Loading...
2021.0418.FR0017 3705 YELM, WA CUT SHEETS 07.26.21Intrusion Systems | D9412GV2 Control Panel The D9412GV2 Control Panel provides an integrated solution for intrusion, access control, and fire alarm system applications. The control panel includes a communicator that sends events to selected public switched telephone network (PSTN) or IP network destinations through four programmable route groups. The control panel provides up to 246 individually identified points. Each point: •Accommodates normally‑open (NO) and normally‑closed (NC) devices with end‑of‑line (EOL) resistor supervision•Is programmable for fire, fire supervisory, or intrusion applications. With the D9412GV2 you can: •Monitor alarm points for intruder or fire alarms while operating user keypads and other outputs•Program all system functions on‑site through a D5200 Programmer or remotely through Remote Programming Software (RPS).•Add up to eight doors of access control using the optional D9210BLC Access Control Interface Module. Functions Programmable Outputs •2 A alarm power at 12 VDC•1.4 A auxiliary power at 12 VDC•Four alarm‑output patterns•Programmable bell test•Programmable bell shut‑off timer System Response •31 custom point indexes, including fire supervisory•Selectable point response time•Cross point capability•Fire alarm verification•Fire inspector’s local test•Watch mode•Scheduled events (skeds) arm, disarm, bypass and unbypass points, control relays, control authority levels, and control door access User Interface •Supervision of up to eight keypads (up to 32 unsupervised keypads can be used)•Custom keypad text•Full function command menu including custom functions•Authority by area and 16‑character name for each user•14 custom authority levels control user’s authority to change, add, or delete passcodes or access control credentials; to disarm or bypass points; and to start system tests Note Use at least one keypad in each system. D9412GV2 Control Panel ▶Fully integrated intrusion, fire, and access control allows users to interface with one system instead of three ▶Conettix IP‑based communication option provides high‑speed, secure alarm transport and control ▶Eight programmable areas with perimeter and interior partitioning ▶246 points with flexible configuration options to meet multiple installation requirements ▶Your choice of vacuum fluorescent or ATM style user interface keypads ▶New user interface functions provide additional security and flexibility ▶Up to 238 RF points www.boschsecurity.com 2 | D9412GV2 Control Panel Area Configurations Area programming offers a wide selection of different system configurations. Each area is assigned an account number to define annunciation, control, and reporting functions. Multiple areas can be linked to a shared area which is automatically controlled (hallway or lobby). Area arming can be conditional on other areas (master or associate). Two Man Rule Two Man Rule provides added security by requiring: •Two people present at opening•Two unique passcodes on the same keypad to disarm an area Without the second passcode, the system denies entry. Early Ambush Early Ambush requires two passcode entries on the same keypad. Enter the same passcode twice or have two unique passcodes, depending on the configuration. The first entry disarms the area and the second entry stops a timer programmed to send a duress event. If the second entry does not occur within the programmed time, the system generates a duress event. Early Ambush allows users to inspect the premises and use the system to confirm that the area is safe to enter, providing added security. Easy Exit Control The D9412GV2 Control Panel changes from one armed state to another armed state without disarming. For example, if you change the state from Master Arm to Perimeter Arm, the control panel complies and reports the change. Easy Exit Control reduces the number of keystrokes, simplifying system operation. Programmable Passcode‑controlled Menu List The system prompts users to enter a passcode prior to viewing the keypad menu. The keypad display shows the user the menu options allowed according to the user’s authority level. Passcode-controlled menus provide users only with the options and information pertinent to them, simplifying system operation. Passcode Follows Scope Use Passcode Follows Scope to restrict passcode arming and disarming to the keypad's immediate local area, even if the keypad can report events from other areas. Passcode Follows Scope simplifies the arming and disarming procedure without limiting any other keypad capabilities. Invisible Walk Test A menu item allows the user to test invisible 24‑hour points within the scope of the keypad without sending a report to the central station. Door‑Activated Custom Function A custom function activates when user credentials are presented to a D9210B door controller's reader. The custom function behaves as though the user performed a function at the keypad associated with the door controller. Passcodes User passcodes contain three to six digits. Assign each user one of 14 customized authority levels in each area. Restrict passcodes to operate only during certain times. The Two Man Rule and Early Ambush options require two passcodes, providing additional security in financial establishments such as banks. Communications The D9412GV2 Control Panel prioritizes and sends reports in BFSK or Modem IIIa2 communications formats to four route groups. Each group has a programmable primary and backup destination. The D9412GV2 works with the Conettix D6600 Communications Receiver/Gateway using a Conettix DX4020 Network Interface Module. When using a DX4020, the D9412GV2 has programmable anti-replay anti- substitution features. The Modem IIIa2 Communications Format, available with Bosch receivers, adds central station reporting capabilities such as: •Individual point numbers and text•Opening or closing reports by area number•Remote programming attempts•Diagnostic reports•User name reports Security and Fire Detection The D9412GV2 Control Panel provides eight on‑board points, and up to 238 additional off‑board points (depending on model and expansion interfaces). You can program individual points to monitor all types of burglar alarms, fire alarms, and supervision devices. Event Log The event log stores up to 1,000 local and transmitted events. The event log includes time, date, event, area, point, and user number. View the event log from a keypad or use RPS to remotely retrieve event information. RPS operators can retrieve events periodically using one phone call, rather than receiving several calls each day. When the event log reaches a programmed threshold of stored events, it can send an optional report to a receiver. Access Control The D9412GV2 provides custom door strike, point shunt and auto disarming response by area. There are 14 panel‑wide access levels with both manual and scheduled control. Store, view, or print access events such as: •Access granted D9412GV2 Control Panel | 3 •No entry•Request-to-enter•Request-to-exit Scheduled Events (Skeds) The internal clock and calendar start individually scheduled events (skeds). Skeds perform functions such as arm or disarm, relay control, or point bypassing. The D9412GV2 Control Panel offers: •40 scheduled events with up to 25 different functions•Eight opening windows and eight closing windows•Eight user windows•Day-of-week, date-of-month, or holiday only schedules•Four holiday schedules of 366 days each (leap year) Fire Test When a user activates Fire Test Mode, the control panel suppresses all reports to the central station. The keypad and annunciator show all testing data. An automatic sensor reset feature saves time; you do not need to reset the sensors manually. At the end of test, the keypad shows the number of untested points. Programming, Diagnostics and Controls Users can program on-site with a D5200 Programmer, or program remotely through RPS. A programmable system passcode prevents unauthorized remote programming. D9412GV2 Control Panels accommodate up to four separate telephone numbers for primary, alternate, and backup receivers for automatic test reports. When resetting alarms or arming or disarming a system, the user is identified by name and number. Certifications and Approvals Region Certification USA UL AMCX: Central Station Alarm Units (UL1610, UL1635), AMCX7: Central Station Alarm Units Certified for Canada (CAN/ULC-S304-M88, UL 1635), AMTB: Control Panels, SIA False Alarm Reduction (ANSI/SIA CP-01-2000), AOTX: Local Alarm Units (UL464, UL609), AOTX7: Local Alarm Units Certified for Canada (CAN/ULC-S303, CAN/ULC-S525), APAW: Police Station Alarm Units (UL365, UL464), APAW7: Police Station Alarm Units Certified for Canada (CAN/ULC - S303, CAN/ULC-S304, CAN/ULC-S525), APOU: Proprietary Alarm Units (UL1076), APOU7: Proprietary Alarm Units Certified for Canada (ULC/ORD-C1076), NBSX: Household Burglar Alarm System Units (UL1023), NBSX7: Household Burglar Alarm System Units Certified for Canada (ULC/ORD-C1023), UOJZ: Control Units, System (UL864, 9th edition), UTOU: Control Units and Accessories - Household System Type (UL985), UTOU7: Control Units and Accessories - Household System Type Certified for Canada (ULC-S545) FM CSFM 7165-1615: 119 and 7170-1615: 145 July 2008 FCC AJ9-MUL-46532-AL-E NYC-MEA 12-92-E, Vol, 15 Canada IC 1294A-GV2 Installation/Configuration Notes Compatible Products Keypads D1260 Series Keypads (D1260, D1260W, D1260R, D1260BLK, D1260B) D720 Series Keypads (D720, D720W, D720R, D720B) D1255 Series Keypads (D1255, D1255W, D1255R, D1255B, D1255RB) D1256 and D1256RB Fire Keypads D1257 and D1257RB Remote Fire Alarm Annun- ciators D279A Independent Zone Control www.boschsecurity.com 4 | D9412GV2 Control Panel Detectors D278S Four‑wire Addressable Detector Base, 12 VDC D285/TH Photoelectric Smoke Detector Heads D298S Addressable Detector Base, 24 VDC D7050 Series Addressable Photoelectric Smoke and Smoke Heat Detector Heads F220‑B6PM/S Addressable Detector Bases with POPITs MX250 Series Smoke Detectors MX775i Addressable PIR Detector MX794i Long Range Multiplex PIR Detector MX934i Addressable PIR Detector MX938i Addressable PIR Detector ZX776Z PIR Detector ZX794Z Long Range PIR Detector ZX835 TriTech Microwave/PIR Detector ZX935Z PIR Detector ZX938Z PIR Detector ZX970 PIR/Microwave Detector Bosch conventional detectors, including Blue Line, seismic, PIR, TriTech PIR Microwave, photoelectric, heat, and smoke. Enclosures D8103 Universal Enclosure D8108A Attack‑resistant Enclosure D8109 Fire Enclosure D9101 Fire Enclosure (large) Magnetic Contacts Bosch magnetic contacts include recessed, termi- nal connection, miniature, overhead door, and sur- face mount. Modules C900V2 Dialer Capture Module D113 Battery Lead Supervision Module D125B Dual Class B Initiating Module D127 Reversing Relay Module D129 Class A Initiating Module D130 Auxiliary Relay Module D185 Reverse Polarity Signaling Module D192C Notification Appliance Circuit Module D192G Notification Appliance Circuit Module D928 Phone Line Switcher D5060 MUX Programmer D8125 POPEX Point Expander D8128D OctoPOPIT Eight‑point Expander D8125MUX Point Expander D8129 Octo‑relay Module D8130 Door Release Module D9127 Series POPIT Modules D9131A Parallel Printer Interface Module D9210BLC Access Control Interface Module DS7432 Eight‑input Remote Module DS7457i Series Single‑zone Multiplex Input Mod- ules DS7460i Two‑input Module DS7461i Single‑input Multiplex Module DS7465i Input and Output Module DX4010i RS‑232 Serial Interface Module Conettix DX4020 Network Interface Module ICP-SDI-9114 SDI Splitter Peripheral Hardware rvm4c Remote Video Module Programming D5200 Series Programmers RPS or RPS‑LITE Remote Programming Software Readers ARD‑R10 iCLASS Mullion Reader ARD‑R40 iCLASS Switchplate Reader ARD‑RK40‑09 iCLASS PIN Reader ARD‑VSMART iCLASS Reader D8201/W Series Low‑profile Readers D8203/W Series Mullion Proximity Readers D8223 Prox Pro Reader D8224 Mullion Reader D8224‑SP Switch Plate Reader D8225 Mini Mullion Reader D8227 Insert Card Reader D8301/W Series Low‑profile Proximity Readers D8302 Vandal‑resistant Reader D8303/W Series Mullion Proximity Readers D8304/W Series Extended Range Proximity Read- ers WP644 Series Waterproof Pass‑through Readers SAFECOM Radio Com- municators SC2104 Series Slave Communicators SC3100 Series Data Transfer Radio Communica- tors SC4000 Series Full Data Transfer Radio Communi- cator Wireless Products D8125INV Wireless Interface FA113 Keychain Remote Control FA116 Executive Programmer FA202 Wireless Smoke Detector and Transmitter FA203S Necklace Pendant Transmitter (single‑but- ton) FA203D Necklace Pendant Transmitter (dou- ble‑button) FA204 Necklace Pendant Transmitter FA205S Belt Clip/Loop Transmitter (single‑button) FA205D Belt Clip/Loop Transmitter (double‑but- ton) FA206DS PIR Transmitter FA206i PIR Transmitter D9412GV2 Control Panel | 5 FA207 Glass Break Detector FA209 Billtrap Transmitter FA210 Universal Transmitter (off‑white) FA210W Universal Wide Gap Transmitter with In- ternal Reed Switch (off‑white) FA216L Low‑temperature Transmitter FA216H High‑temperature Transmitter FA223S Water‑resistant Pendant (white single‑but- ton) FA223D Water‑resistant Pendant (black dou- ble‑button) FA250 High‑power Universal Transmitter FA400 Remote Receiver FA404R Transmitter Receiver FA416R Transmitter Receiver FA570 High‑power Indoor Repeater FA575 High‑power Indoor/Outdoor Repeater Parts Included D9412GV2 Components Quantity D9412GV2 Board 1 Mounting Skirt 1 Faceplate with D9412GV2 Label 1 Technical Specifications Communications SDI Bus A (+): 9 VDC 4572 m (15,000 ft) SDI Bus B (-): 9 VDC 4572 m (15,000 ft) Telephone Connection: •One telephone line•D928 Dual Phone Line Module required for two telephone lines Environmental Considerations Relative Humidity:5% to 93% at +30°C (+86°F), non‑con- densing Temperature (Operating): 0°C to +50°C (+32°F to +122°F) Number of… Areas:8 Card Readers (Doors): 8 Credentials (Tokens):996 Custom Functions:16 Events:Up to 1000 Passcode Users:249, plus 1 service passcode Parallel Printers:3 Points:246 (8 on‑board, up to 238 off‑board) Programmable Relay Outputs: 131 RF Points:238 SKEDs:64 Power Requirements Current Draw (Maximum): 300 mA Output (Alarm):2 A at 12 VDC Output (Auxiliary, Continuous Pow- er, and Switched Auxiliary com- bined): 1.4 A at 12 VDC nominal Voltage (Operating):12 VDC nominal Voltage (AC):16.5 VAC 40 VA plug‑in transformer (D1640) Ordering Information D9412GV2 Control Panel Includes one printed circuit board (PCB). D9412GV2 D9412GV2 Control Panel for Canada For use in Canada. Includes one printed circuit board (PCB) and assorted installation hard- ware. D9412GV2-CA D9412GV2 Attack‑Resistant Kit Contains one PCB, one transformer, and one attack-resistant enclosure. D9412GV2-A D9412GV2 Attack‑Resistant Kit for Canada For use in Canada. Contains one PCB, one transformer, and one attack-resistant enclo- sure. D9412GV2-CA-A Ordering Information D9412GV2 Fire and Burglar Kit Contains one PCB, one dual battery harness, two telephone cords, one telephone line switcher, one transformer, and one fire enclo- sure. D9412GV2-B D9412GV2 Commercial Burglar Kit Contains one PCB, one lock and key set, one transformer, and one universal enclosure. D9412GV2-C D9412GV2 Commercial Burglar Kit for Canada For use in Canada. Contains one PCB, one lock and key set, one transformer, and one univer- sal enclosure. D9412GV2-CA-C www.boschsecurity.com 6 | D9412GV2 Control Panel Ordering Information Accessories ICP-SDI-9114 SDI Splitter Provides the ability to set up two independent SDI buses from a single SDI connection on the control panel. ICP-SDI-9114 D928 Dual Phone Line Switcher Allows the control panel to operate over and supervise two separate phone lines. Only one D162 phone cord is supplied. Two additional D161 or D162 phone cords are required. D928 D110 Tamper Switch Screw‑on tamper switch that fits all enclo- sures. Shipped in packages of two. D110 ICP‑EZTS Dual Tamper Switch Combination tamper switch with a wire loop for additional tamper outputs. ICP-EZTS D101 Lock and Key Set D101 D122 Dual Battery Harness Harness with circuit breaker. Connects two batteries to a compatible control panel. D122 D122L Dual Battery Harness with Long Leads Color-coded harness with circuit breaker and leads measuring 89 cm (35 in.). Connects 12 V batteries to compatible control panels. D122L D126 Standby Battery (12 V, 7 Ah) Sealed lead‑acid standby and auxiliary re- chargeable power supply. D126 D1218 Battery (12 V, 18 Ah) A 12 V sealed lead‑acid battery for standby and auxiliary power with two bolt‑fastened termi- nals. Includes hardware for attaching battery leads or spade connectors D1218 D1224 Battery (12 V, 26‑28 Ah) A 12 V sealed lead‑acid battery for standby and auxiliary power with two bolt‑fastened termi- nals. Includes hardware for attaching battery leads or spade connectors. D1224 D1238 Battery (12 V, 38 Ah) A 12 V sealed lead-acid battery for standby and auxiliary power with two bolt‑fastened termi- nals. Includes hardware for attaching battery leads or spade connectors. D1238 D137 Mounting Bracket Used to mount accessory modules in D8103, D8108A, and D8109 enclosures. D137 D138 Mounting Bracket, Right Angle Used to mount accessory modules in D8103, D8108A, and D8109 enclosures. D138 D1640 Transformer D1640 Ordering Information D1640 Transformer for Canada For use in Canada. System transformer rated at 16.5 VAC, 40 VA. D1640-CA D8004 Transformer Enclosure For applications such as fire alarm that might require a transformer enclosure. D8004 D8103 Enclosure D8103 D8108A Attack Resistant Enclosure Grey steel enclosure measuring 41 cm x 41 cm x 9 cm (16 in. x 16 in. x 3.5 in.). UL Listed. Includes lock and key set. Requires the D2402 Mounting Plate. D8108A D8109 Fire Enclosure Red steel enclosure measuring 40.6 cm x 40.6 cm x 8.9 cm (16 in. x 16 in. x 3.5 in). UL Listed. Includes a lock and key set. D8109 D9101 Fire Enclosure Large red enclosure for fire applications. It is constructed of 16 gauge (1.5 mm) cold rolled steel and measures (H x W x D) 37.4 in x 23.5 in. x 2.4 in. (94.8 cm x 59.6 cm x 10.5 cm). D9101 D9002‑5 Mounting Skirt D9002-5 Software Options RPS Kit (LPT) Account management and control panel-pro- gramming software with LPT connection. D5500C-LPT RPS Kit (USB) Account management and control panel-pro- gramming software with USB connection. D5500C-USB Americas: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 security.sales@us.bosch.com www.boschsecurity.us Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com Asia-Pacific: Robert Bosch (SEA) Pte Ltd, Security Systems 38C Jalan Pemimpin Singapore 577180 Phone: +65 6319 3453 Fax: +65 6319 3499 apr.securitysystems@bosch.com www.boschsecurity.com Represented by © Bosch Security Systems Inc. 2009 | Data subject to change without notice T1990236427 | Cur: en-US, V9, 12 Feb 2009 Fire Alarm Systems | D1256 Fire Keypad The D1256 Fire Keypad is a full-function system controller and annunciator. Four one-touch function keys provide user-friendly control over the system. The function keys allow the user to silence the audible alarm output, silence the trouble sounder, reset the annunciator display, and reset the system detectors. Four additional navigational keys allow access to other programmed system functions. The D1256 can be mounted in secure areas. Certifications and Approvals Listings and UL AMCX: Central Station Alarm Units (UL1610) Approvals: UL APAW: Police Station Alarm Units (UL365) UL APOU: Proprietary Alarm Units (UL1076) UL NBSX: Household Burglary Alarm System Units (UL1023) UL UOXX: Control Unit Accessories, System (UL864) UL UTOU: Control Units and Accessories – Household Sys- tem Type (UL985) CSFM 7167-1615: 100, 7165-1615: 113, 7165-1615: 119, 7170-1615: 144, 7170-1615: 145 Factory Mutual Research NYC/MEA (12-92-E, Vol. 12) Installation/Configuration Notes Compatible Control Panels The D1256 Fire Keypad is compatible with the D7212, D7212B1, D7212G, D7412, D7412G, D9112, D9112B1, D9124 (using the D9112LTB, the D9112LTB-EX, or the D9412GLTB), D9412, and D9412G Control Panels. Mounting The D1256 is a low profile, surface-mounted unit molded in durable red plastic with three mounting holes in the base that allow secure, correct positioning during installation. Protect the surface-mounted D1256 by mounting it to a D56 or D56R Conduit Back Box. The D1256 can be flush mounted using a D54B or D54C Flush-mount Kit. For desktop applications, the D1256 can be mounted to a D55 Desk Stand. Note Do not install the D1256 in direct sunlight. This damages the module components and makes the display less visible. Do not mount the D1256 in wet or moist locations. Wiring The D1256 connects to the FACP through a standard four-wire cable. The field wiring connects to a four-wire harness supplied with the unit. This harness plugs into D1256 Fire Keypad ▶Provides system control with easy to use function keys ▶Built-in multi-tone sounder ▶Easy to read vacuum fluorescent display shows complete system status in English format ▶Programmable custom text for each point ▶Local system test display ▶Molded red ABS plastic construction www.boschsecurity.com 2 | D1256 Fire Keypad a four-pin connector on the circuit board through the back of the D1256. Note Use shielded cable where excessive electromagnetic interference is a problem. Technical Specifications Environmental Considerations Relative Humidity:5% to 85% non‑condensing at +86°F (+30°C) Temperature (operating):+32°F to +122°F (0°C to +50°C) Mechanical Properties Color:Red Dimensions (H x W x D):8.3 in. x 4.5 in. x 0.8 in. (21 cm x 11.4 cm x 2 cm) Material:Molded ABS plastic Power Requirements Current:104 mA minimum, 206 mA maximum Voltage:12 VDC nominal supplied by the control panel Ordering Information D1256 Fire Keypad D1256 Hardware Accessories D54B Brass Flush Mount Kit Back box and polished brass faceplate. D54B D54C Stainless Steel Flush Mount Kit Back box and stainless steel faceplate. D54C D55 Keypad Desk Stand Portable desk stand in smoke colored Plexiglas®. D55 D56 Surface Mount Conduit Box White surface mount box. D56 D56R Red Surface Mount Conduit Box Red surface mount box. D56R Americas: Bosch Security Systems 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 585 223 4060 Fax: +1 800 289 0096 security.sales@us.bosch.com www.boschsecurity.us Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: +31 40 27 83955 Fax: +31 40 27 86668 emea.securitysystems@bosch.com www.boschsecurity.com Asia-Pacific: Bosch Security Systems Pte Ltd 38C Jalan Pemimpin Singapore 577180 Phone: +65 6319 3450 Fax: +65 6319 3499 apr.securitysystems@bosch.com www.boschsecurity.com Represented by © Bosch Security Systems 2006 | Data subject to change without notice F1296821259 | Cur: en-US, V2, 24 Jan 2006 Intrusion Alarm Systems | D9127 Series POPIT Modules D9127 Series POPIT Modules www.boschsecurity.com u Provides point identification of initiating devices u Supervises wiring to devices for circuit integrity u Expands the number of points in the system u Compact size u Terminal connections for reliability The D9127 Series POPIT Modules includes the D9127T (with magnetic tamper switch) and the D9127U (without tamper). They are used with a D8125 Addressable Expansion Module when there is a need to expand a compatible control panel beyond its standard number of on-board initiating zones or points. Future system expansion is very economical as D9127 Series POPITs can be added anywhere along the two-wire data expansion loop from the D8125 module. Both modules include proven technology that combines zone and point supervision with individual device addressing on one pair of wires. Screw terminals provide reliable connections for the data expansion loop and supervised sensor loop wiring. Install a 33 kΩ end-of-line resistor at the farthest point on the loop for proper supervision. The units are small and easily installed in standard outlet boxes, above false ceilings, closets, or other accessible locations. Certifications and approvals Australia C-Tick Region Certification USA UL AMCX: Central Station Alarm Units(UL1610, UL1635), AMCX7: CentralStation Alarm Units Certified for Canada(cULus), AOTX: Local Alarm Units(UL464, UL609), AOTX7: Local AlarmUnits Certified for Canada (cULus),APAW: Police Station Alarm Units(UL365, UL464), APAW7: Police Sta-tion Alarm Units Certified for Canada(cULus), APOU: Proprietary Alarm Units(UL1076), APOU7: Proprietary AlarmUnits Certified for Canada (cULus),NBSX: Household Burglar Alarm SystemUnits (UL1023), NBSX7: HouseholdBurglar Alarm System Units Certified forCanada (cULus), UOJZ: Control Units,System (UL864, 9th edition), UTOU:Control Units and Accessories - House-hold System Type (UL985), UTOU7:Control Units and Accessories - House-hold System Type Certified for Canada(cULus) FM CSFM 7165-1615:0238 7165 -- FIRE ALARMCONTROL UNIT (COMMERCIAL) CSFM 7165-1615:0242 7165 -- FIRE ALARMCONTROL UNIT (COMMERCIAL) Region Certification CSFM 7167-1615:0239 7167 -- CONTROLUNIT (HOUSEHOLD) CSFM 7167-1615:0243 7167 -- CONTROLUNIT (HOUSEHOLD) FDNY-CoA 6059 NYC-MEA 12-92-E, Vol. 15 12-92-E, Vol. 15 NYC-MEA 12-92-E, Vol.12 12-92-E, Vol. 12 Canada ULC AMCX7.S1871 - Central Station AlarmUnits Certified for Canada ULC AOTX7.S1871 Local Alarm Units Certi-fied for Canada ULC APAW7.S1871 Police-station-connec-ted Alarm Units Certified for Canada ULC APOU7.S1871 Proprietary Alarm UnitsCertified for Canada ULC NBSX7.S1871 Household Burglar AlarmSystem Units Certified for Canada Installation/configuration notes Compatibility Information Control Panels All G Series control panels, D9412, D7412, D7212, D7212B1, D9112, D9112B1, D8112G1, D8112G2, and D9124 Module D8125 The D8125 Multiplex Zone Expander is required. The D9127 modules are wired in parallel on the D8125 data loop. Number of POPIT Modules per Control Panel D7212G, D7212GV2, D7212GV3 32 D9127 POPITs D7212B1 40 D9127 POPITs D7212, D7412, D7412G, D7412GV2, D7412GV3 67 D9127 POPITs D9124 119 D9127 POPITs D9112B1 126 D9127 POPITs D9112, D9412, D9412G, D9412GV2, D9412GV3 238 D9127 POPITs Wiring Considerations Wire Size Maximum Length of all Data Expansion Loops Combined 0.8 mm (22 AWG)549 m (1800 ft) 1.0 mm (20 AWG)881 m (2890 ft) 1.2 mm (18 AWG)1402 m (4600 ft) 1.5 mm (16 AWG)2231 m (7320 ft) 1.8 mm (14 AWG)3551 m (11650 ft) D8125 to POPIT Loops Use one two-wire data expansion loop, or distribute the POPITs on up to three loops. The maximum lengths shown in the following table are for all data expansion loops combined connected to the same D8125 module. Setting DIP switches on the POPIT modules assigns them to point numbers. The switch setting on each POPIT assigns it a point number, regardless of its physical location. POPIT to Sensor Loops The number of detection devices each sensor loop can supervise is limited only by the resistance on the loop. Resistance on each sensor loop must be less than 100 Ω not including the end-of-line (EOL) resistor. Certain UL and National Fire Protection Association (NFPA) applications can limit the number of detection devices. Consult the appropriate UL or NFPA standards. Terminate each POPIT sensor loop with the 33 kΩ EOL resistor included with each POPIT. Use a twisted-pair wire (six twists per foot) in all POPIT installations for both the data expansion loop wiring and the POPIT sensor loops. Run wires away from AC sources to prevent AC induction. Parts included Quantit y Component 1 POPIT module 1 33 kΩ EOL resistor 1 Magnet (D9127T only) 1 Hardware pack 1 Literature pack Technical specifications Environmental Considerations Relative Humidity:Up to 93% non-condensing Temperature (operating):0°C to +50°C (+32°F to +122°F) Properties Color:Off white Dimensions:8.1 cm x 3.8 cm x 2.4 cm (3.2 in. x 1.5 in. x 0.9 in.) Material:UL Listed fire-resistant Power Requirements Current Draw 0.8 mA maximum Resistance:Maximum increase in resistance on the POPIT loop is 1000 Ω. Maximum resistance between the D8125 module and each POPIT is 90 Ω. Voltage (operating):12 VDC nominal 2 | D9127 Series POPIT Modules Sensor Loop Resistance:Maximum resistance on the sensor loop is 100 Ω. Response Time:1 sec approximately Ordering information D9127T POPIT Module Includes a magnetic tamper switch. Order number D9127T D9127U POPIT Module No tamper switch. Order number D9127U 3 | D9127 Series POPIT Modules Represented by: Americas:Europe, Middle East, Africa:Asia-Pacific:China:America Latina: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 security.sales@us.bosch.com www.boschsecurity.us Bosch Security Systems B.V. P.O. Box 80002 5617 BA Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.securitysystems@bosch.com www.boschsecurity.asia Bosch (Shanghai) Security Systems Ltd. 201 Building, No. 333 Fuquan Road North IBP Changning District, Shanghai 200335 China Phone +86 21 22181111 Fax: +86 21 22182398 www.boschsecurity.com.cn Robert Bosch Ltda Security Systems Division Via Anhanguera, Km 98 CEP 13065-900 Campinas, Sao Paulo, Brazil Phone: +55 19 2103 2860 Fax: +55 19 2103 2862 latam.boschsecurity@bosch.com www.boschsecurity.com © Bosch Security Systems 2013 | Data subject to change without notice 2538178443 | en, V6, 01. Oct 2013 Fire Alarm Systems | D273 Series Photoelectric Smoke and Smoke and Heat Detectors D273 Series Photoelectric Smoke and Smoke and Heat Detectors www.boschsecurity.com u 12 VDC or 24 VDC input u Designed for commercial or residential use u Four-wire application u Light-emitting diodes (LEDs) indicate the status of the chamber, power, and alarm u Removable terminal block to simplify wiring connections The D273 Series includes the following detector models: Model Description D273 Four-wire D273IS1 Four-wire with an isolated 135°F (57°C) heat sensor and sounder D273TH Four-wire with 135°F (57°C) heat sensor D273THC Four-wire with 135°F (57°C) heat sensor and auxiliary relay D273THCS1 Four-wire with 135°F (57°C) heat sensor, auxiliary relay, and sounder D273THE Four-wire with 135°F (57°C) heat sensor and EOL relay D273THR2 Four-wire with 135°F (57°C) heat sensor and trouble relay D273THS1 Four-wire with 135°F (57°C) heat sensor and sounder D273THES1 Four-wire with 135°F (57°C) heat sensor, sounder, and EOL relay 1 Sounders produce 85 dB at 10 ft (3 m). 2 The trouble relay indicates both Dirty Smoke Chamber and/or Power Loss conditions. Each of the D273 Series Detector models is UL Listed and works with commercial fire protective signaling and household fire warning systems. Each model detects smoke particles produced during wood, paper, and fabric combustion. System Overview The D273 Series Detector models use an infrared (IR) LED light source and a silicon photodiode to measure light in a chamber. A fine screen covers the chamber to deter insects and reduce dust accumulation and nuisance alarms. During a fire, smoke particles reflect light onto the photodiode. When the photodiode measurements exceed the alarm threshold, the detector signals an alarm condition. After the alarm condition clears, interrupt power at the control panel to reset the detector. When a D132B Reversing Relay Module is used, the LED does not latch on alarm. Functions Chamber Calibration Tests Check the sensitivity and calibration of any D273 Series Detector model using a visual check, a magnet test, or a voltage measurement test. Refer to the D263/D273 Series Installation Guide (P/N: 31341) for specific instructions to perform these sensitivity tests. Certifications and Approvals Region Certification USA UL UROX: Smoke - Automatic Fire Detectors(UL268 and A), UROX7: Smoke - Auto-matic Fire Detectors Certified for Cana-da (cULus) Hong Kong HKFSD D273IS, D273THC, D273THCS,D273THE, D273THES, D273R, andD273S only USA MSFM NYC-MEA 274-93-E, Vol. VII CSFM 7272-1615:0134 Installation/Configuration Notes Use smoke detectors for detection circuits that protect people. Use heat detectors for circuits that protect property. Compatible Products The following products are compatible with the D273 Series detectors: Category Product ID Product Description Control Panels The D273 Series Detector models are compatible with UL Listed four-wire control panels. Refer to the manufacturer’s installation instructions to select the correct EOL resistor. Modules D132B Reversing relay module Loop Supervision For loop supervision, install a Bosch Security Systems D275 Power Supervision Module and an EOL resistor after the last device on the loop. Mounting The detector has a mounting plate that attaches to a standard four-inch back box. For commercial and industrial installations in accordance with NFPA 72, space each detector 30 ft (9.2 m) apart. Wiring The terminal block accepts up to 12 AWG (2.3 mm) wire. You can remove the terminal block from the detector for easier wiring. The terminal block snaps in and out of the detector. Parts Included Quant.Component 1 Detector 1 Literature pack Technical Specifications Environmental Considerations Relative Humidity:Up to 93%, non-condensing Operating and Storage Temperature: +32°F to +120°F (0°C to +40°C) Radio Frequency Interference (RFI) Immunity No alarm or setup on critical frequencies in the range of 26 MHz to 950 MHz. Mechanical Properties Dimensions (Diameter x H):5 in. x 2 in. (12.7 cm x 5.1 cm) Material:High impact, fire retardant ABS plastic Power Requirements Power-up Time:22 sec maximum RMS Ripple:25% of DC input maximum Voltage (stand-by):10 VDC to 30 VDC Current Draw (alarm) at 30 VDC D273, D273TH:18 mA maximum D273THC: 33 mA maximum D273THE, D273THR: 36 mA maximum D273THS: 78 mA maximum D273THCS: 90 mA maximum D273THES:96 mA maximum D273IS: 100 mA maximum Current Draw (standby) D273, D273TH, D27THC, D273THCS, D273THS: 0.1 mA maximum D273IS:0.14 mA maximum D273THE, D273THES:15 mA D273THR:18 mA maximum Ordering Information D273 Four‑Wire Smoke Detector Four‑wire smoke detector. Order number D273 2 | D273 Series Photoelectric Smoke and Smoke and Heat Detectors D273IS Four‑Wire Smoke Detector with Isolated Heat Sensor and Sounder Four‑wire smoke detector with an isolated 135°F (57°C) heat sensor and a sounder. Order number D273IS D273TH Four‑Wire Smoke/Heat Detector Four‑wire smoke detector with a 135°F (57°C) heat sensor. Order number D273TH D273THC Four‑Wire Smoke/Heat Detector with Auxili- ary Relay Four‑wire smoke detector with an isolated 135°F (57°C) heat sensor and an auxiliary relay. Order number D273THC D273THCS Four‑Wire Smoke/Heat Detector with Auxili- ary Relay and Sounder Four‑wire smoke detector with a 135°F (57°C) heat sensor, an auxiliary relay, and a sounder. Order number D273THCS D273THE Four‑Wire Smoke/Heat Detector with EOL Re- lay Four‑wire smoke detector with a 135°F (57°C) heat detector and an EOL relay. Order number D273THE D273THES Four‑Wire Smoke/Heat Detector with EOL Relay and Sounder Four‑wire smoke detector with a 135°F (57°C) heat sensor, a sounder, and an EOL relay. Order number D273THES D273THR Four‑Wire Smoke/Heat Detector with Trouble Relay Four‑wire smoke detector with a 135°F (57°C) heat sensor and a trouble relay. Order number D273THR D273THS Four‑Wire Smoke/Heat Detector with Sounder Four‑wire smoke detector with a 135°F (57°C) heat sensor and a sounder. Order number D273THS Accessories D275 Power Supervision Module Line supervision device for four-wire fire detection circuits Order number D275 D1005 Test Cable Connects a digital voltmeter to the detector's calibration pin for verifying that the detector is within its calibration range Order number D1005 DT‑2 Detector Removal Tool Use the DT‑2 to remove, replace, or test the detector head Order number DT-2 TP280 Trim Plate For retrofit and remodeling purposes; 16.2 cm (6 in.) diameter Order number TP280 3 | D273 Series Photoelectric Smoke and Smoke and Heat Detectors 4 | D273 Series Photoelectric Smoke and Smoke and Heat Detectors Represented by: Americas:Europe, Middle East, Africa:Asia-Pacific:China:America Latina: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 security.sales@us.bosch.com www.boschsecurity.us Bosch Security Systems B.V. P.O. Box 80002 5617 BA Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.securitysystems@bosch.com www.boschsecurity.asia Bosch (Shanghai) Security Systems Ltd. 201 Building, No. 333 Fuquan Road North IBP Changning District, Shanghai 200335 China Phone +86 21 22181111 Fax: +86 21 22182398 www.boschsecurity.com.cn Robert Bosch Ltda Security Systems Division Via Anhanguera, Km 98 CEP 13065-900 Campinas, Sao Paulo, Brazil Phone: +55 19 2103 2860 Fax: +55 19 2103 2862 al.securitysystems@bosch.com www.boschsecurity.com © Bosch Security Systems 2012 | Data subject to change without notice 2700558987 | en, V3, 14. Aug 2012 Fire Alarm Systems | D1257 Fire Annunciator The D1257 Fire Annunciator is typically installed in building entrances and areas with unrestricted access. This allows a responding agency or persons evacuating the building to quickly and safely identify the type and location of the emergency from outside the building. It has a built-in sounder that allows it to be installed out of sight. Audible tones alert personnel to fire system events and assist fire fighters in locating the annunciator. The D1257 can be placed in public locations because it lacks function keys. Two navigational keys allow the user to step forward or backward through a list of system events. Certifications and Approvals Listings and UL AMCX: Central Station Alarm Units (UL1610) Approvals: UL APAW: Police Station Alarm Units (UL365) UL APOU: Proprietary Alarm Units (UL1076) UL NBSX: Household Burglary Alarm System Units (UL1023) UL UOXX: Control Unit Accessories, System (UL864) UL UTOU: Control Units and Accessories – Household Sys- tem Type (UL985) CSFM 7167-1615: 100, 7165-1615: 113, 7165-1615: 119, 7170-1615: 144, 7170-1615: 145 Factory Mutual Research NYC/MEA (12-92-E, Vol. 12) Installation/Configuration Notes Compatible Control Panels The D1257 Fire Annunciator is compatible with the D7212, D7212B1, D7212G, D7412, D7412G, D9112, D9112B1, D9124, D9412 (using the D9112LTB, the D9112LTB-EX, or the D9412GLTB), and D9412G Control Panels. Mounting The D1257 is a low profile, surface-mounted unit molded in durable red plastic with three mounting holes in the base that allow secure, correct positioning during installation. Protect the surface-mounted D1257 by mounting it to a D56 or D56R Conduit Back Box. The D1257 can be flush mounted using a D54B or D54C Flush-mount Kit. For desktop applications, the D1257 can be mounted to a D55 Desk Stand. Note Do not install the D1257 in direct sunlight. This damages the module components and makes the display less visible. Do not mount the D1257 in wet or moist locations. D1257 Fire Annunciator ▶Can be remotely installed in public access areas ▶Built-in multi-tone sounder ▶Easy to read vacuum fluorescent display shows complete system status in English format ▶Programmable custom text for each point ▶Local system test display ▶Molded red ABS plastic construction www.boschsecurity.com 2 | D1257 Fire Annunciator Wiring The D1257 connects to the FACP through a standard four-wire cable. The field wiring connects to a four-wire harness supplied with the unit. This harness plugs into a four-pin connector on the circuit board through the back of the D1257. Note Use shielded cable where excessive electromagnetic interference is a problem. Technical Specifications Environmental Considerations Relative Humidity:5% to 85% non‑condensing at +86°F (+30°C) Temperature (operating):+32°F to +122°F (0°C to +50°C) Mechanical Properties Color:Red Dimensions (H x W x D):8.3 in. x 4.5 in. x 0.8 in. (21 cm x 11.4 cm x 2 cm) Material:Molded ABS plastic Power Requirements Current: 104 mA minimum, 206 mA maximum Voltage:12 VDC nominal supplied by the control panel Ordering Information D1257 Fire Annunciator D1257 Hardware Accessories D54B Brass Flush Mount Kit Back box and polished brass faceplate. D54B D54C Stainless Steel Flush Mount Kit Back box and stainless steel faceplate. D54C D55 Keypad Desk Stand Portable desk stand in smoke colored Plexiglas®. D55 D56 Surface Mount Conduit Box White surface mount box. D56 D56R Red Surface Mount Conduit Box Red surface mount box. D56R Americas: Bosch Security Systems 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 585 223 4060 Fax: +1 800 289 0096 security.sales@us.bosch.com www.boschsecurity.us Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: +31 40 27 83955 Fax: +31 40 27 86668 emea.securitysystems@bosch.com www.boschsecurity.com Asia-Pacific: Bosch Security Systems Pte Ltd 38C Jalan Pemimpin Singapore 577180 Phone: +65 6319 3450 Fax: +65 6319 3499 apr.securitysystems@bosch.com www.boschsecurity.com Represented by © Bosch Security Systems 2006 | Data subject to change without notice F1295896075 | Cur: en-US, V2, 24 Jan 2006 • Two (2) Class A or two (2) Class B FACP inputs. • Two (2) NC dry contact trigger inputs (AL802ULADA and AL1002ULADA only) • Two (2) Class A or four (4) Class B indicating circuits. • Two (2) Class B outputs may be paralleled for more power on an indicating circuit. • One (1) Aux. Power Output @ 1 amp supply current (w/battery back up). • Signal Circuit Trouble Memory - facilitates quickly locating intermittent system trouble and eliminates costly and unnecessary service calls. LED’s indicate a prior fault (short, open, ground) has occurred on one or more signaling circuit outputs. • 2-wire Horn/Strobe Sync mode allows audible notification appliances (Horns) to be silenced while visual notification appliances (Strobes) continue to operate. • Horn/Strobe sync protocols include: Gentex®, System Sensor®, Faraday, Amseco. • Temporal Code 3 Mode. • Steady Mode. • Input to Output Follower Mode (maintains synchronization of notification appliance circuits). • March Time. • Compatible with 24VDC or 12VDC fire panels. • Common trouble inputs and outputs. • Ground fault detection. • Input 115VAC. • AC fail supervision (form "C" contacts). • Low battery supervision (form "C" contacts). • Battery presence supervision (form “C” contacts). • Power supply, logic board, red enclosure, cam lock, transformer & battery leads. • Enclosure: - Combination knockouts re 1/2” and 3/4” - Accommodates up to two (2) 12VDC/12AH batteries. AL602ULADA, AL802ULADA, AL1002ULADA NAC Power Extenders Rev. AL602/802/1002ULADA- L20E Overview Specifications Agency Approvals AL602ULADA • 24VDC or 12VDC rated @ 6.5 amp max. • Two (2) Class A or four (4) Class B outputs. AL602ULADAJ • Larger enclosure. AL802ULADA • 24VDC or 12VDC rated @ 8 amp max. • Two (2) Class A or four (4) Class B outputs. AL802ULADAJ • Larger enclosure. AL1002ULADA • 24VDC rated @ 10 amp max. • Two (2) Class A or four (4) Class B outputs. AL1002ULADAJ • Larger enclosure. UL Listed Control Units and Accessories for Fire Alarm Systems (UL 864), UL Listed Standard for Safety for Fire Protective Signaling Systems (UL 1481). Factory Mutual Approved.NYC Department of Buildings Approved. California State Fire Marshal Approved. • The AL602ULADA, AL802ULADA and AL1002ULADA are extremely cost effective voltage regulated remote NAC Power Extenders. They may be connected to any 12 or 24 volt Fire Alarm Control Panel (FACP). Primary applications include Notification Appliance Circuit (NAC) expansion (supports ADA requirements) and will provide auxiliary power to support system accessories. Altronix Corp. - 140 58th Street, Brooklyn, NY 11220 • 718-567-8181 • 888-258-7669 • altronix.com Enclosure Dimensions AL602ULADA, AL802ULADA and AL1002ULADA: 15.5"H x 12"W x 4.5"D .875" 1" 1.3"9.97" 13.53" 6.625" 2.25"3.68"4.56" 1.22" 1.22" 3.5" 1" 13.25" 2" 1.22" 12" 15.5" 4.5" 2.25"3.68"4.56" 1.22" 1.25" 2.2" 1" 18"18" 14.5" 14.5" 4.5" 4.5" 4.5" 4.5" 4.5" 18" 1.25" 1.5"4.0"6.5"1.5"1.25" 1.5" 4.0" 10.0" 1.25" 2.75"7.25" 1.0" 1.5" 1.0" 1.0" 1.0" 1.25" 2.75" 1.5" 10" AL602ULADAJ, AL802ULADAJ and AL1002ULADAJ: 18"H x 14.5"W x 4.625"D Fire Alarm Systems | FMM‑100 Series Die‑cast Metal Fire Alarm Manual Stations The FMM‑100 Series is a family of versatile, high‑quality, metal fire alarm manual stations. Single‑action or dual‑action models are available. All models come with a key lock and contain gold‑plated contacts to resist corrosion. Functions Operation Single-action When the bar on the front of the manual station is pulled, it latches open and is easily visible from 50 ft (15 m). Reset the activation bar by opening the manual station with the key and placing the activation bar in its normal upright position. An optional scored acrylic break rod is available. Dual-action With the dual‑action configuration the upper bar on the front of the manual station rotates inward allowing the activation bar to be grasped and operated by a single hand. Certifications and Approvals Region Certification USA UL UNIU: Boxes, Non-Coded (UL38), UNIU7: Boxes, Non-Coded Certified for Canada (cULus) CSFM 7150-1615: 224 NYC-MEA 382-94-E or 382-94-E, Vol. 3 Installation/Configuration Notes Compatibility Information Compatible with all Bosch Security Systems, Inc. Fire Alarm Control Panels. Mounting Considerations The FMM Series manual stations can be surface mounted on either the FMM‑100BB‑R Surface‑mount Back Box or the FMM‑100WPBB‑R Weatherproof Back Box. They can also be flush mounted on a standard single‑gang back box. Note When properly mounted on the FMM‑100WPBB‑R Weatherproof Back Box, these manual stations meet UL requirements for outdoor use. FMM‑100 Series Die‑cast Metal Fire Alarm Manual Stations ▶Single or dual action ▶Terminal connections ▶Gold‑plated alarm contacts for corrosion resistance ▶Surface or weatherproof back boxes www.boschsecurity.com 2 | FMM‑100 Series Die‑cast Metal Fire Alarm Manual Stations To comply with ADA standards, the manual station must be less than 48 in. (1.2 m) above the floor for front wheelchair access and less than 54 in. (1.3 m) above the floor for side wheelchair access. Parts Included Quant. Component 1 Manual station 1 D102 Key (1358 key) 1 FMM‑100GR Acrylic Break Rod 1 Hardware pack 1 Literature pack Technical Specifications Environmental Considerations Relative Humidity: 90% at +100°F (+38°C) Temperature (operating): -40°F to +150°F (-40°C to +66°C) Mechanical Properties Color:Red Dimensions (H x W x D): 4.75 in. x 3.25 in. x 1.1 in. (12 cm x 8.3 cm x 2.8 cm) Material:die‑cast metal Inputs Switch Rating: 1 A at 30 VDC or 125 VAC Ordering Information FMM‑100SATK Single‑action Manual Station (red) Versatile, high‑quality, metal single‑action fire alarm manual station with key lock and gold‑plated contacts FMM-100SATK FMM‑100SATK‑NYC Single‑action Manual Station for New York City Versatile, high‑quality, metal single‑action fire alarm manual station for New York City with key lock and gold‑plated contacts FMM-100SATK-NYC FMM‑100DATK Dual‑action Manual Station (red) Versatile, high‑quality, metal dual‑action fire alarm manual station with key lock and gold‑plated contacts FMM-100DATK Accessories D102 Replacement Key Replacement key (#1358) for the D101 lock. D102 FMM‑100BB‑R Surface‑mount Back Box (red) Red cast‑metal back box FMM-100BB-R FMM‑100WPBB‑R Weatherproof Back Box (red) Red cast‑metal weatherproof back box FMM-100WPBB-R FMM‑100GR Scored Acrylic Break Rods Scored acrylic rods (12 per package) FMM-100GR Americas: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 security.sales@us.bosch.com www.boschsecurity.us Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com Asia-Pacific: Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6258 5511 Fax: +65 6571 2698 apr.securitysystems@bosch.com www.boschsecurity.com Represented by © Bosch Security Systems Inc. 2010 | Data subject to change without notice T2363731851 | Cur: en-US, V8, 4 Jul 2010 Agency Listings Features • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Field-selectable candela settings on ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and three volume selections • Universal mounting plate for ceiling units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert devices • Compatible with MDL sync module • Listed for ceiling or wall mounting The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections. Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications SpectrAlert® Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. MEA452-05-E3023572 7125-1653:186 (indoor strobes) 7125-1653:188 (horn strobes, chime strobes) 7135-1653:189 (horns, chimes) S4011 (chimes, horn strobes, horns) S5512 (strobes) AVDS00501 SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance strobes and horn strobes shall mount to a standard 4 × 4 × 1½-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 × 4 × 17⁄8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411 ⁄16 × 411 ⁄16 × 21 ⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens)6.8˝ diameter × 2.5˝ high (173 mm diameter × 64 mm high) Ceiling-Mount Back Box Skirt Dimensions (BBSC-2, BBSCW-2)7.1˝ diameter × 2.2˝ high (180 mm diameter × 57 mm high) Ceiling-Mount Trim Ring Dimensions (sold as a 5 pack) (TRC-HS, TRCW-HS) 6.9˝ diameter × 0.35˝ high (175 mm diameter × 9 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS00501 Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts 24-Volt Nominal Reverberant Anechoic DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7†Coded High 82 82 88 88 93 92 101 101 8†Coded Medium 78 78 85 85 90 90 97 98 9†Coded Low 75 75 81 81 88 85 96 92 †Settings 7, 8, and 9 are not available on 2-wire horn strobes. UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High Candela Range 135 NA NA 228 207 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Standard Candela Range (15–115 cd) DC Input 8–17.5 Volts 16–33 Volts 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, High Candela Range (135–185 cd) DC Input 16–33 Volts FWR Input 16–33 Volts 135 150 177 185 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 UL Current Draw Data Horn Strobe Tones and Sound Output Data 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2012 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS00501 • 3/12 SpectrAlert Advance Dimensions Model Description Ceiling Horn Strobes PC2R*2-Wire Horn Strobe, Standard cd, Red PC2RH 2-Wire Horn Strobe, High cd, Red PC2W*†2-Wire Horn Strobe, Standard cd, White PC2WH*2-Wire Horn Strobe, High cd, White PC4R 4-Wire Horn Strobe, Standard cd, Red PC4RH 4-Wire Horn Strobe, High cd, Red PC4W 4-Wire Horn Strobe, Standard cd, White SpectrAlert Advance Ordering Information Notes: * Add “-P” to model number for plain housing (no “FIRE” marking on cover), e.g., P2R-P. † Add “-SP” to model number for “FUEGO” marking on cover, e.g., P2R-SP. ‡ “Standard cd” refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. “High cd” refers to strobes that include 135, 150, 177, and 185 candela settings. 4.7˝ 5.6˝ 6.8˝ Dia. 2.5˝ 2.5˝2.23˝5.05˝ 5.98˝ 7.1˝ Dia. 2.25˝ 5.1˝ 2.0˝ 5.7˝ 7.1˝ Dia. 2.0˝ Ceiling-mount horn strobes Ceiling back box skirt Model Description Ceiling Strobes SCR Strobe, Standard cd, Red SCRH Strobe, High cd, Red SCW*Strobe, Standard cd, White SCWH Strobe, High cd, White Accessories BBSC-2 Back Box Skirt, Ceiling, Red Back Box Skirt, Ceiling, White TRC-HS Trim Ring, Ceiling, Red TRCW- HS Trim Ring, Ceiling, White Agency Listings Features • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Field-selectable candela settings on ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and three volume selections • Universal mounting plate for ceiling units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert devices • Compatible with MDL sync module • Listed for ceiling or wall mounting The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections. Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications SpectrAlert® Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. MEA452-05-E3023572 7125-1653:186 (indoor strobes) 7125-1653:188 (horn strobes, chime strobes) 7135-1653:189 (horns, chimes) S4011 (chimes, horn strobes, horns) S5512 (strobes) AVDS00501 SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance strobes and horn strobes shall mount to a standard 4 × 4 × 1½-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 × 4 × 17⁄8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411 ⁄16 × 411 ⁄16 × 21 ⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens)6.8˝ diameter × 2.5˝ high (173 mm diameter × 64 mm high) Ceiling-Mount Back Box Skirt Dimensions (BBSC-2, BBSCW-2)7.1˝ diameter × 2.2˝ high (180 mm diameter × 57 mm high) Ceiling-Mount Trim Ring Dimensions (sold as a 5 pack) (TRC-HS, TRCW-HS) 6.9˝ diameter × 0.35˝ high (175 mm diameter × 9 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS00501 Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts 24-Volt Nominal Reverberant Anechoic DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7†Coded High 82 82 88 88 93 92 101 101 8†Coded Medium 78 78 85 85 90 90 97 98 9†Coded Low 75 75 81 81 88 85 96 92 †Settings 7, 8, and 9 are not available on 2-wire horn strobes. UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High Candela Range 135 NA NA 228 207 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Standard Candela Range (15–115 cd) DC Input 8–17.5 Volts 16–33 Volts 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, High Candela Range (135–185 cd) DC Input 16–33 Volts FWR Input 16–33 Volts 135 150 177 185 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 UL Current Draw Data Horn Strobe Tones and Sound Output Data 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2012 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS00501 • 3/12 SpectrAlert Advance Dimensions Model Description Ceiling Horn Strobes PC2R*2-Wire Horn Strobe, Standard cd, Red PC2RH 2-Wire Horn Strobe, High cd, Red PC2W*†2-Wire Horn Strobe, Standard cd, White PC2WH*2-Wire Horn Strobe, High cd, White PC4R 4-Wire Horn Strobe, Standard cd, Red PC4RH 4-Wire Horn Strobe, High cd, Red PC4W 4-Wire Horn Strobe, Standard cd, White SpectrAlert Advance Ordering Information Notes: * Add “-P” to model number for plain housing (no “FIRE” marking on cover), e.g., P2R-P. † Add “-SP” to model number for “FUEGO” marking on cover, e.g., P2R-SP. ‡ “Standard cd” refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. “High cd” refers to strobes that include 135, 150, 177, and 185 candela settings. 4.7˝ 5.6˝ 6.8˝ Dia. 2.5˝ 2.5˝2.23˝5.05˝ 5.98˝ 7.1˝ Dia. 2.25˝ 5.1˝ 2.0˝ 5.7˝ 7.1˝ Dia. 2.0˝ Ceiling-mount horn strobes Ceiling back box skirt Model Description Ceiling Strobes SCR Strobe, Standard cd, Red SCRH Strobe, High cd, Red SCW*Strobe, Standard cd, White SCWH Strobe, High cd, White Accessories BBSC-2 Back Box Skirt, Ceiling, Red Back Box Skirt, Ceiling, White TRC-HS Trim Ring, Ceiling, Red TRCW- HS Trim Ring, Ceiling, White Agency Listings Features • Weatherproof per NEMA 4X, IP56 • Listed to UL 1638 (strobe) and UL 464 (horn) • Compatible with System Sensor synchronization protocol and legacy SpectrAlert products • Field-selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Rotary switch for horn tone and three volume selections • Horn rated at 88+ dBA at 16 volts • Rated from –40°F to 151°F • Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Listed for ceiling or wall mounting SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from −40°F to 151°F. Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field-selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in-and- out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock-outs located on the back eliminate the need to drill holes for screw-in mounting. Plastic and metal weatherproof back boxes come with ¾-inch top and bottom conduit entries and ¾-inch knock-outs at the back. A screw-in NPT plug with an O-ring gasket for a watertight seal is included with each back box. Outdoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert® Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. MEA452-05-E3023572 7300-1653:187 (outdoor strobes) 7125-1653:188 (horn strobes, chime strobes) 7135-1653:189 (horns, chimes) S4011 (chimes, horn strobes, horns) S3593 (outdoor and alert strobes) AVDS01201 SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between −40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non-coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature –40°F to 151°F (–40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens)5.6˝ L × 4.7˝ W × 2.5˝ D (142 mm L × 119 mm W × 64 mm D) Horn Dimensions 5.6˝ L × 4.7˝ W × 1.3˝ D (142 mm L × 119 mm W × 33 mm D) Wall-Mount Weatherproof Back Box Dimensions (SA-WBB)5.7˝ L × 5.1˝ W × 2.0˝ D (145 mm L × 130 mm W × 51 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201 Horn and Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts 24-Volt Nominal Reverberant Anechoic DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- Temporal High 82 82 88 88 93 92 100 100 5 Non- Temporal Medium 78 78 85 85 90 90 98 98 6 Non- Temporal Low 75 75 81 81 88 84 96 92 7†Coded High 82 82 88 88 93 92 101 101 8†Coded Medium 78 78 85 85 90 90 97 98 9†Coded Low 75 75 81 81 88 85 96 92 †Settings 7, 8, and 9 are not available on 2-wire horn strobe. UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High Candela Range 135 NA NA 228 207 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Standard Candela Range (15–115 cd) DC Input 8–17.5 Volts 16–33 Volts 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, High Candela Range (135–185 cd) DC Input 16–33 Volts FWR Input 16–33 Volts 135 150 177 185 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 UL Max. Horn Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-Temporal High 57 56 69 75 Non-Temporal Medium 42 50 60 69 Non-Temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 UL Current Draw Data Horn Tones and Sound Output DataCandela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Strobe Output (cd) Listed Candela Candela rating at –40°F 15 Do not use below 32°F15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2012 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS01201 • 3/12 SpectrAlert Advance Diagrams Model Description Wall Horn Strobes P2RK*†2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P2RHK*†2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) P2WK*†2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK*†2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RK†4-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V (includes plastic weatherproof back box) Wall Strobes SRK*†Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHK*†Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SWK*†Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK*†Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HRK†Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box SpectrAlert Advance Ordering Information Notes: * Add “-P” to model number for plain housing (no “FIRE” marking on cover), e.g., P2RK-P. † Add “-R” to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate, WTP and WTPW. “Standard cd” refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. “High cd” refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. 4.7˝ 5.6˝ 6.8˝ Dia. 2.5˝ 2.5˝ Wall-Mount Horn Strobes Wall Plastic Weatherproof Back Box Wall-Mount Horn Strobe with Plastic Weatherproof Back Box Features • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Listed for ceiling mounting only The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Agency Listings 7125-1653:0504 7135-1653:0503 S5512 S4011 FM approved except for ALERT models 3057383 AVDS868-02 • 12/01/2017 • Page 3 AVDS868-02 • 12/01/2017 • Page 2 L-Series Specifications Architect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 × 4 × 1½-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 × 4 × 17⁄8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11 ⁄16 × 4 11 ⁄16 × 2 1 ⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3)8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens)6.8" diameter × 2.5" high (173 mm diameter × 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions (SBBCRL, SBBCWL) 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS868-02 • 12/01/2017 • Page 3 Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 UL Current Draw Data Horn Strobe Tones and Sound Output Data UL Max. Horn Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC DC FWR Candela Range 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 UL Max. Current Draw (mA RMS), Ceiling Horn Strobe, Candela Range (15–177 cd) DC Input 8–17.5 Volts 16–33 Volts 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1K Temporal High 111 164 69 94 147 163 184 229 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 FWR Input 16–33 Volts 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2017 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS868-02 • 12/01/2017 L-Series Dimensions Model Description Ceiling Horn Strobes PC2RL 2-Wire, Horn Strobe, Red PC2WL 2-Wire, Horn Strobe, White PC4RL 4-Wire, Horn Strobe, Red PC4WL 4-Wire, Horn Strobe, White L-Series Ordering Information Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box Model Description Ceiling Strobes SCRL Strobe, Red SCWL Strobe, White SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White 6.83" diam. (173 mm) 2.47" (62.7 mm) 1.37" (34.8 mm)6.92" diam. (175.77 mm) 2.5" (64 mm) 2-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box A0531-01 A0545-00 A0546-00 A0494-01 For a ceiling-listed horn-only device, see AVDS865 “Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications”. 87-7810, 800-327-2443, Fox: 908-687-8860 www.paigeelectric.com 74183PRWH 1 3 PAIRS 18 AWG STRANDED W24120 x �l 1.0 SCOPE: 2.3 ASSEMBLY: 1.1 18 AWG, 3 pair unshielded cable 2.3.1 Lay Length: constructed with stranded bare copper Pairs: 1.75" - 2.0" LHL nom. conductors, polypropylene insulation, and Cable: 4.5" LHL nom, an overall white PVC jacket for data communications / security applications. 2.4 .JACKET: Manufactured in the USA. 2.4.1 Material: PVC Type FPL 2.4.2 Wall Thickness: .020" UL Standard 1424 2.43 OD:.264" nom. NEC Article 760 2.4.4 Color: White UL 1581 2.4.5 RIPCORD UNDER JACKET CSFM 2.4.6 Markings: Paige 74183PRWH 18/3PR E191596 C(UL) FPL "RoHS COMPLIANT" 2.0 CONSTRUCTION: DESCENDING FOOTAGE MARKINGS 2,1 CONDUCTOR: EVERY TWO FEET 2.1.1 Material: Bare Copper 2.1.2 Size: 18 AWG 2.5 ELECTRICAL PROPERTIES 2.1,3 Construction: 7 Strand 2.5.1 Temperature: -20°C to 75°C 2.5.2 Voltage: 300 Volt 2.2 INSULATION: 2.5.3 Capacitance: 20 pF/Ft nom. 2.2.1 Material: Polypropylene 2.5.4 Impedance: 81 Ohms 2,2.2 Wall Thickness: .006" nom. 2.5.5 DC Resistance: 6.3 Ohms/M' @ 20°C 2.2.3 O.D.:.058" nom. 2.2.4 Color code: 2.6 PUT -UPS Pair 1: Black, Red 2.6.1 1000' 1 Pac 3 Box 99HO02G Pair 2: Yellow, Green 2.6.2 Weight: 41 lbs / 1000' Pair 3: Brown, Blue The information and specilrcations desufbed herein ore suNecl to error or omission and to change vAthout notice- Poige provides the information and specifications herein on an "AS IS" basfs, wth no representations or vierrantles, whether express, statutory or implied. fn no event vAll Poige be Iiioble for any damages ['including consequenfial, Indirect, incidental, speclaf punitive, or oxemplary damages] whaisoever, even if Paige hos been advised of the possibility of such damages, whether In an action under contract, neg�gence or any other theory, arising oul of or in connection vAth the use, or Inabllity to use, the Information or specd1collons described herein. G-WW41WRWH Rev 1.6 10/14/10-0 The information and specifications described herein are subject to error or omission and to change without notice. Paige provides the information and specifications herein on an “AS IS” basis, with no representations or warranties, whether express, statutory or implied. In no event will Paige be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Paige has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. G-WM74122ZWH Rev 1.7 10/25/10-Q 74122ZWH spec 2 CONDUCTOR 12 AWG STRANDED TYPE CL3/FPL PARALLEL / ZIP 1.0 SCOPE: 1.1 12 AWG, 2 conductor cable constructed with stranded bare copper in a parallel / zip construction with one leg red striped for polarity; for data communications / security applications manufactured in the USA and (UL) listed CL3/FPL UL Standards 13 &1424 NEC Articles 725 & 760 UL 1581 CSFM 2.0 CONSTRUCTION: 2.1 CONDUCTOR: 2.1.1 Material: Stranded Bare Copper 2.1.2 Size: 12 AWG 2.1.3 Construction: 7 Strand 2.2 ASSEMBLY: 2.2.1 Lay Length: Parallel 2.3 INSULATION: 2.3.1 Material: PVC 2.3.2 Wall Thickness: .030” nom. 2.3.3 OD: .150” x .320” nom. 2.3.4 Color: White, with one leg red striped for polarity 2.3.5 Markings: PAIGE 74122ZWH E191596 12/2C PARALLEL/ZIP C(UL) CL3/FPL OR CMG “RoHS COMPLIANT” DESCENDING FOOTAGE MARKINGS EVERY TWO FEET 2.4 ELECTRICAL PROPERTIES 2.4.1 Temperature: -20˚C to 75˚C 2.4.2 Voltage: 300 Volt 2.4.3 Impedance: 100 Ohms 2.4.4 DC Resistance: 1.6 Ohms/M’ @ 20˚C 2.5 PUT-UPS: 2.5.1 1000’ 1 Pac 2 Box 99H003HG 2.5.2 Weight: 56 lbs / 1000’ 908-687-7810, 800-327-2443, Fax: 908-687-8860 www.paigeelectric.com UL LLC CERTIFICATE OF COMPLIANCE COVER PAGE Applicant Subscriber No: 974889-001 Service Center Number: 7 Listed Service From: BOYNTON BEACH, FL WAL-MART STORES INC ALARM CENTRAL STORE STORE #5911 3625 S FEDERAL HWY BOYNTON BEACH FL 33435-8656 WAL-MART STORES INC ALARM CENTRAL STORE STORE #5911 3625 S FEDERAL HWY BOYNTON BEACH FL 33435-8656 08-JAN-2021 Alarm Service Company:Service Center: UUJS S25122 1 ACTIVE LISTINGS CCN File No. Vol. No. THIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate. CERTIFICATE OF COMPLIANCE WAL-MART STORES INC ALARM CENTRAL STORE STORE #5911 3625 S FEDERAL HWY BOYNTON BEACH FL 33435-8656 WAL-MART STORES INC ALARM CENTRAL STORE STORE #5911 3625 S FEDERAL HWY BOYNTON BEACH FL 33435-8656 The Alarm Service Company is Listed in the following Certificate Service Categories: File - Vol No. CCN Listing Category S25122 - 1 ***THIS CERTIFICATE EXPIRES ON 31-MAR-2022 *** "LOOK FOR THE UL ALARM SYSTEM CERTIFICATE" UUJS [Signal and Fire Alarm Equipment and Services] (Protective Signaling Services) Local, Auxiliary, Remote Station and Proprietary BOYNTON BEACH, FL Alarm Service Company: (100574-907)Service Center: (100574-907) Listed Service From: Applicant ID No: Service Center No: Expires: 974889-001 7 31-MAR-2022