Loading...
ENERGY 3-2018 Heating System Sizing Worksheet-BLDG 1(07/01/13) Simple Heating System Size: Washington State This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please complete the green drop-downs and boxes that are applicable to your project. As you make selections in the drop-downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop-down options, please contact the WSU Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance. Project Information Contact Information YELM APTS JERRY SCHUUR BLDG 1 PO BOX 597 PUYALLUP, WA 98371 UNIT D- ALL 8 UNITS Heating System Type: To see detailed instructions for each section, place your cursor on the word "Instructions" Design Temperature Instructions Design Temperature Difference (∆T)53 ∆T = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft)1,040 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft)9.0 9,360 Glazing and Doors U-Factor X Area =UA Instructions 0.280 140 39.20 Skylights U-Factor X Area =UA Instructions 0.50 --- Insulation Attic U-Factor X Area =UA Instructions 0.026 1,040 27.04 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions No selection --- Above Grade Walls (see Figure 1)U-Factor X Area UA Instructions 0.056 928 51.97 Floors U-Factor X Area UA Instructions No selection --- Below Grade Walls (see Figure 1)U-Factor X Area UA Instructions No selection --- Slab Below Grade (see Figure 1)F-Factor X Length UA Instructions No selection --- Slab on Grade (see Figure 1)F-Factor X Length UA Instructions 0.540 136 73.44 Location of Ducts Instructions Duct Leakage Coefficient 1.00 Sum of UA 191.65 Envelope Heat Load 10,157 Btu / Hour Sum of UA x ∆T Air Leakage Heat Load 5,358 Btu / Hour Volume x 0.6 x ∆T x 0.018 Building Design Heat Load 15,515 Btu / Hour Air leakage + envelope heat loss Building and Duct Heat Load 15,515 Btu / Hour Ducts in unconditioned space: sum of building heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 19,394 Btu / Hour Building and duct heat loss x 1.40 for forced air furnace Building and duct heat loss x 1.25 for heat pump Above Grade Below Grade Figure 1. All Other Systems Heat Pump Lacey No Ducts R-10 Perimeter Select conditioning Select R-value Select R-Value R-21 Intermediate Select R-Value R-49 U-0.28