21-005 Stevens 4-Plex Equip Sub 10-12KNIGHT FIRE PROTECTION, INC. 9702 LATHROP INDUSTRIAL DR. SW OLYMPIA, WA 98512-9188 (360) 786-8606 FAX 786-8722 LICENSE NO. KNIGHFP044LK Fire Sprinkler System Equipment Submittal Stevens 4-Plex 314 Stevens Ave. NE Yelm, WA 98597 KFP Job #21-005 KFP Job #12-113 Model RFC Cover Plate Model RFC43 & RFC43LLModel RFC30 & RFC30LL Model RFC49 & RFC49LL Model RFC58 Model RFC Series Residential Sprinklers Flat Cover Plate, Concealed Pendent Sprinkler cULus Listed Bulletin 006 Rev. L June 2018 Features • cULus Listed as Residential Sprinklers • Push-On cover plate installation • Low water flow requirements Product Description Model RFC Series residential sprinklers are flat cover plate, concealed pendent sprinklers intended for installation in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The sprinklers are cULus Listed as Residential Sprinklers in ac- cordance with UL 1626. In addition, Model RFCLL Series sprinklers are cULus Certified for Health Effects to NSF/ANSI standard 61 Annex G (LL). Model RFC30, RFC43, and RFC49 sprinklers have a 165°F (74°C) temperature rated fusible-link operating element. Model RFC58 and RFC76 sprinklers are offered with either a 165°F (74°C) or 212°F (100°C) temperature rated fusible-link operating element. Sprinklers with a 165°F (74°C) tempera- ture rating are ordinary temperature classification and are listed for use with a 135°F (57°C) temperature rated cover plate. Sprinklers with a 212°F (100°C) temperature rating are intermediate temperature classification and are listed for use with a 165°F (74°C) temperature rated cover plate. Model RFC Series sprinklers are installed with a Model RFC cover plate. Model RFC cover plates may be installed by ei- ther pushing or threading the cover plate into the sprinkler cup. Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49 and RFC49LL sprinklers allow 1/2” (13 mm) of cover plate adjust- ment. Model RFC58 and RFC76 sprinklers allow 3/4” (19 mm) of cover plate adjustment. Model RFC cover plates are avail- able in a variety of finishes as listed in Table H. www.reliablesprinkler.com Sprinkler Model Nominal K-Factor gpm/psi1/2 (l/min/bar1/2) Max. Coverage Area ft x ft (m x m) Listings & Approvals Sprinkler Identification Number (SIN) RFC30 3.0 (43)14 x 14 (4.3 x 4.3)cULus RA0611 RFC30LL 3.0 (43)14 x 14 (4.3 x 4.3)cULus, LL RA3211 RFC43 4.3 (62)20 x 20 (6.1 x 6.1)cULus RA0612 RFC43LL 4.3 (62)20 x 20 (6.1 x 6.1)cULus, LL RA3212 RFC49 4.9 (71)20 x 20 (6.1 x 6.1)cULus RA0616 RFC49LL 4.9 (71)20 x 20 (6.1 x 6.1)cULus, LL RA3216 RFC58 5.8 (84)20 x 20 (6.1 x 6.1)cULus RA0613 RFC76 7.6 (109)20 x 20 (6.1 x 6.1)cULus RA0618 Table A cULus: cULus Listed to UL1626, Residential Sprinklers for Fire Protection Service. LL: cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (Less than 0.25% Lead content). Model RFC76 Technical Specifications Style: Flat Concealed Pendent Threads: 1/2” NPT or ISO 7-1R1/2 Nominal K-Factor: 4.9 (71 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Rating 165°F (74°C) sprinkler 135°F (57°C) cover plate Cover Plate Model RFC cover plate Sprinkler Wrench Model FC Listings and Approvals cULus Listed to UL 1626 cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC49LL only) Model RFC49 & RFC49LL Sprinkler Components and Dimensions Figure 3 Model RFC49 & RFC49LL Sprinkler Hydraulic Design Criteria Table D Minimum Flow and Residual Pressure (1) Max. Coverage Area (2) ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar) 16 x 16 (4.9 x 4.9) 13 (49.0) 7.0 (0.48) 18 x 18 (5.5 x 5.5) 17 (64.3) 12.0 (0.83) 20 x 20 (6.1 x 6.1) 20 (75.7) 16.7 (1.15) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table D above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Rev. L June 2018 Page 4 of 8 www.reliablesprinkler.com Bottom View Model RFC49 & RFC49LL Residential Sprinklers RFC49: SINRA0616 RFC49LL: SINRA3216 Model RFC58 Residential Sprinkler SIN RA0613 Technical Specifications Style: Flat Concealed Pendent Threads: 1/2” NPT or ISO 7-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Chrome Plated Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Ratings Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model RFC Cover Plate Sprinkler Wrench Model FC Listings and Approvals cULus Listed Model RFC58 Sprinkler Components and Dimensions Figure 4 Model RFC58 Sprinkler Hydraulic Design Criteria Table E Minimum Flow and Residual Pressure( 1) Max. Coverage Area (2) ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar) 16 x 16 (4.9 x 4.9) 16 (60.6) 7.6 (0.53) 18 x 18 (5.5 x 5.5) 18 (68.1) 9.6 (0.66) 20 x 20 (6.1 x 6.1) 20 (75.7) 11.9 (0.82) Bulletin 006 Rev. L June 2018 Page 5 of 8 www.reliablesprinkler.com Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table E above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bottom View Standard Finishes Special Application Finishes White Polyester Off White Paint Black Paint Raw Brass Chrome Plated Bright Brass Finished Bronze Black Plated Satin Chrome Stainless Steel Clad(3)Custom Color Paint(2) Notes: 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. 2. Custom color paint is semi-gloss, unless specified otherwise. 3. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the back side. Cover plates are not listed or approved as corrosion resistant. Stainless steel clad cover plates are not available perforated. Cover Plate Finishes(1) Table H Bulletin 006 Rev. L June 2018 Page 7 of 8 www.reliablesprinkler.com Notes: 1. Face of fitting to ceiling dimensions are based on a nominal thread make up. Verify dimensions based on fitting and thread sealing method prior to installation. A 1/2” x 1/2” brass nipple extension (Reliable P/N 6999991900) is available where necessary for replacement of existing sprinklers. 2. For use with 165°F (74°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F (38°C). 3. For use with 212°F (100°C) temperature rated sprinklers with the Maximum Ceiling Temperature does not exceed 150°F (66°C). Sprinkler Model Cover Plate Model Cover Plate Diameter inch (mm) Recommended Hole Diameter in Ceiling inch (mm) Cover Plate Adjustment inch (mm) Min. to Max. Face of Fitting to Ceiling(1) inch (mm) Min. to Max. Dropped Deflector Distance below Ceiling inch (mm) Cover Plate Temperature Rating RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL RFC 3-5/16 (84) 2-5/8 (67) 1/2 (13) 1-1/2 to 2 (38 to 51) 1/2 to 1 (13 to 25) 135°F (57°C) RFC58, RFC76 RFC 3-5/16 (84) 2-5/8 (67) 3/4 (19) 1-1/2 to 2-1/4 (38 to 57) 1/4 to 1 (6 to 25) 135°F(2) (57°C) or 165°F(3) (74°C) Table JInstallation Dimensions Installation Model RFC series sprinklers are intended to be installed in ac- cordance with NFPA 13, NFPA 13R, or NFPA 13D, as well as the requirements of applicable authorities having jurisdiction. Mod- el RFC series sprinklers must not be installed in ceilings with positive pressure in the space above. Ensure that the 4 slots in the cup are open and unobstructed following installation. Model RFC series sprinklers are shipped with a protective cap that should remain on the sprinkler until installed. The protective cap should be replaced following installation of the sprinkler and permanently removed only when the cover plate is installed and the sprinkler system is placed in service following construction. Model RFC series sprinklers are installed with the Model FC wrench. The use of any other wrench to installed Model RFC se- ries sprinklers is not permitted and may damage the sprinkler. Temporarily remove the protective cap during installation of the sprinkler. Insert the Model FC wrench over the sprinkler until the wrench engages the body. Do not wrench any other part of the sprinkler/cup assembly. The Model FC wrench is designed to be turned with a standard 1/2” square drive. Tighten the sprin- kler into the fitting after applying a PTFE based thread sealant to the sprinkler’s threads. Recommended installation torque is 8 to 18 ft-lbs (11 to 24 N-m) for 1/2” thread sprinklers and 14 to 20 ft-lbs (19 to 27 N-m) for 3/4” thread sprinklers. Do not exceed the maximum recommended torque. Exceeding the maximum recommended torque may cause leakage or im- pairment of the sprinkler. Use care when inserting or removing the wrench from the sprinkler to avoid damage to the sprinkler. Install the cover plate by hand by pushing the cover plate into the cup and turning the cover in the clockwise direction until it is tight against the ceiling. Application Model RFC series sprinklers are intended for installation where residential sprinklers are permitted or required by NFPA 13, NFPA 13R, and NFPA 13D. The sprinklers are concealed pen- dent residential sprinklers. Model RFC 30, RFC30LL, RFC43, RFC43LL, RFC49 and RFC49 LL sprinklers are available in ordinary temperature classifica- tion for installation where the Maximum Ceiling Temperature does not exceed 100°F (38°C). Model RFC58 and RFC76 sprin- klers are available in either ordinary or intermediate tempera- ture classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (38°C) or 150°F (66°C), respectively. Guarantee For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, and RFC76 sprinklers are covered by U.S. Patent No. 9,248,327 and U.S. Patent No. 7,275,603. Model RFC30, RFC30LL, RFC43 and RFC43LL sprinklers are additionally covered by U.S. Patent No. 8,776,903. Ordering Information Specify the following when ordering. Sprinkler • Model (RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, RFC76) • Temperature Rating Cover Plate • Model RFC • Temperature Rating • Finish (See Table H) Sprinkler Wrench • Model FC Maintenance Model RFC series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by gentle vacuuming. Replace any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-oper- ation. Bulletin 006 Rev. L June 2018 Page 8 of 8 www.reliablesprinkler.com Model FC Listings and Approvals Listed by Underwriters Laboratories, Inc. and UL Certified for Canada to UL1626, Residential Sprinklers for Fire-protection Service (cULus). Certified by Underwriters Laboratories, Inc. and Underwriters Laboratories of Canada for Health Effects to NSF/ANSI Standard 61 Annex G (LL) (RFC30LL, RFC43LL, and RFC49LL only). Wrench P/N 9999970261 Features • cULus Listed Residential Sprinklers • Available in pendent and horizontal sidewall orientations • Decorative finishes available, including recessed escutcheons and conical concealed cover plates Product Description Model F1Res Series sprinklers are residential sprinklers with a 3 mm glass bulb operating element. A variety of K-Factors as well as recessed and conical concealed options are available as detailed in this Bulletin. The F1Res Series sprinklers are specially engineered for fast thermal response to meet the requirements of UL 1626. They are intended for installation in accordance with NFPA 13, 13R, and 13D. Application The Model F1Res Series sprinklers cULus Listed Residential sprinklers are intended for use in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The Model F1Res residential sprinklers are cULus Listed for use in residential occupancies and residential portions of any occupancy, where permitted by NFPA 13, NFPA 13R, or NFPA 13D. For NFPA 13R and NFPA 13D applications, the design flow and pressure shall not be less than the minimum flow and pressure specified in the Listed Design Criteria tables in this Bulletin. For NFPA 13 applications, www.reliablesprinkler.com Residential Sprinkler Summary Sprinkler Model Sprinkler Identification Number (SIN) Orientation K-Factor gpm/psi1/2 (lpm/bar1/2) Thread Size NPT or ISO7-1 Installation Options Max. Coverage Area ft x ft (m x m) F1Res30 R3511 Pendent 3.0 (43)1/2 Pendent or Recessed 16 x16 (4.9 x 4.9) F1Res49 R3516 Pendent 4.9 (71)1/2 Pendent or Recessed 20 x 20 (6.1 x 6.1) F1Res58 R3513 Pendent 5.8 (84)1/2 Pendent or Recessed 20 x 20 (6.1 x 6.1) F1Res76 R7618 Pendent 7.6 (109)3/4 Pendent or Recessed 20 x 20 (6.1 x 6.1) F1Res30 CCP R3511 Pendent 3.0 (43)1/2 Conical Concealed 14 x 14 (4.3 x 4.3) F1Res49 CCP R3516 Pendent 4.9 (71)1/2 Conical Concealed 20 x 20 (6.1 x 6.1) F1Res58 CCP R3513 Pendent 5.8 (84)1/2 Conical Concealed 20 x 20 (6.1 x 6.1) F1Res76 CCP R7618 Pendent 7.6 (109)3/4 Conical Concealed 20 x 20 (6.1 x 6.1) F1Res44 HSW R3531 Horizontal Sidewall 4.4 (63)1/2 Recessed 16 x 20 (4.9 x 6.1) F1Res44 SWC R3531 Horizontal Sidewall 4.4 (63)1/2 Conical Concealed 16 x 20 (4.9 x 6.1) F1Res58 HSW R3533 Horizontal Sidewall 5.8 (84)1/2 Recessed 16 x 20 (4.9 x 6.1) F1Res 58 HSWX RA3533 Horizontal Sidewall 5.8 (84)1/2 Recessed 14 x 26 (4.3 x 7.9) Table A the design density shall be a minimum of 0.1 gpm/sf (4.1 mm/ min), but in no case shall the flow and pressure be less than the minimum flow and pressure specified in the Listed Design Criteria tables in this bulletin. Model F1Res Series sprinklers are listed for use in wet systems only. cULus Listed Model F1Res Series Glass Bulb Residential Sprinklers Bulletin 135 April 2021 Important Note: Model D wrench and Model GFR2 wrench are no longer compatible with this product. Model W2 (non- recessed) and Model W4 (recessed, concealed) are required. Note: Please note SIN difference between F1Res58 HSW (R3533) and F1Res58 HSWX (RA3533). Model F1Res44 Horizontal Sidewall Sprinkler & Models FV & F2 Recessed Escutcheon SIN R3531 Technical Specifications Style: Sidewall and Recessed Sidewall Threads: 1/2” NPT or ISO7-1R1/2 Nominal K-Factor: 4.4 (63 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast-response Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F2 Recessed FV Recessed Sprinkler Wrenches Model W2 Model W4 (Recessed) Minimum Flow and Residual Pressure in Wet Pipe Systems(1) Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7)12 (45)7.5 (0.52) 4 to 6 inches (100 to 150 mm) 14 x 14 (4.3 x 4.3)14 (53)10.2 (0.70) 15 x 15 (4.6 x 4.6) 15 (57)11.6 (0.80) 16 x 16 (4.9 x 4.9)16 (61)13.3 (0.92) 16 x 18 (4.9 x 5.5)18 (68)16.8 (1.16) 16 x 20 (4.9 x 6.1)23 (87)27.4 (1.89) 18 x 18 (5.5 x 5.5)19 (72)18.7 (1.29) 12 x 12 (3.7 x 3.7)14 (53)10.2 (0.7) 6 to 12 inches (150 to 300 mm) 14 x 14 (4.3 x 4.3)16 (61)13.2 (0.91) 15 x 15 (4.6 x 4.6)16 (61)13.2 (0.91) 16 x 16 (4.9 x 4.9)17 (64)15.0 (1.03) 16 x 18 (4.9 x 5.5)20 (76)20.7 (1.43) 16 x 20 (4.9 x 6.1)23 (87)27.4 (1.89) Model F1Res44 Horizontal Sidewall Sprinkler Hydraulic Design Criteria Table J Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Model F1Res44 Horizontal Sidewall Sprinkler Installation Dimensions Figure 9 Bulletin 135 April 2021 Page 10 of 15 www.reliablesprinkler.com Model W4 Model W2 Installation Models F1Res sprinklers are to be installed as shown in this bulletin. Model F1, F2, FV, and FP recessed escutcheons are the only recessed escutcheons to be used with Model F1Res sprinklers. Not all F1Res sprinklers may be used with all recessed escutcheons offered. Confirm listing of escutcheon type for use with individual sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model F1Res sprinklers, use only the Model W2 sprinkler Wrench; for installing Models F1Res Recessed Pendent, Sidewall, Conical Concealed Pendent (CCP), and Sidewall Concealed (SWC and SWC–2) sprinklers use only the Model W4 sprinkler wrench. Use of wrenches other than those specified may damage these sprinklers. Installation of F1Res sprinklers in a wall or ceiling will require a hole diameter of 2-1/4” (57 mm) for F1 or F2 recessed escutcheons; or 2-5/8” (67 mm) for FP recessed escutcheons, CCP, SWC, and SWC–2 cover plates. Install F1Res HSW sprinklers with a ceiling to deflector distance that complies with the hydraulic design criteria tables in this bulletin. The flow arrow on deflector must point away from near wall and “Top” marking must face the ceiling. A ‘leak tight” sprinkler joint can be obtained with the following torque: • 1/2” NPT and ISO7-1R1/2: 8-18 ft-lbs (11 – 24 N-m) • 3/4” NPT and ISO7-1R3/4: 14-20 ft-lbs (19 – 27 N-m) Do not tighten sprinklers over maximum recommended torque. This may cause leakage or impairment of the sprinklers. Do not install any glass bulb sprinklers where the bulb is cracked or there is a loss of liquid from the bulb. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. Remove this protection at the time the sprinkler system is placed in service. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when protectors are in place. Remove protectors by undoing the clasp by hand. Do not use tools to remove the protectors. Table N Standard Finishes Special Application Finishes Sprinkler(1)F1, F2. FV, FP(3), Escutcheons CCP, SWC (Conical) Cover Plates (1)Sprinkler (1)F1, F2. FV, FP(3), Escutcheons CCP, SWC (Conical) Cover Plates (1) Bronze Brass --Bright Brass Bright Brass Bright Brass Chrome Plated Chrome Plated Chrome Plated Dull Chrome Dull Chrome Dull Chrome White Polyester (2) White Polyester White Paint Black Polyester (2) Black Polyester Black Paint ------Custom Color Polyester Custom Color Polyester Custom Color Paint ------Electroless Nickel PTFE (2)---- Notes: (1) Paint or any other coating applied over the factory finish will void all approvals and warranties. (2) cULus Listed Corrosion Resistant. (3) The Model FP escutcheon assembly consists of an unfinished galvanized cup with a finished escutcheon ring. Finishes The Model W4 wrench includes two sets of jaws. One set of jaws is equivalent to a Model GFR2 wrench and the other set of jaws is equivalent to a Model W1 wrench. Use the smallest of the two sets of jaws that will fit on the sprinkler’s wrench flats. The Model W4 wrench is used in conjunction with the installer’s nominal 1/2” square drive ratchet and nominal 5” (125mm) long extension (not provided) as shown in Figure 13. Model W4 Wrench Installation Example Figure 13 Bulletin 135 April 2021 Page 14 of 15 www.reliablesprinkler.com P/N 9999970235Maintenance Reliable Model F1Res Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, 13, 13D, and 13R, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). Properly installed CCP, SWC, and SWC–2 cover plates will have an air gap that is required for proper operation, do not seal the gap or paint the cover plates. Replace any sprinkler which has been damaged, where cracks are observed in the glass bulb, or when liquid has been lost from the glass bulb. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non-operation during a fire event. Listings & Approvals Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Guarantee For Reliable Automatic Sprinkler Company guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents For patents applicable to products contained in this technical bulletin, please visit www.r-s.co Ordering Information Specify the following when ordering: Sprinkler • Model (See Table A) • Temperature Rating • Threads (NPT or ISO7-1) • Finish (See Table N) Escutcheon or Cover Plate • Model • Finish (See Table N) Sprinkler Wrench • Model W2 (Pendent and HSW) • W4 (Recessed and Concealed) Note: Please note SIN difference between F1Res58 HSW (R3533) and F1Res58 HSWX (RA3533). Bulletin 135 April 2021 Page 15 of 15 www.reliablesprinkler.com 5401152 - REV K • 2/15 PAGE 1 OF 3 Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-0988 / Customer Service: 866-572-3005 • www.pottersignal.com RD13 Residential Riser Description The RD13 Riser (with NPT connectors) is constructed from Listed CPVC products suitable for fire sprinkler services subject to the limitations and installation requirements of Flameguard® CPVC pipe and Spears® CPVC fittings. The RD13 Riser incorporates a VSR-SG flow switch, gauge, and drain/test valve. The VSR-SG flow switch is equipped with union connection to facilitate the installation and removal of the switch in confined spaces. Installation 1. Using appropriate sealant, thread the female adapter on to the main water supply. Then glue the riser assembly to the female adapter. Pipe the drain connection to an adequate drain location capable of handling the drain discharge. The riser can be mounted in the horizontal or vertical position. Direction of flow is indicated in Fig. 1. The waterflow switch must be located on the top or on the side of the pipe when installed in the horizontal position. This will prevent debris from entering the throat of the waterflow switch which could interfere with proper operation. 2. Following CPVC manufacturer’s instructions for preparation and gluing of CPVC piping systems, glue the main riser to the main supply line for the sprinkler heads. NOTE: All glued connections must be completed and cured before the flowswitch is installed. (Continued on page 2). Features • Pre-assembled and pressure tested • Available in 1”,1 1/4”, 1 1/2”, & 2” nominal pipe size models • Female adapter ships loose so riser can be installed in a confined space • Fits in standard 2X4 construction walls Specifications subject to change without notice Do not over-tighten the union nut, hand tighten only. Use of a wrench may cause damage to the union nut. • Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. • Shock hazard. Disconnect power source before servicing. Serious injury or death could result. • Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. Flow Switch Technical Specifications Dimensions See Fig 2 Service Pressure 175 PSI (12,07 BAR) - UL Flow Sensitivity Range for Signal 4-10 GPM (15-38 LPM) - UL Maximum Surge 18 FPS (5.5 m/s) Contact Ratings Two sets of SPDT (Form C) 10.0 Amps at 125/250VAC 2.0 Amps at 30VDC Resistive 10 mAmps min. at 24VDC Resistive 10 m Amps min. at 24V DC Environmental Limitations Temperature range: 40°F-120°F (4.5°C-49°C)-UL Conduit Entrances Two knockouts provided for 1/2” conduit Listings UL, CUL CSFM Listed, and CE Marked Service Use Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72British Standard BS9251 5401152 - REV K • 2/15 PAGE 2 OF 3 Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-0988 / Customer Service: 866-572-3005 • www.pottersignal.com RD13 Residential Riser Maintenance The VSR-SG waterflow switch should provide years of trouble-free service. The retard and switch assembly are easily field replaceable. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock number 1029030. There is no maintenance required, only periodic testing and inspection.. Removal • To prevent accidental water damage, all control valves should be shut tight and the system completely drained before waterflow detectors are removed or replaced. • Turn off electrical power to the detector, then disconnect wiring. • Loosen nut on union fitting. • Lift detector clear of pipe. Retard Adjustment The delay can be adjusted by rotating the retard adjustment knob from 0 to the max setting (60-90 seconds). The time delay should be set at the minimum required to prevent false alarms. Important: The paddles have raised lettering that show the pipe size and the TEE manufacturer they are to be used with. The proper paddle must be used. The paddle must be properly attached and the screw that holds the paddle must be securely tightened. Fig 1 Installation (Continued) 3. A thread sealant shall be used in making threaded connections. Teflon® thread tape is the recommended sealant. Some thread sealants other than Teflon thread tape contain solvents or other materials that may be damaging to CPVC. For other types of thread sealants, which have been specifically investigated and confirmed to be “System Compatible”, refer to www.spearsmfg.com. Attach gauge to riser. Apply Teflon® tape to male fitting of gauge only. See Fig 1. 4. Check to make sure the proper paddle is installed on the switch. (Paddle size must match the riser pipe size and Tee manufacture.) 5. Install the flow switch to the RD13 Riser. Verify that the o-ring is properly positioned in its groove. Hand tighten the nut to the union after orienting the flow switch in the appropriate direction to detect waterflow. The paddle must not rub the inside of the Tee or bind in any way. The stem should move freely when operated by hand. See Fig. 1. NOTE: Do not leave switch cover off for an extended period of time. 6. The side of flow switch must be perpendicular with the riser piping. See Fig. 3. Testing The frequency of inspection and testing for the Model VSR-SG and its associated protective monitoring system, should be in accordance with applicable Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently.) If provided, the inspector’s test valve (usually located at the end of the most remote branch line) should be used for test purposes. If there is no remote inspection test connection; a short length of hose may be connected to the discharge of the 1” drain line valve, or if the drain line is connected to a drain such as a slop sink or storm drain that will sufficiently handle the discharge of the main drain valve. The drain valve can be used to test the operation of the VSR-SG switch. A minimum flow of 10 GPM (38 LPM) is required to activate this switch. An orifice equal to the smallest sprinkler head orifice used in the system shall be attached to the drain line for testing purposes. Optional Cover Tamper Switch Mount so arrow on base points in direction of waterflow DO NOT LEAVE COVER OFF FOR EXTENDED PERIOD OF TIME Retard Adjusting Knob 1” Male Fitting on All Sizes Riser may be 1”, 1/4”, 1 1/2”, or 2” Waterfl o w 5401152 - REV K • 2/15 PAGE 3 OF 3 Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-0988 / Customer Service: 866-572-3005 • www.pottersignal.com RD13 Residential Riser Dimensions Orientation Fig 2 Fig 3 D C B A E F 90° 3 1/2” Gauge (Shipped Loose) 1” NPT Drain Valve VSR-SG Flow Switch NPT Adaptor (Shipped Loose) (See Chart Below) *RD13 Risers (ASSEMBLED DIMENSIONS) Riser Size Model Number Part Number Dimension “A” Dimension “B” Dimension "C" Dimension "D"Dimension "E" Dimension "F" (in.)(mm.)(in.)(mm.)(in.)(mm.)(in.)(mm.)(in.)(mm.)(in.)(mm.) 1"RD13-100-1 1119067 16 406 15 3/4 400 14 7/8 378 14 5/8 371 12 1/4 311 10 1/2 267 1 1/4"RD13-125-1 1119077 16 5/8 422 16 1/2 419 15 1/2 394 15 3/8 391 12 1/2 318 10 5/8 270 1 1/2"RD13-150-1 1119087 N/A N/A 16 3/4 425 N/A N/A 15 5/8 397 12 3/4 324 10 3/4 273 2"RD13-200-1 1119097 N/A N/A 18 1/4 464 N/A N/A 16 7/8 429 13 3/8 340 11 1/8 283 Flow switch must be properly orientated. Side of cover must be perpendicular with the pipe. Improper orientation could delay or prevent notification of waterflow. Ordering Information Ordering Information Nominal Pipe Size Model Part Number 1"RD13 Riser 1119067 1 1/4"RD13 Riser 1119077 1 1/2"RD13 Riser 1119087 2"RD13 Riser 1119097 Optional: Cover Tamper Switch Kit, stock no. 0090148 Replaceable Components: Retard/Switch Assembly, stock no. 1029030 Gauge, Flow Switch, and NPT Adapter shipped loose in box. BELLS PBA-AC & PDC-DC 5400777 - REV A • 12/20 PAGE 1 OF 2 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com Description These vibrating type bells are designed for use as fire or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4” (101mm) square electrical box for indoor use or on a model BBK-1 or HC-BB weatherproof backbox for outdoor applications. Weatherproof backbox model BBK- 1 or HC-BB, Stock No. 1500001. Notes 1. Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30° to 150°F (-34° to 66°C) 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. 3. ULC only applies to PDC-DC bells. Technical Specifications Dimensions 6” (150mm), 8” (200mm) and 10” (250mm) Enclosure Cover: Steel Finish: Red Powder Coat Base: non-corrosive composite material All parts have corrosion resistant finishes Model BBK-1 or HC-BB weatherproof backbox (optional) Voltages Available 24VAC 120VAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Environmental Limitations Indoor or outdoor use (See Note 1) -40° to 150°F (-40° to 66°C) (Outdoor use requires weatherproof backbox.) Termination AC Bells - 4 No. 18 AWG stranded wires DC Bells - 18 AWG stranded wire Service Use NFPA 13, 72, local AHJ *Specifications subject to change without notice. Features • Listed for indoor and outdoor use • Outdoor use requires BBK-1 or HC-BB weatherproof back box • Indoor use mounts directly to standard 4” box • Low current draw • High dB output • AC and DC models • DC models are motor driven, polarized, and have built in transient protection for supervised alarm circuits • Available in 6”, 8” and 10” sizes In outdoor or wet installations, bell must be mounted with weatherproof backbox, BBK-1 or HC-BB. Standard electrical boxes will not provide a weatherproof enclosure. If the bell and/or assembly is exposed to moisture, it may fail or create an electrical hazard. • Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. • Shock hazard. Disconnect power source before servicing. Serious injury or death could result. • Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. R * ULC on PDC-DC Only Size inches (mm) Voltage Model Number Stock Number Current (Max.) Typical dB at 10 ft. (3m) (2) Minimum dB at 10 ft. (3m) (1) 6 (150)12VDC PDC-6-12 1750500 200mA 96 76 8 (200)12VDC PDC-8-12 1750502 .200mA 96 77 10 (250)12VDC PDC-10-12 1750504 .200mA 96 78 6 (150)24VDC PDC-6-24 1750501 .20mA 95 77 8 (200)24VDC PDC-8-24 1750503 20mA 83 79 10 (250)24VDC PDC-10-24 1750505 20mA 85 80 6 (150)24VAC PBA246 1806024*.17A 91 78 8 (200)24VAC PBA248 1808024*.17A 94 77 10 (250)24VAC PBA2410 1810024*.17A 94 78 6 (150)120VAC PBA1206 1806120*.05A 92 83 8 (200)120VAC PBA1208 1808120*.05A 99 84 10 (250)120VAC PBA12010 1810120*.05A 99 86 All DC bells are polarized and have built-in transient protection. * Does not have ULC listing. *** ** FM on PBA-AC Only 5400777 - REV A • 12/20 PAGE 2 OF 2 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com BELLS PBA-AC & PDC-DC Wiring Rear View Installation Bell Dimension Inches (mm) Fig 1 Fig 3 2 11/16” (68 mm)DWG# 776-1 10” (250 mm)8” (200 mm)6” (150 mm) 5 3/4” (146 mm) 1 5/8” (41 mm) DWG# 776-2 3 3/8” (86 mm) 4 1/4” (108 mm) 3 3/8” (86 mm) 5” (127 mm) Weatherproof Backbox Dimensions Inches (mm) Fig 2 The bell shall be installed in accordance with NFPA 13, 72, or local AHJ. The top of the device shall be no less than 90” AFF and not less than 6” below the ceiling. 1. Remove the gong. 2. Connect wiring (see Fig. 3). 3. Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). 4. Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). 5. Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). MODEL BBK-1 OR HC-BBFailure to install striker down will prevent bell from ringing. NOTES: 1. OBSERVE POLARITY TO RING D.C. BELLS.2. RED WIRES POSITIVE (+).3. BLACK WIRES NEGATIVE (-).4. EOL RESISTOR IS SUPPLIED BY FIRE ALARM CONTROL PANEL. NOTES: 1. WHEN USING A.C. BELLS, TERMINATE EACH EXTRA WIRE SEPERATELY AFTER LAST BELL.2. END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS . NOTES: 1. OBSERVE POLARITY TO RING D.C. BELLS.2. RED WIRES POSITIVE (+).3. BLACK WIRES NEGATIVE (-).4. EOL RESISTOR IS SUPPLIED BY FIRE ALARM CONTROL PANEL. NOTES: 1. WHEN USING A.C. BELLS, TERMINATE EACH EXTRA WIRE SEPERATELY AFTER LAST BELL.2. END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS .