Loading...
101137101 WORK SKETCH10508 10512 10503 CREEK ST SE65T O8816 10501 ESTIMATED FAULT AREA 65T O8816 CØ9164 SITE PLAN SCALE: 1:50 EXISTING UNDERGROUND MAP: # . SCALE: 1:100 1702E114 UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP N. COSME 253-569-6158 2/15/21 C. TOBIN 253-548-4516 2/15/21 N/A N/A N/A N. COSME 253-569-6158 2/15/21 N/A CITY OF YELM YEL-26 O#629624 CREW3 BO CABLE REPAIR 10503 CREEK ST SE, YELM, WA 98597 N/A N/A N/A 101137101 AS NOTED 1 OF 1 THURSTON N/A N/A QSTHLE NW-29-17-02 N/A N/A 1702E114 1702E116 1702E114 YEL-26 N/A N/A N/A N/A N/A N/A N/A N/A N/A Potelco, Inc.DESIGNED BY 101137101VAULT & EQUIPMENT TABLE SITE GRID NUMBER VAULT SIZE & COVER TYPE & SIZE EQUIPMENT IN VAULT PRIMARY BUSHINGS TRANSFORMER ID NUMBERS (COMPANY ID) REMARKS LB DC V01 559113 147818 EXISTING VAULT 50kVA PM XFMR 120/240v EXISTING -- TOTALS :-- SITE SPECIFIC NOTES -Locate fault by thumper method and mark fault area in white paint. -Remove damaged section of cable L________' -Install L________' 1/0 AL Str Bare CN PRI Splice (SPL10JX) to make repair on B/O UG AL 1/0 Primary CN Cable #9164-C -Foreman Note: Fault is located approx ______' north of (559113-147818) FOREMAN (CHECK BOX WHEN COMPLETED) #1 Print Name ___________________________________ Date ______________ PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Material VERIFIED and CHANGES noted on Paperwork. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures #1 Foreman's Signature _______________________________________________ and that all quality requirements are met. Field Changes RED-LINED on As-built. Total PRIMARY Cable noted on As-built. Correct QC Checklist(s) reviewed. #1 #2 #2 Print Name ___________________________________ Date ______________ #2 Foreman's Signature _______________________________________________ SCOPE OF WORK The general scope of this project is to make repair on b/o UG AL1/0 primary cables within the project area by the most economic means possible. Project type : Planned Project location : Number of Cables : 1 Cable Footage Estimated : 1' Cable Numbers Injected : 0 Cable Numbers Repaired : 9164 Cable Numbers Abandoned : 0 Cable Numbers Replaced : 0 There will be an advance notice provided by the contractor 24-hour advance notice of no parking in work areas. Access will be maintained to all residences and their driveways. When work is occurring directly in front of driveways, the contractor will work with the residence to manage access. Traffic Revisions Flagging crews will maintain one lane; flaggers will assist vehicles alternating through the roadway during work hours. For more information on the project 24-hour project information (888) 471-7339, (360) 825-5236 THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG No No No Yes Yes Yes"Locates Required" POTELCO DESIGN AND Signature _________________________________________ Print Name _________________________________________ This design complies with PSE Any/all variations have been Design/Engineering Standards. QUALITY ASSURANCE pre-approved/documented by the appropriate PSE Representative. Date _________________ JOB SITE MAKE NO CHANGES TO THIS JOB WITHOUT PRIOR APPROVAL Notify Customers and Service Area 48 HRS Prior To Planned Outages ORDER#NOTIF#PROJECT PHASE MAINTENENCE O & M SUPERIOR FAILED SILICONE REMOVAL EXPENSE 11747821 101137101 N/A N/A VICINITY MAP For contacts below dial 1-888-CALL PSE (225-5773) Contact Information CREW TO PROVIDE ALL PROPERTY OWNER'S THAT ARE IMPACTED BY PROJECT PRIOR NOTICE AND MAKE AN EFFORT TO WORK WITH PROPERTY OWNER'S TO MAINTAIN THEIR ACCESS TO THEIR PROPERTY, AS WELL AS, REDUCE THE IMPACT OF OUR WORK ON THEIR USE OF THEIR PROPERTY. WIRE CREW FOREMAN NOTE: ALL FAULT INDICATORS WILL BE MAINTAINED IN THEIR CURRENT LOCATION ON 1/0 CABLES AFTER NEW CABLE IS INSTALLED UNLESS OTHERWISE SPECIFIED. PLEASE RED-MARK ALL FAULT INDICATORS ON "CABLE DIAGRAM" FOR MAPPING. CIVIL CREW FOREMAN NOTE: MAINTAIN ON SITE, IN GOOD CONDITION, A COMPLETE FILE OF ALL WORK DRAWINGS. THESE DRAWINGS SHALL BE AVAILABLE AT ALL TIMES TO A PUGET SOUND ENERGY REPRESENTATIVE. CORRECTIONS AND CHANGES MADE DURING THE JOB SHALL BE RECORDED CONTINUOUSLY ON THESE DRAWINGS. FURNISH PUGET SOUND ENERGY A COMPLETE SET OF AS-BUILT PRINTS (FOREMAN'S COPIES) AT THE END OF THE JOB. FOREMAN NOTE: CALL (800) 424-5555 UTILITY NOTIFICATION CENTER 24/7 BEFORE BEGINNING ANY EXCAVATION PREVENTS DAMAGE TO UNDERGROUND FACILITIES, SERVICE INTERRUPTIONS & BODILY INJURY. 10503 CREEK ST SE, YELM, WA 98597 253-569-6158 NIGEL_COSME "Flagging Required" "Outages Required" PRIMARY CABLE & CONDUIT TABLE LOCATION PRIMARY CABLE REMARKS FROM TO CABLE SIZE DESIGN LENGTH (ft) ACTUAL LENGTH (ft) CABLE NUMBERS PLEASE RECORD FOREMAN - COMPLETE A B C MANUFACTURER COMPOUND YEAR P01 V01 1/0 AL JKT 1 --9164 TOTAL 2"1 1216_140TH_AVE_CT_E_SUMNER