Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Landscape Plans 031920
(12) Sho in (112) Blue Fescue (15) Midwinter Fire Dogwood— (29) Blue Star Juniper (4) Vine Mapl (18) Concorde Barberr u� iA (38) Kinnikinnick— (3) Shore Pine Columnar Hornbe (27) Kinnikinnick— (1) Amanogawa Cherry— (27) Kinnikinnic 344) Kinnikinnick (23) Jackman`s Potentilla 26) Dwarf Mugo Pine -(2) Vine Maple ° 7 % 0 ° PICNIC TABLE - TYP. HYDROSEED. LAWN °'•.:. ` ° •• DECOMPOSED GRANITE ALUMINUM EDGING - SEE NOTES .. .. . . . . . . . . , r .. ... ' . . v�. aa' 4rl d :.. >... '''''''''... '.'.'.'.'.'.'............... :.:.:'.:.' FiY©FCSED."LaN .. ............. .... / ........... ...... � 'ua:.- : rig ms=s • a�:'' ::� .: ............'n' .. . DECOMPOSED GRANITE . . •...... • I ( ..... w ...... / ( • • HORSESHOES PIT o I. 4 ° LU o / °d ................ 0.....'. o.'.'.'.'. Ir Y �a �f2D •Rli'••D'•: •RD�• � RD a ALUMINUM EDGING SEE NOTES' LL . : ... Hl'QRO•StED '.LAWN 46 Kinnikinnick ° :(•1.)::.4i:n'ikirlrri.�k ( ) (35) Kinnikin ick .. HYDROSEED - -. �. -r - ='' - �•' - LAWN ° ° o o 0 0 o 0 co� - - - a / HYDROSEED . .. . . LAWN.. ° : 1 (1) Amanogawa Cherry (12) Dwarf Mugo Pine (20) Concorde Barberry � ' 12 Jackman`s Potentilla 1 (4) Columnar Hornbeam Al 2) Vine Maple PLANT SCHEDULE TREES COMMON NAME CONT CAL SIZE of Landscape Architect or Owner. QTY Acer circinatum Vine Maple Cont. Multi -stem 6` HT. MIN. 10 ol Carpinus betulus `Fastigiata` Co umnar crnbeam B & B 2"Cal z W call -outs, and installing plantings per the landscape plan. Chamaecyparis nootkatensis `Pendula` Weeping Alaska Cedar Cont. u) 6` HT. MIN. for field conditions at the specified spacing. 5 Fagus sylvatica `Dawyck Purple` Dawyck Purple Beech B & B 2"Cal planting with Alaska Fish Fertilizer solution. ^ P, 4 Picea omorika Serbian Spruce B & B gram tablets distributed as follows: All trees: 4-21 gram 6` HT. MIN. .�� PND 4 Pinus contorta `Contorta` Shore Pine Cont. N • 6` HT. MIN. �N 15 Prunus serrulata `Amann awa` Amanogawa Cherry B & B 2"Cal CY per 1000 SF) of "Medium Grind" hem/fir bark mulch as top dressing. SHRUBS COMMON NAME SIZE SIZE Architect or Owner. NORTH QTY Berberis thunbergii `Concorde` Concorde Barberry 2 gal SCALE: 1" = 10'-0" 62 Cornus sericea `Midwinter Fire` Midwinter Fire Dogwood 3 gal 30 Festuca glauca `Beyond Blue` Blue Fescue 1 gal 124 Juniperus squamata `Blue Star` Blue Star Juniper 2 gal 34 Myrica californica Pacific Wax Myrtle 5 gal 10 Pinus mugo `Pumilio` Dwarf Mugo Pine 2 gal 79 Potentilla fruticosa `Jackmanii` Jackman`s Potentilla 2 gal 61 Thuja occidentalis `Smaragd` Emerald Green Arborvitae B & B 4-5 ft. ht. 12 GROUND COVERS COMMON NAME CONT SPACING QTY Arctostaphylos uva-ursi Kinnikinnick 4" pot 18" o.c. 776 12) Emerald Green Arborvitae II 7YI 7Yr 7YI 7Yr 7YI 7Yr 7Yr 7YwIIIaa � (2) Dawyck Purple Beech 3) Concorde Barberry (4) Concorde Barbe 6) Blue Fescue 4) Jackman`s Potentilla 8) Dwarf Mugo Pine 2) Blue Star Juniper RD •� fj r r.� % 7/Jt 7Yr ,fYI 7C•7 �.� r r.0 � �� itntz 5Q��7l- 1ktk6._Z 2 •....... JWA -WAAI (6) Blue Fescu (21) Dwarf Mugo Pin (10) Jackman`s Potentill (3) Blue Star Junipe V, FAI &W 0 UJIV Am Iffili k Am jo LANDSCAPE SHEET NOTES 1. Refer to details for additional information. 2. Chemically kill and remove from site all existing weeds and vegetation not shown to remain on plans. 3. Topsoil 3.1. Distribute 4" depth (12 CY per 1000 s.f.) imported topsoil mix (approved by the Landscape Architect) in all landscape areas and at depths indicated for crowning and berming of landscape areas, and backfill of retaining walls (if required). Topsoil mix shall be equal to: - "Lacey 3 -Way" as available from Walrath Trucking, (253) 472-1252 3.1. All landscape planting areas shall receive topsoil mix, whether indicated on plans or not, so that finish grades of all shrub beds shall be 2" below tops of adjacent curbs and pavement, and lawn areas shall be 1h" below tops of adjacent curbs and pavement. 3.2. Fine grade all landscape beds prior to planting operations. 4. Aluminum Edging 4.1. Aluminum edging shall be Y$" thick, 4" wide black anodized aluminum edging: - "Permaloc Cleanline" or approved equal. 4.2. Top of edging shall be installed at Y4" above finish grade. R .. a 4 ....... ... PICNIC TABLE - TYP. a ..... a ...... . . . . . d DECOMPOSED GRANITE CONCRETE PAD ....... ALUMINUM EDGING - SEE NOTES ° 0 0 0 (DOU • I 0 7 0 i o / / / I ' ........ r' : =' RD • Fid Rp'. 'fi f7D: ' R6% �. R�• a DCC0MPO*SED*.'.•- PICNIC TABLE - TYP. GIANI•TE • • • • • • • ALUMINUM EDGING -SEE NOTES : I YDR-GSEE-D -LAWN ... - - 0 0 0 0 0 ...)(0 eo CO x(12) Jackman`s Potentilla (2) Dawyck Purple Beech 17) Concorde Barberry ' � (2) Vine Maple —(12) Dwarf Mugo Pine 22) Kinnikinnick 5. Recreation Areas 5.1. Per YMC 18.56 Recreation/Open Space, 10% of gross site area is dedicated to recreation/open space. Areas dedicated to fulfill this requirement are all the decomposed granite areas (including, picnic tables, ping pong table and horseshoe pit). 5.2. The areas mentioned above fulfill the requirements as follows. - Gross area: 30,005 s.f. - 10% of gross area: 3,001 s.f. - Area dedicated per plan: 3,090 s.f. 6. Decomposed Granite 6.1. Decomposed granite areas shall be constructed on a layer of 4" of %" minus gravel base plate compacted, and top dressed with 2" decomposed granite or approved equal, also plate compacted to form a firm walking surface. 7. Concrete Pad for Ping Pong Table 7.1. Concrete pad for ping pong table shall be installed per outdoor ping pong table manufacturer's specifications. Minimum size 12' x 20'. 8. Picnic Table 8.1. Picnic tables shall be: "U -Line 8' Rectangular Picnic Table, H-2129BL" or approved equal. 9. Horseshoe Pit 9.1. Bidder designed & built horseshoe pit per standard regulations. HYDROSEED LAWN (46) Kinnikinnick 1) Amanogawa Cherry 30) Kinnikinnick QUALITY IN THE COMMUNITY 5) Weeping Alaska Cedar 10) Pacific Wax Myrtle 4) Serbian Spruce 18) Kinnikinnick 15) Midwinter Fire Dogwood I 15'-0" Dense Sight Barrier 18) Kinnikinnick 18) Kinnikinnick 18) Kinnikinnick HOUSI SHED 10. Plants r.0 00 10.1. No plant substitutions shall be permitted without prior approval 0 rn I of Landscape Architect or Owner. 10.2. All plants shall conform to the latest edition of the American m � o 'acD Standard for Nursery Stock. 10.3. Plant quantities are shown for reference only. Contractor is IWI responsible for verifying all quantities in list with actual plan z W call -outs, and installing plantings per the landscape plan. v1a m Groundcover and shrub quantities shall be adjusted as required u) wU for field conditions at the specified spacing. 10.4. All plants shall be thoroughly watered immediately after m" I w � planting with Alaska Fish Fertilizer solution. ^ P, 10.5. Fertilizer tablets for all plants shall be Agriform (20-10-5) 21 SHEET NUMBER gram tablets distributed as follows: All trees: 4-21 gram OF WASH .�� PND tablets; All shrubs (except 1 gals): 3-21 gram tablets; All 1 gallons: 1-21 gram tablet; Set tablets directly next to rootball. N • 11. Mulch �N EXP. Scq/'E 11.1. All shrub and ground cover beds shall receive a 2" depth (6 CY per 1000 SF) of "Medium Grind" hem/fir bark mulch as top dressing. 12. All work shall be performed to the satisfaction of the Landscape Architect or Owner. NORTH 0 11111111 10 20 SCALE: 1" = 10'-0" DATE REVISIONS 09/20/19 - RK 03/19/20 - RK 1 ULIEN I r.0 00 z 00 0 0 rn I zw „ J m � o 'acD Q z o xLd¢ IWI z W p O v1a m Q u) wU 0o 0 co Q m" I w � ^ P, M O SHEET NUMBER OF WASH .�� PND KOUy�tiC 2 O N • do �N EXP. Scq/'E ARO DATE REVISIONS 09/20/19 - RK 03/19/20 - RK 1 ULIEN I SHEET TITLE z 0 zw „ J m v Q z Q IWI Q zw W 0 Q z Q u) �z Q J J SHEET TITLE I OF I 0 zw „ J z� Q 0 U W U� �z Q Q J zQ_ Q v SHEET NUMBER I OF I W U 2" SL. 2" SL. 1—Y4" MAINLINE rE I 10 POINT OF CONNECTION AT NEW b/8" IRRIGATION METER. STATIC WATER PRESSURE APPROX. 50 PSI PER YELM PUBLIC WORKS. 1—Y4" MAINLINE 11 7712� 13 7,77, _ <1 ,. .:':': ':':':':' . ..... i...... ..... •d 6» S ° dQ 4' SL. yv 1 a v 2m I• I'.'............' UJ ...... . • . • .•......•.•,•,• .........................LJJ 2" SL: t f— ° Di Ct °. a . ...' : I :' :' ..............:.:.: . .'............... .................. "RRD �R %I" 5 --- — 1-Y4" MAINLINE/ 3 2 1 ve? RD RD U L 2 SL. 2,> SL. ° 2" SL. d d • ° ° Q, d d a 3 <: VALVE CHART VALVE I GPM I SIZE TYPE 1 <10 1" DRIP 2 10.7 1 " SPRAY 3 9.9 1 " SPRAY 4 11.1 1 " SPRAY 5 9.5 1 " SPRAY 6 11.1 1" SPRAY 7 10.5 1 " SPRAY 8 <10 1 " DRIP 9 9.5 1 " SPRAY 10 7.8 1 " SPRAY 11 <10 1" DRIP 12 6.3 1 " SPRAY 13 7.4 1 " SPRAY 14 <10 1" DRIP 15 <10 1" DRIP 16 <10 1 " DRIP 17 8.7 1 " SPRAY 18 7.1 1 " SPRAY 19 8.2 1 " SPRAY 20 8.2 1 1 " SPRAY 21 <10 1 " DRIP CLASS 200 PVC PIPE SLEEVES, INSTALL @ 24" DEPTH NOT SHOWN #18 -AWG MULTI -CONDUCTOR IRRIGATION CONTROL CABLE, PE JACKETED WITH PVC INNER INSULATION WITH RIP CORD, 600V RATING J 11TWAI &I V We' As M1 I RRI GA TION N 0 TES 1. Contractor to meet all local codes & ordinances. 2. Irrigation plan is diagrammatic. Field adjust to reflect actual field conditions. All piping, laterals, and wire to be located in bed or lawn areas where appropriate. 3. Pipe sizes are to remain constant between pipe size call—outs. 4. Locate all mainlines within the project limits. 5. Verify controller location with general contractor/Owner. 6. General contractor to provide 110V power to the controller. 7. General contractor to provide conduit from controller to the landscape. 8. See irrigation details for additional information. 9. Landscape contractor to coordinate & install sleeving with General Contractor. 10. The Property Owner is responsible for maintaining all plants in a healthy growing condition for the life of the project. 11. Landscape contractor shall provide as many lateral to drip connections as is necessary to provide a functional system and adequate water delivery to plants. See manufacturer guidelines for more information. 12. All lateral lines in drip zones shall be 1" dia. class 200 PVC pipe unless otherwise noted on plan or if flow exceeds 15 GPM. . .............................. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.' ° °d d . ''.'.'.'.'.'.'.'.'.'.'.'.'.'...'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'. �i . . . . . . . . . . . . . .a 2" SL: 0 / . .....................RD :.. :'...: ° ....................... �.'. ...................... d....................... :. d... .... .................... �.:... . d ° 2" SL. ° d' n A A �l L ,ei.V 21 4" SL: EQUIPMENT LIST SYMBOL I MFR. CATALOG NO. DESCRIPTION 1� I Note: - All lateral lines shall be 1" dia. unless otherwise noted on plan. - Irrigation controller shall be located in utility/mechanical room of one of the apartment buildings. coordinate location with general contractor. general contractor shall provide 110V power to controller and conduit to nearest landscape area. QUALITY IN THE COMMUNITY I NORTH 0 10 20 SCALE: 1" = 10'-0" co00 CD -t- z LATERAL TO DRIP CONNECTION - SEE IRRIGATION NOTE #11 FOR MORE INFORMATION. RAINBIRD XFD & XB -XX -PC XF SERIES Y2" BLANK DRIP TUBING WITH XB XERI-BUG DRIP EMITTERS (0.5, 1 OR 2 GPH). RAINBIRD 1804-8Q H F 4" POP-UP SPRAY BODY W 8' 90', 180° OR 360° ARC NOZZLE ❑ RAINBIRD 1804-10Q H F 4" POP-UP SPRAY BODY W 10' 90', 180° OR 360° ARC NOZZLE 0 RAINBIRD 1804-12Q H F 4" POP-UP SPRAY BODY W/ 12' 90% 180° OR 360° ARC NOZZLE O RAINBIRD 1804-15Q H F 4" POP-UP SPRAY BODY W 15' 90', 180° OR 360° ARC NOZZLE A RAINBIRD 1804-8VAN 4" POP-UP SPRAY BODY W 8' VAR. ADJ. ARC NOZZLE T RAINBIRD 1804-15SST 4" POP-UP SPRAY BODY W/ SIDE STRIP NOZZLE 7 r RAINBIRD 1804-15RCS LCS 4" POP-UP SPRAY BODY W RIGHT- & LEFT -CORNER STRIP NOZZLE = I� ►/ FEBCO 850 1" 1 " DOUBLE CHECK VALVE BACKFLOW PREVENTOR 8 SPEARS 2622 -XXX PVC BALL VALVE MATCH LINE SIZE ro RAINBIRD 3RC QUICK COUPLER VALVE - - ANGLE VALVE FOR MANUAL DRAIN OHUNTER 10 ICZ-101 1" DRIP REMOTE CONTROL VALVE KIT HUNTER PGV-100 1" REMOTE CONTROL VALVE NOT SHOWN RAINBIRD ESP4ME3 4 STATION BASE IRRIGATION CONTROLLER - SEE NOTE BELOW NOT SHOWN RAINBIRD ESPSM6 6 STATION EXPANSION MODULE FOR CONTROLLER (3 NEEDED) ------------- PRESSURE MAINLINE, SCH. 40 PVC PIPE, INSTALL @ 18" DEPTH 24" UNDER PAVED AREAS LATERAL LINES, 1" CLASS 200 PVC PIPE, INSTALL @ 12" DEPTH 24" UNDER PAVED AREAS) CLASS 200 PVC PIPE SLEEVES, INSTALL @ 24" DEPTH NOT SHOWN #18 -AWG MULTI -CONDUCTOR IRRIGATION CONTROL CABLE, PE JACKETED WITH PVC INNER INSULATION WITH RIP CORD, 600V RATING Note: - All lateral lines shall be 1" dia. unless otherwise noted on plan. - Irrigation controller shall be located in utility/mechanical room of one of the apartment buildings. coordinate location with general contractor. general contractor shall provide 110V power to controller and conduit to nearest landscape area. QUALITY IN THE COMMUNITY I NORTH 0 10 20 SCALE: 1" = 10'-0" DATE REVISIONS 09/20/19 — RK 03/19/20 — RK ULIEN I I QD co00 CD -t- z 00o J m 00 'ate U z D QZ wu � Z . C'7 Z o0 vsa m Q � wU =o N "' VU' Q m J ^ zQll' I W 4 CD w M = I� OF WA SN PND Kou' �ti 2 N • ro EXP. E ARO DATE REVISIONS 09/20/19 — RK 03/19/20 — RK ULIEN I I QD z J m � z Q IW . ' Lv � Q zw Cr � r�r^ V z Q � r SHEET TITLE SHEET NUMBER L 2 I 2OF I Al SxM PVC UNION, SCH. 80 (ON BOTH SIDES OF DOUBLE CHECK) DOUBLE CHECK VALVE ASSEMBLY VALVE BOX COVER FINISH GRADE AT LIP OF BOX IN TURF AND PAVED AREAS. 1" II BELOW LIP IN ALL Iii OTHER AREAS. TOP OF VALVE BOX II II= SHALL BE FLUSH III IRRIGATION VALVE BOX. WITH FINISH GRADE REFER TO IRRIGATION .III' SHEET NOTES OR J3" MIN. I I-II III SPECIFICATIONS < I I I �I w Lu III=I TO IRRIGATION SYSTEM gOX TO CLEAR PIPE < 0 L - . . IoW BY 1" MIN(TYP) PVC PIPE z ZI SCH. 40 MALE ADAPTER 3° MIN. PVC MAINLINE cp 6° MIN-- CONTINUOUS IN-CONTINUOUS BRICK OR ,T PRESSURE TREATED 91 LUMBER AROUND BASE `` I illlll CLEAN DRAIN ROCK NOTES: Y2" WIRE CLOTH GOPHER SCREEN. WRAP UP SIDES. 6"-12", CLEAN DRAIN ROCK NOTES: 1. COMPACT SOIL AROUND VALVE BOX TO SAME DENSITY AS UNDISTURBED ADJACENT SOIL. 2. ALL PIPE AND FITTINGS WILL BE SCHEDULE 40 PVC, EXCEPT UNIONS AND NIPPLES. 3. VALVE BOX SHALL NOT REST ON PIPES. PROVIDE 1" CLEAR AROUND ALL PIPES. BALL VALVE STANDARD VALVE BOX (18" DEPTH) SCH. 40 MALE ADAPTEE R WELL COMPACTED SUBGRADE 1. IF IRRIGATION SYSTEM IS TAPPED OFF OF A DOMESTIC SERVICE LINE, A HEAVY DUTY HAND BALL VALVE MUST BE INSTALLED IN AN OFFSET VALVE BOX (CARSON MODEL 1419 OR EQUAL) WITHIN 18" BEFORE THE DOUBLE CHECK VALVE ASSEMBLY. 2. HEAVY DUTY HAND BALL VALVE MUST BE INSTALLED AT THE WATER SUPPLY LINE DEPTH, I.E. BELOW THE FROST LINE. VALVE BOX EXTENSIONS AS NECESSARY TO EXTEND VALVE BOX DEPTH. DOUBLE CHECK VALVE NOT TO SCALE NOT TO SCALE O KEEP MULCH 6" FROM TREE TRUNK. ELECTRIC REMOTE II_ II Ld SLACK AROUND TREE. CONTROL ZONE VALVE TOP OF SPRINKLER (2 READ., LENGTH VARIES) 3» WALK OR CURB TOP OF VALVE BOX STANDARD VALVE HEAD SHALL BE FLUSH z SHALL BE FLUSH BOX (18" DEPTH) WITH FINISH GRADE MULCH. RAKE BACK WITH FINISH GRADE 2X2 PRESSURE TREATED STAKES 24" LENGTHS OF #5 REBAR I III -Z SCH. 40 a = MALE w ADAPTER ABOVE SURROUNDING =1 I Il I I' 1 I=1 I MI I .- , ,-, ' I Iftl I 111-1 1=1 I I= -I I 1=11 I.— w BOX TO CLEAR PIPE J z a w FERTILIZER TABLETS. \\ 11 T-111 I I -I 11-11I_- I I111� ;1!! I o HOLE FOR THE ROOTBALL, AND 11111-I _I I BY 1" MIN. (TYP.) X ��� PARALLEL TO THE ROAD (2 READ. LATERAL �1 1E,I KOUyS 2C ARE COILING AROUND SCH. 40 PERIMETER OF SYSTEM 15' LONG, CENTERED - SPRINKLER HEADS SCH. 40 MALE ADAPTER s" MIN. 90' ELL Z_ Q -I I I- I I M. NECESSARY TO oos o WELL vv :2 'sCOMPACTED N °0 II III—I CONTINUOUS BRICK OR SUBGRADE NIPPLE LATERAL LINE 12 GA. WIRE TREE TIE W/ RUBBER PRESSURE TREATED ����� MANUAL DRAIN VALVE LUMBER AROUND BASEMAINLINE WITH TEE �- PROTECTION AT THE TREE. MARLEX STREET ELL W/ MALE BARBED ELBOW OR ADAPTER CLEAN DRAIN ROCK (FASTEN LOOSELY) —III CURB POLYETHYLENE SWING PIPE GUTTER a0 FOR USE WHEN TREE IS WITHIN (18" MAX. LENGTH) NOTES: 2" DEPTH OF BARK MULCH IN STREET TREE SPECIFICATIONS: 6' DIAM. CIRCLE CENTERED ON TREE. KEEP MULCH 6" FROM TREE TRUNK. 1. TREES SHALL BE 2" TO 3" CALIPER PVC CLASS 200 LATERAL 1. ALL WIRE INSTALLATIONS WILL BE IN COMPLIANCE WITH APPLICABLE CODES. TRACE WIRE TAPED 2. TREES SHALL HAVE A MINIMUM 2X2 PRESSURE TREATED STAKES 2. TAPE AND BUNDLE WIRE EVERY 15 FT. SPACED EVENLY OUTSIDE THE - R ROOTBALL, PARALLEL TO THE 3. PROVIDE EXPANSION COILS AT EACH WIRE CONNECTION IN VALVE BOX. ROAD. (2 REQD.) THE GROUND LINE TO THE 4. COMPACT SOIL AROUND VALVE BOX TO SAME DENSITY AS UNDISTURBED ADJACENT SOIL. II_ 3. TREES SHALL BE SPACED 35 MANUAL DRAIN VALVE 5. ALL PIPE AND FITTINGS WILL BE SCHEDULE 40 PVC, EXCEPT UNIONS AND NIPPLES. 12 GA. WIRE TREE TIE W/ RUBBER 15 FEET FROM THE PROPERTY PROTECTION AT THE TREE. 6. VALVE BOX SHALL NOT REST ON PIPES. PROVIDE 1" CLEAR AROUND ALL PIPES. PVC TEE OR ELL FOR USE WHEN TREE IS NOT WITHIN 6' OF CURB AND/OR SIDEWALK CITY OF YELM MARLEX STREET ELL W/ MALE DEPT. OF PUBLIC WORKS 1 • THE GEOTEXTILE ROOT CONTROL SYSTEM SHALL BARBED ELBOW OR ADAPTER REMOTE CONTROLLED ZONE VALVE SPRINKLER HEADS � NOT TO SCALE SIDEWALK 2" DEPTH OF BARK MULCH. O KEEP MULCH 6" FROM TREE TRUNK. PRESSURE TREATED 4X6 II_ II Ld SLACK AROUND TREE. 2' O.C. 8' LONG, 2" DIA. ROUND-- (2 READ., LENGTH VARIES) TREE STAKE. SEE NOTES 12" MAX. 6" DIA. CLASS 200 SLEEVE I z PINNED IN PLACE WITH TWO NOT BE COVERED WITH EE TIE HEIGHT MULCH. RAKE BACK 'PROX. 4' 2X2 PRESSURE TREATED STAKES 24" LENGTHS OF #5 REBAR I III -Z � ABOVE SURROUNDING 000°00° SPACED EVENLY OUTSIDE THE S.S. CLAMPS FERTILIZER TABLETS. \\ NOTES: OPENING IN SIDE TO - -I I III HOLE FOR THE ROOTBALL, AND REMOTE CONTROL X ��� PARALLEL TO THE ROAD (2 READ. GEOTEXTILE ROOT CONTROL �1 1E,I KOUyS 2C ARE COILING AROUND ZONE VALVE PERIMETER OF SYSTEM 15' LONG, CENTERED ROOTBALL, TEASE THEM TRENCH BACKFILL MAINLINE (MIN. 1" GAP). -I I I- I I M. NECESSARY TO ON TREE. (TWO REQD.) vv :2 i PER SPECIFICATIONS II III—I NIPPLE LATERAL LINE 12 GA. WIRE TREE TIE W/ RUBBER 04 °O ����� MANUAL DRAIN VALVE _ 'IIII III=I PROTECTION AT THE TREE. TO SPRINKLERS 6 (FASTEN LOOSELY) —III CURB GUTTER a0 FOR USE WHEN TREE IS WITHIN 6' OF CURB AND/OR SIDEWALK 2" DEPTH OF BARK MULCH IN STREET TREE SPECIFICATIONS: 6' DIAM. CIRCLE CENTERED ON TREE. KEEP MULCH 6" FROM TREE TRUNK. 1. TREES SHALL BE 2" TO 3" CALIPER MEASURED 6" ABOVE THE BASE. TRACE WIRE TAPED 2. TREES SHALL HAVE A MINIMUM 2X2 PRESSURE TREATED STAKES 6 FOOT FREE -OF -BRANCH SPACED EVENLY OUTSIDE THE - R ROOTBALL, PARALLEL TO THE CLEARANCE, MEASURED FROM ROAD. (2 REQD.) THE GROUND LINE TO THE FIRST BRANCH. II_ 3. TREES SHALL BE SPACED 35 MANUAL DRAIN VALVE FEET ON CENTER STARTING 12 GA. WIRE TREE TIE W/ RUBBER 15 FEET FROM THE PROPERTY PROTECTION AT THE TREE. LINE. (FASTEN LOOSELY) FOR USE WHEN TREE IS NOT WITHIN 6' OF CURB AND/OR SIDEWALK CITY OF YELM NOTES: DEPT. OF PUBLIC WORKS 1 • THE GEOTEXTILE ROOT CONTROL SYSTEM SHALL APPROX. 3 C.F. III BE 12 INCH BIOBARRIER STRIPS, OR APPROVED EQUAL. STREET TRE E 2• WIRE TREE TIE SHALL BE 42" ABOVE THE GROUND � 3. FINISH GRADE FOR BARK MULCH SHALL BE 1 TO 2 INCHES BELOW SURROUNDING GRADE APPROVED DWG. NO. CLEAN DRAIN 2-19 PUBLIC WORKS DIRECTOR DATE DOUBLE CHECK VALVE - DES. DWN. CKD. DATE JEG S -C S -C S -C 10/3/94. NOT TO SCALE WIRE TREE TIE WITH RUBBER HOSE PROTECTIVE SHEATH AROUND TRUNK. TWISTED WIRE SHALL BE ON STAKE. ALLOW Y2" SLACK AROUND TREE. 8' LONG, 2 DIA. ROUND TREE STAKE. SEE NOTES FOR MORE INFORMATION ROOTBALL CROWN SHALL NOT BE COVERED WITH MULCH. RAKE BACK MULCH IF NECESSARY SET ROOTBALL V-2" ABOVE SURROUNDING GRADE FERTILIZER TABLETS. 2"-6" DEPTH PLANTING BACKFILL. SEE SHEET NOTES FOR MORE INFORMATION. LOOSEN ROOTS WHEN PLANTING. IF ROOTS ARE COILING AROUND PERIMETER OF ROOTBALL, TEASE THEM AWAY AND CUT IF NECESSARY TO ENCOURAGE OUTWARD GROWTH. COMPACTED MOUND OF PLANTING BACKFILL $TAI. ann n rvmv"vivrvi yr 12" BELOW BOTTOM OF PLANTING PIT INTO UNDISTURBED SOIL NOTES: QUALITY IN THE COMMUNITY I SET VALVE BOX FLUSH WITH 6" ECONO BOX SURROUNDING FINISHED GRADE A d v — — I JL`T A 6,. 12„ 1419 12 1419 910 :a. v CO CO (0 c0 •v ••d '.a .a v,d •.. v 'A vd A.' • A e v 4• P A ,• NOTES: VALVE BOX INSTALLATION NOT TO SCALE WIRE TREE TIE WITH RUBBER SPACING FINISH GRADE 12 O.C. II_ II Ld SLACK AROUND TREE. 2' O.C. 8' LONG, 2" DIA. ROUND-- 4" MIN, TREE STAKE. SEE NOTES 12" MAX. 6" DIA. CLASS 200 SLEEVE I z PERIMETER OF ROOTBALL, TEASE THEM AWAY AND CUT IF NOT BE COVERED WITH EE TIE HEIGHT MULCH. RAKE BACK 'PROX. 4' MULCH IF NECESSARY (LENGTH AS REQUIRED). CUT I III -Z � ABOVE SURROUNDING 000°00° GRADE S.S. CLAMPS FERTILIZER TABLETS. \\ NOTES: OPENING IN SIDE TO - -I I III w REMOTE CONTROL X ��� LOOSEN ROOTS WHEN ACCOMODATE NIPPLE FROM �1 1E,I KOUyS 2C ARE COILING AROUND ZONE VALVE PERIMETER OF z ¢ ROOTBALL, TEASE THEM TRENCH BACKFILL MAINLINE (MIN. 1" GAP). -I I I- I I M. NECESSARY TO 1 "X6" SCH. 80 vv :2 i PER SPECIFICATIONS II III—I NIPPLE LATERAL LINE 04 °O ����� MANUAL DRAIN VALVE _ 'IIII III=I TO SPRINKLERS � � —III � a0 �j 1"X4" SCH. 80 NIPPLE II� III IRRIGATION MAINLINE N\� TRACE WIRE TAPED — I I = =III = II I I - R TOPOF MAINLINE I I-_ o o II_ MAINLINE &TEE MANUAL DRAIN VALVE / O —I I Oo o o0 0 o I -I \\ APPROX. 3 C.F. III o o� oo o o o IIII � CLEAN DRAIN Oo DOUBLE CHECK VALVE - 0o Oo o IIII ROCK SUMP =III 0 LATERAL LINE PIPING —I I O o 0 OCD I MAINLINE PIPING CONTROL WIRE TAPED I I o 0 0 00 0 o I WELL COMPACTED TO BOTTOM OF i I I o 00 o O c0 I -I I SUBGRADE IRRIGATION WATER METER - '1 MAINLINE ®10' O.C.IIII o 0 0 0 Oo O o IIIII VIII o 0 o O� o oolllll�� „—I I I RRI GA TION TRENCH MANUAL DRAIN VALVE POINT OF CONNECTION NOT TO SCALE NOT TO SCALE NOT TO SCALE TOP OF VALVE BOX QUICK COUPLING VALVE SHALL BE FLUSH FINISH GRADE WITH FINISH GRADE A d v — — I JL`T A 6,. 12„ 1419 12 1419 910 :a. v CO CO (0 c0 •v ••d '.a .a v,d •.. v 'A vd A.' • A e v 4• P A ,• NOTES: VALVE BOX INSTALLATION NOT TO SCALE 1. EACH TREE SHALL RECEIVE A 4" HT. WATERING WELL. TREES IN LAWN AREAS SHALL RECEIVE NO WATERING WELL AND SHALL BE PLANTED IN THE CENTER OF A 3' DIA. MULCH CIRCLE UNLESS OTHERWISE SPECIFIED. 2. FOR TREES TALLER THAN 6 FT. HT., INSTALL TREE STAKES PERPENDICULAR TO PREVALENT WIND DIRECTION, UNLESS ADJACENT TO A WALK OR DRIVEWAY IN WHICH CASE IT SHALL BE PARALLEL TO PAVEMENT. 3. REMOVE TREE STAKES ONE GROWING SEASON AFTER INSTALLATION. 4. SEE SHEET NOTES FOR ADDITIONAL INFORMATION. CONIFER TREE PLANTING EDGE OF PLANTING BED OR LAWN AREA EDGE OF PAVING OR GRAVEL AREA 1. CENTER VALVE BOX OVER VALVE TO FACILITATE REMOVAL AND SERVICING. 2. SET BOXES PARALLEL TO EACH OTHER AND PERPENDICULAR TO EDGE. 3. AVOID OVER COMPACTING SOIL AROUND VALVE BOXES TO PREVENT COLLAPSE AND DEFORMATION OF VALVE BOXES. APPROX. 3/3 THE PLANT SPACING TO THE PLANTING BED EDGE. SEE NOTES FOR EXAMPLES. 000000 TRIANGULAR 0 00 O SPACING PLANT ON -CENTER 0 (O.C.) SPACING - 0 SEE PLANT LIST • FOR MORE INFORMATION ADJUST PLANT SPACING FOR 0 n - MOST EVEN PLANT COVERAGE NOTES: PLANT WIRE TREE TIE WITH RUBBER SPACING HOSE PROTECTIVE SHEATH 12 O.C. AROUND TRUNK. ALLOW Y2" 18" O.C. SLACK AROUND TREE. 2' O.C. 8' LONG, 2" DIA. ROUND-- 4" MIN, TREE STAKE. SEE NOTES 12" MAX. FOR MORE INFORMATION PLANT SPACING ROOTBALL CROWN SHALL ---\ PERIMETER OF ROOTBALL, TEASE THEM AWAY AND CUT IF NOT BE COVERED WITH EE TIE HEIGHT MULCH. RAKE BACK 'PROX. 4' MULCH IF NECESSARY !OVE FINISH ADE SET ROOTBALL 1"-2" #4 REBAR W/ ABOVE SURROUNDING 000°00° GRADE S.S. CLAMPS FERTILIZER TABLETS. \\ NOTES: 2"-6" DEPTH PLANTING BACKFILL. \� SEE SHEET NOTES FOR MORE INFORMATION. - LOOSEN ROOTS WHEN MIN. PLANTING. IF ROOTS KOUyS 2C ARE COILING AROUND 2 PERIMETER OF ROOTBALL, TEASE THEM tico AWAY AND CUT IF NECESSARY TO ENCOURAGE OUTWARD GROWTH. COMPACTED MOUND OF—/ PLANTING BACKFILL NOTES: 1. EACH TREE SHALL RECEIVE A 4" HT. WATERING WELL. TREES IN LAWN AREAS SHALL RECEIVE NO WATERING WELL AND SHALL BE PLANTED IN THE CENTER OF A 3' DIA. MULCH CIRCLE UNLESS OTHERWISE SPECIFIED. 2. FOR TREES TALLER THAN 6 FT. HT., INSTALL TREE STAKES PERPENDICULAR TO PREVALENT WIND DIRECTION, UNLESS ADJACENT TO A WALK OR DRIVEWAY IN WHICH CASE IT SHALL BE PARALLEL TO PAVEMENT. 3. REMOVE TREE STAKES ONE GROWING SEASON AFTER INSTALLATION. 4. SEE SHEET NOTES FOR ADDITIONAL INFORMATION. CONIFER TREE PLANTING EDGE OF PLANTING BED OR LAWN AREA EDGE OF PAVING OR GRAVEL AREA 1. CENTER VALVE BOX OVER VALVE TO FACILITATE REMOVAL AND SERVICING. 2. SET BOXES PARALLEL TO EACH OTHER AND PERPENDICULAR TO EDGE. 3. AVOID OVER COMPACTING SOIL AROUND VALVE BOXES TO PREVENT COLLAPSE AND DEFORMATION OF VALVE BOXES. APPROX. 3/3 THE PLANT SPACING TO THE PLANTING BED EDGE. SEE NOTES FOR EXAMPLES. 000000 TRIANGULAR 0 00 O SPACING PLANT ON -CENTER 0 (O.C.) SPACING - 0 SEE PLANT LIST • FOR MORE INFORMATION ADJUST PLANT SPACING FOR 0 n - MOST EVEN PLANT COVERAGE NOTES: PLANT SPACE FROM PLANT SPACING CENTER TO PLANTING BED EDGE 12 O.C. 8" 18" O.C. 12 2' O.C. V-4" 4" MIN, 12" MAX. 3' O.C. 4' O.C. 2' 2'-8" 5' O.C. 3'-4" PLANT SPACING TREE TIE HEIGHT APPROX. NOT TO SCALE PERIMETER OF ROOTBALL, TEASE THEM AWAY AND CUT IF 4' ABOVE FINISH GRADE o0 ::::::.: i, MIN. STAKE SHALL EXTEND \/\� A MINIMUM OF 12" INTO UNDISTURBED i NATIVE SOIL \\�\\>\\\ 2X ROOTBALL/�' WIDTH 1. EACH TREE SHALL RECEIVE A 4" HT. WATERING WELL. TREES IN LAWN AREAS SHALL RECEIVE NO WATERING WELL AND SHALL BE PLANTED IN THE CENTER OF A 3' DIA. MULCH CIRCLE UNLESS OTHERWISE SPECIFIED. 2. FOR TREES TALLER THAN 6 FT. HT., INSTALL TREE STAKES PERPENDICULAR TO PREVALENT WIND DIRECTION, UNLESS ADJACENT TO A WALK OR DRIVEWAY IN WHICH CASE IT SHALL BE PARALLEL TO PAVEMENT. 3. REMOVE TREE STAKES ONE GROWING SEASON AFTER INSTALLATION. 4. SEE SHEET NOTES FOR ADDITIONAL INFORMATION. DECIDUOUS TREE PLANTING ►N>fiC�1��H_l�� PLANTS ON EDGE OF PLANTING BED SHAPE FOLLOW SHAPE OF BED AS CLOSELY AS PRACTICAL. ROOTBALL CROWN SHALL BE ABOVE MULCH. RAKE BACK MULCH IF NECESSARY SET ROOTBALL 1"-2" ABOVE ti, MULCH - SURROUNDING GRADE Gv' TYPE AND DEPTH PER EACH SHRUB SHALL RECEIVE �' �^� SHEET NOTES. A WATERING WELL. NO WATER WELL IN LAWN AREA. C=) v FERTILIZER TABLETS. � 2"-6" DEPTH rn I PLANTING BACKFILL. SEE SHEET VALVE BOX NOTES FOR MORE INFORMATION. � o 'acD LOOSEN ROOTS WHEN PLANTING. IF /\ ROOTS ARE COILING AROUND CD x¢ PERIMETER OF ROOTBALL, TEASE THEM AWAY AND CUT IF O! �\ o0 1" U.S. THREADED NECESSARY TO ENCOURAGE a0000000c OUTWARD GROWTH. ONE END PVC NIPPLE #4 REBAR W/ /\\ 000°00° (MIPT) AS RISER S.S. CLAMPS oc °g00000,°0 o„o'. NOTES: 1" 'LASCO' OR EQUAL WATERING WELL HEIGHTS: 1 GAL. CONT. - 1" HT. 2 & 3 GAL. CONT. - 2" HT. 5 GAL. CONT. & LARGER - 4" HT. REMOVE BURLAP FROM ROOTBALL AS MUCH AS POSSIBLE WITHOUT DAMAGING INTEGRITY OF ROOTBALL. SHRUB PLANTING ►L•]iI•>��•LT�� \6" MIN. i �OMPACTEI MOUND OF PLANTING BACKFILL. II�II I I I IIIIIII IIII C=) v �H, J 10" DIA. TT rn I a VALVE BOX WASHED PER GRAVEL � o 'acD (3" MIN. DEPTH) _1 ° CD x¢ II ooc °0000 °oc o0 1" U.S. THREADED y a0000000c ,0o0000_c ooc0000, ONE END PVC NIPPLE #4 REBAR W/ 00 0 0 000°00° (MIPT) AS RISER S.S. CLAMPS oc °g00000,°0 o„o'. ° 0°0 0`_ 000 1" 'LASCO' OR EQUAL PRE -FABRICATED SWING - JOINT (SCHEDULE 80) \ 1" NIPPLE - LENGTH AS \ NECESSARY TO ACCOMMODATE \ 45' ANGLE (SOLVENT JOINT) \\\ ------------------- --- ---- - -- MAINLINE PIPE INSTALL WITH USE SECOND MALE ADAPTER (FROM SWING JOINT 30-45' ANGLE KIT) AND SOLVENT JOINT PVC NIPPLE INTO NOTES: SOLVENT JOINT SUPPLY LINE OUTLET TEE OR ELL. 1. VALVE KEY HANDLE TO CLEAR TOP OF BOX BY 2" MINIMUM. 2. THREADED ONE END NIPPLE AND SOLVENT JOINT NIPPLES TO BE SCHEDULE 80 PVC. 3. SUPPLY LINE TEE, THREADED ONE END NIPPLE AND SOLVENT JOINT NIPPLES NOT INCLUDED IN PRE -FABRICATED SWING JOINT. QUICK COUPLER NOT TO SCALE ROOTBALL CROWN SHALL BE ABOVE MULCH. RAKE BACK MULCH IF NECESSARY PLANTING BACKFILL SEE SHEET NOTES FOR MORE INFORMATION. I GAL. CONT. $ LARGER GROUNDCOVER PLANTING NOT TO SCALE MULCH - TYPE AND DEPTH PER SHEET NOTES. 00 \ ROOTS WHEN PLANTING. IF ROOTS ARE COILING AROUND PERIMETER OF ROOTBALL, TEASE THEM AWAY AND CUT IF NECESSARY TO ENCOURAGE OUTWARD GROWTH. FERTILIZER TABLET 4" POT DATE REVISIONS 09/20/19 - RK 03/19/20 - RK 1 ULIEN I I V C=) v z 0` 00 0 rn I � rn � o 'acD U� CD x¢ Ld L � z y $o � Cf•� v1a a' m� Q w U, 0 o U' Lo N"' L7 Q m J w o OF WA SN PND KOUyS 2C 2 2 tico EXP. 0'\ I \� SOgPE ARO DATE REVISIONS 09/20/19 - RK 03/19/20 - RK 1 ULIEN I I V v 1 z J — U 0 Ld � w Q z� cr 0 (Q �L z Q � J SHEET NUMBER 3 SHEET TITLE 3OF I I 3 v 1 J — 0 U z - Q � J SHEET NUMBER 3 3OF I I 3