Loading...
2021.0362MP0100 Yelm - Burger 21870 HP equip specs - site planTRANE° Submittal Side Discharge Variable Speed HP For coastal applications where units are installed within one (1) mile of salt water, epoxy coated models are recommended. These models have an 8 week lead time after order. 4T W L9036A 1000A Epoxy Coated Model 4TWL9036A1 COTA Note: "Graphics in this document are for representation only. Actual model may differ in appearance." March 2020 4TWL9036A-SUB-1 C -EN 1 TecZ n N= Iuo �ocies T/PNYE' Product Specifications OUTDOOR UNIT (e) (b) 4TWL9036A1XXXA POWER CONKS. — V/PH/HZ W 208-230/1/60 MIN. BRCH. CIR. AMPACITY 26.9 BR. CIR. PROT. RTG. — MAX. (AMPS) 30 COMPRESSOR CLIMATUFF®- SCROLL NO. USED — NO. STAGES 1— Variable VOLTS/PH/HZ 208-230/1/60 R.L. AMPS (d)/ L.R. AMPS 12.4/48.9 FACTORY INSTALLED 70.37 START COMPONENTS (e) NO INSULATION/SOUND BLANKET YES SUMP HEAT YES OUTDOOR FAN PROPELLER DIA. (IN.) — NO. USED 27.5-1 TYPE DRIVE — NO. SPEEDS DIRECT — VARIABLE CFM @ 0.0 IN. W.G. M 2400 NO. MOTORS — HP 1-1/2 MOTOR SPEED R.P.M. 200-1050 VOLTS/PH/HZ 325-385 VDC/3/60 F.L. AMPS 2.3 OUTDOOR COIL — TYPE PLATE FIN ROWS—F.P.I. 2-16 FACE AREA (SQ. FT.) 12.88 TUBE SIZE (IN.) 5/16 REFRIGERANT LBS. — R -410A (O.D. UNIT) (9) 8 LBS, 0 OZ FACTORY SUPPLIED YES LINE SIZE — IN. O.D. GAS (h) 3/4 UNE SIZE — IN. O.D. LIQ. 3/8 CHARGING SPECIFICATIONS SUBCOOLING — COOLING MODE 10° F DIMENSIONS H X W X D CRATED (IN.) 42 x 56 x 24 UNCRATED (IN.) 36-3/4 X 47 X 17-1/2 WEIGHT SHIPPING (LBS.) 250 NET (LBS.) 226 (a) Certified in accordance with the Air -Source Unitary Air -conditioner Equipment certification program, which is based on AHRI standard 210/240. (b) Rated in accordance with AHRI standard 275. (0 Calculated in accordance with Nati. Elec. Codes. Use only HACR circuit breakers or fuses. (d) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current. M No means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter. Optional kit shown. M Standard Air — Dry Coil — Outdoor (9) This value approximate. For more precise value see unit nameplate. (h) Reference the outdoor unit ship -with literature for refrigerant piping length and lift guidelines. Reference the refrigerant piping software pub # 32-3312-xx or refrigerant piping application guide SS- APG006-xx for long line sets or specialty applications (xx denotes latest revision). Center Mass Dimensions Model 2 Ton 3 Ton 4/5 Ton Total Weight 206 228 247 W1 (LB) 135.63 143.03 150.35 Dim "A" 13.75 15.00 15.75 W2 (LB) 70.37 84.97 96.65 Dim "B" 26.50 25.25 24.50 4TWL9036A-SUB-1 C -EN TRANE. Outline Drawing A PICI;U RE At EPSs ISE . U 111 FIN alt All RRs 1 it Fttn 1400 SURIORtDIK, SCUM a Ail SIDES am 1Call 1111Ster ICE r4rE. 61 Lk( tint C061110101, RIS. 1/4• SN RI.Rt ►tisumt to follow$ Putt + Hi T 64S to%E 114 TOtt Jell Sm.cl rltrl. J 1 0 FE.41 JtARD COW -106 "ll" N1' s.t G• 1111( ►elflull TN W1114 FIGURE 2 m I 111ho'm las 11t1 sltllcE Uu1l. --j �F^J 1. 1 D Flout 6111tH to-MC11a111=1.014.p UE 'I G FIGURE I H F t Model CONIFOeM CU�taKESOt1a1t A RER FetrlltoING CODES C IW ID lilt SLAV ICE F telt!. � I.D. tlxlll K .1 1. $ACtlOo 111 11M uff Sal 11 IR[SSOtI Tu iI1111`6 las 11t1 sltllcE Uu1l. --j �F^J 1. 1 D Flout 6111tH to-MC11a111=1.014.p UE 'I G FIGURE I H F t Model Base A B C D E F G H J K 4TWL9036A 4.3 934 (36-3/4) 1194 (47) 445 (17-1/2) 16 10 (3/4) (3/8) 54 (16)/ 159 101 187 (6-1/4) (33 / (7-11/32) 495 (19-1/2) 4TWL9036A-SUB-1 C -EN 3 0 MANE Sound Pressure Level Outdoor Unit 3' ft 5' ft Table 1. 3.0 Ton Heating Reflective Surface (Back wall) (a) Lab tested as per the illustration shown above Table 2. 3.0 Ton Cooling Sound Pressure Level dB(A) per ARI 275 (Max Heating) # Reflective Surfaces 3 51 7 from Property Line from Property Line from Property Line 0 46 41 1 490) 44 2 52 47 44 (a) Lab tested as per the illustration shown above Table 2. 3.0 Ton Cooling (a) Lab tested as per the Illustration shown above Notes: • Measuring place: Hemi -Anechoic chamber • Sound pressure level will vary depending on a range of factors such as the construction of the particular room where the equipment is installed. • Operation sound level may differ depending on operation and ambient conditions. 4TWI9036AI Sound Characteristics Oaa9n —IIotW 0 i _1 I }�a Af a$ I 9 i 3 E 0 10 a 10 W 100 %Derlehd 4 4TW L9036A-SUB-1 C -EN Sound Pressure Level dB(A) per ARI 275 (Max Cooling) # Reflective Surfaces 3 51 7 from Property Line from Property Line from Property Line 0 45 1 481+) 43 2 51 46 43 (a) Lab tested as per the Illustration shown above Notes: • Measuring place: Hemi -Anechoic chamber • Sound pressure level will vary depending on a range of factors such as the construction of the particular room where the equipment is installed. • Operation sound level may differ depending on operation and ambient conditions. 4TWI9036AI Sound Characteristics Oaa9n —IIotW 0 i _1 I }�a Af a$ I 9 i 3 E 0 10 a 10 W 100 %Derlehd 4 4TW L9036A-SUB-1 C -EN TRMWE' Mechanical Specification Options General The outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit, ten (10) feet of tested connecting line, and the smallest rated indoor evaporative coil match. This unit is designed to operate at outdoor ambient temperatures from 55° F to 120° F in cooling. From — 10° F to 66° F in heating. Only AHRI approved indoor matches are approved for use with these models. This outdoor unit contains the ComfortLinki" II digital communication with 2 wire connection to outdoor and Plug -n -Play set up. Casing Unit is painted with a glossy corrosion resistant finish on all panels. Refrigerant Controls Refrigeration system controls include condenser fan, high and low pressure switches. A factory supplied, field installed filter drier is standard. 4TWL9036A-SUB-1 C -EN Compressor Inverter driven scroll compressor with 50 to 100% output capacity. Noise enclosure minimizes sound levels and built in compressor protection will reduce operating speed and current draw to maintain operation while protecting the compressor. Condenser Coil The copper tube, aluminum fin outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected by a wire guard. Low Ambient Cooling As manufactured, this system has built in freeze protection that will allow cooling operation down to 45° F but will reduce capacity or shut down completely to prevent operation under adverse conditions. Comfort Control The 10501950/850 Control is required and provides Plug -n -Play setup and 3 wire connection. aTRANS' Trane - by Trane Technologies (NYSE: TT), a global climate innovator - creates comfortable, energy efficient indoor environments for commercial and residential applications. For more information, please visit trane.com or tranetech nolog ies.com. C UL US LISTED The AHRI Certified mark indicates Trane U.S. Inc. participation in the AHRI Certification program. For verification of individual certified products, go to ahridirectory.org. Trane has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. 4TWL9036A-SUB-IC-EN 31 Mar 2020 Supersedes 4TWL9036A-SUB-IB-EN (July2018) 02020 Trane Date: 1� Address: Homeowner: Burger HEAT PUMP SITE PLAN, 10005 cole ct se Job #: a► S'7tt --- Property line to Building: 30 _ft Property line to Equipment: 28 ft Rear Property Front Property f� B