Loading...
2021.0028 MU Civil Plans (Approved) 10.19.2021T TAHOMA BOULEVARD SE BERRY VALLEY RD SE ROAD ATHE EAST HALF OF THE NORTHWEST QUARTER OF THE NORTHWEST QUARTER OF THE SOUTHEAST QUARTER OF SECTION 24, TOWNSHIP 17 NORTH, RANGE 1 EAST, W.M. EXCEPT COUNTY ROADS; EXCEPT PORTION TAKEN FOR BERRY VALLEY ROAD PER AUDITOR'S FILE NO. 3980984. SITUATE IN THURSTON COUNTY, STATE OF WASHINGTON. NAVD 1988 VERTICAL DATUM ON ORTHOMETRICALLY CORRECTED GPS OBSERVATIONS USING WSRN AND GEOID 2012A. NAD 1983/11 WASHINGTON STATE PLANE SOUTH PROJECTION, BASED ON GPS OBSERVATIONS USING WSRN AND GEOID 2012A. UNITS OF MEASUREMENT ARE US SURVEY FEET. T FOUND MONUMENT AS NOTED SET NAIL AND WASHER SET REBAR AND CAP FOUND PROPERTY CORNER SIGN AS NOTED TEST PIT CLEANOUT SANITARY SEWER MANHOLE STORM CATCH BASIN STORM MANHOLE GAS VALVE GUY ANCHOR UTILITY POWER POLE JUNCTION BOX LUMINAIRE COMMUNICATIONS MANHOLE TELEPHONE VAULT BLOW OFF VALVE FIRE HYDRANT IRRIGATION CONTROL VALVE WATER METER WATER VALVE CONIFEROUS TREE AS NOTED DECIDUOUS TREE AS NOTED LEFT TURN ARROW STRAIGHT ARROW STORM LINE SEWER LINE WATER LINE GAS LINE ELECTRICAL LINE COMMUNICATION LINE OVERHEAD UTILITIES FENCE UNKNOWN VAULT ASPHALT CONCRETE 1 2 3 4 TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 253.383.2572 FAX 28 SKML/EAML/EA 10/18/2021 CIVIL PERMIT SET 2210016.10 PO BOX 597 PUYALLUP, WA 98371 JERRY SCHUUR SCHUUR BROTHERS CONSTRUCTION TAHOMA BOULEVARD APARTMENTS A PORTION OF THE NW 1/4 OF THE SE 1/4 OF SEC. 24, TWN. 17 N., RGE. 01 E. W.M. CITY OF YELM, THURSTON COUNTY, WASHINGTON. TAHOMA BOULEVARD APARTMENTS LEGAL DESCRIPTION LEGEND VERTICAL DATUM BASIS OF BEARING N GRAPHIC SCALE 0 50 100 1" = 50 FEET 25 DATE: October 5, 2021 FILENAME: Q:\2021\2210016\10_CIV\CAD\_Site Development\2210016-SH-COVR.dwg C0.1 1 COVER SHEET AHBL ENGINEERS, PLANNERS, & SURVEYORS 2215 NORTH 30TH STREET, SUITE 300 TACOMA, WA 98403 PH. (253) 383-2422 FAX (253) 383-2572 CONTACT: MATT WEBER, P.E. SCHUUR BROTHERS CONSTRUCTION 9709 124TH ST E PUYALLUP, WA 98371 PH: (253) 841-8888 CONTACT: MR. JERRY SCHUUR OWNER/DEVELOPER CIVIL ENGINEER SURVEYOR AHBL ENGINEERS, PLANNERS, & SURVEYORS 2215 NORTH 30TH STREET, SUITE 300 TACOMA, WA 98403 PH. (253) 383-2422 FAX (253) 383-2572 CONTACT: DAVE FOLLANSBEE, PLS EARTHWORK QUANTITIES ADDRESS:15035 BERRY VALLEY RD SE YELM, WA TPN:21724420200 SITE AREA:4.99 AC IMPERVIOUS: 2.94 AC (59%) PERVIOUS:2.05 AC (41%) SITE DATA 1ST S T S VICINITY MAP SCALE: 1" = 1/4 MILE (1,320') SITE TAHOMA BLVD SE BERRY VALLEY RD SE E Y E L M A V E C O A T E S A V E NW LONGMIRE ST SECULLENS RD SE93RD AVE SE CRYSTAL SPRINGS ST NWTORNADO ALLEY BLDG 1 BLDG 2 BLDG 3 BLDG 4 NATURE BY DESIGN 1320 ALAMEDA AVENUE, SUITE B FIRCREST, WA 98466 PH. (253) 460-6067 CONTACT: KATHY OWENS SOUND SOUTH GEOTECHNICAL CONSULTING P.O.BOX 39500 LAKEWOOD, WA 98496 PH: (253) 973-0515 CONTACT: C PEDERSEN GEOTECH LANDSCAPE ARCHITECT MDP CONSULTING P.O.BOX 1303 SUMNER, WA 98390 PH: (253) 286-7973 CONTACT: IF WORKERS ENTER ANY TRENCH OR OTHER EXCAVATION FOUR OR MORE FEET IN DEPTH THAT DOES NOT MEET THE OPEN PIT REQUIREMENTS OF WSDOT STANDARD SPECIFICATIONS SECTION 2-09.3(3)B, IT SHALL BE SHORED AND CRIBBED. THE CONTRACTOR ALONE SHALL BE RESPONSIBLE FOR WORKER SAFETY AND AHBL ASSUMES NO RESPONSIBILITY. ALL TRENCH SAFETY SYSTEMS SHALL MEET THE REQUIREMENTS OF THE WASHINGTON INDUSTRIAL SAFETY AND HEALTH ACT, CHAPTER 49.17 RCW. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE APPROXIMATE ONLY AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR ITS REPRESENTATIVE. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK AND AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES THAT HAPPEN DUE TO THE CONTRACTOR'S FAILURE TO LOCATE EXACTLY AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES. AHBL ASSUMES NO LIABILITY FOR THE LOCATION OF UNDERGROUND UTILITIES. THE EXISTING CULTURAL AND TOPOGRAPHIC DATA SHOWN ON THESE DRAWINGS HAS BEEN PREPARED, IN PART, BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, AHBL CANNOT ENSURE ACCURACY AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THAT INFORMATION OR FOR ANY ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THESE DRAWINGS AS A RESULT. AN AUTOCAD FILE IS AVAILABLE TO ASSIST THE CONTRACTOR WITH SITE LAYOUT. TRENCH NOTE UTILITY NOTE FILL SPECIFICATION FILL MATERIAL SHALL NOT CONTAIN PETROLEUM PRODUCTS, OR SUBSTANCES WHICH ARE HAZARDOUS, DANGEROUS, TOXIC, OR WHICH OTHERWISE VIOLATE ANY STATE, FEDERAL, OR LOCAL LAW, ORDINANCE, CODE, REGULATION, RULE, ORDER, OR STANDARD. TOPOGRAPHIC NOTE AUTOCAD NOTE EXISTING PROPOSED FORCE MAIN SEWER STEP TANK SHEET INDEX Sheet Number Sheet Title C0.1 COVER SHEET C0.2 EXISTING CONDITIONS C1.0 TESC AND DEMOLITION PLAN C1.1 TESC NOTES AND DETAILS C1.2 TESC NOTES AND DETAILS C2.0 HORIZONTAL CONTROL AND SURFACING PLAN C2.1 SURFACING NOTES AND DETAILS C2.2 SURFACING NOTES AND DETAILS C3.0 GRADING AND DRAINAGE PLAN C3.1 STORM TABLES C3.2 SITE SECTIONS C3.3 STORM PROFILES C3.4 GRADING AND DRAINAGE NOTES AND DETAILS C3.5 GRADING AND DRAINAGE NOTES AND DETAILS C4.0 OVERALL SEWER AND WATER PLAN C4.1 WATER PLAN AND PROFILE C4.2 WATER PLAN AND PROFILE C4.3 WATER PLAN AND PROFILE C4.4 SEWER NOTES AND DETAILS C4.5 SEWER NOTES AND DETAILS C4.6 SEWER NOTES AND DETAILS C4.7 WATER NOTES AND DETAILS C4.8 WATER NOTES AND DETAILS C4.9 WATER NOTES AND DETAILS L1 LANDSCAPE PLAN L2 SOUTH LANDSCAPE PLAN L3 NORTH LANDSCAPE PLAN L4 DETAIL SHEET CUT = 3,070 CUBIC YARDS FILL = 2,860 CUBIC YARDS NET = 210 CUBIC YARDS (EXPORT) NOTES: THE ABOVE QUANTITIES ARE ESTIMATES ONLY INTENDED FOR THE PERMITTING PROCESS. DO NOT USE FOR BID PURPOSES. THE QUANTITIES DO NOT HAVE STRIPPING, COMPACTION, OR CUT AND FILL ADJUSTMENT FACTORS APPLIED TO THEM, NOR DO THEY ACCOUNT FOR PAVEMENT, SIDEWALK OR BUILDING SECTIONS. TEMPORARY ACCESS TO BERRY VALLEY RD SE. ACCESS SHALL BE REMOVED ONCE ACCESS TO ROAD A IS AVAILABLE 10/19/2021 WELL HOUSE APPROXIMATE LOCATION OF EXISTING SEPTIC DRAIN FIELD 1 2 3 4 TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 253.383.2572 FAX 28 SKML/EAML/EA 10/18/2021 CIVIL PERMIT SET 2210016.10 PO BOX 597 PUYALLUP, WA 98371 JERRY SCHUUR SCHUUR BROTHERS CONSTRUCTION TAHOMA BOULEVARD APARTMENTS A PORTION OF THE NW 1/4 OF THE SE 1/4 OF SEC. 24, TWN. 17 N., RGE. 01 E. W.M. CITY OF YELM, THURSTON COUNTY, WASHINGTON. TAHOMA BOULEVARD APARTMENTS DATE: September 9, 2021 FILENAME: Q:\2021\2210016\10_CIV\CAD\_Site Development\2210016-SH-EX-COND.dwg C0.2 2 EXISTING CONDITIONS N GRAPHIC SCALE 0 40 80 1" = 40 FEET 20 THE EAST HALF OF THE NORTHWEST QUARTER OF THE NORTHWEST QUARTER OF THE SOUTHEAST QUARTER OF SECTION 24, TOWNSHIP 17 NORTH, RANGE 1 EAST, W.M. EXCEPT COUNTY ROADS; EXCEPT PORTION TAKEN FOR BERRY VALLEY ROAD PER AUDITOR'S FILE NO. 3980984. SITUATE IN THURSTON COUNTY, STATE OF WASHINGTON. LEGAL DESCRIPTION TAHO M A B L V D ROAD ANAVD 1988 VERTICAL DATUM ON ORTHOMETRICALLY CORRECTED GPS OBSERVATIONS USING WSRN AND GEOID 2012A. NAD 1983/11 WASHINGTON STATE PLANE SOUTH PROJECTION, BASED ON GPS OBSERVATIONS USING WSRN AND GEOID 2012A. UNITS OF MEASUREMENT ARE US SURVEY FEET. VERTICAL DATUM BASIS OF BEARING 10/19/2021 IP CD ID TYP. TYP. INTERCEPTOR DITCH 0.30% MINIMUM INTERCEPTOR DITCH 0.30% MINIMUM INTERCEPTOR DITCH 0.30% MINIMUM 47.00'127.00'25' TYP. FL: 344.44 FL: 346.02 FL: 346.94 FL: 347.18 CE FL:345.29 FL: 344.84 FL: 344.56 FL:345.79 INTERCEPTOR DITCH 0.30% MINIMUM FL: 345.04 FL: 347.62 342344346346346 3 4 8 346 346 346346346348350352 20' 1 2 3 4 TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 253.383.2572 FAX 28 SKML/EAML/EA 10/18/2021 CIVIL PERMIT SET 2210016.10 PO BOX 597 PUYALLUP, WA 98371 JERRY SCHUUR SCHUUR BROTHERS CONSTRUCTION TAHOMA BOULEVARD APARTMENTS A PORTION OF THE NW 1/4 OF THE SE 1/4 OF SEC. 24, TWN. 17 N., RGE. 01 E. W.M. CITY OF YELM, THURSTON COUNTY, WASHINGTON. TAHOMA BOULEVARD APARTMENTS DATE: September 9, 2021 FILENAME: Q:\2021\2210016\10_CIV\CAD\_Site Development\2210016-SH-TESC.dwg C1.0 3 TESC AND DEMOLITION PLANNGRAPHIC SCALE 0 30 60 1" = 30 FEET 15 TAHOMA BLVD SEROAD 'A' (BY OTHERS) BLDG 1 BLDG 2 BLDG 3 BLDG 4 FF: 347.75 FF: 347.38 FF: 346.78 FF: 346.43 BERRY VALLEY RDTESC AND DEMO LEGEND INLET PROTECTION CLEARING LIMITS SILT FENCE INTERCEPTOR DITCH RIP-RAP PROTECTION 4"x6" SPALLS DEMO EXISTING UTILITY CONSTRUCTION ENTRANCE REMOVE EXISTING ASPHALT REMOVE EXISTING FENCE EXISTING GRADE CONTOUR ROCK CHECK DAM EMERGENCY OVERFLOW SPILLWAY EXISTING TREE TO BE REMOVED SF CL IP CE ELEV CONSTRUCTION SEQUENCE 1.ARRANGE AND ATTEND PRE-CONSTRUCTION CONFERENCE WITH THE CITY OF YELM AND CONFIRM REQUIRED INSPECTIONS. 2.STAKE CLEARING AND GRUBBING LIMITS. 3.INSTALL PERIMETER CONTROLS INCLUDING FILTER FABRIC FENCE, OFFSITE INLET PROTECTION, AND CONSTRUCTION ENTRANCE. 4.FLAG INFILTRATION AREA TO LIMIT COMPACTION AND SEDIMENT LADEN RUNOFF FROM THIS AREA. 5.INSTALL/IMPLEMENT EROSION CONTROL BMPS. 6.CONSTRUCT TEMPORARY SEDIMENT CONTROL POND PER PLAN. 7.PROVIDE SITE DEMOLITION AND ABANDON/DECOMISSION WELL AND SEPTIC TANK PER HEALTH DEPARTMENT STANDARDS. 8.CLEAR AND GRUB SITE AS NECESSARY TO INSTALL SITE IMPROVEMENTS. DURING WET SEASON, DO NOT CLEAR ANY MORE AREA THAN CAN BE STABILIZED, PER THE GRADING AND EROSION CONTROL PLAN, IN A GIVEN WORKDAY. DO NOT COMPACT INFILTRATION AREAS. 9.GRADE SITE PER GRADING PLAN. 10.INSTALL STORM SYSTEM PER PLANS. INSTALL INLET PROTECTION FOR NEW CATCH BASINS. 11.INSTALL FORCE MAIN AND STEP SYSTEM TANKS. 12.INSTALL WATER MAIN AND FIRE SUPPRESSION LINES. 13.CONSTRUCT DRIVE AREAS. 14.INSTALL INFILTRATION TRENCH & PERKFILTER VAULT. DO NOT PLACE INFILTRATION TRENCH ON LINE UNTIL THE SITE IS FULLY STABILIZED. 15.STABILIZE UNPAVED AREAS OF THE SITE BY HYDRO-SEEDING OR OTHER APPROPRIATE METHODS PER THE EROSION CONTROL NOTES. 16.ONCE THE SITE HAS BEEN FULLY STABILIZED PLACE INFILTRATION FACILITIES ONLINE. 17.PAVE ONSITE DRIVE AREAS. 18.REMOVE ALL TEMPORARY EROSION CONTROL FACILITIES AFTER SITE HAS BEEN PERMANENTLY STABILIZED AND APPROVED BY THE CITY. 19.CLEAN STORM DRAINAGE SYSTEM PIPING AND CATCH BASINS. 20.CALL FOR FINAL INSPECTION(S). CONTRACTOR TO STABILIZE ALL DISTURBED PORTIONS OF THE SITE USING SEED, MULCH, OR OTHER ENGINEER APPROVED BMP IN ACCORDANCE WITH SWMM. SF CL PROPOSED TEMPORARY INFILTRATION POND BOTTOM INFILTRATION ELEV: 341.50 BOTTOM AREA: 1,998± SF SILT FENCE 1 C1.1 3 C1.1 3 C1.1 1 C1.2 5 C1.1 4 C1.1 51 LF 12" CPEP TO LEVEL SPREADER, MAINTAIN 1% MIN. SLOPE EMERGENCY OVERFLOW SPILLWAY, SEE DETAIL 4 C1.1 SEDIMENT POND RISER 6 C1.1 CD ID KEY IN 6-FOOT BERM PER DETAIL 5 C1.1 PROTECT EXISTING ASPHALT PROTECT EXISTING UTILITY PROTECT EXISTING UTILITY PROTECT EXISTING UTILITY DEMOLISH EXISTING BUILDING DEMOLISH EXISTING BUILDING REMOVE EXISTING GRAVEL AS NECESSARY DEMOLISH EXISTING BUILDING PROTECT FUTURE INFILTRATION AREA SUBGRADE 1 C1.2 REMOVE EXISTING CONCRETE DRIVEWAY TO NEXT NEAREST JOINT AFTER CONTRUCTION IS COMPLETE. REFER TO SHEET x FO CURB, GUTTER & SIDEWALK REPLACEMENT USE EXISTING PAVED DRIVEWAY FOR STABILIZED CONSTRUCTION ENTRANCE ACCESS THE EXISTING WELL SHALL BE DECOMMISSIONED ACCORDING TO DEPARTMENT OF ECOLOGY STANDARDS AND WATER RIGHTS, IF ANY, SHALL BE DEDICATED TO THE CITY. EXISTING SEPTIC SYSTEM SHALL BE DECOMMISSIONED ACCORDINGLY TO THURSTON CO. HEALTH DEPARTMENTS STANDARDS. 10/19/2021 1 2 3 4 TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 253.383.2572 FAX 28 SKML/EAML/EA 10/18/2021 CIVIL PERMIT SET 2210016.10 PO BOX 597 PUYALLUP, WA 98371 JERRY SCHUUR SCHUUR BROTHERS CONSTRUCTION TAHOMA BOULEVARD APARTMENTS A PORTION OF THE NW 1/4 OF THE SE 1/4 OF SEC. 24, TWN. 17 N., RGE. 01 E. W.M. CITY OF YELM, THURSTON COUNTY, WASHINGTON. TAHOMA BOULEVARD APARTMENTS DATE: September 9, 2021 FILENAME: Q:\2021\2210016\10_CIV\CAD\_Site Development\2210016-SH-TESC.dwg C1.1 4 TESC NOTES AND DETAILS OVERFLOW SPILLWAY 8.1' MINIMUM WIDTH 0.8' 0.5' OF 3 4" -3" WASHED ROCK 0.5' OF QUARRY SPALLS 3 1 SPILLWAY ELEVATION POND 1 = 345.2 12" CPEP BERM ELEVATION: POND 1 = 346.0 6' MIN. MAX WATER SURFACE ELEV. POND 1 = 345.0 OUTLET ELEV. POND 1 = 342.0 BOTTOM ELEVATION POND 1 = 341.5 2:1 MAX .3H:1V MAX.3H:1V MAX . MIN 3' SETTLING DEPTH NOTES: 1. A STAFF GAUGE SHALL BE PLACE IN THE POND WITH 1 FOOT MEASUREMENTS SHOWN TO A HEIGHT OF 5 FEET ABOVE POND BOTTOM TO MONITOR SEDIMENT LEVELS. PRIMARY OVERFLOW, PROVIDE TRASH RACK SEDIMENT POND RISER SEDIMENT STORAGE 0.5' MIN. 2.6-2.7' DISCHARGE PER PLANS EMBANKMENT COMPACTED TO 95%, PERVIOUS MATERIAL SUCH AS GRAVEL OR CLEAN SAND SHALL NOT BE USED PER PLANS EMERGENCY SPILLWAY SPILLWAY ELEVATION: POND 1 = 345.2 POND 1 = 1.0' 0.8' SPILLWAY (0.5' FREEBOARD + 0.3' PONDING) CONCRETE BASE 1 3' MIN. 18" MIN. 6" MIN. 2.0' MIN. PROVIDE ADEQUATE STRAPPING 48" CORRUGATED METAL RISER PROMINENT FOOT MARKINGS ON RISER SHOWING HEIGHT ABOVE POND BOTTOM DEWATERING ORIFICE, SCHEDULE 40 STEEL STUB POND 1= 2.6" TACK WELD WATERTIGHT COUPLING DISCHARGE PER PLAN SEE SEDIMENT POND SECTION FOR OUTLET ELEVATION ALTERNATE: METAL STAKES AND WIRE MAY BE USED TO PREVENT FLOTATION 8" PERFORATED POLYETHYLENE DRAINAGE TUBING, TUBING SHALL COMPLY WITH ASTM F667 AND AASHTO M294 POLYETHYLENE CAP SHUT-OFF VALVE, EXTEND OPERATING HANDLE TO TOP OF RISER CHECK DAM 20 5 10 10 6 15 5 20 4 25 2 50 100 % 1 SPACING (FT.) DITCH SLOPE CHECK DAM SPACING A AND B ARE OF EQUAL ELEVATION L = THE DISTANCE SUCH THAT POINTS 2:1 SLOPES 3: 1 L A TOP OF DITCH B3:12"-4" ROCK 24" MIN. BOTTOM AND SIDES OF THE DITCH ROCK MUST COMPLETELY COVER THE 6" MIN. EMERGENCY OVERFLOW SPILLWAY 4"-8" QUARRY SPALLS GEOTEXTILE 12" MIN. THICKNESS EXIST I N G R O A D R = 25' MIN. INGRESS/EGRESS AREA PROVIDE FULL WIDTH OF 20' MI N. RUNOFF DRAINS OFF THE PAD ENTRANCE BE CROWNED SO THAT IT IS RECOMMENDED THAT THE100' 1.QUARRY SPALLS (OR HOG FUEL) SHALL BE ADDED IF THE PAD IS NO LONGER IN ACCORDANCE WITH THE SPECIFICATIONS. 2.IF THE ENTRANCE IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT, THEN ALTERNATIVE MEASURES TO KEEP THE STREETS FREE OF SEDIMENT SHALL BE USED. THIS MAY INCLUDE STREET SWEEPING, AN INCREASE IN THE DIMENSIONS OF THE ENTRANCE, OR THE INSTALLATION OF A WHEEL WASH. IF WASHING IS USED, IT SHALL BE DONE ON AN AREA COVERED WITH CRUSHED ROCK, AND WASH WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND. 3.ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING. THE SEDIMENT COLLECTED BY SWEEPING SHALL BE REMOVED OR STABILIZED ON-SITE. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DOWN THE STREET, EXCEPT WHEN SWEEPING IS INEFFECTIVE AND THERE IS A THREAT TO PUBLIC SAFETY. IF IT IS NECESSARY TO WASH THE STREETS, THE CONSTRUCTION OF A SMALL SUMP SHALL BE CONSIDERED. THE SEDIMENT WOULD THEN BE WASHED INTO THE SUMP. 4.ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAD AND END UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY. 5.IF VEHICLES ARE ENTERING OR EXITING THE SITE AT POINTS OTHER THAN THE CONSTRUCTION ENTRANCE(S), FENCING SHALL BE INSTALLED TO CONTROL TRAFFIC. MAINTENANCE STANDARDS PROVIDE DIP CULVERT FOR TEMPORARY CONTROL OF DRAINAGE. NOTES: 1.FILTERS SHALL BE i NSPECTED AFTER EACH STORM EVENT AND CLEANED OR REPLACED WHEN 1/3 FULL. 2.INSTALL INLET PROTECTION IN ALL NEW STORM STRUCTURES THAT WILL COLLECT STORMWATER AS THEY ARE INSTALLED. ADAPTOR SKIRT RETRIEVAL STRAP OVERFLOW (TO BYPASS PEAK STORM VOLUMES) EXISTING CATCH BASIN SEDIMENT ACCUMULATION GEOTEXTILE FABRIC 24"36"48" 1 NOT TO SCALE INLET SEDIMENT PROTECTION 2 NOT TO SCALE GRAVEL CHECK DAM 3 NOT TO SCALE CONSTRUCTION ENTRANCE 4 NOT TO SCALE EMERGENCY OVERFLOW SPILLWAY 5 NOT TO SCALE SEDIMENT POND SECTION 6 NOT TO SCALE SEDIMENT POND RISER 10/19/2021 1 2 3 4 TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 253.383.2572 FAX 28 SKML/EAML/EA 10/18/2021 CIVIL PERMIT SET 2210016.10 PO BOX 597 PUYALLUP, WA 98371 JERRY SCHUUR SCHUUR BROTHERS CONSTRUCTION TAHOMA BOULEVARD APARTMENTS A PORTION OF THE NW 1/4 OF THE SE 1/4 OF SEC. 24, TWN. 17 N., RGE. 01 E. W.M. CITY OF YELM, THURSTON COUNTY, WASHINGTON. TAHOMA BOULEVARD APARTMENTS DATE: September 9, 2021 FILENAME: Q:\2021\2210016\10_CIV\CAD\_Site Development\2210016-SH-TESC.dwg C1.2 5 TESC NOTES AND DETAILS 1.THE FILTER FABRIC SHALL BE PURCHASED IN A CONTINUOUS ROLL CUT TO THE LENGTH OF THE BARRIER TO AVOID USE OF JOINTS. WHEN JOINTS ARE NECESSARY, FILTER CLOTH SHALL BE SPLICED TOGETHER ONLY AT A SUPPORT POST WITH A MINIMUM SIX-INCH OVERLAP, AND BOTH ENDS SECURELY FASTENED TO THE POST. 2.THE FILTER FABRIC FENCE SHALL BE INSTALLED TO FOLLOW THE CONTOURS (WHERE FEASIBLE). THE FENCE POSTS SHALL BE SPACED A MAXIMUM OF SIX FEET APART AND DRIVEN SECURELY INTO THE GROUND (MINIMUM OF 30") 3.A TRENCH SHALL BE EXCAVATED, ROUGHLY EIGHT INCHES WIDE AND TWELVE INCHES DEEP, UPSLOPE AND ADJACENT TO THE WOOD POST TO ALLOW THE FILTER FABRIC TO BE BURIED. 4.WHEN STANDARD STRENGTH FILTER FABRIC IS USED, A WIRE MESH SUPPORT FENCE SHALL BE FASTENED SECURELY TO THE UPSLOPE SIDE OF THE POSTS USING HEAVY-DUTY WIRE STAPLES AT LEAST ONE INCH LONG, TIE WIRES, OR HOG RINGS. THE WIRE SHALL EXTEND INTO THE TRENCH A MINIMUM OF FOUR INCHES AND SHALL NOT EXTEND MORE THAN THIRTY SIX INCHES ABOVE THE ORIGINAL GROUND SURFACE. 5.THE STANDARD STRENGTH FILTER FABRIC SHALL BE STAPLED OR WIRED TO THE FENCE, AND TWENTY INCHES OF THE FABRIC SHALL BE EXTENDED INTO THE TRENCH. THE FABRIC SHALL NOT EXTEND MORE THAN THIRTY SIX INCHES ABOVE THE ORIGINAL GROUND SURFACE. FILTER FABRIC SHALL NOT BE STAPLED TO EXISTING TREES. 6.WHEN EXTRA-STRENGTH FILTER FABRIC AND CLOSER POST SPACING ARE USED, THE WIRE MESH SUPPORT FENCE MAY BE ELIMINATED. IN SUCH A CASE, THE FILTER FABRIC IS STAPLED OR WIRED DIRECTLY TO THE POSTS WITH ALL OTHER PROVISIONS OF STANDARD NOTE (S) APPLYING. 7.THE TRENCH SHALL BE BACKFILL WITH 3/4 INCH MINIMUM DIAMETER WASHED GRAVEL. 8.FILTER FABRIC FENCES SHALL BE REMOVED WHEN THEY HAVE SERVED THEIR USEFUL PURPOSE, BUT NOT BEFORE THE UPSLOPE AREA HAS BEEN PERMANENTLY STABILIZED. 9.FILTER FABRIC FENCES SHALL BE INSPECTED IMMEDIATELY AFTER EACH RAINFALL AND AT LEAST DAILY DURING PROLONGED RAINFALL. ANY REQUIRED REPAIRS SHALL BE MADE IMMEDIATELY. 10.CONTRIBUTING LENGTH TO FENCE SHALL NOT BE MORE THAN 100 FEET. 11.DO NOT INSTALL BELOW AN OUTLET PIPE OR WEIR. 12.DO NOT DRIVE OVER OR FILL OVER FILTER FABRIC FENCE. SIDE VIEW NOTES: FRONT VIEW CHAINLINK FENCE 8" 2.0' MIN.5.0'1.0'2.0'0.5'6' MAX. 5.0' 2.0' 2.5' 2" X 4" WOOD POSTS, STANDARD OR BETTER, OR STEEL FENCE POST BURY BOTTOM OF FILTER MATERIAL IN 8"X12" TRENCH 2" X 4" BY 14 GA. WIRE FABRIC OR EQUIVALENT EXISTING GRADE ORANGE FILTER FABRIC MATERIAL 60" WIDE ROLLS - USE RINGS TO ATTACH ATTACH TO WIRE FABRIC 2" X 4" WOOD POST OR STEEL FENCE POST PROVIDE 3/4" - 1 1/2" WASHED GRAVEL BACKFILL IN TRENCH AND ON BOTH SIDES OF FILTER FENCE FABRIC ON THE SURFACE 2" X 2" BY 14 GA. WIRE FABRIC OR EQUIVALENT, AFFIX TO POST FILTER FABRIC MATERIAL MIRAFI 100 NS OR EQUIVALENT 1 NOT TO SCALE SILTATION FENCE 10/19/2021 5.00' SIDEWALK 1.50' 24' ASPHALT RAISED EDGE CURB (5,250 SF) (9,700 SF) (10,360 SF)(10,360 SF) R20.0' R2.5' R2.5' R2.5'R2.5'R2.5'R20.0' R2.5' R2.5' R20.0' R2.5'R2.5'R2.5'R2.5' R20.0' R2.5' R2.5' R2.5' R20.0' R46.0' R20.0' R2.5' R2.5' R20.0' R2.5'R2.5'R2.5'R2.5'R20.0' R2.5' R2.5' R2.5' R18' R18' R18' R20.0' EC ECEC ECECECEC EC EC EC ECECECECECECEC ECEC EC EC EC ECECECECECECNCNC NC NC NC NC NCNCNCNCNCNCNCNCSTORMWATER TREATMENT VAULT (5) 16 UNIT CBU MAILBOX CLUSTER CONTRACTOR TO COORDINATE FINAL LOCATION WITH USPS R2.50' RAMP LANDING EC R40.00' R10.00' R44.00' R16.00' FUTURE CURB TO BE PROVIDED WHEN FINAL CONNECTIONS TO ROAD A ARE MADE AND THE TEMPORARY ACCESS IS REMOVED PROPSOED STEP TANK LOCATION(S) (TYP) S1° 30' 17"W 596.42' S1° 30' 43"W 1323.42'N88° 14' 50"W1326.63'N88° 13' 17"W199.33'L=152.82'R=547.00'Δ=16°00'26"26.00' 26.00' XX X X VARIES 39.12' EC R2.50'R2.50'R2.50' R2.50' CONCRETE SURFACING STANDARD DUTY ASPHALT PAVEMENT EXTRUDED CURB EC NO CURB NC CHANGE IN CURB TYPE X CONCRETE WHEELSTOP LEGEND 1 2 3 4 TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 253.383.2572 FAX 28 SKML/EAML/EA 10/18/2021 CIVIL PERMIT SET 2210016.10 PO BOX 597 PUYALLUP, WA 98371 JERRY SCHUUR SCHUUR BROTHERS CONSTRUCTION TAHOMA BOULEVARD APARTMENTS A PORTION OF THE NW 1/4 OF THE SE 1/4 OF SEC. 24, TWN. 17 N., RGE. 01 E. W.M. CITY OF YELM, THURSTON COUNTY, WASHINGTON. TAHOMA BOULEVARD APARTMENTS DATE: October 18, 2021 FILENAME: Q:\2021\2210016\10_CIV\CAD\_Site Development\2210016-SH-CNTRL.dwg C2.0 6 HORIZONTAL CONTROL AND SURFACING PLANNGRAPHIC SCALE 0 30 60 1" = 30 FEET 15 20.00' (TYP) 26' 20.00'26'20' 20.00' 26' 20.00'26'20' 5' 9.00' (TYP) 9' (TYP) 9' (TYP) 20.00' 26' 26'20' 5' 26.00' 19' VARIES (8.5±) 30.00' VARIES VARIES 74.75' 89.02' 74.75' 74.75' 167.19' 74.75' BLDG 1 BLDG 2 BLDG 3 BLDG 4 ACCESSIBLE PARKING STALLS 5' SIDEWALK (TYP) 5.00' 8' SIDEWALK 8' SIDEWALK 11.13'12.67' 21.79' 11.13' INFILTRATION GALLERY 2,520 SF FOOTPRINT (126' X 20' X 4') TRASH ENCLOSURE. REFER TO ARCHITECTURAL PLANS TRASH ENCLOSURE. REFER TO ARCHITECTURAL PLANS ROAD A ACCESSIBLE PARKING STALLS ACCESSIBLE PARKING STALLS 5' SIDEWALK TAHOMA BLVD.20.00' (TYP) PARKING NOTES NUMBER OF PARKING STALLS REQUIRED: 137 1-2 BED UNITS: 62 (93 STALLS) 3 BED UNITS: 18 (36 STALLS) TOTAL UNITS: 80 (8 GUEST STALLS) NUMBER OF PARKING STALLS PROVIDED: 180 NUMBER OF ADA STALLS: 8 1.ALL STALLS TO BE 9' W X 20' L UNLESS NOTED OTHERWISE 2.CONCRETE WHEELSTOPS TO BE PROVIDED WHERE STALLS ARE ADJACENT TO FLUSH CURB OR NO CURB 8.40' 11 10 11 10 10 10 10 10 20 9 2020 20 9 OPEN SPACE NAD 1983/11 WASHINGTON STATE PLANE SOUTH PROJECTION, BASED ON GPS OBSERVATIONS USING WSRN AND GEOID 2012A. UNITS OF MEASUREMENT ARE US SURVEY FEET. BASIS OF BEARING (BY OTHERS) 23.65' 8.00' 7.68' 39.33' 30.00' 1 C2.1 4 C2.1 3 C2.1 5 C2.1 5 C2.1 5 C2.1 6 C2.1 1 C2.2 TEMPORARY ACCESS TO BERRY AVE. REMOVE ACCESS AND RESTORE TO ORIGINAL CONDITION ONCE FINAL CONNECTIONS TO ROAD A ARE MADE. SAW CUT AS NEEDED TO PROVIDE TEMP. ACCESS BERRY AVE.5.00' MIN 7 C2.1 5 C2.1 ACCESSIBLE PARKING STALLS VAN ACCESSIBLE STALL VAN ACCESSIBLE STALL VAN ACCESSIBLE STALL VAN ACCESSIBLE STALL 10/19/2021 9.00'9.00'9.00' 20.00' 1 2 3 4 TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 253.383.2572 FAX 28 SKML/EAML/EA 10/18/2021 CIVIL PERMIT SET 2210016.10 PO BOX 597 PUYALLUP, WA 98371 JERRY SCHUUR SCHUUR BROTHERS CONSTRUCTION TAHOMA BOULEVARD APARTMENTS A PORTION OF THE NW 1/4 OF THE SE 1/4 OF SEC. 24, TWN. 17 N., RGE. 01 E. W.M. CITY OF YELM, THURSTON COUNTY, WASHINGTON. TAHOMA BOULEVARD APARTMENTS DATE: October 18, 2021 FILENAME: Q:\2021\2210016\10_CIV\CAD\_Site Development\2210016-SH-CNTRL.dwg C2.1 7 SURFACING NOTES AND DETAILS 2" 4" NOTES: 1.ALL DEPTHS SHOWN ARE COMPACTED DEPTHS. 2.THE CONTRACTOR SHALL EXPOSE EXISTING SUBGRADE, PROOF ROLL AND COMPACT TO 95%. IF YIELDING CONDITIONS ARE ENCOUNTERED, YIELDING MATERIALS SHALL BE REPLACED WITH IMPORTED STRUCTURAL FILL MATERIAL. THE DEPTH OF MATERIAL REPLACEMENT SHALL BE DETERMINED BY THE GEOTECHNICAL ENGINEER. CRUSHED SURFACING BASE COURSE PER WSDOT 9.03-9(3) HMA CLASS 1/2", PG 64-22 6"10" 5"2.5"CURB, WSDOT SPEC. 8-04 CEMENT CONCRETE FOR FILL BEHIND CURBS SEE LANDSCAPE PLAN6"2.5"CUT/SAWED JOINT BOTTOM OF @ 15' INTERVAL 1"0.02 FT/FT COMPACTED SUBGRADE PER PLAN NOTES: 4" CEMENT CONCRETE SIDEWALK 2" CRUSHED SURFACING TOP COURSE 1.CEMENT CONCRETE SHALL BE CLASS B 3000. 2.COMPACTION FOR CONCRETE WALKS TO BE 95% MAXIMUM DENSITY. 3.EXPANSION JOINTS CONSISTING OF 3/8" BY 4" PREMOLDED JOINT MATERIAL SHALL BE PLACED AT 15 FOOT INTERVALS, OR AS DIRECTED BY THE ARCHITECTURAL PLANS. 1/4" EDGE GROOVE SHALL BE PROVIDED AT JOINT EDGES. 4.SEE ARCHITECTURAL PLANS FOR JOINT PATTERNS. 1/4" EDGED GROOVE 24" MIN. DEPTH STRUCTURAL FILL COMPACTED TO 95% ` RAMP 3/16"1 5/8"2 3/8" 5/8" 7/16" 7/8"1 7/16" 3/4" 1 1/2" C D A B A B A B C D MIN MAX DETECTABLE WARNING PATTERN AREA SHALL BE YELLOW, IN COMPLIANCE WITH WSDOT STANDARD SPEC. 8-14.3(3) N NOTE: ACCESSIBLE PARKING AREA SHALL NOT EXCEED 2% SLOPE IN ANY DIRECTION ACCESSIBLE PARKING SIGNAGE AND SYMBOLS (TYP) 5.00' DETECTABLE WARNING SURFACE (TYP) 1 NOT TO SCALE CEMENT CONCRETE SIDEWALK 2 NOT TO SCALE DETECTABLE WARNING SURFACE 3 NOT TO SCALE EXTRUDED CURB 4 NOT TO SCALE PAVEMENT SECTION 5 NOT TO SCALE ACCESSIBLE PARKING 6 NOT TO SCALE MAILBOX CLUSTER 2 C2.1 2 C2.2 7 NOT TO SCALE ASPHALT RAISED EDGE CURB 10/19/2021 1 2 3 4 TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 253.383.2572 FAX 28 SKML/EAML/EA 10/18/2021 CIVIL PERMIT SET 2210016.10 PO BOX 597 PUYALLUP, WA 98371 JERRY SCHUUR SCHUUR BROTHERS CONSTRUCTION TAHOMA BOULEVARD APARTMENTS A PORTION OF THE NW 1/4 OF THE SE 1/4 OF SEC. 24, TWN. 17 N., RGE. 01 E. W.M. CITY OF YELM, THURSTON COUNTY, WASHINGTON. TAHOMA BOULEVARD APARTMENTS DATE: October 18, 2021 FILENAME: Q:\2021\2210016\10_CIV\CAD\_Site Development\2210016-SH-CNTRL.dwg C2.2 8 SURFACING NOTES AND DETAILS PROPOSED GRADE R7-8a SIGN AT VAN ACCESSIBLE STALL 2500 PSI CONCRETE 2" DIA. G.I.P. SCH. 40 R7-8A R7-801 11/97 DIMENSIONS (INCHES) A B C D E F G H J K L 12 18 3/8 5/8 2C 3/4C 1 1/2 3/4 6 1 1/2 COLORS: LEGEND - GREEN (REFL) SYMBOL - BLUE (REFL) BACKGROUND - WHITE (REFL) 6"7"3"2'-10"11"10" NOTES: 1.CONCRETE FOOTING SHALL BE 1'Ø x 2' DEEP WITH TOP OF FOOTING 3" BELOW FINISHED GRADE. 3" WIDE PAINT STRIP TRAFFIC LINE WHITE PROVIDE SYMBOL IN ALL ADA ACCESSIBLE PARKING STALLS ATTACHMENT DETAIL ELEVATION PLAN NOTE: SET WHEEL STOP 9" FROM ASPHALT EDGE PER 5"1" 12" MIN. 3:1 SAND AND CEMENT GROUT 1" DEPTH 2 NOT TO SCALE ACCESSIBLE PARKING SIGNAGE AND SYMBOLS1NOT TO SCALE CONCRETE WHEELSTOP 10/19/2021 BLDG 1 BLDG 2 BLDG 3 BLDG 4 346 349 346346345348S1° 30' 43"W 641.71'S88° 14' 50"E344.86'S1° 30' 17"W 596.42' N88° 13' 17"W 199.33' Δ=16°00'26" R=547.00' L=152.82' CB# 1 RIM: 348.19 CB# 3 RIM: 348.73 CB# 4 RIM: 348.12 CB# 14 RIM: 347.89 CB# 16 RIM: 346.29 CB# 5 RIM: 346.75 CB# 13 RIM: 346.75 CB# 9 RIM: 344.80 CB# 6 RIM: 345.61 CO# 3 RIM: 346.07 CO# 1 RIM: 344.11 CO# 2 RIM: 345.43 CB# 12 RIM: 345.61 CB# 7 RIM: 344.47 CB# 17 48" TYPE 2 RIM: 344.60 CB# 11 RIM: 344.47 CB# 8 STORMFILTER VAULT RIM: 341.54 FF: 349.10 FF: 347.75 FF: 347.56 FF: 346.50 FG: 348.72 FG: 349.42 FG: 348.18 FG: 347.40 FG: 347.14 FG: 345.57 FG: 345.32 FG: 349.12 FG: 349.25 FG: 348.72 FG: 348.90 FG: 349.42 FG: 349.47 FG: 350.85 FG: 349.50 FG: 349.50 FG: 351.86 FG: 349.46 FG: 347.19 FG: 346.55 FG: 346.25 FG: 344.70 FG: 345.16 FG: 345.32 FG: 345.23 FG: 347.40 FG: 346.82 FG: 345.58 FG: 347.65 FG: 347.59 FG: 347.59 FG: 347.40 FG: 347.40 FG: 346.52 FG: 346.42 FG: 346.34 FG: 346.42 FG: 346.88 FG: 345.00 CB# 2 RIM: 348.19 CB# 15 RIM: 346.29 CB# 10 RIM: 344.99 YD# 8 RIM: 346.26 RDCO# 25 RIM: 346.40 RDCO# 26 RIM: 346.43 RDCO# 27 RIM: 346.25 RDCO# 28 RIM: 346.50 RDCO# 29 RIM: 346.49 RDCO# 30 RIM: 346.45 RDCO# 31 RIM: 346.20 RDCO# 32 RIM: 346.37 RDCO# 33 RIM: 346.27 YD# 5 RIM: 345.79 RDCO# 34 RIM: 346.38 YD# 6 RIM: 345.75 RDCO# 35 RIM: 346.09 RDCO# 19 RIM: 347.27 RDCO# 20 RIM: 347.56 RDCO# 18 RIM: 347.34 RDCO# 16 RIM: 347.51 RDCO# 17 RIM: 347.56 RDCO# 21 RIM: 347.40 RDCO# 15 RIM: 347.55 RDCO# 14 RIM: 347.52 RDCO# 22 RIM: 347.54 RDCO# 23 RIM: 347.33 RDCO# 24 RIM: 347.56 RDCO# 13 RIM: 347.48 RDCO# 6 RIM: 347.71 RDCO# 5 RIM: 347.72 RDCO# 7 RIM: 347.75 RDCO# 3 RIM: 347.60 YD# 1 RIM: 346.99 RDCO# 2 RIM: 347.65 YD# 2 RIM: 346.86 RDCO# 1 RIM: 347.30 RDCO# 4 RIM: 347.74 RDCO# 8 RIM: 347.75 RDCO# 10 RIM: 347.57 YD# 3 RIM: 346.89 RDCO# 11 RIM: 347.61 RDCO# 12 RIM: 347.75 RDCO# 9 RIM: 347.71 RDCO# 42 RIM: 349.03 RDCO# 43 RIM: 348.97 RDCO# 41 RIM: 349.11 RDCO# 38 RIM: 348.92 RDCO# 37 RIM: 349.10 RDCO# 36 RIM: 349.07 RDCO# 39 RIM: 349.02 RDCO# 40 RIM: 349.18 RDCO# 44 RIM: 346.50 FG: 344.60 FG: 344.60 FG: 341.95 FG: 340.89 FG: 339.90 FG: 345.72 FG: 345.12FG: 346.10 FG: 346.19 FG: 346.20 FG: 346.28 FG: 346.55 FG: 346.89 FG: 346.89 FG: 347.22 FG: 347.26 FG: 347.48 FG: 347.59 FG: 347.21 FG: 347.59 FG: 347.24 FG: 347.17 FG: 347.40 FG: 347.40 FG: 347.14 FG: 345.93 FG: 346.34 FG: 346.04 FG: 347.03 FG: 346.17 FG: 345.94 FG: 346.17 FG: 345.96 FG: 344.63 FG: 347.22 FG: 346.84 FG: 346.84 FG: 346.54 FG: 348.34FG: 348.43 FG: 348.19 FG: 348.50 FG: 348.42 FG: 349.25 FG: 348.81 FG: 349.50 FG: 348.79 FG: 348.90 FG: 348.60 FG: 348.90 FG: 349.02 FG: 347.70 FG: 347.65 FG: 349.17 FG: 349.25 FG: 348.42 FG: 348.33 FG: 348.49 FG: 348.42 FG: 348.18 FG: 345.57 FG: 345.61 FG: 348.19 FG: 351.30 FG: 352.11 FG: 347.12 FG: 346.61 FG: 348.90 FG: 348.98 FG: 348.98 FG: 347.52 FG: 346.52 FG: 346.44 FG: 346.50 FG: 346.42 FG: 346.34 FG: 348.98 FG: 348.99 FG: 348.81 FG: 348.80 FG: 351.58 FG: 350.59 FG: 347.39 FG: 347.00 FG: 347.67 FG: 347.67 FG: 347.68347 347348FG: 347.70 FG: 347.46 FG: 347.46 FG: 346.04 FG: 346.34 109 LF 12" CPEP @ 0.50% 54 LF 12" CPEP @ 0.50% 137 LF 12" CPEP @ 0.50% 137 LF 12" CPEP @ 0.50%72 LF 12"CPEP @ 0.50%51 L F 8 " CP E P @ 1 . 4 0 % 49 LF 8" CPEP @ 1.72% 114 LF 12" CPEP @ 0.50% 114 LF 12" CPEP @ 0.78% 34 LF 12" CPEP @ 3.10%34 LF 12" CPEP @ 0.50% 16 LF 12" CPEP @ 0.50%194 LF 12" CPEP @ 0.50%47 LF 12" CPEP @ 0.50% 114 LF 12" CPEP @ 0.50% 114 LF 12" CPEP @ 0.50%72 LF 12" CPEP @ 0.50%46 LF 8 " CPEP @ 1 . 5 4 % 48 L F 8 " CP E P @ 1 . 7 2 % 114 LF 12" DI CL52 @ 0.50%56 LF 8" CPEP @ 0.50% 47 LF 12" CPEP @ 0.50% 45 LF 12" CPEP @ 0.62% 49 LF 8" CPEP @ 1.42% 54 LF 8" CPEP @ 0.50% FG: 348.72 FG: 348.72 FG: 349.50 FG: 348.73 FG: 349.12 FG: 344.86 FG: 347.04 YD# 4 RIM: 346.65 YD# 7 RIM: 347.11 47 LF 8" CPEP @ 0.50%44 LF 8" CPEP @ 0.50% RD #(2) RD #(3)RD #(4)RD #(5)RD #(6) RD #(1) RD #(7) RD #(8) RD #(15) RD #(14) RD #(13) RD #(12) RD #(11) RD #(9) RD #(10) RD #(19) RD #(20) RD #(21) RD #(30) RD #(31) RD #(28) RD #(18) RD #(17) RD #(23) RD #(24) RD #(22) RD #(25) RD #(27) RD #(39) RD #(38) RD #(37) RD #(36) RD #(35) RD #(34) RD #(32) RD #(33) RD #(29) 345 3453453453453 4 5 350 3 4 6 346346346 3 4 7 3473483 4 83493 4 9 3 4 9 351 351352345343344347347347FG: 345.30 FG: 344.00 FG: 340.57 FG: 342.16 344343342341SEE GRADING ENLARGEMENT THIS SHEET FG: 346.52 FG: 346.54 RAMP SLOPE 7.20% FG: 347.52 FG: 346.52 FG: 346.55 RAMP SLOPE 7.20% FG: 346.85 FG: 345.95 FG: 345.91 FG: 345.01 4.67' 10.00' 5.00' 2.85' 13.00' 5.00' 14.20' FG: 344.04 FG: 345.00 FG: 344.94 FG: 344.87 FG: 344.87 FG: 344.12 FG: 344.12 FG: 344.09 FG: 344.09 FG: 343.07 FG: 343.07 FG: 343.07 FG: 343.12 FG: 341.98 FG: 341.96 7. 5 0 % 7.63%7.54%1 2 3 4 TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 253.383.2572 FAX 28 SKML/EAML/EA 10/18/2021 CIVIL PERMIT SET 2210016.10 PO BOX 597 PUYALLUP, WA 98371 JERRY SCHUUR SCHUUR BROTHERS CONSTRUCTION TAHOMA BOULEVARD APARTMENTS A PORTION OF THE NW 1/4 OF THE SE 1/4 OF SEC. 24, TWN. 17 N., RGE. 01 E. W.M. CITY OF YELM, THURSTON COUNTY, WASHINGTON. TAHOMA BOULEVARD APARTMENTS DATE: October 5, 2021 FILENAME: Q:\2021\2210016\10_CIV\CAD\_Site Development\2210016-SH-GRAD.dwg C3.0 9 GRADING AND DRAINAGE PLAN 3H:1V MAX SLOPE INFILTRATION GALLERY 2,540 SF FOOTPRINT (127' X 20' X 4') 127 LF 12" PERF PVC @ 0.0% 10' O.C GRADE BREAK (TYP)NGRAPHIC SCALE 0 30 60 1" = 30 FEET 15 ROAD A TAHOMA BLVDEARTHWORK QUANTITIES NAVD 1988 VERTICAL DATUM ON ORTHOMETRICALLY CORRECTED GPS OBSERVATIONS USING WSRN AND GEOID 2012A. VERTICAL DATUM (BY OTHERS) CUT = 3,070 CUBIC YARDS FILL = 2,860 CUBIC YARDS NET = 210 CUBIC YARDS (EXPORT) NOTES: THE ABOVE QUANTITIES ARE ESTIMATES ONLY INTENDED FOR THE PERMITTING PROCESS. DO NOT USE FOR BID PURPOSES. THE QUANTITIES DO NOT HAVE STRIPPING, COMPACTION, OR CUT AND FILL ADJUSTMENT FACTORS APPLIED TO THEM, NOR DO THEY ACCOUNT FOR PAVEMENT, SIDEWALK OR BUILDING SECTIONS. NO WORK SHALL OCCUR WEST OF PROPERTY LINE UNTIL RIGHT-OF-WAY IS DEDICATED TO THE CITY OF YELM 1 C3.3 1 C3.3 2 C3.3 2 C3.3 3 C3.3 4 C3.3 STORM NOTES 1.BMP T5.13 POST CONSTRUCTION SOIL QUALITY AND DEPTH TO BE APPLIED AT ALL DEVELOPED, NON STRUCTURAL, LAWN AND LANDSCAPE AREAS ON ALL LOTS AND TRACTS. IMPLEMENTATION OF BMP T5.13 ON INDIVIDUAL LOTS SHALL BE CONDUCTED IN CONJUNCTION WITH FINISH LANDSCAPING DURING BUILD-OUT PHASE OF EACH LOT. 2.ALL STORM PIPE TO BE CPEP UNLESS OTHERWISE NOTED. 3.MINIMUM SLOPE FOR ALL STORM LINES IS TO BE 0.50% UNLESS OTHERWISE NOTED. 4.REFER TO SHEET C3.1 FOR STRUCTURE RIM AND INVERT INFORMATION 1 C3.4 2 C3.4 BERRY AVE1 SCALE: 1"=10' PEDESTRIAN RAMP N 1 C3.0 10/19/2021 STORM STRUCTURE TABLE STRUCTURE NAME CB# 1 TYPE 1 N 594352.62 E 1110857.01 CB# 2 TYPE 1 N 594349.75 E 1110965.61 CB# 3 TYPE 1 N 594348.31 E 1111019.91 CB# 4 TYPE 1 N 594485.75 E 1111023.54 CB# 5 TYPE 1 N 594623.19 E 1111027.16 CB# 6 TYPE 1 N 594737.14 E 1111030.17 CB# 7 TYPE 1 N 594850.64 E 1111033.17 CB# 8 STORM FILTER VAULT N 594884.20 E 1111034.05 CB# 9 TYPE 1 N 594885.10 E 1110999.84 CB# 10 TYPE 1 N 594890.18 E 1110806.41 CB# 11 TYPE 1 N 594858.06 E 1110772.56 CB# 12 TYPE 1 N 594744.02 E 1110769.58 CB# 13 TYPE 1 N 594630.06 E 1110766.56 CB# 14 TYPE 1 N 594516.10 E 1110763.52 CB# 15 TYPE 1 N 594628.17 E 1110838.20 CB# 16 TYPE 1 N 594625.08 E 1110955.52 CB# 17 48" TYPE 2 N 594903.82 E 1111029.54 CO# 1 CO N 594913.82 E 1111029.78 CO# 2 CO N 594917.28 E 1110897.61 CO# 3 CO N 594907.30 E 1110897.25 STRUCTURE DETAILS RIM = 348.19 IE = 345.12 (12" E) RIM = 348.19 IE = 344.58 (12" W) IE = 344.58 (12" E) IE = 344.91 (8" N) RIM = 348.73 IE = 344.31 (12" W) IE = 344.31 (12" N) RIM = 348.12 IE = 343.62 (12" N) IE = 343.62 (12" S) IE = 343.62 (12" W) RIM = 346.75 IE = 342.93 (12" S) IE = 342.93 (12" N) IE = 342.93 (12" W) RIM = 345.61 IE = 342.36 (12" S) IE = 342.36 (12" N) IE = 342.36 (12" W) RIM = 344.47 IE = 341.47 (12" S) IE = 341.47 (12" N) RIM = 341.54 IE = 340.43 (12" S) IE = 340.42 (12" W) RIM = 344.80 IE = 340.59 (12" W) IE = 340.59 (12" E) IE = 340.92 (8" S) RIM = 344.99 IE = 341.56 (12" SW) IE = 341.56 (12" E) IE = 341.89 (8" SE) RIM = 344.47 IE = 341.79 (12" S) IE = 341.79 (12" NE) RIM = 345.61 IE = 342.36 (12" N) IE = 342.36 (12" S) IE = 342.36 (12" E) RIM = 346.75 IE = 342.93 (12" N) IE = 342.93 (12" S) IE = 342.93 (12" E) RIM = 347.89 IE = 343.83 (8" E) IE = 343.50 (12" N) RIM = 346.29 IE = 343.29 (12" W) IE = 343.62 (8" S) IE = 343.62 (8" NE) RIM = 346.29 IE = 343.62 (8" S) IE = 343.29 (12" E) IE = 343.62 (8" N) RIM = 344.60 IE = 337.30 (12" S) IE = 337.30 (12" N) IE = 337.30 (12" W) RIM = 344.11 IE = 337.30 (12" S) IE = 337.30 (12" W) RIM = 345.43 IE = 337.30 (12" E) RIM = 346.07 IE = 337.30 (12" E) STORM STRUCTURE TABLE STRUCTURE NAME RDCO# 1 CO N 594511.23 E 1110891.61 RDCO# 2 CO N 594512.24 E 1110853.25 RDCO# 3 CO N 594515.13 E 1110819.19 RDCO# 4 CO N 594579.21 E 1110893.39 RDCO# 5 CO N 594585.23 E 1110855.36 RDCO# 6 CO N 594579.11 E 1110820.87 RDCO# 7 CO N 594547.16 E 1110818.53 RDCO# 8 CO N 594578.06 E 1110936.84 RDCO# 9 CO N 594575.17 E 1110970.90 RDCO# 10 CO N 594510.09 E 1110935.05 RDCO# 11 CO N 594511.19 E 1110969.22 RDCO# 12 CO N 594543.14 E 1110971.56 RDCO# 13 CO N 594679.62 E 1110823.51 RDCO# 14 CO N 594671.03 E 1110859.00 RDCO# 15 CO N 594675.35 E 1110903.32 RDCO# 16 CO N 594675.46 E 1110982.77 RDCO# 17 CO N 594673.74 E 1110950.69 RDCO# 18 CO N 594742.66 E 1110951.45 RDCO# 19 CO N 594738.82 E 1110986.38 RDCO# 20 CO N 594707.57 E 1110986.52 STRUCTURE DETAILS RIM = 347.30 IE = 344.44 (8" S) RIM = 347.65 IE = 344.61 (8" W) RIM = 347.60 IE = 344.44 (8" E) IE = 344.44 (8" S) RIM = 347.74 IE = 344.52 (8" W) RIM = 347.72 IE = 344.33 (8" E) IE = 344.33 (8" W) IE = 344.33 (8" N) RIM = 347.71 IE = 344.50 (8" E) IE = 344.50 (8" S) RIM = 347.75 IE = 344.66 (8" N) RIM = 347.75 IE = 344.33 (8" E) IE = 344.33 (8" N) RIM = 347.71 IE = 344.50 (8" W) IE = 344.50 (8" S) RIM = 347.57 IE = 344.23 (8" E) RIM = 347.61 IE = 344.06 (8" W) IE = 344.06 (8" S) RIM = 347.75 IE = 344.66 (8" N) RIM = 347.48 IE = 344.61 (8" E) RIM = 347.52 IE = 344.44 (8" W) IE = 344.44 (8" SW) IE = 344.44 (8" E) RIM = 347.55 IE = 344.63 (8" W) RIM = 347.51 IE = 344.63 (8" W) RIM = 347.56 IE = 344.46 (8" E) IE = 344.46 (8" S) RIM = 347.34 IE = 342.85 (8" E) RIM = 347.27 IE = 342.68 (8" W) IE = 342.68 (8" S) IE = 342.68 (8" N) RIM = 347.56 IE = 342.84 (8" N) STORM STRUCTURE TABLE STRUCTURE NAME RDCO# 21 CO N 594743.58 E 1110905.56 RDCO# 22 CO N 594744.70 E 1110859.35 RDCO# 23 CO N 594743.60 E 1110825.19 RDCO# 24 CO N 594711.65 E 1110822.85 RDCO# 25 CO N 594776.12 E 1110826.04 RDCO# 26 CO N 594808.15 E 1110825.38 RDCO# 27 CO N 594840.10 E 1110827.72 RDCO# 28 CO N 594841.20 E 1110861.89 RDCO# 29 CO N 594839.91 E 1110907.73 RDCO# 30 CO N 594844.57 E 1110949.09 RDCO# 31 CO N 594837.33 E 1110987.29 RDCO# 32 CO N 594803.98 E 1110988.76 RDCO# 33 CO N 594772.71 E 1110986.10 RDCO# 34 CO N 594770.96 E 1110952.14 RDCO# 35 CO N 594772.22 E 1110898.46 RDCO# 36 CO N 594398.65 E 1110884.71 RDCO# 37 CO N 594431.30 E 1110883.09 RDCO# 38 CO N 594465.20 E 1110887.00 RDCO# 39 CO N 594390.45 E 1110930.16 RDCO# 40 CO N 594396.80 E 1110965.97 STRUCTURE DETAILS RIM = 347.40 IE = 343.25 (8" N) RIM = 347.54 IE = 344.32 (8" W) RIM = 347.33 IE = 344.15 (8" E) IE = 344.15 (8" W) IE = 344.15 (8" S) RIM = 347.56 IE = 344.31 (8" N) RIM = 346.40 IE = 343.57 (8" S) IE = 343.57 (8" E) RIM = 346.43 IE = 342.32 (8" N) RIM = 346.25 IE = 342.16 (8" S) IE = 342.16 (8" E) IE = 342.16 (8" NW) RIM = 346.50 IE = 342.33 (8" W) RIM = 346.49 IE = 342.01 (8" E) RIM = 346.45 IE = 341.79 (8" W) IE = 341.79 (8" E) RIM = 346.20 IE = 341.62 (8" S) IE = 341.62 (8" N) IE = 341.62 (8" W) RIM = 346.37 IE = 341.78 (8" N) RIM = 346.27 IE = 343.77 (8" W) IE = 343.77 (8" S) RIM = 346.38 IE = 343.94 (8" E) RIM = 346.09 IE = 343.15 (8" S) RIM = 349.07 IE = 345.56 (8" E) RIM = 349.10 IE = 344.83 (8" N) RIM = 348.92 IE = 344.66 (8" S) IE = 344.66 (8" E) RIM = 349.02 IE = 345.33 (8" E) IE = 345.33 (8" W) RIM = 349.18 IE = 345.15 (8" W) IE = 345.15 (8" S) STORM STRUCTURE TABLE STRUCTURE NAME RDCO# 41 CO N 594428.97 E 1110968.24 RDCO# 42 CO N 594461.30 E 1110968.12 RDCO# 43 CO N 594469.93 E 1110932.40 RDCO# 44 CO N 594773.23 E 1110860.10 YD# 1 TYPE 1 N 594508.64 E 1110819.20 YD# 2 TYPE 1 N 594507.16 E 1110891.65 YD# 3 TYPE 1 N 594505.57 E 1110968.83 YD# 4 TYPE 1 N 594747.19 E 1110986.38 YD# 5 TYPE 1 N 594766.46 E 1110985.34 YD# 6 TYPE 1 N 594768.15 E 1110898.48 YD# 7 TYPE 1 N 594743.77 E 1110816.29 YD# 8 TYPE 1 N 594770.33 E 1110826.08 STRUCTURE DETAILS RIM = 349.11 IE = 344.41 (8" N) RIM = 349.03 IE = 344.25 (8" S) IE = 344.25 (8" N) IE = 344.25 (8" W) RIM = 348.97 IE = 344.43 (8" E) IE = 344.43 (8" W) RIM = 346.50 IE = 343.74 (8" W) RIM = 346.94 IE = 344.41 (8" N) IE = 344.11 (8" W) RIM = 346.86 IE = 344.42 (8" N) IE = 344.42 (8" E) RIM = 346.89 IE = 344.03 (12" E) IE = 344.03 (8" W) IE = 344.03 (8" S) IE = 344.03 (8" N) RIM = 346.65 IE = 342.64 (12" E) IE = 342.64 (8" S) IE = 342.64 (8" N) RIM = 345.79 IE = 343.74 (8" N) IE = 342.74 (8" W) IE = 342.74 (8" S) RIM = 345.75 IE = 343.13 (8" N) IE = 343.13 (8" E) IE = 343.13 (8" S) RIM = 347.11 IE = 342.59 (12" W) IE = 342.59 (8" N) IE = 342.97 (8" E) RIM = 346.26 IE = 343.54 (8" S) IE = 343.54 (8" N) ROOF DRAIN PIPE TABLE NAME RD #(1) RD #(2) RD #(3) RD #(4) RD #(5) RD #(6) RD #(7) RD #(8) RD #(9) RD #(10) RD #(11) RD #(12) RD #(13) RD #(14) RD #(15) RD #(16) RD #(17) RD #(18) RD #(19) RD #(22) SIZE 8" 8" 8" 8" 8" 8" 8" 8" 8" 8" 8" 8" 8" 8" 8" 8" 8" 8" 8" 8" LENGTH 36.36' 46.19' 34.12' 45.65' 36.74' 32.32' 77.20' 34.18' 32.04' 34.18' 38.51' 35.03' 32.04' 6.49' 34.18' 4.07' 36.51' 44.54' 32.12' 34.18' SLOPE 0.50% 0.50% 0.50% 0.50% 0.50% 0.50% 0.50% 0.50% 0.50% 0.50% 0.50% 0.49% 0.50% 0.50% 0.50% 0.50% 0.47% 0.43% 0.53% 0.50% MATERIAL CPEP CPEP CPEP CPEP CPEP CPEP CPEP CPEP CPEP CPEP CPEP CPEP CPEP CPEP CPEP CPEP CPEP CPEP CPEP CPEP ROOF DRAIN PIPE TABLE NAME RD #(23) RD #(24) RD #(25) RD #(26) RD #(27) RD #(28) RD #(29) RD #(30) RD #(31) RD #(32) RD #(33) RD #(34) RD #(35) RD #(36) RD #(37) RD #(38) RD #(39) SIZE 8" 8" 8" 8" 8" 8" 8" 8" 8" 8" 8" 8" 8" 8" 8" 8" 8" LENGTH 32.04' 8.90' 28.30' 5.80' 34.18' 25.57' 86.88' 8.37' 19.30' 6.30' 34.01' 33.38' 38.89' 41.62' 34.18' 32.04' 4.07' SLOPE 0.50% 13.24% 3.36% -0.50% 0.50% 0.48% 0.45% 0.47% 0.50% 0.50% 0.50% 0.48% 0.44% 0.52% -0.50% 0.50% 0.50% MATERIAL CPEP CPEP CPEP CPEP CPEP CPEP CPEP CPEP CPEP CPEP CPEP CPEP CPEP CPEP CPEP CPEP CPEP 1 2 3 4 TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 253.383.2572 FAX 28 SKML/EAML/EA 10/18/2021 CIVIL PERMIT SET 2210016.10 PO BOX 597 PUYALLUP, WA 98371 JERRY SCHUUR SCHUUR BROTHERS CONSTRUCTION TAHOMA BOULEVARD APARTMENTS A PORTION OF THE NW 1/4 OF THE SE 1/4 OF SEC. 24, TWN. 17 N., RGE. 01 E. W.M. CITY OF YELM, THURSTON COUNTY, WASHINGTON. TAHOMA BOULEVARD APARTMENTS DATE: September 29, 2021 FILENAME: Q:\2021\2210016\10_CIV\CAD\_Site Development\2210016-SH-GRAD-DTLS.dwg C3.1 10 STORM TABLES RIM = 345.14 IE = 340.43 (12" S) IE = 340.43 (12" W) IE = 337.38 (12" N) 2 C3.4 YELM STORMWATER NOTES 11.THE MINIMUM STAKING OF STORM SEWER SYSTEMS SHALL BE IN ACCORDANCE WITH SECTION 3.00.050 OF THESE STANDARDS, AND AS FOLLOWS: A.STAKE LOCATION OF ALL CATCH BASINS, MANHOLES AND OTHER FIXTURES FOR GRADE AND ALIGNMENT. B.STAKE LOCATION, SIZE, AND DEPTH OF RETENTION/DETENTION FACILITY. C.STAKE FINISHED GRADE OF ALL STORMWATER FEATURES, INCLUDING BUT NOT LIMITED TO CATCH BASIN/MANHOLE RIM ELEVATIONS, OVERFLOW STRUCTURES, WEIRS, AND INVERT ELEVATIONS OF ALL PIPES IN CATCH BASINS, MANHOLES, AND PIPES THAT DAYLIGHT. 12.PIPE MATERIALS USED FOR STORMWATER CONVEYANCE SHALL BE AS APPROVED BY THE CITY. PIPE SIZE, SLOPE, COVER, ETC., SHALL BE AS SPECIFIED IN THE CITY OF YELM DEVELOPMENT GUIDELINES AND ENGINEERING STANDARDS. 13.ALL DRIVEWAY CULVERTS SHALL BE OF SUFFICIENT LENGTH TO PROVIDE A MINIMUM 3:1 SLOPE FROM THE EDGE OF THE DRIVEWAY TO THE BOTTOM OF THE DITCH. CULVERTS SHALL HAVE BEVELED END SECTIONS TO MATCH THE SIDE SLOPE. 14.IF DRAINAGE OUTLETS (STUB-OUTS) ARE TO BE PROVIDED FOR EACH INDIVIDUAL LOT, THE STUB OUTS SHALL CONFORM TO THE FOLLOWING: A.EACH OUTLET SHALL BE LOCATED AT THE LOWEST ELEVATION ON THE LOT, TO SERVICE ALL FUTURE ROOF DOWNSPOUTS AND FOOTING DRAINS, DRIVEWAYS, YARD DRAINS, AND ANY OTHER SURFACE OR SUBSURFACE. EACH OUTLET SHALL HAVE FREE-FLOWING, POSITIVE DRAINAGE TO AN APPROVED STORM WATER CONVEYANCE SYSTEM OR TO AN APPROVED OUTFALL LOCATION. B.OUTLETS ON EACH LOT SHALL BE LOCATED WITH A 5-FOOT HIGH, 2"X 4" STAKE MARKED "STORM" OR "DRAIN." THE STUB-OUT SHALL VISIBLY EXTEND ABOVE SURFACE LEVEL AND BE SECURED TO THE STAKE.PIPE MATERIAL SHALL BE AS APPROVED BY THE CITY. C.DRAINAGE EASEMENTS ARE REQUIRED FOR DRAINAGE SYSTEMS DESIGNED TO CONVEY FLOWS THROUGH INDIVIDUAL LOTS. D.THE DEVELOPER AND/OR CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE LOCATIONS OF ALL STUB-OUT CONVEYANCE LINES WITH RESPECT TO THE UTILITIES E.POWER, GAS, TELEPHONE, TELEVISION). ALL INDIVIDUAL STUB-OUTS SHALL BE PRIVATELY OWNED AND MAINTAINED BY THE LOT HOMEOWNER. 15.THE STORM DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO APPROVED PLANS ON FILE WITH THE CITY. ANY MATERIAL DEVIATION FROM THE APPROVED PLANS WILL REQUIRE WRITTEN APPROVAL FROM THE CITY. 16.ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR SIMILARLY STABILIZED TO THE SATISFACTION OF THE CITY. FOR SITES WHERE GRASS HAS BEEN PLANTED THROUGH HYDRO SEEDING, THE PERFORMANCE BOND WILL NOT BE RELEASED UNTIL THE GRASS HAS BEEN THOROUGHLY ESTABLISHED, UNLESS OTHERWISE APPROVED BY THE CITY. 17.ALL BUILDING DOWNSPOUTS ON COMMERCIAL SITES SHALL BE CONNECTED TO THE STORM DRAINAGE SYSTEM, UNLESS OTHERWISE APPROVED BY THE CITY. 18.ALL EROSION CONTROL AND STORMWATER FACILITIES SHALL BE REGULARLY INSPECTED AND MAINTAINED BY THE CONTRACTOR DURING THE CONSTRUCTION PHASE OF THE DEVELOPMENT PROJECT. 19.NO FINAL CUT OR FILL SLOPE SHALL EXCEED TWO (2) HORIZONTAL TO ONE (1) VERTICAL WITHOUT STABILIZATION BY ROCKERY OR BY A STRUCTURAL RETAINING WALL. 20.THE PROJECT ENGINEER SHALL VERIFY THE LOCATIONS, WIDTHS, THICKNESSES, AND ELEVATIONS OF ALL EXISTING PAVEMENTS AND STRUCTURES, INCLUDING UTILITIES AND OTHER FRONTAGE IMPROVEMENTS, THAT ARE TO INTERFACE WITH NEW WORK, AND PROVIDE ALL TRIMMING, CUTTING, SAW CUTTING, GRADING, LEVELING, SLOPING, COATING, AND OTHER WORK, INCLUDING MATERIALS NECESSARY TO CAUSE THE INTERFACE WITH EXISTING WORKS TO BE PROPER, WITHOUT CONFLICT, ACCEPTABLE TO THE PROJECT ENGINEER AND THE CITY’S CIVIL REVIEW ENGINEER, COMPLETE IN PLACE, AND READY TO USE. 21.COMPACTION OF ALL FILL AREAS SHALL BE PER CURRENT APWA SPECIFICATIONS. FILL SHALL BE PROVIDED IN 6" MAXIMUM LIFTS AND SHALL BE COMPACTED TO 95 PERCENT OF ITS MAXIMUM RELATIVE DENSITY. 1.THE CONTRACTOR SHALL OBTAIN ALL APPROVALS AND PERMITS REQUIRED BY THE CITY OF YELM (CITY) PRIOR TO THE START OF CONSTRUCTION. A GRADING PERMIT FOR STORM POND CONSTRUCTION MAY BE REQUIRED. 2.STORM DRAIN PIPE SHALL BE ON THE WSDOT QUALIFIED PRODUCTS LIST FOR THE SPECIFICATION LISTED BELOW: A.PLAIN CONCRETE STORM SEWER PIPE OR REINFORCED CONCRETE STORM SEWER PIPE PER WSDOT STANDARD SPECIFICATION 9-05.7. B.SOLID WALL PVC STORM SEWER PIPE PER WSDOT STANDARD SPECIFICATION 9- 05.12(1). C.DUCTILE IRON SEWER PIPE PER WSDOT STANDARD SPECIFICATION 9-05.13. D.HANCOR BLUE SEAL ™ AND ADVANCED DRAINAGE SYSTEMS (ADS/HANCOR) N-12 HDPE AND (ADS/HANCOR) SANITITE UP TO 36” IN DIAMETER PER WSDOT STANDARD SPECIFICATIONS 9-05.20 AND 9-05.24. E.CONTECH DUROMAXX STEEL RIB REINFORCED POLYETHYLENE PIPE, IN DIAMETERS FROM 24 INCH TO 60 INCH PER WSDOT STANDARD SPECIFICATION 9-05.22. 3.ALL STORM DRAINAGE SYSTEMS SHALL BE AIR TESTED AT 4 PSI EXCEPT CONCRETE PIPE, WHICH SHALL BE TESTED PER WSDOT/APWA STANDARD FOR CONCRETE STORM PIPE. ALL FLEXIBLE PIPE SHALL BE MANDREL TESTED PER WSDOT/APWA STANDARDS. TESTING SHALL BE DONE BY THE CONTRACTOR. 4.TESTING OF THE STORM SEWER SHALL INCLUDE VIDEOTAPING OF THE MAIN BY THE CONTRACTOR. IMMEDIATELY PRIOR TO VIDEOTAPING, ENOUGH WATER SHALL BE RUN DOWN THE LINE SO IT COMES OUT THE LOWER CATCH BASIN. A COPY OF THE VIDEO TAPE SHALL BE SUBMITTED TO THE CITY. ACCEPTANCE OF THE LINE WILL NOT BE MADE UNTIL AFTER THE TAPE HAS BEEN REVIEWED AND APPROVED BY THE CITY. TESTING SHALL TAKE PLACE AFTER ALL UNDERGROUND UTILITIES ARE INSTALLED AND COMPACTION OF THE ROADWAY SUBGRADE IS COMPLETE. 5.SPECIAL STRUCTURES, OIL/WATER SEPARATORS AND OUTLET CONTROLS SHALL BE INSTALLED PER PLANS AND MANUFACTURERS' RECOMMENDATIONS. WHERE OIL/WATER SEPARATORS ARE CONNECTED TO A SEWER SYSTEM, THEY SHALL BE INSTALLED WITH A P-TRAP OR CHECK VALVE TO PREVENT ODORS. 6.ALL DISTURBED AREAS SHALL BE STABILIZED IN ACCORDANCE WITH MINIMUM REQUIREMENT 2 OF THE LATEST EDITION OF THE DEPARTMENT OF ECOLOGY STORMWATER MANAGEMENT MANUAL FOR WESTERN WASHINGTON (SWMMWW). FOR SITES WHERE VEGETATION HAS BEEN PLANTED THROUGH HYDRO SEEDING, THE FINANCIAL GUARANTEE WILL NOT BE RELEASED UNTIL THE VEGETATION HAS BEEN THOROUGHLY ESTABLISHED. 7.WHERE CONNECTIONS REQUIRE "FIELD VERIFICATION", THE CONTRACTOR SHALL EXPOSE SUCH CONNECTION POINTS AND FITTINGS 48 HOURS PRIOR TO DISTRIBUTING SHUTDOWN NOTICES. 8.ANY CHANGES TO THE DESIGN SHALL FIRST BE REVIEWED AND APPROVED BY THE PROJECT ENGINEER AND THE CITY’S CIVIL REVIEW ENGINEER. 9.ALL STORM PIPE SHALL BE A MINIMUM OF 12-INCH DIAMETER FOR MAINS AND CROSSINGS. WHEN PRIVATE STORMWATER (I.E. ROOF, LOT OR FOOTING DRAINS) CANNOT BE INFILTRATED ON INDIVIDUAL LOTS, THE MINIMUM STANDARD PIPING CONNECTION TO THE PUBLIC SYSTEM SHALL BE 8-INCH PVC. THE 8-INCH MAIN USED FOR CONNECTION SHALL BEGIN AT THE RIGHT-OF-WAY, AND THE CONNECTION TO THE CATCH BASIN OR MANHOLE SHALL BE CORED AND GROUTED. 10.ALL STORM MAINS AND RETENTION/DETENTION AREAS SHALL BE STAKED FOR GRADE AND ALIGNMENT BY AN ENGINEERING OR SURVEY FIRM LICENSED TO PERFORM SUCH WORK. YELM STORMWATER NOTES CONT. 10/19/2021 340 345 350 355 340 345 350 355 0+00FG 351.77FG 351.370+50FG 350.97FG 350.191+00FG 349.36FG 348.621+50FG 348.20FG 347.932+00FG 347.78FG 347.722+50FG 347.61FG 347.493+00FG 347.62FG 347.843+50FG 348.05FG 347.474+00FG 347.09FG4+50FG 346.80FG 345.865+00FG 345.23FG 343.925+50FG 343.74FG 343.516+00FG 344.04FG 344.236+41.77FG 343.38PROPOSED FINISHED GRADE AT SECTION LINE EXISTING GRADE AT SECTION LINE PROPOSED FINISHED GRADE ELEVATION AT SECTION LINE EXISTING GRADE ELEVATION AT SECTION LINE BUILDING ONE FF: 349.10 BUILDING TWO FF: 347.56 BUILDING THREE FF: 347.56 BUILDING FOUR FF: 345.50 MAX 3H:1V SLOPE Profile View of WEST EAST SEC2 340 345 350 340 345 350 0+00FG 345.95FG 346.150+50FG 346.24FG 346.191+00FG 346.00FG 345.921+50FG 345.47FG 345.062+00FG 345.25FG 345.072+50FG 344.45FG 344.373+00FG 344.26FG 344.223+45.06FG 344.72BUILDING FOUR FF: 345.50 MAX 3H:1V SLOPE MAX 3H:1V SLOPE PROPOSED FINISHED GRADE ELEVATION AT SECTION LINE EXISTING GRADE ELEVATION AT SECTION LINE PROPOSED FINISHED GRADE AT SECTION LINE EXISTING GRADE AT SECTION LINE TAHOMA BOULEVARD SE1 2 3 4 TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 253.383.2572 FAX 28 SKML/EAML/EA 10/18/2021 CIVIL PERMIT SET 2210016.10 PO BOX 597 PUYALLUP, WA 98371 JERRY SCHUUR SCHUUR BROTHERS CONSTRUCTION TAHOMA BOULEVARD APARTMENTS A PORTION OF THE NW 1/4 OF THE SE 1/4 OF SEC. 24, TWN. 17 N., RGE. 01 E. W.M. CITY OF YELM, THURSTON COUNTY, WASHINGTON. TAHOMA BOULEVARD APARTMENTS DATE: September 29, 2021 FILENAME: Q:\2021\2210016\10_CIV\CAD\_Site Development\2210016-SH-GRAD-DTLS.dwg C3.2 11 SITE SECTIONS 1 SCALE: 1"=30'H 1"=3'V SITE SECTION 1 2 SCALE: 1"=30'H 1"=3'V SITE SECTION 2 1 C3.2 2 C3.2 KEYMAP SCALE: 1" = 50'N10/19/2021 337 340 345 350 337 340 345 350 0+00FG 351.72FG 351.590+50FG 351.54FG 351.061+00FG 350.55FG 350.151+50FG 350.07FG 349.902+00FG 349.35FG 348.842+50FG 348.47FG 348.203+00FG 347.99FG 347.863+50FG 347.77FG 347.604+00FG 347.40FG 347.384+50FG 347.40FG 347.445+00FG 347.35FG 346.765+50FG 345.94FG 345.346+00FG 344.62FG 344.276+50FG 344.10FG 344.357+00FG 344.677+13.92FG 344.90N: 594352.62 E: 1110857.01 IE: 345.12 12" (E) RIM: 348.19 CB# 1, TYPE 1 109 LF 12" CPEP @ 0.50% N: 594349.75 E: 1110965.61 IE: 344.58 12" (W) IE: 344.58 12" (E) IE: 344.91 8" (N) RIM: 348.19 CB# 2, TYPE 1 54 LF 12" CPEP @ 0.50% N: 594348.31 E: 1111019.91 IE: 344.31 12" (W) IE: 344.31 12" (N) RIM: 348.73 CB# 3, TYPE 1 137 LF 12" CPEP @ 0.50% N: 594485.75 E: 1111023.54 IE: 343.62 12" (N) IE: 343.62 12" (S) IE: 343.62 12" (W) RIM: 348.12 CB# 4, TYPE 1 137 LF 12" CPEP @ 0.50% N: 594623.19 E: 1111027.16 IE: 342.93 12" (S) IE: 342.93 12" (N) IE: 342.93 12" (W) RIM: 346.75 CB# 5, TYPE 1 114 LF 12" CPEP @ 0.50% CB# 6, TYPE 1 N: 594737.14 E: 1111030.17 RIM: 345.61 IE: 342.36 12" (S) IE: 342.36 12" (N) IE: 342.36 12" (W) 114 LF 12" CPEP @ 0 . 7 8 % CB# 7, TYPE 1 N: 594850.64 E: 1111033.17 RIM: 344.47 IE: 341.47 12" (S) IE: 341.47 12" (N) 34 LF 12" CPEP @ 3.10% 335 340 345 350 335 340 345 350 0+00FG 348.18FG 347.520+50FG 347.32FG 347.211+00FG 346.96FG 346.831+50FG 346.85FG 346.772+00FG 346.78FG 346.722+50FG 346.45FG 346.353+00FG 346.27FG 345.883+50FG 344.35FG 342.904+00FG 342.59FG 342.704+50FG 342.94FG 343.095+00FG 343.47FG 343.605+50FG 343.83FG 344.156+00FG 344.556+25FG 344.83N: 594516.10 E: 1110763.52 IE: 343.83 8" (E) IE: 343.50 12" (N) RIM: 347.89 CB# 14, TYPE 1 114 LF 12" DI CL52 @ 0.50% N: 594630.06 E: 1110766.56 IE: 342.93 12" (N) IE: 342.93 12" (S) IE: 342.93 12" (E) RIM: 346.75 CB# 13, TYPE 1 114 LF 12" CPEP @ 0.50% N: 594744.02 E: 1110769.58 IE: 342.36 12" (N) IE: 342.36 12" (S) IE: 342.36 12" (E) RIM: 345.61 CB# 12, TYPE 1 114 LF 12" CPEP @ 0.50% N: 594858.06 E: 1110772.56 IE: 341.79 12" (S) IE: 341.79 12" (NE) RIM: 344.47 CB# 11, TYPE 1 47 LF 12" CPEP @ 0.50% N: 594890.18 E: 1110806.41 IE: 341.56 12" (SW) IE: 341.56 12" (E) IE: 341.89 8" (SE) RIM: 344.99 CB# 10, TYPE 1 194 LF 12" CPEP @ 0.50% CB# 9, TYPE 1 N: 594885.10 E: 1110999.84 RIM: 344.80 IE: 340.59 12" (W) IE: 340.59 12" (E) IE: 340.92 8" (S) 34 LF 12" CPEP @ 0.50% 340 345 350 340 345 350 0+00FG 347.62FG 347.790+50FG 347.79FG 347.591+00FG 347.55FG 347.401+50FG 347.361+69.90FG 347.2072 LF 12" CPEP @ 0.50% CB# 5, TYPE 1 N: 594623.19 E: 1111027.16 RIM: 346.75 IE: 342.93 12" (S) IE: 342.93 12" (N) IE: 342.93 12" (W) CB# 16, TYPE 1 N: 594625.08 E: 1110955.52 RIM: 346.29 IE: 343.62 8" (S) IE: 343.29 12" (E) IE: 343.62 8" (N) 340 345 350 340 345 350 0+00FG FG 346.980+50FG 346.84FG 347.071+00FG 347.10FG 347.091+50FG 347.25FG 347.681+90.59FG 347.77CB# 13, TYPE 1 N: 594630.06 E: 1110766.56 RIM: 346.75 IE: 342.93 12" (N) IE: 342.93 12" (S) IE: 342.93 12" (E) 72 LF 12" CPEP @ 0.50% CB# 15, TYPE 1 N: 594628.17 E: 1110838.20 RIM: 346.29 IE: 343.29 12" (W) IE: 343.62 8" (S) IE: 343.62 8" (NE) 1 2 3 4 TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 253.383.2572 FAX 28 SKML/EAML/EA 10/18/2021 CIVIL PERMIT SET 2210016.10 PO BOX 597 PUYALLUP, WA 98371 JERRY SCHUUR SCHUUR BROTHERS CONSTRUCTION TAHOMA BOULEVARD APARTMENTS A PORTION OF THE NW 1/4 OF THE SE 1/4 OF SEC. 24, TWN. 17 N., RGE. 01 E. W.M. CITY OF YELM, THURSTON COUNTY, WASHINGTON. TAHOMA BOULEVARD APARTMENTS DATE: September 29, 2021 FILENAME: Q:\2021\2210016\10_CIV\CAD\_Site Development\2210016-SH-GRAD-DTLS.dwg C3.3 12 STORM PROFILES 1 SCALE: 1"=30'H 1"=3'V STORM RUN 1 2 SCALE: 1"=30'H 1"=3'V STORM RUN 2 3 SCALE: 1"=30'H 1"=3'V STORM RUN 3 4 SCALE: 1"=30'H 1"=3'V STORM RUN 4 EXISTING GRADE AT STORM CENTERLINE PROPOSED GRADE AT STORM CENTERLINE FINISHED GRADE ELEVATION AT STORM CENTERLINE EXISTING GRADE ELEVATION AT STORM CENTERLINE EXISTING GRADE AT STORM CENTERLINE PROPOSED GRADE AT STORM CENTERLINE FINISHED GRADE ELEVATION AT STORM CENTERLINE EXISTING GRADE ELEVATION AT STORM CENTERLINE EXISTING GRADE AT STORM CENTERLINE PROPOSED GRADE AT STORM CENTERLINE FINISHED GRADE ELEVATION AT STORM CENTERLINE EXISTING GRADE ELEVATION AT STORM CENTERLINE EXISTING GRADE AT STORM CENTERLINE PROPOSED GRADE AT STORM CENTERLINE FINISHED GRADE ELEVATION AT STORM CENTERLINE EXISTING GRADE ELEVATION AT STORM CENTERLINE 10/19/2021 12" PIPE NATIVE MATERIAL BACKFILL COMPACT TO 90% OF MAX DENSITY UNDER LANDSCAPED AREAS AND 95% OF MAX DENSITY UNDER PAVED SURFACES 12" PERF. PIPE GEOTEXTILE FABRIC WASHED DRAIN ROCK NATIVE MATERIAL. DO NOT COMPACT. 0.0% 127'IE: SEE PLAN TYPE 2 CATCH BASIN RIM: PER PLAN 6" PVC PIPE HS-20 RATED CAP. RIM: SEE PLAN 6" PERFORATED PVC. PERFORATIONS SHALL BE 0.25" DIAMETER SPACED 3" ON CENTER. OBSERVATION WELL WITH REMOVABLE CAP LOCATION VARIES. SEE PLAN 12" X12" METAL FOOT PLATE FINISHED GRADE (PER PLAN) STORM CLEANOUT RIM PER PLAN GRADATION NOTES: 1.WASHED DRAIN ROCK SHALL CONFORM TO WSDOT SPECIFICATION 9-03.12 (5) GRAVEL BACKFILL FOR DRY WELLS 4' WASHED DRAIN ROCK, SEE GRADATION NOTES 12" PERF CPEP @ 0.00% 10' O.C. IE = 337.30 NATIVE MATERIAL, DO NOT COMPACT SEE DETAIL 20' BOTTOM IE: 336.30 TOP IE: 340.30 5' NATIVE MATERIAL BACKFILL, COMPACT TO 90% OF MAX DENSITY WRAP TOP AND SIDES OF GALLERY WITH GEOTEXTILE FABRIC MIRAFI 140N OR APPROVED EQUIVALENT ASPHALT PAVEMENT SECTION / LANDSCAPE (VARIES) 10'5' 1 2 3 4 TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 253.383.2572 FAX 28 SKML/EAML/EA 10/18/2021 CIVIL PERMIT SET 2210016.10 PO BOX 597 PUYALLUP, WA 98371 JERRY SCHUUR SCHUUR BROTHERS CONSTRUCTION TAHOMA BOULEVARD APARTMENTS A PORTION OF THE NW 1/4 OF THE SE 1/4 OF SEC. 24, TWN. 17 N., RGE. 01 E. W.M. CITY OF YELM, THURSTON COUNTY, WASHINGTON. TAHOMA BOULEVARD APARTMENTS DATE: September 29, 2021 FILENAME: Q:\2021\2210016\10_CIV\CAD\_Site Development\2210016-SH-GRAD-DTLS.dwg C3.4 13 GRADING AND DRAINAGE NOTES AND DETAILS 1 NOT TO SCALE INFILTRATION SECTION 2 NOT TO SCALE STORMFILTER VAULT 1 C3.5 5 C3.5 10/19/2021 1 2 3 4 TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 253.383.2572 FAX 28 SKML/EAML/EA 10/18/2021 CIVIL PERMIT SET 2210016.10 PO BOX 597 PUYALLUP, WA 98371 JERRY SCHUUR SCHUUR BROTHERS CONSTRUCTION TAHOMA BOULEVARD APARTMENTS A PORTION OF THE NW 1/4 OF THE SE 1/4 OF SEC. 24, TWN. 17 N., RGE. 01 E. W.M. CITY OF YELM, THURSTON COUNTY, WASHINGTON. TAHOMA BOULEVARD APARTMENTS DATE: September 29, 2021 FILENAME: Q:\2021\2210016\10_CIV\CAD\_Site Development\2210016-SH-GRAD-DTLS.dwg C3.5 14 GRADING AND DRAINAGE NOTES AND DETAILS CAP AT END 7-3/4" 15" 8" 7" PACKING 45° (1/8) BEND 2-7/8" 2'-0" 10" 8-3/4" 1-1/4" 1/2"2" 9" 1" 1" FIBRE JOINT4"1. PIPE MATERIAL AS SPECIFIED BY THE ENGINEER. 2. PIPE DIAMETER AS SHOWN 5/8" 1'-0" NOTES: 1/2" PER PLAN. RAISE - 1/2" WIDE BORDER PROVIDE COUPLINGS & REDUCERS AS NECESSARY 3000 PSI CLASS C CONCRETE (TYP.) (LANDSCAPE AREAS ONLY) ROOF DOWNSPOUT SEE ARCHITECTURAL DETAILS. STUD WALL SEE STRUCTURAL DETAILS. 4" 6" PVC PROVIDE FITTINGS 0.5% AS REQUIRED. SDR 35 TYP. 6" PVC CAP CUT HOLE TO ALLOW DOWNSPOUT TO PENETRATE WITH 1/8" CLEARANCE. FOOTING SUBDRAIN BUILDING FOUNDATION SEE STRUCTURAL DETAILS MIN. FINISH GRADE 2" MIN. 12" MIN. NOTE BACKFILL MATERIAL SHALL NOT HAVE PARTICLE SIZE GREATER THAN 1" WITHIN 6" OF THE PIPE OR THE CONTRACTOR HAS THE OPTION TO USE GRAVEL BACKFILL PIPE ZONE BEDDING CONFORMING TO W.S.D.O.T. 9-03.12 (3). 6" PVC 3 C3.3 FRAME AND VANED GRATE RECTANGULAR ADJUSTMENT SECTION 3"4" MI N. ( T Y P.) 34" 5" #3 BAR EACH WAY SEE NOTE 1 NOTES: 1.AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN IN THE PRECAST BASE SECTION, FIBERS (PLACED ACCORDING TO THE STANDARD SPECIFICATIONS), OR WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT SHALL BE USED WITH THE MINIMUM REQUIRED REBAR SHOWN IN THE ALTERNATIVE PRECAST BASE SECTION. WIRE MESH SHALL NOT BE PLACED IN THE KNOCKOUTS. 2.THE KNOCKOUT DIAMETER SHALL NOT BE GREATER THAN 20". KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 3.THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE LOWEST PIPE INVERT SHALL BE 5'. 4.THE FRAME AND GRATE MAY BE INSTALLED WITH THE FLANGE UP OR DOWN. THE FRAME MAY BE CAST INTO THE ADJUSTMENT SECTION. 5.THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF 1:24 OR STEEPER. 6.THE OPENING SHALL BE MEASURED AT THE TOP OF THE PRECAST BASE SECTION. 7.ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE BASIN HAS BEEN PLACED. #3 BAR EACH CORNER #3 BAR EACH CORNER 18" MIN. 26"(SEE N O T E 6) 22 " (S E E N O T E 6 )4"44"21" MIN.24" 30 " 20 " 5" 6" OR 12" ONE #3 BAR HOOP FOR 6" HEIGHT TWO #3 BAR HOOPS FOR 12" HEIGHT ALTERNATIVE PRECAST BASE SECTION #3 BAR EACH SIDE SECTION B-B #3 BAR HOOP *CORRUGATED POLYETHYLENE STORM SEWER PIPE PIPE ALLOWANCES PIPE MATERIAL MAXIMUM INSIDE DIAMETER REINFORCED OR PLAIN CONCRETE 12" ALL METAL PIPE 15" CPSSP* (STD. SPEC. 9-05.20)12" SOLID WALL PVC (STD. SPEC. 9-05.12(1))15" PROFILE WALL PVC (STD. SPEC. 9-05.12(2))15" NOTE: 1.NO STEPS ARE REQUIRED WHEN HEIGHT IS 4' OR LESS. 2.THE BOTTOM OF THE PRECAST CATCH BASIN MAY BE SLOPED TO FACILITATE CLEANING. 3.THE RECTANGULAR FRAME AND GRATE MAY BE INSTALLED WITH THE FLANGE UP OR DOWN. THE FRAME MAY BE CAST INTO THE ADJUSTMENT SECTION. 4.KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. SEPARATE BASE PRECAST INTEGRAL BASE PRECAST WITH RISER PIPE ALLOWANCES CATCH BASIN DIAMETER PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER CONCRETE ALL METAL CPSSP SOLID WALL PVC PROFILE WALL PVC 48"24"30"24"27"30" 54"30"36"30"27"36" 60"36"42"36"36"42" 72"42"54"42"36"48" 84"54"60"54"36"48" 96"60"72"60"36"48" CORRUGATED POLYETHYLENE STORM SEWER PIPE (STD. SPEC. 9-05.20) (STD. SPEC. 9-05.12(1)) (STD. SPEC. 9-05.12(2)) 1 2 3 1 2 3 CATCH BASIN DIMENSIONS CATCH BASIN DIAMETER WALL THICKNESS BASE THICKNESS MAXIMUM KNOCKOUT SIZE MINIMUM DISTANCE BETWEEN KNOCKOUTS 48"4"6"36"8" 54"4.5"8"42"8" 60"5"8"48"8" 72"6"8"60"12" 84"8"12"72"12" 96"8"12"84"12" 1 NOT TO SCALE STORM CLEANOUT 2 NOT TO SCALE DOWNSPOUT CONNECTION 3 NOT TO SCALE STORM TRENCH SECTION 4 NOT TO SCALE TYPE 1 CATCH BASIN 5 NOT TO SCALE TYPE 2 CATCH BASIN 6"0D6" MIN FLEXIBLERIGID (DI, CONC) TRENCH WIDTH PER WSDOT 2-09.40.5 x OD(CPEP, CMP, PVC) BACKFILL UTILITY TRENCHES WITHIN PAVED AREAS WITH BANKRUN GRAVEL PER WSDOT 9-03.19. COMPACT TO A MINIMUM OF 95% UNLESS NOTED OTHERWISE IN PROJECT SPECIFICATIONS. TRENCHES MAY BE BACKFILLED WITH NATIVE MATERIAL AND COMPACTED TO 90% IN UNPAVED AREAS. PIPE BEDDING PER W.S.D.O.T. 9-03.12(3), 95% COMPACTION PIPE AS SPECIFIED ON PLAN OR SPECS SUBGRADE ELEVATION 10/19/2021 347351352349 FIRE HYDRANT N 594606.29 E 1110999.76 FIRE HYDRANT N 594383.37 E 1110782.86 15' WATER EASEMENT, TYP. 10' 15' FIRE HYDRANT N 594657.79 E 1110788.57 3503473 4 8 3 4 9351 3 4 5 3453443463463453433443 4 6 SSCO #3 N 594511.38 E 1110866.89 RIM: 347.65 IE: 343.25 6" (S) 29 LF 6" PVC SDR 35 @ 2.00%SSCO #2 N 594394.66 E 1110870.70 RIM: 349.06 IE: 344.69 6" (NE) IE: 344.69 6" (W) 5 LF 6" PVC SDR 35 @ 2.00% 17 LF 6" PVC SDR 35 @ 2.00% 4 LF 6" PVC SDR 35 @ 2.00% 9 LF 6" PVC SDR 35 @ 2.00% 17 LF 6" PVC SDR 35 @ 2.00% 4 LF 6" PVC SDR 35 @ 2.00% PUMP CONTROL PANEL (TYP) FIRE HYDRANT N 594860.72 E 1110794.01 S1° 30' 43"W 641.71'S88° 14' 50"E344.86'S1° 30' 17"W 596.42' Δ=16°00'26" R=547.00' L=152.82'N88° 13' 17"W199.33'3,000 GAL HOLDING TANK (TYP) 1,250 GAL PUMP TANK (TYP) 348348349349349 3493 4 9 3 4 8 3 4 7 3 4 6 3 4 5 34534534434334234134534734734734734734835 1 3453 4 4 347346346347347347SSCO #6 N 594682.83 E 1110823.09 RIM: 347.54 IE: 342.56 6" (W) SSCO #8 N 594687.27 E 1110806.16 RIM: 347.17 IE: 342.14 6" (S) SSCO #7 N 594683.27 E 1110806.05 RIM: 347.17 IE: 342.22 6" (E) IE: 342.22 6" (N) SSCO #9 N 594779.34 E 1110825.63 RIM: 346.45 IE: 341.50 6" (W) SSCO #11 N 594783.79 E 1110808.69 RIM: 346.51 IE: 341.08 6" (S) SSCO #10 N 594779.79 E 1110808.58 RIM: 346.60 IE: 341.16 6" (E) IE: 341.16 6" (N) SSCO #1 N 594402.51 E 1110883.83 RIM: 349.09 IE: 345.00 6" (SW) SSCO #4 N 594482.20 E 1110866.15 RIM: 348.19 IE: 342.67 6" (N) IE: 342.67 6" (W) SSCO #5 N 594482.48 E 1110856.74 RIM: 348.21 IE: 342.48 6" (E) 28 LF 2" PVC SDR 21 CL200 54 LF 2" PVC SDR 21 CL200 33 LF 2" PVC SDR 21 CL200 540 LF 2" PVC SDR 21 CL200 1 - 2" 90° BEND (MJ) CONCRETE THRUST BLOCKING N 594899.34 E 1110841.53 CONNECT TO EXISTING 4" FORCE MAIN 1 - 4" 22.5° BEND (FL) 1 - 4"x2" REDUCER (FL) 1 - 2" GATE VAVLE (FLxMJ) CONCRETE THRUST BLOCKING N 594927.56 E 1110842.27 1 - 2" 45° BEND (MJ) CONCRETE THRUST BLOCKING N 594900.52 E 1110787.33 1 - 2" 45° BEND (MJ) CONCRETE THRUST BLOCKING N 594877.49 E 1110763.06 2" PRESSURE SEWER SERVICE LINE TO STEP TANKS N 594833.75 E 1110761.95 2" PRESSURE SEWER SERVICE LINE TO STEP TANKS N 594737.34 E 1110759.41 2" PRESSURE SEWER SERVICE LINE TO STEP TANKS N 594485.24 E 1110752.84 2" PRESSURE SEWER SERVICE LINE TO STEP TANKS N 594411.91 E 1110750.93 END OF LINE CLEANOUT N 594337.75 E 1110749.00 15 LF 6" PVC SDR 35 @ 2.00% SEWER SERVICE "CARSON" BOX SEWER SERVICE "CARSON" BOX SEWER SERVICE "CARSON" BOX 1 2 3 4 TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 253.383.2572 FAX 28 SKML/EAML/EA 10/18/2021 CIVIL PERMIT SET 2210016.10 PO BOX 597 PUYALLUP, WA 98371 JERRY SCHUUR SCHUUR BROTHERS CONSTRUCTION TAHOMA BOULEVARD APARTMENTS A PORTION OF THE NW 1/4 OF THE SE 1/4 OF SEC. 24, TWN. 17 N., RGE. 01 E. W.M. CITY OF YELM, THURSTON COUNTY, WASHINGTON. TAHOMA BOULEVARD APARTMENTS DATE: October 18, 2021 FILENAME: Q:\2021\2210016\10_CIV\CAD\_Site Development\2210016-SH-OVERALL-UTIL.dwg C4.0 15 OVERALL SEWER AND WATER PLANNGRAPHIC SCALE 0 30 60 1" = 30 FEET 15 TAHOMA BLVD SE ROAD 'A' (BY OTHERS) PROPOSED 12"-18" STORM MAIN, TYP. (SIZE VARIES) BLDG 1 BLDG 2 BLDG 3 BLDG 4 8' FF: 349.10 FF: 347.75 FF: 347.56 FF: 346.50 BUILDING 2, 3, 4 (24-UNIT APARTMENT BUILDING) ASSUMED RESIDENTS PER HOUSEHOLD = 2.5 GALLONS PER RESIDENT PER DAY (FROM TABLE 2 OF SECTION 5.10.010 YELM ESSD, 2019) = 65 GPD/PERSON AVERAGE DAILY FLOW BUILDING A = 65*2.5*24 = 3,900 GPD DETENTION VOLUME = 1.5*3,900 = 5,850 GALLONS TOTAL TANK VOLUME (PER SECTION C1-10.1.6 OF DOE CRITERIA FOR SEWAGE WORKS DESIGN) TOTAL TANK VOLUME = 1.65V; VT=1.65*5,850-GAL = 9,653-GAL TANK DISTRIBUTION BUILDING 2, 3, 4 9,653*(2/3) = 6,467 GAL TANK 1 & 2 9,653*(1/3) = 3,186 GAL TANK 3 TANK 1 - 3,000-GAL; TANK 2 - 3,000-GAL; TANK 3 - 3,000; TANK 4 - 1,250-GAL PUMP TANK BUILDING 1 (8-UNIT APARTMENT BUILDING) AVERAGE DAILY FLOW BUILDING B = 65*2.5*8 = 1,300 GPD DETENTION VOLUME = 1.5*1,300 = 1,950 GALLONS TOTAL TANK VOLUME (PER SECTION C1-10.1.6 OF DOE CRITERIA FOR SEWAGE WORKS DESIGN) TOTAL TANK VOLUME = 1.65V; VT=1.65*1,950-GAL = 3,218-GAL TANK DISTRIBUTION BUILDING 1 3,218*(2/3) = 2,157 GAL 3,218*(1/3) = 1,062 GAL TANK 1 - 2,000-GAL; TANK 2 - 1,250 PUMP TANK TANK SIZING CALCULATIONS AND ASSUMPTIONS BERRY VALLEY RD10' SEWER LEGEND RIGHT-OF-WAY / PROPERTY LINE CENTERLINE EASEMENT BUILDING OUTLINE SANITARY SIDE SEWER SANITARY SEWER FORCE MAIN SANITARY SEWER CLEANOUT STEP TANK PUMP CONTROL PANEL PROPOSED MINOR CONTOUR PROPOSED MAJOR CONTOUR 123 123 WATER LEGEND FIRE HYDRANT FIRE DEPARTMENT CONNECTION (FDC) METER AS NOTED POST INDICATOR VALVE (PIV) GATE VALVE THRUST BLOCKING FITTINGS AS NOTED WATER PIPING WATER SERVICE PIPING FIRE SERVICE PIPING CONTRACTOR SHALL INSTALL BLIND FLANGE AT PROPERTY LINE AND MARK LOCATION IF ROAD 'A' IS NOT CONSTRUCTED. NO WORK BEYOND PROPERTY LINE IS ALLOWED PRIOR TO DEDICATION OF RIGHT-OF-WAY. STEP MAIN SIZING NUMBER OF PUMPS CONNECTED:4 MAX. PUMP CORES RUNNING SIMULTANEOUSLY (TABLE IV): 3 PROPOSED STEP MAIN SIZE: 2" FLOW VELOCITY (TABLE VIII): 2.92 FT/SEC FRICTION HEAD LOSS (TABLE VIII): 1.54 FT/100 LF 2,000 GAL HOLDING TANK 1,250 GAL PUMP TANK DEPTH TO INVERT: 4.10' DEPTH TO INVERT: 4.50' DEPTH TO INVERT: 5.00'DEPTH TO INVERT: 5.00' 1 C4.4 2 C4.4 PROPOSED 8" PVC C900 WATER MAIN (TYP) WATER MAIN POINT OF CONNECTION STEP TANK NOTE MAXIMUM COVER OVER STEP TANK(S) MEASURED FROM FINISHED GRADE (FG) IS 5 FEET TO TOP SLAB OR 6.25 FEET TO INVERT PER DETAILS ON SHEET C4.4 FUTURE 8" WATER MAIN PER WYNDSTONE PROJECT 5-20 C4.4 5-7 C4.5 5-7 C4.5 5-7 C4.5 5-7 C4.5 4-4.4 C4.7 4-7 C4.8 4-3 C4.7 4-11 C4.8 4-13 C4.8 4-14 C4.8 1 C4.4 2 C4.4 5-14 C4.4 5-17 C4.6 5-18 C4.6 5-6 C4.5 10/19/2021 347351352349 10'3503473 4 8 3 4 9 351 3 4 5 3453443463463453433443 4 6 S1° 30' 17"W 596.42'34834934934934734734734835 1 3453 4 4 3463473473+006+79 1+00 2+00 3+00 4+00 5+00 6+00 84 LF 8" PVC C900 29 LF 8" PVC C900 13 LF 8" PVC C900 224 LF 8" PVC C900 33 LF 6" DI CL52 60 LF 6" CI CL52 5 LF 6" DI CL52 60 LF 6" CI CL5238 LF 8" PVC C900 14 LF 8" PVC C900 178 LF 8" PVC C900 12 LF 6" DI CL52 12 LF 6" DI CL52 26 LF 6" DI CL52 11 LF 6" DI CL52 CONTINUATION PER MECHANICAL 10 LF 6" DI CL52 21 LF 6" DI CL52 25 LF 6" DI CL52 16 LF 6" DI CL52 11 LF 8" PVC C900 347346 264 LF 8" PVC C900337 340 345 350 355 337 340 345 350 355 1+00FG 1+50FG 349.952+00FG 348.932+50FG 348.433+00FG 347.933+50FG 347.434+00FG 346.934+50FG 346.435+00FG 345.935+50FG 345.436+00FG 344.936+50FG 344.51FGFG 349.21FG 348.68FG 348.18FG 347.68FG 347.18FG 346.68FG 346.18FG 345.68FG 345.18FG 344.68EXISTING GRADE ELEVATION AT DRIVE AISLE CENTERLINE PROPOSED GRADE ELEVATION AT DRIVE AISLE CENTERLINE EXISTING GRADE AT DRIVE AISLE CENTERLINE FINISHED GRADE AT DRIVE AISLE CENTERLINE 13 LF 8" PVC C900 224 LF 8"PVC C900 29 LF 8" PVC C900 36 LF 8" PVC C900 14 LF 8" PVC C900 178 LF 8"PVC C900 540 LF 2" PVC SDR 21 CL 2 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 CONNECT TO OFFSITE MAIN 1 - 8" TAPPING SLEEVE (FL) 1 - 8" TAPPING VALVE ( FLxMJ) N 594357.16 E 1110685.73 1 - 8" 90° BEND (MJ) CONC. THRUST BLOCKING N 594354.97 E 1110769.42 1 - 8"x6" TEE (MJxFL) 1 - 6" GATE VALVE (FL) 13 LF 6" DI CL52 1 - HYDRANT ASSEMBLY CONC. THRUST BLOCKING N 594383.70 E 1110770.22 1 - 8"x6" TEE (MJxFL) 1 - 6" GATE VALVE (FL) 1 - POST INDICATOR VALVE (FL) 1 - 6" DDCVA CONC. THRUST BLOCKING N 594395.99 E 1110770.49 1 - 6" 90° BEND (MJ) CONC. THRUST BLOCKING N 594389.32 E 1110809.11 1 - 6" 90° BEND (MJ) CONC. THRUST BLOCKING N 594393.95 E 1110821.95 CENTER POST INDICATOR VALVE N 594395.12 E 1110803.71 CENTER FIRE HYDRANT ASSEMBLY N 594383.37 E 1110782.86 CENTER FIRE DEPARTMENT CONNECTION N 594390.14 E 1110777.94 1 - 6" 90° BEND (MJ) CONC. THRUST BLOCKING N 594455.21 E 1110821.99 2" DOMESTIC SERVICE CONNECTION WITH RPBA N 594462.03 E 1110772.22 1 - 8" TEE (MJ) 3 - 8" GATE VALVE (MJ) CONC. THRUST BLOCKING N 594619.76 E 1110776.34 1 - 8"x6" TEE (MJxFL) 1 - 6" GATE VALVE (FL) 13 LF 6" DI CL52 1 - HYDRANT ASSEMBLY CONC. THRUST BLOCKING N 594657.88 E 1110777.39 14 15 16 17 18 19 20 21 22 23 24 25 26 27 E 1110777.39 1 - 8"x6" TEE (MJxFL) 1 - 6" GATE VALVE (FL) 1 - POST INDICATOR VALVE (FL) 1 - 6" DDCVA CONC. THRUST BLOCKING N 594671.85 E 1110777.75 1 - 6" 90° BEND CONC. THRUST BLOCKING N 594670.77 E 1110828.97 CENTER FIRE DEPARTMENT CONNECTION N 594657.32 E 1110795.78 CENTER FIRE HYDRANT ASSEMBLY N 594657.68 E 1110788.57 CENTER POST INDICATOR VALVE N 594671.52 E 1110790.11 1 - 8"x6" TEE (MJxFL) 1 - 6" GATE VALVE (FL) 1 - POST INDICATOR VALVE (FL) 1 - 6" DDCVA CONC. THRUST BLOCKING N 594850.07 E 1110782.35 1 - 8"x6" TEE (MJxFL) 1 - 6" GATE VALVE (FL) 13 LF 6" DI CL52 1 - HYDRANT ASSEMBLY CONC. THRUST BLOCKING N 594861.02 E 1110782.65 1 - 8" 90° BEND (MJ) CONC. THRUST BLOCKING N 594882.82 E 1110783.27 CENTER POST INDICATOR VALVE N 594849.41 E 1110807.82 1.5" IRRIGATION SERIVCE WITH DCVA N 594844.26 E 1110782.20 CENTER FIRE DEPARTMENT CONNECTION N 594868.08 E 1110806.59 CENTER FIRE HYDRANT ASSEMBLY N 594860.72 E 1110793.92 1 - 6" 90° BEND (MJ) CONC. THRUST BLOCKING N 594867.93 E 1110813.64 1 - 6" 90° BEND (MJ) CONC. THRUST BLOCKING N 594847.98 E 1110841.47 FIRE PROTECTION NOTES FIRE SPRINKLER NOTE THE FIRE SPRINKLER UNDERGROUND PIPING SHOWN ON THESE PLANS SHALL BE CONSIDERED FOR LOCATION PURPOSES ONLY. APPROVAL OF THE CIVIL PLANS DOES NOT CONSTITUTE OR IMPLY APPROVAL FOR INSTALLATION OF THE FIRE SPRINKLER UNDERGROUND PIPING. A SEPARATE PERMIT IS REQUIRED FOR THE INSTALLATION OF THE FIRE SPRINKLER UNDERGROUND PIPING. PLANS AND SPECIFICATIONS FOR THE UNDERGROUND LEAD-IN PIPING SHALL BE SUBMITTED TO THE CITY OF YELM BUILDING DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. ALL WORK ON THE UNDERGROUND PORTIONS OF FIRE PROTECTION SPRINKLER SYSTEMS AND/OR FIRE MAIN FOR HYDRANT PLACEMENT MUST BE INSTALLED AND CERTIFIED BY A LICENSED CONTRACTOR WHO HAS ACHIEVED A STATE LEVEL "U" CERTIFICATION. SUBCONTRACTING OF SUCH WORK TO PERSONS OR FIRMS NOT CURRENTLY LICENSED AS A FIRE PROTECTION SPRINKLER SYSTEM CONTRACTOR IS PROHIBITED UNDER WAC 212-80. FIRE PROTECTION NOTES 1.FIRE LINES SHALL BE RESTRAINED JOINTS AND PROVIDE THRUST BLOCKS AT ALL FITTINGS. 2.THE FIRE PROTECTION SYSTEM INCLUDING MATERIALS, SIZING, AND CONFIGURATION IS SUBJECT TO A CONTRACTOR PROVIDED DESIGN BY A FIRE PROTECTION ENGINEER, AND AS SUCH, THE FINAL DESIGN OF THE FIRE PROTECTION SYSTEM MAY DEVIATE FROM THE SYSTEM SHOWN. THE FIRE PROTECTION SYSTEM AS SHOWN FROM THE MAIN LINE TO THE CONNECTION AT THE BUILDING SPRINKLER IS INTENDED FOR LOCATION OF THE FIRE HYDRANTS AND FIRE DEPARTMENT CONNECTION ONLY. CONTRACTOR'S BID SHALL REFLECT THE CONDITIONS OF THE FIRE PROTECTION ENGINEER'S DESIGN. 3.CONTRACTOR SHALL COMPLY WITH ALL NATIONAL FIRE PROTECTION ASSOCIATION REQUIREMENTS AS SET FORTH BY "NFPA 13", ITS AMENDMENTS, AND LOCAL REQUIREMENTS, INCLUDING BUT NOT LIMITED TO ACQUISITION OF ALL PERMITS. 4.ALL VALVES ON FIRE LINE SHALL BE MONITORED BY THE FIRE CONTROL PANEL. 1 2 3 4 TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 253.383.2572 FAX 28 SKML/EAML/EA 10/18/2021 CIVIL PERMIT SET 2210016.10 PO BOX 597 PUYALLUP, WA 98371 JERRY SCHUUR SCHUUR BROTHERS CONSTRUCTION TAHOMA BOULEVARD APARTMENTS A PORTION OF THE NW 1/4 OF THE SE 1/4 OF SEC. 24, TWN. 17 N., RGE. 01 E. W.M. CITY OF YELM, THURSTON COUNTY, WASHINGTON. TAHOMA BOULEVARD APARTMENTS DATE: October 4, 2021 FILENAME: Q:\2021\2210016\10_CIV\CAD\_Site Development\2210016-SH-UTIL.dwg C4.1 16 WATER PLAN AND PROFILENGRAPHIC SCALE 0 30 60 1" = 30 FEET 15 TAHOMA BLVD SEROAD 'A' (BY OTHERS) WATER CONSTRUCTION UTILITY CROSSING TABLE TOP UTILITY BOTTOM BOTTOM UTILITY CROWN SEPARATION STA WATER: 345.19 SEWER: 343.69 1.50-FT 1+97.89 WATER: 343.47 SEWER: 341.97 0.50 - FT 2+70.14 WATER: 342.24 SEWER: 340.74 1.50-FT 3+76.46 STORM: 342.93 WATER: 342.43 0.50-FT 4+17.85 WATER: 341.30 SEWER: 339.80 1.50-FT 5+22.71 TOP UTILITY BOTTOM BOTTOM UTILITY CROWN SEPARATION STA WATER: 341.28 SEWER: 339.78 1.5-FT 5+24.21 STORM: 342.35 WATER: 341.91 0.40-FT 5+31.92 WATER: 340.62 SEWER: 338.91 1.71-FT 6+19.47 STORM: 341.63 WATER: 341.13 0.50-FT 6+55.92 A B C D E F G H I A B C D E F I WEST DRIVE AISLE - SOUTH TO NORTH V: 1" = 3' | H: 1" = 30' KEYNOTES SEWER FORCE MAIN POINT OF CONNECTION G H 1 2 3 4 5 67 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 CONTINUATION PER SHEET C4.3 CONTINUATION PER SHEET C4.2 CONTINUATION PER MECHANICAL CONTINUATION PER MECHANICAL 8 LF 6" DI CL52 22 LF 8" PVC C900 2 3 4 12 13 16 20 22 26 PROPOSED 12" STORM SEE SHEET C3.3 2" DOMESTIC SERVICE CONNECTION W/ RPBA 11 LF 8" PVC C900 22 LF 8" PVC C900 1" PRESSURE SEWER CONNECTION TO STEP TANKS 1" PRESSURE SEWER CONNECTION TO STEP TANKS 1" PRESSURE SEWER CONNECTION TO STEP TANKS 1" PRESSURE SEWER CONNECTION TO STEP TANKS END OF LINE CLEAN OUT I.E: 345.56 (2" N) 1 - 2" 45° BEND (MJ) CONC. THRUST BLOCKING 1.5' MIN SEPARATION (TYP) FUTURE 8" WATER MAIN PER WYNDSTONE PROJECT (PROVIDE CONNECTION ONCE OFFSITE MAIN IS INSTALLED) 1.5" IRRIGATION SERVICE CONNECTION W/ DCVA 4-4.4 C4.7 4-4.4 C4.7 4-7 C4.8 4-7 C4.8 4-4.4 C4.7 4-4 C4.9 4-3 C4.7 4-7 C4.8 4-3 C4.7 4-17 C4.9 4-4 C4.9 4-4 C4.9 4-4 C4.9 4-3 C4.7 5-1 C4.6 5-1 C4.6 5-1 C4.6 5-1 C4.6 4-3 C4.7 4-17 C4.9 4-16 C4.9 5-20 C4.4 CONTRACTOR SHALL INSTALL BLIND FLANGE AT PROPERTY LINE AND MARK LOCATION IF ROAD 'A' IS NOT CONSTRUCTED. NO WORK BEYOND PROPERTY LINE IS ALLOWED PRIOR TO DEDICATION OF RIGHT-OF-WAY. 10/19/2021 15' WATER EASEMENT, TYP. 15' S1° 30' 43"W 3 4 7 3 4 6 3 4 5 34534534434334234134734610+00 11+00 12+00 12+80 5+0023+0013 LF 8"PVC C900337 340 345 350 337 340 345 350 10+00FG 346.94FG 346.6910+50FG 346.44FG 346.1911+00FG 345.94FG 345.6911+50FG 345.44FG 345.1912+00FG 344.94FG 344.6912+50FG 344.53FG 345.0312+80.31FG 345.14264 LF 8" PVC C900 EXISTING GRADE ELEVATION AT DRIVE AISLE CENTERLINE PROPOSED GRADE ELEVATION AT DRIVE AISLE CENTERLINE 337 340 345 350 337 340 345 350 2+00FG FG2+50FG 344.14FG 344.943+00FG 344.98FG 345.163+50FG 345.34FG 345.514+00FG 345.68FG 345.464+50FG 345.22FG 344.985+00FG 344.86FG 345.115+50FG 5+71.33FG33 LF SDR 21 CL200 F.M. 46 LF SDR 21 CL200 F.M. EXISTING GRADE ELEVATION AT DRIVE AISLE CENTERLINE PROPOSED GRADE ELEVATION AT DRIVE AISLE CENTERLINE 1 - 2" 45° BEND (MJ) CONC. THRUST BLOCKING 1 - 2" 90° BEND (MJ) CONC. THRUST BLOCKING 91 LF 8" PVC C900 144 LF 8" PVC C900 345 344 346 346 345 343 344 N88° 13' 17"W 199.33' 345 345 344 343 342 34 1 345 345344 12+8026 27 28 29 30 31 1 - 8" 90° BEND (MJ) CONC. THRUST BLOCKING N 594882.82 E 1110783.27 1 - 8" TEE (MJ) 3 - 8" GATE VALVE (FL) CONC. THRUST BLOCKING N 594880.42 E 1110874.11 1 - 8" 22.5° BEND (MJ) CONC. THRUST BLOCKING N 594911.01 E 1110874.92 CONNECT TO EXISTING 8" WATER MAIN N 594934.93 E 1110863.12 2" DOMESTIC SERVICE CONNECTION WITH RPBA N 594879.94 E 1110892.30 1 - 6" 90° BEND (MJ) CONC. THRUST BLOCKING N 594847.98 E 1110841.47 32 33 1 - 8" 90° BEND (MJ) CONC. THRUST BLOCKING N 594876.63 E 1111018.90 1 - 8" 90° BEND (MJ) CONC. THRUST BLOCKING N 594613.59 E 1111012.02 FIRE PROTECTION NOTES FIRE SPRINKLER NOTE THE FIRE SPRINKLER UNDERGROUND PIPING SHOWN ON THESE PLANS SHALL BE CONSIDERED FOR LOCATION PURPOSES ONLY. APPROVAL OF THE CIVIL PLANS DOES NOT CONSTITUTE OR IMPLY APPROVAL FOR INSTALLATION OF THE FIRE SPRINKLER UNDERGROUND PIPING. A SEPARATE PERMIT IS REQUIRED FOR THE INSTALLATION OF THE FIRE SPRINKLER UNDERGROUND PIPING. PLANS AND SPECIFICATIONS FOR THE UNDERGROUND LEAD-IN PIPING SHALL BE SUBMITTED TO THE CITY OF YELM BUILDING DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. ALL WORK ON THE UNDERGROUND PORTIONS OF FIRE PROTECTION SPRINKLER SYSTEMS AND/OR FIRE MAIN FOR HYDRANT PLACEMENT MUST BE INSTALLED AND CERTIFIED BY A LICENSED CONTRACTOR WHO HAS ACHIEVED A STATE LEVEL "U" CERTIFICATION. SUBCONTRACTING OF SUCH WORK TO PERSONS OR FIRMS NOT CURRENTLY LICENSED AS A FIRE PROTECTION SPRINKLER SYSTEM CONTRACTOR IS PROHIBITED UNDER WAC 212-80. FIRE PROTECTION NOTES 1.FIRE LINES SHALL BE RESTRAINED JOINTS AND PROVIDE THRUST BLOCKS AT ALL FITTINGS. 2.THE FIRE PROTECTION SYSTEM INCLUDING MATERIALS, SIZING, AND CONFIGURATION IS SUBJECT TO A CONTRACTOR PROVIDED DESIGN BY A FIRE PROTECTION ENGINEER, AND AS SUCH, THE FINAL DESIGN OF THE FIRE PROTECTION SYSTEM MAY DEVIATE FROM THE SYSTEM SHOWN. THE FIRE PROTECTION SYSTEM AS SHOWN FROM THE MAIN LINE TO THE CONNECTION AT THE BUILDING SPRINKLER IS INTENDED FOR LOCATION OF THE FIRE HYDRANTS AND FIRE DEPARTMENT CONNECTION ONLY. CONTRACTOR'S BID SHALL REFLECT THE CONDITIONS OF THE FIRE PROTECTION ENGINEER'S DESIGN. 3.CONTRACTOR SHALL COMPLY WITH ALL NATIONAL FIRE PROTECTION ASSOCIATION REQUIREMENTS AS SET FORTH BY "NFPA 13", ITS AMENDMENTS, AND LOCAL REQUIREMENTS, INCLUDING BUT NOT LIMITED TO ACQUISITION OF ALL PERMITS. 4.ALL VALVES ON FIRE LINE SHALL BE MONITORED BY THE FIRE CONTROL PANEL. 1 2 3 4 TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 253.383.2572 FAX 28 SKML/EAML/EA 10/18/2021 CIVIL PERMIT SET 2210016.10 PO BOX 597 PUYALLUP, WA 98371 JERRY SCHUUR SCHUUR BROTHERS CONSTRUCTION TAHOMA BOULEVARD APARTMENTS A PORTION OF THE NW 1/4 OF THE SE 1/4 OF SEC. 24, TWN. 17 N., RGE. 01 E. W.M. CITY OF YELM, THURSTON COUNTY, WASHINGTON. TAHOMA BOULEVARD APARTMENTS DATE: October 4, 2021 FILENAME: Q:\2021\2210016\10_CIV\CAD\_Site Development\2210016-SH-UTIL.dwg C4.2 17 WATER PLAN AND PROFILE N GRAPHIC SCALE 0 30 60 1" = 30 FEET 15 WATER CONSTRUCTION KEYNOTES NGRAPHIC SCALE 0 30 60 1" = 30 FEET 15 UTILITY CROSSING TABLE TOP UTILITY BOTTOM BOTTOM UTILITY CROWN SEPARATION STA WATER: 340.97 STORM: 341.50 0.53-FT 2+92.65 WATER: 340.68 STORM: 341.54 0.86-FT 3+04.25 WATER: 340.63 STORM: 341.13 0.50-FT 3+68.54 WATER: 340.53 STORM: 341.08 0.55-FT 4+71.71 WATER: 342.39 STORM: 343.09 0.70-FT 11+35.64 WATER: 342.40 STORM: 342.90 0.50-FT 10+19.25 J K L M N O J K L M N O NORTH DRIVE AISLE - WEST TO EAST V: 1" = 3' | H: 1" = 30' EAST DRIVE AISLE - SOUTH TO NORTH V: 1" = 3' | H: 1" = 30' REFER TO C4.1 FOR DESIGN INFORMATION REFER TO C4.3 FOR DESIGN INFORMATION 28 29 30 31 32 32 33 CONTINUATION PER SHEET C4.1 CONTINUATION THIS SHEET CONTINUATION PER SHEET C4.3 CONTINUATION THIS SHEET 26 27 26 32 2" DOMESTIC SERVICE CONNECTION W/ RPBA 28 FINISHED GRADE AT DRIVE AISLE CENTERLINE EXISTING GRADE AT DRIVE AISLE CENTERLINE 1 - 2" 45° BEND (MJ) CONC. THRUST BLOCKING PROPOSED 12" STORM SEE SHEET C3.3 1.5' MIN 91 LF 8" PVC C900 144 LF 8" PVC C900 33 32 PROPOSED 12" STORM SEE SHEET C3.3 264 LF 8" PVC C900 FINISHED GRADE AT DRIVE AISLE CENTERLINE EXISTING GRADE AT DRIVE AISLE CENTERLINE 4-3 C4.7 4-17 C4.9 4-3 C4.7 4-17 C4.9 10/19/2021 340 345 350 340 345 350 20+50FG 346.9021+00FG 346.6921+50FG 346.4422+00FG 347.0422+50FG 346.3823+00FG 346.7323+50FG 23+71.29FGFG 347.04FG 346.82FG 346.44FG 346.77FG 346.71FG 346.48FG 346.78EXISTING GRADE ELEVATION AT DRIVE AISLE CENTERLINE PROPOSED GRADE ELEVATION AT DRIVE AISLE CENTERLINE 264 LF 8" PVC C900 13LF 8" PVC C900 13 LF 8" PVC C900 3 4 7 10'15'347 34734 7 347 347 347 10+0021+00 22+00 23+00 264 LF 8" PVC C900 13 LF 8" PVC C900 33 34 35 36 37 1 - 8" 90° BEND (MJ) CONC. THRUST BLOCKING N 594613.59 E 1111012.02 1 - 8"x6" TEE (MJxFL) 1 - 6" GATE VALVE (FL) 13 LF 6" DI CL52 1 - HYDRANT ASSEMBLY CONC. THRUST BLOCKING N 594613.87 E 1110999.95 CENTER FIRE HYDRANT ASSEMBLY N 594606.29 E 1110999.76 CENTER FIRE DEPARTMENT CONNECTION N 594600.48 E 1111007.11 1 - 8"x6" TEE (MJxFL) 1 - 6" GATE VALVE (FL) 1 - POST INDICATOR VALVE (FL) 1 - 6" DDCVA CONC. THRUST BLOCKING N 594614.30 E 1110987.19 38 39 40 41 42 43 2" DOMESTIC SERVICE CONNECTION WITH RPBA N 594618.26 E 1110833.56 E 1111007.11 1 - 6" 90° BEND (MJ) CONC. THRUST BLOCKING N 594601.25 E 1110977.04 1 - 6" 90° BEND (MJ) CONC. THRUST BLOCKING N 594582.52 E 1110986.36 CENTER POST INDICATOR VALVE N 594582.67 E 1110980.85 1 - 6" 90° BEND (MJ) CONC. THRUST BLOCKING N 594583.29 E 1110963.90 2" DOMESTIC SERVICE CONNECTION WITH RPBA N 594614.98 E 1110958.91 FIRE SPRINKLER NOTE THE FIRE SPRINKLER UNDERGROUND PIPING SHOWN ON THESE PLANS SHALL BE CONSIDERED FOR LOCATION PURPOSES ONLY. APPROVAL OF THE CIVIL PLANS DOES NOT CONSTITUTE OR IMPLY APPROVAL FOR INSTALLATION OF THE FIRE SPRINKLER UNDERGROUND PIPING. A SEPARATE PERMIT IS REQUIRED FOR THE INSTALLATION OF THE FIRE SPRINKLER UNDERGROUND PIPING. PLANS AND SPECIFICATIONS FOR THE UNDERGROUND LEAD-IN PIPING SHALL BE SUBMITTED TO THE CITY OF YELM BUILDING DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. ALL WORK ON THE UNDERGROUND PORTIONS OF FIRE PROTECTION SPRINKLER SYSTEMS AND/OR FIRE MAIN FOR HYDRANT PLACEMENT MUST BE INSTALLED AND CERTIFIED BY A LICENSED CONTRACTOR WHO HAS ACHIEVED A STATE LEVEL "U" CERTIFICATION. SUBCONTRACTING OF SUCH WORK TO PERSONS OR FIRMS NOT CURRENTLY LICENSED AS A FIRE PROTECTION SPRINKLER SYSTEM CONTRACTOR IS PROHIBITED UNDER WAC 212-80. FIRE PROTECTION NOTES 1.FIRE LINES SHALL BE RESTRAINED JOINTS AND PROVIDE THRUST BLOCKS AT ALL FITTINGS. 2.THE FIRE PROTECTION SYSTEM INCLUDING MATERIALS, SIZING, AND CONFIGURATION IS SUBJECT TO A CONTRACTOR PROVIDED DESIGN BY A FIRE PROTECTION ENGINEER, AND AS SUCH, THE FINAL DESIGN OF THE FIRE PROTECTION SYSTEM MAY DEVIATE FROM THE SYSTEM SHOWN. THE FIRE PROTECTION SYSTEM AS SHOWN FROM THE MAIN LINE TO THE CONNECTION AT THE BUILDING SPRINKLER IS INTENDED FOR LOCATION OF THE FIRE HYDRANTS AND FIRE DEPARTMENT CONNECTION ONLY. CONTRACTOR'S BID SHALL REFLECT THE CONDITIONS OF THE FIRE PROTECTION ENGINEER'S DESIGN. 3.CONTRACTOR SHALL COMPLY WITH ALL NATIONAL FIRE PROTECTION ASSOCIATION REQUIREMENTS AS SET FORTH BY "NFPA 13", ITS AMENDMENTS, AND LOCAL REQUIREMENTS, INCLUDING BUT NOT LIMITED TO ACQUISITION OF ALL PERMITS. 4.ALL VALVES ON FIRE LINE SHALL BE MONITORED BY THE FIRE CONTROL PANEL. 1 2 3 4 TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 253.383.2572 FAX 28 SKML/EAML/EA 10/18/2021 CIVIL PERMIT SET 2210016.10 PO BOX 597 PUYALLUP, WA 98371 JERRY SCHUUR SCHUUR BROTHERS CONSTRUCTION TAHOMA BOULEVARD APARTMENTS A PORTION OF THE NW 1/4 OF THE SE 1/4 OF SEC. 24, TWN. 17 N., RGE. 01 E. W.M. CITY OF YELM, THURSTON COUNTY, WASHINGTON. TAHOMA BOULEVARD APARTMENTS DATE: October 4, 2021 FILENAME: Q:\2021\2210016\10_CIV\CAD\_Site Development\2210016-SH-UTIL.dwg C4.3 18 WATER PLAN AND PROFILE N GRAPHIC SCALE 0 30 60 1" = 30 FEET 15 WATER CONSTRUCTION KEYNOTES UTILITY CROSSING TABLE TOP UTILITY BOTTOM BOTTOM UTILITY CROWN SEPARATION STA WATER: 343.21 STORM: 343.75 0.54-FT 22+52.95 WATER: 343.21 STORM: 343.76 0.55-FT 21+43.58 P Q PQ FINISHED GRADE AT DRIVE AISLE CENTERLINEEXISTING GRADE AT DRIVE AISLE CENTERLINE PROPOSED 12" STORM SEE SHEET C3.3 (TYP) 12(REFER TO SHEET C4.1) 33 34 35 36 37 41 38 39 40 42 43 CONTINUATION PER MECHANICAL 12 (REFER TO SHEET C4.1) 35 34 33 2" DOMESTIC SERVICE CONNECTION W/ RPBA 2" DOMESTIC SERVICE CONNECTION W/ RPBA 13 LF 8"PVC C900 CONTINUATION PER SHEET C4.1 CONTINUATION PER SHEET C4.1 CONTINUATION PER SHEET C4.2 32 LF 6" DI CL52 31 LF 6" DI CL52 5 LF 6" DI CL525 LF 6" DI CL52 10 LF 6" DI CL52 17 LF 6" DI CL52 4-3 C4.7 4-17 C4.9 4-3 C4.7 4-17 C4.9 4-3 C4.7 4-17 C4.9 4-3 C4.7 4-17 C4.9 4-4 C4.9 4-7 C4.8 4-4.4 C4.7 10/19/2021 DATE: October 4, 2021 FILENAME: Q:\2021\2210016\10_CIV\CAD\_Site Development\2210016-SH-UTIL-DTLS.dwg C4.4 19 SEWER NOTES AND DETAILS 1 2 3 4 TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 253.383.2572 FAX 28 SKML/EAML/EA 10/18/2021 CIVIL PERMIT SET 2210016.10 PO BOX 597 PUYALLUP, WA 98371 JERRY SCHUUR SCHUUR BROTHERS CONSTRUCTION TAHOMA BOULEVARD APARTMENTS A PORTION OF THE NW 1/4 OF THE SE 1/4 OF SEC. 24, TWN. 17 N., RGE. 01 E. W.M. CITY OF YELM, THURSTON COUNTY, WASHINGTON. TAHOMA BOULEVARD APARTMENTS 1 NOT TO SCALE 2000 GAL STEP TANK 2 NOT TO SCALE 3000 GAL STEP TANK 10/19/2021 DATE: October 4, 2021 FILENAME: Q:\2021\2210016\10_CIV\CAD\_Site Development\2210016-SH-UTIL-DTLS.dwg C4.5 20 SEWER NOTES AND DETAILS 1 2 3 4 TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 253.383.2572 FAX 28 SKML/EAML/EA 10/18/2021 CIVIL PERMIT SET 2210016.10 PO BOX 597 PUYALLUP, WA 98371 JERRY SCHUUR SCHUUR BROTHERS CONSTRUCTION TAHOMA BOULEVARD APARTMENTS A PORTION OF THE NW 1/4 OF THE SE 1/4 OF SEC. 24, TWN. 17 N., RGE. 01 E. W.M. CITY OF YELM, THURSTON COUNTY, WASHINGTON. TAHOMA BOULEVARD APARTMENTS 1.ALL STEP TANKS HOUSING MORE THAN ONE PUMP MUST UTILIZE 2 INCH PIPING FOR THE SERVICE LINE. PROVIDE ORENCO MODEL P20 05 11 OR APPROVED EQUAL. PUMPS SHALL BE LISTED BY AN APPROVED TESTING LABORATORY E.G., UL OR CSA FOR USE AS AN EFFLUENT PUMP. PUMPS SHALL BE STAINLESS STEEL AND / OR THERMOPLASTIC. ALL WETTED FASTENERS SHALL BE 300-SERIES STAINLESS STEEL. 2.MOTORS MOTORS SHALL BE PERMANENT SPLIT PHASE-TYPE OPERATING AT 3450 RPM. MOTORS SHALL BE 1/2 HP, 115 VOLT, SINGLE PHASE, 60 HZ. THE SUPPLIER SHALL PROVIDE A HEAD CURVE SHOWING PERFORMANCE OF THE PUMP WITH THE ORIFICE INSTALLED. MOTORS SHALL BE THERMALLY-PROTECTED WITH AN AUTOMATIC-RESET FEATURE. 3.OPERATING CONDITIONS THE EFFLUENT PUMP SHALL BE OF THE SUBMERSIBLE TURBINE TYPE CAPABLE OF DELIVERING 20 GPM AGAINST A TDH OF 105 FEET, AND WITH A SHUT-OFF HEAD OF NOT LESS THAN 160 FEET. 4.BYPASS A 1/8" BYPASS ORIFICE SHALL BE DRILLED IN THE DISCHARGE HEAD OF THE PUMP TO ALLOW FOR COOLING PUMP MOTOR DURING PERIODS OF NO DISCHARGE. PUMP NOTES DUPLEX PUMP SYSTEMS AND TRIPLEX PUMP SYSTEMS FOR 3,000 GALLON TANKS OR LARGER 1.CALCULATIONS ASSUME POWER TRANSFER SWITCH IS INSTALLED 2.SEE SIZING INFORMATION ON SHEET C4.0 STEP TANK CALCULATIONS 10/19/2021 1 2 3 4 TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 253.383.2572 FAX 28 SKML/EAML/EA 10/18/2021 CIVIL PERMIT SET 2210016.10 PO BOX 597 PUYALLUP, WA 98371 JERRY SCHUUR SCHUUR BROTHERS CONSTRUCTION TAHOMA BOULEVARD APARTMENTS A PORTION OF THE NW 1/4 OF THE SE 1/4 OF SEC. 24, TWN. 17 N., RGE. 01 E. W.M. CITY OF YELM, THURSTON COUNTY, WASHINGTON. TAHOMA BOULEVARD APARTMENTS DATE: October 4, 2021 FILENAME: Q:\2021\2210016\10_CIV\CAD\_Site Development\2210016-SH-UTIL-DTLS.dwg C4.6 21 SEWER NOTES AND DETAILS A.ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH CITY OF YELM STANDARDS AND THE MOST CURRENT COPY OF THE STATE OF WASHINGTON STANDARD SPECIFICATIONS FOR ROAD BRIDGE AND MUNICIPAL CONSTRUCTION (WSDOT/APWA). B.ALL APPROVALS AND PERMITS REQUIRED BY THE CITY OF YELM SHALL BE OBTAINED BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. C.IF CONSTRUCTION IS TO TAKE PLACE IN THE COUNTY RIGHT-OF-WAY, THE CONTRACTOR SHALL NOTIFY THE COUNTY AND OBTAIN ALL THE REQUIRED APPROVALS AND PERMITS. D.A PRECONSTRUCTION MEETING SHALL BE HELD WITH THE CITY OF YELM PRIOR TO THE START OF CONSTRUCTION. E.THE CITY OF YELM SHALL BE NOTIFIED A MINIMUM OF 48 HOURS IN ADVANCE OF A TAP CONNECTION TO AN EXISTING MAIN, A CITY REPRESENTATIVE SHALL BE PRESENT AT THE TIME OF THE TAP. F.THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE LOCATION AND PROTECTION OF ALL EXISTING UTILITIES. THE CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION BY CALLING THE UNDERGROUND LOCATE LINE AT 1-800-424-5555 A MINIMUM OF 48 HOURS TO PRIOR TO ANY EXCAVATION. G.SIDE SEWER SERVICES SHALL BE PVC, ASTM D 3034 SDR 35 WITH FLEXIBLE GASKETED OR SOLVENT WELD JOINTS. H.ALL PLASTIC PIPE AND SERVICES SHALL BE INSTALLED WITH CONTINUOUS TRACER TAPE, INSTALLED 12" TO 8" UNDER THE PROPOSED SUBGRADE. THE MARKER SHALL BE PLASTIC NON-BIODEGRADABLE, METAL CORE OR BACKING MARKED "SEWER" WHICH CAN BE DETECTED BY A STANDARD METAL DETECTOR. IN ADDITION, STEP SYSTEM AND FORCE MAINS SHALL BE INSTALLED WITH 14 GAUGE, HEAVY COATED UF DIRECT-BURY COPPER WIRE WRAPPED AROUND ALL PLASTIC PIPE, BROUGHT UP AND TIED OFF AT VALVE BODY. TAPE SHALL BE TERRA TAPE "D" OR APPROVED EQUAL. THE AND WIRE SHALL BE FURNISHED BY THE CONTRACTOR. I.ALL BURIED POWER FOR STEP SYSTEMS SHALL BE INSTALLED WITH CONTINUOUS TRACER TAPE INSTALLED 12" ABOVE THE BURIED POWER. THE MARKER SHALL BE PLASTIC NON-BIODEGRADABLE, METAL CORE BACKING MARKED "POWER". TAPE SHALL BE FURNISHED BY CONTRACTOR. J.BEDDING OF THE SEWER MAIN AND ALL APPURTENANCES SHALL BE SAND AND COMPACTION OF THE BACKFILL MATERIAL SHALL BE REQUIRED IN ACCORDANCE WITH THE ABOVE MENTIONED SPECIFICATION (SEE GENERAL NOT 5.60-A) K.TEMPORARY STREET PATCHING SHALL BE ALLOWED FOR AS APPROVED BY THE CITY ENGINEER. TEMPORARY STREET PATCHING SHALL BE PROVIDED BY PLACEMENT AND COMPACTION OF 2 INCH MINIMUM ASPHALT CONCRETE COLD MIX. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTENANCE AS REQUIRED. L.EROSION CONTROL MEASURES SHALL BE TAKEN BY THE CONTRACTOR DURING CONSTRUCTION TO PREVENT INFILTRATION OF EXISTING AND PROPOSED STORM DRAINAGE FACILITIES AND ROADWAYS. M.PROVIDE TRAFFIC CONTROL PLAN(S) IN ACCORDANCE WITH THE MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) AS REQUIRED. N.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO HAVE A COPY OF THESE APPROVED PLANS ON CONSTRUCTION SITE AT ALL TIMES. O.ANY CHANGES TO THE DESIGN SHALL FIRST BE REVIEWED AND APPROVED BY THE CITY OF YELM. P.ALL STEP MAINS SHALL BE HYDROSTATICALLY TESTED IN CONFORMANCE WITH THE ABOVE-REFERENCED SPECIFICATION FOR TESTING WATER MAINS. (SEE NOTE 1). IN ADDITION, ALL STEP MAINS SHALL BE PIGGED/CLEANED IN THE PRESENCE OF THE CITY INSPECTOR PRIOR TO PLACING STEP MAIN IN SERVICE. Q.PRIOR TO BACKFILL ALL MAINS AND APPURTENANCES SHALL BE INSPECTED AND APPROVED BY THE CITY OF YELM. APPROVAL SHALL NOT RELIEVE THE CONTRACTOR FOR CORRECTION OF ANY DEFICIENCIES AND/OR FAILURES AS DETERMINED BY SUBSEQUENT TESTING AND INSPECTIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE CITY OF YELM FOR THE REQUIRED INSPECTIONS. R.PUMP CONTROL PANELS SHALL BE LOCATED ON GARAGE WALL OR REMOTE POST, 5-FEET FROM TOP OF PANEL TO FINISH GRADE, UNLESS OTHERWISE AUTHORIZED BY THE CITY OF YELM. S.IN THE EVENT THAT THE DEPARTMENT OF LABOR AND INDUSTRIES OR THE CITY SHOULD REQUIRE AS SEPARATE "ON-OFF" SWITCH CONTROLLING POWER TO THE PUMP CONTROL PANEL, SAID SWITCH SHALL HAVE A LOCKING COVER MODEL #5031-0 RAYNITE SINGLE GANG WEATHERPROOF COVER 1.406" DIAMETER. T.INSPECTIONS FOR ONSITE STEP INSTALLATIONS ARE REQUIRED. A 48-HOUR NOTICE TO THE SEWER DEPARTMENT IS REQUIRED PRIOR TO THE INSPECTION. ITEMS NEEDING INSPECTION ARE: T.A.TANK INSTALLATION, IE; BEDDING AND LOCATION T.B.TANK INFILTRATION, EXFILTRATION TEST T.C.S.S. PRESSURE TEST T.D.SERVICE LINE PRESSURE TEST T.E.FINAL INSPECTION U.ALL POSTS USED TO SUPPORT CONTROL PANELS MUST BE HOT DIP GALVANIZED UNISTRUT OR APPROVED EQUAL. GENERAL NOTES (SANITARY SEWER MAIN INSTALLATION) 10/19/2021 1 2 3 4 TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 253.383.2572 FAX 28 SKML/EAML/EA 10/18/2021 CIVIL PERMIT SET 2210016.10 PO BOX 597 PUYALLUP, WA 98371 JERRY SCHUUR SCHUUR BROTHERS CONSTRUCTION TAHOMA BOULEVARD APARTMENTS A PORTION OF THE NW 1/4 OF THE SE 1/4 OF SEC. 24, TWN. 17 N., RGE. 01 E. W.M. CITY OF YELM, THURSTON COUNTY, WASHINGTON. TAHOMA BOULEVARD APARTMENTS DATE: October 4, 2021 FILENAME: Q:\2021\2210016\10_CIV\CAD\_Site Development\2210016-SH-UTIL-DTLS.dwg C4.7 22 WATER NOTES AND DETAILS GENERAL NOTES (WATER MAIN INSTALLATION) 1 NOT TO SCALE TYPICAL UTILITY CROSSING 10/19/2021 1 2 3 4 TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 253.383.2572 FAX 28 SKML/EAML/EA 10/18/2021 CIVIL PERMIT SET 2210016.10 PO BOX 597 PUYALLUP, WA 98371 JERRY SCHUUR SCHUUR BROTHERS CONSTRUCTION TAHOMA BOULEVARD APARTMENTS A PORTION OF THE NW 1/4 OF THE SE 1/4 OF SEC. 24, TWN. 17 N., RGE. 01 E. W.M. CITY OF YELM, THURSTON COUNTY, WASHINGTON. TAHOMA BOULEVARD APARTMENTS DATE: October 4, 2021 FILENAME: Q:\2021\2210016\10_CIV\CAD\_Site Development\2210016-SH-UTIL-DTLS.dwg C4.8 23 WATER NOTES AND DETAILS 10/19/2021 1 2 3 4 TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL www.ahbl.comWEB TACOMA SEATTLE SPOKANE TRI-CITIES Know what's below. before you dig.Call R 253.383.2572 FAX 28 SKML/EAML/EA 10/18/2021 CIVIL PERMIT SET 2210016.10 PO BOX 597 PUYALLUP, WA 98371 JERRY SCHUUR SCHUUR BROTHERS CONSTRUCTION TAHOMA BOULEVARD APARTMENTS A PORTION OF THE NW 1/4 OF THE SE 1/4 OF SEC. 24, TWN. 17 N., RGE. 01 E. W.M. CITY OF YELM, THURSTON COUNTY, WASHINGTON. TAHOMA BOULEVARD APARTMENTS DATE: October 4, 2021 FILENAME: Q:\2021\2210016\10_CIV\CAD\_Site Development\2210016-SH-UTIL-DTLS.dwg C4.9 24 WATER NOTES AND DETAILS 10/19/2021