Loading...
FIRE ALARM SUBMITTAL - 1063-MRCSB 500 Cherry Street SE 360.353.3157 Olympia WA 98501 LIC# BETSCEC157BP | UBI: 600-535-868 500 Cherry Street SE 360.353.3157 Olympia WA 98501 LIC# BETSCEC157BP | UBI: 600-535-868 500 Cherry Street SE 360.353.3157 Olympia WA 98501 LIC# BETSCEC157BP | UBI: 600-535-868 500 Cherry Street SE 360.353.3157 Olympia WA 98501 LIC# BETSCEC157BP | UBI: 600-535-868 24 1063 5 1.2 Date: 9/14/2021 10 Panel ID: Model:2.5 Amps Location: Volts: 24 VDC 2.5 Amps Wire AWG Ohms Per Length(ft) Actual Volts @ Standby Alarm & Type 1000 Ft. One-Way Ohms EOL IFP-75 1 0.165 0.310 IDP-Photo, Photo-T,PhotoR 0.0000 0.0000 IDP-Fire-CO 0.0000 0.0000 IDP-Heat, Heat-HT, ROR 0.0000 0.0000 IDP-Beam, Beam-T 0.0000 0.0000 DNR 0.0000 0.0000 IDP-IDP Acclimate 0.0000 0.0000 IDP-Photo W Photo W 1 0.0002 0.0045 IDP-Photo-R-W Photo-R-W 0.0000 0.0000 IDP-Photo-T-W Photo-T-W 0.0000 0.0000 IDP-Heat-W Heat-W 0.0000 0.0000 IDP-Heat-ROR-W Heat-ROR-W 0.0000 0.0000 IDP-Heat-HT-W Heat-HT-W 0.0000 0.0000 IDP-Control 0.0000 0.0000 IDP-Control-6 0.0000 0.0000 IDP-Monitor, Minimon 2 0.0008 0.0008 IDP-Monitor-2 0.0000 0.0000 IDP-Monitor-10 0.0000 0.0000 IDP-Pull-SA, Pull-DA 1 0.0004 0.0004 IDP-Relay 3 0.0008 0.0008 IDP-Relay-6 0.0000 0.0000 IDP-RelayMon-2 RelayMon-2 0.0000 0.0000 IDP-Zone 0.0000 0.0000 IDP-Zone-6 Zone-6 0.0000 0.0000 IDP-Iso (Isolator Module)0.0000 0.0000 IDP-ISO-6 0.0000 0.0000 B224BI 0.0000 0.0000 B200SR 0.0000 0.0000 B200S 0.0000 0.0000 B200SR-LF 0.0000 0.0000 B200S-LF 0.0000 0.0000 B224RB 0.0000 0.0000 RTS151 0.000 0.0000 RTS151KEY 0.000 0.0000 RA100Z 0.000 0.000 RA-2000 LCD Remote Annunc 0.000 0.000 RA-100 1 0.020 0.025 RA-1000 0.000 0.000 5824 0.000 0.000 5496 1 0.010 0.010 RPS-1000 0.000 0.000 CELL-MOD Communicator 0.000 0.000 SK-NIC Network Interface Card 0.000 0.000 SK-FML Fiber Module 0.000 0.000 SK-FSL Fiber Module 0.000 0.000 WIDP-WG1 Wireless Gateway 0.000 0.000 5865-4 0.000 0.000 5865-3 0.000 0.000 5880 0.000 0.000 5883 0.000 0.000 NAC #1-C WIRE ####0.000 0.520 #14 Solid 2.52 200 1.01 19.88 2.57% NAC #2-D WIRE ####0.000 0.775 #14 Solid 2.52 200 1.01 19.62 3.83% 0.197 1.646 24 0.083 (5 Mins) 4.730 0.137 4.87 %DropCurrent DrawPart.# Description Qty Relay Module Smoke detector Beam detector Standby Hours: Alarm Mins: Derating Factor: Project Name: Modern Resources Cabinet Shop Project ID: Prepared By: KLM Total Combined AH Required IFP-75 Calculations -IDP Max NAC Current: Max Panel Current: MECH/ELEC RM 108 Version 04.16.18 IFP-75 IDP Devices IFP-75 Fire Alarm Control Panel Voltage Drop Warning Threshold % : Relay-6 Total Alarm AH Required Minimum Battery AmpHours Required 5.84 1.20Multiply By The Derating Factor Total Standby AH Required Monitor, Minimon Zone Total Alarm Current (Amps)Total Standby Current (Amps) Alarm Time In Minutes / 60Standby Time In Hours Notification Appl Circuit Notification Appl Circuit LED Driver Module LED Annunciator (3G) Intelligent Sounder Base LF IDP Acclimate Control-6 Fire-CO detector Monitor-2 Power Expander Power Expander Serial/Parallel Module LCD Remote Annunc Duct housing Heat detector Relay LED Annunciator (4G) LCD Remote Annunc Sounder Base Relay Base Magnetic Remote Test Intelligent Sounder Base Key Activated Test Sounder Base LF Control N/A N/A IFP-75 Addr. Fire Panel Remote LED Iso (Isolator Module) ISO-6 Isolator Base Monitor-10 Pull-SA, Pull-DA Global Project Values: Configure Circuits Print Page Project Name:Modern Resources Cabinet Shop Prepared By:KLM Ckt. Number: NAC #1-C WIRE Panel ID: Ckt. Name: Notification Appl Circuit Use: Standby Alarm Standby Alarm 3 System Sensor SCL Ceiling Strobe (15 cd) 0.000 0.041 0.000 0.123 1 System Sensor SCL Ceiling Strobe (75 cd) 0.000 0.111 0.000 0.111 1 System Sensor PC2L Ceiling Horn/Strobe (75 cd)0.000 0.147 0.000 0.147 1 System Sensor P2L Wall Horn/Strobe (75 cd) 0.000 0.139 0.000 0.139 0.000 0.000 Totals 0.000 0.520 Ckt. Number: NAC #2-D WIRE Panel ID: Ckt. Name: Notification Appl Circuit Use: Standby Alarm Standby Alarm 2 System Sensor SL Wall Strobe (95cd) 0.000 0.121 0.000 0.242 1 System Sensor PC2L Ceiling Horn/Strobe (95 cd)0.000 0.165 0.000 0.165 1 System Sensor P2/PC2 Horn/Strobe (115cd) 0.000 0.229 0.000 0.229 1 System Sensor P2L Wall Horn/Strobe (75 cd) 0.000 0.139 0.000 0.139 0.000 0.000 Totals 0.000 0.775 Qty IFP-75 IDP Devices Qty Device Current Draw Each Current Draw Total Circuit Configuration Current Draw Each Current Draw TotalDevice IFP-75 IDP Devices 1063 9/14/2021 Project ID: Date: Project Information 24 1063 5 1.2 Date: 9/14/2021 10 Panel ID: Model:3.0 Amps Location: Volts: 24 VDC 6.0 Amps Wire AWG Ohms Per Length(ft) Actual Volts @ Standby Alarm & Type 1000 Ft. One-Way Ohms EOL 5496 1 0.040 0.160 NAC #1-G ####0.000 0.477 #14 Solid 2.52 200 1.01 19.92 2.36% NAC #2-H ####0.000 0.624 #14 Solid 2.52 200 1.01 19.77 3.08% NAC #3 ####0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% NAC #4 ####0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% 0.040 1.261 24 0.083 (5 Mins) 0.960 0.105 Total Alarm Current (Amps)Total Standby Current (Amps) Alarm Time In Minutes / 60 Minimum Battery AmpHours Required 1.28 1.07Total Combined AH Required Total Alarm AH Required Command Shortcuts Total Standby AH Required 5496 Power Expander Calculations Max NAC Current: Max Panel Current: MECH/ELEC RM 108 Version 02.24.09 5496 5496 Power Expander Voltage Drop Warning Threshold % : Standby Hours: Alarm Mins: Derating Factor: Project Name: Modern Resources Cabinet Shop Project ID: Prepared By: KLM 1.20Multiply By The Derating Factor Notification Appl Circuit Standby Time In Hours Notification Appl Circuit Notification Appl Circuit Notification Appl Circuit %DropCurrent Draw 5496 Pwr Module Part.# Description Qty Global Project Values: Configure Circuits Print Page Project Name:Modern Resources Cabinet Shop Prepared By:KLM Ckt. Number: NAC #1-G Panel ID: Ckt. Name: Notification Appl Circuit Use: Standby Alarm Standby Alarm 1 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.066 1 System Sensor S/SC Strobe (30cd) 0.000 0.094 0.000 0.094 1 System Sensor P2/PC2 Horn/Strobe (30cd) 0.000 0.116 0.000 0.116 1 System Sensor P2/PC2 Horn/Strobe (95cd) 0.000 0.201 0.000 0.201 0.000 0.000 Totals 0.000 0.477 Ckt. Number: NAC #2-H Panel ID: Ckt. Name: Notification Appl Circuit Use: Standby Alarm Standby Alarm 1 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.066 1 System Sensor S/SC Strobe (95cd) 0.000 0.181 0.000 0.181 1 System Sensor P2/PC2 Horn/Strobe (95cd) 0.000 0.201 0.000 0.201 1 System Sensor P2/PC2 Horn/Strobe (75cd) 0.000 0.176 0.000 0.176 0.000 0.000 Totals 0.000 0.624 Ckt. Number: NAC #3 Panel ID: Ckt. Name: Notification Appl Circuit Use: Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 Circuit Configuration Current Draw Each Current Draw TotalDevice 5496 1063 9/14/2021 Project ID: Date: Qty 5496 Qty Device Current Draw Each Current Draw Total 5496 Qty Device Current Draw Each Current Draw Total Project Information 500 Cherry Street SE 360.353.3157 Olympia WA 98501 LIC# BETSCEC157BP | UBI: 600-535-868 500 Cherry Street SE 360.353.3157 Olympia WA 98501 LIC# BETSCEC157BP | UBI: 600-535-868 FEATURES & BENEFITS • Network support for up to 32 Sites • Built-in support for up to 75 IDP/SK detectors and 75 IDP/SK modules or 75 SD SLC devices • Four line LCD display with 40 characters per line • Available in a red or black cabinet • IFP-75 can be surface or flush mounted • Built-in USB interface for convenient and quick programming • Programmable date setting for Daylight Saving Time • JumpStart AutoProgramming® feature for easy programming • Built-in dual phone line, digital alarm communicator/ transmitter (DACT), IP or optional cellular technologies • Network card allows copper network connection with a multi-mode or single-mode fiber connection option • Convenient field-upgradeable firmware • Supports up to four SWIFT wireless gateways. Each gateway can have up to 49 wireless devices • Supports Class B (Style 4) and Class A (Style 6 or Style 7 configuration for SLC, and SBUS • Built in synchronization for appliances from AMSECO, Gentex®, System Sensor ®, and Wheelock • Reports events to central station by point or by zone IFP-75 / IFP-75B Intelligent Fire AlarmControl Panel The IFP-75 (red) and IFP-75B (black) are intelligent addressable fire alarm control panels (FACP). IFP-75 has a single line circuit (SLC) loop for connecting addressable detectors, which can support 75 System Sensor ® IDP/SK sensors and 75 IDP/SK modules or 75 Hochiki® SD devices per loop. For IDP or SK devices the overall point capacity to a maximum of 150 points per panel, or for SD devices the overall point capacity to a maximum of 75 points per panel. IFP-75 has the interconnection capability for up to 32 panels. The system has two modes of operation, multiple panels covering one larger building, or multiple independent buildings. To network panels together use the SK-NIC network interface card. Copper wire or fiber optic cable panel connectivity can be used within the same networked system. IFP-75 has a built-in dual-line digital and IP communicator with an optional cellular communication module, Form C trouble relay, and two programmable Form C relays. IFP-75 has powerful features such as detector sensitivity, day/night thresholds, drift compensation, pre-trouble maintenance alert, and calibration trouble alert. The IFP-75 supports a variety of devices, including RA-2000, RA-1000 or RA-100 remote annunciator, 5824 serial/parallel printer interface module (for printing system reports), RPS-1000 power module, and IDP, SK, SWIFT wireless or SD devices.. IFP-75B For a complete listing of all compliance approvals and certifications, please visit www.farenhyt.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. SWIFT® and Honeywell® are registered trademarks of and Farenhyt™ is a trademark of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 800-446-6444. IFP-75 Technical Specifications PHYSICAL Overall Dimensions: 15.12”H x 12.71"W x 3.33”D Shipping Weight: 15 lbs. Color: Red or Black ENVIRONMENTAL Operating Temperature: 32°F to 120°F (0°C to 49°C) Humidity: 0 to 93% relative humidity (non- condensing) ELECTRICAL: IFP-75 Primary AC: 120 VAC @ 60 Hz, 1.5A Total Total Accessory Load:2.5A @ 27.4VDC power- limited Standby Current: 165mA Alarm Current: 310mA Battery Charging Capacity: 7 to 35AH Battery Size: 7AH max. allowed in control panel cabinet. Larger capacity batteries can be housed in RBB accessory cabinet. AGENCY LISTINGS AND APPROVALS NFPA 13, NFPA 15, NFPA 16, NFPA 70, & NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service • UL Listed • CSFM: 7165-0559:0503 • FDNY COA# 6248 • Seismic (CA) (pending), APPROVED RELEASING SOLENOIDS Asco T8210A107 24 VDC 3 A max 0 Hz Asco 8210G207 24 VDC 3 A max 0 Hz COMPATIBLE DEVICES See the data sheets listed below for a complete listing of the IDP, SK, SWIFT or SD devices. 350361: IDP Device Protocol data sheet 53623: SK Device Protocol data sheet 350360: SD Device Protocol data sheet 350615 & 350617: SWIFT devices data sheet ORDERING INFORMATION IFP-75: Intelligent Fire Alarm Control Panel. Red Cabinet. IFP-75B: Intelligent Fire Alarm Control Panel Black Cabinet. SBUS ACCESSORIES RA-2000, RA-1000, RA-1000R, RA-100, RA-2000GRAY: Remote annunciators 6815: Signal Line Circuit (SLC) Expander for IDP or SK devices 5815XL: Signal Line Circuit (SLC) Expander for SD devices RPS-1000: Power Supply 5496: NAC Expander 5824: Serial/Parallel Module 5880: LED I/O Module 5865-3 or 5865-4: LED Annunciator 5883: Relay Interface MISCELLANEOUS ACCESSORIES HFSS: Software Suite. Provides programming, upload/download and event reporting RBB: Remote Battery Box Cabinet. Use for backup batteries up to 35 AH. Dimensions: 16"W x 10"H x 6"D SK-SCK: Seismic Compliance Kit SK-NIC: Network Interface Card SK-FML: Multi Mode Fiber Card SK-FSL: Single Mode Fiber Card CELL-MOD: Cellular Communicator in Plastic Enclosure CELL-CAB-SK: Cellular Communicator in Metal Enclosure with lock and key 351605 | A | 04/18 © 2018 Honeywell International Inc. For more information Learn more about Honeywell’s Farenhyt Series and other products available by visiting www.farenhyt.com Honeywell Farenhyt 12 Clintonville Road Northford, CT 06472 800-328-0103 500 Cherry Street SE 360.353.3157 Olympia WA 98501 LIC# BETSCEC157BP | UBI: 600-535-868 FEATURES & BENEFITS • 80-character backlit LCD display (4 lines with 20 characters on each line) • Tactile/audible feedback • RS-485 SBUS interface to panel • Larger keypad buttons for system reset and silence • Initiate and end fire drills with a single key press • View current status by alarms, supervisories, or troubles • On-board piezo sounder audibly indicates alarms, troubles, and supervisories • Five Status LEDs for; alarms, supervisory, trouble, silence and AC power indications • Available in red color • Wiring lengths up to 6000 ft. from the control panel • UL listed • Complies with NFPA 72 • Accepts user codes or fire fighter’s key • Support for simultaneous use of multiple RA-100s • Can be flush- or surface mounted. Trim ring available for surface mounting. RA-100 Remote Annunciator The RA-100 Remote Annunciator can be used to operate and program the Farenhyt Series Fire Control Panels. The remote annunciator connects to the control panel via the RS- 485 system bus. When the system is in normal operation and has AC power, the Power LED is lit and all other LEDs are off. The other LEDs turn on as alarms, supervisories, troubles, system silenced and AC power losses occur INSTALLATION The RA-100 can be surface or flush mounted. Use the optional trim ring for surface mounts. When flush mounting an electrical box is optional. If using an electrical box, use a 4S, single-gang, or double-gang box. COMPATIBILITY The RA-100 is compatible with the following Farenhyt Series FACPs: • IFP-2100 / IFP-2100ECS • IFP-1000/ECS • IFP-100/ECS • IFP-300 / IFP-300ECS • IFP-75 • IFP-50 RA-100 For a complete listing of all compliance approvals and certifications, please visit www.farenhyt.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Honeywell® is a registered trademarks of and Farenhyt™ is a trademark of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, Please call 800-446-6444. RA-100 Technical Specifications PHYSICAL Flush Mount: (Outside wall)12.25”W x 11.5”H x 7/8”D (31.1W x 29.2H x 2.2D cm) (Inside wall)9-3/8”W x 8-3/8”H x 2”D (23.8W x 21.3H x 5.1D cm) Surface Mount: (Including Trim Ring) 12.25”W x 11.5”Hx 3”D (31.1W x 29.2H x 2.2D cm)) ENVIRONMENTAL Operating Temperature: 32°F to 120°F (0°C to 49°C) Humidity: 10% to 93% relative humidity (non- condensing) ELECTRICAL: Operating Voltage: 24VDC Standby Current: 20mA Alarm Current: 25mA Wiring Distance: Up to 6,000 ft max. from FACP (depending on wiring method). Max per System: IFP-50 or IFP-75 (8); IFP-100/ ECS or IFP-1000/ECS (12); IFP-300/ECS (16); IFP-2100/ECS (31) ORDERING INFORMATION RA-100: Remote Annunciator. Four line LCD annunciator with 20 characters per line. OPTIONAL ACCESSORIES RA-100TR: Red. Surface Mount Trim Ring AGENCY LISTINGS AND APPROVALS • MEA Approved • CSFM Approved • FM Approved • UL listed Doc 350389| Rev G | 12/17 © 2017 Honeywell International Inc. For more information Learn more about Honeywell’s Farenhyt Series and other products available by visiting www.farenhyt.com> Honeywell Security & Fire 12 Clintonville Road Northford, CT 06472 800-328-0103 500 Cherry Street SE 360.353.3157 Olympia WA 98501 LIC# BETSCEC157BP | UBI: 600-535-868 FEATURES & BENEFITS • UL Listed for 6 amps of notification power • Power supply’s advanced switch mode design reduces damaging heat and manages power up to 50% more efficiently than other systems • 24 VDC filtered output voltage • Built-in synchronization for appliances from Gentex, AMSECO, System Sensor, and Wheelock • Four power-limited notification outputs; 2 Class A or 4 Class B, or 1 Class A and 2 Class B • NACs are programmable as notification appliance circuits, or as auxiliary power to be used as constant, resettable, or door holder power • 3 amps per output circuit • Ground fault detector • CSFM approved • Communicates to the FACP via 4-wire SBUS (wire runs up to 6000 ft) • AC loss delay option shuts off power to non-essential high current accessories like magnetic door holders • MEA approved • Lightweight design adds to ease of installation and reduces shipping costs • ANSI Cadence pattern output capability built-in • UL 864,1481 & 1971 listed • OSHPD (CA) OSP-0065-10 (see accessories) 5496 Intelligent Power Module The 5496 intelligent power module is the most cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor®,Gentex®, AMSECO, and Wheelock®. The 5496’s advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. The 5496 is a 6 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery for use with the Honeywell Silent Knight series fire alarm control panels (FACPs). The 5496 is the cost-effective solution for powering notification appliances required by the Americans with Disabilities Act (ADA). The 5496 has built-in ANSI cadence pattern. The output circuits can be programmed as notification appliance circuits, or as auxiliary power (configurable for constant, resettable, or door holder power). Compatibility The 5496 is compatible with the following Honeywell Silent Knight FACPs: • 6820 / 6820EVS • 5820XL / 5820XL-EVS • 6808 • 6700 • 5808 • 5700 5496 For a complete listing of all compliance approvals and certifications, please visit www.silentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. System Sensor® and Honeywell® are registered trademarks of Honeywell International, Inc This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 800-446-6444 5496 Technical Specifications PHYSICAL Overall Dimensions: 16" H x 12.25" W x 3" D (40.6 x 30.9 x 7.6 cm) Shipping Weight: 8.7lbs ENVIRONMENTAL Operating Temperature: 32°F to 120°F (0°C to 49°C) Humidity: 10 to 93% relative humidity (non- condensing) ELECTRICAL: AC Input: 120VAC at 2.7A Output: 24VDC at 6A Standby & Alarm Current: 10mA Notification/Aux. Power Circuits: 4 Output Configuration: 2 Class A (Style Z) 4 Class B (Style Y) 1 Class A & 2 Class B Amps Per Output Circuit: 3.0 (6.0 amps total) Notification Circuit Output: 20.4 – 27.3VDC @ 3.0A each End-of-Line Resistance: 4.7k W EOL resistor required on each Class B circuit Battery Charging Capacity: 7.0 – 35.0AH ORDERING INFORMATION 5496: Intelligent Power Module ACCESSORIES RBB: Remote Battery Box Accessory Cabinet. 16” W x 10” H x 6” D (406 mm W x 254 mm H x 152 mm D) SK-SCK: Seismic Compliance Kit AGENCY LISTINGS AND APPROVALS • CSFM approved • NFPA 72 • UL listed • FM approved • City of NY: 429-90-E Vol XIV Doc 350387| Rev F| 11/17 © 2017 Honeywell International Inc. For more information Learn more about Silent Knight's Product and other products available by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 www.silentknight.com 500 Cherry Street SE 360.353.3157 Olympia WA 98501 LIC# BETSCEC157BP | UBI: 600-535-868 CompatibilityThe IDP-Pull-SA and IDP-Pull-DA arecompatible with the following FACPs:•IFP-2000 / RPS-2000 Intelligent FirePanel•IFP-1000 / ECS Intelligent Fire Panel•IFP-100 / ECS Intelligent Fire Panel•IFP-50 Intelligent Fire Panel P/N 350286 Rev F© 2013 Honeywell International Inc Addressable Single Action and Dual ActionPull StationsIDP-Pull-SA & IDP-Pull-DAThe IDP-Pull-SA is a single action pull station requiring only onemotion to activate the station. The IDP-Pull-DA is a dual actionpull station requiring two motions to active the station. Both pullstations are designed to work with Silent Knight IFP-series firealarm control panels (FACPs).Features•Installer can open station without causing an alarm condition•Dual-color LED is visible through handle of station blinks greento indicate normal operation and remains steady red in an alarmcondition•Key operated test and reset lock using lock plate actuator•Key matches compatible FACP locks•Meets the Americans with Disabilities Act AccessibilityGuidelines (ADAAG) controls and operating mechanismsguidelines (Section 4.1.3[13])•Meets ADA requirement for 5 lbs maximum pull force to active•Shell, door, and handle molded from durable LEXAN®•Reliable analog communications for trouble-free operation•Braille text on station handle•Handle latches in down position and the word Activatedappears, clearly indicating the station has been pulled•Rotary address switches for fast installation•UL Listed, including UL 38, Standard of Manually ActuatedSignaling System InstallationThe IDP-Pull-SA and IDP-Pull-DA can be surface mounted to anSB-I/O surface back box or semi-flush mounted on a standard single-gang with a minimum depth of 2.13”(5.40 cm) or double-gang or 4” (10.61 cm) square electrical box. You can also use theoptional (System Sensor®PN BG-TR) trim ring if the station isbeing semi-flush mounted. IDP-Pull-SA IDP-Pull-DA MEA67-02-E Vol. IXFor IDP-Pull-DA Agency Listings Specifications*PhysicalHeight: 5.5” (14 cm)Width: 4” (10.2 cm)Depth: 5.4 oz. (3.7 cm)Housing Material: LEXAN polycarbonate resinBi-Colored LED:Blinking Green: NormalSteady Red: AlarmSwitch: Single pole, single throw (SPST) normally open (N/O)switch which closes upon activation of the pull stationElectricalOperating Voltage: 15–32 VDCOperating Current (LED flashing): 300 µAWire Gauge: Up to 12 AWG (3.1 mm2)EnvironmentalOperating Temperature 32º – 120ºF (0ºC – 49ºC)Humidity: 10% – 93% non-condensing Ordering InformationIDP-Pull-SA Single Action Pull StationIDP-Pull-DA Dual Action Pull Station AccessoriesBG-TR Optional trim ring.SB-I/O Surface backbox, indoor/outdoor. * Unless otherwise noted, specifications apply to IDP-Pull-SA and IDP-Pull-DA. Made in the U.S.A. This document is not intended to be used for installation purposes. We try to keep ourproduct information up-to-date and accurate. We cannot cover all specific applicationsor anticipate all requirements. All specifications are subject to change without notice.For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.farenhyt.com InstallationThe IDP-Photo and IDP-Photo-T plug into acompatible IDP-series detector base. TheIDP-PhotoR is a remote test capable detectorfor use with the DNR (W) duct smokedetectorsCompatibilityThe IDP-Photo, IDP-Photo-T and IDP-PhotoRare compatible with the following IDP-seriesdetector bases:•B210LP 6” Mounting Base•B501 4” Mounting Base•B224BI 6” Isolator Base•B224RB 6” Relay Base•B200SR 6” Sounder BaseThe IDP-Photo, IDP-Photo-T and IDP-PhotoRare compatible with the following FACPs:•IFP-2000 / RPS-2000 Intelligent Fire Panel•IFP-2000ECS Emergency CommunicationSystem with Fire Panel•IFP-1000 / ECS Intelligent Fire Panel•IFP-100 / ECS Intelligent Fire Panel•IFP-50 Intelligent Fire Panel•IFP-25 Intelligent Fire Panel P/N 350280 Rev GCopyright © 2015 Honeywell International Inc. Intelligent Photoelectric Smoke Detector& Photoelectric Smoke with ThermalIDP-Photo, IDP-Photo-T and IDP-PhotoRThe IDP-Photo is a photoelectric smoke detector and the IDP-Photo-T is a photoelectric smoke detector with thermal.These plug in smoke detectors, with integral communication,provide features that surpass conventional detectors and arefor use with Silent Knight IFP-series fire alarm control panels(FACPs). Detector sensitivity can be programmed from the FACPsoftware. Sensitivity is continuously monitored and reported tothe FACP. Point ID capability allows each detector ’s addressto be set with rotary address switches, providing exactdetector locations for selective maintenance when chambercontamination reaches unacceptable levels.IDP-Photo and IDP-Photo-T have a unique optical sensingchamber that is engineered to sense smoke produced by awide range of combustion sources. In the IDP-Photo-T, dualelectronic thermistors add 135ºF (57ºC) thermal technology tomaximize detection. The IDP-PhotoR is a remote test capable detector for use withthe DNR (W) duct smoke detectors.Features•Sleek, low-profile design•Reliable analog communications for trouble-free operation•Age resistant polymer housing•Dual electronic thermistor design on the IDP-Photo-T•Superior EMI resistance for reliability•Simple field cleaning for code compliance•Variety of mounting options to meet any application•Dual LED indicators for 360º visibility•Detector transmits signal to indicate maintenance isrequired•Optional remote LED annunciator (System Sensor®PNRA100Z)•Plug-in mounting provides ease of installation•Tamper-proof feature available on mounting bases•Listed for use in duct applications•Rotary address switches for fast installation•UL Listed IDP-Photo (Base not Included) Intelligent Devices MEA225-02-E Vol. V Specifications*PhysicalHeight: 2.0” (5.0 cm)Diameter: 4.1” (10.4 cm) installed in B501 baseElectricalOperating Voltage: 15–32 VDCSLC Standby and Alarm Current: 300 µA EnvironmentalOperating Temperature IDP-Photo: 32º – 120ºF (0ºC – 49ºC)IDP-Photo-T: 32º – 100ºF (0ºC – 38ºC)Humidity: 10% – 93% non-condensingOther RatingsIDP-Photo-T Thermal: Fixed temperature setpoint 135ºF(57ºC)Velocity: 0 – 4000 fpm (0 – 20 m/sec) (suitable forinstallation in ducts)IDP-Photo Insect Screen Hole Size: 0.016” (0.41 mm)nominal Ordering Information IDP-Photo Photoelectric Smoke DetectorIDP-Photo-T Photoelectric Smoke Detector withThermal (135ºF)IDP-PhotoR Photoelectric smoke detector, remotetest capable, for use with DNR (W) ductsmoke detectorAccessoriesRA100ZRemote LED Annunciator.XR2B Detector Removal Tool. A removal andreplacement tool for IDP plug-indetectors. Includes the T55-127-000.M02-04-01 Detector Test Magnet.M02-09-00 Test Magnet with Telescoping Handle.XP-4 Extension Pole for XR2B. Extends from 5 – 15 ft.T55-127-000 Detector Removal Head.BCK-200B Black Detector Kit. For IDP-seriesdetectors.* Unless otherwise noted, specifications apply to IDP-Photo and IDP-Photo-T. Wiring IDP-Series Detector Mounting Bases This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specificationsare subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road,Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.farenhyt.com 500 Cherry Street SE 360.353.3157 Olympia WA 98501 LIC# BETSCEC157BP | UBI: 600-535-868 Agency Listings 7125-1653:0504 7135-1653:0503 S5512 S4011 FM approved except for ALERT models 3057383, 3057072 AVDS865-05 • 2/22/2018 • Page 1 Features • Updated Modern Aesthetics • Small profile devices for Horns and Horn Strobes • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field-selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Strobes and Horn Strobes listed for wall mounting only • Horns listed for wall or ceiling use The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. AVDS865-05 • 2/22/2018 • Page 2 L-Series Specifications Architect/Engineer Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 17/8-inch back box, 4 × 4 × 1½-inch back box, 4-inch octagon back box, or double-gang back box. L-Series compact products shall mount to a single-gang 2 × 4 × 17⁄8 -inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize Strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 × 411/16 × 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens)5.6˝ L × 4.7˝ W × 1.91˝ D (143 mm L × 119 mm W × 49 mm D) Compact Wall-Mount Dimensions (including lens)5.26” L x 3.46” W x 1.91” D (133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6˝ L × 4.7˝ W × 1.25˝ D (143 mm L × 119 mm W × 32 mm D) Compact Horn Dimensions 5.25” L x 3.45” W x 1.25” D (133 mm L x 88 mm W x 32 mm D) 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. AVDS865-05 • 2/22/2018 • Page 3 Horn and Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9*Coded High 85 90 90 10*3.1 KHz Coded High 84 89 89 * Settings 9 and 10 are not available on 2-wire horn strobes. Temporal coding must be provided by the NAC. If the NAC voltage is held constant, the horn output remains constantly on. UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC DC FWR Candela Range 15 88 43 60 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 UL Max. Current Draw (mA RMS), Wall Horn Strobe, Candela Range (15–185 cd) DC Input 8–17.5 Volts 16–33 Volts 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 FWR Input 16–33 Volts 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 UL Max. Horn Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Current Draw Data Horn Tones and Sound Output Data 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2018 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS865-05 • 2/22/2018 L-Series Dimensions Model Description Wall Horn Strobes P2RL 2-Wire, Horn Strobe, Red P2WL 2-Wire, Horn Strobe, White P2GRL 2-Wire, Compact Horn Strobe, Red P2GWL 2-Wire, Comp 2 fils act Horn Strobe, White P2RL-P 2-Wire, Horn Strobe, Red, Plain P2WL-P 2-Wire, Horn Strobe, White, Plain P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO P2WL-SP 2-Wire, Horn Strobe, White, FUEGO P4RL 4-Wire, Horn Strobe, Red P4WL 4-Wire, Horn Strobe, White Wall Strobes SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT L-Series Ordering Information Notes: All -P models have a plain housing (no “FIRE” marking on cover). All -SP models have “FUEGO” marking on cover. All -ALERT models have “ALERT” marking on cover. *Horn-only models are listed for wall or ceiling use. Model Description Horns* HRL*Horn, Red HWL*Horn, White HGRL*Compact Horn, Red HGWL*Compact Horn, White Accessories TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBRL Wall Surface Mount Back Box, Red SBBWL Wall Surface Mount Back Box, White SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, White 4.70" (11.94 cm)1.91" (4.85 cm) 1.25" (3.18 mm) 5.67" (14.4 cm) A0549-00A0550-00 Compact Strobe, Horn Strobe Compact Horn Strobe, Horn Strobe Horn A0548-00 A0547-00 4.7" 119 mm 5.67" 144 mm 1.25" 32 mm 3.46" 88 mm 1.91" 48.5 mm 1.25" 32 mm 5.27" 133.9 mm 3.46" 88 mm 1.25" 32 mm 5.27" 133.9 mm Wall Surface Mount Back Box SBBRL/SBBWL A0554-01 4.82" (12.24 cm)1.85" (4.69 cm) 5.78" (14.68 cm) A0557-00 1.55" (3.9 cm) 3.57" (9.1 cm) 5.38" (13.7 cm) Compact Wall Surface Mount Back Box SBBGRL, SBBGWL Features • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Listed for ceiling mounting only The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Agency Listings 7125-1653:0504 7135-1653:0503 S5512 S4011 FM approved except for ALERT models 3057383 AVDS868-02 • 12/01/2017 • Page 3 AVDS868-02 • 12/01/2017 • Page 2 L-Series Specifications Architect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 × 4 × 1½-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 × 4 × 17⁄8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11 ⁄16 × 4 11 ⁄16 × 2 1 ⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3)8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens)6.8" diameter × 2.5" high (173 mm diameter × 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions (SBBCRL, SBBCWL) 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS868-02 • 12/01/2017 • Page 3 Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 UL Current Draw Data Horn Strobe Tones and Sound Output Data UL Max. Horn Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC DC FWR Candela Range 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 UL Max. Current Draw (mA RMS), Ceiling Horn Strobe, Candela Range (15–177 cd) DC Input 8–17.5 Volts 16–33 Volts 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1K Temporal High 111 164 69 94 147 163 184 229 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 FWR Input 16–33 Volts 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2017 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS868-02 • 12/01/2017 L-Series Dimensions Model Description Ceiling Horn Strobes PC2RL 2-Wire, Horn Strobe, Red PC2WL 2-Wire, Horn Strobe, White PC4RL 4-Wire, Horn Strobe, Red PC4WL 4-Wire, Horn Strobe, White L-Series Ordering Information Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box Model Description Ceiling Strobes SCRL Strobe, Red SCWL Strobe, White SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White 6.83" diam. (173 mm) 2.47" (62.7 mm) 1.37" (34.8 mm)6.92" diam. (175.77 mm) 2.5" (64 mm) 2-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box A0531-01 A0545-00 A0546-00 A0494-01 For a ceiling-listed horn-only device, see AVDS865 “Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications”. Agency Listings AVDS115-02 • 12/3/2019 • Page 1 MEA452-05-E3023572 7300-1653:187 (outdoor strobes) 7125-1653:188 (horn strobes, chime strobes) 7135-1653:189 (horns, chimes) S4011 (chimes, horn strobes, horns) S3593 (outdoor and alert strobes) Features • Weatherproof per NEMA 4X, IP56 • Listed to UL 1638 (strobe) and UL 464 (horn) • Compatible with System Sensor synchronization protocol and legacy SpectrAlert products • Field-selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Rotary switch for horn tone and three volume selections • Horn rated at 88+ dBA at 16 volts • Rated from –40°F to 151°F • Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Listed for ceiling or wall mounting SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from −40°F to 151°F. Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field-selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in-and- out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock-outs located on the back eliminate the need to drill holes for screw-in mounting. Plastic and metal weatherproof back boxes come with ¾-inch top and bottom conduit entries and ¾-inch knock-outs at the back. A screw-in NPT plug with an O-ring gasket for a watertight seal is included with each back box. Outdoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert® Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. AVDS115-02 • 12/3/2019 • Page 2 SpectrAlert Advance Outdoor Horn, Strobe, and Horn StrobeSpecifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Outdoor SpectrAlert Advance products shall operate between −40 and 151 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non-coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature –40°F to 151°F (–40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage with MLD3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens)5.6˝ L × 4.7˝ W × 2.5˝ D (142 mm L × 119 mm W × 64 mm D) Horn Dimensions 5.6˝ L × 4.7˝ W × 1.3˝ D (142 mm L × 119 mm W × 33 mm D) Wall-Mount Weatherproof Back Box Dimensions (SA-WBB)5.7˝ L × 5.1˝ W × 2.0˝ D (145 mm L × 130 mm W × 51 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High Candela Range 135 NA NA 228 207 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Standard Candela Range (15–115 cd) DC Input 8–17.5 Volts 16–33 Volts 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, High Candela Range (135–185 cd) DC Input 16–33 Volts FWR Input 16–33 Volts 135 150 177 185 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 UL Max. Horn Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-Temporal High 57 56 69 75 Non-Temporal Medium 42 50 60 69 Non-Temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 UL Current Draw Data Horn Tones and Sound Output DataCandela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Strobe Output (cd) Listed Candela Candela rating at –40°F 15 Do not use below 32°F15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 Horn and Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts 24-Volt Nominal Reverberant Anechoic DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- Temporal High 82 82 88 88 93 92 100 100 5 Non- Temporal Medium 78 78 85 85 90 90 98 98 6 Non- Temporal Low 75 75 81 81 88 84 96 92 7†Coded High 82 82 88 88 93 92 101 101 8†Coded Medium 78 78 85 85 90 90 97 98 9†Coded Low 75 75 81 81 88 85 96 92 †Settings 7, 8, and 9 are not available on 2-wire horn strobe. 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2019 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS115-02 • 12/3/2019 SpectrAlert Advance Diagrams Model Description Red White Wall Horn Strobes P2RK P2WK 2-Wire Horn Strobe, Standard cd, Outdoor (includes plastic weatherproof back box) P2RK-P P2WK-P 2-Wire Horn Strobe, Standard cd, Outdoor, Plain (includes plastic weatherproof back box) P2RK-R P2WK-R 2-Wire Horn Strobe, Standard cd, Outdoor (does not include plastic weatherproof back box) P2RHK P2WHK 2-Wire Horn Strobe, High cd, Outdoor (includes plastic weatherproof back box) P2RHK-P P2WHK-P 2-Wire Horn Strobe, High cd, Outdoor, Plain (includes plastic weatherproof back box) P2RHK-R P2WHK-R 2-Wire Horn Strobe, High cd, Outdoor (does not include plastic weatherproof back box) P4RK P4WK 4-Wire Horn Strobe, Standard cd, Outdoor (includes plastic weatherproof back box) P4RK-R —4-Wire Horn Strobe, Standard cd, Outdoor (does not include plastic weatherproof back box) P2RHK-120 —2-Wire Horn Strobe, High cd, Outdoor, 120 V (includes plastic weatherproof back box) Wall Strobes SRK SWK Strobe, Standard cd, Outdoor (includes plastic weatherproof back box) SRK-P SWK-P Strobe, Standard cd, Outdoor, Plain (includes plastic weatherproof back box) SRK-R SWK-R Strobe, Standard cd, Outdoor (does not include plastic weatherproof back box) SRHK SWHK Strobe, High cd, Outdoor (includes plastic weatherproof back box) SRHK-P SWHK-P Strobe, High cd, Outdoor, Plain (includes plastic weatherproof back box) SRHK-R SWHK-R Strobe, High cd, Outdoor (does not include plastic weatherproof back box) Horns HRK —Horn, Red, Outdoor (includes plastic weatherproof back box) HRK-R —Horn, Red, Outdoor (does not include plastic weatherproof back box) Accessories SA-WBB SA-WBBW Metal Weatherproof Back Box WTP WTPW Metal Weatherproof Outdoor Flush-mounting Plate SpectrAlert Advance Ordering Information Notes: All -P models have a plain housing (no “FIRE” marking on cover). All -R models require metal weatherproof outdoor flush mounting plate or a metal weatherproof outdoor back box (order separately). “Standard cd” refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. “High cd” refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. 4.7˝ 5.6˝ 6.8˝Dia. 2.5˝ 2.5˝ 64mm119mm 142mm Wall-Mount Horn Strobes Wall Plastic Weatherproof Back Box Wall-Mount Horn Strobe with Plastic Weatherproof Back Box 500 Cherry Street SE 360.353.3157 Olympia WA 98501 LIC# BETSCEC157BP | UBI: 600-535-868 CompatibilityThe IDP-Monitor is compatible with thefollowing FACPs: •IFP-2000 / RPS-2000 Intelligent Fire Panel•IFP-2000ECS Emergency CommunicationSystem with Fire Panel•IFP-1000 / ECS Intelligent Fire Panel•IFP-100 / ECS Intelligent Fire Panel•IFP-50 Intelligent Fire Panel P/N 350288 Rev JCopyright © 2015 Honeywell International Inc. Addressable Monitor ModuleIDP-MonitorThe IDP-Monitor is an addressable monitor module for use withSilent Knight IFP-series fire alarm control panels (FACPs). The IDP-Monitor acts as an interface to contact devices, such aswaterflow switches and pull stations. The IDP-Monitor supports Class A supervised or Class Bsupervised wiring to the load device. Conventional 4-wiresmoke detectors can be monitored for alarm and troubleconditions. Features•Single contact monitor•Support for Class A and Class B wiring•Fully supervised•Panel controlled status LED that flashes green in normal stateand is solid red in alarm•Attractive ivory cover plate•Rotary address switches for fast installation•SEMS screws for easy wiring•UL Listed InstallationThe IDP-Monitor mounts directly into a 4” square electrical box.The box must have a minimum depth of 2-1/8”. A surface mountelectrical box (System Sensor®PN SMB500) is available fromSilent Knight. IDP-Monitor MEA386-0-E-Vol 2 Agency Listings Intelligent Device SpecificationsPhysicalHeight: 4.5” (11.4 cm)Width: 4” (10.2 cm)Depth: 1.25” (3 cm)Shipping Weight: 6.3 oz (196 g)ElectricalOperating Voltage: 15 – 32 VDCSLC Standby and Alarm Current Draw: 350 µAEnd-of-Line Resistance: 47K WMax. IDC wiring resistance: 1,500 WMax. IDC Voltage: 11 VoltsMax. IDC Current: 450 µASLC Loop Resistance: 40 W max. EnvironmentalOperating Temperature: 32ºF – 120ºF (0ºC – 49ºC)Humidity: 10% – 93% non-condensingOrdering InformationIDP-Monitor Monitoring ModuleAccessoriesSMB500 4” Square Surface Mount Electrical Box Typical Wiring for IDP-Monitor Module, NFPA Style D Typical Wiring for IDP-Monitor Module, NFPA Style B This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications aresubject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.farenhyt.com CompatibilityThe IDP-Relay is compatible with thefollowing FACPs:•IFP-2000 / RPS-2000 Intelligent Fire Panel•IFP-2000ECS Emergency CommunicationSystem with Fire Panel•IFP-1000 / ECS Intelligent Fire Panel•IFP-100 / ECS Intelligent Fire Panel•IFP-50 Intelligent Fire Panel•IFP-25 Intelligent Fire PanelInstallationThe IDP-Relay mounts directly into a 4”square electrical box. The box must have aminimum depth of 2-1/8”. A surface mountelectrical box (System Sensor®PN SMB500)is available from Silent Knight. P/N 350290 Rev J© 2015 Honeywell International Inc. Addressable Relay ModuleIDP-RelayThe IDP-Relay is an addressable relay module for use withSilent Knight IFP-series fire alarm control panels (FACPs).The IDP-Relay allows a Silent Knight FACP to switch discretecontacts by code command. The relay contains two isolatedsets of Form C contacts, which operate as a DPDT switch. Nosupervision is provided for the notification appliance circuit.The IDP-Relay contacts can be used for virtually any normallyopen or normally closed application. Each IDP-Relay isprogrammed with a unique signaling line circuit (SLC) loopaddress. When an event occurs that controls the IDP-Relay,the relay is triggered by the FACP. Features•Two sets of Form C contacts•Contacts are rated for a variety of amps (see Specifications)•Panel controlled status LED that flashes green in normalstate and is solid red in alarm•Relay programming is completely flexible–can be mappedto zone conditions•Polling LED visible through the cover plate•Attractive ivory cover plate•Rotary address switches for fast installation•SEMS screws for easy wiring•UL ListedRelay Contact RatingsCurrentRatingMax Voltage LoadDescription Application 3 A 30 VDC Resistive Noncoded 2 A 30 VDC Resistive Coded 0.7 A 70.7 VDC PF = 0.35 Noncoded 0.9 A 125 VAC Resistive Noncoded 0.46 A 30 VDC L/R = 20 ms Noncoded 0.5 A 125 VAC PF = 0.75 Noncoded 0.3 A 125 VAC PF = 0.35 Noncoded 2 A 25 VAC PF= 0.35 Noncoded IDP-Relay MEA386-02-E Vol II Agency Listings SpecificationsPhysical4.675" H x 4.275" W x 1.4" DShipping Weight: 6.3 oz (196 g)EnvironmentalOperating Temperature: 32ºF – 120ºF (0ºC – 49ºC)Humidity: 10% – 93% non-condensingElectricalOperating Voltage: 15 – 32 VDCEnd-of-Line Resistance: Not usedSLC Standby & Alarm Current: .255mA max @ 24 VDC(one communication every 5 sec with LED enabled) Ordering InformationIDP-Relay Relay Module AccessoriesSMB500 4” Square Surface Mount Electrical BoxCB500Module Barrier Assembled in theU.S.A. This document is not intended to be used for installation purposes. We try to keep ourproduct information up-to-date and accurate. We cannot cover all specific applications oranticipate all requirements. All specifications are subject to change without notice. For moreinformation, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone:(800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.farenhyt.com 500 Cherry Street SE 360.353.3157 Olympia WA 98501 LIC# BETSCEC157BP | UBI: 600-535-868 500 Cherry Street SE 360.353.3157 Olympia WA 98501 LIC# BETSCEC157BP | UBI: 600-535-868