E-101_ ELECTRICAL SITE PLAN Rev.2 markup (1)
TTTWWTTVANVAN 8??GRAVELEDWARDS STREET NWCOATES ROAD SESOLBERG STREET NWEDWARDS STREET NWEDWARDS STREET NWEDWARDS STREET NWCOATES ROAD SESOLBERG STREET NWSOLBERG STREET NWSOLBERG STREET NW AVE NWVE NWAPPROX DRAIN FIELDLATERAL PER RECORDSAPPROX DRAIN FIELDLATERAL PER RECORDSAPPROX DRAIN FIELDLATERAL PER RECORDSAPPROX DRAIN LINESPER RECORDSAPPROX DRAIN LINESPER RECORDSAPPROX DRAIN LINESPER RECORDSTTWWTHHREADERBOARDAL3AL3AL3ELECTRICALROOM LOCATIONMECHANICALROOM LOCATIONHHEXSITING READER BOARDCONSTRUCTION NOTESCOORDINATE EXACT LIGHT FIXTURE DISTANCE FROM MONUMENT SIGNWITH MANUFACTURER PRIOR TO ROUGH-IN.PROVIDE CONNECTION TO TRASH COMPACTOR. COORDINATE ALL WORKWITH MANUFACTURER PRIOR TO ROUGH-IN. (480V, 3Ø, 4W, 30A MOP). 1"C.W/(4)#10 CU. & (1) #10 CU GND.PROVIDE (2) 4" CONDUIT FOR FUTURE FIELD LIGHTING SYSTEM.PROVIDE HANDHOLE FOR FUTURE SCOREBOARD.PROVIDE HANDHOLE FOR FUTURE FIELD LIGHTING DISTRIBUTION BOARD.BASE BID - PROVIDE (1) 1" CONDUIT FOR FUTURE SCOREBOARDALT BID #1 - PROVIDE POWER TO SCOREBOARD. (120V, 1Ø, 20A). (1) 1"C.W/(2)#10 CU. & (1) #10 CU GND.PROVIDE (2) 4" UNDERGROUND CONDUIT FOR FUTURE.PROVIDE HANDHOLE FOR FUTURE USE.PROVIDE FOG-TITE TYPE 2 WITH GALVANIZED LID OR EQUAL.PROVIDE CONNECTION TO EXISTING READER BOARD. (1) 1"C. W/(2)#3 CU. &(1)#3 CU GND.READER BOARD LOCATION. COORDINATE EXACT LOCATION WITH CIVILPRIOR TO ROUGH-IN.PROVIDE CONNECTION TO GENERATOR BLOCK HEATER. COORDINATEEXACT REQUIREMENT WITH GENERATOR PROVIDER. (120V, 1Ø, 30A).COORDINATE ALL WORK WITH GENERATOR MANUFACTURE. 1"C. W/(2)#8 CU.& (1)#10 CU GND.PROVIDE CONNECTION TO GENERATOR BATTERY CHARGER. COORDINATEEXACT REQUIREMENT WITH GENERATOR PROVIDER. (120V, 1Ø).COORDINATE ALL WORK WITH GENERATOR MANUFACTURE. 1"C. W/(2)#10CU. & (1) #10 CU GND.PROVIDE FUSED DISCONNECT MANUAL TRANSFER SWITCH FOREMERGENCY GENERATOR TEMP POWER SOURCE. SEE ONE-LINE DIAGRAMON SHEET E601 FOR ADDITIONAL INFORMATION.PROVIDE WEATHER PROOF RECEPTACLE FOR TEMP POWER SOURCECONNECTION.PROVIDE (1) 4" CONDUIT FOR IRRIGATION SYSTEM IN CUST OFFICE 195A.COORDINATE EXACT LOCATION WITH LANDSCAPE CONTRACTOR PRIOR TOROUGH-IN.PROVIDE CONNECTION TO READER BOARD. (1) 1"C. W/(2)#6 CU. & (1)#6 CUGND.COORDINATE EXACT FLAG POLE LIGHT AND SOLAR POWER PACKMOUNTING WITH FLAG POLE MANUFACTURE. COORDINATE EXACT FLAGPOLE LOCATION WITH CIVIL AND ARCHITECT.SEE ONE-LINE DIAGRAM FOR ADDITIONAL INFORMATION.EXISTING PSE UTILITY POLE.ELECTRICAL CONTRACTOR TO COORDINATE WITH PSE FOR REMOVAL OFOVERHEAD UTILITY LINES AT TIME OF DEMOLITION OF EXISTING BUILDING.PROVIDE CONNECTION TO HOT BOX. COORDINATE EXACT POWERREQUIREMENT WITH CIVIL AND CITY OF YELM PRIOR TO ROUGH-IN.PROVIDE DISCONNECT PER 427.55 (A) NEC 2017 (DISCONNECT SHALL BEINDICATED TYPE AND CAPABLE OF BEING LOCKED IN OPEN (OFF)POSITION.)SEE ONE-LINE DIAGRAM E-601 FOR EXACT UNDERGROUND CONDUITS INTOTHE BUILDING FROM EMERGENCY GENERATOR.230KW EMERGENCY GENERATOR. SEE ONE-LINE DIAGRAM ON SHEET E-601FOR ADDITIONAL INFORMATION.PSE UTILITY SERVICE TRANSFORMER. COORDINATE EXACT LOCATION WITHPSE.PROVIDE (1) 1" CONDUIT BETWEEN PIV AND FIRE ALARM PANEL LOCATION.COORDINATE EXACT LOCATION WITH CIVIL PRIOR TO ROUGH-IN.PROVIDE GUY WIRE AS REQUIRED. COORDINATE ALL WORK WITH PSE.PROVIDE RECEPTACLE FOR CONTAINER CHARGING TOOLS. COORDINATEEXACT LOCATION WITH ARCHITECT AND THE SCHOOL DISTRICT PRIOR TOROUGH-IN. PROVIDE MOUNTING HARDWARE AS REQUIRED.EXISTING EXTERIOR BUILDING MOUNTED RECEPTACLE. SEE SHEET E321.4FOR RECEPTACLE INFORMATIONEXTEND EXISTING CIRCUIT TO (1) NEW GFCI RECEPTACLE INWEATHERPROOF ENCLOSURE AS INDICATED.11ML1ML11" = 40'-0"1ELECTRICAL SITE PLANTRUENORTHPLANNORTH 223P-30AWAL1AL1AL2AL1AL3AL3AL3AL1AL1AL2AL2AL1AL1AL1AL1AL1AL1AL2AL2AL2AL2AL2r1r1r1r1r1r1r1r1r1r2r2r2r2r2r2r2r4r4r4r4r4r4r3r3r3r3r3TEXISTING PRIMARY PSE POLEEXISTING PRIMARY PSE POLEEXISTING PRIMARY PSE POLEJJ319GENERAL NOTES1. COORDINATE ALL ROUTING OF UNDERGROUND CONDUITS WITH OTHEREXISTING AND NEW UTILITIES. COORDINATE LOCATIONS WITHARCHITECTURAL, CIVIL, MECHANICAL AND LANDSCAPE PLANS.2. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ANY ADDITIONALHANDHOLES TO MEET THE UTILITIES BEND QUANTITY REQUIREMENT.DEPENDING ON THE ACTUAL CONDUIT ROUTING, CONTRACTOR MAY ADDADDITIONAL HANDHOLES.3. SEE SHEET E-501 FOR TRENCHING AND CONCRETE POLE BASE DETAILS.4. CONDUIT AND PIPE ROUTING SHOWN IS DIAGRAMMATIC. CONTRACTORSHALL FIELD VERIFY ALL CONDUIT AND PIPE PRIOR TO ROUGH-IN.5. ELECTRICAL CONTRACTOR TO COORDINATE AND COMPLY WITH PSE,AND NEC REQUIREMENTS.6. SEE ONE-LINE DIAGRAMS FOR CONDUIT/CONDUCTORS INFORMATION.7. COORDINATE PRIMARY POWER WORK WITH PSE POWER.8. PROVIDE MINIMUM OF 1" C. W / (2)#10 CU. & (1)#10 CU GND. FOR ALLEXTERIOR LIGHTING CIRCUITS.9. PROVIDE PULL STRINGS IN ALL SPARE OR EMPTY CONDUITS.10. SEE EXTERIOR LIGHTING CONTROL RELAY SCHEDULE 'LCR' ON SHEETE-514 FOR SITE LIGHTING CIRCUITING INFORMATION.11. HANDHOLES SHALL BE FOG-TITE TYPE 2 OR EQUAL.HHHHHHHHHHHHTELECOMMUNICATIONS CONSTRUCTION NOTESPROVIDE HANDHOLE FOR FUTURE SCOREBOARD.ALT BID #1 - PROVIDE OM3 MULTI-MODE FIBER FOR SCORE BOARD.PROVIDE TERMINATIONS AS REQUIRED.PROVIDE HANDHOLE FOR FIELD LIGHTING.PROVIDE (1) 4" CONDUIT FOR FUTURE.PROVIDE HANDHOLE FOR FUTURE USE.PROVIDE (1) 2" CONDUIT TO IDF ROOM.PROVIDE (1) 2" CONDUIT TO MAIN SERVER ROOM.T1T244T1IDF ROOM LOCATION55T266377T3T3T4T488MAIN SERVER ROOM910HH1111T5917T5HH11910T6T5WW12131213 14151415G,W1616L2-6L2-6L2-6L2-6L2-6L2-6L2-6L2-6L2-6L2-8L2-8L2-8L2-8L2-8L2-8L2-8L2-10L2-10L2-10L2-10L2-10L2-10L2-10L2-10L2-10L2-10L2-10P1A-41MH-43,45,47P1A-47, #10 CU.GP1-76GP1-74P1A-51P1A-53171818FL11919CCT7T7PROVIDE MULIT-MODE FIBER FOR READERBOARD.PROVIDE MULTI-MODE FIBER FOR CCTV CAMERA AND WAP CONNECTIONPROVIDE POE SWITCH FROM AVIGILON MODEL ES-PS-S4 FOR CONNECTIONTO CCTV CAMERA AND WAP. LOCATE IN POLE-MOUNTED WEATHER-PROOFENCLOSURE. PROVIDE POWER CONDUCTORS FROM THE CCTV POWERSUPPLY.PROVIDE (1) 4" CONDUIT FOR TELEPHONE SERVICE CABLING.PROVIDE (1) 4" CONDUIT FOR FIBER SERVICE CABLING.PROVIDE HANDHOLE FOR FIBER SERVICE CABLING.T7T5T6T6HHT5T8T8T-01T-02HH99HH9T6T8WAPT9T9WAPHHHHEXISTING COMM POLEHHT10T11T11T11T10T10202020202121212222 P1A-55#10 CU.CT-03232324242525W26261E-501(TYPICAL)1E-501(TYPICAL)2727G,WP1F-62282829293030HHT12T12(3) SEPTIC PUMPCONTROL PANELS3131PROVIDE (1)3/4" C. W/(2)#8 CU. & (1)#8 CU GND. TO EACH SEPTICPUMPS. DEPLEX PUMPS ON EACH TANKS. COORDINATE EXACTPUMP LOCATIONS WITH CIVIL AND PROVIDER. PROVIDE (1) 3/4"CONDUIT TO EACH TANKS FOR FLOAT / LEVEL CONTROL WIRING.PROVIDE CONTROL WIRES PER MANUFACTURER'SRECOMMENDATION. PROVIDE ANY ELECTRICAL DEVICES ANDEQUIPMENT PER CIVIL DETAIL DRAWINGS ON SHEET C-506 ANDC-507. ALL CONDUIT SHALL BE SEAL-OFFS. COORDINATE ALLWORK WITH CIVIL AND MANUFACTURER.PROVIDE CONNECTION TO CCTV ENCLOSURE ON LIGHT POLE.PROVIDE (1) 3/4"C. W/(2) #10 CU. & (1) #10 CU. GND.PROVIDE (1) 3/4"C. W/(2) #8 CU. & (1) #8 CU. GND.3131PUMP#1 & PUMP#2PUMP#3 & PUMP#4PUMP#5 & PUMP#6JRFI-250.13232GSP-2RFI-250.1J32P1A-43333433346/26/2019 11:51:50 AM YELM MIDDLE SCHOOL REPLACEMENT 402 W YELM AVE YELM, WA 98597 YELM COMMUNITY SCHOOLSSHEETPROJECTBCRA NO.DATEREVISIONSSHEET TITLESEALT 253.627.4367 F 253.627.4395 WWW.BCRADESIGN.COM 2106 PACIFIC AVENUE, SUITE 300, TACOMA, WA 98402CONFORMED SET30x42 DRAWN BY:REVIEWED BY:IF SHEET MEASURES LESS THAN 30"X42", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY5.15.202019024© COPYRIGHT 2019 - BCRA, INC. ALL RIGHTS RESERVEDELECTRICAL SITE PLANE-101RFI-250.1RFI 230RFI 277RFI 283RFI 283