2021.0018 Yelm Popeyes Mechanical Energy COMPLIANCE 2-12-212/12/2021 https://waenergycodes.com/print_project_summary_form.php?k=Y29tYm9fdGZ2X3BOPW11Y19odmFjX3N5c196b25pbmdfc2luZ2xIJTdDcGRfbmV3X2J1aWxkaW5nJnRmdjltZWNfaHZhY1...
IMECHANICALTUMIFLIANCE SUMMAR
2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all Rl Administered by: 02021 NEEA, All rights reserved
Project & Applicant
Information
Project Title Popeyes Yelm - 2018 WSEC
For Building Department Use: I Date: Feb 12, 2021
Project Address 1405 Yelm Ave East (SR 510)
Yelm, WA 98597
Applicant Name Joshua Ensley
Applicant Phone 360-863-6677
Applicant Email josh.e@renschengineering.com
For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com
General Occupancy
All Commercial
General Building Use Type
Dining, Restaurant
Building Cond. Floor Area 2,333
General Project Types
New Building
New Building
or Addition
Mechanical Scope
Single Zone Systems & Equipment
Alteratio
Mechanicn
al Scope
Project Cond. Floor Area 2,333
Floors Above Grade 1
Compliance Method Compliance Method 1 - General
Mechanical Project Description
New construction. Three (3) gas packaged rooftop units shall condition the space and provide make up ventilation air. Two (2) Type I hoods. The Type I hoods shall each be served by a utility
set grease exhaust fan on the roof for a total of three (3) grease exhaust fans. One (1) roof mounted exhaust fan shall exhaust the restrooms.
Scope & Space Conditioning W BUILDING - SINGLE ZONE SYSTEMS & EQUIP Compliance Verification COMPLIES
Single Zone Equipment Category - Condensing Unit
Equipment Summary Information
System/Equip ID Quantity of Items
RTU -1
RTU -2 & 3
Air Systems & Equipment - Cooling
Project Type
Economizer DOAS Ventilation
Mechanical Scope Exception(s)
Higher Equipment
Equipment Efficiency
Mechanical Compliance
Cooling Capacity
per item (Btu/h)
Provided?
Applied?
Efficient Option Applied?
y p pp
Compliance Verification
p
Scope and Method
New Building
Single Zone Systems & Equipment No No
NA
COMPLIES
RTU -1 Condensing unit, air cooled
New Building
No No
NA
RUN COMPLIANCE
Additional Efficiency
Units
Verification
Options Included (REPO)
Multiplier
Scope & Space Conditioning W BUILDING - SINGLE ZONE SYSTEMS & EQUIP Compliance Verification COMPLIES
Single Zone Equipment Category - Condensing Unit
Equipment Summary Information
System/Equip ID Quantity of Items
RTU -1
RTU -2 & 3
Air Systems & Equipment - Cooling
System
Heating System/Equip
Specific Type
Heat Pump Heating Capacity
System/
Equip ID Cooling System/Equip Type Specific Type
Cooling Capacity
per item (Btu/h)
AEPO Efficiency
Multiplier
Econo Exception Combined Efficiency
Multiplier (FL & PL) Multiplier (AEPO & Econo)
Proposed Cooling CE Proposed Part PL Efficiency Compliance
Efficiency Units Load Efficiency Units Verification
RTU -2 & 3 Condensing unit, air cooled
91,000
1
1 0
NA IEER COMPLIES
RTU -1 Condensing unit, air cooled
118,800
1
1 0
NA IEER COMPLIES
Air Systems & Equipment - Heating
System
Heating System/Equip
Specific Type
Heat Pump Heating Capacity
Cooling Capacity
AEPO
Efficiency
Proposed Heat
Pump
HPH
Proposed Low
OSA
LTH
Efficiency Compliance
/Equip ID
Type
(Btu/h)
(Btu/h)
Efficiency
Heating Efficiency
Units
Temp Efficiency
Units
Verification
Multiplier
RTU -1
Furnace
Warm,�j fired
1
COMPLIES
RTU -2 &
Furnace
Warm air, gas fired
1
COMPLIES
3
(AFUE)
Equipment Details
System/Equip ID Area(s) Served
Location In Project Documents - Plan/Detail #
RTU -1 Seating
Ml &M2
I i i i
https://waenergycodes.com/print_project_summary_form.php?k=Y29tYm9fdGZ2X3 BOP W 1 IY 19od m FjX3N5cl 96b25pbmdfc2luZ2xIJTd DcGRfbmV3X2J 1 aWxkaW5nJnRmdj 1 tZWNfaHZhY19zeXNfem9u ... 1/2
2/12/2021 https://waenergycodes.com/print_project_summary_form.php?k=Y29tYm9fdGZ2X3BOPW11Y19odmFjX3N5c196b25pbmdfc2luZ2xIJTdDcGRfbmV3X2J1aWxkaWSnJnRmdjltZWNfaHZhY1...
System/Equip ID for a single or multiple items?: Single item
WSEC Equip Efficiency Reference Table - Cooling: Table C403.3.2(1)A - Unitary Air Conditioners & Condensing Units
WSEC Equip Efficiency Reference Table - Heating: Table C403.3.2(4) Warm Air Furnaces
RTU -2 & 3 Kitchen I Ml & M2
System/Equip ID for a single or multiple items?: Multiple items w/ identical heating & cooling capacity
WSEC Equip Efficiency Reference Table - Cooling: Table C403.3.2(1)A - Unitary Air Conditioners & Condensing Units
WSEC Equip Efficiency Reference Table - Heating: Table C403.3.2(4) Warm Air Furnaces
Scope & Space Conditionin Compliance Verification RUN COMPLIANCE
https://waenergycodes.com/print_project_summary_form.php?k=Y29tYm9fdGZ2X3 BOP W 1 IY 19od m FjX3N5cl 96b25pbmdfc2luZ2xIJTd DcGRfbmV3X2J 1 aWxkaWSnJnRmdj 1 tZWNfaHZhY19zeXNfem9u ... 2/2