIRCUIT #1TOTAL CURRENT CIRCUIT #10.1200000.0150000.0400000.005000ZONES3FACP ZONES