Loading...
2021.0325.PR0009 Stor-House Yelm Civil Entitlement Plans 06-04-2021i 0 V) 0 M - O o N .E � U Li CD Of E(D oz J N N Z �o U '(S CD L�j � U PROJECT SPECIFICATIONS: THE WORK ON THIS PROJECT SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THE FOLLOWING: 1) THE MOST CURRENT VERSION OF THE WASHINGTON STATE DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS FOR ROAD, BRIDGE, AND MUNICIPAL CONSTRUCTION 2) THE MOST CURRENT EDITION OF THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES FOR STREETS AND HIGHWAYS (MUTCD) 3) THE MOST CURRENT EDITION OF THE INTERNATIONAL BUILDING CODE (IBC) 4) THE MOST CURRENT EDITION OF THE AUTHORITY HAVING JURISDICTION DEVELOPMENT GUIDELINES AND PUBLIC STANDARDS THE CONTRACTOR SHALL OBTAIN COPIES OF THESE PUBLICATIONS AT THE CONTRACTOR'S OWN EXPENSE. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR, MATERIALS, TOOLS, EQUIPMENT, TRANSPORTATION, SUPPLIES, AND INCIDENTALS REQUIRED TO COMPLETE ALL WORK SHOWN ON THESE DRAWINGS AND TO OBTAIN ACCEPTANCE BY THE AUTHORITY HAVING JURISDICTION AND THE PROJECT OWNER. ANY PROPOSED ALTERATIONS BY THE CONTRACTOR AFFECTING THE REQUIREMENTS AND INFORMATION IN THESE DRAWINGS SHALL BE SUBMITTED TO THE ENGINEER OF RECORD IN WRITING FOR APPROVAL. CONTRACTOR LIABILITY NOTE: THE CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY. THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD J.E. GIBSON CONSULTING HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF J.E. GIBSON CONSULTING. GRADING NOTE: ANY CUT AND FILL QUANTITIES, IF SHOWN ON THESE DRAWINGS, ARE ESTIMATED IN-PLACE VOLUMES AND ARE FOR PLANNING PURPOSES ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY QUANTITIES AND APPLY SHRINK AND/OR SWELL FACTORS. TOPOGRAPHIC NOTE: TOPOGRAPHIC INFORMATION SHOWN ON THESE DRAWINGS WERE PROVIDED BY A THIRD PARTY SURVEYOR. THE CONTRACTOR SHALL VERIFY TOPOGRAPHIC INFORMATION IN THE FIELD PRIOR TO SUBMITTING A BID AND SHALL CONTACT THE ENGINEER OF RECORD IF THERE IS A DISCREPANCY. EROSION CONTROL NOTE: EROSION CONTROL MEASURES ARE NOT LIMITED TO THE TO THE ITEMS ON THESE DRAWINGS. THE CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION AND MAINTENANCE OF ALL EROSION CONTROL MEASURES. NO SILTATION OF EXISTING OR PROPOSED STORMWATER FACILITIES SHALL BE ALLOWED. CARE SHALL BE TAKEN TO PREVENT MIGRATION OF SILTS TO OFF-SITE PROPERTIES. ALL DISTURBED EARTH CAUSED BY CONTRACTOR'S ACTIVITIES SHALL BE RESTORED IN ACCORDANCE WITH THE LANDSCAPING PLANS OR HYDROSEEDED IF NO LANDSCAPING PLANS EXIST. IF DISCHARGING TO WATERS OF THE STATE AND DISTURBING MORE THAN ONE (1) OF LAND, THE CONTRACTOR IS RESPONSIBLE FOR APPLYING AND SECURING COVERAGE UNDER WSDOE'S NPDES GENERAL PERMIT. THE CONTRACTOR IS HEREBY NOTIFIED THAT IT CAN TAKE UP TO SIXTY (60) DAYS TO ACQUIRE COVERAGE. REMOVAL & REPLACEMENT OF UNSUITABLE MATERIALS: WHENEVER EXCAVATING ACTIVITIES ON-SITE EXPOSE PEAT, SOFT CLAY, QUICKSAND, OR OTHER UNSUITABLE FOUNDATION MATERIAL, SUCH MATERIAL SHALL BE REMOVED TO THE DEPTH DIRECTED BY THE GEOTECHNICAL ENGINEER AND BACKFILLED WITH SUITABLE FOUNDATION MATERIAL. UNSUITABLE MATERIAL SHALL BE REMOVED FROM THE SITE AND HAULED TO A CONTRACTOR PROVIDED WASTE SITE. THE CONTRACTOR SHALL FURNISH AND PLACE SUITABLE MATERIAL MEETING THE REQUIREMENTS OF THE STANDARD SPECIFICATIONS AND THE IBC. STORM DRAINAGE NOTE: TO PROTECT STORMWATER FACILITIES FROM SEDIMENTATION, THE CONTRACTOR SHALL CONNECT THE FACILITY(IES) TO THE STORM CONVEYANCE SYSTEM AFTER SITE WORK, ROADS, UTILITIES, PERMANENT EROSION CONTROL MEASURES, AND FINAL LANDSCAPING ARE IN PLACE. DEWATERING: FOUNDATIONS, UTILITY TRENCHES, AND ALL OTHER PARTS OF THE CONSTRUCTION SITE SHALL BE DEWATERED AND KEPT FREE OF STANDING WATER AND SATURATED CONDITIONS AS NECESSARY FOR THE PROPER EXECUTION OF THE WORK. THE CONTRACTOR SHALL FURNISH, INSTALL, OPERATE, AND MAINTAIN ALL DRAINS, SUMPS, PUMPS, AND ALL OTHER EQUIPMENT REQUIRED TO PROPERLY DEWATER THE SITE AS SPECIFIED. DEWATERING SYSTEMS THAT CAUSE A LOSS OF SOIL FINES FROM FOUNDATION AND HARDSCAPE AREAS WILL NOT BE PERMITTED. UTILITIES LOCATE NOTE: THE LOCATION OF EXISTING UTILITIES SHOWN HEREON IS BASED ON INFORMATION OBTAINED FROM THE TOPOGRAPHIC SURVEY. J.E. GIBSON CONSULTING ASSUMES NO RESPONSIBILITY AND/OR LIABILITY OF EXISTING UTILITIES SHOWN OR NOT SHOWN HEREON. CONTRACTOR IS ADVISED TO VERIFY THE EXACT SIZE, DIAMETER, DEPTH, AND LOCATION OF EXISTING UTILITIES PRIOR TO STARTING CONSTRUCTION ACTIVITIES. CONTRACTOR SHALL CALL FOR UNDERGROUND LOCATES AT 1-800-424-5555 PRIOR TO STARTING CONSTRUCTION ACTIVITIES. RECORD DRAWINGS: J.E. GIBSON CONSULTING IS REQUIRED BY THE THE AUTHORITY HAVING JURISDICTION TO PROVIDE RECORD DRAWINGS PRIOR TO ACCEPTANCE. J.E. GIBSON CONSULTING WILL NOT CERTIFY RECORD DRAWINGS UNLESS A REPRESENTATIVE OF THE COMPANY HAS INSPECTED ACTUAL INSTALLATION OF UTILITIES PRIOR TO BACKFILLING. THE CONTRACTOR SHALL MAINTAIN ONE SET OF THE APPROVED DRAWINGS THAT SHALL INCLUDE RED LINE MARKUPS (LEGIBLE) OF ANY ALTERATIONS TO THE DESIGN. THE RED LINE MARKINGS SHALL BE SUBMITTED TO THE ENGINEER OF RECORD UPON PROJECT COMPLETION. WORK IN THE RIGHT-OF-WAY: CONTRACTOR SHALL OBTAIN RIGHT-OF-WAY PERMIT AND SHALL SUBMIT A TRAFFIC CONTROL PLAN TO THE AUTHORITY HAVING JURISDICTION PRIOR TO STARTING CONSTRUCTION ACTIVITIES. ALL WORK WITHIN THE RIGHT-OF-WAY SHALL CONFORM TO THE AUTHORITY HAVING JURISDICTION'S STANDARDS. PROJECT INFORMATION: APPLICANT: PARCEL NUMBER SITE ADDRESS: PARCEL AREA: SANITARY SEWER: WATER: FIRE DISTRICT: FLOODZONE: DATUM NOTE: PATRICK GILROY GILROY FAMILY FIVE LLC 1614 -118TH AVE SE BELLEVUE, WA 98005 OFFICE: 425-999-8250 64303400404, 0405, 0402 10512 CREEK STEET SE YELM, WA 98597 1.52 ACRES CITY OF YELM CITY OF YELM SE THURSTON FIRE AUTHORITY NONE SHOWN ON FEMA MAPS VERTICAL - NAVD 88 BASED ON GPS TIES TO MONUMENTS USING WASHINGTON STATE REFERENCE NETWORK. HORIZONTAL - WASHINGTON STATE PLANE COORDINATES, SOUTH ZONE, NAD 83/2011 BASED ON GPS TIES TO MONUMENTS USING WASHINGTON STATE REFERENCE NETWORK. N 1'57'03" E ON WEST LINE OF SECTION 29. LEGAL DESCRIPTION: PARCEL C OF CITY OF YELM BOUNDARY LINE ADJUSTMENT NO. BLA-988215YL, AS RECORDED JUNE 2, 1998 UNDER AUDITOR'S FILE NOS. 3157737 AND 3157738. SURVEY UTILITY NOTE: UTILITIES SHOWN HEREON ARE FROM MAPPING VISIBLE SURFACE APPURTENANCES, MAPPING UTILITY PAINT MARKS FROM A UTILITY LOCATING SERVICE, AND USING RECORD UTILITY SYSTEM MAPS PROVIDED BY OTHERS. BURIED UTILITIES ARE ONLY SHOWN AS APPROXIMATE AND SHOULD BE VERIFIED BEFORE CONSTRUCTION ABBREVIATIONS: AC ASPHALT CONCRETE BCP BEGIN CURB RETURN BM BENCHMARK BVC BEGIN VERTICAL CURB CB CATCH BASIN CIP CAST IRON PIPE CL CENTERLINE CMP CORRUGATED METAL PIPE CO CLEANOUT CATV CATV COMMUNICATIONS DIAM DIAMETER DIP DUCTILE IRON PIPE EE ELECTRICAL ECR END CURB RETURN EL ELEVATION EVC END VERTICAL CURB EXIST EXISTING FFE FINISHED FLOOR ELEVATION FG FINISH GRADE FH FIRE HYDRANT FL FLOWLINE / FLANGE FM FORCE MAIN G GAS GM GAS METER GB GB HP HIGH POINT L CURVE LENGTH LF LINEAL FEET MH MANHOLE MJ MECHANICAL JOINT PC POINT OF CURVATURE PI POINT OF INTERSECTION PL PROPERTY LINE POB POINT OF BEGINNING POC POINT OF CONNECTION PT POINT OF TANGENCY PVC POLYVINYL CHLORIDE R RADIUS RCP REINFORCED CONCRETE PIPE R/W RIGHT-OF-WAY RD ROOF DRAIN SS SANITARY SEWER SD STORM SEWER STA STATION STEP SEPTIC TANK EFFLUENT PUMP STD DTL STANDARD DETAIL T TELEPHONE TB THRUST BLOCK TC TOP OF CURB TYP TYPICAL UGP UNDERGROUND POWER W WATER WM WATER METER WV WATER VALVE STORmHOUSE YELM 10512 CREEK STREET SE, YELM, WA. 98597 SECTION 29, TOWNSHIP 17, RANGE 2E, W.M. "CALL UNDERGROUND LOCATE AT 811 BEFORE YOU DIG" LEGEND & LINETYPES: EXISTING -----X -----X -----X -----X -----X - -----W-----W-----W-----W-----W- ----- ss ----- ss ----- ss ----- ss — ----- SD ----- SD ----- SD ----- SD — -----G -----G -----G -----G -----G - -----P -----P -----P -----P -----P - ----- OH ----- OH ----- OH ----- OH — ----T-OH-----T-OH-----T-OH -----T -----T -----T -----T -----T - -----C -----C -----C -----C -----C - PROPOSED W W SS SS 1 FM FM 2 SD SD 3 SP -01 G G P P OP OP —T -OH T -OH -----T -----T -----T -----T -----T - RIGHT-OF-WAY LINE PROPERTY LINE CENTERLINE EASEMENT LINE SAWCUT LINE EDGE OF PAVEMENT/CURB LINE EDGE OF GRAVEL LINE SIDEWALK LINE BUILDING LINE FENCE LINE WATER LINE SEWER LINE FORCE MAIN LINE STORM LINE DITCH LINE ROADWAY STRIPE LINE GAS LINE POWER LINE OVERHEAD POWER LINE OVERHEAD PHONE LINE TELEPHONE LINE CABLE/COMMUNICATIONS LINE STORM CATCH BASIN STORM MANHOLE FIRE HYDRANT WATER METER GATE VALVE THRUST BLOCKING WATER BENDS WATER TEE SEWER MANHOLE STORM/SEWER CLEANOUT VICINITY MAP NOT TO SCALE ENTITLEMENT SHEET INDEX SHEET N0. SHEET REF. SHEET DESCRIPTION 1 CV -01 COVER SHEET 2 SV -01 TOPOGRAPHIC SURVEY 3 SP -01 PREL. SITE/PAVING/HORIZ. PLAN 4 SD -02 PREL. GRADING/STORMWATER PLAN 5 UT -01 PREL. WATER/SEWER PLAN 6 7 8 9 - 10 C ENTITLEMENT PLANS: THESE PLANS AREA INTENDED FOR THE CITY OF YELM LAND USE ENTITLEMENT PROCESS. INFORMATION CONTAINED IS INTENDED TO DEMONSTRATE THE FEASIBILITY OF THIS PROJECT AND THAT IT MEETS THE CITY'S REQUIREMENTS. A SEPARATE SET OF CONSTRUCTION DOCUMENTS WILL BE SUBMITTED FOR CONSTRUCTION APPROVAL THAT WILL INCLUDE ALL NECESSARY CONSTRUCTION DETAILS, CITY STANDARD NOTES AND DETAILS REQUIRED FOR CONSTRUCTION APPROVAL. N O N w Q 0 w w Z w J U w co cn 0 0 N w w a vplE C, � OF WASy j2Cf� � c Q �P O O QL o <v 420 10 �FGISTE��Q SSI O N A L 00 2E J LU w Lu >_ = w cn U) 0f 0 Lu O O O U) Lo J W O (J7 O >> 00 FLQQN J=jd� — ~W O ao Qr5c� LLr>� N >_ J 0 J W J m Mo Z DRAWING NO: CV -01 SHEET N0: 1 OF 5 Ln Ln 0 M 00 Ln 00 Q 0 z z w 00 rl x 0 Co 0 N j C) o U N Z - C O ,n N O O rlo O N Lu w coz ~ mJ Lu o co U - 2E J LU w Lu >_ = w cn U) 0f 0 Lu O O O U) Lo J W O (J7 O >> 00 FLQQN J=jd� — ~W O ao Qr5c� LLr>� N >_ J 0 J W J m Mo Z DRAWING NO: CV -01 SHEET N0: 1 OF 5 Ln Ln 0 M 00 Ln 00 Q 0 z z w 00 rl x 0 Co 0 REGISTEREDSTA T E OFWASHINGTONPROFESSIONALLANDS UR V EYOR 4672066,9063935453756,9061,509 SF1,060 EX 12" SD TO REMAIN 10 LF 12 SD 02.0% I SDCB 2088 I SOLID LID RIM 351.16 IE W 12"CPP 344.3 IE S 12"CPP 344.3 510 I ------ -� SEC. 29, Tl 7N., R2E.) W. M. 46 LF 12" PERF NEW TYPE 1 CB 159 LF 12 SD 0 1.2% EX STORM PIPE NEW TYPE 1 CB PIPE 0 0.0% RIM=350.30 TO BE REMOVED RIM=350.27 IE=345.60 IE=344.57 IE=346.47 CONNECT ROOF DRAIN INFILTRATION GALLERY , r ' / I 1132 ti 351.00 RIM 348.72 \ IE W 12"CPP 344.4 1.0% IE E 12"CPP as, as as as as Lu O '43 0 N74lool cn 07 I / -t - -� 351.00 I I Q i 351.00 % / 351.0q ( - / / 350138 U) o I / _ I , 0 = I P_ 51.00 ° I� �-1 "ACO" TRENCH DRAIN 350.38- I I C� CONNECTED TO 2cou� GELINE 1 TYPE -1 CB WITH 6SD 0 2.0% MIN 50.35 350.35 350.751\ rl 7 a _ a 6I II I STORM PIPE UNDER BUILDING TO BE REMOVED CB TYPE 1 RIM=349.80 IE=345.70 / CONNECT ROOF DRAIN I SDCB 2130 - 2.0% RIM 349.88 350.26 IE W 12"CPP 345.6 J 349.80 IE E 12 -CPP 345.5 I I I IE S 12"CPP 345.5 / I I il I _ 0 SII / - 350. EX 12" SD TO REMAIN ° STORM PIPE UNDER BUILDING TO r'REMOVED 351.00 AND CONNEC D FPR IV, ROOF DRAIN 70 RD -IF - 1RD ` 350.80 SDCB 2274 RIM 349.32 IE E 12"CPP 346.5 0 0 C) w cD Of0 V) N m J W } O O V) ZDZD 0 M •- O Q' N E N � U O EcD nz NF -- _j LN N Z 0 U ku ku i 4X40 X4 DEEP I, W/4" PERF 12" PERF PIPE STORMATER TREATMENT AQUA -SWIRL AS -2 RIM=350.25 IE=345.60 TREATS 4,018 SF ASPHALT AREA -a a a- a i 351.00 o �s, w � Z _ J \ \ I D 351.00/ 0 35109 I } 00 351.00 RIDGELINE I I I / -/7S D/C /B 1 3 I I I RIM 350.64 I I 1 IE W 6"PVC 347.5 350.50 I 35 150 I I i 1 IE E 6"PVC 347.5 1 -4 F. -. J - - STORM PIPE UNDER ' BUILDING TO BE REMOVED ' ---1���----. ----- r- --- -' I I I I I EX CB TO BE REMOVED D SDCB 1306 RIM 349.90 IE N 12 -CPP 346.1 FF -351.00 1 ' I I 351.00 PSE NATURAL GAS CONNECTION EX CB TO BE REMOVED SDCB 1229 RIM 349.94 -D IE S 12"CPP 347.2 STORM PIPE UNDER BUILDING TO BE REMOVED 6" ROOF DRAIN SYSTEM / AND CAPPED 66' NORTH TO BE COORDINATED WITH ( OF EX CB DOWNSPOUT LOCATIONS ON NEW TYPE 1 CB SDCB 1132 ti RIM=350.18 IE=345.68 RIM 348.72 \ IE W 12"CPP 344.4 CD IE E 12"CPP 344.4 I /� Lu O N74lool cn 07 O 0 -t - -� W 30.50 Lo / 350138 U) o I / _ Q , 0 = I P_ 0 �-1 C 350.38- uj C� -I� �.350 2cou� 0 1 z P- � >� Q 0 1 w N c� 0 35 .50 350 70 -- ° I w J Lu Lu i. Q:• . - .. .. . . Dc 351.00 351.20 d (I 351.00 351.35 WEST SIDE OF BLDG. ' .D RC RD Pn -ons �rS pv -R[)- -RD CREEK ST SE 3.20,L9. I ON PLAN VIEW: 1" = 20' HORIZ. SDCB 2308 RIM 350.82 IE S 12"DI 348.4 351.70 `L 350.30 f 2-07 - I I 351.00 -GAS-GAS GAS- ' qI D D i• I - - r. 2.0% 1352.50 .I_•. Y 1 - � � \ N ° II I II 1 EX CB TO REMAIN 0' 20' 40' EX 12" SD TO REMAIN SCALE 1" = 20' HORIZONAL DATUM: HORIZONTAL - WASHINGTON STATE PLANE COORDINATES, SOUTH ZONE, NAD 83/2011 BASED ON GPS TIES TO MONUMENTS USING WASHINGTON STATE REFERENCE NETWORK. N 1'57'03" E ON WEST LINE OF SECTION 29. VERTICAL DATUM: VERTICAL - NAVD 88 BASED ON GPS TIES TO MONUMENTS USING WASHINGTON STATE REFERENCE NETWORK. SDCB 1026 RIM 350.68 I IE N 12"CPP 347.1 IE W 12"CPP 347.2 IE E 12"CPP 347.1 EX CB TO REMAIN N. PIPE USED FOR ROOF DRAIN CONNECTION EX 12" SD TO REMAIN SDCB 1571 RIM 352.06 IE N 12"DI 348.3 IE E 12"CPP 348.2 EX CB/P� REMAIN -l000 ENTITLEMENT PLANS: THESE PLANS AREA INTENDED FOR THE CITY OF YELM LAND USE ENTITLEMENT PROCESS. INFORMATION CONTAINED IS INTENDED TO DEMONSTRATE THE FEASIBILITY OF THIS PROJECT AND THAT IT MEETS THE CITY'S REQUIREMENTS. A SEPARATE SET OF CONSTRUCTION DOCUMENTS WILL BE SUBMITTED FOR CONSTRUCTION APPROVAL THAT WILL INCLUDE ALL NECESSARY CONSTRUCTION DETAILS, CITY STANDARD NOTES AND DETAILS REQUIRED FOR CONSTRUC77ON APPROVAL. m N 0 N ui Q cn 0 w w Z w J U w CL co 0 0 c N Lu w a *pp� f'C7 F OF WASy,G�'j� � c �P 0 o o � �F42010 GISTE SSI O N A L N Lu CD �� O Q /� Lu O N74lool cn 07 O 0 I > II Lo N U) o 0 II I II 1 EX CB TO REMAIN 0' 20' 40' EX 12" SD TO REMAIN SCALE 1" = 20' HORIZONAL DATUM: HORIZONTAL - WASHINGTON STATE PLANE COORDINATES, SOUTH ZONE, NAD 83/2011 BASED ON GPS TIES TO MONUMENTS USING WASHINGTON STATE REFERENCE NETWORK. N 1'57'03" E ON WEST LINE OF SECTION 29. VERTICAL DATUM: VERTICAL - NAVD 88 BASED ON GPS TIES TO MONUMENTS USING WASHINGTON STATE REFERENCE NETWORK. SDCB 1026 RIM 350.68 I IE N 12"CPP 347.1 IE W 12"CPP 347.2 IE E 12"CPP 347.1 EX CB TO REMAIN N. PIPE USED FOR ROOF DRAIN CONNECTION EX 12" SD TO REMAIN SDCB 1571 RIM 352.06 IE N 12"DI 348.3 IE E 12"CPP 348.2 EX CB/P� REMAIN -l000 ENTITLEMENT PLANS: THESE PLANS AREA INTENDED FOR THE CITY OF YELM LAND USE ENTITLEMENT PROCESS. INFORMATION CONTAINED IS INTENDED TO DEMONSTRATE THE FEASIBILITY OF THIS PROJECT AND THAT IT MEETS THE CITY'S REQUIREMENTS. A SEPARATE SET OF CONSTRUCTION DOCUMENTS WILL BE SUBMITTED FOR CONSTRUCTION APPROVAL THAT WILL INCLUDE ALL NECESSARY CONSTRUCTION DETAILS, CITY STANDARD NOTES AND DETAILS REQUIRED FOR CONSTRUC77ON APPROVAL. m N 0 N ui Q cn 0 w w Z w J U w CL co 0 0 c N Lu w a *pp� f'C7 F OF WASy,G�'j� � c �P 0 o o � �F42010 GISTE SSI O N A L Z EJB] DRAWING NO: SD -01 SHEET N0: 4 of 5 Ln r -I r -I Ln O m 00 Ln 00 Q z z LLI 00 rl x O m O n N Lu CD O Q N Lu O cn 07 O 0 I > II Lo N U) o 0 _ Q n J = 0 = C F_ uj C� � 2cou� 0 z P- � >� Q 0 4 w N c� 0 N � � w J Lu Lu L�LI 0- 0 m m J CJ Z Z Q co J DLL Z EJB] DRAWING NO: SD -01 SHEET N0: 4 of 5 Ln r -I r -I Ln O m 00 Ln 00 Q z z LLI 00 rl x O m O n Lu Q J Lu O UJ 07 O 0 > rn Lo � U) LLQQNo Q C) J = = - F_ uj C� � 2cou� z P- � >� Q >_"_J� 4 w N c� 0 co w J Lu J 00 0- 0 Z EJB] DRAWING NO: SD -01 SHEET N0: 4 of 5 Ln r -I r -I Ln O m 00 Ln 00 Q z z LLI 00 rl x O m O n 4° 45' WM BEND 4" 45' WM BEND EX WATER MAIN TO REMAIN 4" 90' BEND NEW 4" LIVE TAP FOR FIRE SUPPLY NEW 4" FDC FIRE LINE FOR STORAGE CENTER NEW 4° FDC FIRE LINE FOR APARTMENT REMOVE AND CAP EX FIRE HYD CONNECTION I INSTALL RELOCATED FDC FOR APARTMENT INSTALL NEW FDC FOR STORAGE CENTER INSTALL RELOCATED FIRE HYDRANT r 0 0 i w c� Of 0 V) N J W } O O V) ZDZD 0 M •� O .E � U O ;_ i aZ F -- Lo (n --oN N Z 0 U CONNECT NEW FDC FIRE I" '%'19. LINE FOR APARTMENT 3 I 3 - 3 3 3 3117 .p 3 � 3 f3 CONNECT 4" FIRE DEPARTMENT CONNECTION SUPPLY LINE w w 0. 3 CONNECT 4" FIRE SPRINKLER 3 I 9 SUPPLY LINE. 660 3 EX WATER METER SETTER 3 ° TO REMAIN. PROTECT, INSTALL NEW METER BOX FOR INSTALLATION IN 3 CONCRETE SIDEWALK a 3 I REMOVE EX FIRE SYSTEM °O PIPING FOR APARTMENT x I 3 ° RELOCATE EX FDC AND FIRE PIPING FOR �. APARTMENT —w—j- EX FIRE HYDRANT TO BE RELOCATED ® INSTALL IRRIGATION WATER V. METER, SETTER AND DDCV BACKFLOW PROTECTION ° ° FIRE SPRINKLER SYSTEM DOUBLE CHECK VALVE TO BE LOCATED INSIDE RISER ROOM SEC. 29, T17N., R2E., W.M. S S S S REMOVE AND RELOCATE 2" EX 2" SS STEP MAIN STEP MAIN END OF LINE TO BE REMOVED CLEANOUT CREEK ST SE 0 INSTALL 6" SIDE SEWER PIPE AND CLEAN OUT INSTALL 6" GRAVITY SIDE SEWER AND CLEAN OUT INSTALL 3,000 GALLON CONCRETE STEP TANK AND DUPLEX PUMP SYSTEM INSTALL STEP CONTROL PANEL INSTALL STEP SERVICE - CARSON BOX IN LANDSCAPE AREA S S S S S S S S S S 3S0,L9. L0N PLAN VIEW: 1" = 20' HORIZ. REINSTALL 2" STEP SEWER END OF LINE CLEAN INSTALL 1" STEP SERVICE CONNECTION TO 2" MAIN i W Wim- W W EX WM W W EX STEP SEWER MAIN S S S S S S S N N 0' 20' 40' Q J` 3I EX 8" WATER MAIN � w W 4::L TO REMAIN 0) o [7-77- SCALE 1" = 20' LL Q Q Lo cn = N � co 0 0 a: ® EX WATER METER AND p < f cp 3 SETTER TO BE REMOVED jLO Q D CAPPED C� p�COw �J HORIZONAL DATUM: EX APARTMENT J w m FDC FIRE LINE TO HORIZONTAL - WASHINGTON STATE PLANE ,? 3 REMAIN COORDINATES, SOUTH ZONE, NAD 83/2011 BASED ON GPS TIES TO MONUMENTS USING WASHINGTON STATE w �! INSTALL RELOCATED WATER REFERENCE NETWORK. METER, SETTER AND RPBA N 1'57'03° E ON WEST LINE OF SECTION 29. w 3 BACKFLOW PROTECTION CL VERTICAL DATUM: z c/) Z 0 EX 2 STEP MAIN TO W w REMAIN VERTICAL - NAVD 88 BASED ON GPS TIES TOOf MONUMENTS USING WASHINGTON STATE REFERENCE a NETWORK. N �cVWARD LLJ N(n �� OF WAS/-/ j2Gf0 — oo _ 04�, vS Q c� S o w x Z z 3 EX STEP TEE ANDo 42010N40 �FGISTE SSI S GATE VALVE TO 0 N A L REMAIN 3 � o 3 — 0 N 0 0 II \ N I oM o 3 I o 0 0 cn -ro EX FDC FOR o N 3 APARTMENTSw w m co W CJ Z 3 N I I EX FIRE HYDRANT o o u- ® 3 N 1 3 — w w w w�-- — S S S S S S S c ENTITLEMENT PLANS: THESE PLANS AREA INTENDED FOR THE CITY OF YELM LAND USE ENTITLEMENT PROCESS. INFORMATION CONTAINED IS INTENDED TO DEMONSTRATE THE FEASIBILITY OF THIS PROJECT AND THAT IT MEETS THE CITY'S REQUIREMENTS. A SEPARATE SET OF CONSTRUCTION DOCUMENTS WILL BE SUBMITTED FOR CONSTRUCTION APPROVAL THAT WILL INCLUDE ALL NECESSARY CONSTRUCTION DETAILS, CITY STANDARD NOTES AND DETAILS REQUIRED FOR CONSTRUCTION APPROVAL. z Q J` �wt' � w W 00o 0) o w u:) LL Q Q Lo cn = � co 0 0 a: -6 p < f cp Of � ) jLO Q C� p�COw �J J m M, Z EJB] DRAWING NO: UT -01 SHEET NO: 5 OF 5 Ln r -I r -I Ln O m m 00 Ln 00 m Q z z W 00 rl x 0 rn0 d