Loading...
2021.0383.BP0027 WYNDSTONE YELM GARAGES 06.26.20TAHOMA BOULEVARD SOUTHEASTTORNADO ALLEYTERRA VIEW ST SE 99TH AVE. SE. 99TH WAY SE. 100TH AVE SE TERRA GLENN STREET SOUTHEASTBERRY VALLEY ROAD SOUTHEAST LONGMIRE STREET SOUTHEAST 100TH AVENUE SO U THEAST L ON GMI R E S T R E E T S OU T H E A S T DURANT ST SE6" MIN.1. APPLICABLE CODES AND REQUIREMENTS: 2015 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL MECHANICAL CODE 2015 INTERNATIONAL UNIFORM PLUMBING CODE 2015 INTERNATIONAL FIRE CODE 2015 INTERNATION ENERGY CONSERVATION CODE 2017 WASHINGTON CITIES ELECTRICAL CODE 2009 ICC A117.1 - ACCESSIBILITY CODE 2. OCUPANCY CLASSIFICATION AND REQUIREMENTS: OCCUPANCY GROUP U (GARAGES) 3. TYPE OF CONSTRUCTION: GARAGE, SINGLE STORY NON-SPRINKLED (NS) TYPE 5B 4. GENERAL BUILDING LIMITATIONS: 1. Max. bldg. height per table 504.3: U=40' Proposed total bldg. height 15'-0" NOTE: NFPA 13R NOT PERMITTED FRONTAGE INCREASE PER 506.3 BUILDING 1F = [ F/P - .25 ] W/30 1F = [ 143/143 - .25 ] 30/30 1F = [ 1 - .25 ] 1 1F = [ .75] 1 1F = .75 GARAGE (U OCCUPANCY) SEPARATED PER 508.4 Aa = [ At + (NS X 1f) ] x Sa Aa = [ 8,500 + (8,500 x .75) ] x 3 Aa = [ 8,500 + (6,375) ] x 3 Aa = [ 14,875 ] x 3 Aa = 44,625 SF TOTAL ALLOWABLE GARAGE AREA (U OCCUPANCY) 923 SF < 44,625 SF OK (360) 867-1945 E-mail: LJBDesigns@Comcast.net LJB DESIGNS, LLC Olympia, Wasington 98501 111 Market Street N.E., Suite 325 PHONE: 360-528-0513 1910 EAST 4TH AVENUE PMB #170 OLYMPIA, WA 98506 JOSH@REVIVALARCHITECTS.COM REVIVAL ARCHITECTURE DESIGN G:\.shortcut-targets-by-id\1-QMDAB2XbnniJJU3DwuOJPlGSUIXGyBx\2019 Projects\19-027 Peterson Apartments\Revit\WYNDSTONE YELM GARAGES.rvt6/26/2020 1:12:46 PMA0.015025 TAHOMA BLVD SE YELM, WAWYNDSTONE GARAGES - YELM COVER SHEET VACINITY MAP N.T.S. ARCHITECTURAL DRAWING INDEX SHEET # SHEET NAME A0.0 COVER SHEET A2.1 FLOOR PLAN, RCP, ROOF PLAN, SECTIONS & EXTERIOR ELEVATIONS LJB DESIGNS 111 MARKET STREET NE, SUITE 325 OLYMPIA, WASHINGTON 98501 TEL: 360-867-1945 FAX: 360-943-4100 E-MAIL: ljbdesigns@comcast.net CONTACT: LOREN BURK ELECTRICAL DESIGN XXXXXXXX XXXXXXXXXXXX XXXXXXXXXX TEL: XXXXXXXXXX FAX: XXXXXXXX E-MAIL: XXXXXXXXX CONTACT: XXXXXXXXXXXXX STRUCTURAL ENGINEER XXXXXXXXXXXXXXX XXXXXXXXXXX XXXXXXX TEL: XXXXXXX E-MAIL: XXXXXXXXXXXXX CONTACT: XXXXXXXXXX REG. NO. XXXXXXXXXXX OWNER PETERSON BROTHERS, LLC 15025 TAHOMA BLVD SE YELM, WA TEL: FAX: EMAIL: CONTACT: CONTRACTOR XXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXX XXXXXXXXXXXX TEL: XX FAX: XX EMAIL: XXX CONTACT: XXXX ARCHITECTURE REVIVAL ARCHITECTURE DESIGN JOSH S. 1910 EAST 4TH AVENUE PMB #170 OLYMPIA, WA 98506 TEL: 360-528-0513 E-MAIL: JOSH@REVIVALARCHITECTS.COM CONTACT: JOSH S. LIC. # XXXXXX CIVIL ENGINEER XXXXXXXXXXXXXXX XXXXXXXXXXXX XXXXXXXX TEL: XXX CELL: XXXXXXX E-MAIL: XXXXXXXXX CONTACT: XXXXXXXXX 1 1/2" = 1'-0"2 WALL TYPE 2 1 1/2" = 1'-0"5 WALL TYPE 5 ROOF FRAMING @24" O.C. ARCHOR BOLT PER STRUCT. (2) LAYERS 5/8 TYPE 'X' GWB PER GA FILE RC2602 5/8" TYPE 'X' GWB P.T. 2x6 PLATE CONC.FOUNDATION PER STRUCTURAL BATT INSUL. (R-21) 2x6 STUDS @16" O.C. GA FILE # WP8105 HARDIE BOARD & BATTEN SIDING OVER RAIN SCREEN OVER TYVEK OR EQUIVALENT OVER 5/8" TYPE 'X' GWB OVER 1/2" PLYWOOD PER STRUCTURAL ARCHOR BOLT PER STRUCT. CONC.FOUNDATION PER STRUCTURAL GA FILE # WP3605 5/8" TYPE 'X' GWB 5/8" TYPE 'X' GWB ROOF FRAMING @24" O.C. 2x4 STUDS @16" O.C. P.T. 2x4 PLATE NOTE: PROVIDE RAINSCREEN PER MFR. RECOMMENDATIONS (2) LAYERS 5/8 TYPE 'X' GWB PER GA FILE RC2602 Fire Test: FM FC 172, 2-25-72; ITC, 8-6-98 Weight: 5psf Approx. Ceiling GYPSUM BOARD, STEEL JOISTS, ROOF COVERING GA FILE NO. RC 2602 1 HOUR FIRE Base layer 5/8" type X gypsum wallboard applied at right angles to wood trusses 24" o.c. with 1-1/4" type W or S drywall screws 24' o.c. Face layer 5/8" type X gypsum wallboard or gypsum veneer base applied at right angles to joists with 1-7/8" Type W or S drywall screws 12" o.c. at joints and intermediate trusses and 1-1/2" type G drywall screws 12" o.c. placed 2" back on either side of the end joints. Joints offset 24" from base layer joints. Wood trusses supporting 1/2" wood structural panels applied at right angles to trusses with 8d nails. Appropriate roof covering. Ceiling provides one hour fire resistance protection for trusses. GENERIC REVISIONS # ISSUED DATE 11 City Revision 11 4-29-2 0 11 A2.1 A A2.1 B A2.1 C 20' - 0"12' - 6 3/4"12' - 2"12' - 2"12' - 3 1/4" 11' - 10 1/2"11' - 10 1/2" 5 2 222 55 10' x 8' GARAGE DOOR 1' - 3"10' - 2"2' - 0"10' - 2"2' - 0"10' - 2"2' - 0"10' - 2"1' - 3" 11' - 9 3/4"11' - 9 3/4" 49' - 2" 2 A2.1 1 A2.1 2 2 10' x 8' GARAGE DOOR 10' x 8' GARAGE DOOR 10' x 8' GARAGE DOORSLOPETO DRSLOPETO DRSLOPETO DRSLOPETO DRDS DSDS DS 24' - 0"51' - 2" 1' - 0"49' - 2"1' - 0" RIDGE5" / 12"5" / 12"20' - 0"2' - 0"ROOF OVERHANG FIN. FL. 0' - 0" PL. HGT. 9' - 0" HARDIE BOARD & BATTEN SIDING 10' x 8' GARAGE DOOR 2 A2.1 CLASS 'A' ARCTECTURAL ROOFING OVER TITANIUM UDL50 VAPOR BARRIER OVER 1/2" EXT. PLYW'D SHTG. DS DS FIN. FL. 0' - 0" PL. HGT. 9' - 0" HARDIE BOARD & BATTEN SIDING 1 A2.1 CLASS 'A' ARCTECTURAL ROOFING OVER TITANIUM UDL50 VAPOR BARRIER OVER 1/2" EXT. PLYW'D SHTG. DS DS 5" / 12" FIN. FL. 0' - 0" PL. HGT. 9' - 0" HARDIE BOARD & BATTEN SIDING 2 A2.1 CLASS 'A' ARCTECTURAL ROOFING OVER TITANIUM UDL50 VAPOR BARRIER OVER 1/2" EXT. PLYW'D SHTG. DS DS FIN. FL. 0' - 0" PL. HGT. 9' - 0" CLASS 'A' ARCTECTURAL ROOFING OVER TITANIUM UDL50 VAPOR BARRIER OVER 1/2" EXT. PLYW'D SHTG. 5/8" TYPE "X" GWB 2x6 STUDS @ 16" O.C. BATT INSUL (R-21) DOUBLE TOP PLATE ANCHOR BOLT PER STRUCTURAL HEADER PER STRUCTURAL 10' x 8' GARAGE DOOR BATT &/OR BLOWN IN INSUL. (R-49)HARDIE BOARD & BATTEN SIDING OVER RAIN SCREEN OVER TYVEK OR EQUIVALENT OVER 5/8" TYPE 'X' GWB OVER 1/2" PLYWOOD PER STRUCTURAL GRADE PRE MFR. ROOF TRUSSES @ 24" O.C. A2.1 3 FOOTING PER STRUCT. FIN. FL. 0' - 0" PL. HGT. 9' - 0" CLASS 'A' ARCTECTURAL ROOFING OVER TITANIUM UDL50 VAPOR BARRIER OVER 1/2" EXT. PLYW'D SHTG. 5/8" TYPE "X" GWB 2x6 STUDS @ 16" O.C. BATT INSUL (R-21) DOUBLE TOP PLATE ANCHOR BOLT PER STRUCTURAL 5/8" TYPE "X" GWB 2x4 STUDS @ 16" O.C.2x4 STUDS @ 16" O.C. 2x4 STUDS @ 16" O.C. 5/8" TYPE "X" GWB 5/8" TYPE "X" GWB 5/8" TYPE "X" GWB 2x6 STUDS @ 16" O.C. BATT INSUL (R-21) DOUBLE TOP PLATE ANCHOR BOLT PER STRUCTURAL BATT &/OR BLOWN IN INSUL. (R-49)HARDIE BOARD & BATTEN SIDING OVER RAIN SCREEN OVER TYVEK OR EQUIVALENT OVER 5/8" TYPE 'X' GWB OVER 1/2" PLYWOOD PER STRUCTURAL PRE MFR. ROOF TRUSSES @ 24" O.C. GRADE 12" - SHEET IT CAME FROM NOTE: BOTTOM # ON SECTIONS OR DETAIL LEADS BACK TO STUD WALL - SEE PARTITION TYPES SHEET A0.0 PARTITION TYPES - SEE SHEET A0.0 X - X - X - EXTERIOR ELEVATIONS - # IN BOX INDICATES WALL SECTION SHEET WALL SECTION NUMBER DIRECTION OF SECTION DETAIL NUMBER DETAIL SHEET BUILDING SECTION SHEET BUILDING SECTION LETTER DIRECTION OF SECTION DOWNSPOUTDS WHICH PAGE DETAILS IS ON - ARCHITECTURAL SYMBOLS - PL. HGT. 9' - 0" PERFORATED HARDIE SOFFIT PANEL OVER WOOD FRAMING CLASS 'A' ARCHITECTURAL ROOFING OVER TITANIUM UDL50 VAPOR BARRIER OVER 1/2" EXT. PLYWD SHTG. HEADER PER STRUCT. 2' - 0" HARDIE BOARD & BATTEN SIDING OVER RAIN SCREEN OVER TYVEK OR EQUIVALENT OVER 5/8" TYPE 'X' GWB OVER 1/2" PLYWOOD PER STRUCTURAL (360) 867-1945 E-mail: LJBDesigns@Comcast.net LJB DESIGNS, LLC Olympia, Wasington 98501 111 Market Street N.E., Suite 325 PHONE: 360-528-0513 1910 EAST 4TH AVENUE PMB #170 OLYMPIA, WA 98506 JOSH@REVIVALARCHITECTS.COM REVIVAL ARCHITECTURE DESIGN G:\.shortcut-targets-by-id\1-QMDAB2XbnniJJU3DwuOJPlGSUIXGyBx\2019 Projects\19-027 Peterson Apartments\Revit\WYNDSTONE YELM GARAGES.rvt6/26/2020 1:12:47 PMA2.115025 TAHOMA BLVD SE YELM, WAWYNDSTONE GARAGES - YELM FLOOR PLAN, RCP, ROOF PLAN, SECTIONS & EXTERIOR ELEVATIONS 1/4" = 1'-0" FIRST FLOOR PLAN 1/4" = 1'-0" ROOF PLAN 1/4" = 1'-0" REFLECTED CEILING PLAN 1/4" = 1'-0"A FRONT ELEVATION 1/4" = 1'-0"B SIDE ELEVATION 1/4" = 1'-0"C REAR ELEVATION 1/4" = 1'-0" 2 A2.1 SECTION 2 1/4" = 1'-0" 1 A2.1 SECTION 1 SURFACE OR PENDANT MOUNTED LINEAR LUMINAIRE CEILING ELEVATION9' - 0" REFLECTED CEILING PLAN LEGEND DUPLEX RECEPTACLE (110V) REVISIONS # ISSUED DATE 11 City Revision 11 4-29-2 0 1" = 1'-0"3 SOFFIT DETAIL 11 11