2021.0162.FR0007 FS-2_ KITCHEN ELECTRICAL ROUGH-INS PLAN Rev.0 markup8C7JSEE NOTE "A"THIS SHEET5355554952JSEE NOTE "A"THIS SHEETJ03J0590015172090123232425LEDLED4343JJ36JJ3638313328FVERIFY LOCATIONW/ FIRE PROTECTIONENGINEER / CODEFAN AND LIGHT SWITCH LOCATION BY ELECTRICAL DIVISION.901LIMIT SWITCHJ29LTYPICAL COLD STORAGE ROOMS ELEC. DIAGRAM5HEATED VACUUM VENTC.S.R. -COLD STORAGE ROOMEMT RIGID CONDUIT RUN ABOVE C.S.R. CEILING BY ELEC. DIVISION (TYP).2JREFER TO REFRIGERATOR SCHEMATIC ABOVE FOR ADDITIONAL CALL-OUTS.FREEZERSJJS3P4PSAKW HIGH TEMP. ALARM (WHEN SPECIFIED)ST*LDRAIN LINE HEATER CABLELVIEW PORT & DOOR HEATER CABLEHIGH TEMP. ALARM (WHEN SPECIFIED)120 V. ABOVE COLD STORAGE ROOM CEILINGKW LIGHTS (EACH)KW VIEW PORT & DOOR HEATER (FREEZER).2.4REFRIGERATOR1. LIGHT FIXTURES, SWITCH BOXES, SWITCHES, & SPLICE BOXES ARE FURNISHED LOOSE WITH COLD STORAGE ROOMS. ELECTRICAL DIVISION TO INSTALL ALL ITEMS FURNISHED LOOSE INCLUDING ALL INTERCONNECTING CONDUIT & WIRING.2. EVAPORATORS FOR COLD STORAGE ROOM ARE FURNISHED & INSTALLED COMPLETE WITH ROOM THERMOSTAT, LIQUID LINE SOLENOID & DISCONNECT SWITCH. ELECTRICAL DIVISION TO PROVIDE INTERCONNECTING CONDUIT & WIRING FORM BUILDING SERVICE TO ALL COMPONENTS.3. ELECTRICAL DIVISION TO PROVIDE ALL BUILDING SERVICES INCLUDING J-BOXES INTERCONNECTING CONDUIT & WIRING FROM BUILDING SERVICE TO COMPONENTS.4. EYS FITTING FURNISHED WITH COLD STORAGE ROOMS. ELECTRICAL DIVISION TO INSTALL, WIRE & SEAL BY ACCEPTED INDUSTRY PRACTICE.5. STAINLESS STEEL ESCUTCHEON PLATES & HOLES THROUGH INSULATED PANELS ARE FURNISHED WITH COLD STORAGE ROOM. ELECTRICAL DIVISION TO SEAL ALL PENETRATIONS WITH CAULKING ON THE C.S.R. INTERIOR & EXTERIOR AND INSTALL INTERIOR & EXTERIOR ESCUTCHEON PLATES.6. EVAPORATOR FAN MOTORS FOR REFRIGERATORS RUN CONTINUOUSLY. DO NOT WIRE INTERNALLY WITH THERMOSTAT. EVAPORATOR FAN MOTORS FOR FREEZERS CYCLE WITH FREEZER DEFROST.120 V. ABOVE C.S.R. CEILING VERIFYKW EVAPORATOR MOTORSJTS*EXTEND CONDUIT TO LIGHTS AS REQUIRED. SEE PLAN FOR QUANTITYANOTES:INTERIOR/ EXTERIOR LIGHT SWITCHJ*THERMOSTATJUNCTION BOXEYS & NIPPLE FOR CEILING PENETRATION TO SPLICE BOXLIQUID LINE SOLENOIDSVAPOR PROOF LIGHT FIXTUREEVAPORATORJTSLJSS208V ABOVE COLD STORAGE ROOMCEILING. VERIFY KW EVAPORATORMOTORSALL WALL MOUNT ELECTRICAL RECEPTACLE AND J-BOXES ARE TO BE FLUSH MOUNTED IN WALLS WITH NO EXPOSED CONDUIT SHOWING ON SURFACE OF WALLS. ARCHITECT TO PROVIDE MINIMUM WALL FURRING IF REQUIRED.NOTE120V, 1 PHASE, SERVICE, 10.0 AMPS, STUB AS NOTED, FOR POS/PRE-CHECK SYSTEM STATIONS. (DEDICATED CIRCUIT, ISOLATED GROUND, ADD PHONE LINE, PROVIDE EMPTY J-BOX WITH CONDUIT FOR INTERCONNECTING POS SYSTEM, PRE-CHECK AND PRINTERS) (VERIFY ALL REQUIREMENTS WITH POS SYSTEM SUPPLIER.)NOTE "A"1. ELECTRICAL PLAN SHOWS ROUGH-IN POINTS AND SCHEDULED CONNECTIONS. KITCHEN EQUIPMENT CONTRACTOR WILL PROVIDE DIMENSIONED ROUGH-IN DRAWINGS FOR CONSTRUCTION.2. ELECTRICAL SYSTEM IS DESIGNED FOR 120/208VOLTS, 1 & 3PHASE, 60HERTZ, 4 WIRE SYSTEM. 3. ELECTRICAL DIVISION SHALL FURNISH AND INSTALL ALL JUNCTION BOXES, RECEPTACLES, COVER PLATES, PULL BOXES, CONDUIT AND WIRING EXCEPT WHERE NOTED. RECEPTACLES AND COVER PLATES SHALL BE BRUSHED STAINLESS STEEL FURNISHED BY ELECTRICAL DIVISION. 4. KITCHEN EQUIPMENT CONTRACTOR SHALL FURNISH AND INSTALL ALL ELECTRICAL FOR FABRICATED COUNTERS AS NOTED COMPLETE WITH JUNCTION BOXES, CONDUIT, SURFACE MOUNTED ELECTRICAL BOXES, RECEPTACLES, COVER PLATES, ELECTRICAL RACEWAYS, CIRCUIT BREAKER PANEL AND WIRING. ELECTRICAL DIVISION TO MAKE FINAL CONNECTION.5. KITCHEN EQUIPMENT CONTRACTOR SHALL FURNISH AND INSTALL VAPOR PROOF VENTILATOR LIGHTS COMPLETE WITH LAMPS. INTERCONNECTING CONDUIT, WIRING WITH WALL SWITCH FURNISHED AND INSTALLED BY THE ELECTRICAL DIVISION.6. ADDITIONAL CONVENIENCE RECEPTACLES, TELEPHONE AND INTERCOM JACKS AND TEMPERATURE MONITORING SYSTEM ETC.. SHALL BE LOCATED BY THE ELECTRICAL ENGINEER/ ARCHITECT AND AS REQUIRED BY CODE.7. KITCHEN EQUIPMENT CONTRACTOR SHALL FURNISH DISPOSER CONTROLS. ELECTRICAL DIVISION SHALL FURNISH AND INSTALL INTERCONNECTING CONDUIT AND WIRE BETWEEN SWITCH, DISPOSER AND COMPONENTS.8. ELECTRICAL DIVISION SHALL FURNISH AND INSTALL ALL INTERCONNECTING CONDUIT AND WIRING BETWEEN MICRO-SWITCH AND SOLENOID FUEL SHUT OFF VALVE FURNISHED WITH FIRE SUPPRESSION SYSTEM SUPPLIED BY THE KITCHEN EQUIPMENT CONTRACTOR.9. PRE-FABRICATED COLD STORAGE ROOMS ARE FURNISHED BY THE KITCHEN EQUIPMENT CONTRACTOR COMPLETE WITH SPLICE BOXES, LIGHT FIXTURES, LAMPS, LIGHT SWITCHES AND DOOR HEATERS. ELECTRICAL DIVISION TO INSTALL SAME AND SHALL FURNISH AND INSTALL INTERCONNECTING CONDUIT, WIRING SEALOFFS, SEALANT AND MAKE FINAL CONNECTIONS.10. ELECTRICAL DIVISION SHALL FURNISH AND INSTALL ALL INTERCONNECTING CONDUIT AND WIRING BETWEEN KITCHEN EQUIPMENT CONTRACTOR FURNISHED LOW TEMP COLD STORAGE ROOM EVAPORATOR TERMINAL BLOCK, SWITCH, FAN DOOR SWITCH AND COMPRESSOR CONTROL PANEL.11. ELECTRICAL DIVISION SHALL FURNISH AND INSTALL EMPTY CONDUIT WITH JUNCTION BOXES FOR INSTALLATION OF OWNER SUPPLIED I.T. EQUIPMENT INCLUDING POS/ ELECTRONIC CASH CONTROL SYSTEM. ELECTRICAL DIVISION TO VERIFY INSTALLATION IN ACCORDANCE WITH OWNER'S REQUIREMENTS AND MANUFACTURER'S INSTRUCTIONS.12. ELECTRICAL DIVISION SHALL FURNISH AND INSTALL DISCONNECTS FOR ALL ELECTRICAL EQUIPMENT UNDER HOOD ACTIVATED BY FIRE SUPPRESSION SYSTEM.ELECTRICAL NOTESFSJFIXTURE MOUNTED JUNCTION BOXFIXTURE MOUNTED RECEPTACLEFLUORESCENT LIGHT FIXTUREFIELD WIRING RUNSINCANDESCENT LIGHT FIXTUREFIXTURE MOUNTED ELECTRICAL PANEL(2) DUPLEX RECT., 120-V, EMPTY JBOX WITH CONDUIT INTERCONNECTING P.O.E. PRE-CHECK & PRINTERS, ADD PHONE LINEFIRE SUPPRESSION MANUAL PULL STATION EMPTY JBOX WITH 15mm CONDUIT RUN IN WALL UP THRU CEILING TO ATTIC SPACEELECTRICAL CONDUIT, STUB AS INDICATED FOR DIRECT CONNECTIONJUNCTION BOX, HORIZONTAL MOUNTEDSWITCHELECTRICAL SYMBOLSDUPLEX RECT., 20-AMP, 120-VOLT, GROUND TYPE, HORIZONTAL MOUNTEDSIMPLEX RECT., 20-AMP, 120-VOLT, GROUND TYPE, HORIZONTAL MOUNTEDSPECIAL PURPOSE OUTLET, VOLTAGE AS INDICATED, GROUND TYPE, HORIZONTAL MOUNTEDFLJEJFLOOR/CEILING RECEPTACLE AS INDICATEDALL CONDUIT SHALL BE RUN ON THE EXTERIOR CEILING OF ALL COLD STORAGE ROOMS AND SHALL PENETRATE THE CEILING AT A POINT WHERE THE CONDUIT CAN DROP DIRECTLY TO THE POINT OF CONNECTION. UNDER NO CIRCUMSTANCES, WILL ELECTRICAL CONDUIT BE PERMITTED ON THE INTERIOR.NOTE: WALK-IN ELECTRICALC O N V E N I E N C E O U T L E T R E Q U I R E M E N T SITEMDESCRIPTIONVOLTSPHAMPSELEC TYPEAFFELECTRICAL COMMENTS900CONVENIENCE RECEPTACLE120115.0REC18"CONVENIENCE OUTLET STUB OUT WALL901CONVENIENCE RECEPTACLE120115.0REC48"CONVENIENCE OUTLET STUB OUT WALL902CONVENIENCE RECEPTACLE120115.0RECSTUB DOWN DROP CORD BY ELECTRICAL DIVISIONSHEETPROJECTBCRA NO.DATEREVISIONSSHEET TITLE© COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVEDSEALT 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 9840230x42DRAWN BY:REVIEWED BY:IF SHEET MEASURES LESS THAN 30"X42", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLYTHIS DRAWING IS INTENDED FOR INFORMATIONPURPOSES ONLY FOR USE BY THE ARCHITECT ANDENGINEERS TO PREPARE THEIR DOCUMENTS. SEEAPPROVED KITCHEN EQUIPMENT CONTRACTORROUGH-IN DRAWINGS FOR CONSTRUCTION.5/14/2020 3:04:06 PMFS-25.15.202019024KITCHEN ELECTRICALROUGH-INS PLANCONFORMED SETYELM MIDDLE SCHOOL REPLACEMENT402 W ELM AVEYELM, WA 98597YELM COMMUNITY SCHOOLSDH1/4" = 1'-0"1ELECTRICAL PLANELECTRICAL SCHEDULEITEM QTY DESCRIPTION MANUFACTURER MODEL VOLTS PHASE AMPS KW HP ELEC TYPE AFFELECTRICAL COMMENTSITEM05 1 DISHWASHER WITH BOOSTER HEATERHOBART CL44EN-ADV1 208 3 138.9 DIR 24" SINGLE POINT (COMMON) CONNECTION. WIRE TO LIMIT SWITCH MOUNTED TO ITEM 07 (CLEAN DISHTABLE) (BY ELEC. DIV.) 0515 1 HOT WATER DISPENSER BUNN 43600.0002 208 1 19.5 REC 48"1517 1 ELECTRIC CAN OPENER EDLUND 266 120 1 1.5 REC 48"1720 1 MIXER (20 QT.) (FUTURE) HOBART HL200-1STD 120 1 8.0 REC 36"2023 1 WALK-IN COOLER / FREEZER ASSEMBLY AMERICAN PANEL CUSTOM 120 1 15.0 800 DIR (2 CONNECTIONS) STUB DOWN, SEE DETAIL "5" SHEET FS-2 FOR WIRING DIAGRAM2324 1 UNIT COOLER (COOLER) OMNI OTM-07-DS-A-1-6 120 1 1.0 JBOX STUB DOWN. SEE DETAIL "5" SHEET FS-2 FOR WIRING DIAGRAM2425 1 UNIT COOLER (FREEZER) OMNI OTF-07-DS-E-2-6 208 1 8.2 JBOX STUB DOWN. 5 COLOR CODED WIRES TO REFRIGERATION RACK ITEM 28, SEE DETAIL "5" SHEET FS-2 FOR WIRING DIAGRAM 2528 1 REMOTE REFRIGERATION RACK (VERIFY LOCATION) OMNITEMP OTA1-AC-H-2-0-3-4 208 3 18.1 DIR STUB UP, VERIFY LOCATION2829 1 AIR CURTAIN (UNHEATED) MARS STD242-1UA-PW 120 1 5.1 JBOX 120" INTER-CONNECT WITH DOOR ACTIVATED MICROSWITCH (BY ELECTRICAL DIVISION)2931 1 EXHAUST HOOD W/ MAKE-UP AIR (TYPE-1) GAYLORD ELX-GBD-A-DCA-56 1DIR (2 @ 120V AT 15.0 AMPS EA.) STUB DOWN, LIGHT AND FAN SWITCH BY ELEC. DIV; AUTOSTART/ STOP FAN INTERLOCK. SEE FSV-2 FOR ADDITIONAL INFORMATION AND DETAILS. 3133 1 FIRE SUPRESSION SYSTEM ANSUL R-102 WET 120 1 2.0 DIR STUB DOWN, CONDUIT RUN ABOVE CEILING3336 2 MOBILE CONVECTION OVEN (DOUBLE STACKED) LANG MANUFACTURINGGCOF-AP2120 1 7.1REC(2) CONNECTIONS @ +18" AND +36"3638 1 CONVECTION STEAMER W/ MOBILE STANDACCU TEMP PRODUCTSN61201D120 1 1.0REC 36"3841 1 MICROWAVE OVENPANASONICNE-1054120 1 13.4 1000REC 66"4143 2 MOBILE HOT HOLDING CABINETCRES CORH-137-UA-12D120 1 12.0RECOUTLET LOCATED ON ITEM 44 (ISLAND WORKTABLE)4344 2 ISLAND WORKTABLECUSTOM FABRICATEDSTUB UP, CONNECT TO OUTLET FOR ITEM 43 (MOBILE HOT HOLDING CABINET) (BY ELECT. DIV.)4449 2 HOT FOOD WELLS (DROP-IN)WELLSMOD-300TDM208 33720JBOXSTUB UP, CONNECT TO FIXTURE MOUNTED JBOX, INTER-CONNECT THRU CONTROLS (BY ELECTRICAL DIVISION)4951 1 SERVERY COUNTERCUSTOM FABRICATEDSTUB UP, CONNECT TO OUTLETS FOR ITEM 49 (HOT FOOD WELLS), ITEM 52 (HEATED DISPLAY CASE) & ITEM 53 (REFROGERATION RACK) (BY ELECTRICAL DIVISION)5152 2 HEATED DISPLAY CASE (COUNTERTOP)HATCOGR2SDS-42D 120/208 1 12.4RECOUTLET LOCATED ON ITEM 51 (SERVERY COUNTER)5253 2 REFRIGERATED COLD PAN (DROP-IN)DELFIELDN8156BP120 1 3.1REC 18" OUTLET LOCATED ON ITEM 51 (SERVERY COUNTER)5355 2 MOBILE MILK COOLERTRUE FOOD SERVICE EQUIPMENT, INC. TMC-49-DS-SS-HC 120 1 2.71/3 REC 18"5557 2 MOBILE CASHIER STATIONPIPER PRODUCTS2-CD120 1RECSTUB UP, 15AMP CIRCUIT. CONNECTS TO FLOOR OUTLET PROVIDED BY E.C. REQUIRES A DATA LINK PROVIDED BY E.C.57