Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2021.0088.FR0004 Data Sheets Yelm
GLOBAL SECURITY 3212 Main Street Vancouver, WA 98663 global4security.com 360.693.1900 Reference: Fire Alarm System: system update Yelm City Hall 106 2nd Street S.E. Yelm, WA 98597 Device Data Sheets March 2021 PFC-4064 Conventional Fire Alarm Control Panel 8830139 - REV E • 9/19 page 1 OF 5 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com Features • 6 programmable Initiating Device Circuits • System is expandable to 192 input circuits using the IDC-6 expansion module • 5.0 amp power Supply • 4 Notification Circuit rated at 3.0 Amps • Strobe Synchronization for gentex, aMSeCO, System Sensor and Cooper/Wheelock • One programmable auxiliary output rated at 1.0 a • 4 x 20 LCD display with system LeDs for clear system status • P-Link RS-485 bus supports 31 system accessories • Built-in ethernet Connection with listed Ip Communicator • Ability to E-mail system status, reports and system configuration • Service Reminder e-mails Dimensions 18 1/2” H x 14 1/4 W x 4 3/4” D enclosure 18 gauge cold rolled steel with removable locked door with Lexan viewing window aC Mains 5.0 amp @ 120 VaC 60 Hz 2.0 amp @ 240 VaC 50 Hz Battery 70 ma Standby 235 mA Alarm Temperature and Humidity Range 32° to 120° (0°C to 49°C) with a maximum humidity of 93% non-condensing. Standards NFpa 70, 72 Description The pFC-4064 Conventional Fire panel is a compact, expandable panel designed to monitor all facets of a fire alarm system and communicate the status to a monitoring station. The pFC-4064 panel is a listed and approved microprocessor based conventional fire panel and complies with UL-864, NFpa-70, and NFpa-72. The panel is provided with six (6) inputs and four (4) 24VDC, 3.0 Amp Notification Appliance Circuits (NAC) with strobe synchronization. The 5.0 Amp power supply provides ample power to meet any jurisdictions requirements and will charge up to two (2) 55 amp/hour batteries. In addition, the panel has the potter p-Link for connection to system accessories. The panel also has a 1.0 amp auxiliary power output for controlling ancillary fire alarm functions. The control panel is in a metal cabinet with a key lock and lexan window for viewing the system status. The printed circuit assembly is mounted for quick removal and installation to allow the cabinet to be installed with minimal effort. The cabinet houses up to two (2) 7 AH or two (2) 12 AH batteries. The display is an eighty (80) character LCD with system status LEDs. The system status is clearly displayed and the panel includes a history buffer for past events. The key pad allows navigation into the system menu, limited programming and system control. The condition and events on the panel are clearly displayed to allow the user and installer to determine the system status. The panel will support up to thirty-one (31) system accessories. Technical Specifications LISTED 8830139 - REV E • 9/19 page 2 OF 5 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com PFC-4064 Conventional Fire Alarm Control Panel 2-Wire Smoke Detector Compatibility Detector Model Identifier Base Model Identifier SYSTEM SENSOR (Brk) (Max. No. Of Detectors Per Zone Is 20) 1400 a N/a N/a 2400 a N/a N/a 2400TH a N/a N/a 2W-B a N/a N/a 2WT-B a N/a N/a DETECTION SYSTEM (Max. No. Of Detectors Per Zone Is 25) DS250 a MB2W/MB2WL a DS250TH a MB2W/MB2WL a ESL (Max. No. Of Detectors Per Zone Is 25) 611U S10 601U S00 611UD S10 601U S00 611UT S10 601U S00 612U S10 601U S00 612UD S10 601U S00 613U5 S10 601U S00 611UD S10 609U10 S00 612UD S10 609U10 S00 425C S10 N/a N/a 425CT S10 N/a N/a HOCHIKI (Max. No. Of Detectors Per Zone Is 25) SLR-24 HD-3 HSC-221R HB-71 HSB-221 HB-54 HSB-221N HB-54 NS6-221 NS4-221 NS6-220 HB-3 SLR-24H HD-3 HSC-221R HB-71 HSB-221 HB-54 HSB-221N HB-54 NS6-221 NS4-221 SIJ-24 HD-3 HSC-221R HB-71 HSB-221 HB-54 HSB-221N HB-54 NS6-221 NS4-221 8830139 - REV E • 9/19 PAgE 3 OF 5 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com PFC-4064 Conventional Fire Alarm Control Panel Detector Model Identifier Base Model Identifier FENWAL (Max. No. Of Detectors Per Zone Is 25) CpD-7051 I51Fe1 2-WIRe Fe51a pSD-7155 p55Fe1 2WRLT Fe52a pSD-7156 p56Fe1 2WRB Fe55a all of the above Fenwal detectors and bases can be used in any combination. Retrofit Base Adaptor 70-501000-003, Identifier MAFE1 (for series 70-201000 Bases, Models -001, -002, -003, and -005). Duct Housing with Detector Base DH-51, Identifier DH22FE5 (for CPD-7051 and PSD-7155 detectors only). POTTER (Max. No. Of Detectors Per Zone Is 25) CpS-24 HD-3 (HOCHIKI)SB-46 HB-4 (HOCHIKI) SB-93 HB-3 (HOCHIKI) pS-24H HD-3 (HOCHIKI)SB-46 HB-71 (HOCHIKI) HB-54 (HOCHIKI) IS-24 HD-3 (HOCHIKI)SB-46 HB-71 (HOCHIKI) HB-54 (HOCHIKI) NOTE: If using a mix of System Sensor and other smoke detectors, a maximum of 20 detectors shall be permitted. 8830139 - REV E • 9/19 page 4 OF 5 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com PFC-4064 Conventional Fire Alarm Control Panel User Interface Ethernet/I.P. Connection P-Link The pFC-4064 is shipped standard with an ethernet connection. This connection is the programming port and may be connected to a building Wide Area Network (WAN) or Local Area Network (LAN). Once connected to the Internet, the panel may be selectively programmed to e-mail alarm conditions, trouble conditions, supervisory conditions, test, event History and detector status. an e-mail may be sent to the panel and the panel will e-mail the event history, detector status, configuration file or server status to an authorized e-mail account. In addition, reminders may be set to send an e-mail for service, testing or other conditions. In addition, the ethernet connection is UL listed as an Ip communicator. The Ip communicator is listed to report to the UL listed Sur-gard III Ip receiver. The Ip communicator replaces the traditional less reliable alarm communicator transmitter that utilized telephone lines. The Ip communicator is an active method of connection and communication to the monitoring station. The pFC-4064 has a proprietary communication protocol that communicates through a RS-485 connection to field devices. Up to 31 devices may be connected to a single P-Link connection. The p-Link includes the communication terminals and regulated 24 VDC connection for the field devices. The field devices may be any of the following: IDC-6 – Initiating device circuit expander, provides an additional six (6) inputs. RA-6075R – 2 x 16 LCD annunciator with a key pad in a locked metal enclosure. RA-6500R(F) – 4 x 40 LCD annunciator with a key pad in a locked metal enclosure. Flush mount version available. LED-16(F) – 16 LeD annunciator with common indicators in a locked metal enclosure. Flush mount version available. PSN-1000(E) – 10 amp, remote intelligent power supply with 6 NaCs, 2 Inputs and a p-Link repeater. CA-4064 – Class a convertor that converts the NaCs and p-Link connection. UD-2000 – UL listed, Dual line telephone alarm communicator. DRV-50 – LeD driver expander, used to connect up to 50 LeDs in a graphic display . FCB-1000 – Fire communication bridge, provides remote mounting of the ethernet connection. FIB-1000 – Fiber interface module, used to extend p-Link to multi- mode fiber (2 required). RLY-5 – Relay module, provides 5 form C relay contacts rated at 3.0 amps 24VDC/125aC. SPG-1000 – Serial parallel gateway, allows for the connection to a serial or parallel printer. The fire alarm control panel has a 4 x 20 LCD display to provide information to the system status. The keypad has navigation keys to allow manipulation of the Menu on board the panel. The panel is shipped standard with the following LeDs: • aC power - green • alarm - Red • earth Fault - amber • Supervisory - amber • Silenced - amber • Trouble - amber The common buttons include a Silence, Reset, acknowledge, and Drill. all of the buttons are accessible once the locked door is opened. The FIB-1000, FCB-1000 and the SPG-1000 may be installed in the stacker bracket or ordered with the optional rack mount enclosure. MC-1000 Multi-Connect allows up to sixty-three panels to share a single reporting technology. AE-2 – Two card expansion cabinet. AE-8 – eight card expansion cabinet. AE-14 – Fourteen card expansion cabinet. 8830139 - REV E • 9/19 page 5 OF 5 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com PFC-4064 Conventional Fire Alarm Control Panel BOTTOM LEFT SIDE TOP 18.60"18.10"DEPTH 4.63" 3.95" 14.48" 14.78" RIGHT SIDE Dimensions Ordering Information Model Description Stock No. pFC-4064 Fire alarm Control panel 3992360 Replacement Board 3992363 800.229.2326 | 3225 Cumberland Blvd SE • Suite 300 • Atlanta, GA 30339 • USA | telguard.com ©2021 Telguard | Telguard and the Telguard Logo are registered trademarks of Telular Corporation. | Telular is a business unit of AMETEK, Inc. All Rights Reserved. 022021RevA For the most current product specifications and UL Listings visit telguard.com/tg-7fp. In Canada, cellular data may be carried by Rogers, Bell, Telus or SaskTel. UL Listings (AT&T and Verizon) • 864 Commercial Fire • 1610 Central Station ULC Listings (AT&T Only) • S559 Commercial Fire • S304 Commercial Burglary Certifications • California State Fire Marshal Package Contents • TG-7FP universal communicator • Terminal blocks • LTE antenna Specifications Power Consumption Standby: 18mA @ 24VDC 40mA @ 12VDC Transmit: 110mA @ 24VDC 200mA @ 12VDC Compatible Formats CID, SIA, Pulse (4x2, 3x1), Radionics (IIe/3a2,4), DMP Enclosure • Compact-size red plastic enclosure • 3 knockouts for 1/2” conduit connectors • LEDs always visible on cover • Built-in tamper switch • External access to RSSI & Reset buttons Physical Details Size (without antenna) 8.25 x 5.75 x 2.0 in (20.96 x 14.61 x 5.08 cm) Shipping Weight 2.2 lbs (1.0 kg) Compatible Accessories • ACD-12, ACD-35, ACD-50, and ACD-100: 12/35/50/100 ft of low loss, high performance antenna cable • HGDL-0: High gain directional antenna • EXDL-0: External antenna COMMERCIAL FIRE Feature-rich, with updated technology, the Telguard TG-7FP is all about saving time and money. It starts with a 5G (LTE-M) communicator that powers off the alarm panel and costs less to purchase and install than comparable models. Add to that the savings your customers enjoy every month from replacing expensive landlines with economical cellular service. Then, top it all off with the RMR that goes to you, not the Telco. Reliable alarm signal communication is a critical element to a fire system’s foundation. The TG-7FP delivers the features and functionality needed most, and it’s perfect for many applications where space, access to power, and budget are considerations. Everything about installation is a breeze. Since the TG-7FP powers directly from a 12 or 24VDC alarm panel, there’s no need for an electrician to install an outlet. Plus, there’s no plug-in adapter or on-board battery to worry about. It all means you’re in, you’re out, and you’re off to the next jobsite. Setting up the TG-7FP couldn’t be easier. You can apply the settings you need from our website or with the Telguard Tools app – you can even do it in advance from the office. Of course, you can configure it to work with the central station of your choice. PRODUCT FEATURES Powers directly from the fire panel’s 12V/24V auxiliary power source. Operates on LTE-M networks, for lower power consumption and better building penetration. Interfaces with fire panels using a single DACT connection for universal compatibility. Backed by world-class Telguard support. AT&T model available now. Verizon model coming soon. Agency Listings Photoelectric Smoke Detectors System Sensor i3™ series smoke detectors represent significant advancement in conventional detection. The i3 family is founded on three principles: installation ease, intelligence, and instant inspection. Features Plug-in detector line, mounting base included• Large wire entry port• In-line terminals with SEMS screws• Mounts to octagonal and single-gang back boxes, 4-square back • boxes, or direct to ceiling Stop-Drop ’N Lock attachment to base• Removable detector cover and chamber• Built-in remote maintenance signaling• Drift compensation and smoothing algorithms• Simplified sensitivity measurement • Wide-angle, dual-color LED indication• Loop testing via EZ Walk feature• Built-in test switch• Installation ease. The i3 line redefines installation ease with its plug-in design. This allows an installer to pre-wire bases (included with heads). The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods as well as direct mounting with drywall anchors. To complete the installation, i3 heads plug into the base with a simple Stop-Drop ’N Lock™ action. Intelligence. i3 detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the i3 line to minimize nuisance alarms. 2-wire i3 detectors can generate a remote LED- indicated maintenance signal when connected to the 2W-MOD2 loop test/maintenance module or a panel equipped with the i3 protocol. The SENS-RDR, a wireless device, displays the sensitivityof i3 detectors in terms of percent-per-foot obscuration. Instant inspection. The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector’s condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol, the EZ Walk loop test feature is available on 2-wire i3 detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. 2093290-01-E7272-1653:1523011446S911 3180932 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2009 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. A05-0318-007 • 6/09 • #2169 Ordering Information Model Thermal Wiring Alarm Current 2W-B No 2-wire 130 mA max. limited by control panel 2WT-B Yes 2-wire 130 mA max. limited by control panel 4W-B No 4-wire 20 mA @ 12 V, 23 mA @ 24 V 4WT-B Yes 4-wire 20 mA @ 12 V, 23 mA @ 24 V Accessories 2W-MOD2 2-wire loop test / maintenance module RT Removal / replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 inch (16.76 cm) diameter Smoke Detector Specifications Architectural/Engineering Specifications Smoke detector shall be a System Sensor i3 Series model number_______, listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4WT-B) with thermal sensor rated at 135°F (57.2°C). The detector shall include a mounting base for mounting to 3½-inch and 4-inch octagonal, single-gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws. The detector shall allow pre-wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual- color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24 V non-polarized Minimum: 8.5 V Maximum: 35 V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2-wire: 50 µA maximum average; 4-wire: 50 µA maximum average Maximum Alarm Current 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12 V, 23 mA @ 24 V Peak Standby Current 2-wire: 100 µA; 4-wire: n/a Alarm Contact Ratings 2-wire: n/a; 4-wire: 0.5 A @ 30 V AC/DC Physical Specifications Dimensions (including base)5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 oz (178 g) Operating Temperature Range 2W-B and 4W-B: 32°F to 120°F (0°C to 49°C); 2WT-B and 4WT-B: 32°F to 100°F (0°C to 37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (57.2°C) fixed Freeze Trouble 2WT-B and 4WT-B only: 41°F (5°C) Sensitivity 2.5%/ft nominal Input Terminals 14 to 22 AWG Mounting 3½-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Modes Power-Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby)Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Agency Listings 5600 Series Mechanical Heat Detectors System Sensor’s 5600 series mechanical heat detectors offer a low-cost means for property protection against fire, and for non-life-safety installations where smoke detectors are inappropriate. Features • Multiple configurations for installations: – Single- and dual-circuit models – Fixed temp and combination fixed- temp/rate-of-rise 135°F or 194°F ratings. • Plain housing for residential installations (Model 5601P) • Easy-to-use terminal screws • A broad range of back box mounting options: – Single gang – 3.5˝ and 4˝ Octagonal – 4˝ square with square to round plaster ring • Reversible mounting bracket Multiple configurations. The 5600 series offers a full-line of configurations to accommodate a broad range of applications. Both single- and dual-circuit models are available for low- and high- temperature ratings with either fixed temperature or combination fixed temperature/rate-of-rise (ROR) activation. The ROR element of the fixed/ROR models is restorable to accommodate field-testing. Installation flexibility. To satisfy a variety of installation needs, the 5600 series easily mounts to single-gang and octagonal back boxes. And these models accommodate four-square back boxes, when used with a square to round plaster ring. The reversible mounting bracket permits both flush- and surface-mount back box installations. Visual identification. The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method, as well as the temperature rating, in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX, while combination fixed/ rate-of-rise units are marked FX/ROR. The 5600 series also provides a post-activation indicator in the form of a collector. When the detector is activated, the collector drops from the unit, making it easy to identify the unit in alarm. S2101 3016008 CS630 7270-1653:0167 5601P 5621 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2013 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. SPDS30001 • 7/13 Specifications Architectural/Engineering Specifications Mechanical heat detector shall be a System Sensor 5600 series model number _________, listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems. The detector shall be either a single-circuit or a dual-circuit type, normally open. The detector shall be rated for activation at either 135°F (57°C) or 194°F (90°C), and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature/rate-of-rise thermal sensor. The rate-of-rise element shall be activated by a rapid rise in temperature, approximately 15°F (8.3°C) per minute. The detector shall include a reversible mounting bracket for mounting to 3½-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a square to round plaster ring. Wiring connections shall be made by means of SEMS screws that shall accommodate 14–22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method. The rate-of-rise element of combination fixed temperature/rate-of-rise models shall be restorable, to allow for field-testing. The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Physical/Operating Specifications Maximum Installation Temperature 5601P, 5603, 5621, and 5623: 100°F (38°C) 5602, 5604, 5622, and 5624: 150°F (65.6°C) Operating Humidity Range 5 to 95% RH non-condensing Dimensions with mounting bracket Diameter: 4.57 inches (11.6cm) Height: 1.69 inches (4.3cm) Alarm Temperature 5601P, 5603, 5621, and 5623: 135°F (57°C) 5602, 5604, 5622, and 5624: 194°F (90°C) Weight 6 oz. (170 grams) Rate-of-Rise Threshold 15°F (8.3°C) rise per minute (models 5601P, 5602, 5621, and 5622 only) Mounting 3½-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring Electrical Specifications Operating Voltage / Contact Ratings 6–125VAC / 3A 6–28VDC / 1A 125VDC / 0.3A 250VDC / 0.1A Input Terminals 14–22 AWG Ordering Information Model Circuit Identification Method on Exterior Temperature Rating Activation UL Protected Spacing – 10 Foot Ceiling* 5601P Single None 135°F (57°C)Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5602 Single Lettering 194°F (90°C)Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5603 Single Lettering 135°F (57°C)Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) 5604 Single Lettering 194°F (90°C)Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) 5621 Dual Lettering 135°F (57°C)Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5622 Dual Lettering 194°F (90°C) Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5623 Dual Lettering 135°F (57°C) Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) 5624 Dual Lettering 194°F (90°C)Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) *NOTE: Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. 5601P FX/ROR194°F/9 0 °C5602, 5622 FX135°F/5 7 °C5603, 5623 FX194°F/9 0 °C5604, 5624 FX/ROR135°F/5 7 °C5621 DF-52004:A1 • 04/22/08 — Page 1 of 2 BG-12 Series Manual Fire Alarm Pull Stations Conventional Initiating Devices DF-52004:A1 • F-050 General The Fire·Lite BG-12 Series is a cost-effective, feature-packed series of non-coded manual fire alarm pull stations. It was designed to meet multiple applications with the installer and end-user in mind. The BG-12 Series features a variety of mod- els including single- and dual-action versions. The BG-12 Series provides Fire·Lite Alarm Control Panels (FACPs), as well as other manufacturers’ controls, with a man- ual alarm initiating input signal. Its innovative design, durable construction, and multiple mounting options make the BG-12 Series simple to install, maintain, and operate. Features • Aesthetically pleasing, highly visible design and color. • Attractive contoured shape and light textured finish. • Meets ADA 5 lb. maximum pull-force. • Meets UL 38, Standard for Manually Actuated Signaling Boxes. • Easily operated(single- or dual-action), yet designed to pre- vent false alarms when bumped, shaken, or jarred. • PUSH IN/PULL DOWN handle latches in the down position to clearly indicate the station has been operated. • The word “ACTIVATED” appears on top of the handle in bright yellow, further indicating operation of the station. • Operation handle features white arrows showing basic opera- tion direction for non-English-speaking persons. • Braille text included on finger-hold area of operation handle and across top of handle. • Multiple hex- and key-lock models available. • U.S. patented hex-lock needs only a quarter-turn to lock/ unlock. • Station can be opened for inspection and maintenance with- out initiating an alarm. • Product ID label viewable by simply opening the cover; label is made of a durable long-life material. • The words “NORMAL” and “ACTIVATED” are molded into the plastic adjacent to the alarm switch (located inside). • Four-position terminal strip molded into backplate. • Terminal strip includes Phillips combination-head captive 8/32 screws for easy connection to Initiating Device Circuit (IDC). • Terminal screws backed-out at factory and shipped ready to accept field wiring (up to 12 AWG/3.1 mm²). • Terminal numbers are molded into the backplate, eliminating the need for labels. • Switch contacts are normally open. • Can be surface-mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box. • Backplate is large enough to overlap a single-gang backbox cutout by 1/2" (1.27 cm). • Optional trim ring (BG12TR). • Spanish versions (FUEGO) available (BG-12LSP, BG-12LPSP). • Designed to replace the Fire·Lite legacy BG-10 Series. • Models packaged in attractive, clear plastic (PVC), clam- shell-style, Point-of-Purchase packages. Packaging includes a cutaway dust/paint cover in shape of pull station. Construction • Cover, backplate and operation handle are all molded of durable polycarbonate material. • Cover features white lettering and trim. • Red color matches System Sensor’s popular SpectrAlert® Advance horn/strobe series. Operation The BG-12 manual pull stations provide a textured finger-hold area that includes Braille text. In addition to PUSH IN and PULL DOWN text, there are arrows indicating how to operate the sta- tion, provided for non-English-speaking people. Pushing in and then pulling down on the handle activates the normally-open alarm switch. Once latched in the down position, the word “ACTIVATED” appears at the top in bright yellow, with a portion of the handle protruding at the bottom as a visible flag. Resetting the station is simple: insert the key, twist one quarter- turn, then open the station’s front cover, causing the spring- loaded operation handle to return to its original position. The alarm switch can then be reset to its normal (non-alarm) position manually (by hand) or by closing the station’s front cover, which automatically resets the switch.52004p4c.jpg Page 2 of 2 — DF-52004:A1 • 04/22/08 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Fire•Lite® Alarms, SpectrAlert® Advance, and System Sensor® are registered trademarks of Honeywell International Inc. ©2008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Made in the U.S. A. Specifications PHYSICAL SPECIFICATIONS: ELECTRICAL SPECIFICATIONS: Switch contact ratings: gold-plated; rating 0.25 A @ 30 VAC or VDC. ENGINEERING/ARCHITECTURAL SPECIFICATIONS Manual Fire Alarm Stations shall be non-code, with a key- or hex-operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key or hex. An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red colored LEXAN (or polycarbonate equivalent) with clearly visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Under- writers Laboratories listed. NOTE: *The words “FIRE/FUEGO” on the BG-12LSP shall appear on the front of the station in white letters, approximately 3/4" (1.905 cm) high. Agency Listings and Approvals The listings and approvals below apply to the BG-12 Series pull stations. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. •C(UL)US: S711 •FM Approved •CSFM: 7150-0075:184 •MEA: 67-02-E •Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. Product Line Information BG-12S: Single-action pull station with pigtail connections, hex lock. BG-12SL: Same as BG-12 with key lock. BG-12: Dual-action pull station with SPST N/O switch, screw terminal connections, hex lock. BG-12L: Same as BG-12 with key lock. BG-12LSP: Same as BG-12L with English/Spanish (FIRE/ FUEGO) labeling. BG-12LOB: Same as BG-12L with “outdoor use” listing. Includes outdoor listed backbox, and sealing gasket. BG-12LO: Same as BG-12L with “outdoor use” listing. Does not include backbox. BG-12LA: Same as BG-12L with auxiliary contacts. BG-12LPS: Dual-action pull station with pre-signal option. BG-12LPSP: Same as BG-12LPS with English/Spanish (FIRE/ FUEGO) labeling. SB-10: Surface-mount backbox, metal. SB-I/O: Surface-mount backbox, plastic. (Included with BG- 12LOB.) BG12TR: Optional trim ring for semi-flush mounting. 17003: Keys, set of two. (Included with key-lock pull stations.) 17007: Hex lock, 9/64”. (Included with hex-lock pull stations.) NOTE: For addressable BG-12LX models, see data sheet DF- 52013. pull station SB-I/O SB-10 Height 5.5 inches (13.97 cm) 5.601 inches (14.23 cm) 5.5 inches (13.97 cm) Width 4.121 inches (10.47 cm) 4.222 inches (10.72 cm) 4.121 inches (10.47 cm) Depth 1.39 inches (3.53 cm) 1.439 inches (3.66 cm) 1.375 inches (3.49 cm) 52004dim.tbl Agency Listings 7125-1653:0504 7135-1653:0503 S5512 S4011 FM approved except for ALERT models 3057383, 3057072 AVDS865-05 • 2/22/2018 • Page 1 Features • Updated Modern Aesthetics • Small profile devices for Horns and Horn Strobes • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field-selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Strobes and Horn Strobes listed for wall mounting only • Horns listed for wall or ceiling use The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. AVDS865-05 • 2/22/2018 • Page 2 L-Series Specifications Architect/Engineer Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 17/8-inch back box, 4 × 4 × 1½-inch back box, 4-inch octagon back box, or double-gang back box. L-Series compact products shall mount to a single-gang 2 × 4 × 17⁄8 -inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize Strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 × 411/16 × 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens)5.6˝ L × 4.7˝ W × 1.91˝ D (143 mm L × 119 mm W × 49 mm D) Compact Wall-Mount Dimensions (including lens)5.26” L x 3.46” W x 1.91” D (133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6˝ L × 4.7˝ W × 1.25˝ D (143 mm L × 119 mm W × 32 mm D) Compact Horn Dimensions 5.25” L x 3.45” W x 1.25” D (133 mm L x 88 mm W x 32 mm D) 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. AVDS865-05 • 2/22/2018 • Page 3 Horn and Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9*Coded High 85 90 90 10*3.1 KHz Coded High 84 89 89 * Settings 9 and 10 are not available on 2-wire horn strobes. Temporal coding must be provided by the NAC. If the NAC voltage is held constant, the horn output remains constantly on. UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC DC FWR Candela Range 15 88 43 60 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 UL Max. Current Draw (mA RMS), Wall Horn Strobe, Candela Range (15–185 cd) DC Input 8–17.5 Volts 16–33 Volts 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 FWR Input 16–33 Volts 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 UL Max. Horn Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Current Draw Data Horn Tones and Sound Output Data 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2018 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS865-05 • 2/22/2018 L-Series Dimensions Model Description Wall Horn Strobes P2RL 2-Wire, Horn Strobe, Red P2WL 2-Wire, Horn Strobe, White P2GRL 2-Wire, Compact Horn Strobe, Red P2GWL 2-Wire, Comp 2 fils act Horn Strobe, White P2RL-P 2-Wire, Horn Strobe, Red, Plain P2WL-P 2-Wire, Horn Strobe, White, Plain P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO P2WL-SP 2-Wire, Horn Strobe, White, FUEGO P4RL 4-Wire, Horn Strobe, Red P4WL 4-Wire, Horn Strobe, White Wall Strobes SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT L-Series Ordering Information Notes: All -P models have a plain housing (no “FIRE” marking on cover). All -SP models have “FUEGO” marking on cover. All -ALERT models have “ALERT” marking on cover. *Horn-only models are listed for wall or ceiling use. Model Description Horns* HRL*Horn, Red HWL*Horn, White HGRL*Compact Horn, Red HGWL*Compact Horn, White Accessories TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBRL Wall Surface Mount Back Box, Red SBBWL Wall Surface Mount Back Box, White SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, White 4.70" (11.94 cm)1.91" (4.85 cm) 1.25" (3.18 mm) 5.67" (14.4 cm) A0549-00A0550-00 Compact Strobe, Horn Strobe Compact Horn Strobe, Horn Strobe Horn A0548-00 A0547-00 4.7" 119 mm 5.67" 144 mm 1.25" 32 mm 3.46" 88 mm 1.91" 48.5 mm 1.25" 32 mm 5.27" 133.9 mm 3.46" 88 mm 1.25" 32 mm 5.27" 133.9 mm Wall Surface Mount Back Box SBBRL/SBBWL A0554-01 4.82" (12.24 cm)1.85" (4.69 cm) 5.78" (14.68 cm) A0557-00 1.55" (3.9 cm) 3.57" (9.1 cm) 5.38" (13.7 cm) Compact Wall Surface Mount Back Box SBBGRL, SBBGWL Features • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Listed for ceiling mounting only The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Agency Listings 7125-1653:0504 7135-1653:0503 S5512 S4011 FM approved except for ALERT models 3057383 AVDS868-02 • 12/01/2017 • Page 3 AVDS868-02 • 12/01/2017 • Page 2 L-Series Specifications Architect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 × 4 × 1½-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 × 4 × 17⁄8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11 ⁄16 × 4 11 ⁄16 × 2 1 ⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3)8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens)6.8" diameter × 2.5" high (173 mm diameter × 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions (SBBCRL, SBBCWL) 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS868-02 • 12/01/2017 • Page 3 Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 UL Current Draw Data Horn Strobe Tones and Sound Output Data UL Max. Horn Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC DC FWR Candela Range 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 UL Max. Current Draw (mA RMS), Ceiling Horn Strobe, Candela Range (15–177 cd) DC Input 8–17.5 Volts 16–33 Volts 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1K Temporal High 111 164 69 94 147 163 184 229 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 FWR Input 16–33 Volts 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2017 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS868-02 • 12/01/2017 L-Series Dimensions Model Description Ceiling Horn Strobes PC2RL 2-Wire, Horn Strobe, Red PC2WL 2-Wire, Horn Strobe, White PC4RL 4-Wire, Horn Strobe, Red PC4WL 4-Wire, Horn Strobe, White L-Series Ordering Information Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box Model Description Ceiling Strobes SCRL Strobe, Red SCWL Strobe, White SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White 6.83" diam. (173 mm) 2.47" (62.7 mm) 1.37" (34.8 mm)6.92" diam. (175.77 mm) 2.5" (64 mm) 2-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box A0531-01 A0545-00 A0546-00 A0494-01 For a ceiling-listed horn-only device, see AVDS865 “Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications”.