Loading...
105098782 THE MEADOWS AT MILL PONDN Vicinity Map 46.9359, -122.6115 Owner / Developer Contact Info officeATTN: RUSH RESIDENTIAL, INC 6622 WOLLOCHET DR GIG HARBOR, WA 98335 JOE FLANSBURG 253.858.3636 THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) PSE No No No Yes Yes Yes No YesDeveloper "Flagging Required" "Outages Required" "Locates Required" ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.) EROSION & SEDIMENT CONTROL REQUIREMENTS NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES (LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING 0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE & ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. GAS PHONE CABLE TV 511881653 105098782 N/A 105099387 N/A N/A N/A N/A N/A N/A N/A N/A 511881654 107061204 N/A 106381434 N/A N/A PROJECT PHASE PWR NOTIF#ORDER# Superior Street Light Relocation Removal Temporary Job Order Distribution Service Stubs HP Svc/MSA 10. 9. 8. 7. 6. 5. 4. 3. 2. 1.THE CUSTOMER IS RESPONSIBLE FOR PROVIDING ALL TRENCHING, PER THE TRENCH PROFILE, AND ALL EXCAVATIONS AT THE TRANSFORMER/HANDHOLE VAULT SITES SUCH THAT PSE FACILITIES WILL MATCH FINAL GRADE. VAULT HOLES WILL HAVE STABLE LEVEL BOTTOMS. CUSTOMER WILL PROVIDE 6" OF CRUSHED ROCK FOR VAULT BEDDING. ALL TRENCHES WILL HAVE 6" OF WASHED SAND COVER AND 4" BEDDING FOR ALL CONDUITS. THE CUSTOMER WILL PROVIDE SELECT BACKFILL, IF REQUIRED, AND COMPACTION AS NECESSARY. THE CUSTOMER IS RESPONSIBLE FOR DISPOSAL OF ALL NATIVE SPOILS NOT SUITABLE FOR USE AS BACKFILL. ALL TRENCHES MAY BE JOINT WITH GAS, TELEPHONE AND TV CABLE. ALL CABLES/CONDUITS TO BE INSTALLED IN CUSTOMER'S TRENCH AT THE DEPTH INDICATED IN TRENCH DETAIL (DEPENDENT UPON SIZE OF CONDUIT BEING INSTALLED TO MEET MIN 36" OF COVER). INSTALL CABLE ID TAGS AT EACH END OF THE PRIMARY CABLES PER THE CIRCUIT ONE-LINE DIAGRAM. UNLESS OTHERWISE SPECIFIED BY MUNICIPALITIES, INSTALL PVC (DB-120) ROAD CROSSINGS AS INDICATED ON THE CROSSINGS CONDUIT TABLE & AS SHOWN ON WORK SKETCH. CROSSINGS SHALL BE INSTALLED BY CUSTOMER/DEVELOPER PER PUGET SOUND ENERGY STANDARDS. AT SYMBOL: INSTALL UNDERGROUND PRIMARY CABLES IN CONDUIT. CABLE LENGTH AND CONDUIT SIZE AS INDICATED ON PRIMARY CABLE & CONDUIT TABLE. AT SYMBOL: INSTALL 600 VOLT UG SECONDARY CABLES IN CONDUIT. CABLE/CONDUIT SIZE AND LENGTH AS INDICATED ON SECONDARY CABLE & CONDUIT TABLE. AT SYMBOL: INSTALL MINI-PAD HANDHOLE & PADMOUNT TRANSFORMER. ADDITIONAL EQUIPMENT AS INDICATED ON VAULT TABLE. AT SYMBOL: INSTALL SECONDARY PEDESTAL/HANDHOLE W/ (3) MULTI-CONNECTORS. SIZE AS INDICATED ON SECONDARY HH/PEDESTAL TABLE. (EXCAVATION: 3' SQ.) AT SYMBOL: INSTALL JUNCTION BOX HANDHOLE. ADDITIONAL EQUIPMENT AS INDICATED ON VAULT TABLE. AT SYMBOL: INSTALL SECONDARY CABLE & CONDUIT STUB-OUT. AT SYMBOL: INSTALL STREET LIGHTING STANDARD. SIZE AND TYPE OF STANDARD/LUMINARIE AS INDICATED ON STREET LIGHTING TABLE. (CUSTOMER TO EXCAVATE & INSTALL CORRUGATED STREET LIGHT TUBES FOR PLACEMENT OF THE STREET LIGHT STANDARDS. ) INCLEMENT WEATHER CONDITIONS MAY CAUSE DELAYS IN CONSTRUCTION TIMES AND DATES. POWER GENERAL NOTES - PLAT PROJECT 105098782107061204Phone INTOLIGHT Contact Information: LARS LARSON 425.456.2701 DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP D. BETTENCOURT 206.445.5958 . C.GESTRING 253.234.6394 1.13.22 C. GESTRING 253.234.6394 1.13.22 A. VASQUEZ .12.14.21 REDT # ( RW-124370 )YELM THE MEADOWS AT MILL POND 1Ø PRIMARY U/G LINE EXTENSION - 21 S/F LOTS P# 22730220600; 700 BLOCK MILL ROAD SE, YELM, WA 98597 PUGET SOUND ENERGY N/A IP 344-60 107061204 105098782 N/A 1 OF 4 THURSTON 344 CIONC QSTHLE 30SE-T17N-R02E 284.044 284.044 1702E120 1702E116 1702E118 YEL-26 COMCAST TED AXTELL . WAVE BROADBAND . . RIGHT OF WAY CAROLYN BANASKY 253.476.6416 . . . 11. E-Mail: Cell Phone: Project Manager Contact Information: Manager:DON BETTENCOURT 206.445.5958 Don.Bettencourt@pse.com x x x Standoff Bracket 15" Min Length Conduit Clamp Conduit Field Face Quadrant Climbing SpaceRoad Face Quadrant Climbing Space 5" Min CL LCDirection of Vehicular Traffic CONDUIT RISER PLACEMENT DETAIL TOP VIEW NOT TO SCALE ... ... ... x JFLANSBURG@THERUSHCOMPANIES.COM VAULT DETAIL @ V01 - V03 NOT TO SCALE TOP VIEW SIDE VIEW EXCAVATION: 4-2/3 CUBIC YARDS Rock Crushed 6" 3'-6" 2" 6' 6' 48"42" 36" 38" 42" Struts FRONT FRONTTYPICAL NOTCH-OUT FOR TRANSFORMER, NOT TO SCALE & SECONDARY PEDESTAL/HANDHOLE BACK OF EASEMENT STANDARD EASEMENT LINE ROW 10' PL 1' 4' - 5' Min. 1' 7'7' TRANSFORMER (WHEN PRESENT) 42" 45°42" 1' 45°Property LineRoad Side Top View of Mainline Trench for Single Stubout Location 4'Property LineRoad Side Top View of Mainline Trench for Pedestal or Double Stubout Location 42"45° 4' 45° STUBOUT EXCAVATION DIMENSIONS NOT TO SCALE JOINT TRENCH DETAIL NOT TO SCALE JOINT TRENCH DETAIL NOTES: 1. If the final backfill contains rocks greater than 8 inches in diameter , install 12 inches compacted sand shading across the full width of the trench. * If the final backfill contains rocks 8 inches in diameter or smaller , install 6 inches compacted sand shading across the full width of the trench. * 2. Rocks greater than 10 inches diameter are not permitted in the final backfill. 3. Sand bedding is required under PSE gas pipe. Bedding is not required for the full width of the trench; it shall extend from the side of the trench nearest to where the gas main/service is installed to a minimum of 6 inches on the opposite side of the gas line. 4. Utilities shall not be stacked over the gas line in the trench. 5. If wet utilities will be included in the trench, please contact PSE or local power company directly for clearance requirements. 6. Reduced clearance of 4 inches between power and communication, must have approval of the communications companies. * Alternatives to full-width trench shading require PSE approval. Primary & Secondary-Mainline Gas & Communications (NTS) ROAD SIDE NATIVE SECONDARY POWER PEDESTAL MATERIAL P/L Power Secondary Power Primary Conduit Tel. & TV 12" Min 12" Sand Cover when gas line is in trench Sand 6" or 12" 4" Sand Bedding 1' 36" Cover 42" Gas 12" 18" Lower 2" 10" Pedestal PSE 10' FRONTAGE EASEMENT 1' Cover ROAD SIDE MINIPAD MINIPAD FIELD SIDE VAULT 6" of crushed rock (base for vault) P/L Power Secondary Power Primary Gas 12" Min Horizontal Separation Communications 42" Min 21"1' Feeder 38" 2" 4" Sand Bedding 12" Sand Cover 36" Cover 4" Sand Bedding 42" 6" Additional depth when Feeder is required PSE 10' FRONTAGE EASEMENT 1' TRANSFORMER Final Backfill Initial Backfill Trench Depth 42" - 48" Primary Dirt Pile Final Grade 24" Min 36" Min Cover Over Power 48" Max Depth Final Backfill Gas 4" Sand Bedding Property Line intercept (depth varies). SidewalkCurb Location of roof drain 48" Typical Width may vary per Number of Utilities and Conduits 6" or 12" Min Sand Shading Over Gas after Compaction 12" Min R/W or Excavated 12" Typical Power Secondary Power TV & TEL 12" Min 12" Min Separation 4,5 1,2 1 3 6 6" or 12" Min Sand Shading Over Power after Compaction1 COOLING 5' MIN 5' MIN 10' MIN 5' MIN FINS ACCESS CONCRETE PAD MINIMUM CLEARANCES FOR PSE EQUIPMENT NOT TO SCALE CURB OR EDGE OF PAVEMENT CURB OR EDGE OF PAVEMENT 5' MIN ROAD OR PARKING AREA TYP. PAD & TRANS- FORMER 3' MIN 3' MIN DOOR ACCESS DOOR REQUIRED WORK SPACE AREA 3' MIN @ H1A, H2A & H3A SHALL BE STAGGERED CONNECTOR BARS IN THE FRONT NEUTRALS SHALL BE 18" 16" 13" 12"10" 2" 10" Pedestal will accept up to six 3" conduits SEALED WITH FOAM CONDUIT SHALL BE 120 PVC CONDUIT ELBOWS TYPICAL 24" RADIUS DB SIDE VIEW WITH CONDUIT 10" 18" 16" 13" 10" 2" 36" FRONT VIEW WITH CONDUIT SECONDARY PEDESTAL DETAIL NOT TO SCALE SITE MINIMUM CLEARANCES FOR PSE EQUIPMENT NOT TO SCALE OIL-FILLED TRANSFORMER TRANSFORMER APPROVED AREA COMBUSTIBLE BUILDING WALLS & ROOF3' 3' REDUCED FLAMMABILITY 3' Oil-Filled Equipment Clearances per PSE Std 0700.1500 If the oil-filled equipment is adjacent to… Clearance Requirement Combustible walls or roof (including stucco).10 FT Combustible walls using a reduced-flammability transformer. Gas service meter relief vent.3 FT Noncombustible walls, soffits, and roofs (including brick, concrete, steel and stone) providing the side of the transformer facing the wall does not have doors. Materials that pass UBC Std. 2-1 or ASTM E136-79 are considered to be noncombustible. 3 FT Generators, customer-owned transformers, fire sprinkler valves, standpipes, and fire hydrants.6 FT Doors, windows, vents, fire escapes, or other building openings.10 FT The water's edge of a swimming pool or any body of water.15 FT Facilities used to dispense or store LP, hazardous liquids, or fuel.20 FT Individual domestic and irrigation wells. Clearance not required on pole mounted transformers (pole placement still applies as stated in 6450.3000), TUT's installed in sealed vaults, 7200V single-phase padmount transformers 50kva or less, and reduced flammability oil. 100 FT s s s s ssssssss s s s ssssss0+75 1+00 2+00 3+00 4+00 5+00 6+00 0+42 0+50 0+56 0+080+170+250+330+40709 ABC#2ACSRFEEDYEL 26 #2ACSRABCFUSE @ 40T SW#T86556 MON IRR LOT 15 LOT 14 LOT 21 LOT 13 LOT 20 LOT 19 LOT 18 LOT 17 LOT 16 LOT 6LOT 5LOT 4 LOT 11 LOT 3 LOT 10 LOT 2 LOT 9LOT 1 LOT 8 TRACT 'A'LOT 7 LOT 12 TRACT 'B'#4ACSR#4AC S R B104TH PL SE 104TH AVE SE MILL RD SEMEADOWS ROAD 1 TO BE REMOVED 58'50' R50' 'A' DEVELOPER RESPONSIBLE FOR CONDUIT/WIRE FROM H1A TO METER LOCATION 1" = 50' DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP D. BETTENCOURT 206.445.5958 . C.GESTRING 253.234.6394 1.13.22 C. GESTRING 253.234.6394 1.13.22 A. VASQUEZ .12.14.21 REDT # ( RW-124370 )YELM THE MEADOWS AT MILL POND 1Ø PRIMARY U/G LINE EXTENSION - 21 S/F LOTS P# 22730220600; 700 BLOCK MILL ROAD SE, YELM, WA 98597 PUGET SOUND ENERGY N/A IP 344-60 107061204 105098782 1" = 50'2 OF 4 THURSTON 344 CIONC QSTHLE 30SE-T17N-R02E 284.044 284.044 1702E120 1702E116 1702E118 YEL-26 COMCAST TED AXTELL . WAVE BROADBAND . . RIGHT OF WAY CAROLYN BANASKY 253.476.6416 . . . SITE PLAN CIRCUIT LOADING TABLE AS OF EXIST. PEAK LOAD EST. NEW LOAD TOTAL CIRCUIT: A PHASE B PHASE C PHASE YEL-26 6.11.21 260 256 272 0 18 0 260 274 272 ... ... ... SCHED.SQ. FT. MAX LRC = CIRCUIT FEET ADDED: 600' 17 3200 115 AMPS THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) P02 & ALL RELATED FACILITIES TO BE REMOVED ON A SEPARATE WORK ORDER # 101145190 CUSTOMER OWNED AND INSTALLED SECONDARY WIRE TABLE BLDG.# OF METERS SOURCE # OF RUNS WIRE SIZE REMARKS -1 H1A 1 #1 MONUMENT -1 H1A 1 #1 IRRIGATION ALL CUSTOMER-OWNED WIRE MUST BE INSTALLED ACCORDING TO THIS TABLE LRC: % V. Drop: % Flicker: Sq. Footage: Panel Size: Heat Type: Est. Demand: Units: BUILDING #MONUMENT N/A N/A TBD N/A 1KW N/A 3.3 @ H1A 2.8 @ H1A SITE SPECIFIC NOTES At P01 (559155-147281) 1965 CLASS 3 - 40' -INSTALL 2" PRIMARY RISER ON NEW STANDOFF BRACKETS -STIRRUP (2254000) -ALUM "H" CONNECTOR (2167000) (RIS2CSS) 6042.1000 -FUSE @ 40T (3412500), TAP 'B' PHASE -INSTALL SWITCH# T86556 -INSTALL 1Ø TERM ON NEW BI-UNIT (8721000) FIBERGLASS ARM W/ LINKBREAK C/O & SURGE ARRESTOR (TSU1C1) 6043.1000 LRC: % V. Drop: % Flicker: Sq. Footage: Panel Size: Heat Type: Est. Demand: Units: BUILDING #IRRIGATION N/A N/A TBD N/A 1KW N/A 3.3 @ H1A 2.8 @ H1A DEDICATED FACILITIES (105098782) for RF Transformers SITE SPAN ADDITIONAL REMARKS LABOR UNITS #FROM TO FOOTAGE V01-V03 ---REDUCED FLAMMABILITY - CROSSING CONDUIT TABLE X-ING # LOCATION GAS POWER XING LENGTH ASBUILT LOCATION TYPE OF CROSSING (Feeder, Primary, Secondary, etc.)FROM TO SIZE (IN)TYPE QTY LOCATION SIZE (IN)TYPE QTY X01 'A'LOT 21 4 40 1 S 2 DB120 1 70 ( )' NCL GAS MAIN, PRIMARY X02 LOT 18 LOT 2 2 40 1 W 3 DB120 1 70 ( )' ECL GAS SVC, SECONDARY X03 LOT 16 LOT 4 2 40 1 W 3 DB120 2 70 ( )' ECL GAS SVC, SECONDARY X04 LOT 15 LOT 5 2 40 1 E 3 DB120 2 70 ( )' ECL GAS SVC, SECONDARY 2" PVC PLUG /CAPS = 6 2" YELLOW SCH 40 PVC = 210 FT 2" DB120 GREY PVC = 70 FT 2" PVC PLUG /CAPS = 2 4" PVC PLUG /CAPS = 2 4" YELLOW SCH 40 PVC = 70 FT 3" DB120 GREY PVC = 350 FT 3" PVC PLUG /CAPS = 10 COORDINATE WITH PSE ON MAINTAINING ELECTRIC SERVICE TO EXISTING CUSTOMERS DURING ALL PHASES OF CONSTRUCTION →SEE PSE HANDBOOKS← SEE 1218 (SF),1220 (MF), 6080, FOR TRENCH SEE 3061, 2809 DEVELOPER TO COORDINATE WITH PSE PROJECT MANAGER & SERVICE PROVIDER PRIOR TO EXCAVATING WITHIN 3' OF LOCATE MARKS OF PSE ENERGIZED FACILITIES DEVELOPER TO PROVIDE TYPICAL 10' PSE FRONTAGE EASEMENT FOR OPERATION AND MAINTENANCE OF PSE EQUIPMENT. EASEMENT TO BE CLEAR OF ALL BUILDING OVERHANGS AND FOUNDATION FOOTINGS NEW 1/O AL EJC871BØABC#2ACSRFEEDYEL 26 #2ACSRABCFUSE @ 40T #4ACSR#4AC S R B'A' SW#T86556 NEW 1/O AL EJC872-BØ NEW 1/O AL EJC873-BØ AØAAA385 BØAAA386 CØAAA387 BØAAX387 DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP D. BETTENCOURT 206.445.5958 . C.GESTRING 253.234.6394 1.13.22 C. GESTRING 253.234.6394 1.13.22 A. VASQUEZ .12.14.21 REDT # ( RW-124370 )YELM THE MEADOWS AT MILL POND 1Ø PRIMARY U/G LINE EXTENSION - 21 S/F LOTS P# 22730220600; 700 BLOCK MILL ROAD SE, YELM, WA 98597 PUGET SOUND ENERGY N/A IP 344-60 107061204 105098782 AS SHOWN 3 OF 4 THURSTON 344 CIONC QSTHLE 30SE-T17N-R02E 284.044 284.044 1702E120 1702E116 1702E118 YEL-26 COMCAST TED AXTELL . WAVE BROADBAND . . RIGHT OF WAY CAROLYN BANASKY 253.476.6416 . . . ... ... ... EX OVERHEAD CIRCUIT MAP 1702E116 SCALE: 6" = 1 MILE NEW PRIMARY UNDERGROUND CIRCUIT ONE-LINE DIAGRAM NOT TO SCALE EX UNDERGROUND CIRCUIT MAP 1702E118 NOT TO SCALE SITE THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) VAULT & EQUIPMENT TABLE SITE #GRID # VAULT SIZE & COVER TYPE & SIZE EQUIPMENT IN VAULT PRIMARY BUSHINGS TRANSFORMER ID NUMBERS (COMPANY ID) AS-BUILT INFORMATION LB DC FOREMAN: INCLUDE PHASE TAPPED V01 559162 147300 42"x48"x38" Unistrut HH Matid: 7663001 37.5KVA RF MP 120/240 Matid: 9995528 2 - MINU1SL 6045.1010 BØ V02 559162 147316 42"x48"x38" Unistrut HH Matid: 7663001 50kVA RF MP 120/240 Matid: 9995529 2 - MINU1SL 6045.1010 BØ V03 559164 147338 42"x48"x38" Unistrut HH Matid: 7663001 50kVA RF MP 120/240 Matid: 9995529 1 1 MINU1SR 6045.1010 BØ PRIMARY CABLE & CONDUIT TABLE LOCATION CONDUIT CABLE ASBUILT INFORMATION - FOREMAN COMPLETE FROM TO SIZE (IN)QTY. DESIGN LENGTH (FT) BENDS PULL (LBS) PULL REV (LBS) CABLE SIZE DESIGN LENGTH (FT) PHASE - ID TAG RECORD RECORD PHASE TAPPED & ACTUAL FOOTAGE INSTALLED LUBRICANT (Gal.) 90°45°22°11°A B C MANUFACTURER COMPOUND YEAR NOTES CONDUIT CABLE EST.ACTUAL P01 V01 2 1 130 -1 --67 134 1/0 AL JKT 235 -EJC871 --0.9 V01 V02 2 1 170 ----96 96 1/0 AL JKT 180 -EJC872 --0.7 V02 V03 2 1 230 --2 -125 120 1/0 AL JKT 240 -EJC873 --1.0 2" PVC (FT) & BENDS =530 0 1 2 0 1/0 AL JKT TOTAL (FT) =655 TTL (Gal.) = 2.6 SITE MON IRR 'A' LOT 15 LOT 14 LOT 21 LOT 13 LOT 20 LOT 19 LOT 18 LOT 17 LOT 16 LOT 6LOT 5LOT 4 LOT 11 LOT 3 LOT 10 LOT 2 LOT 9 LOT 1 LOT 8 LOT 7 LOT 12 DEVELOPER RESPONSIBLE FOR CONDUIT/WIRE FROM H1A TO METER LOCATION DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP D. BETTENCOURT 206.445.5958 . C.GESTRING 253.234.6394 1.13.22 C. GESTRING 253.234.6394 1.13.22 A. VASQUEZ .12.14.21 REDT # ( RW-124370 )YELM THE MEADOWS AT MILL POND 1Ø PRIMARY U/G LINE EXTENSION - 21 S/F LOTS P# 22730220600; 700 BLOCK MILL ROAD SE, YELM, WA 98597 PUGET SOUND ENERGY N/A IP 344-60 107061204 105098782 N/A 4 OF 4 THURSTON 344 CIONC QSTHLE 30SE-T17N-R02E 284.044 284.044 1702E120 1702E116 1702E118 YEL-26 COMCAST TED AXTELL . WAVE BROADBAND . . RIGHT OF WAY CAROLYN BANASKY 253.476.6416 . . . ... ... ... NOT TO SCALE NEW CONDUIT DIAGRAM 1. 2. 3. 4. 5. ALL STREET LIGHTING POLES ARE TO BE INSTALLED PER STANDARD 6375.4800 (page #2) IN THE "LINE WORK PRACTICES MANUAL". ALL POLES (WOOD, CONCRETE OR FIBERGLASS) ARE TO BE SET PLUMB AND EMBEDDED TO THE GROUND LINE MARKED ON THE POLE. BACKFILL AROUND POLE WITH 5/8" MINUS GRAVEL AND COMPACT IN 6" LIFTS. (PEA GRAVEL AND NATIVE SOILS ARE NOT ACCEPTABLE.) APPROXIMATELY 1 CU. YD. OF 5/8" MINUS CRUSHED ROCK WILL BE REQUIRED. THE DEVELOPER IS REQUIRED TO SUPPLY AND INSTALL PLASTIC (NON PAPER) STREET LIGHT TUBES (MINIMUM 18" DIAMETER) TO AID IN THE INSTALLATION OF THE STREET LIGHTING POLES. THE DEVELOPER MUST ALSO SUPPLY THE REQUIRED 5/8" MINUS GRAVEL AT EACH STREET LIGHT LOCATION. IN ALL SHOEBOX AND COBRAHEAD INSTALLATIONS, THE LUMINAIRE MUST BE LEVELED. DEVELOPER MUST SUPPLY DURABLE LID/COVER AT EACH STREET LIGHT TUBE. 6. NOT TO SCALE STREET LIGHT TUBE DETAIL Plan View Detail of Street Light Tube Wire Entrance Slot Street Light Tube Field Side Road Side Wire Entrance Slot 45° 45° Position 3" x 6" wire entrance slot 45 degrees left or right from a line perpendicular to road- way through center of tube. Field Side 3" x 6" Wire Entrance Slot 45° 45° Street light tube set 2" below grade. Road Side 18" - 24" Minimum Depending on Pole Type 5'-0" 20" 26" STREET LIGHT CIRCUITRY TABLE - 105099387 SITE #FROM CABLE INFO AS-BUILT REMARKSTYPELFTYPELENGTH FL1 -#6 CIC -- BY INTOLIGHT FL2 -#6 CIC -- BY INTOLIGHT FL3 -#6 CIC -- BY INTOLIGHT FL4 -#6 CIC -- BY INTOLIGHT SL1 -#6 CIC - SL2 -#6 CIC - SL3 -#6 CIC - SL4 -#6 CIC - SL5 -#6 CIC - SL6 -#6 CIC - TOTAL FT =###TOTAL FT = STREET LIGHT TABLE (BY INTOLIGHT) SITE # STATION OFFSET POLE LUMINAIRE TUBE WO # (INTOLIGHT) BILLING SCH.GRID #INTOLIGHT TAG #TYPE ARM MTG HT.WATTS STYLE TUBE LENGTH TUBE DIAMETER SL1 -XXXXX XXXXX ---------- SL2 -XXXXX XXXXX ---------- SL3 -XXXXX XXXXX ---------- SL4 -XXXXX XXXXX ---------- SL5 -XXXXX XXXXX ---------- SL6 -XXXXX XXXXX ---------- SL7 -XXXXX XXXXX ---------- SL8 -XXXXX XXXXX ---------- SL9 -XXXXX XXXXX ---------- SL10 -XXXXX XXXXX ---------- THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) CUST. OWNED ST. LT. CIC #6 SECONDARY 3" PRIMARY 2" CONDUIT LEGEND SECONDARY HH/PEDESTAL TABLE Site Pedestal or Handhole Number of Positions Required Remarks H1A PEDESTAL 5 - SEPL6 6050.1000 H2A PEDESTAL 5 - SEPL6 6050.1000 H3A PEDESTAL 4 - SEPS4 6050.1000 SECONDARY CABLE & CONDUIT TABLE LOCATION CABLE CONDUIT VOLTAGE ASBUILT INFORMATION SIZE LENGTH ASSUMED SIZE LENGTH BENDS DROP FLICKER Foreman - Complete FROM TO (1/O,4/O,350)Design (ft)Lot Corner to Meter (ft)(in)Design (ft)90°45°22°11°(Percent)(Percent)Actual Amount Installed Cable Conduit V01 H1A 350 155 3 85 4 3.3 2.8 V01 LOT 18 4/O 65 60 3 65 1 3.9 3.5 V01 LOT 19 4/O 10 60 3 10 1 3.5 3.0 V01 LOT 20 4/O 10 60 3 10 1 3.5 3.0 V01 LOT 21 4/O 70 60 3 70 1 3.9 3.6 H1A LOT 1 4/O 60 3 4.0 3.4 LABEL YELLOW TAG "MUST BE 4/0 TO MTR" H1A LOT 2 4/O 60 3 4.0 3.4 LABEL YELLOW TAG "MUST BE 4/0 TO MTR" V02 H2A 350 120 3 120 2 3.3 2.0 V02 LOT 3 4/O 85 60 3 15 3 3.6 3.2 V02 LOT 4 4/O 85 60 3 15 2 3.6 3.2 V02 LOT 16 4/O 10 60 3 10 1 3.1 2.4 V02 LOT 17 4/O 10 60 3 10 1 3.1 2.4 H2A LOT 5 4/O 95 60 3 25 2 4.4 3.5 LABEL YELLOW TAG "MUST BE 4/0 TO MTR" H2A LOT 6 4/O 95 60 3 25 3 4.4 3.5 LABEL YELLOW TAG "MUST BE 4/0 TO MTR" H2A LOT 14 4/O 60 3 4.1 3.1 H2A LOT 15 4/O 60 3 4.1 3.1 V03 H3A 350 135 3 135 2 2 3.0 2.1 V03 LOT 10 4/O 80 115 3 80 1 1 3.3 3.1 LABEL YELLOW TAG "MUST BE 4/0 TO MTR" V03 LOT 11 4/O 55 105 3 55 1 1 3.8 3.7 V03 LOT 12 4/O 10 60 3 10 1 2.9 2.4 V03 LOT 13 4/O 10 60 3 10 1 2.9 2.4 H3A LOT 7 4/O 45 60 3 45 1 4.2 3.6 H3A LOT 8 4/O 60 3 3.9 3.2 H3A LOT 9 4/O 75 3 4.1 3.5 4/O UG Triplex (ft) =735 3" PVC & BENDS (ft)=795 29 0 4 0 350 UG Triplex (ft) =410 TOTAL QTS OF GLUE 3.0