Loading...
20395_Electrical Compliance forms 081721 (2)E:7lNPOVAI https://waenergycodes.com/print_project_Summary_form.php?k=aWQgNDgl NCZmdmk9MTgmY3RpPQ==&print=1 LIGHTING COMPLIANCE SUMMARY 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all Rl Administered by: ©2021 NEEA, All rights reserved Project & Applicant Information Project Title Harbor Freight Tools - 2018 WSEC For Building Department Use: I Date' Aug 12, 2021 Project Address 906 East Yelm Avenue Yelm, WA 98597 Applicant Name John Watson Applicant Phone 216-521-5134 Applicant Email jwatson@adaarchitects.cc For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Luminaire Replacement Scope Retail, General Sales Building Cond. Floor Area 13,643 General Project Types Alteration New Building or Addition Li hfin Sco a g g p Space by space No Calculation Adjustments allowed COMPLIES Alteration Lighting Scope Interior Lighting Project Cond. Floor Area 13,643 Floors Above Grade 1 Compliance Method Compliance Method 1 - General Lighting Project Description Removal of all existing interior lighting, installing new LED lighting system and energy management system. Lighting Compliance Scope Project Type Interior / Exterior (Interior includes both interior & parking) Luminaire Replacement Scope LPA Calculation Compliance Method Adjustment Compliance Verification and Method Alteration Interior Lighting 50% or more replaced Space by space No Calculation Adjustments allowed COMPLIES Additional Efficiency Corridors General Options Included 0.41 49 ProjecrTTRq Harbor Freight Tools - 2018 WSEC Date I Aug 12,20 1 Lighting Power Calculation ALTERATION - INTERIOR LIGHTING (50% or more replaced) Compliance Verification COMPLIES Compliance Method Space by space LPA Calculation Adjustment I none hftps://waenergycodes.com/print_project_summary_form.php?k=aWQ9NDgl NCZmdmk9MTgmY3RpPQ==&print=1 1/2 Interior Lighting Power Allowance - Space by Space Proposed Lighting Power Density General Space Type Specific Space Type Ceiling Gross Interior Area (SF) Height (Ft) LPA (Watts/SF) Total Watts Allowed (SF x LPA x 1) Total Proposed Watts Compliance Status (LPD + Display LPD) Corridors General 119 0.41 49 Lounge/breakroom General 152 0.59 90 236 Office Enclosed less than 250 sf 119 0.74 88 252 Office Enclosed less than 250 sf 138 0.74 102 350 Restroom General 129 0.63 81 800 Retail General sales 8,256 1.05 8,669 7,600 Warehouse/storage area Medium to bulky palletized items 4,730 0.33 1,561 1,400 Proposed Total LPD 10638 Totals 10,640 10,638 COMPLIES hftps://waenergycodes.com/print_project_summary_form.php?k=aWQ9NDgl NCZmdmk9MTgmY3RpPQ==&print=1 1/2 Proposed Lighting Power Density Fixture Type Fixture ID Quantity of Fixtures (#F) Watts or Wattage Limit Total Linear per Fixture Feet (LF) (WpF) Watts per Linear Foot (WpLF) Total Watts Proposed (#F x WpF) or (LF x WpLF) Individual Fixtures Troffer A, AE 4 59 236 Troffer B, BE 7 36 252 Suspended Cl, CIE 7 50 350 Suspended D1, DIE 16 50 800 Suspended C, CE 76 100 7,600 Suspended D, DE 14 100 1,400 hftps://waenergycodes.com/print_project_summary_form.php?k=aWQ9NDgl NCZmdmk9MTgmY3RpPQ==&print=1 1/2 E:7INPOVAI https://waenergycodes.com/print_project_Summary_form.php?k=aWQ9NDgl NCZmdmk9MTgmY3RpPQ==&print=1 Proposed Total LPD 1 10638 Project Title Harbor Freight Tools - 2018 WSEC Date I Aug 12, 2021 Proposed Fixtures Details ALTERATION - INTERIOR LIGHTING (50`%) or more replaced) Fixture Type/Application Fixture ID Location in Documents Lamp Type New or Existing -to -Remain Individual Fixtures Troffer A, AE Offices LED New Fixture Description: 2'x4' LED Recessed Fixture Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Troffer B, BE I Restrooms & Breakroom & Vestibule LED New Fixture Description: 2'x4' LED Recessed Fixture Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Suspended Cl7C 1—ESales LED New Fixture Description: 4' LED Strip Fixture Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Suspended DI, DIE I Sales Replenishment LED New Fixture Description: 4' LED Strip Fixture Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Suspended C, CE I Sales LED New Fixture Description: T LED Strip Fixture Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Suspended D, DE I Sales Replenishment LED New Fixture Description: 8' LED Strip Fixture Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required https://waenergycodes.com/print_project_summary_form.php?k=aWQ9NDgl NCZmdmk9MTgmY3RpPQ==&print=1 2/2