Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
90005 - FIRE ALARM SUBMITTAL
801 Valley Avenue N.W. Suite D, Puyallup, WA 98371 Phone: (253) 840-9900 | Fax: (800) 591-4382 REDHAHF901QP FIRE ALARM SYSTEM SUBMITTAL SITE ADDRESS: HARBOR FREIGHT 906 EAST YELM AVENUE YELM, WA 98597 PREPARED BY: Red Hawk Fire Protection 801 Valley Avenue NW Suite D Puyallup, WA 98371 RED HAWK FIRE PROTECTION JOB # 90005 SUBMITTAL INCLUDES: SCOPE OF WORK EQUIPMENT DATA SHEETS BATTERY AND VOLTAGE DROP CALCULATIONS CERTIFICATIONS 801 Valley Avenue N.W. Suite D, Puyallup, WA 98371 Phone: (253) 840-9900 | Fax: (800) 591-4382 REDHAHF901QP TABLE OF CONTENTS: TAB 1 ******************** SCOPE OF WORK TAB 2 ******************** FIRE ALARM CONTROL PANEL (EXISTING) TAB 3 ******************** BOOSTER POWER SUPPLY TAB 4 ******************** SMOKE DETECTORS TAB 5 ******************** PULL STATIONS TAB 6 ******************** NOTIFICATION DEVICES TAB 7 ******************** SYSTEM BATTERIES TAB 8 ******************** BATTERY AND VOLTAGE DROP CALCULATIONS TAB 9 ******************** CERTIFICATIONS 801 Valley Avenue N.W. Suite D, Puyallup, WA 98371 Phone: (253) 840-9900 | Fax: (800) 591-4382 REDHAHF901QP Tab 1 – Scope of Work 801 Valley Avenue N.W. Suite D, Puyallup, WA 98371 Phone: (253) 840-9900 | Fax: (800) 591-4382 REDHAHF901QP SCOPE OF WORK: The intended scope of work is to install additional fire alarm devices in the new Harbor Freight tenant improvement space. The existing fire alarm panel is a Silent Knight 5208 and is located in the adjacent space, Goodwill. Install new notification devices throughout the tenant improvement. Add pull stations at all egress doors (if not currently installed at these locations). 801 Valley Avenue N.W. Suite D, Puyallup, WA 98371 Phone: (253) 840-9900 | Fax: (800) 591-4382 REDHAHF901QP Tab 2 – Fire Alarm Control Panel (Existing) Features•10 zones, 8 Class B (Style B) and 2Class A (Style D) or Class B (StyleB) zones, expandable to 30 zones•Supervised zone expanders and I/Omodules can be mounted remotelyfrom the main control panel•Event History Buffer (150 events)with date/time stamp•All zones are compatible with 2- or4-wire detectors•8 selectable/programmable outputpatterns for notification appliancecircuits•Built-in Digital Alarm CommunicatorTransmitter (DACT)•4 Notification Appliance Circuits•4 programmable general purposerelays•Programmable smoke verification,pre-alarm delay, cross zoning andenhanced verification mode featuresthat can help minimize false alarms•Programmable from the built-incontrol panel touchpad, remoteannunciator, or Windows®SKSSdownloading software•Direct connect port for on-siteup/downloading with Windows®SKSS downloading software•Built-in walk test feature•Single or dual interlock waterreleasing capability•Plex door option combines a deadfront cabinet door with a clearwindow, limiting access to the panelwhile providing single buttonoperation of the reset and silencefunctions•Programmable AC trouble relay •Built-in synchronization forappliances from AMSECO®,Gentex®, Faraday, System Sensor®,and Wheelock®•Programmable date settings forDaylight Saving Time•Clock source setting options for 50Hz, 60 Hz, or internal (uses thepanel’s internal clock)SpecificationsOperating Voltage: 24 VDCPrimary AC: 120 Vrms @ 60Hz, 2ATotal DC Load:6 AmpCurrent Draw:Standby:140 mAAlarm:460 mAFlush Mounting Dimensions:Height:24.75” (62.9 cm)Width:14.5” (36.8 cm)Depth:3-7/16” (8.73 cm)with 5/8” protrudingOverall Dimensions:Height:26-3/8” (67 cm)Width:17-3/16” (43.66 cm)Total Depth:4” (10.16 cm)Operating Temp:32° to 120° F(0° to 49° C)Humidity:10 - 93% noncondensingOptional Accessories•SK-5235 LCD Remote Annunciator•SK-5217 10 Zone Expander(2 max. per system)•SK-5280 Status Display Module (8max. per system)•5220 Direct Connect Module•5824 Serial/Parallel Printer InterfaceModule•SKSS Downloading Software •Plex-2 Door Option•SK-SCK Seismic Compliance KitListings and Approvals•UL Listed•CSFM Listed•MEA approval 429-92-E Vol. XIII•OSHPD (CA) OSP-0065-10 Model 5208Fire Alarm Control Panel with Digital Communicator The SK-5208 is a microprocessor based control panel with built-in UL listed communicator designed forapplications requiring smoke detection, manual pull stations, and sprinkler supervision. It features an easy toread LCD display with programmable English readout and user friendly tactile keys. The basic unit offers 10zones of initiation and is expandable up to 30 zones for larger applications. The SK-5208 has a complete line ofsupervised accessories that provide remote annunciation, auxiliary control zone expansion. Ideal for new andretrofit applications, the SK-5208 delivers the performance to handle your installation. The Fire Alarm Control Designed to Grow with Your Systems Needs, Without The Growing Pains. SK-5208 FIRE ALARM CONTROL PANEL FIRE ALARM CONTROL PANEL Model 5208Fire Alarm Control Panel with Digital Communicator Engineering Specification The system shall contain a fire alarm control panel to supervise and operate heat and smoke detection devices,manual fire alarm devices, alarm notification devices and visual annunciators. The system shall also be capableof monitoring for sprinkler supervisory and water flow conditions. The system must have a built in UL listed firecommunicator that can be enabled/disabled as needed on a per job basis. In addition, the system will soundalarms locally for purpose of evacuation. MADE IN AMERICA FORM# 350318 Rev E© 2013 Honeywell International Inc. This document is not intended to be used for installation purposes. We try tokeep our product information up-to-date and accurate. We cannot cover allspecific applications or anticipate all requirements. All specifications aresubject to change without notice. For more information, contact Silent Knight12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103,Fax: (203) 484-7118. For Technical support, Please call 800-446-6444.www.silentknight.com 801 Valley Avenue N.W. Suite D, Puyallup, WA 98371 Phone: (253) 840-9900 | Fax: (800) 591-4382 REDHAHF901QP Tab 3 – Booster Power Supply SK-PS6 / SK-PS10 6 Amp and 10 Amp, 24 Volt Power Supplies The PS Series is a remote power supply line from Silent Knight and is a direct replacement for the 5495/5499. The SK-PS6 is a 6 amp and the SK-PS10 is a 10 amp, remote power supply with battery charger that may be connected to any 12 or 24 volt fire alarm control panel (FACP) or used as a standalone power supply. The PS Series provides 24 VDC power for NACs (notification appliance circuits) configured as either Class B or Class A (requires the ZNAC-PS option card) with multiple sync protocol options. The PS Series also provides auxiliary power, constant or resettable, suited for detectors, annunciators, door holders, and other fire alarm system peripherals. The PS Series cabinet can hold two 7 AH or 18 AH batteries and can charge up to 33 AH batteries in a separate cabinet. FEATURES AND BENEFITS • Up to five (6 amp model) or seven (10 amp model) independently-configurable, power- limited output circuits for: –Class B and/or Class A NACs –Class B and/or Class A resettable or non- resettable 24V auxiliary power –door holder power • Converts from Class B to Class A wiring without losing any outputs using the ZNAC- PS converter card (sold separately) • Optimal for powering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated power • Optional addressable control, monitor, and relay modules and power-supervision relay (EOLR-1) • Configurable for ANSI® Temporal 3 or Temporal 4 coded output • UL-Listed NAC synchronization using System Sensor®, Wheelock®, Gentex®, or AMSECO® appliances • Synchronization can be triggered from FACP NAC/remote sync outputs, cascaded power supply, or a control module, single or multi, which may be housed within the power supply cabinet • Ability to cascade up to four power supplies • Two (6 amp model) or three (10 amp model) fully-isolated input/control circuits which can be programmed to any output • Two Form C normally-closed trouble relays for AC Trouble and General Trouble • 6 or 10 amp full load output, respectively, with 3 A maximum/circuit • Individual NAC power and trouble LEDs for diagnostic efficiency • Trouble history mode for diagnostic support • Wide range end-of-line supervision value (normal: 2-27K ohms) • Selectable earth fault detection (enable or disable) • AC trouble report delay timer • Completely configurable via onboard DIP switches, no extra software required • Self-contained in compact, locking cabinet constructed of heavy gauge steel with a corrosion-resistant powder coat chip and scratch-resistant finish • Cabinet designed with ten double knockouts and a removable door for ease of installation and wiring • Includes integral battery charger capable of charging up to 33 AH batteries • Cabinet can house two 7 AH or 18 AH batteries • Battery charger may be disabled via DIP switch for applications requiring larger batteries and external battery charger • Removable terminal blocks accommodate up to 12 AWG (3.1mm2) wire • Works with any UL 864 FACP which utilizes an industry-standard reverse-polarity notification circuit The PS Series are independently configurable power supplies, allowing you to pair any input with any output, and feature LED diagnostics for troubleshooting. Page 2 of 3 — SK-61095:C • 3/10/2021 ORDERING INFORMATION SK-PS6: 6.0 A, 120 VAC remote charger power supply in a lockable, metal enclosure, red SK-PS10: 10.0 A, 120 VAC remote charger power supply in a lockable, metal enclosure, red ZNAC-PS: Optional Class A converter card, sold separately SK-CONTROL: Addressable Control Module for one Class B or Class A zone of supervised, polarized Notification Appliances. Notification Appliance Circuit option requires external 24 VDC to power notification appliances. SK-RELAY: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch SK-MONITOR: Addressable Monitor Module for one zone of normally open dry-contact initiating devices. Includes plastic cover plate and end-of-line resistor. Module may be configured for either a Class B or Class A SK-MONITOR-2: Dual Monitor Module. Same as SK-MONITOR except it provides two inputs for Class B wiring only SK-RELAYMON-2: Provides two monitored inputs and two Form-C relays. Functions in Class B wiring only SK-CONTROL-6: Six-circuit supervised control module SK-RELAY-6: Six Form-C relay control module EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire smoke detector power BAT-1270-BP: Battery, 12 volt, 7.0 AH, 5-pack (two required) BAT-12180-BP: Battery, 12 volt, 18AH, 2-pack BAT-12330: Battery, 12 volt, 33AH SEISKIT-MULTI-1: Seismic kit for the PS Series. Includes bracket and hardware for two 7AH or two 18AH batteries. SK-PS6 / SK-PS10 TECHNICAL SPECIFICATIONS SK-61095 | C | 03/21 ©2021 Honeywell International Inc. Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.silentknight.com Silent Knight® and System Sensor® are registered trademarks of Honeywell International, Inc. Wheelock® is a registered trademark of Cooper Technologies Company. Gentex® is a registered trademark of Gentex Corporation. AMSECO® is a registered trademark of Potter Electric Signal Company, LLC. ANSI® is a registered trademark of the American National Standards Institute, Inc. ©2021 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Country of origin: USA PRIMARY (AC) POWER SK-PS6: 120 VAC, 50/60 Hz, 5.0A maximum SK-PS10: 120VAC, 50/60 Hz, 6.2 A maximum Wire Size: #12-14 AWG with 600 V insulation COMMAND INPUT CIRCUIT Trigger Input Voltage: 9 to 32 VDC Trigger Current: 2.0 mA (16 - 32 V); Per Input: 1.0 mA (9 - 16 V) RELAY CIRCUITS Trouble Contact Rating: 4 A at 24 VDC OUTPUT CIRCUITS • 24 VDC filtered • SK-PS6: TB8-TB9 – 1A Regulated, 3A special applications; TB10-TB12 – 0.3A Regulated, 3A special applications • SK-PS10: TB8-TB11 – 1.5A Regulated, 3A special applications; TB12-TB14 – 0.3A Regulated, 3A special applications • 6.0 A (SK-PS6) or 10.0 (SK-PS10) maximum total continuous current for all outputs SECONDARY POWER (BATTERY) CHARGING CIRCUIT • Supports lead-acid batteries only • Float-charge voltage: 27.6 VDC • Maximum current charge: 1.5 A • Maximum battery capacity: 18 AH (inside cabinet) • Maximum battery charging capacity: 33 AH (external cabinet) PHYSICAL Dimensions: 20.0”H x 14.5”W x 3.5”D (cm: 50.8H x 36.83W x 8.9D) Weight: with two 7Ah batteries is 24 pounds (10.9 kg), with two 18 AH batteries is 39 pounds (17.7 kg) STANDARDS AND CODES The SK-PS complies with the following standards: NFPA 72: National Fire Alarm Code UL 864: Standard for Control Units for Fire Alarm Systems (NAC expander mode) UL 1481: Power Supplies for Fire Alarm Systems AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S3511 CSFM: 7315-0559:0522 FDNY Approved FM Approved 801 Valley Avenue N.W. Suite D, Puyallup, WA 98371 Phone: (253) 840-9900 | Fax: (800) 591-4382 REDHAHF901QP Tab 4 – Smoke Detectors Agency Listings Photoelectric Smoke Detectors System Sensor i3™ series smoke detectors represent significant advancement in conventional detection. The i3 family is founded on three principles: installation ease, intelligence, and instant inspection. Features Plug-in detector line, mounting base included• Large wire entry port• In-line terminals with SEMS screws• Mounts to octagonal and single-gang back boxes, 4-square back • boxes, or direct to ceiling Stop-Drop ’N Lock attachment to base• Removable detector cover and chamber• Built-in remote maintenance signaling• Drift compensation and smoothing algorithms• Simplified sensitivity measurement • Wide-angle, dual-color LED indication• Loop testing via EZ Walk feature• Built-in test switch• Installation ease. The i3 line redefines installation ease with its plug-in design. This allows an installer to pre-wire bases (included with heads). The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods as well as direct mounting with drywall anchors. To complete the installation, i3 heads plug into the base with a simple Stop-Drop ’N Lock™ action. Intelligence. i3 detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the i3 line to minimize nuisance alarms. 2-wire i3 detectors can generate a remote LED- indicated maintenance signal when connected to the 2W-MOD2 loop test/maintenance module or a panel equipped with the i3 protocol. The SENS-RDR, a wireless device, displays the sensitivityof i3 detectors in terms of percent-per-foot obscuration. Instant inspection. The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector’s condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol, the EZ Walk loop test feature is available on 2-wire i3 detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. 2093290-01-E7272-1653:1523011446S911 3180932 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2009 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. A05-0318-007 • 6/09 • #2169 Ordering Information Model Thermal Wiring Alarm Current 2W-B No 2-wire 130 mA max. limited by control panel 2WT-B Yes 2-wire 130 mA max. limited by control panel 4W-B No 4-wire 20 mA @ 12 V, 23 mA @ 24 V 4WT-B Yes 4-wire 20 mA @ 12 V, 23 mA @ 24 V Accessories 2W-MOD2 2-wire loop test / maintenance module RT Removal / replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 inch (16.76 cm) diameter Smoke Detector Specifications Architectural/Engineering Specifications Smoke detector shall be a System Sensor i3 Series model number_______, listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4WT-B) with thermal sensor rated at 135°F (57.2°C). The detector shall include a mounting base for mounting to 3½-inch and 4-inch octagonal, single-gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws. The detector shall allow pre-wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual- color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24 V non-polarized Minimum: 8.5 V Maximum: 35 V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2-wire: 50 µA maximum average; 4-wire: 50 µA maximum average Maximum Alarm Current 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12 V, 23 mA @ 24 V Peak Standby Current 2-wire: 100 µA; 4-wire: n/a Alarm Contact Ratings 2-wire: n/a; 4-wire: 0.5 A @ 30 V AC/DC Physical Specifications Dimensions (including base)5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 oz (178 g) Operating Temperature Range 2W-B and 4W-B: 32°F to 120°F (0°C to 49°C); 2WT-B and 4WT-B: 32°F to 100°F (0°C to 37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (57.2°C) fixed Freeze Trouble 2WT-B and 4WT-B only: 41°F (5°C) Sensitivity 2.5%/ft nominal Input Terminals 14 to 22 AWG Mounting 3½-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Modes Power-Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby)Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid 801 Valley Avenue N.W. Suite D, Puyallup, WA 98371 Phone: (253) 840-9900 | Fax: (800) 591-4382 REDHAHF901QP Tab 5 – Pull Stations DF-52004:A1 • 04/22/08 — Page 1 of 2 BG-12 Series Manual Fire Alarm Pull Stations Conventional Initiating Devices DF-52004:A1 • F-050 General The Fire·Lite BG-12 Series is a cost-effective, feature-packed series of non-coded manual fire alarm pull stations. It was designed to meet multiple applications with the installer and end-user in mind. The BG-12 Series features a variety of mod- els including single- and dual-action versions. The BG-12 Series provides Fire·Lite Alarm Control Panels (FACPs), as well as other manufacturers’ controls, with a man- ual alarm initiating input signal. Its innovative design, durable construction, and multiple mounting options make the BG-12 Series simple to install, maintain, and operate. Features • Aesthetically pleasing, highly visible design and color. • Attractive contoured shape and light textured finish. • Meets ADA 5 lb. maximum pull-force. • Meets UL 38, Standard for Manually Actuated Signaling Boxes. • Easily operated(single- or dual-action), yet designed to pre- vent false alarms when bumped, shaken, or jarred. • PUSH IN/PULL DOWN handle latches in the down position to clearly indicate the station has been operated. • The word “ACTIVATED” appears on top of the handle in bright yellow, further indicating operation of the station. • Operation handle features white arrows showing basic opera- tion direction for non-English-speaking persons. • Braille text included on finger-hold area of operation handle and across top of handle. • Multiple hex- and key-lock models available. • U.S. patented hex-lock needs only a quarter-turn to lock/ unlock. • Station can be opened for inspection and maintenance with- out initiating an alarm. • Product ID label viewable by simply opening the cover; label is made of a durable long-life material. • The words “NORMAL” and “ACTIVATED” are molded into the plastic adjacent to the alarm switch (located inside). • Four-position terminal strip molded into backplate. • Terminal strip includes Phillips combination-head captive 8/32 screws for easy connection to Initiating Device Circuit (IDC). • Terminal screws backed-out at factory and shipped ready to accept field wiring (up to 12 AWG/3.1 mm²). • Terminal numbers are molded into the backplate, eliminating the need for labels. • Switch contacts are normally open. • Can be surface-mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box. • Backplate is large enough to overlap a single-gang backbox cutout by 1/2" (1.27 cm). • Optional trim ring (BG12TR). • Spanish versions (FUEGO) available (BG-12LSP, BG-12LPSP). • Designed to replace the Fire·Lite legacy BG-10 Series. • Models packaged in attractive, clear plastic (PVC), clam- shell-style, Point-of-Purchase packages. Packaging includes a cutaway dust/paint cover in shape of pull station. Construction • Cover, backplate and operation handle are all molded of durable polycarbonate material. • Cover features white lettering and trim. • Red color matches System Sensor’s popular SpectrAlert® Advance horn/strobe series. Operation The BG-12 manual pull stations provide a textured finger-hold area that includes Braille text. In addition to PUSH IN and PULL DOWN text, there are arrows indicating how to operate the sta- tion, provided for non-English-speaking people. Pushing in and then pulling down on the handle activates the normally-open alarm switch. Once latched in the down position, the word “ACTIVATED” appears at the top in bright yellow, with a portion of the handle protruding at the bottom as a visible flag. Resetting the station is simple: insert the key, twist one quarter- turn, then open the station’s front cover, causing the spring- loaded operation handle to return to its original position. The alarm switch can then be reset to its normal (non-alarm) position manually (by hand) or by closing the station’s front cover, which automatically resets the switch.52004p4c.jpg Page 2 of 2 — DF-52004:A1 • 04/22/08 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Fire•Lite® Alarms, SpectrAlert® Advance, and System Sensor® are registered trademarks of Honeywell International Inc. ©2008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Made in the U.S. A. Specifications PHYSICAL SPECIFICATIONS: ELECTRICAL SPECIFICATIONS: Switch contact ratings: gold-plated; rating 0.25 A @ 30 VAC or VDC. ENGINEERING/ARCHITECTURAL SPECIFICATIONS Manual Fire Alarm Stations shall be non-code, with a key- or hex-operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key or hex. An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red colored LEXAN (or polycarbonate equivalent) with clearly visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Under- writers Laboratories listed. NOTE: *The words “FIRE/FUEGO” on the BG-12LSP shall appear on the front of the station in white letters, approximately 3/4" (1.905 cm) high. Agency Listings and Approvals The listings and approvals below apply to the BG-12 Series pull stations. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. •C(UL)US: S711 •FM Approved •CSFM: 7150-0075:184 •MEA: 67-02-E •Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. Product Line Information BG-12S: Single-action pull station with pigtail connections, hex lock. BG-12SL: Same as BG-12 with key lock. BG-12: Dual-action pull station with SPST N/O switch, screw terminal connections, hex lock. BG-12L: Same as BG-12 with key lock. BG-12LSP: Same as BG-12L with English/Spanish (FIRE/ FUEGO) labeling. BG-12LOB: Same as BG-12L with “outdoor use” listing. Includes outdoor listed backbox, and sealing gasket. BG-12LO: Same as BG-12L with “outdoor use” listing. Does not include backbox. BG-12LA: Same as BG-12L with auxiliary contacts. BG-12LPS: Dual-action pull station with pre-signal option. BG-12LPSP: Same as BG-12LPS with English/Spanish (FIRE/ FUEGO) labeling. SB-10: Surface-mount backbox, metal. SB-I/O: Surface-mount backbox, plastic. (Included with BG- 12LOB.) BG12TR: Optional trim ring for semi-flush mounting. 17003: Keys, set of two. (Included with key-lock pull stations.) 17007: Hex lock, 9/64”. (Included with hex-lock pull stations.) NOTE: For addressable BG-12LX models, see data sheet DF- 52013. pull station SB-I/O SB-10 Height 5.5 inches (13.97 cm) 5.601 inches (14.23 cm) 5.5 inches (13.97 cm) Width 4.121 inches (10.47 cm) 4.222 inches (10.72 cm) 4.121 inches (10.47 cm) Depth 1.39 inches (3.53 cm) 1.439 inches (3.66 cm) 1.375 inches (3.49 cm) 52004dim.tbl 801 Valley Avenue N.W. Suite D, Puyallup, WA 98371 Phone: (253) 840-9900 | Fax: (800) 591-4382 REDHAHF901QP Tab 6 – Notification Devices Features • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Listed for ceiling mounting only The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Agency Listings 7125-1653:0504 7135-1653:0503 S5512 S4011 FM approved except for ALERT models 3057383 AVDS868-02 • 12/01/2017 • Page 3 AVDS868-02 • 12/01/2017 • Page 2 L-Series Specifications Architect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 × 4 × 1½-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 × 4 × 17⁄8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11 ⁄16 × 4 11 ⁄16 × 2 1 ⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3)8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens)6.8" diameter × 2.5" high (173 mm diameter × 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions (SBBCRL, SBBCWL) 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS868-02 • 12/01/2017 • Page 3 Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 UL Current Draw Data Horn Strobe Tones and Sound Output Data UL Max. Horn Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC DC FWR Candela Range 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 UL Max. Current Draw (mA RMS), Ceiling Horn Strobe, Candela Range (15–177 cd) DC Input 8–17.5 Volts 16–33 Volts 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1K Temporal High 111 164 69 94 147 163 184 229 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 FWR Input 16–33 Volts 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2017 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS868-02 • 12/01/2017 L-Series Dimensions Model Description Ceiling Horn Strobes PC2RL 2-Wire, Horn Strobe, Red PC2WL 2-Wire, Horn Strobe, White PC4RL 4-Wire, Horn Strobe, Red PC4WL 4-Wire, Horn Strobe, White L-Series Ordering Information Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box Model Description Ceiling Strobes SCRL Strobe, Red SCWL Strobe, White SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White 6.83" diam. (173 mm) 2.47" (62.7 mm) 1.37" (34.8 mm)6.92" diam. (175.77 mm) 2.5" (64 mm) 2-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box A0531-01 A0545-00 A0546-00 A0494-01 For a ceiling-listed horn-only device, see AVDS865 “Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications”. 801 Valley Avenue N.W. Suite D, Puyallup, WA 98371 Phone: (253) 840-9900 | Fax: (800) 591-4382 REDHAHF901QP Tab 7 – System Batteries PS SERIESTERMINALS: (mm) DIMENSIONS: inch (mm)PERFORMANCE SPECIFICATIONS Nominal Voltage 12 volts (6 cells) Nominal Capacity 20-hr. (600mA to 10.50 volts) 10-hr. (1.14A to 10.50 volts) 5-hr. (2.04A to 10.20 volts) 1-hr. (8.82A to 9.60 volts) 12.00 AH 11.40 AH 10.20 AH 8.82 AH Approximate Weight 8.1 lbs. (3.68 kg) Internal Resistance (approx.) 13.0 milliohms Max Short-Duration Discharge Current (5 Sec.)180.0 amperes Shelf Life (% of nominal capacity at 68°F (20°C) 1 Month 3 Month 6 Month 92% 90% 80% Operating Temperature Range Charge Discharge 5°F (-15°C) to 104°F (40°C) 5°F (-15°C) to 122°F (50°C) Case ABS Plastic Power Sonic Chargers PSC-122000A-C PSC-122000-PC www.power-sonic.com To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website. © 2018. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners. All data subject to change without notice. E&O.E POWER-SONIC EMEA (EMEA – EUROPE, MIDDLE EAST AND AFRICA) Smitspol 4, 3861 RS Nijkerk, The Netherlands T NL: + 31 33 7410 700 T UK: + 44 1268 560 686 T FR: + 33 344 32 18 17 E: salesEMEA@power-sonic.com GLOBAL HEADQUARTERS (USA AND INTERNATIONAL EXCLUDING EMEA) Power-Sonic Corporation 365 Cabela Dr Suite 300, Reno, Nevada 89523 USA T: +1 619 661 2020 E: customer-service@power-sonic.com General Purpose Fire & SecurityEmergency Lighting L HT W H Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice. F2: L: 5.94 (151) W: 3.86 (98) H: 3.66 (93) HT: 3.86 (98) NB: L: 5.94 (151) W: 3.86 (98) H: 3.66 (93) HT: 4.09 (104) FEATURES •Absorbent Glass Mat (AGM) technology for superior performance •Valve regulated, maintenance free spill proof construction •Power/volume ratio yielding excellent energy density •Rugged vibration and impact resistant ABS case and cover •Gas recombination technology •5 year design life APPROVALS •Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certified •U.L. recognized •ISO9001:2015 – Quality management systems Medical F2: L: 5.94 (151) W: 3.86 (98) H: 3.66 (93) HT: 3.86 (98) NB: L: 5.94 (151) W: 3.86 (98) H: 3.66 (93) HT: 4.09 (104)Rev2: 08/20PS-12120 12V 12.0 AH @ 20-hr.12V 11.4 AH @ 10-hr. Rechargeable Sealed Lead Acid Battery PS – General Purpose Series Torque – Not Applicable 6.351.57.95 3.4 2.5 0.8F2: Quick disconnect tabs, 0.250" x 0.032" – Mate with AMP. INC FASTON “250” series NB: Tin plated brass post with ‘Nut & Bolt’ fasteners Torque: 2.0~3.0 Nxm 12mm 5mm5.3mm11mm2mm Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice. PS SERIESwww.power-sonic.com To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website. © 2018. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners. All data subject to change without notice. E&O.E POWER-SONIC EMEA (EMEA – EUROPE, MIDDLE EAST AND AFRICA) Smitspol 4, 3861 RS Nijkerk, The Netherlands T NL: + 31 33 7410 700 T UK: + 44 1268 560 686 T FR: + 33 344 32 18 17 E: salesEMEA@power-sonic.com GLOBAL HEADQUARTERS (USA AND INTERNATIONAL EXCLUDING EMEA) Power-Sonic Corporation 365 Cabela Dr Suite 300, Reno, Nevada 89523 USA T: +1 619 661 2020 E: customer-service@power-sonic.com SHELF LIFE & STORAGE LIFE CHARACTERISTICS IN STAND-BY USE Capacity Retention Ratio (%)Standing Period (Months) 100 80 60 40 00 2 4 6 8 10 12 14 16 18 20 40oC (104oF) 30oC (86oF)20oC (68oF) 5oC (41oF) Charging is not necessary unless 100% of capacity is required. Charging beforeuse is necessaryto help recoverfull capacity. 100 80 60 40 20 0 012345 Ambient Temperature 20˚C (68˚F) Float Charging Voltage 2.25 - 2.30 V/Cell Years SHELF LIFE & STORAGE LIFE CHARACTERISTICS IN STAND-BY USE Percentage of capacityavailable (Ah%)Capacity Retention Ratio (%)Standing Period (Months) 100 80 60 40 00 2 4 6 8 10 12 14 16 18 20 40oC (104oF) 30oC (86oF)20oC (68oF) 5oC (41oF) Charging is not necessary unless 100% of capacity is required. Charging beforeuse is necessaryto help recoverfull capacity. 100 80 60 40 20 0 012345 Ambient Temperature 20˚C (68˚F) Float Charging Voltage 2.25 - 2.30 V/Cell Years SHELF LIFE & STORAGE LIFE CHARACTERISTICS IN STAND-BY USE Percentage of capacityavailable (Ah%)CHARGING Cycle Applications: Apply constant voltage charge at 2.35v/c – 2.45v/c (14.1 – 14.7v for 12v Monobloc) at 20°C. Initial charging current should be set at less than 0.25C Amps. Switch to float charge to avoid overcharging. “Float” or “Stand-By” Service: Apply constant voltage charge of 2.25v/c – 2.30v/c (13.5 to 13.8 volts for 12v Monobloc at 20°C. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. Temperature Compensation: Charging Voltage for both Cyclic and Standby applications should be regulated in relation to ambient temperature. As temperature rises charging voltage should be reduced to prevent overcharge and increased as temperature falls to avoid undercharge. For further charging information including temperature compensation factors, see Power Sonic Technical Manual/ Power Sonic Charger specifications. CHARGERS Power Sonic offers a wide range of chargers suitable for batteries with a variety of capacities. Please refer to our website for more information on our switch mode and transformer type chargers. Please contact our technical department for advice if you have difficulty in locating a suitable charger. FURTHER INFORMATION Please refer to our website www.power-sonic.com for a complete range of useful downloads, such as product catalogs, material safety data sheets (MSDS), ISO certification, etc. APPLICATIONS •General purpose •Emergency lighting •Medical •Fire and security PS-12120 12V 12.0 AH @ 20-hr.12V 11.4 AH @ 10-hr. Rechargeable Sealed Lead Acid Battery PS – General Purpose Series Rev2: 08/20 801 Valley Avenue N.W. Suite D, Puyallup, WA 98371 Phone: (253) 840-9900 | Fax: (800) 591-4382 REDHAHF901QP Tab 8– BATTERY AND VOLTAGE DROP CALCULATIONS 24 90005 5 1.2 Date: 11/1/2021 10 Panel ID: Model:3.0 Amps Location: Volts: 24 VDC 9.0 Amps Wire AWG Ohms Per Length(ft) Actual Volts @ Standby Alarm & Type 1000 Ft. One-Way Ohms EOL PS-10 1 0.156 0.185 NAC #1 ####0.000 0.836 #14 Stranded 2.52 257 1.30 19.32 5.31% NAC #2 ####0.000 1.194 #14 Stranded 2.52 318 1.60 18.49 9.38% NAC #3 ####0.000 0.000 #12 Stranded 1.59 0.00 20.40 0.00% NAC #4 ####0.000 0.000 #12 Stranded 1.59 0.00 20.40 0.00% Aux ####0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% 0.156 2.215 24 0.083 (5 Mins) 3.744 0.185 Max Panel Current: Voltage Drop Warning Threshold % : SK-PS10 PS-10 Power Expander Max NAC Current: Alarm Time In Minutes / 60 Standby Hours: Alarm Mins: Derating Factor: Project Name: HARBOR FREIGHT Project ID: Prepared By: Standby Time In Hours Minimum Battery AmpHours Required 4.71 1.20Multiply By The Derating Factor Version 02.18.09 SPRINKLER RISER Total Standby AH Required PS-10 Power Expander Calculations %Drop PS-10 Pwr Module Ckt.# Circuit Name PS-10 Circuit 1 Total Alarm AH Required REDHAWK FIRE PROTECTION 3.93Total Combined AH Required Total Alarm Current (Amps)Total Standby Current (Amps) PS-10 Circuit 2 PS-10 Circuit 3 PS-10 Circuit 4 PS-10 Aux Power Out Current Draw Global Project Values: Wire resistances are based upon an ambient temperature of 72 degrees F. Because of the minimal difference between solid and stranded wire no differential was made. Configure Circuits Print Page Project Name:HARBOR FREIGHT Prepared By:REDHAWK FIRE PROTECTION Ckt. Number: NAC #1 Panel ID: Ckt. Name: PS-10 Circuit 1 3 Amps Standby Alarm Standby Alarm 2 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.132 # 4 System Sensor P2/PC2 Horn/Strobe (75cd) 0.000 0.176 0.000 0.704 # 0 System Sensor P2/PC2 Horn/Strobe (15cd) 0.000 0.091 0.000 0.000 # Unused 0.000 0.000 0.000 0.000 1 0.000 0.000 Totals 0.000 0.836 Ckt. Number: NAC #2 Panel ID: Ckt. Name: PS-10 Circuit 2 3 Amps Standby Alarm Standby Alarm 5 System Sensor P2/PC2 Horn/Strobe (75cd) 0.000 0.176 0.000 0.880 # 2 System Sensor P2/PC2 Horn/Strobe (15cd) 0.000 0.091 0.000 0.182 # 0 System Sensor P2/PC2 Horn/Strobe (30cd) 0.000 0.116 0.000 0.000 # 2 System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.132 # 0.000 0.000 Totals 0.000 1.194 Ckt. Number: NAC #3 Panel ID: Ckt. Name: PS-10 Circuit 3 3 Amps Standby Alarm Standby Alarm System Sensor P2/PC2 Horn/Strobe (135cd) 0.000 0.255 0.000 0.000 # System Sensor S/SC Strobe (15cd) 0.000 0.066 0.000 0.000 # Unused 0.000 0.000 0.000 0.000 1 Unused 0.000 0.000 0.000 0.000 1 0.000 0.000 Totals 0.000 0.000 Ckt. Number: NAC #4 Panel ID: Ckt. Name: PS-10 Circuit 4 3 Amps Standby Alarm Standby Alarm System Sensor P2/PC2 Horn/Strobe (135cd) 0.000 0.255 0.000 0.000 # System Sensor P2/PC2 Horn/Strobe (15cd) 0.000 0.091 0.000 0.000 # Unused 0.000 0.000 0.000 0.000 1 Unused 0.000 0.000 0.000 0.000 1 0.000 0.000 Totals 0.000 0.000 SK-PS10 Max Circuit Current: Qty Device Current Draw Each Current Draw Total Qty SK-PS10 Max Circuit Current: Qty Device Current Draw Each Current Draw Total Circuit Configuration Current Draw Each Current Draw TotalDevice SK-PS10 Max Circuit Current: 90005 11/1/2021 Project ID: Date: SK-PS10 Max Circuit Current: Qty Device Current Draw Each Current Draw Total Project Information Ckt. Number: Aux Panel ID: Ckt. Name: PS-10 Aux Power Out 3 Amps Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 1 Unused 0.000 0.000 0.000 0.000 1 Unused 0.000 0.000 0.000 0.000 1 Unused 0.000 0.000 0.000 0.000 1 0.000 0.000 Totals 0.000 0.000 SK-PS10 Max Circuit Current: Qty Device Current Draw Each Current Draw Total 801 Valley Avenue N.W. Suite D, Puyallup, WA 98371 Phone: (253) 840-9900 | Fax: (800) 591-4382 REDHAHF901QP Tab 9 – CERTIFICATIONS DEPARTMENT OF LABOR & INDUSTRIES Certified as provided by Law as. Electrician (EL06) - LIMITED ENERGY DILDIHC85OW1 0 Ea Date: 3/20/2075 Exp Date: 4/1112023 DILDINE, HEATHER C SPANAWAY WA 98387 wCOYNE This card certifies that HEATHER MATTIOI I has satisfactorily completed the cognitive and performance testing required by the standards of the COYNE FIRST AID, INC. Course of Instruction In: BASIC LIFE SUPPORT Jun 2, 2021 Jun 2, 2022 Date of Issue Date of Expiration NATIONAL INSTITUTE FOR CERTIFICATION IN ENGINEERING TECHNOLOGIES' Heather C Mattioli Fire Alain Systems Level III CERT NO. 147031 VALID THROUGH 0310@034 COYNE^ This card certifies that HEATHER MATTIOU has satisfactorily completed the cognitive and performance testing required by the standards of the COYNE FIRST AID INC. Course of Instruction in: BASK FIRST AID Jun 2, 2021 Jun 1, 2024 Date of Issue Date of Expiration qftw aCERTIFICATE OF TRAINING Heather Mattioli has successfully completed the safety training program Confined Spaces Training was completed on: 12/20/19 Authorized Signature's N NATIONAL INSTITUTE FOR CERTIFICATION IN ENGINEERING TECHNOLOGIES' Heather C Mattioli Fire Alain Systems Level III CERT NO. 147031 VALID THROUGH 0310@034 COYNE^ This card certifies that HEATHER MATTIOU has satisfactorily completed the cognitive and performance testing required by the standards of the COYNE FIRST AID INC. Course of Instruction in: BASK FIRST AID Jun 2, 2021 Jun 1, 2024 Date of Issue Date of Expiration qftw aCERTIFICATE OF TRAINING Heather Mattioli has successfully completed the safety training program Confined Spaces Training was completed on: 12/20/19 Authorized Signature's Heather C Mattioli Fire Alarm Systems Level III 147931 2024-08-01 JLrrKhYUUKUUN Seattle, Fire DEPARTMENT OF LABOR &IND- , CertifieC as MvIded b USTRIES u Electrician y Law as: (ELoe) - LIMITED ENERGY GORDOJM908KD EBDate:67i&XIo CORDON, JEFFREY M Date: ,122027 'ELM, WA 9&59].2931