Judylyn Manzano Stamped PlansJudylyn ManzanoDRAWN BY:DATE:07/01/2022EMSDESIGNSOLGEN POWER5100 ELM RD,PASCO, WA 99301P: 509-931-16631PAGE #PV 1ABCDEFGH12345
54321CUSTOMDRAWING SCALE:GENERAL NOTES1.PRIOR TO THE COMMENCEMENT OF ANYWORK, THE CONTRACTOR SHALL NOTIFYTHE DESIGNER OF ANY DISCREPANCIESWITH THE DESIGN IN ANY CAPACITY.ESPECIALLY RECOMMENDATIONS, CODES,OR REGULATIONS & RULES OF THEAUTHORITY HAVING JURISDICTION, WHICHSUPERSEDED THE NEC.2.ALL DIMENSIONS TO BE VERIFIED BYCONTRACTOR PRIOR TO COMMENCEMENTOF WORK.3.CONTRACTOR IS RESPONSIBLE FOR ALLSAFETY PRECAUTIONS, OSHAREQUIREMENTS ETC. FOR THE SITE,INCLUDING EXISTING SITE HAZARDS.4.SYSTEM IS GRID INTERACTIVE/INTERTIEDVIA A UL LISTED POWER-CONDITIONINGINVERTER.5.SYSTEM HAS NO ENERGY STORAGE OFANY KIND, OR UPS.6.ALL SOLAR MOUNTING FRAMEWORK TOBE GROUNDED.7.FOLLOW MANUFACTURERS SUGGESTEDINSTALLATION PRACTICES AND WIRINGSPECIFICATIONS.8.ALL WORK TO BE IN COMPLIANCE WITHTHE INTERNATIONAL BUILDING CODES.(IBC)9.ALL ELECTRICAL WORK TO BE INCOMPLIANCE WITH THE NATIONALELECTRIC CODE (NEC).ELECTRICAL NOTES1.WHERE ALL TERMINALS OF THEDISCONNECTING MEANS MAY BEENERGIZED IN THE OPEN POSITION, ASIGN WILL BE PROVIDED WARNING OFTHE HAZARDS. (PER ART. 690.17)2.EACH UNGROUNDED CONDUCTOR OFTHE MULTIWIRE BRANCH CIRCUIT WILLBE IDENTIFIED BY PHASE AND SYSTEM.(PER ART. 210.5)3.A NATIONALLY RECOGNIZED TESTINGLABORATORY SHALL LIST ALLEQUIPMENT IN COMPLIANCE WITHARTICLE 110.3.4.ALL WIRES SHALL BE PROVIDED WITHSTRAIN RELIEF AT ALL ENTRY POINTSINTO BOXES AS REQUIRED BY UL LISTING5.MODULE FRAMES SHALL BE GROUNDEDAT THE UL-LISTED LOCATION PROVIDEDBY THE MANUFACTURER USINGUL-LISTED GROUNDING HARDWARE.6.MODULE FRAMES, RAIL, AND POSTSSHALL BE BONDED WITH EQUIPMENTGROUND CONDUCTORS AND GROUNDEDAT THE MAIN ELECTRICAL PANEL.7.THE DC GROUNDING ELECTRODECONDUCTOR SHALL BE SIZEDACCORDING TO ARTICLE 250.166B &690.47.AERIAL VIEWRESIDENCE PHOTOSHEET INDEXPV 1 COVER PAGEPV 2 SITE PLANPV 3 ELECTRICAL DIAGRAMPV 6 PLACARDCONFIDENTIAL - THE INFORMATION CONTAINEDIN THIS PACKET AND SUBSEQUENT CUTSHEETSSHALL NOT BE USED FOR THE BENEFIT OFANYONE OUTSIDE SOLGEN POWER. NEITHERSHALL IT BE DISCLOSED TO OTHERS OUTSIDETHE RECIPIENT'S ORGANIZATION, EXCEPT INCONNECTION WITH THE SALE AND USE OF THERESPECTIVE EQUIPMENT, WITHOUT WRITTENCONSENT FROM SOLGEN POWER.CUT SHEETS ATTACHEDPV 4 CHIKO MOUNTINGPV 5 MOUNTING DIAGRAM15343 92nd Ave SE. 98957 Yelm WA 98597STRUCTURAL ONLY1/6/2022
NEWSCIRCUIT 1SOLAR OFFSET1'-6"ROOF AREA: 2,499 Ft2PV AREA: 191 Ft2ROOF %: 7.64 %INDEX:NUMBER OF MODULES:10MODULE TYPE:INVERTER:MODULESUTILITY METERMAIN SERVICEZNSHINEZXM6-NH120-360MHoymiles Series23COMBINER BOX41SYSTEM SIZE DC:3.60kWSYSTEM SIZE AC:3.00kWAC DISCONNECT52" x 4"TRUSS SPACING:TRUSS SIZE:24" O.C.DRAWN BY:DATE:07/01/2022EMSABCDEFGH12345
54321DESIGN1PAGE #PV 215/128" = 1'-0"DRAWING SCALE:SOLGEN POWER5100 ELM RD,PASCO, WA 99301P: 509-931-1663CONFIDENTIAL - THE INFORMATION CONTAINEDIN THIS PACKET AND SUBSEQUENT CUTSHEETSSHALL NOT BE USED FOR THE BENEFIT OFANYONE OUTSIDE SOLGEN POWER. NEITHERSHALL IT BE DISCLOSED TO OTHERS OUTSIDETHE RECIPIENT'S ORGANIZATION, EXCEPT INCONNECTION WITH THE SALE AND USE OF THERESPECTIVE EQUIPMENT, WITHOUT WRITTENCONSENT FROM SOLGEN POWER.Judylyn Manzano115343 92nd Ave SE. 98957 Yelm WA 98597COMP. SHINGLEWAC 51-54A-1204.2.1 IFC2018EXCEPTION 52345STRUCTURAL ONLY1/6/2022
(2)8 AWG(1)8 AWG EGC(2)8 AWG(1)8 AWG EGCMUTILITY METER (E)TO UTILITYGRID (E)200AMAIN SERVICEDISCONNECT (E)EXISTINGWIREMAIN SERVICE PANEL (E)(2)8 AWG(1)8 AWG EGC20A LOAD-SIDESOLAR OCPD(Opposite end of the main disconnecton the busbar - NEC 705.12(B)(3)1210CIRCUIT #1 - 10 ZNSHINE ZXM6-NH120-360MMODULESWITH HOYMILES HM-300N MICRO INVERTERS(2)12 AWG(1)8 AWG EGC20A OCPD
NEW SOLAR
DRAWN BY:DATE:07/01/2022EMSABCDEFGH12345
54321DESIGN1PAGE #PV 3NOT TO SCALEDRAWING SCALE:SOLGEN POWER5100 ELM RD,PASCO, WA 99301P: 509-931-1663CONFIDENTIAL - THE INFORMATION CONTAINEDIN THIS PACKET AND SUBSEQUENT CUTSHEETSSHALL NOT BE USED FOR THE BENEFIT OFANYONE OUTSIDE SOLGEN POWER. NEITHERSHALL IT BE DISCLOSED TO OTHERS OUTSIDETHE RECIPIENT'S ORGANIZATION, EXCEPT INCONNECTION WITH THE SALE AND USE OF THERESPECTIVE EQUIPMENT, WITHOUT WRITTENCONSENT FROM SOLGEN POWER.1Judylyn Manzano15343 92nd Ave SE. 98957 Yelm WA 98597COMBINER BOX PANEL SIZE CALCSCIRCUIT #NUMBER OFMODULESNUMBER OFMICROINVERTERSNOMINAL OUTPUTCURRENT IN AMPSTOTAL125TOTALAMPSBREAKER SIZECIRCUIT 11010x1.23=12.30x1.25=15.38=20AMAX AC OPERATING CURRENT CALCS# OF MICROINVERTERSMAX OUTPUT CURRENTMAX AC OPERATING CURRENT10x1.23=12.30ALOAD CALCS - TOTAL AMPS AVAILABLEBUS RATING120%TOTALMAIN BREAKERX=-=MAX BREAKER SIZE200A1.2240200A40ABREAKER SIZE CALCSMAX AC OPERATING CURRENT125%TOTALBREAKER SIZE12.30Ax1.25x15.38A=20A234NOTES:1.200A UTILITY METER GLOBE ONLY. (EXISTING)2.200A LOAD CENTER. (EXISTING)3.30A RATED NON-FUSED LOCKABLE AC DISCONNECT. (NEW)4.125A RATED COMBINER PANEL. (NEW)ALL CONDUIT SIZES ARE MINIMUM SIZESALL WIRE SIZES ARE FOR COPPER WIRE
7# RailL FEETFLASHINGMount to Existing RaftersDRAWN BY:DATE:07/01/2022EMSDESIGN1PAGE #PV 4ABCDEFGH12345
54321STRUCTURAL NOTES:1.TOTAL WEIGHT (MODULE & RAIL): 460 LBS2.RAIL WEIGHT: 41 LBS3.MODULE WEIGHT: 419 LBS4.DISTRIBUTED WEIGHT: 2.41 PSFSOLGEN POWER5100 ELM RD,PASCO, WA 99301P: 509-931-1663CONFIDENTIAL - THE INFORMATION CONTAINEDIN THIS PACKET AND SUBSEQUENT CUTSHEETSSHALL NOT BE USED FOR THE BENEFIT OFANYONE OUTSIDE SOLGEN POWER. NEITHERSHALL IT BE DISCLOSED TO OTHERS OUTSIDETHE RECIPIENT'S ORGANIZATION, EXCEPT INCONNECTION WITH THE SALE AND USE OF THERESPECTIVE EQUIPMENT, WITHOUT WRITTENCONSENT FROM SOLGEN POWER.5'9"3'5"5'9"0.67"13.8'D4'Mid ClampEnd Clamp4'4'14.24'Grounding Lug6"1.4"ROOFINGSOLAR PANELJudylyn Manzano15343 92nd Ave SE. 98957 Yelm WA 98597STRUCTURAL ONLY1/6/2022
67'13'-1"DRAWN BY:DATE:07/01/2022EMSABCDEFGH12345
54321DESIGN1PAGE #PV 51/8" = 1'-0"DRAWING SCALE:STRUCTURAL NOTES:1.48" MAX SPAN OF RAIL TO DISTRIBUTE WEIGHTOVER SUPPORT OF TRUSSES2.MOUNTING FEET ARE IN APPROXIMATE LOCATION.3.MOUNTING FEET SHOULD BE STAGGERED ASSHOWN IN DIAGRAM2MOUNTING DIAGRAM1MOUNTING DIAGRAMSCALE: NOT TO SCALESOLGEN POWER5100 ELM RD,PASCO, WA 99301P: 509-931-1663CONFIDENTIAL - THE INFORMATION CONTAINEDIN THIS PACKET AND SUBSEQUENT CUTSHEETSSHALL NOT BE USED FOR THE BENEFIT OFANYONE OUTSIDE SOLGEN POWER. NEITHERSHALL IT BE DISCLOSED TO OTHERS OUTSIDETHE RECIPIENT'S ORGANIZATION, EXCEPT INCONNECTION WITH THE SALE AND USE OF THERESPECTIVE EQUIPMENT, WITHOUT WRITTENCONSENT FROM SOLGEN POWER.MOUNTING FEETPV MODULECHIKO #7 RAILJudylyn ManzanoROOF 1TILT:23°AZIMUTH:180°15343 92nd Ave SE. 98957 Yelm WA 98597STRUCTURAL ONLY1/6/2022
NEWSDRAWN BY:DATE:07/01/2022EMSDESIGN1PAGE #PV 6ABCDEFGH12345
54321SOLGEN POWER5100 ELM RD,PASCO, WA 99301P: 509-931-1663CONFIDENTIAL - THE INFORMATION CONTAINEDIN THIS PACKET AND SUBSEQUENT CUTSHEETSSHALL NOT BE USED FOR THE BENEFIT OFANYONE OUTSIDE SOLGEN POWER. NEITHERSHALL IT BE DISCLOSED TO OTHERS OUTSIDETHE RECIPIENT'S ORGANIZATION, EXCEPT INCONNECTION WITH THE SALE AND USE OF THERESPECTIVE EQUIPMENT, WITHOUT WRITTENCONSENT FROM SOLGEN POWER.CAUTIONPOWER TO THIS BUILDING IS SUPPLIED FROM THEFOLLOWING SOURCES WITH DISCONNECTSLOCATED AS SHOWN:6"x6"15343 92nd Ave SE. 98957 Yelm WA 98597SOLAR PV ARRAY WITHMICROINVERTERSROOF MOUNTEDJudylyn Manzano15343 92nd Ave SE. 98957 Yelm WA 98597UTILITY METERMAIN SERVICE PANELAC DISCONNECT