Sketch 101117129R1
PSE GENERAL SPECIFICATIONS General - All work is to be completed per PSE Standards & Practices. Copies of all PSE Standards are available upon request. - Work sites shall be kept clear of debris and all construction materials, equipment and packing shall be removed daily. - Return all unused and removed poles, transformers and hardware to PSE, storeroom. All copper shall be coiled and returned the day it is removed from the poles. Remove all unused pins and insulators. - Return all Street lights, area lights and floodlights. - All fault indicators will be maintained in their current location on the 1/0 cables upon completion of the job. If it is noted to remove any of the indicators they shall be returned to local PSE first response department for re -issue. Preconstruction - Notify appropriate city, County or DOT authorities 48 to 72 hours, or as required by permitting agency, in advance of starting work in Right-of-way involving a Permit. - All system switching shall be approved by System Operations (426.8824662) a minimum of 48 hours in advance. - Notify customers of all outages 48 hours in advance. Work Drawings & Documents - Field design changes shall be approved by Project Manager or Engineer. - Mark all field changes, equipment ID numbers and Underground cable information in red on Foreman's copy of work sketch. - Return one Foreman's copy of work sketch to Project Manager at completion of job. - When permits are required, a copy shall be available on work site at all times. Safety - Refer to PSE standards 6275.3000 and 6275.6000 for system ground requirements. - Refer to PSE standards 6275.9050 for personal protective grounding requirements. - Refer to PSE standards 6275.9150 for vehicle grounding and barricading requirements. - Proper line clearances shall be taken at the beginning, and released at the end, of each work day, or as otherwise instructed by the System Operator. Traffic /Pedestrian control notes - Utilize flagging and other vehicle traffic control as necessary and in conformance with local traffic regulations. _ -The uniform code of traffic control shall be adhered to at all times.. -Provide signs, barricades, and traffic control in conformance with local permit regulations. -Provide route for pedestrians when working on or near sidewalks. -Maintain traffic flow as required by permitting agency. NOTE: Completely rebuild terminations. EXCEPTION: DO NOT REPLACE CUTOUTS UNLESS THEY ARE THE OLDER "BOX TYPE" OR 50 AMP "TRIP LINK" TYPE CUTOUT, REPLACE J -BOXES IF REQUIRED. UTILIZE FEED-THRU T.U:T.s AND REMOVE J -BOXES IF POSSIBLE. REPLACE ALL TRANSFORMER JUMPERS WITH NEW 1/0 JACKETED CABLE. UNDERGROUND CONSTRUCTION Additional notes to standards. -Erosion control must be placed before construction starts. Silt bags must be installed in downstream catch basins. Existing Utilities: Hand excavate (pothole) all marked utility crossings to verify exact location and depth at point of crossing. Protect underground utilities during excavation. Use hand excavation methods if necessary to avoid damage to existing utilities. Fabricate and install adequate temporary structures to support and protect underground utilities while exposed during construction. Maintain 6" minimum clearance at crossings between existing utilities and new duct installations. Transition trench or tunnel profile gradually as required at crossings. Maintain 24" minimum separation between new trench or tunnel and parallel existing utilities or as required by the permit agency. Excavation - Trenching outside of the Right-of-way shall be of sufficient depth to provide a minimum of 36" of cover for primary conductors and 24" of cover for secondary conductors. - Road crossings and all trenches within the Right -of --way shall be of sufficient depth to provide a minimum of 36" of cover for all conductors or as required by the permitting Agency. - No rocks larger than 8" shall be included in backfill. - Back fill in road crossings and within the Right-of-way shall be compacted to 95% density or as required by the permitting Agency. - Restore all excavated areas to original condition. Vaults & Hand holes - Refer to PSE standard 6775.0040 "Vault and Hand hole Installation" No Vaults shall be placed level and 2" above final grade in landscaped areas and flush with final grade when placed in hard surface areas. "A minimum 6" bed of 5/8" crushed rock shall be placed under all vaults. AN All conduit entrances shall be grouted. Conductors & Conduit Refer to PSE standard 6800.6000 "PVC Conduit Installation". - Unless splices are called for, or otherwise noted or approved, conduit risers shall be plumbed directly to road crossing conduits. - Install insulating caps on all unused primary bushings. - Civil crew to install Conduit plug on each end until new cable to be installed. - All "spare" conduits shall be capped at each end. Surface Restoration Restore ground surface to original contour and original condition or better. Restore asphalt and concrete in accordance with requirements of local permitting agency. Cold patch or plate trench when necessary. Leave area in its original state or better at the end of construction. OVERHEAD APPARATUS "When performing planned work on a pole with an existing transformer or device, the Service Provider will change out bolted connectors to pressed connectors". Use unit 1-3A to charge time. If you are working on a pole with the pole ground connected with a hot tap, replace it. If the transformer has split bolts on the secondary neutral or services, replace them. If the primary neutral is connected with a hot tap, replace it. If the transformer bank has a 2 -bolt connector on the neutral bus, replace it. ABANDONING PRIMARY CABLES PSE std. 6825.6200 In a Vault if the cable is in conduit, -Remove the cable Not in conduit or it cannot be pulled out, -Cut the cable off approximately one foot from the vault wall. Install a cap on the tail. -When practical, attach the old cable number to the cable stub. In a Minipad hand hole In conduit, =Remove the cable Not in conduit or it cannot be pulled out, -Cut the cable off as much as practical. install a cap on the tail. -When practical, attach the old cable number to the cable stub. -Stuff the tail into the bottom of the handhole. Be sure the new cables are not trapped by the old cables or the concentric neutrals. At Risers if the cable is In Conduit -Remove Cable Direct buried or it cannot be pulled out, -Cut off the cable at the top of the riser. Install a cap on the tail. and the pole will remain. When practical, attach the old cable number to the cable stub. DIRECT BURIED Direct buried or it cannot be pulled out, and the pole will be replaced DIRECT BURIED Direct buried or it cannot be pulled out, and the pole will be removed -Remove the riser. -Cut off old cable.just below grade. Re -fill ground back to existing grade. -Cut off the cable just below grade. NOTE: If the pole is to be replaced, remove the abandoned riser and elbow, and stand off brackets (unless they support other conduits). NOTE: If the riser is made of transite material, it shall be removed following procedures in standard 0100.5000, "Transite Pipe Removal and Disposal." •place and backfilled. (Transite is a mixture of asbestos and cement. itis nonmetallic, flame-retardant, and resistant to moisture, low temperature, and corrosive agents). For removal use an approved certified abatement contractor. Call the Environmental Services Department 24-hour pager (206-994-3186) to have a contractor dispatched. Procedure to Abandon Primary Cables: 1. Call the Systems Operator to request a clearance. 2. Follow the directions to ensure the cable is de -energized, apply proper tags as specified in Standard Practice 01 41011, "Switching and Clearances Handbook," and report back to the Systems Operator. 3. Obtain a clearance from the Systems Operator on the cable to be abandoned. 4. Cut the ends of the cable. 5. The cable number tag may be left on the abandoned cable. Y NOTE: The cable number shall not be reused. 6. Call the Systems Operator and release the clearance. 7. Remove all "Danger Do Not Operate" tags. 8. The System Operator will then close the 0# (Operations number). Existing System: Maintain existing electrical system in service until new system is complete, tested, and ready for service. Disable exWing system only to make cutovers and connections as directed by PSE System Operator. SCOPE OF WORK The general scope of this project is to remediate primary cables within the project area by the most economic means possible using replacement, or abandonment. The project involves replacing existing electrical cables in new conduit. Project type : Planned Project location : 1212 CRYSTAL CT NW YELM WA 98597 Number of Cables: 3 Cable Footage Estimated : 762' Cable Numbers Injected : 0 Cable Numbers Repaired : 0 Cable Numbers Abandoned : 0 Cable Numbers Replaced : 921609217,9218 Trench Footage Estimated : 762' There will be an advance notice provided by the contractortoo 24-hour advance notice of no parking in work areas. Access will be maintained to all residences and their driveways. When work is occurring directly in front of driveways, the contractor will work with the residence to manage access. Traffic Revisions Flagging crews will maintain one lane; flaggers will assist vehicles alternating through the roadway during work hours. For more information on the project 24-hour project information (888) 471-7339, (360) 825-5236 INDEX PAGE 1 -GENERAL NOTES PAGE 2 -SITE PLAN CABLE &CONDUIT DIAGRAM &EXISTING CABLE MAPPING EROSION & SEDIMENT CONTROL REQUIREMENTS EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE 0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL &ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. (LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION'' STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.)' Filter fabric skirt Secured with grate, Catch Basin Grate Collected Sedini Catch Bas(n Insert MID 9995728 EROSION CONTROL NOT TO SCALE —Overflow Filter fabric wails for dewatering sediment Trench and backfill requirements for primary electric line extension trenches - A 12"layer of sand, 5/8" minus or clean shading is required when excavated native material contains rocks up to 8" in diameter. A 3"layer of sand, 5/8" minus or clean shading is allowed when excavated native material contains rocks no larger than 8" In diameter. Excavated Dirt Pile ROADSIDE 12" Typical 24" Min — ► Final Grade i (ROW) 36" MIN Cover Backfill (PVT PROP) ' (No rocks over 8" diameter) 36" MIN 48" Max 12"Min Shading Clean Native Soil, Sand or 5/8" Minus doo,O_ _ 3" Bedding Clean Native Soil, Sand or 5/8" Minus Conduit FOREMAN TO CONTACT REGIONAL CONSTRUCTION MANAGER FOR COVER DEVIATIONS FROM THIS DETAIL PHOTOS AND DETAILED NOTES SHALL BE PROVIDED BY FOREMAN TRENCH DETAIL nlnr -rn Sr.AI 1= LEGEND ELECTRONIC MARKER Q SOLID BLADE DISCONNECT J ❑ UNDERGROUND COMBINATION J-BOX/XFMR ' FUSED DISCONNECT: 10T, 15T, 25T, 40T, 100T - INDICATES FUSE SIZE J D COMBINATION J-BOX/PADMOUNT XFMR I NORMAL OPEN (N.O.) J ■ NEW UNDERGROUND COMBINATION J-BOX/XFMR �1 --I WN WILL NOT PHASE (WN 10) J ♦ NEW COMBINATION J-BOXIPADMOUNT XFMR CD-- OVERHEAD TO UNDERGROUND CABLE TERM, TOTAL UNDERGROUND XFMR (T.U.T.) NEW OVERHEAD TO UNDERGROUND CABLE PAD MOUNTXFMR «— TERMINATION NEW UNDERGROUND XFMR O FAULT INDICATOR NEW PADMOUNT XFMR — �— CABLE SPLICE QJ UNDERGROUND J -BOX QM PRIMARY METERING QS UNDERGROUND SWITCH CABLE TERMINATION BUS (J -BOX) PULL VAULT___ ____ THREE PHASE WIRE/CABLE - 12.5 KV HANDHOLE_��__ SINGLE PHASE, ONE WIRE/CABLE - 7.2 KV CABLE TO REPLACE ABBREVIATIONS w— PROPERTY LINE P.E. =POLYETHYLENE RIGHT OF WAY X.F.M.R.=TRANSFORMER CENTERLINE, N.T.S. =NOT TO SCALE EASEMENT 1211 12"MIN 12" MIN MIN EXISTING - PAVEMENT / SIDEWALK 10111712981 NIA - .••.• 108110834 FUNCTION SPHALT PATCH, 2"MIN CONTACT PHONE NO DATE 2 MATCH EXISTING PROJECT MGR C.YLENNI 253.720-9700 719/19 1 09/24/19 N: RAFEEQ ll ENGR - POWER .ii VERTICAL SAW 253-548-4516 I< % CUT LINE DATE ' DESCRIPTION 48" MAX 36°MIN . ,.. CRUSHED SURFACING COUNTY THURSTON +s .; �-g MATERIAL COMPACT (ROW) 36" MIN _ I c, TO 95% MAX DENSITY, DRAWN BY M.POMEROY 253-234-6560 (PVT PROP) CHECKED BY 'MIN ", i ;di 1/4 SEC SE 18.17-02 OP MAP N/A .< PLAT MAP N/A APPROVED BY 12" Min Sand Shading or 5/8" Minus FOREMAN #1 U -MAP NO (POWER) 1702E072 j Conduit CIRCUIT NO I YEL-25 3" Sand Bedding or 5/8" Minus MAPPING POTELCO DESIGN AND QUALITY ASSURANCE ❑ This design complies with PSE DesignlEngineering Standards. Any/all variations have been pre-approved/documented by the appropriate PSE Representative, Signature Print Name Date EXCAVATION AND HARD RESTORATION DETAIL NOT TO SCALE VICINITY MAP • .,,; .... ANp�ERS rr AAGrtroR c' C AN 9 A 80 0057117 Q: :Cpl A0 06411 c0aA5i0Q iwas•. co :11• 3rd W: Q€ y AC ' O' 2: H' D' W' AY' J: 4• CARLA Cr:va B 30 V/EW ACRES � •oli Cid : WNo some 6 ~: �r co 0Ad : B0GR%VE �C A . �445 U �do : c�� cos:: Y553Q z ? @ I OT t 0 DWI, 444 � ti t • G b .:C Gaeta OR 75T t V• Sb 1; :30 c Y-1256 ti : 30 Ahe 0we . 0 IRAN 30: No X459 0*0 oil "id a B� Y-549 Y 10 0 :3N i.. — 36 IOOT 40T " �p..., PoWIN P Y-1287 65T i 0;....... — Y-694 CgNgL Rp C0� g4olr --1 •f---� A LM (� 6 876 Y1 4�T Y ' IryanMAP Wd MAPd *24 40T 005♦ 15T i �""C 25T Y-2095 Y-lQSat Y-588 E • Pop ••.....A :.....r o Y-645 D Q 5 ::o - BO IT Y 81863 QI Ago• 40T • alone*: 15T,. di Z owed A iyI Y-2098 ;��'s,B v, ,,0 y I,. CNO NAM Road S vI09698& 7 T B •B cosiee� 4:31 2S LR79TAL JA 535 YEL po ::3 q` •met 64 c v Y-3 AO 0T ae 2 5 ©cos2n3py...,. 1 r• 060601 SPRINGS 0T Cidr B,••,•,••„••,; Bic Y-523 409 ,.�-Y ��j YELto I30 -gr¢It '•... C. id •, •. •A :....... Y-2085 23; t•, . ^4Y2192 4 r Y—t0a3C 140T o Y 50 A •••„•Y534 ••dead••• Y115TC07440 I y 25T 10 Y1225 NO 40T I Y1111 Y1589 J 25 (1249 3 G • 65T �O 3L©Y10 4oT , Y1086 617 C _ _ .llw' 40T40T•Q �5T ;1b g1�(0 Y1451 Y2213 2Ad Y224 pP0 Y460 4oT :� 25� pp� Y1563 y No Y1447 JAI ; ��ti 30 25T ?r oVA E(ttt ,( Y1 30 Y21332 �h3, C 066 weaC B '40T �oii1� A 1L�P 70 r�uG�9 eons 0 25T Y1840 Y1238 tOT\� RP ,t s r� s 986Add Z Y1239 Y2190 Y203 YEL so 100T +C ssr Y182 Yl 240 65T Y1237 27 Y�14 ria?%Z 000600 Y930 Y11DOT Y1241 40T:B Y275 �Cn4 VA Y1063 OVERHEAD CIRCUIT: MAP # 1702E068. SCALE 6” = 1 MILE #1 #2 FOREMAN (CHECK BOX WHEN COMPLETED) PSE E ul ment LOCKEDISECURED & Work Area left In CLEAN/SAFE Condition, ❑ ❑ Grid, Cable, and Switch numbers INSTALLED & VERIFIED. ❑ ❑ Fleid Changes RED -LINED on As -built. ❑ ❑ Material VERIFIED di�end CHANGES noted on Paperwork. ❑ ❑ Total PRIMARY Cable noted on As -built ❑ ❑ any ID#'s RECORDED in correct location on As -built ❑ ❑ Indicate correct FUSE SIZE on As -built & VERIFY proper PHASE. ❑ ❑ Conecl QC Checl isl(s) reviewed. ❑ ❑ Deviations noted on the As-bullt and their reason. Ili ❑ ❑ I codify that the work performed meets PSE's standards and procedures end that all quality requirements are met. #1 Foreman's Signature #1 Print Nam Date C dr #2 Foreman's Signature #2 Print Nam Date4 dl PROJECT PHASE NOTIF# ORDER# SUPERIOR FAILED SILICONE REMOVAL O&M MAINTENENCE EXPENSE 1146335081 10111712981 NIA - .••.• 108110834 FUNCTION CONTACT PHONE NO DATE 2 CABLE REPLACEMENT Trench Method: BORE Approximate Trench Footage: 675' Abandon Cable Segments: d Replaced Cable Segments: Approximate New 10 pri. Cable Footage: 75' Approximate 2" Poly Conduit Footage: 715' Vaults 0 "Locates Required" as v I ' I I� ; ' a � 8i'rw roi im✓'; � i. , ,i I j f f i �a t 'I it N eaw o Gs �. (0 g e"m real s ho14 14 �� a" Contact Information PSE: PLANNER 22884 RYEN DR NW POULSBO, WA 98370 DOUG JONES 360-394-6636 For contacts below dial 1 -888 -CALL PSE (225-5773) MAKE NO CHANGES TO THIS JOB WITHOUT PRIOR APPROVAL Notify Customers and Service Area 48 NRS Prior To Planned Outages , g CALL(800)424.5555 2 BUSINESS DAYS BEFORE YOU DIG THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES -- �� "Flagging Required" es No No PERMIT CITY YELM 3 v I ' I I� ; ' a � 8i'rw roi im✓'; � i. , ,i I j f f i �a t 'I it N eaw o Gs �. (0 g e"m real s ho14 14 �� a" Contact Information PSE: PLANNER 22884 RYEN DR NW POULSBO, WA 98370 DOUG JONES 360-394-6636 For contacts below dial 1 -888 -CALL PSE (225-5773) MAKE NO CHANGES TO THIS JOB WITHOUT PRIOR APPROVAL Notify Customers and Service Area 48 NRS Prior To Planned Outages , g CALL(800)424.5555 2 BUSINESS DAYS BEFORE YOU DIG THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES -- �� "Flagging Required" es No REAL ESTATE/EASEMENT ,r REQ- PERMIT CITY YELM 3 N/A FUNCTION CONTACT PHONE NO DATE 2 N/A PROJECT MGR C.YLENNI 253.720-9700 719/19 1 09/24/19 N: RAFEEQ CHANGE TO BORE ENGR - POWER C.TOBIN 253-548-4516 7/9/19 REV# DATE BY DESCRIPTION ENGR-GAS N/A N/A N/A COUNTY THURSTON Emer Sect N/A Gas Wk Ctr N/A POWER WK CTR QSEPRE DRAWN BY M.POMEROY 253-234-6560 7/9/19 CHECKED BY 1/4 SEC SE 18.17-02 OP MAP N/A - PLAT MAP N/A APPROVED BY FOREMAN #1 U -MAP NO (POWER) 1702E072 OH CKT MAP 1702EO68 UG CKT MAP 1702EO71 CIRCUIT NO I YEL-25 FOREMAN #2 MAPPING - JOINT FACILITIES ARRANGEMENTS UTILITIES CONTACT PHONE# PUGET SOUND ENERGY DESIGNED BY Potelco, Inc. YEL-25 CRYSTAL CT CRP 2020 CABLE REMEDIATION PROGRAM 1212 NW CRYSTAL CT YELM WA 98597 INCIDENT N/A MAOP N/A Gas Order N/A Elect Order 10111712981 SCALE N/A PAGE 10172 SCALE: 1:50 EXISTING CABLE MAPPING SCALE:1:50 ' ABANDONED /REMOVE /REPLACED CABLE SCHEDULE CABLE NO. SAP EQUIP LOCATIONS CABLE (LF) EST EXISTING CABLE MFG. NAME EXISTING CABLE MFG. DATE ABANDONED CABLE LEFT IN PLACE ABANDON CIRCUITRY FROM TO 9216 10565717 301 V01 222 VAULT SIZE &COVER BP -2 YES NO 9217 10585729 V01 VO2 .263 BP -3 BORE PIT YES NO 9218 10585737 VO2 V03 277 BORE PIT ROW YES NO TOTAL CIRCUIT FEET 762' M.POMEROY PRIMARY CABLE &CONDUIT TABLE (FOREMAN TO COMPLETE) CRP09 301 559813 NX 147438 25T Y599 V01 559805 NX 147438 NX 559805 VO2 147460 Cp9216 CPJ9217 CRYSTAL CT NW 559835.197478 b9XVA 1II9tldOV C09218 Standoff Bracket NX 559803 V03 d 15' Min Length �\�cf )� 147481 Conduit Clamp 5' EXISTING UNDERGROUND MAP: # 1702E071 . SCALE: 1:100 PO1 25T Y599 a � � V01 Z vol � � 2-2" - L Q 2_2„ _ L Q (0 Z Q; � N -sig -�- 112.1 lbs 111.6 lbs -► 6.4 /bs 83.8/bs } �� CRYSTAL CT NW y � 4 U 12" L V03 EHY937 - Cf6 1-2" - L EHY938- CID 1-2" - L � EHY939-00 PRIMARY CABLE &CONDUIT DIAGRAM NOT TO SCALE VOLUME OF DISTURBANCE TABLE TYPE DESCRIPTION PROPERTY CLASSIFCATION SIZE (FT) REM CU YD (APPX) GRAVEL FILL CU YD (APPX) TYPE OF SURFACE REMARKS BP -1 BORE PIT ROW 2 X 8 t.8 1.8 HARD VAULT SIZE &COVER BP -2 BORE PIT ROW 2 X 8 1.8 1.8 � HARD MANUFACTURING INFORMATION BP -3 BORE PIT ROW 2 X 8 1.8 1.8 SOFT 559805 BP -4 BORE PIT ROW 2 X B 1.8 1.8 SOFT M.POMEROY BP -5 BORE PIT ROW 2 X 8 1.8 1.8 SOFT OP MAP � N/A BP -6 � BORE PIT ROW 2 X 8 1.8 1.8 SOFT VO2 OPEN TRENCH TRENCH ROW 1 X 40 4.4 4.4 SOFT 147460 TOTAL PVT PROP CU YDS (APPX) 0.0 0.0 25kVA PM XFMR HDPE TOTAL ROW CU YDS (APPX) 15.1 15.1 V03 11 TOTAL CU YDS (APPX) 15.1 15.1 - (ft) VAULT& EQUIPMENT TABLE LOCATION CONDUIT PRIMARY CABLE QTY OF LUBE PRIMARY N/A N/A FUNCTION GRID REMARKS TYPE &SIZE BUSHINGS TRANSFORMER N/A SITE NUMBER VAULT SIZE &COVER EQUIPMENT IN VAULT 7/9/19 ID NUMBERS REMARKS DESIGN ACTUAL CABLE NUMBERS MANUFACTURING INFORMATION For Feeder Cable Only FROM LB DC (COMPANY ID) LENGTH LENGTH 559805 EXISTING 25kVA PM XFMR REV SIZE LENGTH REPLACE ELBOWS &CONDUCTORS V01 M.POMEROY VAULT 12o/24ov EXISTING 2 - WIRE CREW TO INSTALL GRID NUMBERS 147438 OP MAP � N/A 559605 EXISTING 25kVA PM XFMR - 8 `!•a(p•/ FOREMAN #1 REPLACE ELBOWS &CONDUCTORS VO2 VAULT 120/240v EXISTING 2 - FOREMAN #2 WIRE CREW TO INSTALL GRID NUMBERS 147460 559803 EXISTING 25kVA PM XFMR HDPE SCH 80 90 REPLACE ELBOWS &CONDUCTORS V03 11 VAULT 1zo/zaov EXISTING 1 - (ft) WIRE CREW TO INSTALL GRID NUMBERS 147481 TOTALS: 5 - YEAR TAPE LOCATION CONDUIT PRIMARY CABLE QTY OF LUBE N/A N/A N/A FUNCTION (gal.) REMARKS DATE 2 N/A N/A DESIGN ACTUAL TYPE BENDS 7/9/19 PULL 09/24/19 DESIGN ACTUAL CABLE NUMBERS MANUFACTURING INFORMATION For Feeder Cable Only FROM TO SIZE QTY LENGTH LENGTH N/A N/A PULL REV SIZE LENGTH LENGTH DRAWN BY M.POMEROY Check applicable box 7/9/19 CHECKED BY 1/4 SEC SE 18.17.02 OP MAP � N/A PLAT MAP NIA APPROVED BY `gyp - 8 `!•a(p•/ FOREMAN #1 U -MAP NO (POWER) 1702E072 OH CKT MAP 1702E068 UG CKT MAP 1702E071 CIRCUIT NO YEL-25 FOREMAN #2 (in) (g) (ft) D8120 HDPE SCH 80 90 45 22 11 (lbs) (lbs) (ft) (ft) A B C MANUFACTURER COMPOUND YEAR TAPE CN #4/0 NEU DESIGN AS Gas Order N/A Elect Order 10111712981 SCALE N/A PAGE 2 OF 2 BUILT 301 V01 2 1 225 178.3 209.1 VO ALJKT 265 - - EHY937 07 V01 VO2 2 1 245 111.6 112.1 1/O ALJKT 255 - - EHY938 0.8 VO2 V03 2 1 245 83.9 96.4 1Io AL JKT 255 - - EHY939 0.8 TOTAL 2" 715' TOTAL 1?i 775' TOTAL LUBE 2.3 CIVIL CREW NOTE: ALL 2" - 90° BENDS MIN 48" RADIUS SCH-80 PVC ALL 2" - 45° BENDS SCH-80 PVC -ALL CONDUITS SHALL BE CAPPED AT EACH END UNTIL CABLE IS INTALLED =field Face Road Fact Quadrant Quadrant I Climbing Space Direction of Vehicular Traffic Climbing Space TOP VIEW CONDUIT RISER REPLACEMENT DETAIL @ 301 NOT TO SCALE. CONSTRUCTION NOTES 301 -CUT OFF CABLES AT TOP OF RISER -INSTALL A CAP ON THE TAIL -ATTACH OLD CABLE # TO CABLE STUB -REMOVE OLD C/O &TERM -INST 1O LB C/O TERM F:25T STD 6043,1000 (TSU1C1) -INST 1-2" L 'RISER ON STAND-OFF BRKTS STD 6042.1000 (RIS2CSS) -INST SW# Y599 STD 6300.0750 -INST SWITCHBOARD 12' ABOVE GROUND STD 6300.4000 CREW TO PROVIDE ALL PROPERTY OWNER'S THAT ARE IMPACTED BY PROJECT PRIOR NOTICE AND MAKE AN EFFORT TO WORK WITH PROPERTY OWNER'S TO MAINTAIN THEIR ACCESS TO THEIR PROPERTY, AS WELL AS, REDUCE THE IMPACT OF OUR WORK ON THEIR USE OF THEIR PROPERTY. FOREMAN NOTE: CALL (800) 424-5555 UTILITY NOTIFICATION CENTER 24/7 BEFORE BEGINNING ANY EXCAVATION PREVENTS DAMAGE TO UNDERGROUND FACILITIES, SERVICE INTERRUPTIONS & CIVIL CREW FOREMAN NOTE: MAINTAIN ON SITE, IN GOOD CONDITION, A COMPLETE FILE OF ALL WORK DRAWINGS. THESE DRAWINGS SHALL BE AVAILABLE AT ALL TIMES TO A PUGET SOUND ENERGY REPRESENTATIVE. CORRECTIONS AND CHANGES MADE DURING THE JOB SHALL BE RECORDED CONTINUOUSLY ON THESE DRAWINGS. FURNISH PUGET SOUND ENERGY A COMPLETE SET OF AS -BUILT PRINTS (FOREMAN'S COPIES) AT THE END OF THE JOB. WIRE CREW FOREMAN NOTE: ALL FAULT INDICATORS WILL BE MAINTAINED IN THEIR CURRENT LOCATION ON 1/0 CABLES AFTER NEW CABLE IS INSTALLED UNLESS OTHERWISE SPECIFIED. PLEASE RED -MARK ALL FAULT INDICATORS ON "CABLE DIAGRAM" FOR MAPPING. ®'' 0 �_ N ;ti REAL ESTATElEASEMENT REQ- PERMIT CITY YELM 3 N/A N/A N/A FUNCTION CONTACT PHONE NO DATE 2 N/A N/A N/A PROJECT MGR L.YLENNI 253-720-9700 7/9/19 1 09/24/19 N. RAFEEQ CHANGE TO BORE ENGR -POWER C.TOBIN 253-548-4516 7/9/19 REV# DATE BY DESCRIPTION ENGR -GAS N/A N/A N/A COUNTY THURSTON Emer Sect N/A Gas VMc Ctr N/A POWER WK CTR OSEPRE DRAWN BY M.POMEROY 253-234-6560 7/9/19 CHECKED BY 1/4 SEC SE 18.17.02 OP MAP � N/A PLAT MAP NIA APPROVED BY `gyp - 8 `!•a(p•/ FOREMAN #1 U -MAP NO (POWER) 1702E072 OH CKT MAP 1702E068 UG CKT MAP 1702E071 CIRCUIT NO YEL-25 FOREMAN #2 MAPPING JOINT FACILITIES ARRANGEMENTS UTILITIES CONTACT PHONE# PUGET YEL-25 CRYSTAL CT CRP 2020 SOUND ENERGY CABLE REMEDIATION PROGRAM 1212 NW CRYSTAL CT YELM WA 98597 DESIGNED BY Potelco, Ina INCIDENT wA MAOP N/A Gas Order N/A Elect Order 10111712981 SCALE N/A PAGE 2 OF 2 U to E 00 N rn 0 N INNI NU NWe -r ' ----- - - --- - - - u K �" 555920-147451 --_-_L_ �'t�{)-•-11__44, u5 N i l 55843614747-0 :/ 553335107192 I --'-"� 'r -.._._ 26kVA 1201240' Fill v - 10VA120240Y 1 dood 55 I 1_.21` CANAL RD NW k IS 40T �� 33 .... { y �)/ 550030147441 Y1685 _ _"-'-+..__` `~ �.. - 26kVA 1202409 8507 k1(/ .( .... .: i 5 59 03 414 754 5 &, " . 559832-10751 ;- PPII/'1'/ z a j fsaH7 9002 8605 _._------"-'fit 1105 SOABV566 1).y 15810 8003 I- i 16009 ad 1114 _ 15811 I'isI - 9008 q i y--...--_��--._-.-_ 554910147522 ''., :1 9011 --370VA 1202409""'' t 559WRIA4755 r ......,9;•(21,) :a` Ji.6hVA 130840 i)�l ., 1111-d 1 .-' 76812 16013 ; t , :.t .................-1111 ):1 k..,j.... 1111.. _.�-.---_---__-- FIR .-..-1--- .N,.F. 559910.147522 1516 -- adara.8013 6511 d 1 37,0VA 12012409 n 559914.14755 559904147441 16614 37AkVA 1201240 1fikVA 1201340 ..0 .5 15816 111, t '-- 1111...--. _.._ - 'l--' �E�H --_-- 9017 0 1\ 16did 906 \ 9 '\ ,. 59900120124 16817 ', -- J76hd 1102109 „\ Ck - -= - S ............. ............... 0 J _.._�. --'-- 550006447525 1 .. 1114 I 9F �' 559099447 ' )I to BOAR%0]e 559900.147538 18 2 37.6hVA 1201240v B. 0, . e 5 41 FF 55(88514/391 % 559005.4474t5 5728- fy.. � ......... 1 111 ... ........... ... .... ........ �---a-_ m 15710 15711 559877147415 _ 4 nr, ---- / 26kV0.120240v 76740 5'98X41474-00 ----\ - -__ ._l- 559063.147488 ibG44 Or1.. j3 .......................,.4.........,0,9 .. -- -550 1 167 26kVA 11D1240v / (/ 77-14749 15734 IF 'u' Y688 Os ..� 1111... {) '.. 124 SRD \ i .r YJ,.._- J 1 ,ij F 1111 127 ....y 118 118 / �\ - .•" y '•.•:,; ` N, �. I 1 Ora p2 556874197440 1+ ?. - � A,, 559077447415 009243 + 16kVA 11012409....Id...,, '.., G 1111. •�'t'. .^„ - "'"�- / 116 rn .. 26kVA 1202909 559801147488 ..-.� 1 VIk1W ORNW ` 40T 116 .,, ..� - @ 26kVA 1202/09 1 , 11'41 :, c,� 407 Y636 550675147466 W ... Y2098 120 / / \ 59814441520 AOADW327L. - __M1 -�_ 1111 .�.,^ \ - 76XVA/201240v jlk'1' ). / 116 a.... 6506,3.147400 :...... 114 A0ADWM ., 1111. ^\ - 11 ............ ........... 1111 k' - 1. .. - ❑ 7shvquB24av )j" \, / .. _^......�,0 ............... .1111.. .. 1111.. ......... .._ 1111.. .......... __ 1111... ......... 170 i" `� DOVNK 0.; a7, 4104 �. VIEW DR Hill �... '4411, � �.)�'� 11 tv, 1111.. .. ....... - / 15773 ... .. _ r 16711 •�....-` ' �/ '•• �• 559971'IM1757/ VIEWD RNW / 15651 -----_..__- . �• CRP09'' 90AARise 559875.147466 559074.147520 15717`,, i _ 76kVA 12012d0v - 550840447435 ..,, % ,' 'I'd -_...-1144- - MVA120240V __ __ ---- . -- I CRP09 1111... 1 -"-' ."'-.-_� 113 VIEWDRNW 'I•pc j1p5D49B9D) 132 .� 1 7 15615 t`:t i 121 ilii114 DOMKI57 r 16409 , (0503091) I'v �, CRP09 iIk r- ......Od 1311 ; 1111. , i5-10447) i SOAAR758 1111 CRP09 .....:'. --- _- 7: 111 III. , ,P 117 CRP09 .........p - % 1111... ..III 6 ' - - 1 i 122 15G03 -.:' _�- i` / -_- i r-- 0 - I l.j 558851147139 550840.141158 122 ;} -- > tEkVA /30/2109 76X1'0 1202009 11 ... IN 131 ,I t ,f•J 112 114} 119 l I _ 11 �a ;% I k 4 ` ' 121 105 I ;' 2 n 4, , 1 G _ ----- of v MVA 1202409 669645-14751 5 '' ` 559848447458 -' f30 ;' t - ,. - _;_, _'"-_.__.-._--.- -- �_-.-.___60kVA 1201240 t ....__... 76kVA 12012409 _�,_, fMMM3 - I - In 1309 _.,.4 - 4 j Q a In 0) r 117 b P 3 _ A ) .-^--.., `.5., '� ° 5 0 76kVA 12012409 I i 1° 1f0 125 z A 559045.147515 `- "• 559033447399 559?37147431 ) 113 '\1 116 60WA 1201240v 26kVA 13011409 y_... 16kVA 1202409 I ♦Itc �_--j / /' 10: \\`•'----- _- .16641 16666 16734 15730 __-"-�n_(J 16742 16746 550631147430 t l} �. -- ---- - 115 15730 559628�147JOB .nc „/, , � i 129 � � �' �0� jl VIEW OI'E NAR 6854 37.6kVA 12012409 CR "• ([ ...-adad 000 - -.'C ` ,7 vi lU 24 ,"."d 127 29825 w7b'7G -�---- _---___._ _ F IF "edV' /:J ._....: ....18688.' - 'Nfrad,., < .. -' _ 60kVA 420124011 $G 59X-8747491 C (.. ._...... 1111. - --_ --, ._ ... ..........' U 8 ../ /// .. ,_ 5580 01475 Irl - 559828.147409 120 / pll+a.-.. ..109 0> / ... -""' ,,• 60kVA 120240 `.., J1.6kVA 17012109 CRP09 - VIEW OR NW / ................ . 1111. f, 91STWAYSE �' / 111 :' y .•j 113 COrwu00 i60kVA 559025-047476 .__. 125 107 106 1201240V 5559830.14753O60kVA 559622-1417,130 a.; 559813147438---1 __-F __26kVA /201140W 12012409 - __-,_--, 25T / - - 91STWAYSEuY609 1211T0 59010747432 t 1 y :)FINNt 1212 �' --1111.. Is" a 1111... 1109 /20ftl 4 1111199 ;' ..1105147400 �n1212 �' ._805147438 1210 ....A1201240IF .."Na 1�' 1213 1214555005147420 2EhVF 11o2gOv _ ... �/ ... ^, 1210 559545.147971 Nd }._.. ,.i. .. 1 ........... tQ .16, m (101079128),, 2, N %IN 1 CRYSTAL CT NAF ;( - 1207 550802-1-17518 � C 09216 C09218 � . t Fad,'"� \ ,Y _- 1 �t) 15704 16716 _- i -- - -' 6it 1t NIF1212409 _ C09217 55970514740u 6710 \, 376kVA012024ov ,'` k \\ / 16 TFIURST00l CI'FINFIN Ct / 37.5kVA 120124011 : ', % 92 -I : d" vi 'A a INuto, ' 1111... '.] CRYSTALCTNW OV . n.... _ 1111. ,- .... 1.114. . 4 15701 . o _ .. •114.1•., . . e� ,.` 11 11 . 1111 ' - ! 1111 �,,,•. 559105 147411 1201 - �\ 1106 RP14 079-0 W7634 C \ / ? 5a 558790147508 i •.,- ..• • ` ^'••-••• "" �31 ••.... !•.' ..;,• : 15720 1201 1207 1204 \ - it --� 10108 55,3 37.6kVA 17012-009 (1 ) "" 559785147408 37,5XVA/201240v TN9RSTON CT fl _.. -- 1205 w :., 0025407 J7.6kVA 120134011 AOAOL462 147392 i W -. __ _ _ V p J7 1 .,Is.r, 02ND Cf SE '550701-X7422-- _ Liz add ;(.j '559767 W7437 �+ - -- - d b V c - )J1 31kkVA 120129011 26kVA 12013409 A025483 CR I Ac 111297 559794.147534 C L.. /'-- .0 1209 - 1208 PJB254Be ,(bikt(�30555) )v MIR 12013409 \\%;' _ / 1107 15722 a 1113 1106 1206 �I w / 37 - J .it ' , \�•`-- .,. t 1114 92NOCTSE 9791,147422 556X110 /y j 13705 } �" / -_ --.._ _-__- __- J7. V 12020 in - 9136 / 1116 1116 1A f11112 vi j vl' (( 1110 7 � \} `t' .p 483 w z V. 15721 -__ ,4. .--_ D(p, /L 1113 \, I. 1114 1116 ins < 15711 16726 \ �' ,^5072 w7.mf, ?'. / 1112 U ! 0240 '-1 16720 '6 t ,0 / "-41 tE2 4 d 1117 k t ,' i 55078& 47431 ' . .......... ..._ ° 5597-00 X/437 t t. 550164 147474 7 la ABANQ fi0NVA 1201240 �J... .-� 1•� I I lad .. 1111 . .. ........ ............. 1111. . ............. ..........- _1111 ayjk" ._. ..... ..4141..... ld..11.11..... ......1� ............. .....�' ( . / .• '-••�"��- .....4.... �. 267 •• / I Y623 I `376hVA 120240V PID2550o {" . '11 1111.. 4414 __l 1 _/ 55976E 147453 t, i - .-.. h........ ___ '1 k 107 00 Q a fi _ - - j!h I.idid i-? _68701 d /, -_ / 8026601 CO25503 0022829 21: .' 1111'.. v) .. ........ ................. .. ... ........ }�7 .. 6 0kVA 12012409 1111... ... - I 2 .. ............. m 659771-147300 I) \kk WAY bE .� •,�'c OIW OUEfJJSVIEV4 CI _ ......... ........ .. ' ' . ^�+.`....� I ' ' 55977(.147Si6 1111 ` NV RHOTON CI �I 92ND I ' __ A BAND i { al.50kVA 0025404 IAD254B3 / 1201 AOAGH3 C -All -_ ._ 2 - d' 55977014750 D 025900 ^ t4 060 5) 559772.147531 559765147422 I-), ••• .. 111......1. ... ...... - _---"'-o„ '-' kl ._'.`-;-"'-"_--'' _-_ -0 376UVA 12012108 -_-- JAD22922. 558784.147480 to �O%aLd5359 1 ❑ 37.6X110 110 2 9 011 ... (]. 1111..-.. 26kVA12024BV / rt 1141.. / -- _ ,:%( 3.06124) / `... `, i 60kVA 120240v /a0ADL458 147392. 14.,.49 a1 `- /Jj.... .,. �'a m 559771.147390 SE NW CUEENSVIEWCT RROTON CT N B244v? y, 5n a• ,,'4, 7111 92NOWAY � SEi, 1108 fill r` v% o CO26405 EIN/ 559770447508 16715 .. 1110 F(' 1109 559765.147422 c 37.6kVA 1202409 � 1102 1106 1107 1109 26kVA 120240V 645 16701 16707 16711 15729 6- 1 1110 7107 1108 392 0 1240VFit - NIk% FOREMAN MAP: U MAP # 1702EO72 / UG MAP # 1702EO71. SCALE: 1 E4 = 100'