Bar Cinco 0708KNIGHT FIRE PROTECTION, INC. 9702 LATHROP INDUSTRIAL DRIVE SW OLYMPIA, WA 98512-9188 360-786-8606 FAx 360-786-8722 CONTRACTOR'S LICENSE NO. # KNIGHFP044LK "ON GUARD 24 HOURS A DAY" TO: City of Yelm P.O. Box 479 Yelm, WA 98597 TRANSMITTAL DATE: October 27, 2008 JOB NO. ATTENTION: Building Official REFERENCE: Semi- Annual Suppression System Testing 7/30 COPIES DATE NO, DESCRIPTION 1 7/30 1 Chinese Wok 1 7/30 1 Bar Cinco 1 7/30 1 Yelm Senior Center 1 9/16 1 Puerta Vallarta THESE ARE TRANSMITTED FOR YOUR USE. REMARKS: COPY TO FILES SIGNED Am IF ENCLOSURES ARE NOT AS DESCRIBED, PLEASE NOTIFY US AT ONCE. RECClVED 2 8 20081 �:��,'' A KNIGHT FIRE PROTECTION, INC. 9702 LATHROP INDUSTRIAL DRIVE SW OLYMPIA, WA 98512-9188 (360) 786-8606 FAX 786-8722 "ON GUARD LICENSE NO. KNIGHFP044LK 24 HOURS A DAY" YL_Z r-11 Authority Having Jurisdiction T TECH I TECH 2 SEMI-ANNUAL CONFIDENCE TESTING RANGE HOOD SYSTEMS FACILITY r INSPECTION DATE ADDRESS ANNUAL SEMI-ANNUAL ,..CITY STAT_ E ZIP PHONE TIME ^ AM I PM OWNS ANAL EIS LAST HYDRO DATE HYDRO TEST DUE SIX YEAR MAINTENANCE SYSTEM MANUFACTURER 280 350 360 450 500 GAS ELECTRIC 2 MODEL HOOD/DUCT FRYER BROILER GRILL BURNERS HOT TOP OTHER YES NO NIA 1. Is system connected to building alarm or otherwise monitored? 2. Is cylinder pressure gauge and/or weight at acceptable levels?_ 3. Are all safety tamper seals and devices intact? 4. Are there any visible signs that system has been fired or tampered with? 5. Check hazards against nozzle layout?_ 6. Are all nozzles positioned and angled properly? ;- 7. All protective blow off caps or nozzle covers have been cleaned and/or replaced? >< 8. Checked action on self closing caps?_ 9. Tested system actuation with terminal link for proper operation? 10. Tested system actuation with manual pull stations for proper operation? 11. All manual actuators are unobstructed and path of egress? 54 12. Tested gas valve and cable actuation for proper operation? 44 13. Tested gas valve and from mounts and inspect? K 14. Tested micro switch actuation and/or manual reset for proper operation? 15. Verified all co6king appliances are dperatidimi? ` ' 16. Removed all cylinders from mounts and inspect? (Note any added maintenance needed: 17. Inspect all chemical agents for contamination? 18. Fuse links have been cleaned and/or replaced to the current year? �! 19. Is the hood and duct free from grease accumulation?_ 20. Checked exhaust fan operation and proper air flow? >e 21. Current service tag on the system and pull station?_ 22. All new tamper seals and devices are intact? 23. Proper hand portable] extinguishers are properly serviced and certified? Problems Found: �/Je 7'�57C On this date, the above system was tested and inspected in accordance with procedures of the applicable editions of NFPA standards and the manufacturer's O&M manual. This system was operated according to these procedures with results indicated above. WRITE -CUSTOMER -- YELLOW -KNIGHT FIRE PINK --AUTHORITY HAVING JURISDICTION GOLD TKNIGHTFIRE C �1� SERVICaECWCIAN CUSTOMER'S AUTHORIZED AGENT "QUALITY IS REMEMBERED... LONG AFTER PRICE I5 FORGOTTEN!" OCT 2 8 7008