Loading...
2021.0290.MP0070 Rosemont Retirement Submittals SUBMITTAL Project Rosemont Retirement Date Tuesday, April 13, 2021 Contractor Sunset Air 5t Unit Project: Rosemont Retirement 04/13/2021 Prepared By: 07:32AM Packaged Rooftop Builder 1.58 Page 2 of 21 5t Unit Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Spec Sheet Unit Report For 5t Unit Project: Rosemont Retirement 04/13/2021 Prepared By: 07:32AM Packaged Rooftop Builder 1.58 Page 3 of 21 Unit Parameters Unit Model: ....................... 48GCEM06A2A5-0A0A0 Unit Size: ................................................06 (5 Tons) Volts-Phase-Hertz: ..................................... 208-3-60 Heating Type: ..................................................... Gas Duct Cfg: ............ Vertical Supply / Vertical Return Medium Heat Two Stage Cooling Models Dimensions (ft. in.) & Weight (lb.) *** Unit Length: ......................................... 6' 2.375'' Unit Width:......................................... 3' 10.625'' Unit Height: ......................................... 3' 5.375'' *** Total Operating Weight: ...................... 618 lb *** Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. Lines and Filters Gas Line Size: ..................................................... 1/2 Condensate Drain Line Size: .............................. 3/4 Return Air Filter Type: ........................... Throwaway Return Air Filter Quantity: ....................................... 4 Return Air Filter Size: ..............................16 x 16 x 2 Unit Configuration Direct Drive - EcoBlue - Medium Static Al/Cu - Al/Cu Base controls set up for field installed air management devices Standard Packaging Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger - Aluminized(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48GCEM06A2A5-0A0A0 Rooftop Unit 2 Base Unit Direct Drive - EcoBlue - Medium Static Electromechanical control, No intake or exhaust option. Accessories CRECOMZR067A01 Ultra LOW LEAK - Vertical EconoMi$er X with solid-state W7220 controller 2 --HH--57AC-081 Enthalpy Control for W7220 Controller 2 Certified Drawing for 5t Unit Project: Rosemont Retirement 04/13/2021 Prepared By: 07:32AM Packaged Rooftop Builder 1.58 Page 4 of 21 Certified Drawing for 5t Unit Project: Rosemont Retirement 04/13/2021 Prepared By: 07:32AM Packaged Rooftop Builder 1.58 Page 5 of 21 Certified Drawing for 5t Unit Project: Rosemont Retirement 04/13/2021 Prepared By: 07:32AM Packaged Rooftop Builder 1.58 Page 6 of 21 Performance Summary For 5t Unit Project: Rosemont Retirement 04/13/2021 Prepared By: 07:32AM Packaged Rooftop Builder 1.58 Page 7 of 21 Part Number:48GCEM06A2A5-0A0A0 ARI SEER: ................................................................................................................................................... 16.10 Base Unit Dimensions Unit Length: ............................................................................................................................................. 74.4 in Unit Width: .............................................................................................................................................. 46.6 in Unit Height: ............................................................................................................................................. 41.4 in Operating Weight Base Unit Weight: .................................................................................................................................... 555 lb Medium Heat: ............................................................................................................................................. 63 lb Total Operating Weight: ........................................................................................................................... 618 lb Unit Unit Voltage-Phase-Hertz: ............................................................................................................... 208-3-60 Air Discharge:.................................................................................................................................... Vertical Fan Drive Type:.................................................................................................................................... Direct Actual Airflow: ........................................................................................................................................ 2000 CFM Site Altitude: ................................................................................................................................................. 0 ft Cooling Performance Condenser Entering Air DB: .................................................................................................................... 95.0 F Evaporator Entering Air DB: .................................................................................................................... 80.0 F Evaporator Entering Air WB: ................................................................................................................... 67.0 F Entering Air Enthalpy: ........................................................................................................................... 31.44 BTU/lb Evaporator Leaving Air DB: ..................................................................................................................... 57.6 F Evaporator Leaving Air WB: .................................................................................................................... 57.1 F Evaporator Leaving Air Enthalpy: .......................................................................................................... 24.44 BTU/lb Gross Cooling Capacity: ....................................................................................................................... 63.00 MBH Gross Sensible Capacity: ...................................................................................................................... 48.32 MBH Compressor Power Input: ....................................................................................................................... 4.11 kW Coil Bypass Factor: ............................................................................................................................... 0.047 Heating Performance Heating Airflow: ...................................................................................................................................... 2000 CFM Entering Air Temp: .................................................................................................................................. 70.0 F Leaving Air Temp: ................................................................................................................................. 110.7 F Gas Heating Input Capacity: ....................................................................................................... 82.0 / 110.0 MBH Gas Heating Output Capacity: ...................................................................................................... 65.0 / 88.0 MBH Temperature Rise: .................................................................................................................................. 40.7 F Thermal Efficiency (%): ........................................................................................................................... 80.0 Supply Fan External Static Pressure: ......................................................................................................................... 0.50 in wg Options / Accessories Static Pressure Economizer: ...................................................................................................................................... 0.12 in wg Total Application Static (ESP + Unit Opts/Acc.): ..................................................................................... 0.62 in wg Fan RPM: ............................................................................................................................................... 2024 Fan Power: .............................................................................................................................................. 0.88 BHP NOTE: ............................................................................................ Selected IFM RPM Range: 1387 - 2390 Electrical Data Voltage Range: ............................................................................................................................... 187 - 253 Compressor #1 RLA: ............................................................................................................................... 16.2 Compressor #1 LRA: ................................................................................................................................ 110 Indoor Fan Motor Type: .......................................................................................................................... MED Indoor Fan Motor FLA: .............................................................................................................................. 8.6 Combustion Fan Motor FLA (ea): ............................................................................................................ 0.48 Power Supply MCA: ................................................................................................................................... 31 Performance Summary For 5t Unit Project: Rosemont Retirement 04/13/2021 Prepared By: 07:32AM Packaged Rooftop Builder 1.58 Page 8 of 21 Power Supply MOCP (Fuse or HACR): ...................................................................................................... 45 Disconnect Size FLA: ................................................................................................................................. 30 Disconnect Size LRA: .............................................................................................................................. 126 Electrical Convenience Outlet: .............................................................................................................. None Outdoor Fan [Qty / FLA (ea)]: .............................................................................................................. 1 / 1.5 Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 91.6 89.0 85.6 125 Hz 82.7 78.7 84.7 250 Hz 76.7 71.5 80.5 500 Hz 73.4 65.4 76.0 1000 Hz 70.0 67.7 72.4 2000 Hz 67.4 58.9 68.0 4000 Hz 63.7 52.2 62.8 8000 Hz 59.9 46.5 59.3 A-Weighted 76.6 71.6 79.0 Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground: .................................. 30.0 ft 2. Horizontal distance from unit to receiver: ........... 50.0 ft 3. Receiver height above ground: ............................ 5.7 ft 4. Height of obstruction: ........................................... 0.0 ft 5. Horizontal distance from obstruction to receiver: . 0.0 ft 6. Horizontal distance from unit to obstruction: ........ 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 85.6 84.7 80.5 76.0 72.4 68.0 62.8 59.3 89.2 Lw B 59.4 68.6 71.9 72.8 72.4 69.2 63.8 58.2 78.5 LwA C 53.2 52.3 48.1 43.6 40.0 35.6 30.4 26.9 56.8 Lp D 27.0 36.2 39.5 40.4 40.0 36.8 31.4 25.8 46.1 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A-Weighted Sound Power Levels at Unit's Acoustic Center, LwA Performance Summary For 5t Unit Project: Rosemont Retirement 04/13/2021 Prepared By: 07:32AM Packaged Rooftop Builder 1.58 Page 9 of 21 C Sound Pressure Levels at Specific Distance from Unit, Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. 900 RPM 1100 RPM 1300 RPM 1500 RPM 1700 RPM 1900 RPM 2100 RPM 2300 RPM 2500 RPM 2700 RPM 2900 RPM 0.50 BHP 0.75 BHP 1.00 BHP 1.50 BHP 2.00 BHP 3.00 BHP SC RP Fan Curve SC - System Curve RP - Rated Point RPM = 2024 BHP = 0.88 Maximum RPM = 2836 Maximum BHP = 5.00Static Pressure (in. wg.)Airflow (CFM - thousands) 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 Unit Feature Sheet for 5t Unit Project: Rosemont Retirement 04/13/2021 Prepared By: 07:32AM Packaged Rooftop Builder 1.58 Page 10 of 21 7.5t Unit Project: Rosemont Retirement 04/13/2021 Prepared By: 07:32AM Packaged Rooftop Builder 1.58 Page 12 of 21 7.5t Unit Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Spec Sheet Unit Report For 7.5t Unit Project: Rosemont Retirement 04/13/2021 Prepared By: 07:32AM Packaged Rooftop Builder 1.58 Page 13 of 21 Unit Parameters Unit Model: ........................ 48TCED08A2A5-0A0G0 Unit Size: ............................................. 08 (7.5 Tons) Volts-Phase-Hertz: ..................................... 208-3-60 Heating Type: ..................................................... Gas Duct Cfg: ............ Vertical Supply / Vertical Return Medium Heat Round Tube Plate Fin Coils Dimensions (ft. in.) & Weight (lb.) *** Unit Length: ......................................... 7' 4.125'' Unit Width:............................................. 4' 11.5'' Unit Height: ........................................... 3' 5.25'' *** Total Operating Weight: ...................... 960 lb *** Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. Lines and Filters Gas Line Size: ..................................................... 3/4 Condensate Drain Line Size: .............................. 3/4 Return Air Filter Type: ........................... Throwaway Return Air Filter Quantity: ....................................... 4 Return Air Filter Size: ..............................16 x 20 x 2 Unit Configuration Medium Static Option (Belt Drive) Al/Cu - Al/Cu Base Electromechanical Controls Standard Packaging 2-Speed indoor fan motor controlled by VFD Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger - Aluminized(std.) 15-Year heat exchanger - Stainless Steel(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48TCED08A2A5-0A0G0 Rooftop Unit 1 Base Unit Medium Static Option (Belt Drive) Electromechanical control, No intake or exhaust option. 2 Speed Fan Controller (VFD) Accessories CRECOMZR069A01 Ultra LOW LEAK - Vertical EconoMi$er 1 Certified Drawing for 7.5t Unit Project: Rosemont Retirement 04/13/2021 Prepared By: 07:32AM Packaged Rooftop Builder 1.58 Page 14 of 21 Certified Drawing for 7.5t Unit Project: Rosemont Retirement 04/13/2021 Prepared By: 07:32AM Packaged Rooftop Builder 1.58 Page 15 of 21 Certified Drawing for 7.5t Unit Project: Rosemont Retirement 04/13/2021 Prepared By: 07:32AM Packaged Rooftop Builder 1.58 Page 16 of 21 Performance Summary For 7.5t Unit Project: Rosemont Retirement 04/13/2021 Prepared By: 07:32AM Packaged Rooftop Builder 1.58 Page 17 of 21 Part Number:48TCED08A2A5-0A0G0 ARI EER: ..................................................................................................................................................... 11.00 IEER: ............................................................................................................................................................. 12.8 Base Unit Dimensions Unit Length: ............................................................................................................................................. 88.1 in Unit Width: .............................................................................................................................................. 59.5 in Unit Height: ............................................................................................................................................. 41.3 in Operating Weight Base Unit Weight: .................................................................................................................................... 835 lb Medium Heat: ............................................................................................................................................. 15 lb Medium Static Option (Belt Drive): ............................................................................................................. 15 lb 2 Speed Fan Controller (VFD): ................................................................................................................ 20 lb Accessories Ultra LOW LEAK - Vertical EconoMi$er: ................................................................................................. 75 lb Total Operating Weight: ........................................................................................................................... 960 lb Unit Unit Voltage-Phase-Hertz: ............................................................................................................... 208-3-60 Air Discharge:.................................................................................................................................... Vertical Fan Drive Type:....................................................................................................................................... Belt Actual Airflow: ........................................................................................................................................ 3000 CFM Site Altitude: ................................................................................................................................................. 0 ft Cooling Performance Condenser Entering Air DB: .................................................................................................................... 95.0 F Evaporator Entering Air DB: .................................................................................................................... 80.0 F Evaporator Entering Air WB: ................................................................................................................... 67.0 F Entering Air Enthalpy: ........................................................................................................................... 31.44 BTU/lb Evaporator Leaving Air DB: ..................................................................................................................... 58.7 F Evaporator Leaving Air WB: .................................................................................................................... 57.6 F Evaporator Leaving Air Enthalpy: .......................................................................................................... 24.76 BTU/lb Gross Cooling Capacity: ....................................................................................................................... 90.10 MBH Gross Sensible Capacity: ...................................................................................................................... 68.90 MBH Compressor Power Input: ....................................................................................................................... 6.40 kW Coil Bypass Factor: ............................................................................................................................... 0.092 Heating Performance Heating Airflow: ...................................................................................................................................... 3000 CFM Entering Air Temp: .................................................................................................................................. 70.0 F Leaving Air Temp: ................................................................................................................................. 115.7 F Gas Heating Input Capacity: ..................................................................................................... 120.0 / 180.0 MBH Gas Heating Output Capacity: .................................................................................................... 98.0 / 148.0 MBH Temperature Rise: .................................................................................................................................. 45.7 F Thermal Efficiency (%): ........................................................................................................................... 82.0 Supply Fan External Static Pressure: ......................................................................................................................... 0.50 in wg Options / Accessories Static Pressure Economizer: ...................................................................................................................................... 0.11 in wg Total Application Static (ESP + Unit Opts/Acc.): ..................................................................................... 0.61 in wg Fan RPM: ................................................................................................................................................. 763 Fan Power: .............................................................................................................................................. 1.65 BHP NOTE: ................................................................................................ Selected IFM RPM Range: 733 - 949 Electrical Data Voltage Range: ............................................................................................................................... 187 - 253 Compressor #1 RLA: ............................................................................................................................... 13.6 Performance Summary For 7.5t Unit Project: Rosemont Retirement 04/13/2021 Prepared By: 07:32AM Packaged Rooftop Builder 1.58 Page 18 of 21 Compressor #1 LRA: .................................................................................................................................. 83 Compressor #2 RLA: ............................................................................................................................... 13.6 Compressor #2 LRA: .................................................................................................................................. 83 Indoor Fan Motor Type: .......................................................................................................................... MED Indoor Fan Motor FLA: .............................................................................................................................. 8.4 Combustion Fan Motor FLA (ea): ............................................................................................................ 0.48 Power Supply MCA: ................................................................................................................................... 43 Power Supply MOCP (Fuse or HACR): ...................................................................................................... 50 Disconnect Size FLA: ................................................................................................................................. 45 Disconnect Size LRA: .............................................................................................................................. 227 Electrical Convenience Outlet: .............................................................................................................. None Outdoor Fan [Qty / FLA (ea)]: .............................................................................................................. 2 / 1.5 Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 98.2 95.2 85.8 125 Hz 91.4 86.1 84.3 250 Hz 78.0 73.0 80.5 500 Hz 70.8 66.3 78.7 1000 Hz 67.2 63.4 76.4 2000 Hz 65.7 58.5 72.7 4000 Hz 67.1 57.8 68.3 8000 Hz 69.4 57.5 65.1 A-Weighted 79.4 74.3 82.0 Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground: .................................. 30.0 ft 2. Horizontal distance from unit to receiver: ........... 50.0 ft 3. Receiver height above ground: ............................ 5.7 ft 4. Height of obstruction: ........................................... 0.0 ft 5. Horizontal distance from obstruction to receiver: . 0.0 ft 6. Horizontal distance from unit to obstruction: ........ 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 85.8 84.3 80.5 78.7 76.4 72.7 68.3 65.1 89.6 Lw B 59.6 68.2 71.9 75.5 76.4 73.9 69.3 64.0 81.4 LwA Performance Summary For 7.5t Unit Project: Rosemont Retirement 04/13/2021 Prepared By: 07:32AM Packaged Rooftop Builder 1.58 Page 19 of 21 C 53.4 51.9 48.1 46.3 44.0 40.3 35.9 32.7 57.2 Lp D 27.2 35.8 39.5 43.1 44.0 41.5 36.9 31.6 49.0 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A-Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. 400 RPM 500 RPM 600 RPM 700 RPM 800 RPM 900 RPM 1000 RPM 1100 RPM 1200 RPM 0.50 BHP 0.75 BHP 1.00 BHP 1.50 BHP 2.00 BHP 3.00 BHP 5.00 BHP SC RP Fan Curve SC - System Curve RP - Rated Point Note: Please contact application engineering for selections outside the shaded region. RPM = 763 BHP = 1.65 Maximum RPM = 1400 Maximum BHP = 4.70Static Pressure (in. wg.)Airflow (CFM - thousands) 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 Unit Feature Sheet for 7.5t Unit Project: Rosemont Retirement 04/13/2021 Prepared By: 07:32AM Packaged Rooftop Builder 1.58 Page 20 of 21