105098904 THE VISTA AT MILL PONDssssssssssssssssssssssssssss1+002+003+00LOT 15 LOT 16 LOT 9 LOT 17 LOT 10 LOT 18 LOT 11 LOT 12 LOT 5 LOT 13 LOT 14 LOT 24 LOT 23 LOT 22 LOT 21 LOT 25 LOT 26 LOT 27 LOT 28 LOT 29 TRACT 'A' LOT 6 LOT 1 LOT 2 LOT 3 LOT 4 LOT 7 LOT 8 TRACT 'B' LOT 19 LOT 20 104TH AVE SE MILL RD SE104TH PL SE VISTA RD 1VISTA RD 2BARRY BRIDGES ST SE15510 15501 10518 10440 ABC#2ACSRABC#2ACSRB#4AC S R FUSE @ 65T SW#T86497 REMOVE REMOVE IRR MON ST LT FEEDYEL 26 DEVELOPER RESPONSIBLE FOR CONDUIT/WIRE FROM H1A TO METER LOCATION #2ACSR58'58'20'49'60' R50' R50' FUSE @ 25T SW#T86740 1" = 50' DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP D. BETTENCOURT 206.445.5958 . C. GESTRING 253.234.6394 12.16.21 C.GESTRING 253.234.6394 12.16.21 S. LEWISON .12.1.21 REDT # ( RW-124176 )YELM THE VISTA AT MILL POND 1Ø PRIMARY U/G LINE EXTENSION - 29 S/F LOTS 10447 MILL RD SE, YELM, WA 98597 PUGET SOUND ENERGY N/A IP 344-60 107061294 105098904 1" = 50'2 OF 4 THURSTON 344 CIONC QSTHLE 25SE-T17N-R01E 284.038 284.043 1701E100 1702E116 1701E097 YEL-26 COMCAST TED AXTELL . WAVE BROADBAND . . RIGHT OF WAY CAROLYN BANASKY 253.476.6416 . . . SITE PLAN CIRCUIT LOADING TABLE AS OF EXIST. PEAK LOAD EST. NEW LOAD TOTAL CIRCUIT: A PHASE B PHASE C PHASE YEL-26 06.11.21 260 256 272 N/A 23 N/A 260 279 272 ... ... ... SCHED.SQ. FT. MAX LRC = CIRCUIT FEET ADDED: 1137 17 3,200 115 AMPS THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) LRC: % V. Drop: % Flicker: Sq. Footage: Panel Size: Heat Type: Est. Demand: Units: BUILDING #IRRIGATION N/A N/A TBD N/A 1kW N/A 2.7 @ H1A 2.0 @ H1A Developer Note: The following Fault Current information MUST BE conveyed to the builder of the units: All units may require upgraded house electrical equipment as the fault current at the meter base may exceed 10,000 amps. CUSTOMER OWNED AND INSTALLED SECONDARY WIRE TABLE BLDG.# OF METERS SOURCE # OF RUNS WIRE SIZE REMARKS -1 H1A 1 #1AL IRRIGATION -1 H1A 1 #1AL MONUMENT -1 H1A 1 TBD STREET LIGHTS ALL CUSTOMER-OWNED WIRE MUST BE INSTALLED ACCORDING TO THIS TABLE FAULT CURRENT TABLE 1Ø PM TRANSFORMERS (240/120V) 120V WINDINGS 240V WINDINGS LOCATION SIZE R/X MIN. %Z FAULT CURRENT MIN. %Z FAULT CURRENT V02 75kVA 0.5 2.30 36,200 AMPS 1.80 23,100 AMPS LRC: % V. Drop: % Flicker: Sq. Footage: Panel Size: Heat Type: Est. Demand: Units: BUILDING #MONUMENT N/A N/A TBD N/A 1kW N/A 2.7 @ H1A 2.0 @ H1A LRC: % V. Drop: % Flicker: Sq. Footage: Panel Size: Heat Type: Est. Demand: Units: BUILDING #STREET LIGHTS N/A N/A TBD N/A 1kW N/A 2.7 @ H1A 2.0 @ H1A Oil-Filled Equipment Clearances per PSE Std 0700.1500 If the oil-filled equipment is adjacent to… Clearance Requirement Combustible walls or roof (including stucco).10 FT Combustible walls using a reduced-flammability transformer. Gas service meter relief vent.3 FT Noncombustible walls, soffits, and roofs (including brick, concrete, steel and stone) providing the side of the transformer facing the wall does not have doors. Materials that pass UBC Std. 2-1 or ASTM E136-79 are considered to be noncombustible. 3 FT Generators, customer-owned transformers, fire sprinkler valves, standpipes, and fire hydrants.6 FT Doors, windows, vents, fire escapes, or other building openings.10 FT The water's edge of a swimming pool or any body of water.15 FT Facilities used to dispense or store LP, hazardous liquids, or fuel.20 FT Individual domestic and irrigation wells. Clearance not required on pole mounted transformers (pole placement still applies as stated in 6450.3000), TUT's installed in sealed vaults, 7200V single-phase padmount transformers 50kva or less, and reduced flammability oil. 100 FT SITE SPECIFIC NOTES AT P01 (559125-147280) 1993 CLASS 3 - 45' -INSTALL (1) 2" PRIMARY RISER ON EXISTING STANDOFF BRACKETS -STIRRUP (2254000) -ALUM "H" CONNECTOR (2167000) (RIS2CSS) 6042.1000 -FUSE @ 65T (3412600), TAP 'B' PHASE -INSTALL SWITCH# T86497 -INSTALL 1Ø TERM ON FIBERGLASS ARM W/ LOAD INTERRUPTOR C/O & SURGE ARRESTOR (TSU1L1) 6043.1000 CROSSING CONDUIT TABLE X-ING # LOCATION GAS POWER XING LENGTH ASBUILT LOCATION TYPE OF CROSSING (Feeder, Primary, Secondary, etc.)FROM TO SIZE (IN)TYPE QTY LOCATION SIZE (IN)TYPE QTY X01 LOT 29 LOT 1 2 40 1 S 3 DB120 2 70 ( )' SCL GAS SVC, SECONDARY X02 LOT 26 LOT 4 ----2 DB120 1 70 ( )' NCL PRIMARY 2 40 1 N 3 DB120 2 70 ( )' NCL GAS SVC, SECONDARY X03 LOT 26 LOT 25 4 40 1 E 2 DB120 2 30 ( )' ECL GAS MAIN, PRIMARY X04 LOT 25 LOT 15 4 40 1 E 2 DB120 1 80 ( )' ECL GAS MAIN, PRIMARY X05 LOT 15 LOT 25 2 40 1 E 3 DB120 1 70 ( )' ECL GAS SVC, SECONDARY X06 LOT 13 LOT 5 2 40 1 W 3 DB120 1 70 ( )' WCL GAS SVC, SECONDARY 2" PVC PLUG /CAPS = 8 2" YELLOW SCH 40 PVC = 280 FT 2" DB120 GREY PVC = 210 FT 2" PVC PLUG /CAPS = 8 4" PVC PLUG /CAPS = 4 4" YELLOW SCH 40 PVC = 110 FT 3" DB120 GREY PVC = 420 FT 3" PVC PLUG /CAPS = 12 DEDICATED FACILITIES (105098904) for Dedicated Stub Locations & RF Transformers SITE SPAN ADDITIONAL REMARKS LABOR UNITS #FROM TO FOOTAGE -V01 LOT 2 55 DED. CONDUIT & WIRE 2-36, 2-54A -V03 LOT 5 25 DED. CONDUIT & WIRE 2-36, 2-54A -V03 LOT 9 15 DED. CONDUIT & WIRE 2-36, 2-54A -V03 LOT 11 40 DED. CONDUIT & WIRE 2-36, 2-54A -V02 LOT 14 50 DED. CONDUIT & WIRE 2-36, 2-54A -V02 LOT 18 25 DED. CONDUIT & WIRE 2-36, 2-54A -H2B LOT 20 35 DED. CONDUIT & WIRE 2-36, 2-54A -H2B LOT 21 15 DED. CONDUIT & WIRE 2-36, 2-54A V01 - V03 ---REDUCED FLAMMABILITY - TOTAL FT=260 →SEE PSE HANDBOOKS← SEE 1218 (SF),1220 (MF), 6080, FOR TRENCH SEE 3061, 2809 LABOR UNITS - - - - - - - - - - - 2-24 2-26 - - - - - - - - 2-26 - - - - - - - - - - - - - - - - AT P02 (559131-147256) 2013 CLASS 2 - 45' -REMOVE POLE & ALL PSE EQUIPMENT - - - - -REMOVE 15kVA OH 120/240V TRF & C/O AT P03 (559133-147241) 2013 CLASS 3 - 45' - - - - - -REMOVE POLE & ALL PSE EQUIPMENT AT P04 (559138-147233 ) -INSTALL (1) 2" PRIMARY RISER -STIRRUP (2254000) -ALUM "H" CONNECTOR (2167000) (RIS2CSS) 6042.1000 -FUSE @ xx (3412600), TAP 'B' PHASE -INSTALL SWITCH# T86740 -INSTALL NEW 45' CLASS 3 POLE (PD453) -INSTALL 1Ø TERM ON FIBERGLASS ARM W/ LOAD INTERRUPTOR C/O & SURGE ARRESTOR (TSU1L1) 6043.1000 -DEEP SET POLE +1' REQUIRED FOR CROSSWIND -