Loading...
2021.0536 Walmart Restroom Remodel - 17100 State Route 507 SERR SPECIAL PROJECTPROTO:DATE:EXISTING SQ FT:STORE NO.:Architect of RecordWilliam Douglas HurleyWashington License No. 8855Unified Business ID No. 602 491 6682809 Ajax Avenue Suite 100Rogers Arkansas 72758Phone: 479.636.3545Fax: 479.636.1209YELM, WASHINGTON3705-24010-18-21176184,368REMODELED SQ FT:1,391OGP5D6OGP5D8OGP5D8OGP5D6OGP5D8OGP5D8OGP5D6OGP5D8OGP5D8OOOOOOOOOOOOGP2D8OGP2D8OGP2D8OGP2D8OGP2D8OGP2D8OGP2D8OGP2D8OGP2D6OGP2D6OGP2D6OGP2D8OGR1GR1 MECHANICALSERVICE AREALOCKABLE MENWOMENCENTERVISIONADJUSTMENTSFAMILYFREEZERBREAKROOMRECEIVING-GRBALERCORRIDORMANAGERSTORAGE-GMCARTVESTIBULE-GMSEAFOODPREPPRODUCECOOLER UPC/UPSCOUNTCORRIDOR CART STORAGE-GRSTORAGETIRE/BATTERYCOMPACTORDRIVE-THRUPHARMACYPASS-THRUPASS-THRUPASS-THRUDESKCREDIT UNIONAMERICA'SSTYLESMARTUTILITYDESKCOURTESYEQUIPMENTSTORAGEHOMEMADE BIKE BUILDERSPHARMACYROOM #3ELECTRICALMECHANICALBAKERYCAKE DECORATINGCOOLERCLOSETRISERVISION CENTERCASHBLIMPIE'SUTILITYBAKERYWOMENTOILETADMANAGERCLAIMSLOCKABLE BAKERYJANITORALCOVEDAIRYCOOLERENTRY-GMHAZMATFREEZERGROCERYFREEZERCREAMWORKSTATIONMANAGER'SLOCKABLE LOCKABLEELECTRICAL RETURNUTILITY DELI EQUIPMENT VESTIBULE-GRENTRY-GRPRETESTSTORAGEEXAM #1CONTACTSWAITINGTOILETHALLWAYSTOCKROOMINVOICINGSPRINKLERSTOCKROOM-GMICESTOCKROOM-GR MECHANICAL PLUMBING/ STOCKROOM-GRCOOLERMEATSEAFOODFREEZERPRODUCEBAKERY/DELISERVICE DELIDELI PREPCOOLERDELISTORAGEPLASTICSAPAIR CURTAINROOM #2 RECEIVING-GMSERVICECUSTOMERPERSONNELTRAININGOFFICEOFFICEWAITINGLOCKABLEHAZMAT12345678910111213ABCDEFGHJKJ.1J.4J.84.25.56.56.6G.9H.4H.7G.511.811.710.59.58.88.67.83.83.22.51.5B.6B.7C.6D.5C.4N/A Architect of RecordWilliam Douglas HurleyWashington License No. 8855Unified Business ID No. 602 491 6682809 Ajax Avenue Suite 100Rogers Arkansas 72758Phone: 479.636.3545Fax: 479.636.1209••••5-A5.31CUSTOMER FRONTRESTROOM FLOOR PLAN3/8" = 1'-0"REMOVE ALL PLACARD SIGNAGE ASSOCIATEDWITH LIT SIGN RESTROOM NEEDS CLEANINGSWITCH.IF STROBES ARE LOCATED ABOVE THETILE LINE ON THE WALLS; STROBES ARETO BE ETR. IF STROBES FALL BELOWNEW TILE LINE, COORDINATE ALARMWORK ON SITE WITH WALMART GLOBALSECURITY TEAM FOR THE BOXES THATNEED TO BE MOVED.34"X48"MANEUVERINGSPACE15.02TYP30"x48" CLEARAND LEVELFLOOR SPACE24"x24" ACCESSPANEL IN CEILING2'-0" FROM WALL ANDIN FRONT OFLAVATORYREF 12-A5.24A5.2OH4A5.2SIM5'-0" DIAMETERTURNAROUNDN/A5-A5.3 5'-0" DIAMETERTURNAROUND34"X48"MANEUVERINGSPACE10.3510.11DRESSING10.3510.09TYP10.2660"x56" CLEARAND LEVEL FLOORSPACE30"x48" CLEARAND LEVELFLOOR SPACE,TYP.24"x24" ACCESSPANEL IN CEILING2'-0" FROM WALLAND IN FRONT OFLAVATORY. REF12-A5.210.104A5.14A5.111A5.211A5.210.11LIGHTEDTYP10.14TYP10.13TYP10.07TYP10.06TYP10.15TYP10.12TYP10.1215" MIN EA SIDE TYP 10.13TYP10.17WATER CLOSETS AND URINALS TO BERE-INSTALLED IN EXISTING LOCATIONS.VERIFY WATER CLOSETS IN ACCESSIBLELOCATIONS AND MATCH CLEARANCESSHOWN ON PLANS. IF LOCATION NEEDSTO BE ADJUSTED EXTEND WATERSUPPLY TO RELOCATED FLUSH VALVE.10.35CUSTOMERWOMEN112CUSTOMERMEN11110.3510.2610.1010.1710.14TYP10.06TYP10.1210.11DRESSING5'-0"3'-0"3'-0"3'-0" 1'-6"60"x56" CLEARAND LEVEL FLOORSPACE1'-6" 5'-0"3'-0"3'-0"3'-0" 1" 1"1'-3"1'-3"13'-1"3'-0"2'-6"2'-2"1'-0" 14'-11"2'-6"2'-2"1'-0"MUST MAINTAINTHESE DIMENSIONSALCOVE114ALCOVE1132'-0"KEYNOTES6.2748" HIGH WAINSCOT WITH OUTSIDE CORNERTRIM10.06TOILET PAPER HOLDER10.07SANITARY NAPKIN DISPOSAL10.09SOAP DISPENSER10.10DIAPER CHANGING TABLE10.11MIRROR10.12TOILET SEAT COVER DISPENSER10.13TOILET COMPARTMENTS(REF SPECS FOR TYPEAND HEIGHT)10.14GRAB BARS10.15URINAL SCREEN(REF SPECS FOR TYPE ANDHEIGHT) WITH FULL LENGTH ANGLE MOUNTINGBRACKETS10.26COAT HOOK (INSTALL PLYWOOD BACKING)10.35ELECTRIC HAND DRYER (RECESSED)15.02WALL MOUNTED LAVATORY, REF MECH10.17FREE STANDING TRASH RECEPTACLE, OWNERFURNISHEDCUSTOMERWOMEN166CUSTOMER MEN165HC15" MINEA SIDESIM5-A5.32REAR CUSTOMERRESTROOM FLOOR PLAN3/8"" = 1'-0"60"x56" CLEARAND LEVELFLOOR SPACE34"X48"MANEUVERINGSPACE5'-0" DIAMETERTURNAROUND4A5.2SIM.4A5.2OH10.09TYP11A5.24A5.1A5.211HC10.3510.12 TYP5-A5.310.11DRESSING10.13 TYP10.15TYP10.14TYP5'-0" DIAMETERTURNAROUNDHC24"x24" ACCESS PANEL INCEILING 2'-0" FROM WALLAND IN FRONT OF LAVATORYREF 12-A5.234"X48"MANEUVERINGSPACE10.3510.3510.1010.2610.11LIGHTEDTYPHC10.1710.2610.1010.354A5.130"x48" CLEARAND LEVELFLOOR SPACE,TYP.10.07 TYP10.06 TYP10.06TYP10.11DRESSINGREMOVE ALL PLACARD SIGNAGE ASSOCIATEDWITH LIT SIGN RESTROOM NEEDS CLEANINGSWITCH.IF STROBES ARE LOCATED ABOVE THETILE LINE ON THE WALLS; STROBES ARETO BE ETR. IF STROBES FALL BELOWNEW TILE LINE, COORDINATE ALARMWORK ON SITE WITH WALMART GLOBALSECURITY TEAM FOR THE BOXES THATNEED TO BE MOVED.WATER CLOSETS AND URINALS TO BERE-INSTALLED IN EXISTING LOCATIONS.VERIFY WATER CLOSETS IN ACCESSIBLELOCATIONS AND MATCH CLEARANCESSHOWN ON PLANS. IF LOCATION NEEDSTO BE ADJUSTED EXTEND WATERSUPPLY TO RELOCATED FLUSH VALVE.15.02TYP5'-0"3'-0"3'-0"3'-0"3'-0"2'-11"3'-0"1'-5"10.173'-7"2'-0"5'-6"1'-5"1'-3" 1'-3"3'-7"2'-2"2'-0"CONTINUOUS SEALANT TOMATCH LAVATORY DECKCOLOR10.09TYP10.11LIGHTEDTYP15.02TYP1'-6"30"x48" CLEARAND LEVELFLOOR SPACE,TYP.24"x24" ACCESS PANELIN CEILING 2'-0" FROMWALL AND IN FRONT OFLAVATORYREF 12-A5.25'-0"3'-0"3'-0"3'-0"3'-0"10.124'-10"4'-11"10.13TYPREMOVE AND REINSTALLIN EXISTING LOCATIONAFTER NEW WALL FINISHIS INSTALLED1'-6"1'-6"MUST MAINTAINTHIS DIMENSIONMUST MAINTAINTHIS DIMENSION10.121'-6"CONTINUOUS SEALANT TOMATCH LAVATORY DECKCOLOR2'-2"••••••••······ Architect of RecordWilliam Douglas HurleyWashington License No. 8855Unified Business ID No. 602 491 6682809 Ajax Avenue Suite 100Rogers Arkansas 72758Phone: 479.636.3545Fax: 479.636.1209COA5.210A5.29OH8A5.2TYPATWALL8A5.2TYPATWALLCUSTOMERWOMEN112CUSTOMERMEN111TYPCOCOCO6BA5.27TYP13A5.2TYP13A5.2A5.210A5.29OH8A5.2TYPATWALLCUSTOMERWOMEN166CUSTOMERMEN165TYPCOA5.27TYPTYP13A5.28A5.2TYPATWALLCOCOSIMTYPFLOOR TILEACCESSIBLESTALL34" DOOR28" DOORSTANDARDSTALLNAPKIN DISPOSALWHERE SHOWNON PLANGRAB BARNAPKIN DISPOSALWHERE SHOWNON PLAN18" VERTICALGRAB BARCOAT HOOK - INSTALL4" FROM EDGE OFDOOR 5'-6" AFF -TYPAT STANDARD STALLCOAT HOOK - INSTALLAT CENTER LINE OFDOOR 4'-0" AFFDOOR PULL -INSTALLED 34"-40" AFFTOILET PAPERDISPENSERTOILET SEATCOVER DISPENSERTOILET SEATCOVERDISPENSER5-A5.26-A5.2 REF PLANFLOOR FINISHREF PLANFINISH REF ELEVATIONS1 1/2" x 1 1/2" STAINLESS STEELCORNER GUARD MODIFIED IN FIELDBUTT TRANSITION TO TILEAT WALL. CONT SEALANTBETWEEN TRANSITION ANDTILE.TRANSITION STRIP.EXISTINGMETAL STUDSSTAINLESS STEEL TOP ANDCORNER TRIM-C REF SPEC 09310INSTALL SEALANT AT EDGEPORCELAIN TILE ON 1/4" CEMENTBACKER BOARD ON 1/2" PLYWOODTILE BASE7WALL END CAP3" = 1'-0"G15G15AT TILEAT CONCRETE OVERLAYMENTREF TO TOILET TILE ELEVATION ON SHEET A5.3 3"REF TO TOILET TILE ELEVATION ON SHEET A5.3 3"1/4" GYP BDPROVIDE 5/8" TYPEX GYP BD ATRATED CONDITIONS1/2" PLYWOOD(TYP)SOUNDBATTSWALL TILE1/4" CEMENT BD (TYP)PROVIDE 5/8" CEMENTBD AT RATEDCONDITIONSEXISTINGMETAL STUDS1/2" CEMENT BDIN LIEU OFPLYWOOD FORBOTTOM 6"BUILDING TAPE(4") REF SPECSECTION 09655TILE BASEFLOOR TILE1/4" GYP BDPROVIDE 5/8" TYPEX GYP BD ATRATED CONDITIONS1/2" PLYWOOD(TYP)SOUNDBATTSWALL TILE1/4" CEMENT BD (TYP)PROVIDE 5/8" CEMENTBD AT RATEDCONDITIONSEXISTINGMETAL STUDS1/2" CEMENT BDIN LIEU OFPLYWOOD FORBOTTOM 6"TILE BASEROLLED EPOXYPRIMER TO 3" AFFCONCRETEOVERLAYMENT1/8" GROUTJOINT (TYP)1/8" GROUTJOINT (TYP)SEALANTSTAINLESS STEELTOP AND CORNERTRIM-C REF SPEC093108ENLARGED WALL SECTION3" = 1'-0"WALL TILE REF FINISH PLANS1/4" CEMENT BOARDPROVIDE 5/8" CEMENT BDAT RATED CONDITIONS1/2" PLYWOOD1/8" GROUT JOINTEXISTINGMETAL STUDS9INSIDE CORNER SECTION3" = 1'-0"METAL STUDS3/8" STAINLESSSTEEL TOP ANDCORNER TRIM-CREF SPEC 09310SEALANTWALL TILEREF FINISHPLANSSEALANTTILE BASE1/2" PLYWOOD1/4" CEMENT BOARD10OUTSIDE CORNER DETAIL3" = 1'-0" Architect of RecordWilliam Douglas HurleyWashington License No. 8855Unified Business ID No. 602 491 6682809 Ajax Avenue Suite 100Rogers Arkansas 72758Phone: 479.636.3545Fax: 479.636.1209CUSTOMERMEN111CUSTOMERWOMEN112BCUSTOMERWOMEN166CUSTOMER MEN165H9FAMILY TOILET167MAX 3'-10" 1/4" CEMENT BOARD OVER 1/2" PLYWOOD BLOCKING 5'-0"5PAPERTOWEL/TRASH1 1/2" = 1'-0"NEW PLYWOOD BLOCKING,ATTACH TO NEAREST STUDSEA SIDENEW SURFACE-MOUNTEDPAPER TOWEL DISPENSEROWNER FURNISHED, GCINSTALLEDNEW "TRASH LOCATION" SIGNCENTERED ON PAPER TOWELDISPENSER. OWNERFURNISHED, GC INSTALLEDNEW FREE-STANDINGTRASH RECEPTACLEOWNER FURNISHEDCLMAX 3'-10" 1/4" CEMENT BOARD OVER 1/2" PLYWOOD BLOCKING 5'-0"6PAPERTOWEL/TRASH1 1/2" = 1'-0"NEW PLYWOOD BLOCKING, ATTACHTO NEAREST STUDS EA SIDENEW SURFACE-MOUNTEDPAPER TOWEL DISPENSEROWNER FURNISHED, GCINSTALLEDNEW SURFACE MOUNTEDTRASH RECEPTACLECENTERED ON PAPERTOWEL DISPENSER.OWNER FURNISHED, GCINSTALLEDCL6"21 TILES6"18 TILES6"17 TILES CT54G16CT53G15ACT54G16CT53G15ACT54G16CT53G15A7'-6"8'-0"9'-0"P131GYP BDP131GYP BDP131GYP BDTYPICAL ELEVATION ATCUSTOMER RESTROOMS WITH9'-0" CEILING HEIGHTTYPICAL ELEVATION ATCUSTOMER RESTROOMS WITH8'-0" CEILING HEIGHTTYPICAL ELEVATION ATCUSTOMER RESTROOMS WITH7'-6" CEILING HEIGHT4TOILET TILE ELEVATION1/4" = 1'-0" 24'-0" LARGE ITEM GM PICKUP 24'-0"LARGE ITEM GM PICKUP 24'-0"LARGE ITEM GM PICKUP 24'-0" LARGE ITEM GM PICKUP P1 3 P1 2 12345678910 A B C D E F G MEN WOMEN SALES WOMEN MEN FAMILY TOILET H J K 111213 B PRIOR TO STARTING DEMOLITION WORK, PLUG ALL FLOOR DRAINS AND/OR FLOOR SINKS WITH EXPANDABLE MECHANICAL PLUG (SIMILAR TO CHERNE ECON-O-GRIP). AFTER WORK IN THE RESTROOMS AREA IS COMPLETE, THOROUGHLY CLEAN ALL DEBRIS FROM FLOOR DRAIN AND/OR FLOOR SINK GRATES AND BODIES. CAMERA SCOPE FROM LOCATION OF WORK THROUGH SANITARY MAINS TO THE MANHOLE OUTSIDE THE BUILDING. IF SANITARY LINES HAVE ANY OBSTRUCTIONS, HYDRO JET LINES AS NEEDED TO CLEAR OBSTRUCTIONS. REPLACE MULTI-STATION LAVATORY (TYP OF 2). PROVIDE BRANCH WASTE AND VENT PIPING IN WALL AS REQUIRED FOR INDIVIDUAL P-TRAPS AT EACH BASIN TYP ALL RESTROOMS. WOMEN MEN EXISTING UR TYP OF 2. EXISTING WC TYP OF 6. REPLACE FD FD4SS 15.429 4 P1 (TYP OF 2) L16L16 15.406 FD4SS 15.429 DEMO HB 15.405 EXISTING WCO 15.448 TYP OF 2 REPLACE FD 15.448 15.448 RESET FCO TO NEW FINISH FLOOR LEVEL 15.429 9 PRIOR TO STARTING DEMOLITION WORK, PLUG ALL FLOOR DRAINS AND/OR FLOOR SINKS WITH EXPANDABLE MECHANICAL PLUG (SIMILAR TO CHERNE ECON-O-GRIP). AFTER WORK IN THE RESTROOMS AREA IS COMPLETE, THOROUGHLY CLEAN ALL DEBRIS FROM FLOOR DRAIN AND/OR FLOOR SINK GRATES AND BODIES. CAMERA SCOPE FROM LOCATION OF WORK THROUGH SANITARY MAINS TO THE MANHOLE OUTSIDE THE BUILDING. IF SANITARY LINES HAVE ANY OBSTRUCTIONS, HYDRO JET LINES AS NEEDED TO CLEAR OBSTRUCTIONS. REPLACE MULTI-STATION LAVATORY (TYP OF 4). PROVIDE BRANCH WASTE AND VENT PIPING IN WALL AS REQUIRED FOR INDIVIDUAL P-TRAPS AT EACH BASIN TYP ALL RESTROOMS. EXISTING WC TYP OF 8 FAMILY TOILET 4 P1 (TYP OF 3) REPLACE FD WOMEN MEN EXISTING UR TYP OF 3 H FD4SS 15.429 L16 L16 15.406 REPLACE LAVATORY. PROVIDE BRANCH WASTE AND VENT PIPING IN WALL AS REQUIRED FOR INDIVIDUAL P-TRAPS. 15.448 15.448 REPLACE FD REPLACE FD REMOVE HB 15.405 TYP OF 2 EXISTING WCO 15.448 15.406 L16 L16 FD4SS FD4SS 15.429 15.429 L22 TYP OF 2 DEMO LAV EXTEND EXISTING PIPING THRU WALL TO NEW LAV EXISTING EWC 15.448 SPECIALTY PLUMBING FIXTURE SCHEDULE MARK FIXTURE MANUFACTURER MODEL FIXTURE DESCRIPTION WPG WATER PRESSURE GAUGE AMETEK TRERICE WEISS INSTRUMENTS 656 D83LFSS LF252 2.5 INCH STAINLESS STEEL CASE, ALL WETTED PARTS STAINLESS STEEL, LIQUID FILLED, 1/4 INCH NPT CONNECTOR, 1.6% ACCURACY, 30" HG VAC TO 100 PSI RANGE. WHA WATER HAMMER ARRESTOR JOSAM PRECISION PLUMBING PRODUCTS WATTS WILKINS JAY R. SMITH SIOUX CHIEF MIFAB SERIES 75000 STAINLESS STEEL #316 SERIES SS SERIES MODEL 1250XL SERIES HYDROTROLS HYDRA-RESTER MWH LEAD FREE CONFORM TO PDI WH-201, ANSI A112.26.1M, ASSE 1010. FCV30 FLOW CONTROL VALVE BELL & GOSSETT FLOW DESIGN # CB LF "CIRCUIT SETTER PLUS" ICSS050 LEAD FREE NAMEPLATE AND 1/2" VALVE BODY SIZE UNLESS SHOWN OTHERWISE ON PLANS. SET AND BALANCE TO 0.25 GPM OR PROVIDE 0.25 GPM CARTRIDGE UNLESS SHOWN OTHERWISE ON PLANS AND PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. DCV DOUBLE-CHECK VALVE BACKFLOW PREVENTER (STAINLESS STEEL) WATTS SS007QT-S ASSE 1015, 316 STAINLESS STEEL BODY, QUARTER TURN TEST COCKS, QUARTER TURN, FULL PORT BALL VALVES AND STAINLESS STEEL STRAINER. ---CHECK VALVES RED-WHITE APOLLO CRANE WATTS NIBCO 232 SERIES 61-100 119J 6 T-413 BRASS JACKET WITH PLASTIC VALVE ASSEMBLY ---DOUBLE-CHECK VALVE BACKFLOW PREVENTER WATTS BEECO FEBCO WILKINS LF007QT OR LF709 FDC-LF LF850 350XL OR 950XLT2 LEAD FREE, INCLUDE TWO INDEPENDENT-ACTING CHECK VALVES, TWO SHUT-OFF VAVLES AND REQUIRED MEANS FOR TESTING FOR EACH ASSEMBLY. MINIMUM 175 PSI WORKING PRESSURE. ---LOCKABLE SHUT OFF VALVES RED-WHITE APOLLO CRANE WATTS 5042 SERIES 70LF-100 LF-T-255 LFB-6000 OR LFB-6001 BRASS BALL VALVES WITH PLASTIC JACKETED LEVER TYPE HANDLE. ---REDUCED PRESSURE BACKFLOW PREVENTER WATTS BEECO FEBCO WILKINS LF009QT OR LF909 FRP-LF LF860 375XL OR 975XL LEAD FREE, PROVIDE STRAINER, SHUT-OFF VALVES AND TEST COCKS: INSTALL DRAIN LINE WITH AIR GAP ASSEMBLY TO RECEPTOR APPROVED BY AUTHORITY HAVING JURISDICTION. MINIMUM 175 PSI WORKING PRESSURE. ---STRAINER WATTS APOLLO LF777SI 59-004-06 CAST BRONZE Y-STRAINER WITH BALL VALVE ---TRAP PRIMER (MULTIPLE TRAPS) PRECISION PLUMBING PRODUCTS MIFAB JOSAM SIOUX CHIEF PRIME RITE OR OREGON #1 M-500-NPB 88300 SERIES 695 LEAD FREE, PROVIDE ALL BRONZE PRIMER VALVE WTIH REMOVABLE OPERATING PARTS, INTEGRAL VACUUM BREAKER, GASKETED ACCESS COVER, AND MULTIPLE TRAP CAPABILITY ---TRAP PRIMER (SINGLE TRAP) PRECISION PLUMBING PRODUCTS SIOUX CHIEF PRIME-RITE OR OREGON #1 695 LEAD FREE, PROVIDE ALL BRONZE PRIMER VALVE WITH REMOVABLE OPERATING PARTS, INTEGRAL VACUUM BREAKER, AND GASKETED ACCESS COVER. ---VACUUM RELIEF VALVE WATTS LFN36-M1 LEAD FREE BRASS BODY. CSA/ANSI Z21.22 ---VALVES RED-WHITE APOLLO CRANE WATTS NIBCO 5044AB OR 5049AB SERIES 70 LF LF9210 SERIES LFFBV-3C OR LFFBVS-3C FP-600-A-LF LEAD FREE FULL PORT BRASS BALL VALVE WITH PLASTIC JACKETED LEVER TYPE HANDLE. GENERAL INFORMATION: 1. THIS SCHEDULE IS COMPREHENSIVE. ALL MARKS MAY OR MAY NOT BE USED. ---REDUCED PRESSURE BACKFLOW PREVENTER (STAINLESS STEEL) WATTS SS009M3QT-S LEAD FREE, STAINLESS STEEL REDUCED PRESSURE ZONE ASSEMBLY. FURNISHED WITH STAINLESS STEEL STRAINER, VANDAL RESISTANT TEST COCKS, AND FULL PORT QUARTER TURN BALL VALVE SHUTOFFS. INSTALL DRAIN LINE WITH AIR GAP ASSEMBLY TO RECEPTOR APPROVED BY AUTHORITY HAVING JURISDICTION. MINIMUM 175 PSI WORKING PRESSURE. SET TOP OF DRAIN TO BE FLUSH WITH FINISH CONCRETE OVERLAY. COORDINATE FINISH ELEVATION WITH GENERAL CONTRACTOR. LOCATE FLOOR DRAIN WHERE SHOWN ON DIMENSIONED PLUMBING FLOOR PLAN. FLOOR DEEP-SEAL P-TRAP FLOOR DRAIN BODY WITH 3" OUTLET (CAULK OR PUSH-ON), MEMBRANE CLAMPING COLLAR SQUARE TOP FLOOR DRAIN DO NOT SLOPE FLOOR TO DRAIN NOTE: THIS DETAIL APPLIES ONLY TO KEYNOTED RESTROOM FLOOR DRAINS AND SHALL NOT BE USED FOR DRAINS AND CLEANOUTS ON THE SALES FLOOR. CONCRETE OVERLAY (TILE WHERE INDICATED ON ARCHITECTURAL FLOOR FINISH PLAN) NOTE: IF EXIST FLOOR SLOPES TO DRAIN, COORDINATE WITH ARCHITECTURAL FOR FLOOR DRAIN TO BE FLUSH WITH FINISH FLOOR.engineering consultants3333 East Battlefield Road, Suite 1000 | Springfield, MO 65804T: 417.881.0020 : www.rtmec.comSHEET: DRAWN BY: CHECKED BY: PROTO CYCLE: DOCUMENT DATE:CONSULTANTSSTIPULATION FOR REUSEPROTO:JOB NUMBER:THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND MAY NOT REFLECT EXACT "AS-BUILT" CONDITIONS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OF PERFORMING THE WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. RR SPECIAL PROJECT P1 PLUMBING PLANS DETAILS AND SCHEDULES AGBYELM, WASHINGTON2021.0925YELM, WASHINGTON10-18-2110-18-21STORE NO: 3705-24017809242117100 STATE ROUTE 507 SEJEE KEYNOTES 15.405 PROPERLY CAP, PLUG AND CONCEAL ANY PIPING LEFT IN PLACE. CAP ABANDONED SEWER PIPING A MINIMUM OF 8" BELOW FINISHED FLOOR. MATCH EXISTING FLOOR CONSTRUCTION AND FINISHES. RE: ARCHITECTURAL PLANS. REMOVE UNUSED WATER AND VENT PIPING ABOVE CEILING AND CAP REMAINING PIPE. 15.406 PLUMBING CONTRACTOR TO MAKE ALL NECESSARY DISCONNECTS AND RECONNECTS OF PLUMBING FIXTURES BEING RELOCATED OR NEW. 15.429 CUT AND PATCH EXISTING CONCRETE FLOOR SLAB FOR INSTALLATION OF NEW UNDERGROUND PLUMBING PIPE. MATCH EXISTING CONSTRUCTION AND FINISHES. 15.448 PLUMBING CONTRACTOR TO MAKE ALL NECESSARY DISCONNECTS AND RECONNECTS OF PLUMBING FIXTURES FOR FINISHES WORK. PROVIDE CONTINUOUS SEALANT ALONG THE EDGES OF RECONNECTED FIXTURES. REFURBISH URINAL AND WC FLUSH VALVES TO LIKE NEW OPERATING CONDITION. 1" = 60'-0" 1 PLUMBING KEY PLAN 1/8" = 1'-0" 2 FRONT RESTROOM PLUMBING PLAN 1/8" = 1'-0" 3 REAR RESTROOM PLUMBING PLAN GENERAL NOTES 12.20.13 1. GENERAL NOTES ARE APPLICABLE TO ALL PLUMBING DRAWINGS. 2. PROVIDE ALL MATERIALS FOR A COMPLETE INSTALLATION IN ALL RESPECTS AND READY FOR INTENDED USE AND IN STRICT ACCORDANCE WITH STATE AND LOCAL CODES AND MANUFACTURERS RECOMMENDATIONS. 3. STORE MUST BE KEPT IN OPERATION. ARRANGE ALL WORK TO KEEP DISRUPTIONS TO STORE OPERATIONS TO A MINIMUM. COORDINATE WITH EXISTING AND NEW CONSTRUCTION. PAY ALL NECESSARY FEES AND PERMITS. 4. IF NEW CONSTRUCTION DISRUPTS EXISTING UNDERGROUND SERVICES (GAS, SEWER, DOMESTIC WATER, FIRE SPRINKLER, ETC.), PROVIDE ALL MATERIALS AND LABOR AS REQUIRED TO MAINTAIN THEIR PROPER OPERATION. 5. CONTRACTOR IS RESPONSIBLE FOR UTILIZING OWNER APPROVED ROOFING CONTRACTORS FOR CUTTING AND PATCHING ROOF. 6. EXISTING PIPE SIZES AND LOCATIONS HAVE NOT BEEN FIELD VERIFIED. CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY LOCATION AND SIZES OF ALL EXISTING PIPING THAT IS BEING CONNECTED TO OR MODIFIED, AND TO VERIFY THAT PROPER SLOPES AND ELEVATIONS ARE AVAILABLE. MAINTAIN MINIMUM SLOPE OF 1/8" PER FOOT FOR SAN SEWER PIPING 3" OR LARGER. MAINTAIN MINIMUM SLOPE OF 1/4" PER FOOT FOR SAN SEWER PIPING SMALLER THAN 3". REF ARCH. FOR TRENCHING REQUIREMENTS. 7. PLUMBING CONTRACTOR SHALL VERIFY EXISTING SEWER AND VENT PIPE SIZE AND ELEVATION AND SHALL VERIFY THAT PROPER SLOPES ARE AVAILABLE BEFORE CUTTING FLOOR SLAB FOR NEW SEWER PIPING. 8. PROVIDE ACCESS DOORS TO NEW WATER VALVES AND CLEANOUTS AS NECESSARY WHEN INSTALLED IN INACCESSIBLE AREAS. 9. PLUMBING CONTRACTOR SHALL PROVIDE ONE YEAR WARRANTY FOR PROPER SEWER SYSTEM OPERATION. 10. SANITARY DRAINAGE LINES AND FITTINGS (DRAIN, WASTE AND VENT) SHALL BE CAST IRON, COATED INSIDE AND OUTSIDE. WHERE PERMITTED BY LOCAL CODES, PVC-DWV PLASTIC SCHEDULE 40 MAY BE USED IN LIEU OF CAST IRON. ALL PHOTOLAB PLUMBING SHALL BE PVC. 11. WATER PIPING ABOVE GRADE SHALL BE TYPE "L" HARD DRAWN COPPER JOINED WITH WROUGHT COPPER FITTINGS. MAKE JOINTS USING LEAD-FREE SOLDER AND A NON-CORROSIVE, PASTE-TYPE FLUX. MAKE PIPING CONNECTIONS TO A FIXTURE WITH CHROME-PLATED SEAMLESS BRASS TUBE. INSULATE HOT & COLD WATER PIPING WITH RIGID GLASS FIBER A MINIMUM OF 1/2" THICK WITH WHITE ALL-SERVICE JACKET (VAPOR RETARDER). 12. PROVIDE AUTOMATIC TRAP PRIMERS ON FLOOR DRAINS IF REQUIRED BY LOCAL PLUMBING CODES. 13. ALL FLOOR CLEANOUTS SHALL BE INSTALLED FLUSH WITH FLOOR FINISH MATERIAL OR FLUSH WITH CONCRETE SLAB IF NO FLOOR FINISH MATERIAL IS CALLED OUT FOR ON ARCHITECTURAL DRAWINGS. 14. LOCATE ALL FLOOR CLEAN-OUTS OUT OF TRAFFIC WAYS, WHILE MAINTAINING ACCESSIBILITY. LOCATE PER DIMENSIONS IF SHOWN ON PLANS. 15. FLOOR CUTS SHALL BE STRAIGHT AND CLEAN, REPLACE REMOVED SLAB WITH CONCRETE FLUSH AND SMOOTH WITH ADJACENT FLOOR SLAB. REFERENCE ARCHITECTURAL SHEETS. COORDINATE WITH GENERAL CONTRACTOR. 16. CAP ALL PIPING OPENINGS DURING CONSTRUCTION UNTIL FINAL CONNECTIONS TO EQUIPMENT AND ACCESSORIES ARE MADE. 17. CUT AND PATCH EXISTING CONCRETE FLOOR SLAB FOR INSTALLATION OF NEW UNDERGROUND PLUMBING PIPE. MATCH EXISTING CONSTRUCTION. 18. DO NOT INSTALL PIPING WITHIN COOLER PANELS. INSTALL EXPOSED PIPING IN PREP AREAS A MINIMUM OF 1" FROM PANEL WALL AND 6" ABOVE FINISHED FLOOR TO ALLOW FOR CLEANING. USE ONLY NON- CORROSIVE MATERIALS FOR SPACERS AND ANCHORS. 19. PROVIDE ESCUTCHEON PLATES FOR PLUMBING PENETRATIONS THROUGH GROCERY CEILINGS AND WALLS. 20. PROVIDE AIR TIGHT SEAL AROUND PIPING PENETRATIONS THROUGH COOLER/FREEZER WALLS AND CEILINGS. FINISH WITH ESCUTCHEON PLATE. 21. PROVIDE HEAT TAPE AND INSULATION ON ALL WATER AND DRAIN PIPING EXPOSED TO FREEZING. 22. INSTALL CONTINUOUS SEALANT JOINT AT ALL EXTERIOR WALL PENETRATIONS. 23. AT CONTRACTOR'S OPTION (U.N.O), IN LIEU OF COPPER WATER PIPING, PEX OR AQUATHERM PIPING MAY BE USED. REFER TO EQUIVALENT NOMINAL PIPE SIZES SCHEDULE AND SPECIFICATIONS. 24. PROVIDE SEISMIC BRACING BASED ON APPROPRIATE SEISMIC ZONE REQUIREMENTS PER SMACNA PUBLISHED SEISMIC DETAILS, LOCAL AND NATIONAL CODES. CONTRACTOR'S RESPONSIBILITY INCLUDES STRUCTURAL ENGINEER'S CERTIFICATION ON DETAILS SUBMITTED FOR PERMITTING. 25. BUILDING COMPONENTS ABANDONED BY THE SCOPE OF WORK SHALL BE SECURED TO PREVENT FALLING, LOOSENING, OR CREATING DAMAGE OF ANY KIND IN THE FUTURE. PLUMBING SYMBOLS WALL CLEANOUT HOSE BIBB FREEZE PROOF WALL HYDRANT YARD CLEANOUT FLOOR SINK ROOF DRAIN/OVERFLOW ROOF DRAIN FLOOR DRAIN T & P RELIEF VALVE WATER HAMMER ARRESTOR BACKFLOW PREVENTER SHUT-OFF VALVE IN VERTICAL LINE CHECK VALVE PLUG VALVE BALL VALVE TEE - TURNED UP TEE - TURNED DOWN ELBOW - TURNED UP ELBOW - TURNED DOWN COMPRESSED AIR NATURAL GAS DOMESTIC HOT WATER DOMESTIC HOT WATER RETURN DOMESTIC COLD WATER OVERFLOW ROOF DRAIN LINE ROOF DRAIN LINE OIL WASTE GREASE WASTE SANITARY SEWER TEPID OR TEMPERED WATER WATER METER FILTERED WATER STORM SEWER IRRIGATION WATER THERMOSTATIC MIXING VALVE GAS COCK GAS PRESSURE REGULATOR PLUMBING VENT REVERSE OSMOSIS WATER CONDENSATE DRAIN CONNECT TO EXISTING EXISTING TO REMAIN PLUMBING VACUUM DEMO PIPE AREA OF SLAB CUT FLOW CONTROL VALVE THERMOMETER SS GW OW ST RD ORD IW T UNION F G A CD RO V VAC M WHA TMV FD FS YCO FPWH HB WCO ETR RD VENT BELOW FLOORVBF FLOOR CLEANOUTFCO PLAN SIZE 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 2 1/2" 3" 4" NOTE: REFER TO SPECIFICATIONS FOR APPROVED MANUFACTURERS. EQUIVALENT NOMINAL PIPE SIZES HOT WATER 1/2" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 3 1/2" 6" 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 2 1/2" 3" 4" PEX 1/2" 1" 1 1/4" 1 1/2" 2" N/A N/A N/A N/A (COPPER)COLD WATER POLYPROPYLENE NTS4OPEN FLOOR AREA DRAIN GENERAL INFORMATION (AS APPLICABLE): 1. REFER TO PLANS FOR DRAIN OUTLET SIZE. 2. LOAD CLASSIFICATIONS: LIGHT DUTY <2000 LBS, MEDIUM DUTY 2000 TO 4999 LBS, HEAVY DUTY 5000 TO 7499 LBS, EXTRA HEAVY DUTY 7500 TO 9999 LBS. FLOOR DRAIN SCHEDULE MARK MANUFACTURER MODEL DESCRIPTION FD4SS JOSAM 41330 STAINLESS STEEL FLOOR DRAIN, 6" X 6" SQUARE TOP, SECURED GRATE GENERAL INFORMATION (ALL FIXTURES): 1. SUBSTITUTIONS NOT PERMITTED. REF SPECIFICATIONS FOR APPROVED MANUFACTURERS OF THE FOLLOWING TRIM AND ACCESSORIES: -P-TRAP WITH CLEANOUT PLUG AND SINK CONTINUOUS WASTES: POLISHED CHROME-PLATED TUBULAR BRASS, 17 GAUGE WITH BRASS NUTS AND SLIP INSERTS. -SS BRAIDED WATER SUPPLY: FLEXIBLE BRAIDED STAINLESS STEEL (SS) OUTER SHEATHING WITH REINFORCED PVC INNER TUBING. -STOP VALVES: CHROME PLATED BRASS, QUARTER TURN ANGLE STOP VALVES. NOTES: A. INSTALL FURNISHED 1/2" X 3 3/4" STAINLESS STEEL SIMPSON WEDGE-ALL WEDGE ANCHORS FOR ALL FlOOR MOUNTED FIXTURE CARRIERS. B. INSTALL FURNISHED THERMOSTATIC MIXING VALVE. C. REFERENCE ARCHITECTURAL DRAWINGS FOR EWC2 ORIENTATION. D. COORDINATE WATER ROUGH-IN HEIGHT FROM MANUFACTURER'S INSTALLATION INSTRUCTIONS WITH GRAB BAR LOCATION. REF ARCH. E. USE SAME MANUFACTURER FOR UR1 AND UR2. F. CONTRACTOR TO FURNISH AND INSTALL LAVATORY DECK ASSEMBLY FIXTURE AND TRIM SUPPLIED BY HAINES, JONES & CADBURY (HJC). REF SPECIFICATIONS. TOILET PLUMBING FIXTURE SCHEDULE MARK FIXTURE BRANCH SIZES (MIN) MANUFACTURER MODEL TRIM AND ACCESSORIES NOTESCW HW WASTE VENT L16 LAVATORY DECK 3-STATION TEMPERED 1/2" 1 1/2" 1 1/2" VERONA STONE AND STEEL SMQ0046-3SCN S2D-UM7300-90-SB VERONA: WALL MOUNTED, ONE-PIECE QUARTZIA DECK (BIANCO SAND) STONE AND STEEL: WALL MOUNTED, ONE-PIECE QUARTZ DECK (SNOW BLIND) BOWL: CHINA SHELL CH-6360 UNDERMOUNT 18"x13" CHINA BOWL(S) VERONA BASE: ACORN EN1121A0-002 ENVIRO-GLAZED WHITE ENCLOSURE. STONE & STEEL BASE: S2D-ENC7000-WH WHITE ENCLOSURE. FAUCET: TOTO TEL145-D10E - 0.5 GPM SENSOR OPERATED SELF-GENERATING POWER SYSTEM. CHROME PLATED BRASS P-TRAP WITH CLEANOUT, GRID STRAINER WITH TAILPIECE. CONNECTION ACCESSORIES: (1) STOP VALVE, (1) 3/8" x 1/2" SS BRAIDED WATER SUPPLY PER FAUCET; TMV NOT REQUIRED. F L22 LAVATORY DECK 1-STATION TEMPERED 1/2" 1 1/2" 1 1/2" VERONA STONE AND STEEL SMQ0046-1S S2D-UM7100-30-SB VERONA: WALL MOUNTED, ONE-PIECE QUARTZIA DECK (BIANCO SAND) STONE AND STEEL: WALL MOUNTED, ONE-PIECE QUARTZ DECK (SNOW BLIND) BOWL: CHINA SHELL CH-6360 UNDERMOUNT 18"x13" CHINA BOWL(S) VERONA BASE: ACORN EN1121A0-002 ENVIRO-GLAZED WHITE ENCLOSURE. STONE & STEEL BASE: S2D-ENC7000-WH WHITE ENCLOSURE. FAUCET: TOTO TEL145-D10E - 0.5 GPM SENSOR OPERATED SELF-GENERATING POWER SYSTEM. CHROME PLATED BRASS P-TRAP WITH CLEANOUT, GRID STRAINER WITH TAILPIECE. CONNECTION ACCESSORIES: (1) STOP VALVE, (1) 3/8" x 1/2" SS BRAIDED WATER SUPPLY PER FAUCET; TMV NOT REQUIRED. F ISSUE BLOCK D D R ROS OS D D DR R R D D 24'-0" LARGE ITEM GM PICKUP 24'-0"LARGE ITEM GM PICKUP 24'-0"LARGE ITEM GM PICKUP 24'-0" LARGE ITEM GM PICKUP B TYP 16.125 PROVIDE STAINLESS STEEL COVER PLATES TYP IN RESTROOMS.16.129 TO SCENT SYSTEM RECEPTACLE CIRCUIT, TYP OF 2. REF: 1/E2. BACKLIT MIRROR, TYP. 16.147 WOMEN MEN NL NL NL NL NL NL 16.147 H2P:24 TYP 68R 2' - 0"4' - 7"1' - 6"4' - 0"2' - 3"5' - 0"5' - 0"5' - 0"3' - 3"3' - 9"4' - 3"4' - 10"4' - 4"3' - 0"2' - 11"3' - 0"4' - 4"3' - 0"2' - 10"3' - 0"2' - 3"5' - 0"5' - 0"4' - 3"3' - 10"3' - 2"5' - 0"4' - 3" TYP 68R COORDINATE RESTROOM LIGHT FIXTURE LOCATIONS WITH CEILING STRUCTURE, DUCTWORK DIFFUSERS, SPRINKLERS AND GC. LIGHTING LAYOUT ADJUSTMENTS SHALL BE KEPT TO A MINIMUM. MAINTAIN LAYOUT AS CLOSELY AS POSSIBLE. FURNISH AND INSTALL SENSORSWITCH CMR9 CEILING MOUNTED OCCUPANCY SENSOR, (SET FOR MAXIMUM TIME DELAY) TYP OF 2 9 MEN FAMILY TOILET OS ETR OS ETR TYP 16.125 H WOMEN OS ETR TYP 16.126 TYP 16.126 9 OS ETR OS ETR OS ETR TYP 16.125 FAMILY TOILET TYP 16.125 MEN WOMEN BACKLIT MIRROR, TYP. TO SCENT SYSTEM RECEPTACLE CIRCUIT, TYP OF 3. REF: 2/E2. PROVIDE STAINLESS STEEL COVER PLATES TYP IN RESTROOMS AND FAMILY TOILET H NL NL NL NL NL TYP H1P1:18 16.129 16.147 2' - 8"4' - 0"3' - 7"2' - 11"5' - 6"2' - 9"5' - 4"2' - 6"5' - 0"5' - 0"5' - 0"4' - 4"4' - 4"5' - 0"7' - 10"8' - 3"4' - 0"2' - 6"5' - 0"5' - 0"5' - 0"5' - 0"4' - 4"4' - 4" 4' - 0"2' - 11"3' - 0"3' - 1"5' - 0"5' - 0" 4' - 0"3' - 0"3' - 0"3' - 2"5' - 0"5' - 0" COORDINATE RESTROOM LIGHT FIXTURE LOCATIONS WITH CEILING STRUCTURE, DUCTWORK DIFFUSERS, SPRINKLERS AND GC. LIGHTING LAYOUT ADJUSTMENTS SHALL BE KEPT TO A MINIMUM. MAINTAIN LAYOUT AS CLOSELY AS POSSIBLE. TYP 68R TYP 68R NL NL E2 3 E2 1 E2 2 12345678910 A B C D E F G E1 2 E1 3 E1 4 E1 5 EDC #1 FAMILY TOILET MEN MEN WOMEN SALES H J E2 4 EDC #2 K WOMEN 111213 B MENWOMEN TYP 16.125 TYP 16.126 TYP 16.126 TYP 16.126 engineering consultants3333 East Battlefield Road, Suite 1000 | Springfield, MO 65804T: 417.881.0020 : www.rtmec.comSHEET: DRAWN BY: CHECKED BY: PROTO CYCLE: DOCUMENT DATE:CONSULTANTSSTIPULATION FOR REUSEPROTO:JOB NUMBER:THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND MAY NOT REFLECT EXACT "AS-BUILT" CONDITIONS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OF PERFORMING THE WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. RR SPECIAL PROJECT E1 ELECTRICAL PLANS AGBYELM, WASHINGTON2021.0925YELM, WASHINGTON10-18-2110-18-21STORE NO: 3705-24017809242117100 STATE ROUTE 507 SEJEE KEYNOTES 16.125 EXISTING LIGHT FIXTURES TO REMAIN UNLESS NOTED OTHERWISE. 16.126 EXISTING LIGHT FIXTURE TO BE DEMOLISHED. 16.129 CONNECT TO EXISTING CIRCUIT PREVIOUSLY SERVING AREA LIGHTING THAT WAS REMOVED. MAINTAIN EXISTING CIRCUIT CONTROL UNLESS NOTED OTHERWISE. PROVIDE CONSTANT HOT FOR EMERGENCY EXIT AND LOCALLY CONTROLLED LIGHT FIXTURES. 16.147 BACKLIT MIRROR 120V/12V LED DRIVER AND RELAY (RIB2402D 277V COIL) INSTALLED ABOVE CEILING. LED DRIVER FURNISHED BY OTHERS, INSTALLED BY EC. RELAY, WIRING AND ALL FINAL CONNECTIONS FURNISHED AND INSTALLED BY EC. ROUTE 120V LED DRIVER CIRCUIT THROUGH RELAY. RELAY COIL SHALL BE CONTROLLED BY EXISTING 277V LIGHTING CONTROL. COORDINATE EXACT LOCATION OF CEILING ACCESS PANEL WITH GC AS REQUIRED. EXISTING LIGHTING FIXTURES NOT SHOWN ARE EXISTING TO REMAIN AND ARE NOT AFFECTED BY THE SCOPE OF WORK ON THIS PROJECT. THIS INCLUDES ALL GENERAL LIGHTING, EGRESS LIGHTING AND EXIT LIGHTING. 1/4" = 1'-0" 3 FRONT RESTROOM LIGHTING PLAN 1/8" = 1'-0" 4 REAR RESTROOM LIGHTING DEMO PLAN 1/4" = 1'-0" 5 REAR RESTROOM LIGHTING PLAN 1" = 60'-0" 1 ELECTRICAL KEY PLAN 1/8" = 1'-0" 2 FRONT RESTROOM LIGHTING DEMO PLAN ISSUE BLOCK JJ JJ J J J J J BAS BOARD PHONE BOARD F/A BOARD J MSWBL1D1 H1P1 LFL1D2 H1A H1B L1U-1 EDC #1 11 H1P2 6 B PROVIDE STAINLESS STEEL COVER PLATES TYP IN RESTROOMS. WOMEN MEN 16.400 16.400A TO BACKLIT MIRROR RELAY, TYP OF 2. REF: 3/E1. 16.462 HDHD HD L2D2:31 L2D2:33 16.145 L2D2-26 (20A/1P) #8W L2D2:28 TYP OF 2 16.409 16.409 16.408 ETR (20A/1P) #8W 16.408 HD L2D2:39 16.131 16.477 16.477 16.462 16.145 9 HD HD HD (20A/1P) #8W WOMEN MEN FAMILY TOILET PROVIDE STAINLESS STEEL COVER PLATES TYP IN RESTROOMS TO BACKLIT MIRROR RELAY. TYP OF 3. REF 5/E1. H L1D1:21 HD (20A/1P) #8W TYP OF 3 ETR 16.400 16.400A 16.131 16.409 16.408 16.408 16.409 L1D1:29 L1D1:31 16.145 16.145 16.462 16.462 16.477 16.477 L1D2-15 L1D1:17 HD 16.409 16.145 L1D1:27 16.462 9 B EDC #2 L2B H2B H2A L2U L2D1/L2D2 (STACKED) L2D3 H2P L2P engineering consultants3333 East Battlefield Road, Suite 1000 | Springfield, MO 65804T: 417.881.0020 : www.rtmec.comSHEET: DRAWN BY: CHECKED BY: PROTO CYCLE: DOCUMENT DATE:CONSULTANTSSTIPULATION FOR REUSEPROTO:JOB NUMBER:THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND MAY NOT REFLECT EXACT "AS-BUILT" CONDITIONS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OF PERFORMING THE WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. RR SPECIAL PROJECT E2 ELECTRICAL PLANS DETAILS AND SCHEDULES AGBYELM, WASHINGTON2021.0925YELM, WASHINGTON10-18-2110-18-21STORE NO: 3705-24017809242117100 STATE ROUTE 507 SEJEE 1/8" = 1'-0" 3 EDC #1 POWER PLAN 1. FURNISH AND INSTALL ALL MATERIALS, EQUIPMENT, AND LABOR, FOR A COMPLETE INSTALLATION IN ALL RESPECTS, READY FOR INTENDED USE AND IN STRICT ACCORDANCE WITH NEC, NESC, STATE, AND LOCAL CODES, AND MANUFACTURER'S RECOMMENDATIONS. PAY ALL NECESSARY FEES AND PERMITS. A. NO CIRCUITRY SHALL BE ALLOWED TO BE ROUTED ACROSS THE ROOF OR THE EXTERIOR SIDE OF THE EXTERIOR WALLS. B. ALL EQUIPMENT SHALL BE UL LISTED WHERE APPLICABLE. C. ARRANGE ALL WORK TO MINIMIZE DISRUPTIONS TO STORE OPERATIONS. COORDINATE ALL DISRUPTIONS WITH WALMART CONSTRUCTION MANAGER AND STORE MANAGER. D. CONTRACTOR SHALL VERIFY ALL WALL FINISH THICKNESS BEFORE INSTALLING BOXES. FURNISH AND INSTALL EXTENDED BOXES OR BOX EXTENDERS WHERE REQUIRED. E. CONTRACTOR SHALL VERIFY THAT ALL AFFECTED PANELBOARDS HAVE CIRCUIT BREAKER KNOCKOUTS PROPERLY COVERED ANDTHAT ALL TRIM IS IN GOOD CONDITION, ALLOWING NO ACCESS TO LIVE PARTS. 2. PROVIDE SEALS AT RACEWAY PENETRATIONS AS FOLLOWS: A. FIRE RATED WALLS: SEAL PER SPECIFICATIONS FOR FIRE STOPPING. B. NEUTRALIZATION AREA: SEAL PER MECHANICAL DETAIL. C. FREEZER/COOLER BOXES: SEAL WITH EXPANDING FOAM SEALANT. D. EXTERIOR: REFER TO ARCHITECTURAL DOCUMENTS FOR SEALING REQUIREMENTS AT ALL EXTERIOR MOUNTED DEVICES, FIXTURES, ENCLOSURES, AND RACEWAY PENETRATIONS. 3. PROVIDE A SEPARATE EQUIPMENT GROUNDING CONDUCTOR (SIZE PER NEC) IN PVC TYPE CONDUIT, POWER AND LIGHTING CIRCUITS, ISOLATED GROUND CIRCUITS, OR AS SHOWN ON PLANS. CONDUIT SHALL BE SIZED PER NEC BASED ON THWN 600 VOLT COPPER SINGLE CONDUCTORS, PLUS THE EQUIPMENT GROUNDING CONDUCTOR. 4. WIRING DEVICES: DEVICE MOUNTING HEIGHTS ARE FROM FINISHED FLOOR TO CENTER OF OUTLET BOX UNLESS NOTED OTHERWISE ON PLANS. COORDINATE THE STANDARD MOUNTING HEIGHTS WITH MASONRY: A. SWITCHES +44" B. RECEPTACLES +20" C. VOICE/DATA +20" 5. WIRING SHALL INCLUDE FINAL CONNECTION TO ALL EQUIPMENT IN CONFORMANCE WITH EQUIPMENT SUPPLIER WIRING DIAGRAMS. 6. CONTRACTOR IS RESPONSIBLE FOR PROVIDING AN UPDATED AND COMPLETE TYPEWRITTEN CIRCUIT IDENTIFICATION SCHEDULE FOR EVERY PANELBOARD AFFECTED BY THIS PROJECT. 7. NEW OVERCURRENT PROTECTIVE DEVICES INSTALLED IN EXISTING PANELBOARDS OR DISTRIBUTION BOARDS SHALL MATCH THE TYPE AND AIC RATING OF EXISTING OVERCURRENT PROTECTIVE DEVICES. 8. BRANCH CIRCUIT CONDUCTORS SHALL BE MINIMUM #12 AWG UNLESS NOTED OTHERWISE IN SCHEDULES. WHERE 20A BRANCH CIRCUITS HAVE #8 AND LARGER WIRE SPECIFIED, #10 AWG WIRE SHALL BE USED FOR THE FINAL CONNECTION (15-FT MAXIMUM). 9. WHERE BRANCH CIRCUITS ARE GROUPED, SIZE CONDUIT AND DERATE CURRENT CARRYING CONDUCTORS PER NEC. 10. PROVIDE UL LISTED HANDLE TIES ON ALL MULTIWIRE BRANCH CIRCUITS PER NEC REQUIREMENTS. 11. SUPPORTS FROM STRUCTURE: NO ATTACHMENT OF ANY TYPE SHALL BE MADE TO BRIDGING OR JOIST WEB MEMBERS. UTILIZE ONLY THE TOP AND BOTTOM CHORDS FOR SUPPORTING THE ELECTRICAL SYSTEM INSTALLATIONS. 12. DEVICES SHOWN ON COOLER/FREEZER PANELS SHALL BE SURFACE MOUNTED UNLESS NOTED OTHERWISE. SEAL DEVICES TO COOLER/FREEZER PANELS WITH SILICONE SEALANT. 13. SURFACE MOUNTED CONDUIT ON COOLER/FREEZER PANELS OR IN FOOD PREP AREAS SHALL BE INSTALLED WITH GALVANIZED 1/2" STANDOFF CONDUIT HANGERS TO ALLOW FOR CLEANING. 14. ONLY FEEDER CIRCUITS NOTED ON THE ONE LINE DIAGRAM AND BRANCH CIRCUITS NOTED BY LEGEND SHALL BE INSTALLED UNDER SLAB. PROVIDE EXTERIOR COATED GRC BENDS ON ALL CONDUIT RUNS THAT HAVE 45 DEGREE BENDS OR GREATER. REFER TO SPECIFICATION SECTION 16.100 FOR UNDER SLAB. 15. SEISMIC ZONE REQUIREMENTS: PROVIDE EXPANSION COUPLINGS AND BRACING FOR ELECTRICAL EQUIPMENT AS REQUIRED BY LOCAL CODES. 16. EXISTING ELECTRICAL AND ALARM: A. WHERE DEMOLITION OR NEW CONSTRUCTION INTERRUPTS EXISTING ELECTRICAL CIRCUITS FEEDING EXISTING EQUIPMENT, DEVICES, OR LIGHTING TO REMAIN, BUT NOT SHOWN ON DRAWINGS, PROVIDE LABOR AND MATERIALS TO REWORK CIRCUITRY, AS REQUIRED, TO MAINTAIN EXISTING OPERATION. B. IF DEMOLITION OR NEW CONSTRUCTION WILL DISRUPT EXISTING UNDERGROUND SERVICES (ELECTRICAL, TELEPHONE, PARKING LOTLIGHTING CIRCUITRY, ETC.) PROVIDE ALL MATERIALS AND LABOR AS REQUIRED TO REROUTE, SLEEVE, OR OTHERWISE REWORK THESE SERVICES TO MAINTAIN THEIR EXISTING OPERATION. C. EXERCISE CAUTION AROUND ALARM AND SECURITY CABLES DURING DEMOLITION AND CONSTRUCTION. PROTECT ALARM AND SECURITY CABLES FROM ACCIDENTAL DAMAGE SO THAT SYSTEMS REMAIN OPERATIONAL AT ALL TIMES. D. DISPOSE OF ALL REMOVED MATERIALS, UNLESS OTHERWISE NOTED. 17. EXISTING ELECTRICAL DEMOLITION: A. GENERAL: REMOVE OR RELOCATE EXISTING ELECTRICAL EQUIPMENT, CONDUIT AND CONDUCTORS AS INDICATED ON THE DRAWINGS, OR ONLY AS REQUIRED BY DEMOLITION. REMOVE ALL PANELBOARDS, DISCONNECT SWITCHES, BOXES, RELAYS, TIME SWITCHES, LIGHTS, DEVICES, ETC., WHICH WILL NOT BE REUSED. B. SALES FLOOR: REMOVE UNUSED POWER DROP CONDUIT, CONDUCTORS AND RELATED DEVICES SERVING SALES AREA GONDOLAS BEING RELOCATED OR REMOVED. EXISTING CONDUIT AND CONDUCTORS MAY BE REUSED FOR NEW POWER DROPS WHERE SIZE, RATING, AND CONDITION MEET REQUIREMENTS INDICATED ON PLANS AND ALL U.L. RATINGS. REMOVE ALL UNUSED CONDUIT AND CONDUCTORS BACK TO POINT OF ORIGIN WHENEVER FEASIBLE. IF CIRCUIT IS NOT REUSED, REMOVE CIRCUIT BREAKER AND REPLACE WITH FILLER PLATE. EXCEPTION: DISTRIBUTION AND POWER SWITCH BREAKERS SHALL BE ETR AS "SPARE". PROVIDE HANDLE LOCK OFF DEVICE TO LOCK "SPARE" CIRCUIT BREAKER IN THE "OFF" POSITION. UPDATE TYPEWRITTEN CIRCUIT IDENTIFICATION SCHEDULE AS "SPACE" OR "SPARE". C. CONDUIT AND WIRING TO BE ABANDONED IN CEILING SPACES AND OTHER NON-PUBLIC AREAS (I.E., THROUGH STOCKROOM AREA): CUT WIRING LOOSE AND REMOVE FROM RACEWAY(S), LEAVING RACEWAY(S) IN PLACE. CONDUIT TO BE ABANDONED IN WALLS OR FLOORS SHALL BE REMOVED BACK TO FINISHED SURFACE AND CAPPED INSIDE. REPAIR SURFACE(S) TO MATCH ADJACENT. D. ALL CIRCUIT BREAKERS SERVING BRANCH CIRCUITS TO BE REMOVED SHALL ALSO BE REMOVED. REMOVE CIRCUIT BREAKER AND REPLACE WITH FILLER PLATE. EXCEPTION: DISTRIBUTION AND POWER SWITCH BREAKERS SHALL BE ETR AS "SPARE". PROVIDE HANDLE LOCK OFF DEVICE TO LOCK "SPARE" CIRCUIT BREAKER IN THE "OFF" POSITION. UPDATE TYPEWRITTEN CIRCUIT IDENTIFICATION SCHEDULE AS "SPACE" OR "SPARE". E. DEMOLISHED FLUORESCENT LIGHT FIXTURES: REFER TO SELECTIVE SITE DEMOLITION SPECIFICATION FOR DISPOSAL OF LIGHT FIXTURE. F. BUILDING COMPONENTS ABANDONED BY THE SCOPE OF WORK SHALL BE SECURED TO PREVENT FALLING, LOOSENING, OR CREATING DAMAGE OF ANY KIND IN THE FUTURE. 18. DATA AND PHONE CONDUIT INSTALLATION MILESTONE DATE: ALL RACEWAY AND CONDUIT SLEEVES FOR DATA AND PHONE CABLING TO BE INSTALLED 3 WEEKS PRIOR TO CONTRACT SUBSTANTIAL COMPLETION DATE. 19. ETHERNET CABLE: A. FURNISH AND INSTALL JUNCTION BOXES AS SHOWN ON PLANS. PROVIDE CONDUIT AS REQUIRED BY LOCAL CODES AND/OR ORDINANCES. B. ETHERNET CABLE IS FURNISHED BY OTHERS. C. ELECTRICAL CONTRACTOR SHALL INSTALL CABLE IN POW ER POLES. D. ELECTRICAL CONTRACTOR SHALL INSTALL OTHER CABLE AS DIRECTED BY WALMART CONSTRUCTION MANAGER. GENERAL NOTES 08.28.20 1. EXIT SIGN MOUNTING A. WALL FIXTURE: CENTER 12" ABOVE DOOR OPENING. B. CEILING FIXTURE: ON CEILING OR AT HEIGHT SPECIFIED ON DRAWINGS. C. PENDANT FIXTURE: MATCH HEIGHT OF EXISTING PENDANT MOUNTED EXIT SIGNS. IF STORE DOES NOT HAVE PENDANT MOUNTED EXIT SIGNS, THEN PENDANT MOUNT SIGN 24" BELOW BOTTOM OF BAR JOIST. D. VERIFY MOUNTING HEIGHT WITH AHJ. E. COORDINATE LOCATIONS OF EXIT SIGNS TO ENSURE STORE SIGNAGE DOES NOT OBSTRUCT THEIR VIEW. F. THE USE OF TRITIUM BASED RADIOACTIVE EXIT SIGNAGE IS PROHIBITED. 2. EMERGENCY LIGHT FIXTURE INSTALLATION A. WALL FIXTURE: 12" BELOW FINISHED CEILING OR +10'-0" IN AREAS OF EXPOSED STRUCTURE, UNLESS NOTED OTHERWISE. B. PENDANT FIXTURE: BOTTOM CHORD OF BAR JOIST OR AT HEIGHT SPECIFIED ON DRAWINGS. C. REMOTE HEAD FIXTURE: HEADS CENTERED ABOVE DOOR OPENING +9'-0", UNLESS NOTED OTHERWISE AND BATTERY PACK MOUNTED ON INTERIOR SIDE OF WALL 12" BELOW FINISHED CEILING OR AT BAR JOIST IN AREAS OF EXPOSED STRUCTURE. D. REFER TO MANUFACTURER'S WRITTEN INSTRUCTIONS. ALLOW BATTERY TO CHARGE CONTINUOUSLY FOR A MINIMUM OF 24 HOURS BEFORE INITIAL TESTING. E. AFTER EMERGENCY LIGHT HAS BEEN POWERED DO NOT TURN OFF FOR EXTENDED PERIODS OF TIME. 3. EXIT SIGNS, EMERGENCY LIGHTS AND NIGHT LIGHTS SHALL NOT BE SWITCHED. 4. IN AREAS OF OPEN STRUCTURE, MOUNT STRIP FIXTURE TO BOTTOM CHORD OF BAR JOIST, UNLESS NOTED OTHERWISE. 5. PROVIDE SEPARATE BOXES FOR GANGED SWITCHES ON SEPARATE BRANCH CIRCUITS. 6. FIXTURES DENOTED WITH "ABJ" ARE TO BE FASTENED ON UNISTRUT CHANNELS MOUNTED TO THE BOTTOM SIDE OF THE TOP CHORD OF BAR JOISTS. LOCATE THE FIXTURES RUNNING PERPENDICULAR TO BAR JOISTS WITHIN BAR JOISTS WEBBING SPACES. DO NOT FASTEN FIXTURE OR UNISTRUT CHANNELS TO ROOF DECK. GENERAL LIGHTING NOTES 01.31.20 1. OCCUPANCY SENSORS IN RESTROOMS SHALL BE PROGRAMMED FOR AUTOMATIC ON AND MAXIMUM AVAILABLE TIME DELAY SETTINGS. 2. OCCUPANCY SENSORS IN DELI, PRODUCE, AND BAKERY PREP AREAS SHALL BE PROGRAMMED WITH MAXIMUM AVAILABLE TIME DELAY SETTINGS. 3. OCCUPANCY SENSORS IN WALK-IN COOLERS/FREEZERS SHALL BE LOW TEMPERATURE RATED, WALL MOUNTED 6" ABOVE DOOR. ADJUST AIMING FOR MAXIMUM COVERAGE, 10 MINUTE TIME DELAY. 4. ALL OTHER OCCUPANCY SENSORS SHALL BE PROGRAMMED WITH THE MINIMUM AVAILABLE TIME DELAY SETTING UNLESS NOTED OTHERWISE. 5. ALL SINGLE-POLE OCCUPANCY SENSORS SHALL BE PROGRAMMED FOR MANUAL ON LIGHTING CONTROL UNLESS NOTED OTHERWISE. 6. ALL BI-LEVEL OCCUPANCY SENSORS SHALL BE PROGRAMMED FOR AUTOMATIC ON LIGHTING CONTROL FOR 50% OF FIXTURES AND WITH MANUAL ON MODE FOR REMAINING FIXTURES. 7. WHERE TWO OCCUPANCY SENSORS ARE SHOWN IN THE SAME LOCATION WIRE FOR PARALLEL OPERATION. OCCUPANCY SENSOR NOTES 01.31.20 A R S OS B DH J SS OS2S OSS 3S 4S DS MS VSS KS S SINGLE POLE SWITCH CIRCUIT, CONCEALED IN WALLS OR CEILING, E INDICATES EXISTING WIRING SMOKE DETECTOR SAIL SWITCH JUNCTION BOX HORN / STROBE ABBREVIATIONS BUZZER CIRCUIT, CONCEALED IN SLAB FLOOR, E INDICATES EXISTING WIRING CONDUIT SLEEVE SURFACE MOUNTED PANELBOARD FLUSH MOUNTED PANELBOARD CIRCUIT, EXPOSED, E INDICATES EXISTING WIRING LOW VOLTAGE WIRING TELEPOWER POLE TELEPHONE / DATA BOX FOR ISD TELEPHONE, FLUSH FLOOR PUSH BUTTON MOTOR ALARM JUNCTION BOX, FOR REMOTE TEST/RESET (WALL MOUNTED/CEILING MOUNTED) EQUIPMENT CONNECTION POINT (PROVIDED WITH EQUIPMENT) NON-FUSED DISCONNECT RECEPTACLE, PLUG-MOLD RECEPTACLE, SIMPLEX RECEPTACLE, SPECIAL JUNCTION BOX (WALL MOUNTED/CEILING MOUNTED) ALARM JUNCTION BOX, (WALL MOUNTED/CEILING MOUNTED) RECEPTACLE, DOUBLE DUPLEX, ISOLATED GROUND FUSED DISCONNECT 4-WAY SWITCH RECEPTACLE, DUPLEX ISOLATED GROUND FLUSH FLOOR RECEPTACLE, DOUBLE DUPLEX RECEPTACLE, DUPLEX FLUSH FLOOR VARIABLE SPEED SWITCH KEYED SWITCH DIMMER SWITCH RECEPTACLE, DUPLEX, MOUNTED HORIZONTALLY RECEPTACLE, DUPLEX MANUAL MOTOR SWITCH 3-WAY SWITCH RECEPTACLE, DUPLEX ISOLATED GROUND LIGHT FIXTURE, NIGHT LIGHT VOLUMETRIC LIGHT FIXTURE LIGHT FIXTURE (WALL MOUNTED/CEILING MOUNTED) LIGHT FIXTURE (SYMBOLS APPLY ONLY WHEN USED ON DRAWINGS) SYMBOL DESCRIPTION RECEPTACLE, DUPLEX TWIST LOCK, ISOLATED GROUND, L5-15R, UNO SINGLE POLE OCCUPANCY SENSOR SWITCH LOW VOLTAGE CABLE BOX FOR OTHER DOOR HOLD OPEN RECEPTACLE, DUPLEX TWIST LOCK, L5-15R, UNO RECEPTACLE, SIMPLEX TWIST LOCK, ISOLATED GROUND, L5-15R, UNO RECEPTACLE, SIMPLEX TWIST LOCK, L5-15R, UNO WALL MOUNTED OCCUPANCY SENSOR SWITCH, ONE-DIRECTION SENSING RECEPTACLE, GFI DOUBLE POLE OCCUPANCY SENSOR SWITCH T THERMOSTAT (WALL MOUNTED/CEILING MOUNTED) EXIT FIXTURE (WALL MOUNTED/CEILING MOUNTED) EMERGENCY LIGHT (WALL MOUNTED/CEILING MOUNTED) EMERGENCY LIGHT REMOTE HEADS (WALL MOUNTED/CEILING MOUNTED) a, b, c LOWER CASE LETTERS INDICATE SWITCHING CONFIGURATION AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE C CONDUIT CCT CIRCUIT CF CEILING FAN CW CASH WRAP EC ELECTRICAL CONTRACTOR EF EXHAUST FAN ETR EXISTING TO REMAIN EWC ELECTRIC WATER COOLER G GROUND GC GENERAL CONTRACTOR GFEP GROUND FAULT EQUIPMENT PROTECTION GFI GROUND FAULT CIRCUIT INTERRUPTER HD HAND DRYER IG ISOLATED GROUND LCU LIGHTING CONTROL UNIT NL NIGHT LIGHT NTS NOT TO SCALE REC REFRIGERATION ELECTRICAL CONTRACTOR RC REFRIGERATION CONTRACTOR RH RADIANT HEATER SC SECURITY CAMERA TR TAMPER RESISTANT TYP TYPICAL UH UNIT HEATER UNO UNLESS NOTED OTHERWISE WH WATER HEATER WP WEATHER PROOF WR WEATHER RESISTANT ELECTRICAL SYMBOLS LEGEND TIME CLOCKTC TRACK LIGHTING 04.24.20 OS CEILING MOUNTED OCCUPANCY SENSOR SWITCH, FOUR-DIRECTION SENSING 1/4" = 1'-0" 1 FRONT RESTROOM POWER PLAN 1/4" = 1'-0" 2 REAR RESTROOM POWER PLAN KEYNOTES 16.131 CONNECT TO EXISTING CIRCUIT. 16.145 CONNECT CIRCUIT(S) TO EXISTING BRANCH CIRCUITRY. MINIMUM WIRE SIZE AND PANELBOARD CIRCUIT ARE NOTED. VERIFY SIZE, RATING AND CONDITION OF EXISTING BRANCH CIRCUIT CONDUIT AND WIRE PRIOR TO USE TO ENSURE THAT THEY MEET REQUIRED SIZE, AND ALL U.L. RATINGS AND REPLACE AS REQUIRED. 16.400 SCENT SYSTEM: ONCE INSTALLATION OF ALL SCENT SYSTEM RECEPTACLES HAS BEEN FINALIZED, CONTACT OWNERS SCENT SYSTEM VENDOR FOR INSTALLATION OF SCENT SYSTEMS PER SPEC SECTION APPENDIX A. 16.400A SCENT SYSTEM RECEPTACLES: MOUNT AT 13" BELOW CEILING AND ENSURE NO OBSTRUCTIONS WITHIN 4" LEFT AND RIGHT OF RECEPTACLE. 16.408 NEW HAND DRYER: REFER TO ARCHITECTURAL DETAILS AND MANUFACTURER'S INSTRUCTIONS FOR ROUGH-IN AND MOUNTING REQUIREMENTS. 16.409 HAND DRYER TO BE REPLACED: REFER TO ARCHITECTURAL DETAILS AND MANUFACTURER'S INSTRUCTIONS FOR ROUGH-IN AND MOUNTING REQUIREMENTS. 16.462 EXISTING OFFICE AREAS AND/OR RESTROOMS, WILL BE REFURBISHED BY OTHERS. REMOVE ALL ELECTRICAL ITEMS FROM WALLS AND CEILING, INCLUDING HAND DRYERS, RECEPTACLES, SWITCHES, AND LIGHTING FIXTURES AS REQUIRED. INSTALL AND RECONNECT AFTER NEW FINISHES ARE IN PLACE. COORDINATE EXTENT OF WORK WITH GENERAL CONTRACTOR AND WAL-MART CONSTRUCTION MANAGER. 16.477 FURNISH AND INSTALL NEW CIRCUIT BREAKER (##A-#P) IN EXISTING PANELBOARD INDICATED. PROVIDE CIRCUIT BREAKER LOCKING DEVICE (LOCK-OFF FOR MAINTENANCE). E.C. SHALL MATCH MANUFACTURER, TYPE AND AIC RATINGS OF EXISTING CIRCUIT BREAKERS. 1/8" = 1'-0" 4 EDC #2 POWER PLAN "OW" FIXTURES AND LAMPS ARE FURNISHED BY THE OWNER FOR INSTALLATION BY THE CONTRACTOR. "GC" FIXTURES AND LAMPS ARE FURNISHED AND INSTALLED BY THE CONTRACTOR. LIGHT FIXTURE SCHEDULE TYPE SUPPLIED BY DESCRIPTION VENDOR/MFR MODEL VOLTAGE INPUT VA COLOR TEMP LIGHT SOURCE LAMP QTY MOUNTING COUNT 68R OW CIRCULAR RECESSED DOWNLIGHT ACUITY BRANDS LIGHTING INC LBR6 07LM 40K AR LSS MWD MVOLT UGZ 120/277 8 VA 4000K INTEGRAL LED - RECESSED 55 ISSUE BLOCK