Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2021.0276.BP0020 wsec project_summary_form
5/14/2021 https://waenergycodes.com/print_project_summary_form.php?k=aWQ9Mjk3OSZmdmk9MTcmcmVzZXQ9MQ==&debug=1 https://waenergycodes.com/print_project_summary_form.php?k=aWQ9Mjk3OSZmdmk9MTcmcmVzZXQ9MQ==&debug=1 1/2 Administered by: ©2021 NEEA, All rights reserved Date: May 14, 2021 MECHANICAL COMPLIANCE SUMMARY 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all R1 Project & Applicant Information Project Title 21-055 MCW YELM - 2018 WSEC For Building Department Use: Project Address 1002 RHOTON RD SE YELM, WA 98597 Applicant Name Office HBHU Applicant Phone 253-383-3257 Applicant Email wanrec@hultzbhu.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Manufacturing/Factory Building Cond. Floor Area 20,408 General Project Types New Building New Building or Addition Mechanical Scope Single Zone Systems & Equipment Alteration Mechanical Scope Project Cond. Floor Area 20,408 Floors Above Grade 2 Compliance Method Compliance Method 1 - General Mechanical Project Description Mechanical Compliance Scope and Method Project Type Mechanical Scope Economizer Exception(s) Applied? DOAS Ventilation Provided? Higher Equipment Efficiency Option Applied? Equipment Efficiency Compliance Verification New Building Single Zone Systems & Equipment No Yes NA COMPLIES Additional Efficiency Credits Included (AEC) Does building include occupancy classifications requiring DOAS?Yes Does project include DOAS equipment?Yes Based on project scope do TSPR requirements apply?No Do all systems comply with Appendix D standard reference design or qualify for an exception to TSPR?No Scope & Space Conditioning NEW BUILDING - SINGLE ZONE SYSTEMS & EQUIPMENT Compliance Verification COMPLIES Single Zone Air Systems Category - Fan coil unit, hydronic & VRF Air Systems Summary Information System/Equip ID Quantity of Items Supply Airflow Control Ventilation Standard Ventilation CFM (Total if Multiple Items) Ventilation Air Source Paired with DOAS HP-111 Variable air volume IMC Ventilation Separate DOAS DOAS-2 HP-10 Variable air volume IMC Ventilation Separate DOAS DOAS-1 HP-11 Variable air volume IMC Ventilation Separate DOAS DOAS-1 HP-104 Variable air volume IMC Ventilation Other System Air Systems & Equipment - Cooling System/ Equip ID Cooling System/Equip Type Specific Type Cooling Capacity per item (Btu/h) AEC Efficiency Multiplier Econo Exception Multiplier (FL & PL) Combined Efficiency Multiplier (AEC & Econo) Proposed Cooling Efficiency CE Units Proposed Part Load Efficiency PL Units Efficiency Compliance Verification HP-10 Fan coils, hydronic & VRF, cooling VRF 12,000 1 0 COMPLIES HP-11 Fan coils, hydronic & VRF, cooling VRF 12,000 1 0 COMPLIES HP-104 Fan coils, hydronic & VRF, cooling VRF 4,000 1 0 COMPLIES HP-111 Fan coils, hydronic & VRF, cooling VRF 9,000 1 0 COMPLIES Air Systems & Equipment - Heating System /Equip ID Heating System/Equip Type Specific Type Heat Pump Heating Capacity (Btu/h)Cooling Capacity (Btu/h)AEC Efficiency Multiplier Proposed Heat Pump Heating Efficiency HPH Units Proposed Low OSA Temp Efficiency LTH Units Efficiency Compliance Verification HP-10 Fan coils, hydronic & VRF, heating VRF 1 COMPLIES HP-104 Fan coils, hydronic & VRF, heating VRF 1 COMPLIES 5/14/2021 https://waenergycodes.com/print_project_summary_form.php?k=aWQ9Mjk3OSZmdmk9MTcmcmVzZXQ9MQ==&debug=1 https://waenergycodes.com/print_project_summary_form.php?k=aWQ9Mjk3OSZmdmk9MTcmcmVzZXQ9MQ==&debug=1 2/2 HP-11 Fan coils, hydronic & VRF, heating VRF 1 COMPLIES HP-111 Fan coils, hydronic & VRF, heating VRF 1 COMPLIES Air Systems & Equipment Details System/Equip ID Area(s) Served Location In Project Documents - Plan/Detail # HP-111 OFFICE 111 M4.1 System/Equip ID for a single or multiple items?: Single item Cooling Capacity Source: HP-2 Heating Capacity Source: HP-2 HP-10 OFFICE M-10 M4.1 System/Equip ID for a single or multiple items?: Single item Cooling Capacity Source: HP-1 Heating Capacity Source: HP-1 HP-11 OFFICE M-11 M4.1 System/Equip ID for a single or multiple items?: Single item Cooling Capacity Source: HP-1 Heating Capacity Source: HP-1 HP-104 BREAK RM 104 M4.1 System/Equip ID for a single or multiple items?: Single item Cooling Capacity Source: HP-1 Heating Capacity Source: HP-1 Single Zone Air Systems Category - Unit heaters & duct heaters Air Systems Summary Information System/Equip ID Quantity of Items Ventilation Standard Ventilation CFM (Total if Multiple Items) Ventilation Air Source Paired with DOAS UH-102 IMC Ventilation Other System UH-101 IMC Ventilation Other System UH-103 IMC Ventilation Other System Air Systems & Equipment - Heating System /Equip ID Heating System/Equip Type Specific Type Heating Capacity HC Units Proposed Heating Efficiency HE Units Efficiency Compliance Verification UH-101 Unit heater Warm air, gas fired 45,000 Btu/h 80.0 Ec COMPLIES UH-102 Unit heater Warm air, gas fired 60,000 Btu/h 80.0 Ec COMPLIES UH-103 Unit heater Warm air, gas fired 30,000 Btu/h 80.0 Ec COMPLIES Air Systems & Equipment Details System/Equip ID Area(s) Served Location In Project Documents - Plan/Detail # UH-102 WORKSHOP 102 M4.1 System/Equip ID for a single or multiple items?: Multiple items w/ identical heating & cooling capacity WSEC Equip Efficiency Reference Table - Heating: Table C403.3.2(4) Warm Air Furnaces UH-101 WORKSHOP 101 M4.1 System/Equip ID for a single or multiple items?: Multiple items w/ identical heating & cooling capacity WSEC Equip Efficiency Reference Table - Heating: Table C403.3.2(4) Warm Air Furnaces UH-103 WORKSHOP 103 M4.1 System/Equip ID for a single or multiple items?: Multiple items w/ identical heating & cooling capacity WSEC Equip Efficiency Reference Table - Heating: Table C403.3.2(4) Warm Air Furnaces