2021.0043 UNIT A 2018 Energy(07/01/13) Simple Heating System Size: Washington State This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please complete the green drop-downs and boxes that are applicable to your project. As you make selections in the drop-downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop-down options, please contact the WSU Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance. Project Information Contact Information YELM APTS JERRY SCHUUR PO BOX 597 PUYALLUP, WA 98371 UNIT A- ALL UNITS Heating System Type: To see detailed instructions for each section, place your cursor on the word "Instructions" Design Temperature Instructions Design Temperature Difference (∆T)53 ∆T = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft)1,113 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft)9.0 10,017 Glazing and Doors U-Factor X Area =UA Instructions 0.280 120 33.60 Skylights U-Factor X Area =UA Instructions 0.50 --- Insulation Attic U-Factor X Area =UA Instructions 0.026 1,113 28.94 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions No selection --- Above Grade Walls (see Figure 1)U-Factor X Area UA Instructions 0.056 928 51.97 Floors U-Factor X Area UA Instructions ---________ Below Grade Walls (see Figure 1)U-Factor X Area UA Instructions No selection --- Slab Below Grade (see Figure 1)F-Factor X Length UA Instructions No selection --- Slab on Grade (see Figure 1)F-Factor X Length UA Instructions 0.540 136 73.44 Location of Ducts Instructions Duct Leakage Coefficient 1.00 Sum of UA 187.95 Envelope Heat Load 9,961 Btu / Hour Sum of UA x ∆T Air Leakage Heat Load 5,734 Btu / Hour Volume x 0.6 x ∆T x 0.018 Building Design Heat Load 15,695 Btu / Hour Air leakage + envelope heat loss Building and Duct Heat Load 15,695 Btu / Hour Ducts in unconditioned space: sum of building heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 19,619 Btu / Hour Building and duct heat loss x 1.40 for forced air furnace Building and duct heat loss x 1.25 for heat pump Above Grade Below Grade Figure 1. All Other Systems Heat Pump Lacey No Ducts R-10 Perimeter Select conditioning Select R-value No Floors above unconditioned spaces. R-21 Intermediate Select R-Value R-49 U-0.28 Window, Skylight and Door Schedule Project Information Contact Information YELM APTS JERRY SCHUUR PO BOX 597 PUYALLUP, WA 98371 UNIT A Width Height Ref.U-factor Qt.Feet Inch Feet Inch Area UA Exempt Swinging Door (24 sq. ft. max.)MFR 0.30 1 3 6 8 20.0 6.00 Exempt Glazed Fenestration (15 sq. ft. max.)0.0 0.00 Vertical Fenestration (Windows and doors) Component Width Height Description Ref.U-factor Qt.Feet Inch Feet Inch Area UA BED 2 MFR 0.28 1 5 4 20.0 5.60 BED 3 0.28 1 5 4 20.0 5.60 MSTR BED 0.28 3 2 6 4 30.0 8.40 0.0 0.00 LIVING ROOM 0.28 1 7 6 4 30.0 8.40 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 Sum of Vertical Fenestration Area and UA 100.0 28.00 Vertical Fenestration Area Weighted U = UA/Area 0.28 Overhead Glazing (Skylights) Component Width Height Description Ref.U-factor Qt.Feet Inch Feet Inch Area UA 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 Sum of Overhead Glazing Area and UA 0.0 0.00 Overhead Glazing Area Weighted U = UA/Area 0.00 Total Sum of Fenestration Area and UA (for heating system sizing calculations)120.0 34.00