Loading...
20190413 Civil Plans CPR1KILLION ROAD SE (PUBLIC)'B' LOOP SE (PUBLIC)'B' LOOP SE (PUBLIC)'C' ROAD SE (PUBLIC)(PUBLIC) 'A' ROAD SE (PUBLIC) 'B' ROAD SE (PUBLIC) 'D' ROAD SE 'A' ROAD SE (PUBLIC)'A' ROAD SE (PUBLIC)MOUNTAIN VIEW ROAD SE (PUBLIC)(PUBLIC) 'E' ROAD SE 10' DEDICATION 10' UTILITY EASEMENT (TYP.) 10' UTILITY EASEMENT (TYP.) 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH N GRAPHIC SCALE 0 80 160 1" = 80 FEET 40 DATE: July 17, 2018 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-COVR.dwg COVER SHEET C0.1 1 APPROVED FOR CONSTRUCTION BY:DATE: APPROVAL EXPIRES: Director of Public Works SHEET INDEX SHEET NO.SHEET TITLE C0.1 COVER SHEET C1.0 HORIZONTAL CONTROL PLAN C2.0 TESC AND DEMOLITION PLAN C2.1 TESC NOTES AND DETAILS C3.0 OVERALL GRADING PLAN C3.1 ROADWAY SECTIONS AND NOTES C4.0 ROAD 'A' AND ROAD 'D' PLAN AND PROFILE C4.1 ROAD 'A' PLAN AND PROFILE C4.2 ROAD 'A' AND 'E' PLAN AND PROFILE C4.3 'B' LOOP PLAN AND PROFILE C4.4 'B' LOOP PLAN AND PROFILE C4.5 'C' ROAD PLAN AND PROFILE C4.6 INTERSECTION PLANS C4.7 INTERSECTION PLANS C4.8 DRAINAGE PONDS DETAILS C4.9 ROAD NOTES AND DETAILS C4.10 ROAD NOTES AND DETAILS C4.11 STORM DRAINAGE NOTES AND DETAILS C4.12 BAYFILTER DETAILS C6.0 ROAD 'A' AND ROAD 'D' UTILITY PLAN C6.1 ROAD 'A' UTILITY PLAN C6.2 ROAD 'A' AND ROAD 'E' UTILITY PLAN C6.3 'B' LOOP UTILITY PLAN C6.4 'B' LOOP UTILITY PLAN C6.5 'C' ROAD UTILITY PLAN C6.6 WATER SYSTEM MAP C6.7 UTILITY NOTES AND DETAILS C6.8 UTILITY NOTES AND DETAILS C6.9 UTILITY NOTES AND DETAILS C6.10 UTILITY NOTES AND DETAILS C7.0 SIGNING AND LIGHTING PLAN C8.0 MOUNTAIN VIEW ROAD OFFSITE IMPROVEMENTS C8.1 MOUNTAIN VIEW ROAD OFFSITE IMPROVEMENTS C9.0 EXISTING CONDITIONS PER CHICAGO TITLE COMPANY OF WASHINGTON ORDER NO. 180021682 DATED JANUARY 23, 2018 FOR APN 21713430200 AND 21713430300 THE SOUTH HALF OF THE SOUTHWEST QUARTER OF THE SOUTHEAST QUARTER OF SECTION 13, TOWNSHIP 17 NORTH, RANGE 1 EAST, W.M. EXCEPTING THEREFROM PORTION TAKEN FOR KILLION ROAD PER INSTRUMENT RECORDED DECEMBER 7, 2007 UNDER RECORDING NO. 3976226; IN THURSTON COUNTY, WASHINGTON. LEGAL DESCRIPTION NAVD 1988 VERTICAL DATUM ON ORTHOMETRICALLY CORRECTED GPS OBSERVATION USING WSRN AND GEOID 2012A. VERTICAL DATUM NAD 1983 WASHINGTON STATE PLANE SOUTH PROJECTION. BASED ON GPS OBSERVATION USING WSRN AND GEOID 2012A. UNITS OF MEASUREMENTS ARE US SURVEY FEET. BASIS OF BEARING 19.48 ACRESTOTAL SITE GROSS AREA: STORM DRAINAGE:WELLS AND ONSITE RETENTION BASINS ZONING: 21713430200 R-6 21713430300 1.ALL STREETS WILL BE PUBLIC 2.ALL KNOWN WATER SUPPLIES WITHIN 300' OF THE PROJECT BOUNDARY HAVE BEEN IDENTIFIED HERON 3.TRACTS 'A' & 'B' ARE TO BE FOR STORM WATER AND OPEN SPACE, TRACT C TO BE OPEN SPACE FRONT: SIDE SIDE (FLANKING STREET): REAR: 15' 5' MIN EA SIDE, BOTH MUST = 12' 15' 25' SIDE: NET AREA (ROADS) TOTAL NO. OF DWELLING UNITS DENSITY SMALLEST LOT SIZE AVERAGE LOT SIZE OPEN SPACE USE OF TRACTS SEWER (STEP SYSTEM) WATER POWER TELEPHONE CITY OF YELM CITY OF YELM PSE QWEST 118 8.06 AC. NET LENGTH (ROADS)3,767.97 L.F. 'A' - STORMWATER/OPEN SPACE 16,803 S.F. 'B' - STORMWATER/OPEN SPACE 22,942 S.F. 'C' - OPEN SPACE 2,700 S.F. 42,445 S.F. (5% GROSS AREA) 4,050 S.F. 4,356 S.F. 42,445 S.F. 6 UNIT/ACRE NOTES SITE STATISTICS (ACCORDING TO CITY OF YELM) MINIMUM SETBACKS OWNER SITE ADDRESS 9306 SE MOUNTAIN VIEW RD YELM, WA 98597 CIVIL ENGINEER AHBL 2215 NORTH 30TH STREET, SUITE 300 TACOMA, WA 98403 PH. (253) 383-2422 FAX (253) 383-2572 CONTACT: SCOTT KAUL, PE IF WORKERS ENTER ANY TRENCH OR OTHER EXCAVATION FOUR OR MORE FEET IN DEPTH THAT DOES NOT MEET THE OPEN PIT REQUIREMENTS OF WSDOT SECTION 2-09.3(3)B, IT SHALL BE SHORED AND CRIBBED. THE CONTRACTOR ALONE SHALL BE RESPONSIBLE FOR WORKER SAFETY AND AHBL ASSUMES NO RESPONSIBILITY. ALL TRENCH SAFETY SYSTEMS SHALL MEET THE REQUIREMENTS OF THE WASHINGTON INDUSTRIAL SAFETY AND HEALTH ACT, CHAPTER 49.17 RCW. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE APPROXIMATE ONLY AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR ITS REPRESENTATIVE. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK AND AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES THAT HAPPEN DUE TO THE CONTRACTOR'S FAILURE TO LOCATE EXACTLY AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES. AHBL ASSUMES NO LIABILITY FOR THE LOCATION OF UNDERGROUND UTILITIES. FILL MATERIAL SHALL NOT CONTAIN PETROLEUM PRODUCTS, OR SUBSTANCES WHICH ARE HAZARDOUS, DANGEROUS, TOXIC, OR WHICH OTHERWISE VIOLATE ANY STATE, FEDERAL, OR LOCAL LAW, ORDINANCE, CODE, REGULATION, RULE, ORDER, OR STANDARD. UTILITY NOTE FILL SPECIFICATION TRENCH NOTE THE EXISTING CULTURAL AND TOPOGRAPHIC DATA SHOWN ON THESE DRAWINGS HAS BEEN PREPARED, IN PART, BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, AHBL CANNOT ENSURE ACCURACY AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THAT INFORMATION OR FOR ANY ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THESE DRAWINGS AS A RESULT. TOPOGRAPHIC NOTE GEOTECHNICAL SOUTH SOUND GEOTECHNICAL CONSULTING P.O. BOX 39500 LAKEWOOD, WA 98496 CONTACT: TIM ROBERTS PH: (253) 976-0515 SURVEYOR AHBL 2215 NORTH 30TH STREET, SUITE 300 TACOMA, WA 98403 PH. (253) 383-2422 FAX (253) 383-2572 CONTACT: DAVE FOLLANSBEE, PLS UTILITIES PARCEL NUMBERS VICINITY MAP NOT TO SCALE P T FOUND MONUMENT AS NOTED SET NAIL AND WASHER SET REBAR AND CAP FOUND PROPERTY CORNER MAIL BOX SIGN AS NOTED SANITARY SEWER CLEANOUT STORM CATCH BASIN CABLE RISER GAS METER GAS VALVE GUY ANCHOR UTILITY POWER POLE JUNCTION BOX POWER MANHOLE POWER METER LUMINAIRE COMMUNICATIONS MANHOLE TELEPHONE RISER TELEPHONE VAULT BLOW OFF VALVE FIRE HYDRANT IRRIGATION CONTROL VALVE WATER METER POST INDICATOR VALVE WATER VALVE F=FIR M=MAPLE, U=UNKNOWN, CH=CHERRY, P=PLUM POWER VAULT HUB AND TACK STORM LINE WATER LINE GAS LINE ELECTRICAL LINE COMMUNICATION LINE OVERHEAD UTILITIES FENCE LEGEND ASPHALT CONCRETE EXISTING PROPOSED SEWER LINE STORM MANHOLE STEP SEWER LINE SEWER SERVICE BOX PROPOSED MONUMENT SOME INFORMATION CONTAINED WITHIN PLANS ARE FROM PREVIOUSLY APPROVED SKILLINGS CONNOLLY PLANS AND REPORTS. ALL INFORMATION INCORPORATED INTO THESE PLANS HAVE THE APPROVED CONSENT OF SKILLINGS CONNOLLY. NOTE MITCHELL DEVELOPMENT II, LLC 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 CONTACT: PHIL MITCHELL 07/23/2018 Must have 5' setbacks per YMC 80+00 81+00 90+00 91+00 91+57 50+0051+0052+0053+0054+0054+2330+0031+0032+0033+0034+0035+00 36+00 37+00 38+00 3 9 + 0 0 40+0041+0042+0043+009+5510+0011+0012+0013+0014+0015 + 0 0 16+00 17+00 18+00 19+00 20+00 21+00 22+00 23+00 24+00 25+0026+0027+0028+0029+0029+50PROPOSED CONSTRUCTION CENTERLINE PROPOSED R.O.W.ROAD 'A' STA: 26+14.75 =ROAD 'E' STA: 90+00.00ROAD 'A' STA: 22+27.74 = ROAD 'B' STA: 43+11.34 ROAD 'A' STA: 19+12.99 = ROAD 'C' STA: 50+00.00 ROAD 'A' STA: 16+76.99 = ROAD 'B' STA: 30+00.00 ROAD 'B' STA: 36+16.23 = ROAD 'C' STA: 54+23.20 ROAD 'A' STA: 12+40.41 =ROAD 'D' STA: 81+51.34KILLION ROAD'B' LOOP SE'B' LOOP SE'C' ROAD SE'E' ROAD SE 'A' ROAD SE 'B' ROAD SE 'D' ROAD SE 'A' ROAD SE'A' ROAD SEMOUNTAIN VIEW ROADS88° 16' 03"E 182.38'S1° 43' 57"W433.54'S88° 16' 03"E 812.75'N1° 43' 57"E433.89'L=157. 0 8 'R = 1 0 0.00'Δ=8 9 ° 5 9 '5 9" L =1 5 7 .0 8'R =100.00'Δ =9 0°00'01"N1° 43' 57"E342.66'S88° 17' 13"E 350.75'S1° 43' 57"W348.28'L=157.05'R =1 0 0 .0 0 'Δ=89°58'5 0 "L=15 7.1 1' R = 1 0 0.00' Δ = 9 0 ° 0 1 ' 1 0 "N1° 43' 57"E423.20'S88° 16' 03"E 205.10' 28' 28' 30.5'25.5' 25.5'30.5' 25.5'30.5' 30.5'25.5' 30.5' 25.5' 30.5' 25.5' 30.5' 25.5' 30.5'25.5' 25.5'30.5' 30.5' 25.5' 30.5' 25.5' 30.5' 25.5' 28' 28' SITE BOUNDARY N 598246.50 E 1111789.22 307+00308+00309+00310+00311+00312+00313+00314+00N 598283.99 E 1110535.50 20'MOUNTAIN VIEW RD STA: 311+27.78 =ROAD 'D' STA: 80+00.0010' DEDICATION N 597625.35 E 1110513.66 N 597587.39 E 1111768.77 10' DEDICATION PROPOSED 10' UTILITY EASEMENT (TYP.) PROPOSED 10' UTILITY EASEMENT (TYP.) PROPOSED 10' UTILITY EASEMENT (TYP.) BUILDING SETBACK LINE (TYP.) BUILDING SETBACK LINE (TYP.) TRACT A TRACT B TRACT C40' ROW 2,700 S.F.16,805 S.F. 22,942 S.F. 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH N GRAPHIC SCALE 0 50 100 1" = 50 FEET 25 DATE: July 9, 2018 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-CNTRL.dwg HORIZONTAL CONTROL PLAN C1.0 2 INSTALL CAST IN PLACE MONUMENT PER DETAIL 4-16 ON SHEET 15 (18 TYP). CONTRACTOR TO CORE DRILL PAVEMENT AT LOCATIONS PER SURVEYOR DIRECTION. INCLUDED IN COST BID, (SURVEYOR TO SET MONUMENTS N.I.C.) BACKFILL MONUMENT LOCATIONS WITH PEA GRAVEL TO 12" DEPTH PRIOR TO PLACING BALLAST. NOTE 1.THE CONDITIONS OF THE MITIGATED DETERMINATION OF NON-SIGNIFICANCE ARE HEREBY REFERENCED AND ARE CONSIDERED CONDITIONS OF THIS APPROVAL. 2.EACH DWELLING UNIT WITH THE SUBDIVISION SHALL CONNECT TO THE CITY WATER SYSTEM. THE CONNECTION FEE AND METER FEE WILL BE ESTABLISHED AT THE TIME OF BUILDING PERMIT ISSUANCE. ALL CONDITIONS FOR CROSS CONNECTION CONTROL SHALL BE MET, AS REQUIRED IN SECTION 246-290-490 WAC. 3.PRIOR TO FINAL SUBDIVISION APPROVAL, THE DEVELOPER SHALL PAY ANY LATECOMERS ASSESSMENTS APPROVED BY THE CITY COUNCIL BEFORE FINAL SUBDIVISION APPROVAL, INCLUDING THE ASSESSMENT FOR WATER SYSTEM IMPROVEMENTS IN MOUNTAIN VIEW ROAD. 4.EACH DWELLING WITHIN THE SUBDIVISION SHALL CONNECT TO THE CITY S.T.E.P. SEWER SYSTEM. THE CONNECTION FEE AND INSPECTION FEE WILL BE ESTABLISHED AT THE TIME OF BUILDING PERMIT ISSUANCE. 5.PRIOR TO FINAL SUBDIVISION APPROVAL, THE DEVELOPER SHALL PAY ANY LATECOMERS ASSESSMENTS APPROVED BY THE CITY COUNCIL BEFORE FINAL SUBDIVISION APPROVAL, INCLUDING THE ASSESSMENT FOR SEWER SYSTEM IMPROVEMENTS IN MOUNTAIN VIEW ROAD. 6.PRIOR TO CONSTRUCTION, CIVIL ENGINEERING PLANS SHALL BE SUBMITTED TO THE COMMUNITY DEVELOPMENT DEPARTMENT FOR REVIEW AND APPROVAL. CIVIL PLANS SUBMISSION SHALL BE CONSISTENT WITH THE REQUIREMENTS OF THE YELM DEVELOPMENT GUIDELINES AND SHALL INCLUDE DETAILS ON ALL REQUIRED INFRASTRUCTURE. 7.THE CIVIL ENGINEERING PLANS SHALL INCLUDE A FIRE HYDRANT PLAN CONSISTENT WITH THE YELM DEVELOPMENT REGULATIONS WHICH INCLUDES THE PROPOSED LOCATION OF ALL HYDRANTS AND SERVICE LINES AND FIRE FLOW CALCULATIONS FOR ALL EXISTING AND PROPOSED HYDRANTS. THE APPLICANT SHALL BE RESPONSIBLE FOR THE FEE FOR HYDRANT LOCKS ON ALL FIRE HYDRANTS REQUIRED AND INSTALLED AS PART OF DEVELOPMENT. THE APPLICANT SHALL COORDINATE WITH THE YELM PUBLIC WORKS DEPARTMENT TO PURCHASE REQUIRED HYDRANT LOCKS. 8.THE CIVIL ENGINEERING PLANS SHALL INCLUDE A LANDSCAPING PLAN THAT IS CONSISTENT WITH THE CONCEPTUAL LANDSCAPING PLAN BUT THAT IDENTIFIES TYPE I LANDSCAPING ALONG THE SOUTHERN PROPERTY BOUNDARY, TYP II LANDSCAPE BUFFER ALONG THE NORTHERN PROPERTY LINE AND THE FRONTAGES OF KILLION AND MOUNTAIN VIEW ROADS, AND LANDSCAPING APPROPRIATE TO A NEIGHBORHOOD PARK IN THE TWO NORTHERN OPEN SPACE/STORMWATER TRACTS. THE LANDSCAPING PLANS SHALL INCLUDE PLANS FOR IRRIGATION OF ALL PLANTING STRIPS AND REQUIRED LANDSCAPING LOCATED IN ANY OPEN SPACE TRACT AND ALONG MOUNTIAN VIEW AND KILLION ROADS. IRRIGATION PLANS SHALL INCLUDE A SEPARATE WATER METER AND APPROVED BACKFLOW PREVENTION DEVICES. 9.THE APPLICANT SHALL PROVIDE A MINIMUM OF FIVE (5) PERCENT OF THE GROSS LAND AREA AS QUALIFIED OPEN SPACE DEVELOPED AS PARKS. THE FINAL LANDSCAPE PLANS SHALL INCLUDE PLANS TO CREATE NEIGHBORHOOD PARKS WITHIN THE TWO NORTHERN OPEN SPACE TRACTS WHICH INCLUDE A MIX OF ELEMENTS TYPICALLY FOUND IN AN IMPROVED PARK AREA SUCH AS PLAY EQUIPMENT, ATHLETIC COURTS, AND PICNIC FACILITIES. 10.THE CIVIL ENGINEERING PLANS SHALL INCLUDE PLANS FOR THE COLLECTION, TREATMENT, AND INFILTRATION OF STORMWATER IN ACCORDANCE WITH THE 2014 ECOLOGY STORMWATER MANUAL, AS ADOPTED BY THE CITY OF YELM. BEST MANAGEMENT PRACTICES (BMP'S) ARE REQUIRED DURING CONSTRUCTION. A 10-FOOT SETBACK FROM ALL PROPERTY LINES AND EASEMENTS ARE REQUIRED FOR STORMWATER FACILITIES. THE FINAL STORMWATER PLAN SHALL INCLUDE AN OPERATION AND MAINTENANCE PLAN. THE STORMWATER SYSTEM SHALL BE HELD IN COMMON BY THE HOMEOWNERS ASSOCIATION AND THE HOMEOWNERS AGREEMENT SHALL INCLUDE PROVISIONS FOR THE ASSESSMENT OF FEES AGAINST INDIVIDUAL LOTS FOR THE MAINTENANCE AND REPAIR OF THE STORMWATER FACILITIES. ALL ROOF DRAIN RUNOFF SHALL BE INFILTRATED ON EACH LOT UTILIZING INDIVIDUAL DRYWELLS. PROJECT CONDITIONS OF APPROVAL 09/16/2019 80+00 81+00 90+00 91+00 91+57 50+0051+0052+0053+0054+0054+2330+0031+0032+0033+0034+0035+00 36+00 37+00 38+00 3 9 + 0 0 40+0041+0042+0043+009+5510+0011+0012+0013+0014+0015 + 0 0 16+00 17+00 18+00 19+00 20+00 21+00 22+00 23+00 24+00 25+0026+0027+0028+0029+0029+50KILLION ROAD'B' LOOP SE'B' LOOP SE'C' ROAD SE'E' ROAD SE 'A' ROAD SE 'B' LOOP SE 'D' ROAD SE 'A' ROAD SE'A' ROAD SEMOUNTAIN VIEW ROAD306+00307+00308+00309+00310+00311+00312+00313+00314+00315+00XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 7 1 7 4 2 6 4 A A B B8 5 90' 60' 60' 40' 2 3 3 SAWCUT LINE ALONG ROW LINE (TYP.) REMOVE EXISTING ASPHALT CONCRETE PAVEMENT WITHIN ROW (TYP.) PROTECT EXISTING ASPHALT CONCRETE PAVEMENT OUTSIDE OF ROW (TYP.) REMOVE EXISTING ASPHALT CONCRETE PAVEMENT WITHIN ROW (TYP.) REMOVE EXISTING ASPHALT CONCRETE PAVEMENT WITHIN PROPERTY LIMITS (TYP.) PROTECT EXISTING SIDEWALK STA:307+45.13, 15.75'LT END CURB REMOVAL 299+98 300+00 301+00302+00303+00304+00305+00 "STOP"SAWCUT LINE ALONG ROW LINE (TYP.) SAWCUT LINE REMOVE EXISTING ASPHALT CONCRETE PAVEMENT WITHIN ROW (TYP.) REMOVE EXISTING CEMENT CONCRETE PAVEMENT WITHIN ROW (TYP.) PROTECT EXISTING ASPHALT CONCRETE PAVEMENT OUTSIDE OF ROW (TYP.) STA:304+82.72, 15.99'LT BEGIN CURB REMOVAL 316+00 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH N GRAPHIC SCALE 0 50 100 1" = 50 FEET 25 DATE: July 6, 2018 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-TESC.dwg TESC AND DEMOLITION PLAN C2.0 3 TESC KEYNOTES INSTALL CONSTRUCTION ENTRANCE INSTALL FILTER FABRIC FENCE INSTALL INLET SEDIMENT PROTECTION REMOVE EXISTING FENCE REMOVE EXISTING UNUSED UTILITY POLE INSTALL 34" TEMPORARY TYPE III BARRICADE CONSTRUCT TEMPORARY CONVEYANCE DITCH AS REQUIRED, COORDINATE WITH CESCL TEMPORARY INFILTRATION BASIN 60' x 90' x 5' DEEP BOTTOM ELEVATION: 330.00 TEMPORARY INFILTRATION BASIN 40' x 60' x 5' DEEP BOTTOM ELEVATION: 334.00 1 2 3 4 5 6 7 8 9 ±60' ELEV=±331 ELEV=±336 3: 1 3:1 SECTION A-A NOT TO SCALE 2 C2.1 1 C2.1 3 C2.1 DEMOLITION LEGEND: DEMOLISH EXISTING ASPHALT CONCRETE PAVEMENT DEMOLISH EXISTING CEMENT CONCRETE PAVEMENT SAWCUT LINE NOTES SEE NOTES AND DETAILS PER SHEET C2.1±40' ELEV=±335 ELEV=±340 3: 1 3:1 SECTION B-B NOT TO SCALE CONTRACTOR TO STABILIZE ALL DISTURBED PORTIONS OF THE SITE USING SEED, MULCH, OR OTHER ENGINEER APPROVED BMP IN ACCORDANCE WITH SWMM.MATCHLINE AMATCHLINE A MATCHLINE BMATCHLINE B NN09/16/2019 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH DATE: July 6, 2018 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-TESC.dwg TESC NOTES AND DETAILS C2.1 4 NOTES: 1.FILTERS SHALL BE i NSPECTED AFTER EACH STORM EVENT AND CLEANED OR REPLACED WHEN 1/3 FULL. 2.INSTALL INLET PROTECTION IN ALL NEW STORM STRUCTURES THAT WILL COLLECT STORMWATER AS THEY ARE INSTALLED. ADAPTOR SKIRT RETRIEVAL STRAP OVERFLOW (TO BYPASS PEAK STORM VOLUMES) EXISTING CATCH BASIN SEDIMENT ACCUMULATION GEOTEXTILE FABRIC 24"36"48" 4"-8" QUARRY SPALLS GEOTEXTILE 12" MIN. THICKNESS EXIST I N G R O A D R = 25' MIN. INGRESS/EGRESS AREA PROVIDE FULL WIDTH OF 20' MI N. RUNOFF DRAINS OFF THE PAD ENTRANCE BE CROWNED SO THAT IT IS RECOMMENDED THAT THE100' 1.QUARRY SPALLS (OR HOG FUEL) SHALL BE ADDED IF THE PAD IS NO LONGER IN ACCORDANCE WITH THE SPECIFICATIONS. 2.IF THE ENTRANCE IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT, THEN ALTERNATIVE MEASURES TO KEEP THE STREETS FREE OF SEDIMENT SHALL BE USED. THIS MAY INCLUDE STREET SWEEPING, AN INCREASE IN THE DIMENSIONS OF THE ENTRANCE, OR THE INSTALLATION OF A WHEEL WASH. IF WASHING IS USED, IT SHALL BE DONE ON AN AREA COVERED WITH CRUSHED ROCK, AND WASH WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND. 3.ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING. THE SEDIMENT COLLECTED BY SWEEPING SHALL BE REMOVED OR STABILIZED ON-SITE. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DOWN THE STREET, EXCEPT WHEN SWEEPING IS INEFFECTIVE AND THERE IS A THREAT TO PUBLIC SAFETY. IF IT IS NECESSARY TO WASH THE STREETS, THE CONSTRUCTION OF A SMALL SUMP SHALL BE CONSIDERED. THE SEDIMENT WOULD THEN BE WASHED INTO THE SUMP. 4.ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAD AND END UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY. 5.IF VEHICLES ARE ENTERING OR EXITING THE SITE AT POINTS OTHER THAN THE CONSTRUCTION ENTRANCE(S), FENCING SHALL BE INSTALLED TO CONTROL TRAFFIC. MAINTENANCE STANDARDS PROVIDE DIP CULVERT FOR TEMPORARY CONTROL OF DRAINAGE. 1.THE FILTER FABRIC SHALL BE PURCHASED IN A CONTINUOUS ROLL CUT TO THE LENGTH OF THE BARRIER TO AVOID USE OF JOINTS. WHEN JOINTS ARE NECESSARY, FILTER CLOTH SHALL BE SPLICED TOGETHER ONLY AT A SUPPORT POST WITH A MINIMUM SIX-INCH OVERLAP, AND BOTH ENDS SECURELY FASTENED TO THE POST. 2.THE FILTER FABRIC FENCE SHALL BE INSTALLED TO FOLLOW THE CONTOURS (WHERE FEASIBLE). THE FENCE POSTS SHALL BE SPACED A MAXIMUM OF SIX FEET APART AND DRIVEN SECURELY INTO THE GROUND (MINIMUM OF 30") 3.A TRENCH SHALL BE EXCAVATED, ROUGHLY EIGHT INCHES WIDE AND TWELVE INCHES DEEP, UPSLOPE AND ADJACENT TO THE WOOD POST TO ALLOW THE FILTER FABRIC TO BE BURIED. 4.WHEN STANDARD STRENGTH FILTER FABRIC IS USED, A WIRE MESH SUPPORT FENCE SHALL BE FASTENED SECURELY TO THE UPSLOPE SIDE OF THE POSTS USING HEAVY-DUTY WIRE STAPLES AT LEAST ONE INCH LONG, TIE WIRES, OR HOG RINGS. THE WIRE SHALL EXTEND INTO THE TRENCH A MINIMUM OF FOUR INCHES AND SHALL NOT EXTEND MORE THAN THIRTY SIX INCHES ABOVE THE ORIGINAL GROUND SURFACE. 5.THE STANDARD STRENGTH FILTER FABRIC SHALL BE STAPLED OR WIRED TO THE FENCE, AND TWENTY INCHES OF THE FABRIC SHALL BE EXTENDED INTO THE TRENCH. THE FABRIC SHALL NOT EXTEND MORE THAN THIRTY SIX INCHES ABOVE THE ORIGINAL GROUND SURFACE. FILTER FABRIC SHALL NOT BE STAPLED TO EXISTING TREES. 6.WHEN EXTRA-STRENGTH FILTER FABRIC AND CLOSER POST SPACING ARE USED, THE WIRE MESH SUPPORT FENCE MAY BE ELIMINATED. IN SUCH A CASE, THE FILTER FABRIC IS STAPLED OR WIRED DIRECTLY TO THE POSTS WITH ALL OTHER PROVISIONS OF STANDARD NOTE (S) APPLYING. 7.THE TRENCH SHALL BE BACKFILL WITH 3/4 INCH MINIMUM DIAMETER WASHED GRAVEL. 8.FILTER FABRIC FENCES SHALL BE REMOVED WHEN THEY HAVE SERVED THEIR USEFUL PURPOSE, BUT NOT BEFORE THE UPSLOPE AREA HAS BEEN PERMANENTLY STABILIZED. 9.FILTER FABRIC FENCES SHALL BE INSPECTED IMMEDIATELY AFTER EACH RAINFALL AND AT LEAST DAILY DURING PROLONGED RAINFALL. ANY REQUIRED REPAIRS SHALL BE MADE IMMEDIATELY. 10.CONTRIBUTING LENGTH TO FENCE SHALL NOT BE MORE THAN 100 FEET. 11.DO NOT INSTALL BELOW AN OUTLET PIPE OR WEIR. 12.DO NOT DRIVE OVER OR FILL OVER FILTER FABRIC FENCE. SIDE VIEW NOTES: FRONT VIEW CHAINLINK FENCE 8" 2.0' MIN.5.0'1.0'2.0'0.5'6' MAX. 5.0' 2.0' 2.5' 2" X 4" WOOD POSTS, STANDARD OR BETTER, OR STEEL FENCE POST BURY BOTTOM OF FILTER MATERIAL IN 8"X12" TRENCH 2" X 4" BY 14 GA. WIRE FABRIC OR EQUIVALENT EXISTING GRADE ORANGE FILTER FABRIC MATERIAL 60" WIDE ROLLS - USE RINGS TO ATTACH ATTACH TO WIRE FABRIC 2" X 4" WOOD POST OR STEEL FENCE POST PROVIDE 3/4" - 1 1/2" WASHED GRAVEL BACKFILL IN TRENCH AND ON BOTH SIDES OF FILTER FENCE FABRIC ON THE SURFACE 2" X 2" BY 14 GA. WIRE FABRIC OR EQUIVALENT, AFFIX TO POST FILTER FABRIC MATERIAL MIRAFI 100 NS OR EQUIVALENT CONSTRUCTION NOTES 5. 4. 3. 2. UTILITIES INSPECTOR PRIOR TO CONSTRUCTION. SHALL SECURE THE NECESSARY PERMITS FROM THE YELM CONSTRUCTED IN THE YELM RIGHT-OF-WAY, THE APPLICANT IF WATER OR OTHER UTILITIES ARE REQUIRED TO BE BE IN ATTENDANCE. THE DEVELOPER AND HIS/HER CONTRACTOR(S) MUST YELM'S DEVELOPMENT AND UTILITIES INSPECTOR. PRECONSTRUCTION CONFERENCE SHALL BE SCHEDULED WITH OR IMPROVEMENTS TO EXISTING ROADWAY FACILITIES, A PRIOR TO ANY ON SITE IMPROVEMENTS, ROADWAY CONSTRUCTION, CONSTRUCTED FACILITIES OR ADJACENT PROPERTIES. UNDERTAKEN DURING CONSTRUCTION TO AVOID DAMAGE TO TEMPORARY EROSION AND SEDIMENTATION CONTROL SHALL BE IS RESPONSIBLE FOR SCHEDULING THIS WORK. QUALIFIED LICENSED SURVEYOR. THE DEVELOPER OR CONTRACTOR CONSTRUCTION STAKING SHALL BE BY THE DESIGN ENGINEER OR A CONSTRUCTION USE BY THE ENGINEER. RESPECTS, INCLUDING SAND EQUIVALENT, WILL BE APPROVED FOR NATIVE MATERIALS MEETING THE SPECIFICATIONS IN ALL ASSOCIATION, AND CITY OF YELM PUBLIC WORKS STANDARDS. AND WASHINGTON STATE CHAPTER, AMERICAN PUBLIC WORKS JOINTLY BY WASHINGTON STATE DEPARTMENT OF TRANSPORTATION FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION, PUBLISHED MOST CURRENT STANDARD SPECIFICATIONS FOR ROAD SPECIFICATIONS WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH THE1. A SILT SOCK SHALL BE INSTALLED AT EACH CATCH BASIN LOCATION.6. SEDIMENTS OR BUILD A NEW FENCE PARALLEL TO THE OLD ONE. WHEN SEDIMENT BUILDUP BECOMES EXCESSIVE, REMOVE THE AND DAILY DURING PROLONGED RAIN AND REPAIR THEM AS NECESSARY. POSSIBLE. INSPECT FILTER FABRIC FENCES AFTER EACH RUNOFF EVENT STORM WATER DISCHARGED OFF SITE IS AS FREE OF SEDIMENT AS 9. FILTER FABRIC FENCES SHALL BE MAINTAINED IN ORDER THAT DURING CONSTRUCTION AND SHALL WATER DOWN AREAS AS NECESSARY 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DUST CONTROL ON SITE AND IN CONFORMANCE WITH THE PERTINENT CITY OF YELM ORDINANCES. STABILIZED BY SEEDING AND MULCHING. UNWORKED REGULARLY OR FOR AN EXTENDED TIME SHALL BE DISTURBED AREAS GREATER THAN 5,000 S.F. THAT ARE LEFT 5. DURING THE TIME PERIOD OF NOVEMBER 1 THROUGH APRIL 30, ALL 6. STOCKPILED DIRT MATERIAL SHALL BE COVERED. BY THE COUNTY. THROUGHOUT DURATION OF PROJECT CONSTRUCTION AS DIRECTED 4. CONTRACTOR SHALL MAINTAIN ALL EROSION CONTROL DEVICES ROCK ACCESS DRIVEWAY SHALL BE IN PLACE, AS SHOWN ON PLAN. 3. PRIOR TO ANY OTHER WORK ON SITE, EROSION CONTROL FENCING AND CITY OF YELM OR OTHER GOVERNING AUTHORITY OR AGENCY. 2. COMPLY WITH ALL OTHER PERMITS AND OTHER REQUIREMENTS BY FOLLOWING COMPLETION OF CONSTRUCTION. SHALL BE CLEANED OF ALL SILTS, SAND AND OTHER MATERIALS WATER POLLUTION/FLOOD ACTIVITIES AND CONVEYANCE SYSTEMS USED AS PART OF THE TEMPORARY EROSION CONTROL AND B. ALL PERMANENT STORAGE AND DETENTION AREAS MANUAL. REQUIREMENTS OF TABLE 9.1 OF THE THURSTON REGION DRAINAGE 8. ALL DISTURBED AREAS SHALL BE SEEDED PER THE STABILIZATION PRECLUDE ANY CONSTRUCTION ACTIVITY ON THE SITE. SUBMITTAL AND APPROVAL OF THESE PLANS SHALL SHALL BE SUBMITTED TO AND APPROVED BY THE COUNTY. A. SOIL EROSION AND WATER POLLUTION/FLOOD CONTROL PLANS SPECIFICATIONS AND AS FOLLOWS: REQUIRED IN ACCORDANCE WITH SECTION 1-07.15 OF THE STANDARD 1. TEMPORARY EROSION/WATER POLLUTION MEASURES SHALL BE DRAINAGE, GRADING AND OTHER TREATMENT. CONTRACTOR, BUT MUST BE AUGMENTED WITH MULCH, NETTING, OR HOWEVER, WHENEVER IT IS IN THE INTEREST OF THE APPLICANT/ APRIL THROUGH SEPTEMBER, INCLUSIVE. SEEDING MAY PROCEED, SEEDING ALONE WILL BE ACCEPTABLE ONLY DURING THE MONTHS OF TREATMENT APPLICABLE TO THE TIME OF YEAR IN QUESTION. GRASS MULCHING, GRASS PLANTING OR OTHER APPROVED EROSION CONTROL MORE, ALL DISTURBED AREAS MUST BE IMMEDIATELY STABILIZED WITH NO FURTHER WORK IS ANTICIPATED FOR A PERIOD OF 30 DAYS OR 16. IN ANY AREA WHICH HAS BEEN STRIPPED OF VEGETATION AND WHERE AND/OR STORM DRAINAGE SYSTEMS. ADJACENT PROPERTIES, SENSITIVE AREAS, NATURAL WATER COURSES SHALL INSTALL ADDITIONAL FACILITIES AS NECESSARY TO PROTECT CONTROL EROSION AND SEDIMENTATION, THE APPLICANT/CONTRACTOR MEASURES AS SHOWN ON THIS DRAWING NOT PROVE ADEQUATE TO 15. SHOULD THE TEMPORARY EROSION AND SEDIMENTATION CONTROL SATISFIED. CONTINUE UNTIL SUCH TIME AS THE AFFECTED PROPERTY OWNER IS COMMENCE RESTORATION METHODS. RESTORATION ACTIVITY WILL MUST CEASE, AND THE OWNER/CONTRACTOR WILL IMMEDIATELY DEVELOPMENT THAT WILL AGGRAVATE THE SITUATION IN THE FUTURE PROPERTY OWNERS, ALL CONSTRUCTION WORK WITHIN THE 14. IN CASE EROSION OR SEDIMENTATION OCCURS TO ADJACENT IN A FIELD BY A SOILS ENGINEER OR ENGINEERING GEOLOGIST. NATIVE SOILS. HEIGHT AND WIDTH OF THE BENCH WILL BE DETERMINED (HORIZONTAL TO VERTICAL) SHALL BE BENCHED AS DIRECTED INTO 13. PLACEMENT OF FILL SECTIONS ON SLOPES GREATER THAN 4:1 BACKFILL SHALL BE COMPACTED AS SPECIFIED ABOVE. DENSITY BEFORE PLACING THE NEXT LIFT. ALL UTILITY TRENCH MOISTURE CONTENT, AND COMPACTED TO THE SPECIFIED MINIMUM EIGHT INCHES LOOSE THICKNESS, CONDITIONED TO THE OPTIMUM 12. ALL FILL SHALL BE PLACED IN UNIFORM HORIZONTAL LIFTS OF SIX TO CONSULTANT FOR USE. SUBSTITUTED WITH PRIOR APPROVAL BY A GEOTECHNICAL ANSI/ASTM D-1140 TEST PROCEDURE. OTHER MATERIAL MAY BE MORE THAN 7% BY WEIGHT SHALL PASS THE #200 SCREEN AS TESTED BY DETERMINED BY ANSI/ASTM TEST METHOD D-2487) SHALL BE USED. NO GRADED GRAVEL OR GRAVELY SAND (CLASSIFYING AS GW OR SW AS 11. FOR IMPORTED STRUCTURAL FILL A CLEAN, SIX-INCH MINUS, WELL CONTROL FACILITIES ONLY WHEN THE ENTIRE SITE IS STABILIZED. 17. REMOVE ALL REMAINING TEMPORARY EROSION AND SEDIMENTATION TEMPORARY EROSION CONTROL NOTES IN AREAS UNDER STRUCTURES, PAVING SECTIONS, SIDEWALKS, AND OTHER AREAS TO BE GRADED, STRIP ALL TOPSOIL AND ORGANIC MATERIAL. STOCKPILE AND COVER WITH PLASTIC ALL STOCKPILED TOPSOIL. ALL TOPSOIL AND SOD NOT TO BE REUSED SHALL BE REMOVED FROM SITE AND DISPOSED OF PROPERLY AT THE CONTRACTORS EXPENSE. FOR STRUCTURAL FILL IN AREAS UNDER FOOTINGS AND SLABS ON GRADE, ALL SOILS SHALL BE COMPACTED TO A MINIMUM DENSITY OF 90% OF ASTM D-1557 OR 95% OF UBC 70-1. THIS INCLUDES PROOF-ROLLING NATIVE SOILS EXPOSED IN THE BOTTOM OF THE EXCAVATION PRIOR TO PLACEMENT OF FILL. MATERIALS UNDER THE PAVING SECTION SHALL ALSO BE COMPACTED TO THE MINIMUM DENSITY BY PROOF-ROLLING PRIOR TO PLACEMENT OF THE PAVING SECTION; THIS INCLUDES PROOF-ROLLING IN-PLACE SOILS, SOILS THAT HAVE BEEN DISTURBED DURING CONSTRUCTION AND ALL STRUCTURAL FILL MATERIALS. 10. 1 NOT TO SCALE FILTER FABRIC FENCE 2 NOT TO SCALE INLET SEDIMENT PROTECTION 3 NOT TO SCALE CONSTRUCTION ENTRANCE GENERAL NOTES 1.DEMOLITION: IT IS THE CONTRACTOR'S RESPONSIBILITY TO FULLY REVIEW THE SITE CONDITIONS AND TO CORRELATE THESE OBSERVATIONS WITH THE PROJECT WORK AND INCLUDE ALL NECESSARY DEMOLITION, WHETHER SHOWN OR NOT, AND INCLUDE ALL SUCH COSTS IN THE SCOPE OF WORK. 2.CLEARING: IT IS THE INTENT OF THE WORK UNDER THIS CONTRACT TO CONDUCT ALL CLEARING NECESSARY TO BE ABLE TO COMPLETE ALL THE WORK OF THIS PROJECT. 3.CONTRACTOR SHALL LEGALLY DISPOSE OFF THE OWNER'S PROPERTY, ALL DEMOLISHED AND REMOVED MATERIALS. 4.STRIPPINGS MAY BE STOCKPILED FOR USE IN LANDSCAPE AREAS. ALL EXCESS STRIPPINGS SHALL BE DISPOSED OFF OWNER'S PROPERTY. 5.IF SEDIMENT REACHES CATCH BASINS ADD INLET PROTECTION IN ACCORDANCE WITH SWMM. 1.STOCKPILES SHALL BE STABILIZED (WITH PLASTIC COVERING OR OTHER APPROVED DEVICE) DAILY BETWEEN NOVEMBER 1 AND MARCH 31. 2.IN ANY SEASON, SEDIMENT LEACHING FROM STOCK PILES MUST BE PREVENTED. 3.TOPSOIL SHALL NOT BE PLACED WHILE IN A FROZEN OR MUDDY CONDITION, WHEN THE SUBGRADE IS EXCESSIVELY WET, OR WHEN CONDITIONS EXIST THAT MAY OTHERWISE BE DETRIMENTAL TO PROPER GRADING OR PROPOSED SODDING OR SEEDING. 4.PREVIOUSLY ESTABLISHED GRADES ON THE AREAS TO BE TOPSOILED SHALL BE MAINTAINED ACCORDING TO THE APPROVED PLAN. 1.MULCH MATERIALS USED SHALL BE HAY OR STRAW, AND SHALL BE APPLIED AT THE RATE OF 2 TONS/ACRE. (MIN. 2" THICK) 2.MULCHES SHALL BE APPLIED IN ALL AREAS WITH EXPOSED SLOPES GREATER THAN 2:1. 3.MULCHING SHALL BE USED IMMEDIATELY AFTER SEEDING OR IN AREAS WHICH CANNOT BE SEEDED BECAUSE OF THE SEASON. 4.ALL AREAS NEEDING MULCH SHALL BE COVERED BY NOVEMBER 1. 1.PLASTIC SHEETING SHALL HAVE A MINIMUM THICKNESS OF 6 MILS AND SHALL MEET THE REQUIREMENTS OF THE STATE STANDARD SPECIFICATIONS SECTION 9-14.5. 2.COVERING SHALL BE INSTALLED AND MAINTAINED TIGHTLY IN PLACE BY USING SANDBAGS OR TIRES ON ROPES WITH A MAXIMUM 10-FOOT GRID SPACING IN ALL DIRECTIONS. ALL SEAMS SHALL BE TAPED OR WEIGHTED DOWN FULL LENGTH AND THERE SHALL BE AT LEAST A 12 INCH OVERLAP OF ALL SEAMS. 3.CLEAR PLASTIC COVERING SHALL BE INSTALLED IMMEDIATELY ON AREAS SEEDED BETWEEN NOVEMBER 1 AND MARCH 31 AND REMAIN UNTIL VEGETATION IS FIRMLY ESTABLISHED. 4.WHEN THE COVERING IS USED ON UN-SEEDED SLOPES, IT SHALL BE KEPT IN PLACE UNTIL THE NEXT SEEDING PERIOD. 5.PLASTIC COVERING SHEET SHALL BE BURIED TWO FEET AT THE TOP OF SLOPES IN ORDER TO PREVENT SURFACE WATER FLOW BENEATH SHEETS. 6.PROPER MAINTENANCE INCLUDES REGULAR CHECKS FOR RIPS AND DISLODGED ENDS. PLASTIC COVERING NOTES: 1.CONTRACTOR SHALL OBTAIN NPDES PERMIT AND SHALL DESIGNATE A WASHINGTON STATE CERTIFIED EROSION AND SEDIMENT CONTROL LEAD WHO SHALL HAVE THE RESPONSIBILITY TO MONITOR AND IMPLEMENT EROSION CONTROL MEASURES. 2.CONTRACTOR SHALL PROVIDE AN EROSION AND SEDIMENT CONTROL LEAD (ESCL) WHO WILL BE ON-SITE OR ON CALL AT ALL TIMES. THE EROSION CONTROL LEAD SHALL HAVE THE AUTHORITY TO IMPLEMENT THE STORMWATER POLLUTION PREVENTION PLAN BASED ON SITE CONDITIONS WITHIN THEIR SCOPE. IF THE METHODS INDICATED FOR EROSION AND SEDIMENT CONTROL ARE NOT ADEQUATE, THE ESCL SHALL IMPLEMENT ADDITIONAL METHODS AS REQUIRED. 3.CONTRACTOR SHALL PREPARE A CONSTRUCTION SWPPP FOR THIS PROJECT. REFER TO THE PROJECT MANUAL FOR A SAMPLE SWPPP FOR THIS PROJECT. RETAIN A COPY OF THE SWPPP ON-SITE AT ALL TIMES AND AVAILABLE TO THE JURISDICTIONS HAVING AUTHORITY. 4.CONTRACTOR TO COORDINATE AREAS FOR LAY DOWN, STOCK PILE, TRAILERS & PARKING WITH WMD CONSTRUCTION PROJECT MANAGER BRAD OLSON. 5.CONTRACTOR TO REMOVE CONSTRUCTION DEBRIS, MUD, ROCKS, DIRT, ETC FROM EXISTING ROAD AND PARKING LOT DAILY. MULCHING NOTES TESC/SWPPP NOTES SOIL STOCKPILE NOTES 09/16/2019 80+00 81+00 90+00 91+00 91+57 54+23 50+0051+0052+0053+0054+0030+0031+0032+0033+00 34+0035+00 36+00 37+00 38+00 39+00 40+0041+00 42+0043+0029+50 9+55 10+0011+0012+0013+00 14+0015 + 0 0 16+00 17+00 18+00 19+00 20+00 21+00 22+00 23+00 24+00 25+00 26+0027+00 28+00 29+00KILLION ROAD'B' LOOP SE'B' LOOP SE'C' ROAD SE'E' ROAD SE 'A' ROAD SE 'B' ROAD SE 'D' ROAD SE 'A' ROAD SE'A' ROAD SEMOUNTAIN VIEW ROAD307+00308+00309+00310+00311+00312+00313+00314+00315+00PROPERTY LINE IS LIMIT OF CLEARING AND GRADING WEST EDGE OF PAVEMENT IS LIMIT OF CLEARING AND GRADING EXISTING CONTOUR (TYP.)CONTOURS WITHIN PROPOSED ROW ARE TO FINISHED GRADE. SEE PAVEMENT SECTIONS ON SHEET C3.1 FOR DEPTH TO SUBGRADE PROPERTY LINE IS LIMIT OF CLEARING AND GRADING 3403 3 7 3 3 8 3 3 9 3403403453 3 7 337338338339339341341342 3423 4 3 343344346347348335336337338344340337338339341 342 342 343 343 335340336337338339341348 340 339341342343 2:1 MAX SLOPE (TYPICAL) 3 4 2 3 4 3 342 34 0 3 3 7 33 8 33 9 3 4 1 342343344344343NO GRADING OUTSIDE ROW 3 4 5 3413423 4 3 3 4 4 34634034 53413 4 2 34 3 34 4 3 4 6 335336 337 338 339 340339341342341 342 343 343344340339341342343340337338339341341 3 4 2 3 4 3 34 4 3 4 2 3 4 3 34 4 340341342343346347348349346345344343342341343 344 344343343 34 9 348347349343339336 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH N GRAPHIC SCALE 0 50 100 1" = 50 FEET 25 DATE: July 6, 2018 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-ROUGH-GRAD.dwg OVERALL GRADING PLAN C3.0 5 CUT: 26,500 CY FILL: 23,500 CY NET: 3,000 CY (CUT) NOTE: THE ABOVE QUANTITIES ARE ESTIMATES ONLY INTENDED FOR THE PERMITTING PROCESS. DO NOT USE FOR BID PURPOSES. THE QUANTITIES DO NOT HAVE STRIPPING, COMPACTION, OR CUT OR FILL ADJUSTMENT FACTORS APPLIED TO THEM. EARTHWORK QUANTITIES 09/16/2019 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH DATE: July 5, 2019 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-ROAD SECTIONS.dwg ROADWAY SECTIONS AND NOTES C3.1 6 1.ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH CITY OF YELM STANDARDS, AND THE MOST CURRENT COPY OF THE STATE OF WASHINGTON STANDARD SPECIFICATIONS FOR ROAD, BRIDGE, AND MUNICIPAL CONSTRUCTION. 2.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TRAFFIC CONTROL IN ACCORDANCE WITH MUTCD. PRIOR TO DISRUPTION OF ANY TRAFFIC, TRAFFIC CONTROL PLANS SHALL BE PREPARED AND SUBMITTED TO THE CITY FOR APPROVAL. NO WORK SHALL COMMENCE UNTIL ALL APPROVED TRAFFIC CONTROL IS IN PLACE. 3.ALL CURB AND GUTTER, STREET GRADES, SIDEWALK GRADES, AND ANY OTHER VERTICAL AND/OR HORIZONTAL ALIGNMENT SHALL BE STAKED BY AN ENGINEERING OR SURVEYING FIRM CAPABLE OF PERFORMING SUCH WORK. 4.WHERE NEW ASPHALT JOINS EXISTING, THE EXISTING ASPHALT SHALL BE CUT TO A NEAT VERTICAL EDGE AND TACKED WITH ASPHALT EMULSION TYPE CSS-1 IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS. THE NEW ASPHALT SHALL BE FEATHERED BACK OVER EXISTING TO PROVIDE FOR A SEAL AT THE SAW CUT LOCATION AND THE JOINT SEALED WITH GRADE AR-4000W PAVING ASPHALT. 5.COMPACTION OF SUBGRADE, ROCK, AND ASPHALT SHALL BE IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS. 6.SUBGRADE INSPECTION SHALL BE PERFORMED BY AN APPROVED TESTING FIRM AND FORMS SHALL BE INSPECTED FOR LINE AND GRADE BY AN ENGINEER BEFORE POURING CONCRETE. 7.CERTIFICATION AS TO CONFORMANCE SHALL BE PROVIDED TO THE CITY PRIOR TO ACCEPTANCE OF WORK. 8.THE CONTRACTOR/DEVELOPER SHALL FURNISH AND INSTALL ALL PERMANENT SIGNING. 9.CONTRACTOR TO COORDINATE WITH CITY AND OWNER TO USE EXISTING ONSITE SUITABLE GROUND BASE IN LIEU OF IMPORT GRAVEL BASE. 17' 0.5' 6'5' 0.25' HMA CI. 1/2" PG 64-22 0.17' CSTC 0.67' GRAVEL BASE COMPACTED SUBGRADE LANDSCAPING 2%2% CL PROFILE GRADE 2% CONSTRUCT CEMENT CONCRETE BARRIER CURB AND GUTTER PER DETAIL 4-13 SEE SHEET C4.9 (TYP) 28' ROW SIDEWALK 0.5' 6'5' LANDSCAPING 2% 28' ROWROW SIDEWALK 17'ROWCONSTRUCT SIDEWALK PER DETAIL 4-11 SEE SHEET C4.9 (TYP) CONSTRUCTION CL = CL OF ROW 16' 0.5' 7'5' 0.25' HMA CI. 1/2" PG 64-22 0.17' CSTC 0.67' GRAVEL BASE COMPACTED SUBGRADE LANDSCAPING 2%2% CL PROFILE GRADE 2% CONSTRUCT CEMENT CONCRETE BARRIER CURB AND GUTTER PER DETAIL 4-13 SEE SHEET C4.9 (TYP) 20' EX ROW 10' DEDICATION'EX ROW±5.5'±21.7' EX EP EX EPFENCE EX ±2' EX ROADWAY PAVEMENT SIDEWALK 0.5' FUTURE 7'FUTURE 5' LANDSCAPING 20' EX ROWFUTURE 8'EX ROWFUTURE ROWSIDEWALK DEDICATION CONSTRUCT SIDEWALK PER DETAIL 4-11 SEE SHEET C4.9 (TYP) CONSTRUCTION CL (NOT CL OF ROW) 16' 4.0'ROWNOT TO SCALE N.I.C.N.I.C. 14'14'3'3' LANDSCAPE ISLAND 2'FLOW LINEFLOW LINEFLOW LINEFLOW LINECONSTRUCT CEMENT CONCRETE BARRIER CURB PER DETAIL 4-13 SEE SHT C4.9 (TYP) (SEE PLAN FOR LOCATION) 2%2% 2% 2%2% TO BE REMOVED NOTE: EXISTING PAVEMENT TO BE REMOVED WITHIN ROW LIMITS NOTE: EXISTING PAVEMENT TO BE REMOVED WITHIN ROW LIMITS 18.5' 1' 6'5' 0.17' HMA CI. 1/2" PG 64-22 0.17' CSTC 0.67' GRAVEL BASE COMPACTED SUBGRADE LANDSCAPING 2% CL PROFILE GRADE CONSTRUCT SIDEWALK PER DETAIL 4-11 SEE SHEET C4.9 (TYP) 2% CONSTRUCT CEMENT CONCRETE ROLLED CURB AND GUTTER PER DETAIL 4-13 SEE SHEET C4.9 (TYP) SIDEWALK 2% 1' 6' LANDSCAPING 30.5' ROW CONSTRUCTION CL (NOT CL OF ROW) 25.5' ROWROW 18.5' VARIES 0.5' 0.25' HMA CI. 1/2" PG 64-22 0.17' CSTC 0.67' GRAVEL BASE COMPACTED SUBGRADE 2%2% CL PROFILE GRADE 2% CONSTRUCT CEMENT CONCRETE BARRIER CURB AND GUTTER PER DETAIL 4-13 SEE SHEET C4.9 (TYP) 20' EX ROW EX ROW0.5' 20' EX ROWEX ROWCONSTRUCTION CL (NOT CL OF ROW) 16'4.0'ROWFLOW LINEBACK OF CURBFLOW LINEBACK OF CURBFLOW LINEFLOW LINE4.0' ±5.5'±21.7' EX EP EX EP 2% 2% NOT TO SCALE NOT TO SCALE EX ROADWAY PAVEMENT TO BE REMOVED WITHIN ROW SAWCUT PAVEMENT AT ROW LINE MATCH EXISTING GRADE EXISTING ASPHALT TO REMAIN 2% MATCH EXISTING GRADE IN ROW (2:1 MAX SLOPE) MATCH EXISTING GRADE IN ROW (2:1 MAX SLOPE) 2%2:1 MA X . 09/16/2019 81+009+55 10+00 11+00 12+00 13+00 14+00 15+00S1° 43' 57"W 433.54' L =1 5 7 .0 8'R =100.00'Δ =8 9 °59'59"56'37'29.5'R=38' TO FLOW L I N E R=50'RP=STA 10+00, 19.5' LTTO ROW1 335 3 3 6 340336337338339341342 342 34 1 34 1 34 0 341DDDDDD335 80+00 81+00 12+0013+00S88° 16' 03"E 205.10'311+0029.5' 34 0 3 3 9 3 4 1 342341341342343344DDDD 320 325 330 335 340 345 350 355 9+50 335.9810+00335.73335.9810+50336.48336.9811+00337.48337.9811+50338.49339.1012+00339.82340.5612+50341.21341.7513+00342.19342.5113+50342.73342.8314+00342.83342.7114+50342.49342.1515+00341.718"Ø WATER M A I N 4"Ø SEWER MAIN 2.02% 2.00% 3.00% PVI: 335.48 PVI STA: 10+00.00 K: 12.45 50' VC BVCS: 9+75.00BVCE: 335.98EVCS: 10+25.00EVCE: 335.98LOW PT: 10+00.10ELEV: 335.73PVI: 338.80 PVI STA: 11+66.00 K: 50.00 50' VC BVCS: 11+41.00BVCE: 338.30EVCS: 11+91.00EVCE: 339.55PVI: 346.27 PVI STA: 14+15.00 K: 57.14 400' VC BVCS: 12+15.00BVCE: 340.27HI PT: 13+86.43ELEV: 342.84GRADE BREAK STA: 9+55.37ELEV: 336.38BEGIN 'A' ROAD SEFINISHED CL GRADE EXISTING GRADE STA: 9+99.99, 57.72 L IE: 331.42 12" (S) IE: 331.42 12" (W) RIM: 334.57 CB #1, CB TYPE 1 76 LF 12" CPEP STORM @ 0.50% STA: 10+00.01, 18.72 R IE: 331.80 12" (E) IE: 331.80 12" (S) RIM: 335.35 CB #2, CB TYPE 1 225 LF 12" CPEP STOR M @ 1 . 2 6 % STA: 12+25.33, 18.72 L IE: 337.16 8" (W) RIM: 340.19 CB #5, CB TYPE 1 STA: 12+25.33, 18.28 R IE: 334.64 12" (N) IE: 336.79 8" (E) IE: 334.64 12" (W) RIM: 340.41 CB #3, 48" TYPE 2 CB 37 LF 8" CPEP STORM @ 1.00% 325 330 335 340 345 350 355 360 325 330 335 340 345 350 355 360 79+50 80+00344.24343.7280+50342.99342.2081+00341.40340.7181+50340.9682+00 2.00% 3.17% 2.00% GRADE BREAK STA: 80+00.00 ELEV: 344.24 GRADE BREAK STA: 81+51.34 ELEV: 340.99 PVI: 340.52 PVI STA: 81+27.84 K: 4.83 25' VC BVCS: 81+15.34BVCE: 340.92EVCS: 81+40.34EVCE: 340.77LOW PT: 81+30.67ELEV: 340.67PVI: 343.67 PVI STA: 80+28.50 K: 21.35 25' VC BVCS: 80+16.00BVCE: 343.92EVCS: 80+41.00EVCE: 343.27EXISTING GRADE FINISHED CL GRADE 4" Ø SEWER MAIN STA: 80+14.13, 15.08 L IE: 335.23 12" (E) IE: 335.23 12" (S) IE: 335.23 12" (N) RIM: 343.92 CB #50, 48" TYPE 2 CB 101 LF 12" CPEP STORM @ 0.50% STA: 81+14.84, 15.08 L IE: 334.73 12" (E) IE: 337.12 8" (S) IE: 334.73 12" (W) RIM: 340.63 CB #6, 48" TYPE 2 CB 18 LF 12" CPEP STORM @ 0.50% STA: 81+33.07, 15.08 L IE: 334.64 12" (N) IE: 336.79 8" (E) IE: 334.64 12" (W) RIM: 340.41 CB #3, 48" TYPE 2 CB 31 LF 8" CPEP STORM @ 1.00% STA: 81+14.78, 15.92 R IE: 337.43 8" (N) RIM: 340.62 CB #7, CB TYPE 1 CB #5 37 LF 8" CPEP STORM @ 1.00% 8" Ø WATER MAIN 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH N GRAPHIC SCALE 0 30 60 1" = 30 FEET 15 DATE: July 6, 2018 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-ROAD.dwg ROAD 'A' AND ROAD 'D' PLAN AND PROFILE C4.0 7NGRAPHIC SCALE 0 30 60 1" = 30 FEET 15 ROAD 'A' STA: 12+40.41 = ROAD 'D' STA: 81+51.35 SEE SHEET C4.6 FOR CUL-DE-SAC GRADING 'A' ROAD SE ROAD & STORM PROFILE SCALE: H:1"=30', V:1"=5' 'D' ROAD SE ROAD & STORM PROFILE SCALE: H:1"=30', V:1"=5'36373839404142434445CONSTRUCT SIDEWALK RAMP PER DETAIL 3A SEE SHT C4.10 CONSTRUCT SIDEWALK RAMP (TYP. THIS SHEET) PER DETAIL 4B SEE SHT C4.9 R=35' STA 80+50.85, 51' LT R=35' STA 80+51.15, 51' RT R=25' STA 81+15.35, 41' LT R=25' STA 81+15.35, 41' RT ROAD "A" STA 12+40.41= ROAD "D" STA 81+51.35 M A T C H L I N E 1 5 + 0 0 SE E S H E E T C4 . 1 MOUNTAIN VIEW RD STA 311+27.78= ROAD "D" STA 80+00 1 ROADWAY NOTES 352 STA 81+15, 15'RT/LT TRANSITION FROM CEMENT CONCRETE BARRIER CURB AND GUTTER TO ROLLED CURB CONSTRUCT LANDSCAPE ISLAND CONTRACTOR TO PROVIDE 6" MIN. SAND CUSHION BETWEEN UTILITIES. CONSTRUCT ROADWAY PER LOCAL RESIDENTIAL STREET-56' ROW, SEE SHEETC3.1 NOTE: 350 345 340 335 330 325 355 SEE THIS SHEET SEE THIS SHEETSTA 9+55.37 BEGIN 'A' RD SE STA 9+55.37 END SIDEWALK MATCHLINE SEE SHEET C4.1SEE SHEET C4.6 FOR INTERSECTION GRADING 2 R=25' STA 81+15.35, 41' LT R=25' STA 81+15.35, 41' RT SEE THIS SHEET SEE SHEET C4.6 FOR INTERSECTION GRADING SEE SHEET C4.8 FOR TRACT 'A' STORM 'A' ROAD SE MOUNTAIN VIEW ROAD SE'D' ROAD SE R=25' STA 10+58.25, 43.50' LT46 4748495051525349 50 51 40 CONSTRUCT ROADWAY PER DETAIL LOCAL RESIDENTIAL STREET-56' ROW, SEE SHEET C3.1 CB #5 CB #7 CB #3 CB #6 CB #50 CB #3 CB #6 CB #7 CB #5 CB #1 CB #43 CB #2 SEE SHEET C4.8 FOR CONTINUATION 320 09/16/2019 50+0051+0030+0031+0042+0043+0015 + 0 0 16+00 17+00 18+00 19+00 20+00 21+00 22+00 23+00 24+00 S88° 16' 03"E 812.75' L = 3 4 0340 3453363363373373 3 8338 3 3 9339341 3413 4 2 3 4 3 3 4 4 3463 4 7 348335335339DDDD DDD DDD 15+00341.71341.1615+50340.50339.7316+00338.85337.8716+50336.88336.1817+00335.84335.8917+50336.29336.7918+00337.29337.7918+50338.29338.7919+00339.29339.7919+50340.29340.7920+00341.29341.7920+50342.29342.7921+00343.29343.7921+50344.29344.7922+00345.29345.7922+50346.29346.7923+00347.28347.6923+50347.98348.1524+00 8"Ø WA T E R M A I N 4"Ø SE W E R M A I N 4.00% 2.00% PVI: 335.15 PVI STA: 16+93.00 K: 16.67 100' VC BVCS: 16+43.00BVCE: 337.15EVCS: 17+43.00EVCE: 336.15LOW PT: 17+09.67ELEV: 335.82EVCS: 16+15.00EVCE: 338.27BVCS: 22+92.09BVCE: 347.13HI PT: 24+00.40EXISTING GRADE FINISHED CL GRADE STA: 17+09.67, 18.72 R IE: 331.80 12" (E) IE: 331.80 12" (N) RIM: 335.44 CB #9, CB TYPE 1L 185 LF 12" CPEP STORM @ 1 . 0 8 % STA: 18+94.27, 18.72 R IE: 333.79 12" (W) IE: 333.79 12" (E) IE: 333.79 12" (N) RIM: 338.80 CB #10, CB TYPE 1 99 LF 12" CPEP STORM @ 3.27% STA: 19+93.58, 18.72 R IE: 337.04 12" (W) IE: 337.37 8" (N) RIM: 340.78 CB #11, CB TYPE 1 37 LF 8" CPEP STORM @ 0.50% STA: 19+93.58, 18.72 L IE: 337.56 8" (S) RIM: 340.78 CB #12, CB TYPE 1 STA: 22+46.46, 18.72 R IE: 342.62 8" (N) RIM: 345.84 CB #13, CB TYPE 1 PVI: 346.27 PVI STA: 14+15.00 K: 57.14 400' VC HI PT: 13+86.43 ELEV: 342.84 PVI: 350.38 PVI STA: 24+54.59 K: 54.16 325' VC HI PT: 24+00.40 ELEV: 348.21 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH DATE: July 6, 2018 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-ROAD.dwg ROAD 'A' PLAN AND PROFILE C4.1 8 N GRAPHIC SCALE 0 30 60 1" = 30 FEET 15 14151617181920212223242526272829303132 CONSTRUCT SIDEWALK RAMP PER DETAIL 4B SEE SHT C4.10 CONSTRUCT SIDEWALK RAMP PER DETAIL 4B SEE SHT C4.10 CONSTRUCT SIDEWALK RAMP PER DETAIL 4B SEE SHT C4.10 37'56'22' 56' 37' 37' 37' R=25' STA 16+40.99, 36' LT R=25' STA 18+76.99, 36' LT R=25' STA 21+91.74, 36' LT R=25' STA 22+63.74, 36' LT R=25' STA 19+48.99, 36' LT R=25' STA 17+12.99, 36' LT ROAD "A" STA 16+76.99= ROAD "B" STA 30+00 ROAD "A" STA 19+12.99= ROAD "C" STA 50+00 ROAD "A" STA 22+27.74= ROAD "B" STA 43+11.3437'56'CONSTRUCT SIDEWALK RAMP PER DETAIL 3B SEE SHT C4.10 CONSTRUCT SIDEWALK RAMP PER DETAIL 3B SEE SHT C4.10 CONSTRUCT SIDEWALK RAMP PER DETAIL 3B SEE SHT C4.10 SEE SHEET C4.7 FOR INTERSECTION GRADING SEE SHEET C4.7 FOR INTERSECTION GRADING SEE SHEET C4.6 FOR INTERSECTION GRADING CONSTRUCT 6' WIDE CONCRETE SIDEWALK PER DETAIL 4-11 SHEET C4.9 CONTRACTOR TO PROVIDE 6" MIN. SAND CUSHION BETWEEN UTILITIES. 'A' ROAD SE ROAD & STORM PROFILE SCALE: H:1"=30', V:1"=5' 350 345 340 335 330 325 355 MATCHLINE SEE SHEET C4.0MATCH LINE 24+00SEE SHEET C4.2MATCH LINE 15+00SEE SHEET C4.0MATCHLINE SEE SHEET C4.2360 350 345 340 335 330 325 355 360 SEE SHEET C4.3 'A' ROAD SE 'A' ROAD SE'B' LOOP SE'B' LOOP SE'C' ROAD SESEE SHEET C4.5 SEE SHEET C4.4 54 55 117 118 104 105106 107 93 94 95 8081 CONSTRUCT ROADWAY PER DETAIL LOCAL RESIDENTIAL STREET-56' ROW, SEE SHEET C3.1 CB #21 CB #22 CB #9 CB #13 CB #36 CB #37 CB #12 CB #11 CB #10 CB #38 CB 39 29.5'09/16/2019 320 325 330 335 340 345 350 355 24+00348.21348.1624+50347.99347.7025+00347.30346.7825+50346.15345.4026+00344.54343.5626+50342.56341.6627+00341.12340.8627+50340.61340.3628+00340.11339.8628+50339.82340.2129+00340.82341.4229+50 8"Ø WATER MAIN 4"Ø SEWER MAIN 8"Ø WATER M A I N 4.00% 1.00% 2.42% PVI: 341.29 PVI STA: 26+81.80 K: 16.66 50' VC BVCS: 26+56.80BVCE: 342.29EVCS: 27+06.80EVCE: 341.04PVI: 339.61 PVI STA: 28+50.00 K: 14.64 50' VC BVCS: 28+25.00BVCE: 339.86EVCS: 28+75.00EVCE: 340.21LOW PT: 28+39.62ELEV: 339.79325' VC PVI: 350.38 PVI STA: 24+54.59 K: 54.16 EVCS: 26+17.09EVCE: 343.88HI PT: 24+00.40ELEV: 348.21GRADE BREAK STA: 29+49.71 ELEV: 342.02 END ROADWAY FINISHED CL GRADE EXISTING GRADE STA: 26+30.67, 18.72 L IE: 338.67 12" (N) IE: 338.67 12" (S) IE: 338.67 12" (E) RIM: 342.96 CB #16, CB TYPE 1 STA: 25+29.16, 18.67 R IE: 343.08 8" (W) RIM: 346.31 CB #14, CB TYPE 1 37 LF 8" CPEP STORM @ 0.50% STA: 25+29.16, 18.72 L IE: 342.56 12" (N) IE: 342.89 8" (E) RIM: 346.30 CB #15, CB TYPE 1 102 LF 1 2 " C P E P S T O R M @ 3 . 8 3 % 209 LF 12" CPEP S T O R M @ 1 . 4 4 % STA: 28+39.64, 18.72 L IE: 335.67 12" (W) IE: 336.00 8" (E) IE: 335.67 12" (S) RIM: 339.41 CB #17, CB TYPE 1 37 LF 8" CPEP STORM @ 0.50% STA: 28+39.64, 18.72 R IE: 336.19 8" (W) RIM: 339.41 CB #18, CB TYPE 1HI PT: 24+00.4090+00 91+00 91+57 26+00KILLION ROADS88° 16' 03"E 182.38' 345 342 343 344 346 343343343D DD 90+0024+0025+00 26+00 27+00 28+00 29+00 29+50 S88° 16' 03"E182.38'N1° 43' 57"E 433.89'L=157.08'R=1 0 0 .0 0'Δ=90° 0 0 ' 0 1 "34834034 0345 3413 4 1 341342343344346 3 4 7348 3 4 3 DD D DD D342 343343344344325 330 335 340 345 350 355 360 325 330 335 340 345 350 355 360 90+00343.97343.4790+50343.05343.1291+00343.2791+50ROAD "E" STA 91+56.88=KILLION RD STA 70+76.02ELEV = 343.438"Ø WATER MAIN 4"Ø SEWER MAIN -2.00% 0.60%GRADE BREAK STA = 90+00.00ELEV = 343.970GRADE BREAK STA = 91+00.79ELEV = 343.273PVI: 342.97 PVI STA: 90+50.00 K: 9.64 25' VC BVCS: 90+37.50BVCE: 343.22EVCS: 90+62.50EVCE: 343.05LOW PT: 90+56.76ELEV: 343.03FINISHED CL GRADE EXISTING GRADE STA: 89+81.28, 15.92 L IE: 338.67 12" (N) IE: 338.67 12" (S) IE: 338.67 12" (E) RIM: 342.96 CB #16, CB TYPE 1 75 LF 12" CPEP STORM @ 0.50% STA: 90+56.76, 15.92 L IE: 339.05 12" (W) IE: 339.38 8" (S) RIM: 342.71 CB #19, CB TYPE 1 32 LF 8" CPEP STORM @ 0.50% STA: 90+56.76, 15.92 R IE: 339.54 8" (N) RIM: 342.71 CB #20, CB TYPE 1 'E' ROAD SE 'A' ROAD SE 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH DATE: July 6, 2018 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-ROAD.dwg ROAD 'A' AND ROAD 'E' PLAN AND PROFILE C4.2 9 N GRAPHIC SCALE 0 30 60 1" = 30 FEET 15 'A' ROAD SE ROAD & STORM PROFILE SCALE: H:1"=30', V:1"=5' 350 345 340 335 330 325 355 MATC H LI N E 2 4 + 0 0 SEE S H E E T C4.1 MATCHLINE SEE SHEET C4.1SEE THIS SHEET109 8765432CONSTRUCT SIDEWALK RAMP PER DETAIL 3B SEE SHT C4.10 34'56'56'37'29.5'STA 25+72.75 36' RT, R=25' STA 90+36 42' LT, R=25' STA 90+36 42' RT, R=25' ROAD "A" STA 26+14.75= ROAD "E" STA 90+00 ROAD "E" STA 90+00= ROAD "A" STA 26+14.75 R = 3 8 ' STA 28+46.25, 43.50' LT R=25' SEE THIS SHEET SEE THIS SHEET 56'37'ROAD "E" STA 91+56.88= KILLION RD STA 70+76.02 SEE SHEET C4.7 FOR INTERSECTION GRADING SEE SHEET C4.7 FOR INTERSECTION GRADING 1R=50'TO ROWT O F L OW L I N E STA 29+05, 19.5'LT CONSTRUCT ROADWAY 'E' PER NEIGHBORHOOD COLLECTOR-56' ROW. SEE SHEET C3.1 STA 29+50 END 'A' RD STA 90+36, 15'RT/LT TRANSITION FROM CEMENT CONCRETE BARRIER CURB AND GUTTER TO ROLLED CURB 2 2 CONSTRUCT LANDSCAPE ISLAND STA 26+56.75 36' RT, R=25'176 77 78 6 7NGRAPHIC SCALE 0 30 60 1" = 30 FEET 15 'A' ROAD SE1 ROADWAY NOTES 2 CONTRACTOR TO PROVIDE 6" MIN. SAND CUSHION BETWEEN UTILITIES. NOTE: 'E' ROAD SE ROAD & STORM PROFILE SCALE: H:1"=30', V:1"=5' 360 73747576777879SEE SHEET C4.8 FOR TRACT ' B' STORM 'E' ROAD SECONSTRUCT ROADWAY PER DETAIL LOCAL RESIDENTIAL STREET-56' ROW, SEE SHEET C3.1 SEE SHEET C4.7 FOR CUL-DE-SAC GRADING CB #15 CB #14 CB #16 CB #17 CB #18 CB #47 CB #16 CB #19 CB #20 09/16/2019 320 325 330 335 340 345 350 355 360 8"Ø WATER MAIN 4"Ø SEWER MAIN 30+00336.14335.6430+50335.14334.8231+00334.94335.3431+50335.74336.1332+00336.53336.9332+50337.33337.7233+00338.12338.5233+50338.92339.3234+00339.71340.1134+50340.51340.9135+00341.31341.7035+50342.10342.4936+00342.77342.9036+50342.89342.7437+00342.57342.3937+50342.22342.0538+00341.87341.7038+50 CB#24 -2.00% -0.70% 1.59%GRADE BREAK STA = 30+00.00ELEV = 336.140PVI: 334.59 PVI STA: 30+77.75 K: 13.92 50' VC BVCS: 30+52.75BVCE: 335.09EVCS: 31+02.75EVCE: 334.98LOW PT: 30+80.59ELEV: 334.81PVI: 343.16 PVI STA: 36+16.23 K: 43.66 100' VC BVCS: 35+66.23BVCE: 342.36EVCS: 36+66.23EVCE: 342.81HI PT: 36+35.71ELEV: 342.91FINISHED CL GRADE EXISTING GRADE 100 LF 12" CPEP STORM @ 1 . 0 0 % 243 LF 12" CPEP STORM @ 0.40% STA: 30+80.59, 18.72 L IE: 330.99 12" (E) RIM: 334.43 CB #21, CB TYPE 1 37 LF 12" CPEP STORM @ 0.50% STA: 33+23.16, 17.89 R IE: 329.83 12" (N) IE: 334.52 8" (W) IE: 329.83 12" (S) RIM: 338.11 CB #23, 48" TYPE 2 CB 37 LF 8" CPEP STORM @ 1.00% STA: 33+23.16, 18.72 L IE: 334.89 8" (E) RIM: 338.11 CB #24, CB TYPE 1 90 LF 12" CPEP STORM @ 0.40% STA: 34+09.61, 17.89 L IE: 329.47 12" (NW) IE: 329.47 12" (S) RIM: 339.48 CB #27, 48" TYPE 2 CBSTA: 30+80.59, 18.72 R IE: 330.80 12" (S) IE: 330.80 12" (N) IE: 330.80 12" (W) RIM: 334.43 CB #22, CB TYPE 1L 100 LF 12" CPEP STORM @ 1 . 0 0 %54+0054+2336+00 37+00 38+00S88° 17' 13"E 350.75' 342 30+00 31+00 32+00 33+00 3 4 + 0 0 35+0016+0017+0018+00N1° 43' 57"E 342.66' L = 15 7.0 5 'R= 1 0 0 . 0 0 ' Δ = 8 9 °5 8 ' 5 0 " 3 3 6 33633 7 33733833 8 33 9 3 3 5335 3403 3 6 3 3 7 3 3 8 339341DDDDD DDD2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH DATE: July 6, 2018 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-ROAD.dwg 'B' LOOP PLAN AND PROFILE C4.3 10 N GRAPHIC SCALE 0 30 60 1" = 30 FEET 15 'B' LOOP SE ROAD & STORM PROFILE SCALE: H:1"=30', V:1"=5'MATCHLINE SEE SHEET C4.4NGRAPHIC SCALE 0 30 60 1" = 30 FEET 15 37'STA 35+80.72, 36' RT, R=25' STA 36+52.72, 36' RT, R=25' STA 16+40.99, 36' LT, R=25' STA 17+12.99 36' LT, R=25' ROAD "B" STA 30+00= ROAD "A" STA 16+76.99 ROAD "B" STA 36+16.23= ROAD "C" STA 54+23.20 6160595857565554 118 117 116 115 114 113 11228293056'37'56'37'56'CONSTRUCT SIDEWALK RAMP PER DETAIL 4B SEE SHT C4.10 37' 56' SEE SHEET C4.6 FOR INTERSECTION GRADING CONSTRUCT SIDEWALK RAMP PER DETAIL 4B SEE SHT C4.10 MATCH LINE 35+50 SEE THIS SHEET MATCH LINE 35+50SEE THIS SHEETSEE SHEET C4.1 SEE SHEET C4.1 MATCH LINE 38+50SEE SHEET C4.4350 345 340 335 330 355 360 'B' LOOP SE 'B' LOOP SE 'C' ROAD SESEE SHEET C4.5 65 66 67 68 69 70 71 9899'A' ROAD SECONSTRUCT ROADWAY PER DETAIL LOCAL RESIDENTIAL STREET-56' ROW, SEE SHEET C3.1 SEE SHEET C4.6 FOR INTERSECTION GRADING CONSTRUCT ROADWAY PER DETAIL LOCAL RESIDENTIAL STREET-56' ROW, SEE SHEET C3.1 CONSTRUCT SIDEWALK RAMP PER DETAIL 4B SEE SHT C4.10 CB #9 CB #21 CB #22 CB #24 CB #23 CB #27 CB #45 CB #44 325 320 SEE SHEET C4.8 FOR CONTINUATION 09/16/2019 320 325 330 335 340 345 350 355 360 38+50341.52341.3539+00341.17341.0039+50340.82340.6540+00340.62340.9040+50341.33341.7641+00342.19342.6141+50343.04343.4742+00343.90344.3342+50344.76345.1943+00345.611.71% 2.00%GRADE BREAK STA = 43+00.34ELEV = 345.620GRADE BREAK STA = 43+11.34ELEV = 345.840PVI: 340.47 PVI STA: 40+00.00 K: 20.72 50' VC BVCS: 39+75.00BVCE: 340.65EVCS: 40+25.00EVCE: 340.90LOW PT: 39+89.48ELEV: 340.60FINISHED CL GRADE EXISTING GRADE STA: 39+09.51, 17.89 L IE: 336.04 12" (NE) IE: 336.04 12" (S) RIM: 340.72 CB #32, 48" TYPE 2 CB STA: 39+89.48, 18.72 R IE: 336.46 12" (N) IE: 336.46 12" (S) IE: 336.81 8" (E) RIM: 340.22 CB #35, CB TYPE 1 240 LF 12" CPEP S T O R M @ 1 . 5 9 % 37 LF 12" CPEP STORM @ 0.50% STA: 42+29.34, 18.72 L IE: 340.47 12" (W) IE: 340.80 8" (S) RIM: 344.02 CB #37, CB TYPE 1STA: 39+89.48, 18.72 L IE: 337.00 8" (W) RIM: 340.22 CB #35A, CB TYPE 1 37 LF 8" CPEP STORM @ 0.50% 85 LF 12" CPEP STORM @ 0.50% STA: 42+29.28, 18.72 R IE: 340.28 12" (E) IE: 340.28 12" (N) RIM: 343.98 CB #36, CB TYPE 1 101 LF 8" CPEP S T O R M @ 1 . 8 1 % STA: 22+46.46, 18.72 R IE: 342.62 8" (N) RIM: 345.84 CB #13, CB TYPE 139+0040+00 41+00 42+00 43+00 22+0023+00S1° 43' 57"W 348.28'L=157.11'R=100 .0 0 'Δ=90°01'10"3453443463473413 4 1 3 4 2 3 4 3D DDDDDDD2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH DATE: July 6, 2018 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-ROAD.dwg 'B' LOOP PLAN AND PROFILE C4.4 11NGRAPHIC SCALE 0 30 60 1" = 30 FEET 15 'B' LOOP SE ROAD & STORM PROFILE SCALE: H:1"=30', V:1"=5' MATCH L I N E 3 8 + 5 0 SEE SH E E T C4.3 350 345 340 335 355 R=25' STA 21+91.74, 36' LT R=25' STA 22+63.74, 36' LT ROAD "B" STA 43+11.34= ROAD "A" STA 22+27.74 56'37'CONSTRUCT SIDEWALK RAMP PER DETAIL 4B SEE SHT C4.10 NOTE: CONTRACTOR TO PROVIDE 6" MIN. SAND CUSHION BETWEEN UTILITIES. 'B' LOOP SE 'A' ROAD SESEE SHEET C4.1 SEE SHEET C4.1 MATCHLINE SEE SHEET C4.3330 81828384858687 88 89 90 91 92 93 94 SEE SHEET C4.7 FOR INTERSECTION GRADING CB #32 CB #35 CB #37 CB #36 CB #13 325 320 360 SEE SHEET C4.8 FOR CONTINUATION CB #35A 09/16/2019 325 330 335 340 345 350 355 360 325 330 335 340 345 350 355 360 50+00339.55339.0550+50338.69338.4451+00338.34338.5451+50338.88339.2352+00339.58339.9252+50340.27340.6253+00340.96341.3153+50341.65342.0054+00342.438"Ø WATER MAIN 4"Ø SEWER MAIN -2.00% -1.00% 1.39% 2.00%GRADE BREAK STA = 50+00.00ELEV = 339.550GRADE BREAK STA = 50+36.00ELEV = 338.830GRADE BREAK STA = 53+87.16ELEV = 342.169GRADE BREAK STA = 54+23.20ELEV = 342.890PVI: 338.19 PVI STA: 51+00.00 K: 20.97 50' VC BVCS: 50+75.00BVCE: 338.44EVCS: 51+25.00EVCE: 338.54LOW PT: 50+95.95ELEV: 338.34EXISTING GRADE FINISHED CL GRADE 115 LF 12" CPEP STORM @ 0.50% STA: 50+95.95, 18.72 R IE: 334.88 8" (W) RIM: 337.96 CB #39, CB TYPE 1 STA: 50+95.95, 18.72 L IE: 334.69 8" (E) IE: 334.36 12" (S) RIM: 337.96 CB #38, CB TYPE 1 37 LF 8" CPEP STORM @ 0.50% 50+00 51+00 52+00 53+00 54+00 54+23 36+0037+0019+0020+00S88° 16' 03"E812.75'S88° 17' 13"E350.75'N1° 43' 57"E 423.20'34033833934133 9339D DDD 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH DATE: July 6, 2018 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-ROAD.dwg 'C' ROAD PLAN AND PROFILE C4.5 12 'C' ROAD SE ROAD & STORM PROFILE SCALE: H:1"=30', V:1"=5'NGRAPHIC SCALE 0 30 60 1" = 30 FEET 15 SEE SHEET C4.122'37'56'R=25' STA 35+72.72, 43.50' RT R=25' STA 36+52.22, 36' RT R=25' STA 18+76.99, 36' LT R=25' STA 19+48.99, 36' LT ROAD "C" STA 50+00= ROAD "A" STA 19+12.99 ROAD "C" STA 54+23.20= ROAD "B" STA 36+16.23 37'56'CONSTRUCT SIDEWALK RAMP PER DETAIL 4B SEE SHT C4.10 CONSTRUCT SIDEWALK RAMP PER DETAIL 4B SEE SHT C4.10 NOTE: CONTRACTOR TO PROVIDE 6" MIN. SAND CUSHION BETWEEN UTILITIES.'A' ROAD SESEE SHEET C4.1 SEE SHEET C4.1 SEE SHEET C4.1 'B' LOOP SE'C' ROAD SE 99100101102103104105 106 107 108 109 110 111 SEE SHEET C4.7 FOR INTERSECTION GRADING SEE SHEET C4.6 FOR INTERSECTION GRADING CB #10 CB #38 CB #39 09/16/2019 'A' ROAD SE2% 2% 2% 2%2%9+5510+0011+00FG: 335.95FG: 335.95 FG: 336.38 FG: 335.66 FG: 335.41 FG: 334.87 FG: 334.53 FG: 334.66 FG: 335.16 FG: 335.36 FG: 335.30 FG: 335.73 FG: 335.83 FG: 336.21 FG: 336.64 FG: 336.21'B' LOOP SE'A' ROAD SEFG: 338.49 FG: 337.60 FG: 336.80 FG: 335.14 FG: 338.93 FG: 338.03 FG: 337.23 FG: 338.50 FG: 337.74 FG: 336.95 FG: 334.74 FG: 335.02 FG: 335.42 FG: 334.38 FG: 334.81 FG: 334.38 FG: 335.14 FG: 334.74 FG: 336.04 FG: 335.59 FG: 336.51 FG: 335.39 FG: 335.34 FG: 335.44 FG: 335.24 FG: 335.55 FG: 335.98 FG: 335.98 FG: 336.41 FG: 335.69 FG: 335.99 FG: 335.82 FG: 335.5416+00 17+00 30+0031+00FG: 335.70 FG: 336.14 'C' ROAD SE'B' LOOP SE 36+00 37+00 54+0054+23FG: 341.46 FG: 341.83 FG: 342.13 FG: 341.89 FG: 342.56FG: 342.26 FG: 341.98 FG: 342.34 FG: 341.90 FG: 341.47 FG: 341.15 FG: 341.61 FG: 341.89 FG: 341.57 FG: 341.20 FG: 341.61 FG: 342.17 FG: 341.89 FG: 342.11 FG: 342.00 FG: 342.23 FG: 342.24 FG: 342.42 FG: 342.06 FG: 342.45 FG: 342.33 FG: 342.88 FG: 342.76 FG: 342.60 FG: 342.48 FG: 342.60 FG: 342.17FG: 342.44 FG: 342.89'D' ROAD SEMOUNTAIN VIEW ROAD SE 'A' ROAD SE STA 80+50.99, 0'RT BEGINNING OF ISLAND STA 81+15.35, 0'RT END OF ISLAND R=25' R=20'R=20' R=25' FG: 344.23 FG: 343.14 FG: 343.98 FG: 342.62 FG: 342.88 FG: 343.40 FG: 342.96 FG: 342.61 FG: 343.86 FG: 343.07 FG: 343.31 FG: 342.84 FG: 343.68 FG: 343.55 FG: 340.58 FG: 341.46 FG: 340.84 FG: 341.79FG: 342.08 FG: 340.54 FG: 341.89 FG: 341.61 FG: 342.22 FG: 341.94FG: 342.52 FG: 342.09 FG: 341.35 FG: 341.10 FG: 340.92 FG: 340.58 FG: 340.31 FG: 339.77 FG: 340.04 FG: 339.76 FG: 340.96 FG: 340.98 FG: 339.34 FG: 339.49 FG: 338.76 FG: 338.18 FG: 339.19 FG: 338.61 FG: 338.90 FG: 338.18 311+00 312+00 80+0081+0012+0013+00 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH GRAPHIC SCALE 0 20 40 1" = 20 FEET 10 DATE: July 6, 2018 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-ROAD-INTX.dwg INTERSECTION PLANS C4.6 13 N N NN 09/16/2019 'B' LOOP SE'A' ROAD SE 22+00 23+0042+0043+00FG: 344.85 FG: 344.56 FG: 344.03 FG: 344.45 FG: 344.03 FG: 344.56 FG: 345.05 FG: 344.98 FG: 344.95 FG: 344.84 FG: 345.19 FG: 346.28 FG: 345.59 FG: 345.50 FG: 346.16 FG: 344.91 FG: 344.91 FG: 345.41 FG: 345.84 FG: 344.44 FG: 343.84 FG: 343.83 FG: 344.29 FG: 344.72FG: 344.26 FG: 345.12 FG: 344.69 FG: 346.56 FG: 346.13 FG: 346.68 FG: 346.98 FG: 346.96 FG: 347.40 FG: 346.97 FG: 346.53 'A' ROAD SE2%2% 2% 2%2.4%2.4%28+0029+0029+50FG: 341.59 FG: 342.02 FG: 341.59 FG: 340.94 FG: 340.01 FG: 341.52 FG: 341.40 FG: 339.37 FG: 339.51FG: 339.94FG: 339.61 FG: 340.49 FG: 340.99 FG: 341.66 FG: 341.70 FG: 339.99 FG: 340.32 FG: 339.89 FG: 339.67FG: 340.10FG: 339.77 FG: 340.34 FG: 340.67 FG: 340.24 FG: 340.74 FG: 341.07 FG: 340.63 FG: 341.11 FG: 341.44 FG: 341.01 FG: 341.39 FG: 341.72 FG: 341.29 FG: 339.60 FG: 339.41 FG: 339.41 'A' ROAD SE'C' ROAD SE18+00 19+00 20+00 50+0051+00FG: 338.83 FG: 338.40 FG: 339.05 FG: 338.80 FG: 338.80 FG: 338.55 FG: 338.55 FG: 339.84 FG: 339.27 FG: 338.91 FG: 339.63 FG: 339.33 FG: 338.83 FG: 338.55 FG: 338.00FG: 337.54 FG: 337.97 FG: 338.43 FG: 337.55 FG: 338.15 FG: 339.12 FG: 339.55 FG: 340.27 FG: 340.24 FG: 340.70 FG: 340.67 FG: 341.13 FG: 340.38 FG: 340.78 FG: 339.99 FG: 338.35 FG: 337.98 FG: 338.40 FG: 338.63 FG: 338.35 FG: 337.98 STA 90+36, 0'RT END OF ISLAND STA 90+99.87, 0'RT BEGINNING OF ISLAND R=25' R=20'R=20' R=25''E' ROAD SE'A' ROAD SE 25+00 26+00 27+00 90+0091+00FG: 345.64 FG: 345.04FG: 346.24 FG: 346.67 FG: 346.25 FG: 346.07 FG: 345.79 FG: 345.47 FG: 345.19 FG: 343.54 FG: 343.97 FG: 343.75 FG: 342.91 FG: 342.91 FG: 341.86 FG: 344.06 FG: 342.47 FG: 342.71 FG: 342.24FG: 344.63 FG: 343.50 FG: 343.25 FG: 342.29 FG: 341.18 FG: 340.69 FG: 341.61 FG: 341.13FG: 342.01 FG: 341.33 FG: 340.70 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH GRAPHIC SCALE 0 20 40 1" = 20 FEET 10 DATE: July 6, 2018 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-ROAD-INTX.dwg INTERSECTION PLANS C4.7 14 N N NN 09/16/2019 335340336 337 338339341341 335 340 336 337 338 339 341 342 D D D D D D DD D D D 34034160' 140' 15'3363373383393413 4 2 3423 4 3 34334 4 344D D D DD DD DD 58.5' 78' 45' 48.95' 19.73' 26.7' 10' 340 339 341 342 343 4' ELEV=330.79 ELEV=334.79 PL MIN 3' OVERLAP 330 335 340 345 330 335 340 345 342.190+50342.47342.901+00343.19342.971+50342.71341.28PL EXISTING GRADE FINISHED GRADE 78'48.95'47.77'0.1' 1 1/2"-2" WASHED DRAIN ROCK 140W MARAFI FILTER FABRIC INSTALL 12" CPEP STORM PIPE COMPACT FILL OVER BASIN TO 90% MODIFIED PROCTOR CONSTRUCT 45'x78' ROCK GALLERY PER DETAIL 4' ELEV=328.10 PL 140W MARAFI FILTER FABRIC MIN 3' OVERLAP ELEV=324.10 322 325 330 335 340 322 325 330 335 340 334.820+50335.17336.031+00336.78337.531+50338.28339.032+00339.81341.39FINISHED GRADE EXISTING GRADE CONSTRUCT 60'x140' ROCK GALLERY PER DETAIL 1 1/2"-2" WASHED DRAIN ROCKINSTALL 12" CPEP STORM PIPE 15'140' 10' PL COMPACT FILL OVER BASIN TO 90% MODIFIED PROCTOR 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH N GRAPHIC SCALE 0 20 40 1" = 20 FEET 10 A A B B WEST STORM NOTES 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 EAST STORM NOTES 1 2 3 4 5 6 7 8 9 10 11 12 13 18 19 20 14 21 22 15 WEST DRAINAGE BASIN EAST DRAINAGE BASIN CB#1 23 CB#43 CB#44 CB#45 CB#46 CB#47A CB#44 TYPE 2 48"Ø CB W/ FRAME AND GRATE RIM= 339.70 IE= 329.01 (N,E,W) 5 LF 12" CPEP STORM PIPE S= 2.00% 13 LF 12" CPEP STORM PIPE S= 1.00% STORMWATER INFILTRATION BASIN CLEANOUT PER DETAIL ON SHEET C4.11 RIM= 335.69 IE= 325.94 (E) BAYFILTER MODEL BF 5-10-5 DETAIL ON SHEET C4.12 RIM= 337.92 IE= 328.90 (S) IE= 326.07 (N) 72 LF 12" PERFORATED CPEP STORM PIPE S= 0.0% 68 LF 12" PERFORATED CPEP STORM PIPE S= 0.0% STORMWATER INFILTRATION BASIN CLEANOUT PER DETAIL ON SHEET C4.11 RIM= 339.93 IE= 325.89 (W) 20 LF 12" PERFORATED CPEP STORM PIPE S= 0.0% STORMWATER INFILTRATION BASIN CLEANOUT PER DETAIL ON SHEET C4.11 RIM= 339.88 IE= 325.94 (W) 68 LF 12" PERFORATED CPEP STORM PIPE S= 0.0% 72 LF 12" PERFORATED CPEP STORM PIPE S= 0.0% STORMWATER INFILTRATION BASIN CLEANOUT PER DETAIL ON SHEET C4.11 RIM= 337.67 IE= 325.94 (E) 87 LF 12" PVC STORM PIPE S= 0.5% CB#47 TYPE 2 48"Ø W/ FRAME AND GRATE RIM= 341.77 IE= 335.23 (W,E,N) 124 LF 12" ADS N-12 STORM PIPE S= 0.51% 24 LF 12" ADS N-12 STORM PIPE S= 0.5% 3 LF 12" ADS N-12 STORM PIPE S= 1.0% 14 LF 12" CPEP STORM PIPE S= 0.72% STORMWATER INFILTRATION BASIN CLEANOUT PER DETAIL ON SHEET C4.11 RIM= 342.31 IE= 332.20 (E) 23 LF 12" PERFORATED CPEP STORM PIPE S= 0.0% 78 LF 12" PERFORATED CPEP STORM PIPE S= 0.0% STORMWATER INFILTRATION BASIN CLEANOUT PER DETAIL ON SHEET C4.11 RIM= 342.69 IE= 332.20 (E) SECTION B-B SCALE: H:1"=20', V:1"=2'SECTION A-A SCALE: H:1"=20', V:1"=2' SEE SHEET C4.0 FOR CONTINUATION SEE SHEET C4.4 FOR CONTINUATION SEE SHEET C4.2 FOR CONTINUATION SEE SHEET C4.3 FOR CONTINUATION 1 2 3 4 5 6 78 12 10 1925 24 26 27 28 11 18 20 21 CB#44C CB#44B CB#44A 10' 10' 21' CONSTRUCT 60'x140' ROCK GALLERY PER DETAIL CB#44C TYPE 2 48"Ø CB W/ FRAME AND GRATE RIM= 337.84 IE= 325.94 (S,E,W) 9 20 LF 12" PERFORATED CPEP STORM PIPE S= 0.0% CB#47B TYPE 2 48"Ø CB W/ FRAME AND GRATE RIM= 343.26 IE= 332.20 (S,W) 13 STORMWATER INFILTRATION BASIN CLEANOUT PER DETAIL ON SHEET C4.11 RIM= 335.72 IE= 325.94 (E) 14 72 LF 12" PERFORATED CPEP STORM PIPE S= 0.0% 15 CB#44A TYPE 2 48"Ø CB W/ FRAME AND GRATE RIM= 337.90 IE= 325.94 (N,S,E,W) 16 68 LF 12" PERFORATED CPEP STORM PIPE S= 0.0% 17 STORMWATER INFILTRATION BASIN CLEANOUT PER DETAIL ON SHEET C4.11 RIM= 339.98 IE= 325.94 (W) 22 23 REFER TO ROAD 'A' PROFILE SHEET C4.02426 99 LF 12" ADS N-12 STORM PIPE S= 2.26% 25 CB#43 TYPE 1 RIM= 336.24 IE= 331.25 (N,E) 28 27 CB#45 TYPE 2 48"Ø CB W/ FRAME AND GRATE RIM= 340.82 IE= 329.24 (W,SE) 58 LF 12" ADS N-12 STORM PIPE S= 0.4% 56 LF 12" ADS N-12 STORM PIPE S= 0.4% 22 23 1 11 13 5 7 17 3 9 15 2 10 14 4 8 16 1 2 3 4 5 6 7 8 9 10 14 11 12 13 15 CB#47B CB#47 CONSTRUCT 45'x78' ROCK GALLERY PER DETAIL 78 LF 12" PERFORATED CPEP STORM PIPE S= 0.0% CB#47A TYPE 2 48"Ø CB W/ FRAME AND GRATE RIM= 342.59 IE= 332.20 (S,N,W) CB#46 TYPE 2 48"Ø CB W/ FRAME AND GRATE RIM= 341.37 IE= 335.92 (SW,E) DATE: July 2, 2018 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-PONDS.dwg DRAINAGE PONDS DETAILS C4.8 15 CB#44B TYPE 2 48"Ø CB W/ FRAME AND GRATE RIM= 339.87 IE= 325.94 (N,E,S,W) BAYFILTER MODEL BF 5-7-2 DETAIL ON SHEET C4.12 RIM= 342.04 IE= 332.27 (N) IE= 335.20 (S) 34 LF 12" ADS N-12 STORM PIPE S= 0.50% 1 5 3 7 09/16/2019 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH DATE: June 12, 2018 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-ROAD-DETL.dwg ROAD NOTES AND DETAILS C4.9 16 1.ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH CITY OF YELM STANDARD, AND THE MOST CURRENT COPY OF THE STATE OF WASHINGTON STANDARD SPECIFICATIONS FOR ROAD, BRIDGE, AND MUNICIPAL CONSTRUCTION. 2.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TRAFFIC CONTROL IN ACCORDANCE WITH MUTCD. PRIOR TO DISRUPTION OF ANY TRAFFIC, TRAFFIC CONTROL PLANS SHALL BE PREPARED AND SUBMITTED TO THE CITY FOR APPROVAL. NO WORK SHALL COMMERCE UNTIL ALL APPROVED TRAFFIC CONTROL IS IN PLACE. 3.ALL CURB AND GUTTER, STREET GRADES, SIDEWALK GRADES, AND ANY OTHER VERTICAL AND/OR HORIZONTAL ALIGNMENT SHALL BE STAKED BY AN ENGINEERING OR SURVEYING FIRM CAPABLE OF PERFORMING SUCH WORK. 4.WHERE NEW ASPHALT JOINS EXISTING, THE EXISTING ASPHALT SHALL BE CUT TO A NEAT VERTICAL EDGE AND TACKED WITH ASPHALT EMULSION TYPE CSS-1 IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS. THE NEW ASPHALT SHALL BE FEATHERED BACK OVER EXISTING TO PROVIDE FOR A SEAL AT THE SAW CUT LOCATION AND THE JOINT SEALED WITH GRADE AR-4000W PAVING ASPHALT. 5.COMPACTION OF SUBGRADE, ROCK, AND ASPHALT SHALL BE IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS. 6.SUBGRADE INSPECTION SHALL BE PERFORMED BY AN APPROVED TESTING FIRM AND FORMS SHALL BE INSPECTED FOR LINE AND GRADE BY AN ENGINEER BEFORE POURING CONCRETE. 7.CERTIFICATION AS TO CONFORMANCE SHALL BE PROVIDED TO THE CITY PRIOR TO ACCEPTANCE OF WORK. 8.THE CONTRACTOR/ DEVELOPER SHALL FURNISH AND INSTALL ALL PERMANENT SIGNING. PL 5' MIN FROM PL DRIVEWAY PORTION OF SIDEWALK TO BE 6" THICK 6' 20' MAX. 5' SIDEWALK BACK OF CURB 6" THICK CONCRETE DRIVEWAY NOT TO SCALE NOTE: DRIVEWAY LOCATIONS TO BE IDENTIFIED BY THE CONTRACTOR PRIOR TO POURING THE SIDEWALKS OR ALL SIDEWALKS SHOULD BE 6" THICK. NOT TO SCALE 5' WIDE SIDEWALK PLANTER STRIP AS REQUIRED 2%2% 2% 4" CONCRETE GENERAL NOTES: 1.FOR JOINTS AND SCORING, SEE STANDARD FOR SIDEWALK 4-11. 2.CONCRETE DRIVEWAYS REQUIRE A MINIMUM DEPTH OF 6". CEMENT CONCRETE ROLLED CURB AND GUTTER 09/16/2019 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH DATE: June 12, 2018 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-ROAD-DETL.dwg ROAD NOTES AND DETAILS C4.10 17 RAMP 3/16"B A BA A B C D MIN.MAX. 1 5/8"2 3/8" 5/8"C D 7/16" 7/8"1 7/16" 3/4" 1 1/2" DETECTABLE WARNING PATTERN DETAIL PLAN ELEVATION DETECTABLE WARNING PATTERN AREA SHALL BE YELLOW, IN COMPLIANCE WITH STD. SPEC. 8-14.3(3) TRUNCATED DOMES NOT TO SCALE OPENINGSEE CONTRACT FOR CURB RETURN RADIUS 5' - 0"6' - 0" F G RADIUS POINT OF SIDEWALK RAMP AND CURB RETURN MIN. CEMENT CONCRETE PEDESTRIAN CURB 5' - 0 " M I N . 2' - 0 " SIDEWALK RAMP WSDOT TYPE 3B E CONSTRUCT CEMENT CONCRETE SIDEWALK RAMP CURB, OR CURB AND GUTTER RAMP CENTERLINE SIDEWALK PLANTER STRIP NOT TO SCALE 2' - 0"4"-2% SECTION4"-2%6"SECTION 6' - 0" MIN.6"4"VARIES ~ 0 TO 6" 5' - 0" RAMP 6"6" (TYP.) SECTION E F G TOP OF ROADWAY TOP OF ROADWAY 5' - 0" MIN. 5' - 0" MIN.6' - 0" MIN. RAMP BUFFER STRIP CEMENT CONCRETE PEDESTRIAN CURB (TYP.) (SEE WSDOT STD. PLAN F-1) CEMENT CONCRETE PEDESTRIAN CURB (SEE WSDOT STD. PLAN F-1) CEMENT CONCRETE SIDEWALK CEMENT CONCRETE CURB & GUTTER (SEE NOTE) CEMENT CONCRETE SIDEWALK 16.69' A 5' - 0"6' - 0" RAMP C LANDING 1.70' DISTANCE FROM P.C. B RADIUS POINT OF CURB RETURN 5' - 0"RA D I U S SE E C O N T R A C T (AT C U R B F A C E ) SECTION 2' - 0" 6' - 0" RAMP 4"4"6" LANDING B6"4"-2%WW5' - 0" SECTION A SECTION C VARIES 0 TO 6" 5' - 0" RAMP 4"DETECTABLE WARNING PATTERN (SEE DETAIL THIS SHEET) TOP OF ROADWAY TOP OF ROADWAY TOP OF ROADWAY DEPRESSED CURB & GUTTER (SEE NOTE) 3/8" EXPANSION JOINT (SEE WSDOT STD. PLAN F-3) 3/8" EXPANSION JOINT (SEE WDOT STD. PLAN F-3) BUFFER STRIP BUFFER STRIP BUFFER STRIP VARIES 0 TO W CEMENT CONCRETE PEDESTRIAN CURB (SEE WSDOT STD. PLAN F-1) CEMENT CONCRETE CURB & GUTTER (SEE NOTE) CEMENT CONCRETE CURB & GUTTER (SEE NOTE)CEMENT CONCRETE PEDESTRIAN CURB CEMENT CONCRETE SIDEWALK CEMENT CONCRETE SIDEWALK MINOR STREETCURB, OR CURB AND GUTTER `cCROSSWALKDETECTABLE WARNING PATTERN (SEE DETAIL THIS SHEET) CEMENT CONCRETE SIDEWALK RAMP TYPE 4BSIDEWALK MAJOR STREET SIDEWALK RAMP WSDOT TYPE 4B NOT TO SCALE 4"B OPE NI N G 5' - 0" MIN. 3'-0" MIN. RAMP 5' - 0" MIN. C SIDEWALK RAMP TYPE 3A SEE CONTRACT FOR CURB RETURN RADIUS LANDING SECTION C RAMP3"2' - 0" LANDING 3"RAMP 3"4"-2% BSECTION RAMP 3"4"-2%6"SECTION A SIDEWALK RADIUS POINT OF SIDEWALK RAMP AND CURB RETURN TOP OF ROADWAY TOP OF ROADWAY 5' - 0" MIN.3' - 0" MIN. 5' - 0" MIN.3' - 0" MIN. DETECTABLE WARNING PATTERN (SEE DETAIL THIS SHEET) 3' - 0" MIN.3' - 0" MIN.5' - 0" MIN. BUFFER STRIP 3/8" EXPANSION JOINT (TYP.) (SEE STD. PLAN F-3) 3/8" EXPANSION JOINT (TYP.) (SEE WSDOT STD. PLAN F-3) DEPRESSED CURB & GUTTER (SEE NOTE) CEMENT CONCRETE PEDESTRIAN CURB DETECTABLE WARNING PATTERN (SEE DETAIL THIS SHEET) CEMENT CONCRETE PEDESTRIAN CURB (SEE WSDOT STD. PLAN F-1) CEMENT CONCRETE CURB & GUTTER (SEE NOTE) 5' - 0" MIN. 2' - 0 " CEMENT CONCRETE SIDEWALK CL CROSSWALK CROSSWALKCLPLAN VIEW LAYOUT 1 RAMP CENTERLINE SIDEWALK CEMENT CONCRETE PEDESTRIAN CURB A CEMENT CONCRETE SIDEWALK RAMP TYPE 3A CURB, OR CURB AND GUTTER SIDEWALK RAMP WSDOT TYPE 3A NOT TO SCALE 4-10 0.17' CRUSHED SURFACING TOP COURSE PUBLIC WORKS DIRECTOR DATE APPROVED CITY OF YELM STANDARDS. AND MUNICIPAL CONSTRUCTION AS AMENDED BY STANDARD SPECIFICATIONS FOR ROAD, BRIDGE ATION SHALL BE IN CONFORMANCE WITH THE ALL MATERIALS, WORKMANSHIP, AND INSTALL- NOTES: 1. OR MATCH EXISTING PLUS 0.08', WHICHEVER IS GREATER. 1' MIN. TYP. 10/3/94 RESTORATION DETAIL TRENCH-PAVEMENT DWG. NO. DES. DWN. CKD. DATE DEPT. OF PUBLIC WORKS CITY OF YELM SAW CUT EXISTING PAVEMENT. 2-03.3(14)C METHOD C COMPACTED PER. SEE STANDARD PLAN A-1 TRENCH BACKFILL EXISTING PAVEMENT S-C S-C RIGID TOP COURSE SURFACING 0.17' CRUSHED MINIMUM 0.75' CEMENT CONC. PVMT. PLUS 0.08', WHICHEVER IS GREATER APPLIED IN MAXIMUM 0.17' LIFTS MINIMUM 0.25' CLASS 'B' A.C.P. (COMPACTED DEPTH) OR EXISTING TYP. 1' MIN. TRANSVERSE CONSTRUCTION JOINT. USING PAVING ASPHALT AR4000W. TO EDGES OF EXISTING PAVEMENT. 2-03.3(14)C METHOD B COMPACTED PER. PAVEMENT SAW CUT EXISTING PAVEMENT. FLEXIBLE ALL JOINTS SHALL BE SEALED CSS-1 TACK SHALL BE APPLIED EMULSIFIED ASPHALT GRADE TRENCH BACKFILL EXISTING S-C CURB & GUTTER IS SHOWN, SEE THE CONTRACT PLANS FOR THE CURB DESIGN SPECIFIED. SEE DETAIL 4-13 ON SHEET C4.9 FOR CURB DETAILS. NOTE: NOTE: PLANTER STRIP CURB & GUTTER IS SHOWN, SEE THE CONTRACT PLANS FOR THE CURB DESIGN SPECIFIED. SEE DETAIL 4-13 ON SHEET C4.9 FOR CURB DETAILS. DEPRESSED CURB & GUTTER (SEE NOTE) DETECTABLE WARNING PATTERN (SEE DETAIL THIS SHEET) NOTE: CURB & GUTTER IS SHOWN, SEE THE CONTRACT PLANS FOR THE CURB DESIGN SPECIFIED. SEE DETAIL 4-13 ON SHEET C4.9 FOR CURB DETAILS. PLAN VIEW PLAN VIEW 0.67' GRAVEL BASE COMPACTED TO 95% OF MAXIMUM DENSITY PER. 2-03.3(14)D 0.67' GRAVEL BASE COMPACTED TO 95% OF MAXIMUM DENSITY PER. 2-03.3(14)D DETECTABLE WARNING PATTERN (SEE DETAIL THIS SHEET) 09/16/2019 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH DATE: July 6, 2018 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-STRM-DETL.dwg STORM DRAINAGE NOTES AND DETAILS C4.11 18 5" TOP OF THE BASE) (MEASUREMENT AT THE PRECAST BASE SECTION CATCH BASIN TYPE 1 NOT TO SCALE #3 BAR EACH WAY 26" MIN #3 BAR EACH SIDE #3 BAR EACH CORNER 2 - #3 BAR HOOP 4" 5" MI N 3" 4" 17" 20" 44" 4" MIN MI N 4" 4" 22 " 12" 12" RISER SECTION 6" RISER SECTION PLAN FOR DETAILS) SPECIFIED (SEE STANDARD FRAME AND GRATE AS DRAINAGE AND GRADING NOTES 1 - #3 BAR HOOP 34" 5" 34" 20 " 24" 5" 24" 5" 30 " 20 " 5" 6" 5"5" 30 " ROOF DRYWELL POSSIBLE ALIGNMENTS PLAN VIEW NOT TO SCALE ROOF DRAIN 4" PERFORATED PIPE DRY WELL NOT TO SCALE PROFILE VIEW 6" MIN. 2'-0" MIN. ROOF DRAIN LEVEL LEVEL A A 4" PERFORATED PIPE (CPEP SINGLE WALL ACCEPTABLE) 4'2' MIN. ROOF STRUCTURE COMPACT BACKFILL6" MIN. FILTER FABRIC ON TOP 5' 4" PERFORATED PIPE WASHED ROCK `R" - 1`2" SECTION A-A NOT TO SCALE ROOF DOWNSPOUT SYSTEM (DRYWELL) NOT TO SCALE 6" MIN.2.5'INSTALL: 4"Ø ADS DRAIN PIPE INSTALL: (TYPICAL) FOOTING CAP AT END INSTALL: 12" MIN. BETWEEN BOTTOM OF FOOTING AND TOP OF ROCK IN DRYWELL 4"Ø-90° BEND 8" NOTE: #4 @ 7" O.C. EACH WAY TOP TONING WIRE 6" THREADED PLUG 4"Ø PVC PIPE WITH CONCRETE BLOCK NOT TO SCALE 4" NIPPLE 12" PVC FLEX COUPLING -2% CL PROFILE GRADE 2% NOT TO SCALE CONSTRUCTION CL OFFSET FROM CONSTRUCTION CL NOT TO SCALE CEMENT CONCRETE ROLLED CURB AND GUTTER TYPE I CB W/ FRAME AND OFCOBACK OF CURBCENTER OF GRATE/STRUCTURE TO CL OF STRUCTURE/GRATE FLOW LINE OF CURB 1.0' 0.78' SM-44 GRATE -2% CL PROFILE GRADE CEMENT CONCRETE CURB AND GUTTER OFFSET FROM CONSTRUCTION CL TO CL STRUCTURE/GRATE 2%CL GRATEFLOW LINETYPE I CB W/ FRAME AND GRATE FLOW LINE OF CURB CENTER OF GRATE/STRUCTURE 1.08' CONSTRUCTION CL 8" PVC PIPE ASTM D - 3034 (WHITE) NOTES: 1.CATCH BASINS TO BE CONSTRUCTED IN ACCORDANCE WITH ASTM C 478 (AASHTO M 199) AND ASTM C 890, UNLESS OTHERWISE SHOWN ON PLANS OR NOTED IN THE STANDARD SPECIFICATIONS. 2.AS AN ACCEPTABLE ALTERNATE TO REBAR, WELDED WIRE FABRIC HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED. WELDED WIRE FABRIC SHALL COMPLY TO ASTM A 497 (AASHTO M 221). WIRE FABRIC SHALL NOT BE PLACED IN THE KNOCKOUTS. 3.THE BOTTOM OF THE PRECAST BASE SECTION MAY BE ROUNDED. 4.PRECAST BASES SHALL BE FURNISHED WITH CUTOUTS OR KNOCKOUTS. KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2 INCHES MINIMUM. KNOCKOUTS MAY BE ON ALL 4 SIDES EITHER ROUND OR "D" SHAPE. PIPE TO BE INSTALLED IN FACTORY SUPPLIED KNOCKOUTS. KNOCKOUT OR CUTOUT HOLE SIZE IS EQUAL TO PIPE OUTER DIAMETER PLUS CATCH BASIN WALL THICKNESS (20 INCHES MAXIMUM). 5.THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE PIPE INVERT IS 5 FEET. 6.THE TAPER ON THE SIDES OF THE PRECAST BASE SECTION AND RISER SECTION SHALL NOT EXCEED 0.5 INCHES PER FOOT. 7.FRAME AND GRATE MAY BE INSTALLED WITH FLANGE DOWN OR CAST INTO RISER. 1.COMPLY WITH ALL OTHER PERMITS AND OTHER REQUIREMENTS BY CITY OF YELM OR OTHER GOVERNING AUTHORITY OR AGENCY. 2.IN AREAS UNDER STRUCTURES, PAVING SECTIONS AND SIDEWALKS, STRIP ALL TOPSOIL AND ORGANIC MATERIAL. FOR STRUCTURAL FILL IN AREAS UNDER FOOTINGS AND SLABS ON GRADE, ALL SOILS SHALL BE COMPACTED TO A MINIMUM DENSITY OF 90% OF ASTM D-1557 OR 95% OF UBC 70-1. THIS INCLUDES PROOF-ROLLING NATIVE SOILS EXPOSED IN THE BOTTOM OF THE EXCAVATION PRIOR TO PLACEMENT OF FILL. MATERIALS UNDER THE PAVING SECTION SHALL ALSO BE COMPACTED TO THE MINIMUM DENSITY BY PROOF-ROLLING PRIOR TO PLACEMENT OF THE PAVING SECTION; THIS INCLUDES PROOF-ROLLING IN-PLACE SOILS, SOILS THAT HAVE BEEN DISTURBED DURING CONSTRUCTION AND ALL STRUCTURAL FILL MATERIALS. 3.FOR IMPORTED STRUCTURAL FILL A CLEAN, SIX-INCH MINUS, WELL GRADED GRAVEL OR GRAVELLY SAND (CLASSIFYING AS GW OR SW AS DETERMINED BY ANSI/ASTM TEST METHOD D-2487) SHALL BE USED. NO MORE THAN 7% BY WEIGHT SHALL PASS THE #200 SCREEN AS TESTED BY ANSI/ASTM D-1140 TEST PROCEDURE. OTHER MATERIAL MAY BE SUBSTITUTED WITH PRIOR APPROVAL BY A GEOTECHNICAL CONSULTANT FOR USE. 4.ALL FILL SHALL BE PLACED IN UNIFORM HORIZONTAL LIFTS OF SIX TO EIGHT INCHES LOOSE THICKNESS, CONDITIONED TO THE OPTIMUM MOISTURE CONTENT, AND COMPACTED TO THE SPECIFIED MINIMUM DENSITY BEFORE PLACING THE NEXT LIFT. ALL UTILITY TRENCH BACKFILL SHALL BE COMPACTED AS SPECIFIED ABOVE. STORMFILTER INFILTRATION BASIN CLEANOUT DETAIL CURB AND GUTTER CATCH BASIN OFFSET DETAIL ROLLED CURB AND GUTTER CATCH BASIN OFFSET DETAIL THE 4" VALVE MAY BE BELL x BELL AT THE CONTRACTORS OPTION 4"Ø SCH 80 PVC PIPE FROM VALVE W/SOLVENT WELD JOINTS NOTE: FOR TYPE 2 48" MANHOLES FLOWLINE IS AT THE SAME LOCATION AS FOR TYPE 1 CATCH BASINS. CENTER OF STRUCTURE IS 1.61' FROM BACK OF CURB. NOTE: FOR TYPE 2 48" MANHOLES, FLOWLINE IS AT THE SAME LOCATION AS FOR TYPE 1 CATCH BASINS. CENTER OF STRUCTURE IS 1.92' FROM FACE OF CURB. 09/16/2019 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH DATE: July 6, 2018 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-STRM-DETL.dwg BAYFILTER DETAILS C4.12 19 09/16/2019 81+009+55 10+00 11+00 12+00 13+00 14+00 15+00S1° 43' 57"W 433.54' Δ=89°59'59" R=100.00' L=157.08' S88° 16' 03"E 205.10'56'37'29.5'DDDDDD80+00 81+00 12+0013+00S1° 43' 57"W433.54'S88° 16' 03"E 205.10'311+00312+0029.5'DD DD325 330 335 340 345 350 355 360 9+50 335.9810+00335.73335.9810+50336.48336.9811+00337.48337.9811+50338.49339.1012+00339.82340.5612+50341.21341.7513+00342.19342.5113+50342.73342.8314+00342.83342.7114+50342.49342.1515+00341.718"Ø WATER M A I N 42" MIN COVER 8"Ø WATER MAIN 3 2 1 6 7 8 4"Ø SEWE R M A I N 1 2 3 4 5 6 60" MIN COVER5 4"Ø SEWER MAIN EXISTING GRADE FINISHED CL GRADE 12"Ø STORM DRAIN 325 330 335 340 345 350 355 360 325 330 335 340 345 350 355 360 79+50 80+00 343.8180+50343.11342.3281+00341.53340.7781+50340.8882+00 42" MIN COVER 60" MIN COVER 9 10 3 3 8 7 8" WA T E R M A I N 4"SE W E R M A I N EXISTING GRADE FINISHED CL GRADE APPROXIMATE LOCATION OF GAS LINE APPROXIMATE LOCATION OF PHONE LINE 12"Ø STORM DRAIN 8"Ø STORM DRAIN 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH N GRAPHIC SCALE 0 30 60 1" = 30 FEET 15 DATE: July 12, 2018 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-UTIL.dwg ROAD 'A' AND ROAD 'D' UTILITY PLAN C6.0 20NGRAPHIC SCALE 0 30 60 1" = 30 FEET 15 'A' ROAD SE SEWER & WATER PROFILE SCALE: H:1"=30', V:1"=5' 'D' ROAD SE SEWER & WATER PROFILE SCALE: H:1"=30', V:1"=5' M A T C H L I N E 1 5 + 0 0 SE E S H E E T C6 . 1 350 345 340 335 330 325 355 SEE THIS SHEET SEE THIS SHEET MATCHLINE SEE SHEET C6.1SEE THIS SHEET 'A' ROAD SE MOUNTAIN VIEW ROAD SE'D' ROAD SE WATER NOTES:SEWER NOTES: 3 6 8 7 10 1 1 1 2 3 4 2 3 4 NOT USED STA 12+34.41, 21' LT INSTALL FIRE HYDRANT PER DETAIL 6-7 ON SHEET 24 CONNECT TO 8" CROSS SEE NOTE 3 INSTALL 185 LF 8" C900 CL 150 WATER MAIN STA 14+20.24, 1.19' LT INSTALL 1-45° BEND (MJxMJ) 1-THRUST BLOCK 6 7 8 INSTALL 90 LF 8" C900 CL 150 WATER MAIN STA 80+04.17, 6' LT CONNECT TO EXISTING 8" WATER MAIN PER DETAIL 6-10 SHEET C6.9 INSTALL 153 LF 8" C900 CL 150 WATER MAIN STA 311+92.19, 18.49' RT INSTALL 1-1" METER SERVICE 1-1" FEBCO MODEL 850 OR DOH APPROVED DOUBLE CHECK VALVE IN BOX, CONTRACTOR TO COORDINATE W/ LANDSCAPE PLANS. 9 1012'12'STA 9+60, 6' RT INSTALL TYPICAL END OF LINE CLEANOUT PER DETAIL 7-20 SHEET C6.10 INSTALL 286 LF 4" PVC 1PS 1120 SDR 21 CLASS 200 SEWER PIPE STA 12+46.41, 6' RT INSTALL 1-4" TEE (SLxSLxSL) 3-4" GATE VALVE (MJxMJ) PER DETAIL 7-21 ON SHEET C6.10 1-THRUST BLOCK 4 INSTALL 178 LF 4" PVC 1PS 1120 SDR 21 CLASS 200 SEWER PIPE STA 14+21.16, 11.76' RT INSTALL 1-45° BEND (SLxSL) 1-THRUST BLOCK INSTALL 100 LF 4" PVC 1PS 1120 SDR 21 CLASS 200 SEWER PIPE 7 STA 80+14.11, 6' LT CONNECT TO EXISTING 4" SEWER MAIN 1-4" GATE VALVE (MJxMJ) PER DETAIL 7-21 ON SHEET C6.10 1-THRUST BLOCK INSTALL 131 LF 4" PVC 1PS 1120 SDR 21 CLASS 200 SEWER PIPE 2 3 5 6 8 6 5 6' 6' 6'6' 6' 6' 5 "A" ROAD SE454443424140393837363541 40 48 49 504647484950515253ROAD "A" STA 12+40.41= ROAD "D" STA 81+51.35 MOUNTAIN VIEW RD STA 311+27.28= ROAD "D" STA 80+00 ROAD "D" STA 81+51.35= ROAD "A" STA 12+40.41 5 2 1 5 3 8 9 7 11 11 NOTE: THE DEVELOPER IS RESPONSIBLE FOR THE COST OF THE FIRE HYDRANT LOCKS AND THE CITY OF YELM WATER DEPARTMENT WILL ORDER AND INSTALL THEM. 360 STA 9+57, 6' LT INSTALL 2" BLOWOFF ASSEMBLY PER DETAIL 6-9 ON SHT 24 1-8" GATE VALVE (MJxFL) 1-8" BLIND FLANGE 1-THRUST BLOCK INSTALL 273 LF 8" C900 CL 150 WATER MAIN STA 12+34.41, 6' LT INSTALL 1-8" CROSS (FLxFLxFLxFL) 3-8" GATE VALVE (FLxMJ) PER DETAIL 6-11 ON SHT 25 1-THRUST BLOCK 1-8"-6" REDUCER (FLxFL) 09/16/2019 50+0051+0030+0031+0042+0043+0015 + 0 0 16+00 17+00 18+00 19+00 20+00 21+00 22+00 23+00 24+00 S88° 16' 03"E 812.75' Δ=89°59'59" R=100.00' L=157.08' 12'12'12'12'12'12' 6' 6' 6' 6' 6' 6' 6' 6'DDDDD DDD 15+00341.71341.1615+50340.50339.7316+00338.85337.8716+50336.88336.1817+00335.84335.8917+50336.29336.7918+00337.29337.7918+50338.29338.7919+00339.29339.7919+50340.29340.7920+00341.29341.7920+50342.29342.7921+00343.29343.7921+50344.29344.7922+00345.29345.7922+50346.29346.7923+00347.28347.6923+50347.98348.1524+00 350 345 340 335 330 325 355 8"Ø WA T E R M A I N 4"Ø SE W E R M A I N EXISTING GRADE FINISHED CL GRADE 360 350 345 340 335 330 325 360 8"Ø WATER M A I N 42" MIN COVER 4"Ø SEWE R M A I N 1 1 60" MIN COVER 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 2 3 4 5 6 7 8 9 10 11 MAINTAIN 18" MIN. CLEARANCE AT INTERSECTION CROSSING 12 MAINTAIN 18" MIN. CLEARANCE AT INTERSECTION CROSSING MAINTAIN 18" MIN. CLEARANCE AT INTERSECTION CROSSING 355 12"Ø STORM DRAIN 12"Ø STO R M D R A I N 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH DATE: July 12, 2018 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-UTIL.dwg ROAD 'A' UTILITY PLAN C6.1 21 N GRAPHIC SCALE 0 30 60 1" = 30 FEET 15 14151617181920212223242526272829303132 'A' ROAD SE SEWER & WATER PROFILE SCALE: H:1"=30', V:1"=5'MATCHLINE SEE SHEET C6.0MATCH LINE 15+00SEE SHEET C6.0SEE SHEET C6.3 'A' ROAD SE'B' LOOP SE'B' LOOP SESEE SHEET C6.4 SEE SHEET C6.4 WATER NOTES:SEWER NOTES: 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 6 11 2 3 4 5 7 8 9 10 17 ROAD "A" STA 16+76.99= ROAD "B" STA 30+00 ROAD "A" STA 19+12.99= ROAD "C" STA 50+00 ROAD "A" STA 22+27.74= ROAD "B" STA 43+11.34 12 18 MATCHLINE SEE SHEET C6.2'C' ROAD SEMATCH LINE 24+00SEE SHEET C6.217 1615 14 13 1211 10 9 87 6 5 432 1 11 12 10 9876 18 5432 1 STA 15+14.6, 1.2' LT INSTALL 1-45° BEND (MJxMJ) 1-THRUST BLOCK INSTALL 90 LF 8" C900 CL 150 WATER MAIN INSTALL 118 LF 8" C900 CL 150 WATER MAIN STA 16+33.5, 22' LT INSTALL FIRE HYDRANT PER DETAIL 6-7 ON SHEET C6.8 INSTALL 49 LF 8" C900 CL 150 WATER MAIN STA 16+82.99, 6' LT INSTALL 1-8" TEE (FLxFLxFL) 3-8" GATE VALVE (FLxMJ) PER DETAIL 6-11 ON SHEET C6.9 1-THRUST BLOCK INSTALL 194 LF 8" C900 CL 150 WATER MAIN STA 18+77, 22' LT INSTALL FIRE HYDRANT PER DETAIL 6-7 ON SHEET C6.8 INSTALL 30 LF 8" C900 CL 150 WATER MAIN STA 19+07, 6' LT INSTALL 1-8" TEE (FLxFLxFL) 3-8" GATE VALVE (FLxMJ) PER DETAIL 6-11 ON SHEET C6.9 1-THRUST BLOCK INSTALL 277 LF 8" C900 CL 150 WATER MAIN STA 21+83±, 22' LT INSTALL FIRE HYDRANT PER DETAIL 6-7 ON SHEET C6.8 INSTALL 37 LF 8" C900 CL 150 WATER MAIN STA 22+21.7, 6' LT INSTALL 1-8" TEE (FLxFLxFL) 3-8" GATE VALVE (FLxMJ) PER DETAIL 6-11 SHEET C6.9 1-THRUST BLOCK INSTALL 167 LF 8" C900 CL 150 WATER MAIN STA 23+90, 1.2' LT INSTALL 1-45° BEND (MJxMJ) 1-THRUST BLOCK INSTALL 83± LF 8" C900 CL 150 WATER MAIN INSTALL 1-1" METER SERVICE 1-1" FEBCO MODEL 850 OR DOH APPROVED DOUBLE CHECK VALVE IN BOX, CONTRACTOR TO COORDINATE W/ LANDSCAPE PLANS. INSTALL 100 LF 4" PVC 1PS 1120 SDR 21 CLASS 200 SEWER PIPE STA 15+14, 11.7' RT INSTALL 1-4" 45° BEND (SLxSL) 1-THRUST BLOCK INSTALL 160 LF 4" PVC 1PS 1120 SDR 21 CLASS 200 STA 16+71, 6' RT INSTALL 1-4" TEE (SLxSLxSL) 2-4" GATE VALVE (MJxMJ) PER DETAIL 7-21 ON SHEET C6.10 1-FLxMJ ADAPTER 1-THRUST BLOCK INSTALL 248 LF 4" PVC 1PS 1120 SDR 21 CLASS 200 INSTALL 160 LF 4" PVC 1PS 1120 SDR 21 CLASS 200 STA 22+34, 6' RT INSTALL 1-4" TEE (SLxSLxSL) 2-4" GATE VALVE (MJxMJ) PER DETAIL 7-21 ON SHEET C6.10 1-FLxMJ ADAPTER 1-THRUST BLOCK INSTALL 315 LF 4" PVC 1PS 1120 SDR 21 CLASS 200 STA 19+19, 6' RT INSTALL 1-4" TEE (SLxSLxSL) 2-4" GATE VALVE (MJxMJ) PER DETAIL 7-21 ON SHEET C6.10 1-FLxMJ ADAPTER 1-THRUST BLOCK STA 23+84, 21.5' RT INSTALL 1-4" 45° BEND (SLxSL) 1-THRUST BLOCK INSTALL 100 LF 4" PVC 1PS 1120 SDR 21 CLASS 200 SEWER PIPE STA 23+84.35, 21.53' RT INSTALL 1-AIR RELEASE VALVE PER DETAIL 7-21 ON SHEET C6.10. CONNECT TO HIGH POINT ON SEWER MAIN 54 117 118 104 105106 107 8081 93 94 95 09/16/2019 325 330 335 340 345 350 355 360 24+00348.21348.1624+50347.99347.7025+00347.30346.7825+50346.15345.4026+00344.54343.5626+50342.56341.6627+00341.12340.8627+50340.61340.3628+00340.11339.8628+50339.82340.2129+00340.82341.4229+50 8"Ø WATER MAIN 42" MIN COVER 1 4"Ø SEWER MAIN 60" MIN COVER 2 3 4 6 7 8 1 2 3 4 5 6SEE ENCASEMENT NOTE THIS SHEET EXISTING GRADE FINISHED CL GRADE 12"Ø S T O R M D R A I N 12"Ø STORM DRAI N 90+00 91+00 91+57 26+00KILLION ROADS88° 16' 03"E 182.38'DDD 90+0024+0025+00 26+00 27+00 28+00 29+00 29+50 S88° 16' 03"EN1° 43' 57"E 433.89'L=1 5 7 . 0 8 'R = 1 0 0.0 0'Δ= 9 0 ° 0 0 '0 1"DD D DD D330 335 340 345 350 355 360 330 335 340 345 350 355 360 90+00343.97343.4790+50343.05343.1291+00343.2791+50 42" MIN COVER 60" MIN COVER 4 7 8 6 9 10 8"Ø WATER MAIN 4"Ø SEWER MAIN SEE ENCASEMENT NOTE THIS SHEET BURIED TELEPHONE EXISTING 4" STEP EXISTING 10" WATER WATER AND SEWER LINES TO BE INSTALLED AS PART OF SR 510/ KILLION RD LID No.2-PHASE II (BY OTHERS) EXISTING GRADE FINISHED CL GRADE 12"Ø STORM DRAIN 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH DATE: July 12, 2018 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-UTIL.dwg ROAD 'A' AND ROAD 'E' UTILITY PLAN C6.2 22 N GRAPHIC SCALE 0 30 60 1" = 30 FEET 15 'A' ROAD SE PROFILE SCALE: H:1"=30', V:1"=5' 350 345 340 335 330 325 355 MATC H LI N E 2 4 + 0 0 SEE S H E E T C6.1 MATCHLINE SEE SHEET C4.1SEE THIS SHEET109 8765432SEE THIS SHEET SEE THIS SHEET 176 77 78NGRAPHIC SCALE 0 30 60 1" = 30 FEET 15 'E' ROAD SE PROFILE SCALE: H:1"=30', V:1"=5' 360 'A' ROAD SE'A' ROAD SE 'E' ROAD SE WATER NOTES:SEWER NOTES: 1 4 6 1 6 1 1 8 5 9 6 7 8 4 3 2 10 12' 12' INSTALL 100 LF 4" PVC 1PS 1120 SDR 21 CLASS 200 SEWER PIPE STA 24+83.57, 11.76' RT INSTALL 1-4" 45° BEND (SLxSL) 1-THRUST BLOCK INSTALL 128 LF 4" PVC 1PS 1120 SDR 21 CLASS 200 SEWER PIPE 4 STA 26+08.75, 6' RT INSTALL 1-4" TEE (SLxSLxSL) 3-4" GATE VALVE (MJxMJ) PER DETAIL 7-21 ON SHEET C6.10 1-THRUST BLOCK INSTALL 335 LF 4" PVC 1PS 1120 SDR 21 CLASS 200 SEWER PIPE STA 29+44, 6' RT INSTALL END OF LINE CLEANOUT PER DETAIL 7-20 ON SHEET C6.10 7 INSTALL 94 LF 4" PVC 1PS 1120 SDR 21 CLASS 200 SEWER PIPE STA 91+55.87, 6' RT CONNECT TO EXISTING 4" STEP MAIN REMOVE EXISTING CAP AND THRUST BLOCK 2 3 5 6 8 6 6' 6'12'6' 6' 6' 6' ROAD "E" STA 90+00= ROAD "A" STA 26+14.75 CENTER 20 LF OF SANITARY SEWER MAIN BELOW WATER MAIN SO JOINTS WILL BE EQUIDISTANT FROM WATER MAIN CROSSING. ENCASE SANITARY SEWER MAIN IN PRESSURE RATE PVC PIPE WITH A DIMENSION RATIO (DR) OF 18 OR LESS. ENCASEMENT NOTE: INSTALL 1-1" METER SERVICE (IRRIGATION) 1-1" FEBCO MODEL 850 OR DOH APPROVED DOUBLE CHECK VALVE IN BOX, CONTRACTOR TO COORDINATE W/ LANDSCAPE PLANS. COORDINATE WITH CITY'S ROADWAY CONTRACTOR FOR RESTORATION AND SCHEDULING. CONTRACTOR TO FIELD VERIFY LOCATION AND DEPTH OF EX UTILITIES PRIOR TO CONSTRUCTION. IF SEWER STUB DOES NOT EXIST THEN INSTALL 1-4" CAP 1-THRUST BLOCK 1-LOCATION MARKER 2 3 4 ROAD "A" STA 26+14.75= ROAD "E" STA 90+00 7 85 2 3 5 9 10 7 4 4 ROAD "E" STA 91+57.00= KILLION RD STA 70+76.02 NOTE: WATER AND SEWER STUBS SHOWN WITHIN THE KILLION ROAD R.O.W. ARE TO BE INSTALLED BY OTHERS. IF THIS WORK HAS NOT BEEN CONSTRUCTED AT THE TIME OF THE CONSTRUCTION CONTEMPLATED IN THESE DRAWINGS, NOTIFY THE ENGINEER. WATER AND SEWER LINES TO BE INSTALLED AS PART OF SR 510/ KILLION RD LID No.2-PHASE II (BY OTHERS)'E' ROAD SEINSTALL 83± LF 8" C900 CL 150 WATER MAIN STA 24+84.5, 1.2' LT INSTALL 1-45° BEND (MJxMJ) 1-THRUST BLOCK INSTALL 135 LF 8" C900 CL 150 WATER MAIN STA 26+21, 22' LT INSTALL FIRE HYDRANT PER DETAIL 6-7 ON SHEET C6.8 CONNECT TO 6" CROSS SEE NOTE 6 STA 26+21, 6' LT INSTALL 1-8" CROSS (FLxFLxFLxFL) 3-8" GATE VALVE (FLxMJ) PER DETAIL 6-11 ON SHT C6.9 1-THRUST BLOCK 1-8"-6" REDUCER (FLxFL) INSTALL 323 LF 8" C900 CL 150 WATER MAIN STA 29+48, 6' LT INSTALL 2" BLOWOFF ASSEMBLY PER DETAIL 6-9 ON SHEET C6.8 1-8" GATE VALVE (MJxFL) 1-8" BLIND FLANGE 1-THRUST BLOCK INSTALL 106 LF 8" C900 CL 150 WATER MAIN STA 91+66, 6' LT CONNECT TO EXISTING 8" WATER MAIN REMOVE EXISTING CAP AND THRUST BLOCK COORDINATE WITH CITY'S ROADWAY CONTRACTOR FOR RESTORATION AND SCHEDULING. CONTRACTOR TO FIELD VERIFY LOCATION AND DEPTH OF EX UTILITIES PRIOR TO CONSTRUCTION. IF WATER STUB DOES NOT EXIST THEN INSTALL 1-8" CAP 1-THRUST BLOCK 1-LOCATION MARKER 7374757677786 7 09/16/2019 325 330 335 340 345 350 355 360 30+00336.14335.6430+50335.14334.8231+00334.94335.3431+50335.74336.1332+00336.53336.9332+50337.33337.7233+00338.12338.5233+50338.92339.3234+00339.71340.1134+50340.51340.9135+00341.31341.7035+50342.10342.4936+00342.77342.9036+50342.89342.7437+00342.57342.3937+50342.22342.0538+00341.87341.7038+50 350 345 340 335 355 360 8"Ø WATER MAIN 4"Ø SEWER MAIN 42" MIN COVER 1 3 5 7 9 2 4 6 8 10 1 2 3 4 5 6 7 8 60" MIN COVER FINISHED CL GRADE EXISTING GRADE 330 325 12"Ø STO R M D R A I N 12"Ø STORM DRAIN 12"Ø STORM DRAIN SEE ENCASEMENT NOTE THIS SHEET 54+0054+2336+00 37+00 38+00S88° 17' 13"E 350.75' 30+00 31+00 32+00 33+00 3 4 + 0 0 35+0016+0017+0018+00N1° 43' 57"E 342.66' L = 15 7.0 5 'R = 1 0 0 . 0 0 ' Δ = 8 9 ° 5 8' 5 0 "12'12'6'6'DDDDD DDD2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH DATE: July 12, 2018 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-UTIL.dwg 'B' LOOP UTILITY PLAN C6.3 23 N GRAPHIC SCALE 0 30 60 1" = 30 FEET 15 'B' LOOP SE PROFILE SCALE: H:1"=30', V:1"=5'MATCHLINE SEE SHEET C6.4NGRAPHIC SCALE 0 30 60 1" = 30 FEET 15 6160595857565554 118 117 116 115 114 113 112282930 MATCH LINE 35+50 SEE THIS SHEET MATCH LINE 35+50SEE THIS SHEETSEE SHEET C6.1 SEE SHEET C6.1 MATCH LINE 38+50SEE SHEET C6.4330 'B' LOOP SE 'B' LOOP SE 'C' ROAD SESEE SHEET C6.4 WATER NOTES: SEWER NOTES: 1 2 3 4 5 6 7 9 10 1 6 1 1 5 8 STA 36+59.72, 22' RT INSTALL FIRE HYDRANT PER DETAIL 6-7 SHEET C6.8 INSTALL 202 LF 8" C900 CL 150 WATER MAIN INSTALL 1-1" METER SERVICE (IRRIGATION) 1-1" FEBCO MODEL 850 OR DOH APPROVED DOUBLE CHECK VALVE IN BOX, CONTRACTOR TO COORDINATE W/ LANDSCAPE PLANS. 2 3 4 6 7 9 10 11 812'12'5 6 7 2 3 4 3 4 5 7 6' 6' 6' 6' 12'12'6' 6' 6' 6' 8 ROAD "B" STA 30+00= ROAD "A" STA 16+76.99 ROAD "B" STA 36+16.23= ROAD "C" STA 54+23.20 11 8 6 2'A' ROAD SESTA 30+06, 6' RT INSTALL 1-8" TEE (FLxFLxFL) 3-8" GATE VALVE (FLxMJ) PER DETAIL 6-11 SHEET C6.9 1-THRUST BLOCK INSTALL 348 LF 8" C900 CL 150 WATER MAIN STA 33+54.47, 1.19' RT INSTALL 1-45° BEND (MJxMJ) 1-THRUST BLOCK INSTALL 90 LF 8" C900 CL 150 WATER MAIN STA 34+48.88, 1.19' RT INSTALL 1-45° BEND (MJxMJ) 1-THRUST BLOCK INSTALL 160 LF 8" C900 CL 150 WATER MAIN STA 36+10.23, 6' RT INSTALL 1-8" TEE (FLxFLxFL) 3-8" GATE VALVE (FLxMJ) PER DETAIL 6-11 SHEET C6.9 1-THRUST BLOCK INSTALL 49 LF 8" C900 CL 150 WATER MAIN STA 29+94, 6' LT INSTALL 1-4" TEE (SLxSLxSL) 2-4" GATE VALVE (MJxMJ) PER DETAIL 7-21 SHEET C6.10 1-FJxMJ ADAPTER 1-THRUST BLOCK INSTALL 365 LF 4" PVC 1PS 1120 SDR 21 CLASS 200 SEWER PIPE STA 33+55.39, 11.76' LT INSTALL 1-4" 45° BEND (SLxSL) 1-THRUST BLOCK INSTALL 100 LF 4" PVC 1PS 1120 SDR 21 CLASS 200 SEWER PIPE STA 34+47.96, 11.76' LT INSTALL 1-4" 45° BEND (SLxSL) 1-THRUST BLOCK INSTALL 177 LF 4" PVC 1PS 1120 SDR 21 CLASS 200 SEWER PIPE STA 36+22.23, 6' LT INSTALL 1-4" TEE (SLxSLxSL) 3-4" GATE VALVE (MJxMJ) PER DETAIL 7-21 SHEET C6.10 1-THRUST BLOCK INSTALL 244 LF 4" PVC 1PS 1120 SDR 21 CLASS 200 SEWER PIPE 65 66 67 68 69 70 71 9899111 09/16/2019 325 330 335 340 345 350 355 360 38+50341.52341.3539+00341.17341.0039+50340.82340.6540+00340.62340.9040+50341.33341.7641+00342.19342.6141+50343.04343.4742+00343.90344.3342+50344.76345.1943+00345.611 2 1 2 8"Ø WATERMAIN 4"Ø SEWER MAIN 42" MIN COVER3 4 3 4 5 6 60" MIN COVER 5 FINISHED CL GRADE EXISTING GRADE 12"Ø STORM DRAI N 8"Ø STORM DRA I N 6" MIN. SEPARATION SEE ENCASEMENT NOTE THIS SHEET39+0040+00 41+00 42+00 43+00 22+0023+00S1° 43' 57"W 348.28'L=157.11'R=100 .0 0 'Δ=90°01'10"12'12'6'6'6'6'DDDDDDDD2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH DATE: July 12, 2018 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-UTIL.dwg 'B' LOOP UTILITY PLAN C6.4 24NGRAPHIC SCALE 0 30 60 1" = 30 FEET 15 'B' LOOP SE PROFILE SCALE: H:1"=30', V:1"=5' MATCH L I N E 3 8 + 5 0 SEE SH E E T C6.3 350 345 340 335 355 56'37'NOTE: CONTRACTOR TO PROVIDE 6" MIN. SAND CUSHION BETWEEN UTILITIES. 'B' LOOP SE 'A' ROAD SESEE SHEET C6.1 SEE SHEET C6.1 MATCHLINE SEE SHEET C6.3360 330 WATER NOTES:SEWER NOTES: 3 53 4 512'63 5 6 ROAD "B" STA 43+11.34= ROAD "A" STA 22+27.74 3 4 4 54 1 2 1 1 2 1 STA 38+63.21, 11.77' LT INSTALL 1-4" 45° BEND (SLxSL) 1-THRUST BLOCK INSTALL 100 LF 4" PVC 1PS 1120 SDR 21 CLASS 200 SEWER PIPE 2 2 325 STA 39+55.81, 11.77' LT INSTALL 1-4" 45° BEND (SLxSL) 1-THRUST BLOCK INSTALL 365 LF 4" PVC 1PS 1120 SDR 21 CLASS 200 SEWER PIPE STA 43+17.34, 6' LT INSTALL 1-4" TEE (SLxSLxSL) 2-4" GATE VALVE (MJxMJ) PER DETAIL 7-21 ON SHEET C6.10 1-FLxMJ ADAPTER 1-THRUST BLOCK STA 40+00, 6' LT INSTALL 1-4" GATE VALVE (MJxMJ) STA 39+56.73, 1.19' RT INSTALL 1-45° BEND (MJxMJ) 1-THRUST BLOCK INSTALL 348 LF 8" C900 CL 150 WATER MAIN STA 43+05.34, 6' RT INSTALL 1-8" TEE (FLxFLxFL) 3-8" GATE VALVE (FLxMJ) PER DETAIL 6-11 SHEET C6.9 1-THRUST BLOCK STA 38+62.29, 1.19' RT INSTALL 1-45° BEND (MJxMJ) 1-THRUST BLOCK INSTALL 90 LF 8" C900 CL 150 WATER MAIN 81 828384858687 88 89 90 91 92 93 94 CENTER 20 LF OF SANITARY SEWER MAIN BELOW WATER MAIN SO JOINTS WILL BE EQUIDISTANT FROM WATER MAIN CROSSING. ENCASE SANITARY SEWER MAIN IN PRESSURE RATE PVC PIPE WITH A DIMENSION RATIO (DR) OF 18 OR LESS. ENCASEMENT NOTE: 09/16/2019 Profile View of C ROAD SE5 325 330 335 340 345 350 355 360 325 330 335 340 345 350 355 360 50+00339.55339.0550+50338.69338.4451+00338.34338.5451+50338.88339.2352+00339.58339.9252+50340.27340.6253+00340.96341.3153+50341.65342.0054+00342.438"Ø WATER MAIN 4"Ø SEWER MAIN 1 2 3 1 2 3 42" MIN COVER60" MIN COVER FINISHED CL GRADEEXISTING GRADE 12"Ø STORM DRAIN SEE ENCASEMENT NOTE THIS SHEET MAINTAIN 18" MIN. CLEARANCE AT INTERSECTION CROSSING 50+00 51+00 52+00 53+00 54+00 54+23 36+0037+0019+0020+00'C' ROAD SE S88° 16' 03"E812.75'S88° 17' 13"E350.75'N1° 43' 57"E 423.20'12'6'6'DDDD 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH DATE: July 12, 2018 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-UTIL.dwg 'C' ROAD UTILITY PLAN C6.5 25 'C' ROAD SE PROFILE SCALE: H:1"=30', V:1"=5'NGRAPHIC SCALE 0 30 60 1" = 30 FEET 15 SEE SHEET C6.1 NOTE: CONTRACTOR TO PROVIDE 6" MIN. SAND CUSHION BETWEEN UTILITIES.'A' ROAD SESEE SHEET C6.1 SEE SHEET C6.1 SEE SHEET C6.1 'B' LOOP SEWATER NOTES:SEWER NOTES: 1 1 2 2 3 12'3 ROAD "C" STA 50+00= ROAD "A" STA 19+12.99 ROAD "C" STA 54+23.20= ROAD "B" STA 36+16.23 19+003 1 2 STA 54+17.20, 6' LT INSTALL 1-8" TEE (FLxFLxFL) 3-8" GATE VALVE (FLxMJ) PER DETAIL 6-11 SHEET C6.9 1-THRUST BLOCK INSTALL 411 LF 8" C900 CL 150 WATER MAIN STA 50+06, 6' LT INSTALL 1-8" TEE (FLxFLxFL) 3-8" GATE VALVE (FLxMJ) PER DETAIL 6-11 ON SHEET C6.9 1-THRUST BLOCK 2 1 3 INSTALL 435 LF 4" PVC 1PS 1120 SDR 21 CLASS 200 SEWER PIPE STA 49+94, 6' RT INSTALL 1-4" TEE (SLxSLxSL) 2-4" GATE VALVE (MJxMJ) PER DETAIL 7-21 ON SHEET C6.10 1-FLxMJ ADAPTER 1-THRUST BLOCK STA 54+29.20, 6' RT INSTALL 1-4" TEE (SLxSLxSL) 3-4" GATE VALVE (MJxMJ) PER DETAIL 7-21 SHEET C6.10 1-THRUST BLOCK 99100101102103104105 106 107 108 109 110 111 CENTER 20 LF OF SANITARY SEWER MAIN BELOW WATER MAIN SO JOINTS WILL BE EQUIDISTANT FROM WATER MAIN CROSSING. ENCASE SANITARY SEWER MAIN IN PRESSURE RATE PVC PIPE WITH A DIMENSION RATIO (DR) OF 18 OR LESS. ENCASEMENT NOTE:09/16/2019 KILLION ROAD'B' LOOP SE'B' LOOP SE'C' ROAD SE'E' ROAD SE 'A' ROAD SE 'B' LOOP SE 'D' ROAD SE 'A' ROAD SE'A' ROAD SEMOUNTAIN VIEW ROAD100' 100' WELL RADIUS. APPROXIMATE LOCATION 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH N GRAPHIC SCALE 0 50 100 1" = 50 FEET 25 DATE: September 16, 2019 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-WATR-OVERALL.dwg WATER SYSTEM AND HYDRANT PLAN C6.6 26 09/16/2019 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH DATE: June 28, 2018 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-UTIL-DETL.dwg UTILITY NOTES AND DETAILS C6.7 27 GENERAL NOTES (WATER MAIN INSTALLATION)GENERAL NOTES (SANITARY SEWER MAIN INSTALLATION) LINE WATER 18" MIN. PIPE SEWER SANITARY WATER AND SEWER CROSSING DETAIL 21. 20. 19. 18. 17. 16. 15. 14. 13. 12. 11. 10. 9. 8. 7. 6. 5. 4. 3. 2. 1.1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. WATER METER SERVICE CONNECTION SCHEDULE LOT #STATION OFFSET DESCRIPTION 1 29+48.73 21.50' RT SINGLE SERVICE WATER METER 2,3 28+54.57 21.50' RT DOUBLE SERVICE WATER METER 4,5 27+54.57 21.50' RT DOUBLE SERVICE WATER METER 6 90+56 20' LT SINGLE SERVICE WATER METER 7 90+56 20' RT SINGLE SERVICE WATER METER 8,9 24+79.58 21.50' RT DOUBLE SERVICE WATER METER 10,11 24+37.28 21.50' RT DOUBLE SERVICE WATER METER 12,13 24+01.87 21.50' RT DOUBLE SERVICE WATER METER 14,15 23+49.24 21.50' RT DOUBLE SERVICE WATER METER 16,17 22+59.24 21.50' RT DOUBLE SERVICE WATER METER 18,19 21+69.24 21.50' RT DOUBLE SERVICE WATER METER 20,21 20+79.24 21.50' RT DOUBLE SERVICE WATER METER 22,23 19+89.24 21.50' RT DOUBLE SERVICE WATER METER 24 & IRR 19+13.75 21.50' RT DOUBLE SERVICE WATER METER 1" IRRIGATION SERVICE METER 25,26 18+23.56 21.50' RT DOUBLE SERVICE WATER METER 27,28 17+33.56 21.50' RT DOUBLE SERVICE WATER METER 29,30 16+43.56 21.50' RT DOUBLE SERVICE WATER METER 31,32 15+53.56 21.50' RT DOUBLE SERVICE WATER METER 33,34 15+03.14 21.50' RT DOUBLE SERVICE WATER METER 35,36 14+69.94 21.50' RT DOUBLE SERVICE WATER METER 37,38 14+25.37 21.50' RT DOUBLE SERVICE WATER METER 39,40 13+30.35 21.50' RT DOUBLE SERVICE WATER METER 41,42 11+50.23 21.50' RT DOUBLE SERVICE WATER METER 43,44 10+50.23 21.50' RT DOUBLE SERVICE WATER METER 45 9+56.38 21.50' RT SINGLE SERVICE WATER METER 46 10+44.59 26' LT SINGLE SERVICE WATER METER 47,48 11+41.59 21.50' LT DOUBLE SERVICE WATER METER 49,50 12+41.59 21.50' LT DOUBLE SERVICE WATER METER 51,52 13+41.59 21.50' LT DOUBLE SERVICE WATER METER 53,54 15+61.67 21.50' LT DOUBLE SERVICE WATER METER 55,56 31+47.68 21.50' LT DOUBLE SERVICE WATER METER 57,58 32+47.68 21.50' LT DOUBLE SERVICE WATER METER 59,60 33+43.46 21.50' LT DOUBLE SERVICE WATER METER 61 & IRR 34+00.75 21.50' LT DOUBLE SERVICE WATER METER 1" IRRIGATION SERVICE METER 62 34+25.60 21.50' LT SINGLE SERVICE WATER METER 63,64 34+79.24 21.50' LT DOUBLE SERVICE WATER METER 65,66 35+79.03 21.50' LT DOUBLE SERVICE WATER METER 67,68 36+79.03 21.50' LT DOUBLE SERVICE WATER METER 69,70 37+79.03 21.50' LT DOUBLE SERVICE WATER METER 71,72 38+67.56 21.50' LT DOUBLE SERVICE WATER METER 73 & IRR 28+31.62 21.50' LT DOUBLE SERVICE WATER METER 1" IRRIGATION SERVICE METER 74,75 27+31.62 21.50' LT DOUBLE SERVICE WATER METER 76,77 26+31.62 21.50' LT DOUBLE SERVICE WATER METER 78,79 25+31.62 21.50' LT DOUBLE SERVICE WATER METER 80,81 23+15.43 21.50' LT DOUBLE SERVICE WATER METER 82,83 41+45.91 21.50' LT DOUBLE SERVICE WATER METER 84,85 40+45.91 21.50' LT DOUBLE SERVICE WATER METER 86,87 39+52.69 21.50' LT DOUBLE SERVICE WATER METER 88,98 38+10.48 21.50' RT DOUBLE SERVICE WATER METER 89,90 40+35.44 21.50' RT DOUBLE SERVICE WATER METER 91,92 41+29.56 21.50' RT DOUBLE SERVICE WATER METER 93,94 42+23.66 21.50' RT DOUBLE SERVICE WATER METER 95,96 20+87.43 21.50' LT DOUBLE SERVICE WATER METER 97,99 37+36.73 21.50' RT DOUBLE SERVICE WATER METER 100,101 52+82.81 21.50' RT DOUBLE SERVICE WATER METER 102,103 51+85.07 21.50' RT DOUBLE SERVICE WATER METER 104,105 50+87.50 21.50' RT DOUBLE SERVICE WATER METER 106,107 50+87.50 21.50' LT DOUBLE SERVICE WATER METER 108,109 51+92.77 21.50' LT DOUBLE SERVICE WATER METER 110,111 52+97.86 21.50' LT DOUBLE SERVICE WATER METER 112,113 34+78.32 21.50' RT DOUBLE SERVICE WATER METER 114,115 32+44.95 21.50' RT DOUBLE SERVICE WATER METER 116,117 31+39.86 21.50' RT DOUBLE SERVICE WATER METER 118 30+53.50 14' RT SINGLE SERVICE WATER METER MT. VIEW (IRRIGATI ON) 311+92.19 18.49' RT 1" SINGLE SERVICE WATER METER SEWER SERVICE CONNECTION SCHEDULE LOT #STATION OFFSET DESCRIPTION 1,2 29+04.75 21.50' RT DOUBLE SERVICE CONNECTION 3,4 28+04.75 21.50' RT DOUBLE SERVICE CONNECTION 5,6 27+04.75 21.50' RT DOUBLE SERVICE CONNECTION 7,8 25+24.75 21.50' RT DOUBLE SERVICE CONNECTION 9,10 24+49.20 21.50' RT DOUBLE SERVICE CONNECTION 11,12 24+18.55 21.50' RT DOUBLE SERVICE CONNECTION 13,14 23+76.31 21.50' RT DOUBLE SERVICE CONNECTION 15,16 23+04.24 21.50' RT DOUBLE SERVICE CONNECTION 17,18 22+14.24 21.50' RT DOUBLE SERVICE CONNECTION 19,20 21+24.24 21.50' RT DOUBLE SERVICE CONNECTION 21,22 20+34.24 21.50' RT DOUBLE SERVICE CONNECTION 23 19+46.39 21.50' RT SINGLE SERVICE CONNECTION 24,25 18+68.57 21.50' RT DOUBLE SERVICE CONNECTION 26,27 17+78.39 21.50' RT DOUBLE SERVICE CONNECTION 28,29 16+88.39 21.50' RT DOUBLE SERVICE CONNECTION 30,31 15+98.39 21.50' RT DOUBLE SERVICE CONNECTION 32,33 15+28.24 21.50' RT DOUBLE SERVICE CONNECTION 34,35 14+86.50 21.50' RT DOUBLE SERVICE CONNECTION 36,37 14+56.11 21.50' RT DOUBLE SERVICE CONNECTION 38,39 13+80.23 21.50' RT DOUBLE SERVICE CONNECTION 40 12+91.41 21.50' RT SINGLE SERVICE CONNECTION 41 11+91.41 21.50' RT SINGLE SERVICE CONNECTION 42,43 11+00.41 21.50' RT DOUBLE SERVICE CONNECTION 44 10+05 21.50' RT SINGLE SERVICE CONNECTION 45 9+95 21.50' RT SINGLE SERVICE CONNECTION 46,47 10+91.41 21.50' LT DOUBLE SERVICE CONNECTION 48,49 11+91.41 21.50' LT DOUBLE SERVICE CONNECTION 50,51 12+91.41 21.50' LT DOUBLE SERVICE CONNECTION 52 13+88.41 21.50' LT SINGLE SERVICE CONNECTION 53 15+23.75 21.50' LT SINGLE SERVICE CONNECTION 54,55 30+97.50 21.50' LT DOUBLE SERVICE CONNECTION 56,57 31+97.50 21.50' LT DOUBLE SERVICE CONNECTION 58,59 32+97.50 21.50' LT DOUBLE SERVICE CONNECTION 60,61 33+76.54 21.50' LT DOUBLE SERVICE CONNECTION 62,63 34+36.70 21.50' LT DOUBLE SERVICE CONNECTION 64,65 35+28.85 21.50' LT DOUBLE SERVICE CONNECTION 66,67 36+28.85 21.50' LT DOUBLE SERVICE CONNECTION 68,69 37+28.85 21.50' LT DOUBLE SERVICE CONNECTION 70,71 38+28.85 21.50' LT DOUBLE SERVICE CONNECTION 72 38+94.73 21.50' LT SINGLE SERVICE CONNECTION 73,74 27+81.43 21.50' LT DOUBLE SERVICE CONNECTION 75,76 26+81.43 21.50' LT DOUBLE SERVICE CONNECTION 77,78 25+81.43 21.50' LT DOUBLE SERVICE CONNECTION 79,80 23+65.25 21.50' LT DOUBLE SERVICE CONNECTION 81 22+79 21.50' LT SINGLE SERVICE CONNECTION 82 41+92.73 21.50' LT SINGLE SERVICE CONNECTION 83,84 40+95.73 21.50' LT DOUBLE SERVICE CONNECTION 85,86 39+95.73 21.50' LT DOUBLE SERVICE CONNECTION 87 39+26.98 21.50' LT SINGLE SERVICE CONNECTION 88 39+84.89 21.50' RT SINGLE SERVICE CONNECTION 89 39+96.57 21.50' RT SINGLE SERVICE CONNECTION 90,91 40+82.67 21.50' RT DOUBLE SERVICE CONNECTION 92,93 41+76.79 21.50' RT DOUBLE SERVICE CONNECTION 94 42+63 21.50' RT SINGLE SERVICE CONNECTION 95 20+36.49 21.50' LT SINGLE SERVICE CONNECTION 96 21+04.24 21.50' LT SINGLE SERVICE CONNECTION 97,98 37+56.73 21.50' RT DOUBLE SERVICE CONNECTION 99,100 53+30.74 21.50' RT DOUBLE SERVICE CONNECTION 101,102 52+32.99 21.50' RT DOUBLE SERVICE CONNECTION 103,104 51+35.25 21.50' RT DOUBLE SERVICE CONNECTION 105 50+50 21.50' RT SINGLE SERVICE CONNECTION 106 50+50 21.50' LT SINGLE SERVICE CONNECTION 107,108 51+40.04 21.50' LT DOUBLE SERVICE CONNECTION 109,110 52+45.13 21.50' LT DOUBLE SERVICE CONNECTION 111,112 35+28.55 21.50' RT DOUBLE SERVICE CONNECTION 113 34+24.02 21.50' RT SINGLE SERVICE CONNECTION 114 34+94.67 21.50' RT SINGLE SERVICE CONNECTION 115,116 31+92.58 21.50' RT DOUBLE SERVICE CONNECTION 117,118 30+87.50 21.50' RT DOUBLE SERVICE CONNECTION ALL FITTINGS USED FOR THE SEWER INSTALLATION SHALL BE PVC. FITTINGS SHALL BE SLxSL EXCEPT FOR GATE VALVES THAT MY BE MJxMJ. ALL WORKMANSHIP AND MATERIAL SHALL BE IN ACCORDANCE WITH CITY OF YELM STANDARDS AND THE MOST CURRENT COPY OF THE STATE OF WASHINGTON STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION. ALL WORK IN CITY RIGHT-OF-WAY REQUIRES A PERMIT FROM THE CITY OF YELM. PRIOR TO ANY WORK COMMENCING, THE GENERAL CONTRACTOR SHALL ARRANGE FOR A PRECONSTRUCTION MEETING TO BE ATTENDED BY ALL MAJOR CONTRACTORS, REPRESENTATIVES OF INVOLVED UTILITIES, AND THE CITY OF YELM. CONTACT THE PUBLIC WORKS DEPARTMENT AT (360) 458-8410 TO SCHEDULE THE MEETING. THE CONTRACTOR IS RESPONSIBLE TO HAVE A SET OF APPROVED PLANS AT THE MEETING. WATER MAINS SHALL MEET THE FOLLOWING SPECIFICATIONS: POLYVINYL CHLORIDE (PVC) PIPE (UNDER 4 INCHES): PIPE MATERIAL SHALL BE PVC 1120, PVC 1220, OR PVC 2120, AND HAVE MINIMUM WALL THICKNESS EQUAL TO OR LESS THAN THE STANDARD DIMENSION RATIO (SDR) OF 21, AND MEET THE REQUIREMENTS OF WSDOT STANDARD SPECIFICATIONS SECTION 9-30.1(5)B. POLYVINYL CHLORIDE (PVC) PIPE (4 THROUGH 12 INCHES): SHALL MEET THE REQUIREMENTS OF AWWA C900, CLASS 150 WALL THICKNESS EQUAL TO OR GREATER THAN THE SDR OF 18, AND MEET THE REQUIREMENTS OF WSDOT STANDARD SPECIFICATIONS SECTION 9-30.1(5)A. POLYVINYL CHLORIDE (PVC) PIPE (14 THROUGH 20 INCHES): SHALL MEET THE REQUIREMENTS OF AWWA C905 WALL THICKNESS EQUAL TO OR LESS THAN THE SDR OF 18. DUCTILE IRON PIPE (DIP): DIP SHALL CONFORM TO AWWA C151 CLASS 50 OR GREATER, AND SHALL BE 1/16-INCH CEMENT LINED AND SEALED IN ACCORDANCE WITH ANSI/AWWA C104/A21.4-90, AND MEET THE REQUIREMENTS OF WSDOT STANDARD SPECIFICATIONS SECTION 9-30.1.(1). SIX-INCH FIRE HYDRANT SPOOLS SHALL BE CLASS 52. GATE VALVES SHALL BE RESILIENT WEDGE, NRS (NON RISING STEM) WITH O-RINGS SEALS. VALVE ENDS SHALL BE MECHANICAL JOINT OR ANSI FLANGES. VALVES SHALL CONFORM TO AWWA 509-80. VALVES SHALL BE MUELLER, M & H, KENNEDY, CLOW R/W OR WATEROUS SERIES 500. EXISTING VALVES TO BE OPERATED BY CITY EMPLOYEES ONLY. HYDRANTS SHALL BE M & H RELIANT STYLE 929 OR 129, MUELLER CENTURION, OR CLOW MEDALLION. HYDRANTS SHALL BE BAGGED UNTIL SYSTEM IS APPROVED. SEE DETAIL 6-7 SHEET 24. ALL LINES SHALL BE CHLORINATED AND TESTED IN CONFORMANCE WITH THE ABOVE REFERENCED SPECIFICATION (NOTE 1). ALL PIPE AND SERVICES SHALL BE INSTALLED WITH CONTINUOUS TRACER TAPE INSTALLED 12" TO 18" UNDER THE FINAL GROUND SURFACE. THE MARKER SHALL BE PLASTIC NON-BIODEGRADABLE, METAL CORE OR BACKING MARKED WATER 2-INCH-WIDE MINIMUM, WHICH CAN BE DETECTED BY A STANDARD METAL DETECTOR. TAPE SHALL BE TERRA TAPE "D" OR APPROVED EQUAL. IN ADDITION TO TRACER TAPE, INSTALL 14 GAUGE HEAVY DUTY DIRECT BURY COATED COPPER WIRE (PAIGE "UF" SINGLE CONDUCTOR OR EQUAL), WRAPPED AROUND THE PIPE, BROUGHT UP AND TIED OFF AT VALVE BODY ALL WIRE CONNECTIONS SHALL USE WIRE NUTS AND A DBR SPLICE KIT, MANUFACTURED BY 3-M OR APPROVED EQUAL. ALL LOCATOR WIRE FOR SERVICE PIPE SHALL BE CONNECTED TO THE LOCATOR WIRE ON THE WATER MAIN. PROVIDE TRAFFIC CONTROL PLAN(S) AS REQUIRED IN ACCORDANCE WITH MUTCD. ALL WATER MAINS SHALL BE STAKED FOR GRADES AND ALIGNMENT BY AN ENGINEERING OR SURVEYING FIRM CAPABLE OF PERFORMING SUCH WORK. ALL SERVICE LINE LOCATIONS SHALL BE MARKED ON THE FACE OF THE CURB WITH AN EMBOSSED "W" 1/4 INCH INTO CONCRETE. CALL UNDERGROUND LOCATE AT 1-800-424-5555 A MINIMUM OF 48 HOURS PRIOR TO ANY EXCAVATIONS. THE CITY WILL BE GIVEN 72 HOURS NOTICE PRIOR TO SCHEDULING A SHUTDOWN. WHERE CONNECTIONS REQUIRE "FIELD VERIFICATION", CONNECTION POINTS WILL BE EXPOSED BY CONTRACTOR AND FITTINGS VERIFIED 48 HOURS PRIOR TO DISTRIBUTING SHUT-DOWN NOTICES. AT ANY CONNECTION TO AN EXISTING LINE WHERE A NEW VALVE IS NOT INSTALLED, THE EXISTING VALVE MUST BE PRESSURE TESTED TO CITY STANDARDS PRIOR TO CONNECTION. IF AN EXISTING VALVE FAILS TO PASS THE TEST, THE CONTRACTOR SHALL MAKE THE NECESSARY PROVISIONS TO TEST THE NEW LINE PRIOR TO CONNECTION TO THE EXISTING SYSTEM OR INSTALL A NEW VALVE. AFTER COMPLETION OF ALL ITEMS SHOWN ON THESE PLANS AND BEFORE ACCEPTANCE OF THE PROJECT, THE CONTRACTOR SHALL OBTAIN A "PUNCH LIST" PREPARED BY THE CITY'S INSPECTOR DETAILING REMAINING ITEMS OF WORK TO BE COMPLETED. ALL ITEMS OF WORK SHOWN ON THESE PLANS SHALL BE COMPLETED TO THE SATISFACTION OF THE CITY PRIOR TO ACCEPTANCE OF THE WATER SYSTEM AND PROVISION OF SANITARY SEWER SERVICE. A COPY OF THESE APPROVED PLANS AND APPLICABLE CITY DEVELOPER SPECIFICATIONS AND DETAILS SHALL BE ONSITE DURING CONSTRUCTION. ANY REVISIONS MADE TO THESE PLANS MUST BE REVIEWED BY THE DEVELOPER'S ENGINEER AND THE CITY OF YELM PRIOR TO ANY IMPLEMENTATION IN THE FIELD. THE CITY SHALL NOT BE RESPONSIBLE FOR ANY ERRORS AND/OR OMISSIONS ON THESE PLANS. ALL LUMBER (PLYWOOD, ETC.) USED TO MOUNT EITHER PUMP CONTROL PANEL OR POWER METER MUST BE PRESSURE TREATED. INSPECTIONS FOR ONSITE STEP INSTALLATIONS ARE REQUIRED. A 24 HOUR NOTICE TO THE SEWER DEPARTMENT IS REQUIRED PRIOR TO THE INSPECTION. ITEMS NEEDING INSPECTION ARE: A)TANK INSTALLATION, IE; BEDDING AND LOCATION B)TANK INFILTRATION, EXFILTRATION TEST C)S.S. PRESSURE TEST D)SERVICE LINE PRESSURE TEST E)FINAL INSPECTION IN THE EVENT THAT THE DEPARTMENT OF LABOR AND INDUSTRIES OR THE CITY SHOULD REQUIRE A SEPARATE "ON-OFF" SWITCH CONTROLLING POWER TO THE PUMP CONTROL PANEL, SAID SWITCH MUST BE LOCKABLE OR HAVE A LOCKING COVER TO HOLD AN OLYMPUS TYPE BP125, 30MM PADLOCK. PUMP CONTROL PANELS SHALL BE LOCATED ON GARAGE WALL OR REMOTE POST, UNLESS OTHERWISE AUTHORIZED BY THE CITY OF YELM. PRIOR TO BACKFILL ALL MAINS AND APPURTENANCES SHALL BE INSPECTED AND APPROVED BY THE CITY OF YELM. APPROVAL SHALL NOT RELIEVE THE CONTRACTOR FOR CORRECTION OF ANY DEFICIENCIES AND/OR FAILURES AS DETERMINED BY SUBSEQUENT TESTING AND INSPECTIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE CITY OF YELM FOR THE REQUIRED INSPECTIONS. ALL STEP MAINS SHALL BE HYDROSTATICALLY TESTED IN CONFORMANCE WITH THE ABOVE-REFERENCED SPECIFICATION FOR TESTING WATER MAINS. (SEE NOTE 1.) IN ADDITION, ALL STEP MAINS SHALL BE PIGGED/CLEANED IN THE PRESENCE OF THE CITY INSPECTOR PRIOR TO PLACING STEP MAIN IN SERVICE. ANY CHANGES TO THE DESIGN SHALL FIRST BE REVIEWED AND APPROVED BY THE CITY OF YELM. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO HAVE A COPY OF THESE APPROVED PLANS ON CONSTRUCTION SITE AT ALL TIMES. PROVIDE TRAFFIC CONTROL PLAN(S) IN ACCORDANCE WITH THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) AS REQUIRED. EROSION CONTROL MEASURES SHALL BE TAKEN BY THE CONTRACTOR DURING CONSTRUCTION TO PREVENT INFILTRATION OF EXISTING AND PROPOSED STORM DRAINAGE FACILITIES AND ROADWAYS. TEMPORARY STREET PATCHING SHALL BE ALLOWED FOR AS APPROVED BY THE CITY ENGINEER. TEMPORARY STREET PATCHING SHALL BE PROVIDED BY PLACEMENT AND COMPACTION OF 2 INCH MINIMUM ASPHALT CONCRETE COLD MIX. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTENANCE AS REQUIRED. BEDDING OF THE SEWER MAIN AND COMPACTION OF THE BACKFILL MATERIAL SHALL BE REQUIRED IN ACCORDANCE WITH THE ABOVE MENTIONED SPECIFICATION (SEE NOTE 1). ALL BURIED POWER FOR STEP SYSTEMS SHALL BE INSTALLED WITH CONTINUOUS TRACER TAPE INSTALLED 12" ABOVE THE BURIED POWER. THE MARKER SHALL BE PLASTIC NON- BIODEGRADABLE, METAL CORE BACKING MARKED "POWER". TAPE SHALL BE FURNISHED BY CONTRACTOR. ALL PLASTIC PIPE AND SERVICES SHALL BE INSTALLED WITH CONTINUOUS TRACER TAPE INSTALLED 12" TO 18" UNDER THE PROPOSED FINISHED SUBGRADE. THE MARKER SHALL BE PLASTIC NON-BIODEGRADABLE, METAL CORE OR BACKING MARKED SEWER WHICH CAN BE DETECTED BY A STANDARD METAL DETECTOR. IN ADDITION, STEP SYSTEMS, AND FORCE MAINS SHALL BE INSTALLED WITH 14 GAUGE DIRECT-BURY RATED COPPER WIRE WRAPPED AROUND ALL PLASTIC PIPE, BROUGHT UP AND TIED OFF AT VALVE BODY. TAPE SHALL BE TERRA TAPE "D" OR APPROVED EQUAL. THE TAPE AND WIRE SHALL BE FURNISHED BY THE CONTRACTOR. SIDE SEWER SERVICES SHALL BE PVC, ASTM D 3034 SDR 35 WITH FLEXIBLE GASKETED OR SOLVENT WELD JOINTS. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE LOCATION AND PROTECTION OF ALL EXISTING UTILITIES. THE CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION BY CALLING THE UNDERGROUND LOCATE LINE AT 1-800- 424-5555 A MINIMUM OF 48 HOURS PRIOR TO ANY EXCAVATION. THE CITY OF YELM SHALL BE NOTIFIED A MINIMUM OF 48 HOURS IN ADVANCE OF A TAP CONNECTION TO AN EXISTING MAIN. A CITY REPRESENTATIVE SHALL BE PRESENT AT THE TIME OF THE TAP. A PRECONSTRUCTION MEETING SHALL BE HELD WITH THE CITY OF YELM PRIOR TO THE START OF CONSTRUCTION. IF CONSTRUCTION IS TO TAKE PLACE IN THE COUNTY RIGHT-OF-WAY, THE CONTRACTOR SHALL NOTIFY THE COUNTY AND OBTAIN ALL THE REQUIRED APPROVALS AND PERMITS. ALL APPROVALS AND PERMITS REQUIRED BY THE CITY OF YELM SHALL BE OBTAINED BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH CITY OF YELM STANDARDS AND THE MOST CURRENT COPY OF THE STATE OF WASHINGTON STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION (WSDOT/APWA). 22. 09/16/2019 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH DATE: June 28, 2018 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-UTIL-DETL.dwg UTILITY NOTES AND DETAILS C6.8 28 09/16/2019 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH DATE: June 28, 2018 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-UTIL-DETL.dwg UTILITY NOTES AND DETAILS C6.9 29 09/16/2019 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH DATE: June 28, 2018 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-UTIL-DETL.dwg UTILITY NOTES AND DETAILS C6.10 30 09/16/2019 9+5510+0011+0012+0013+0014+0015 + 0 0 16+00 17+00 18+00 19+00 20+00 21+00 22+00 23+00 24+00 25+0026+0027+0028+0029+0029+5030+0031+0032+0033+0034+0035+00 36+00 37+00 38+00 3 9 + 0 0 40+0041+0042+0043+0050+0051+0052+0053+0054+0054+2380+00 81+00 90+00 91+00 308+00309+00310+00311+00312+00313+00314+00PROPOSED LUMINAIRE (TYP) . . 2. . . .. . . .. . . .. . . .. . . .. 1 1 . 2 STA 81+51, 19' LT STA 30+43.5, 21.5' LT STA 53+80, 21.5' RT STA 50+36, 14' LT STA 42+68, 21.5' RT STA 91+00, 19' RT 1 2 1 3 3. 2. . STA 90+38, 19' RT . . . . . 2 STA 80+82, 19' LT KILLION ROAD'B' LOOP SE'B' LOOP SE'C' ROAD SE'E' ROAD SE 'A' ROAD SE 'B' ROAD SE 'D' ROAD SE 'A' ROAD SE'A' ROAD SEMOUNTAIN VIEW ROAD2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH DATE: June 13, 2018 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-SIGN-LIGHT.dwg SIGNING AND LIGHTING PLAN C7.0 31 LEGEND PROPOSED SIGN PROPOSED LUMINAIRE 42" X 6" 4"B 30" X 6" 4"B 42" X 6" 4"B 24" X 6" 4"B 30" X 6" 4"B 30" X 6" 4"B 45° 12" (TYP.) 8" TO 6" MIN. VARIES 20"20"5' MIN.TYPE III BARRICADE NOT TO SCALE 24" x 24" R1-1 TYPE IV SHEETING CONCRETE BASE WITH SLEEVE CONCRETE BASE, SIGN POST AND SIGN PLACEMENT SIGNS TO BE ATTACHED TO POST WITH A MINIMUM OF TWO FASTENERS 1" 1/2" 1/2" 2" 4' 1" 1" 1/2" 6' VARIES 0.125 ALUMINUM SIGN BLANK WHITE LETTERS ON GREEN BACKGROUND (NO BORDER) LETTER SERIES AS NOTED ON PLANS. SUPER ENGINEER GRADE (TYPE II) REFLECTIVE SHEETING TYPICAL STREET NAME SIGN NOT TO SCALE NOTE: ALL STREET SIGNS LETTERS TO BE SERIES B 1/2"R 24" x 30" 25 LIMIT SPEEDFUTURE STREET CONNECTION *CONTACT CITY FOR SIGN 30" X 6" 4"B STEEL SLEEVE 12 GAUGE GALVANIZED W/2.25"x2.25' CONCRETE BASE 8" DIA. 32" 6`2" 4" 7'-0" MIN 8'-0" MAX TO LOWEST SIGN FROM NEAREST EDGE OF PAVEMENT ± R2-1. . . .. . . . . .. . .. 1 2 3 INSTALL 2-16 BOX "CBU" MAILBOX CLUSTERS 1-12 BOX "CBU" MAILBOX CLUSTER CONTRACTOR TO COORDINATE WITH CITY OF YELM POSTMASTER INSTALL 2-16 BOX "CBU" MAILBOX CLUSTERS CONTRACTOR TO COORDINATE WITH CITY OF YELM POSTMASTER 1 2 N GRAPHIC SCALE 0 50 100 1" = 50 FEET 25 CONCRETE BASE W/2.25"x2.25' 12 GAUGE GALVANIZED STEEL SLEEVE W/ 3/8" DIA. PERFORATIONS 2"x2" O.D. 14 GAUGE GALVANIZED STEEL POST W/3/8" DIA. PERFORATIONS SIGNS SHOWN ONE SIDE ONLY GR OP NW UNTY R O A D C CRO S S R O A D STOP 24' TYPE III BARRICADE 24' TYPE III BARRICADE 09/16/2019 299+98 300+00 301+00 302+00 303+00 304+00 305+00 306+00 307+00BP: 299+98.28PC: 300+21.01PT: 300+74.71N39° 55' 57"E 22.73' N1° 28' 27"E 684.07' Δ=38°27'30" R=80.00' L=53.70'D D D D D D D CB #54 CB #55 CB #53 STCB#5217 TYPE 1 RIM:342.35 6" PVC NW IE:339.97 12' 12' 12' STA:301+37.01, 4.50'LT END WIDE LINE 344 343 343 343 343 343 344 16.5' 19.5' STA:301+84.21, 19.50'RT FACE OF CURB STA:301+84.20, 16.50'LT FACE OF CURB STA:303+24.18, 16.00'LT FACE OF CURB STA:303+24.18, 16.00'RT FACE OF CURBSTA:301+87.01, 7.50'RT BEGIN TAPER STA:303+97.01 END TAPER LT & RT END DOUBLE YELLOW 'C BEGIN SKIP 'C AND NO PASS LINE ON LEFT STA:302+57.01, 3.50'LT BEGIN DOUBLE YELLOW 'C BEGIN TAPER STA:304+22.78, 18.50'LT RELOCATE EXISTING WATER METER 16' 16' 16' 16'START PROJECTSTA 300+89.49325 330 335 340 345 350 355 300+00 300+50 301+00344.37344.24301+50344.12343.99302+00343.86343.74302+50343.61343.49303+00343.36343.24303+50343.19343.32304+00343.44343.57304+50343.69343.76305+00343.60343.43305+50343.26343.08306+00342.93343.09306+50343.35343.60307+00343.86343.93307+50343.80343.680.50%0.50%0.69%1.03% GRADE BREAK STA: 300+95.45 ELEV: 344.390 PVI: 343.15 PVI STA: 303+42.03 K: 24.89 25' VC BVCS: 303+29.53BVCE: 343.21EVCS: 303+54.53EVCE: 343.21LOW PT: 303+42.04ELEV: 343.18PVI: 342.88 PVI STA: 306+04.46 K: 14.54 25' VC BVCS: 305+91.96BVCE: 342.97EVCS: 306+16.96EVCE: 343.01LOW PT: 306+02.02ELEV: 342.93PVI: 343.80 PVI STA: 304+71.61 K: 20.94 25' VC BVCS: 304+59.11BVCE: 343.74EVCS: 304+84.11EVCE: 343.71HI PT: 304+69.61ELEV: 343.76PVI: 343.99 PVI STA: 307+12.50 K: 16.38 25' VC BVCS: 307+00.00BVCE: 343.86EVCS: 307+25.00EVCE: 343.93HI PT: 307+16.83ELEV: 343.95PROPOSED GRADE @ ROW CENTERLINE EXISTING GRADE @ ROW CENTERLINE EXISTING ELEVATION @ ROW CENTERLINE PROPOSED ELEVATION @ ROW CENTERLINE STA: 303+42.03, 14.92 L IE: 339.71 12" (E) RIM: 342.88 CB #55, CB TYPE 1 30 LF 12" CPEP STM @ 0.50% STA: 303+42.03, 14.92 R IE: 339.56 12" (W) IE: 339.23 12" (N) RIM: 342.88 CB #54, CB TYPE 1 262 LF 12" CPEP STM @ 0.50% STA: 306+04.31, 14.92 R IE: 337.92 12" (S) IE: 337.92 12" (N) RIM: 342.64 CB #53, CB TYPE 1 291 LF 12" CPEP STM @ 0.50% EXISTING 4" Ø S.T.E.P. SEWER MAIN EXISTING 8" Ø WATERMAIN 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH DATE: July 6, 2018 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-FRONTAGE.dwg MOUNTAIN VIEW ROAD OFFSITE IMPROVEMENTS C8.0 32 ADJUST VALVE BOX TO GRADE (TYP) NOTES 1 1 CONSTRUCT DROP CURB PER CEMENT CONCRETE APPROACH, MATCH EX DRIVEWAY WIDTH, CONTRACTOR TO REBUILD DRIVEWAY AS REQUIRED 2 START PROJECTSTA 300+89.492 2 2 MATCH LINE 307+50SEE SHEET C8.1MOUNTAIN VIEW ROAD & STORM PROFILE SCALE: H:1"=30', V:1"=5'NGRAPHIC SCALE 0 30 60 1" = 30 FEET 15 MATCH LINE 307+50SEE SHEET C8.1355 350 345 340 335 330 MOUNTAIN VIEW ROADYELM AVE / HWY 510 MATCH EXISTING CURB MATCH EXISTING CURB 325 EXISTING SIDEWALK TO REMAIN CONSTRUCT ROADWAY PER NEIGHBORHOOD COLLECTOR ON SHEET C3.1 EXISTING CB TO REMAIN EXISTING ROW EXISTING LUMINAIRE TO REMAIN 2 CONSTRUCT ASPHALT RAMP 12:1 MAX SLOPE 09/16/2019 308+00 309+00 310+00 311+00 312+00 313+00 314+00 315+00 316+00 PI: 307+58.78 PI: 314+17.88 N5° 39' 19"E 212.84' 80+00 81+00DD D D D DDDDDDD CB #50CB #48 CB #49 CB #52 CB #51 CB #6CB #7 N1° 53' 58"E 659.09' 343 343 344 344 343 342 341340339338337336 344 344 343 3423 4 3 34 2 34 1 341340339338337 40' EXISTING ROW 16' 16' STA:308+47.66, 31.00'LT END IMPROVEMENTS MOUNTAIN VIEW ROAD STA: 311+27.78 = ROAD "D" STA: 80+00.00 STA:314+17.88, 0.00'T END SKIP CENTERLINE AND NO PASS LINE BEGIN DOUBLE YELLOW CL AND BEGIN TAPER STA:314+17.88, 15.00'LT BEGIN TAPER BEGIN WHITE EDGE LINE 16' 16' CONSTRUCTION CL STA:316+21.67, 9.85'LT END TAPER END WHITE EDGE LINE STA:316+22.31, 0.00'T END DOUBLE YELLOW CL END TAPER STA:316+22.25, 9.86'RT END TAPER END WHITE EDGE LINE STA 311+27.78 (MT.VIEW RD)STA 80+00 ('D' ROAD) =PROPOSED 4"Ø SEWER PROPOSED 8"Ø WATERELEV=344.24325 330 335 340 345 350 355 307+50343.80343.68308+00343.55343.43308+50343.30343.18309+00343.12343.23309+50343.35343.48310+00343.60343.73310+50343.85343.98311+00344.10344.23311+50344.14343.91312+00343.68343.45312+50343.22342.99313+00342.76342.52313+50342.29342.05314+00341.67341.09314+50340.32339.37315+00338.37337.46315+50336.74336.20316+00335.860.50%0.50%0.92% 4.00% 1.00%GRADE BREAK STA: 316+21.61END OF PROJECTELEV: 335.640PVI: 343.08 PVI STA: 308+95.01 K: 25.03 25' VC BVCS: 308+82.51BVCE: 343.14EVCS: 309+07.51EVCE: 343.14LOW PT: 308+94.99ELEV: 343.11100' VC PVI: 336.35 PVI STA: 315+50.55 K: 33.32 BVCS: 315+00.55BVCE: 338.35EVCS: 316+00.55EVCE: 335.85PVI: 344.28 PVI STA: 311+35.01 K: 17.56 25' VC BVCS: 311+22.51BVCE: 344.22EVCS: 311+47.51EVCE: 344.16HI PT: 311+31.29ELEV: 344.24100' VC PVI: 341.67 PVI STA: 314+17.55 K: 32.51 BVCS: 313+67.55BVCE: 342.13EVCS: 314+67.54EVCE: 339.67PROPOSED CL GRADE EXISTING GRADE EXISTING ELEVATION @ ROW CENTERLINE PROPOSED ELEVATION @ ROW CENTERLINE STA: 308+95, 14.08 R IE: 336.47 12" (W) IE: 336.47 12" (S) IE: 336.47 12" (N) RIM: 342.83 CB #48 48" TYPE 2 CB 29 LF 12" CPEP STM @ 9.79% STA: 308+95, 14.92 L IE: 339.31 12" (E) RIM: 342.81 CB #49, CB TYPE 1 248 LF 12" CPEP STM @ 0.50% STA: 311+42.90, 14.08 R IE: 335.23 12" (E) IE: 335.23 12" (S) IE: 335.23 12" (N) RIM: 343.92 CB #50, 48" TYPE 2 CB 257 LF 12" CPEP STM @ 0.77% STA: 313+99.95, 14.92 R IE: 337.55 8" (W) IE: 337.22 12" (S) RIM: 341.37 CB #52, CB TYPE 1 30 LF 8" CPEP STM @ 0.50% STA: 314+00, 14.92 L IE: 337.70 8" (E) RIM: 341.37 CB #51, CB TYPE 1 EXISTING 4" Ø S.T.E.P. SEWER MAIN EXISTING 8" Ø WATERMAIN 291 LF 12" CPEP STM @ 0.50% EXISTING GRADE ALONG CONSTRUCTION CENTERLINE 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH DATE: July 6, 2018 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-FRONTAGE.dwg MOUNTAIN VIEW ROAD OFFSITE IMPROVEMENTS C8.1 33 PL RELOCATE EXISTING MAILBOXES RELOCATE EXISTING MAILBOX RELOCATE EXISTING MAILBOX RELOCATE EXISTING MAILBOX RELOCATE EXISTING MAILBOX CL ROW CONSTRUCT ASPHALT RAMP 12:1 MAX SLOPE CONSTRUCT ROADWAY PER NEIGHBORHOOD COLLECTOR, SEE SHEET C3.1 1 1 1 ADJUST VALVE BOX TO GRADE (TYP) STA 308+32.01,31.89 LT RELOCATE EXISTING FIRE HYDRANT R=15'R=15' STA 314+17.88, 15.00' RT BEGIN TAPER BEGIN WHITE EDGE LINE STA 310+82 TO 311+73 NO STRIPE308+22.66 31' LT 308+72.66 31' LT STA 316+21.61END PROJECTSEE SHEET C4.0 2 3 REMOVE EXISTING FENCE COORDINATE WITH OWNER 32 4 4 4 TELEPHONE PEDESTAL TO BE RELOCATED BY OTHERS RELOCATED EX BLOWOFF TV PEDESTAL TO BE RELOCATED BY OTHERS 2 2 2 4"25"#3 BAR EACH SIDE TOP AND BOTTOM NOTES 34" 24" 30 " 20 " 5" 5" 6" OR 12" ONE #3 BAR HOOP FOR 6" HEIGHT TWO #3 BAR HOOPS FOR 12" HEIGHT ALL METAL PIPE PIPE MATERIAL MAXIMUM INSIDE DIAMETER 15" 12" 12" 15" 15" 4" MI N. ( T Y P.) 26"(SEE N O T E 6) 22 " (S E E N O T E 6 ) #3 BAR EACH CORNER #3 BAR EACH CORNER 18" MIN. #3 BAR HOOP SEE NOTE 1 ONE #3 BAR ACROSS BOTTOM 1.As acceptable alternatives to the rebar shown in the PRECAST BASE SECTION, fibers (placed according to the Standard Specifications), or wire mesh having a minimum area of 0.12 square inches per foot shall be used with the minimum required rebar shown in the ALTERNATIVE PRECAST BASE SECTION. Wire mesh shall not be placed in the knockouts. 2.The knockout diameter shall not be greater than 18". Knockouts shall have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5" minimum gap between the knockout wall and the outside of the pipe. After the pipe is installed, fill the gap with joint mortar in accordance with Standard Specification 9-04.3. 3.The maximum depth from the finished grade to the lowest pipe invert shall be 5'. 4.The frame and grate may be installed with the flange up or down. The frame may be cast into the adjustment section. 5.The Precast Base Section may have a rounded floor, and the walls may be sloped at a rate of 1:24 or steeper. 6.The opening shall be measured at the top of the precast base section. 7.All pickup holes shall be grouted full after the inlet has been placed. PIPE ALLOWANCES WSDOT STD PLAN B-25.60-00MATCH LINE 307+50SEE SHEET C8.0MOUNTAIN VIEW ROAD & STORM PROFILE SCALE: H:1"=30', V:1"=5'MATCH LINE 307+50SEE SHEET C8.1355 350 345 340 335 330 NGRAPHIC SCALE 0 30 60 1" = 30 FEET 15 CONSTRUCT DROP CURB PER CEMENT CONCRETE APPROACH. MATCH EX DRIVEWAY WIDTH. CONTRACTOR TO REBUILD DRIVEWAY AS REQUIRED CONCRETE INLET PRECAST BASE SECTION RECTANGULAR ADJUSTMENT SECTION ALTERNATIVE PRECAST BASE SECTION FRAME AND VANED GRATE PROFILE WALL PVC (STD. SPEC. 9-05.12(2)) SOLID WALL PVC (STD. SPEC. 9-05.12(1)) CPSSP* (STD. SPEC. 9-05.20) REINFORCED OR PLAIN CONCRETE *CORRUGATED POLYETHYLENE STORM SEWER PIPE 325 NOTE: CONTRACTOR TO FIELD VERIFY LOCATION AND DEPTH OF EXISTING UTILITIES PRIOR TO CONSTRUCTION STA 308+25 TO 308+70 NO STRIPE SKIP CENTERLINE WITH NO PASS LINE ON LEFT SKIP CENTERLINE WITH NO PASS LINE ON LEFT 09/16/2019 XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X KILLION ROADMOUNTAIN VIEW ROAD"STOP"2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 34 STKTDSTDW/RI JULY 6, 2018 PERMIT SET 2180115.10 PHIL MITCHELL 910 TRAFFIC AVENUE SUMNER, WA 98390-9208 MITCHELL DEVELOPMENT II, LLC THE HUTCH Sec. 13, Twp. 17 N., Rge. 1 E., W.M. YELM, WASHINGTON THE HUTCH N GRAPHIC SCALE 0 50 100 1" = 50 FEET 25 DATE: July 2, 2018 FILENAME: Q:\2018\2180115\10_CIV\CAD\2180115-SH-EXST.dwg EXISTING CONDITIONS C9.0 34MATCHLINE AMATCHLINE A MATCHLINE BMATCHLINE B NN09/16/2019