Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2021.0018 4234_Popeyes Yelm Envelope Compliance - 24mar21
Administered by: ©2021 NEEA, All rights reserved Date: Mar 24, 2021 ENVELOPE COMPLIANCE SUMMARY 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all R1 Project & Applicant Information Project Title Popeyes Yelm - 2018 WSEC For Building Department Use: Project Address 1405 Yelm Ave East (SR 510) Yelm, WA 98597 Applicant Name Joshua Ensley Applicant Phone 360-863-6677 Applicant Email josh.e@renschengineering.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Dining, Restaurant Building Cond. Floor Area 2,333 Project Scope New Building Space Conditioning Categories Fully Conditioned Walk-in Cooler Walk-in Freezer Project Cond. Floor Area 2,333 Floors Above Grade 1 Compliance Method Compliance Method 1 - General Envelope Project Description New single-story restaurant with exterior walk-in cooler/freezer Envelope Compliance Scope and Method Scope Space Conditioning Category Compliance Method WWR/SRR per Category UA Calculation Adjustment Fenestration Alternates Compliance Verification New Building Walk-in Cooler Prescriptive NA No Calculation Adjustments allowed NA COMPLIES New Building Walk-in Freezer Prescriptive NA No Calculation Adjustments allowed NA COMPLIES New Building Fully Conditioned Prescriptive 13.11% / 0% None selected No alternates selected COMPLIES Air Barrier Testing Air barrier testing included in project scope Air Barrier Comments Project Title Popeyes Yelm - 2018 WSEC Date Mar 24, 2021 Scope & Space Conditioning NEW BUILDING - WALK-IN COOLER Compliance Verification COMPLIES Window-to-wall Ratio NA Skylight-to-roof-ratio NA Vertical Fenestration Alternate NA Opaque Envelope Assemblies Insulation R-Values Roof/Ceiling Location in Documents Assembly ID Assembly Location Cavity Continuous (% penetration) 2nd Layer (MB Roof)U-Factor Net Area (SF) Walk-in cooler ceiling A14 N/A Interior partition R-25 (< 0.04%) 109 Envelope assembly type: Site-assembled steel-framed U-Factor Source: U-Factor Source Description: Walls Location in Documents Assembly ID Assembly Location Cavity Continuous (% penetration) Insulated Wall Furring U-Factor Net Area (SF) Walk-in cooler wall A14 N/A Interior partition R-25 (< 0.04%) 258 Envelope assembly type: Site-assembled steel-framed U-Factor Source: U-Factor Source Description: Slab-on-grade Floors Location in Documents Assembly ID Assembly Location Slab Edge Under Slab F-Factor Perimeter Length (SF) Unheated slab A14, Detail #9 N/A At grade level R-10 42 F-Factor Source Description: F-Factor Source: Slab Insulation Method: 2 ft vertical (from top of slab downward) Fenestration & Opaque Door Assemblies Insulation R-Values Opaque Doors Location in Documents Assembly ID Assembly Location Door Insulation U-Factor Rough Opening (SF) Walk-in cooler door A14 N/A Interior partition R-25 18 U-Factor Source: U-Factor Source Description: Does opaque cooler door have glazing?: No Project Title Popeyes Yelm - 2018 WSEC Date Mar 24, 2021 Scope & Space Conditioning NEW BUILDING - WALK-IN FREEZER Compliance Verification COMPLIES Window-to-wall Ratio NA Skylight-to-roof-ratio NA Vertical Fenestration Alternate NA Opaque Envelope Assemblies Insulation R-Values Roof/Ceiling Location in Documents Assembly ID Assembly Location Cavity Continuous (% penetration) 2nd Layer (MB Roof)U-Factor Net Area (SF) Firefox 1 Walk-in freezer ceiling A14 N/A Interior partition R-32 (< 0.04%) 59 Envelope assembly type: U-Factor Source: U-Factor Source Description: Walls Location in Documents Assembly ID Assembly Location Cavity Continuous (% penetration) Insulated Wall Furring U-Factor Net Area (SF) Walk-in freezer wall A14 N/A Interior partition R-32 (< 0.04%) 207 Envelope assembly type: Site-assembled steel-framed U-Factor Source: U-Factor Source Description: Floors and Edges Location in Documents Assembly ID Assembly Location Cavity Continuous (% penetration)U-Factor Net Area (SF) Walk-in freezer integral floor A14 N/A Interior partition R-28 (< 0.04%) 59 U-Factor Source: U-Factor Source Description: Fenestration & Opaque Door Assemblies Insulation R-Values Opaque Doors Location in Documents Assembly ID Assembly Location Door Insulation U-Factor Rough Opening (SF) Walk-in freezer door A14 N/A Interior partition R-32 18 U-Factor Source: U-Factor Source Description: Does opaque freezer door have glazing?: No Project Title Popeyes Yelm - 2018 WSEC Date Mar 24, 2021 Scope & Space Conditioning NEW BUILDING - FULLY CONDITIONED Compliance Verification COMPLIES Window-to-wall Ratio 13.11%Skylight-to-roof-ratio 0%Vertical Fenestration Alternate No alternates selected Opaque Envelope Assemblies Insulation R-Values Roof/Ceiling Location in Documents Assembly ID Assembly Location Cavity Continuous (% penetration) 2nd Layer (MB Roof)U-Factor Net Area (SF) Insulation entirely above deck A8 N/A Exterior R-53 (> 0.08% - 0.12%)2,057 U-Factor Source: U-Factor Source Description: Walls Location in Documents Assembly ID Assembly Location Cavity Continuous (% penetration) Insulated Wall Furring U-Factor Net Area (SF) Wood-framed and other - Commercial A8 N/A Exterior R-21 R-0 (< 0.04%) 2,658 Which insulation code target does wall comply with?: R-21 Cavity + Intermediate Framing U-Factor Source: U-Factor Source Description: Wall Framing Type (Standard, Inter., Advanced): Intermediate Framing Depth: 2x6 Framing Spacing: 16" o/c Slab-on-grade Floors Location in Documents Assembly ID Assembly Location Slab Edge Under Slab F-Factor Perimeter Length (SF) Unheated slab A8 N/A At grade level R-10 218 F-Factor Source Description: F-Factor Source: Slab Insulation Method: 2 ft vertical (from top of slab downward) Fenestration & Opaque Door Assemblies Insulation R-Values Opaque Doors Location in Documents Assembly ID Assembly Location Door Insulation U-Factor Rough Opening (SF) Swinging A17, Detail #1 Type B Exterior U-0.37 26 What percentage of this opaque door is glazing?: 50% or less U-Factor Source: U-Factor Source Description: Is this a public entrance door?: No Vertical Fenestration Location in Documents Assembly ID Assembly Location Orientation Shading (PF) Fenestration SHGC Fenestration U-Factor Rough Opening (SF) Fixed A17, Detail #3 B Exterior South/East/West Facing 0.2 ≤ PF < 0.5 SHGC-0.46 U-0.38 68 U-Factor & SHGC Source: U-Factor Source Description: Fixed A17, Detail #3 A Exterior North Facing 0.2 ≤ PF < 0.5 SHGC-0.56 U-0.38 99 U-Factor & SHGC Source: U-Factor Source Description: Fixed A17, Detail #3 B Exterior South/East/West Facing 0.2 ≤ PF < 0.5 SHGC-0.46 U-0.38 68 U-Factor & SHGC Source: U-Factor Source Description: Fixed A17, Detail #3 E Exterior South/East/West Facing PF < 0.2 SHGC-0.38 U-0.38 5 U-Factor & SHGC Source: U-Factor Source Description: Fixed A17, Detail #3 C Exterior South/East/West Facing PF < 0.2 SHGC-0.38 U-0.38 35 U-Factor & SHGC Source: U-Factor Source Description: Firefox 2 Fixed A17, Detail #3 D Exterior South/East/West Facing PF ≥ 0.5 SHGC-0.61 U-0.38 14 U-Factor & SHGC Source: U-Factor Source Description: Fixed A17, Detail #3 D Exterior North Facing PF ≥ 0.5 SHGC-0.61 U-0.38 7 U-Factor & SHGC Source: U-Factor Source Description: Operable A17, Detail #3 F Exterior South/East/West Facing PF ≥ 0.5 SHGC-0.38 U-0.40 20 U-Factor & SHGC Source: U-Factor Source Description: Operable A17, Detail #3 F Exterior South/East/West Facing PF ≥ 0.5 SHGC-0.61 U-0.40 20 U-Factor & SHGC Source: U-Factor Source Description: Glazed Doors Location in Documents Assembly ID Assembly Location Orientation Shading (PF) Fenestration SHGC Fenestration U-Factor Rough Opening (SF) Swinging entrance door A17, Detail #1 Type A Exterior South/East/West Facing 0.2 ≤ PF < 0.5 SHGC-0.46 U-0.60 45 U-Factor & SHGC Source: U-Factor Source Description: Is this a public entrance door?: Yes Door enclosed within a vestibule?: No vestibule Swinging entrance door A17, Detail #1 Type A Exterior North Facing PF < 0.2 SHGC-0.51 U-0.60 24 U-Factor & SHGC Source: U-Factor Source Description: Is this a public entrance door?: Yes Door enclosed within a vestibule?: No vestibule Firefox 3