UPDATED WORK SKETCH 105098151 BERRY VALLEYT BLDG 1 8 UNITS ~1000 SQ.FT. BLDG 2 24 UNITS ~1000 SQ.FT. BLDG 3 24 UNITS ~1000 SQ.FT. BLDG 4 24 UNITS ~1000 SQ.FT. TAHOMA BOULEVARD SE BE R R Y V A L L E Y A V E N U E EX: 3-6" EX: 4-4" EX: 1-4" (4) 350 (4) 350 (4) 350 (4) 350 DEVELOPER RESPONSIBLE FOR CONDUIT/WIRE FROM VAULT TO METER LOCATION (TYPICAL) #4ACSR CC#4ACSR FUT: 1-4"ROAD AROAD CROAD BROAD BROAD B ROAD B WYNDSTONE CONDOS 105099121 56' 26'26'26'26'26'26' 26'91''A' 'B' 'C' 'D' 'E' T FEEDYEL 25 1" = 50' DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP D. BETTENCOURT 206.445.5958 . E. ORTIZ .02.01.22 N/A .N/A E. ORTIZ .02.01.22 REDT # ( RW-123753 )YELM BERRY VALLEY 2Ø PRIMARY U/G LINE EXTENSION - 4 M/F BLDGS, 80 UNITS 15035 BERRY VALLEY ROAD, YELM, WA 98597 PUGET SOUND ENERGY N/A N/A N/A 105098151 1" = 50'2 OF 4 THURSTON N/A N/A QSTHLE 24SE-T17N-R01E N/A N/A 1701E096 1702E116 1701E096 YEL-25 COMCAST TED AXTELL 253.878.2794 TELEPHONE COMM TBD COMM TEL TBD RIGHT OF WAY CAROLYN BANASKY 253.476.6416 . . . SITE PLAN CIRCUIT LOADING TABLE AS OF EXIST. PEAK LOAD EST. NEW LOAD TOTAL CIRCUIT: A PHASE B PHASE C PHASE YEL-25 06.11.21 301 310 317 25 17 0 326 327 317 ... ... ... SCHED.SQ. FT. MAX LRC = CIRCUIT FEET ADDED: 1,720 17 1,000 65 AMPS THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773)BREAKLINE ~505 FTDEVELOPER TO COORDINATE WITH PSE PROJECT MANGER & SERVICE PROVIDER PRIOR TO EXCAVATING WITHIN 3' OF LOCATE MARKS OF PSE ENERGIZED FACILITIES LRC: % V. Drop: % Flicker: Sq. Footage: Panel Size: Heat Type: Est. Demand: Units: BUILDING #1 8 + HP 1,000 200A ELEC 43KW 65 2.2 @ V04 1.0 @ V04 LRC: % V. Drop: % Flicker: Sq. Footage: Panel Size: Heat Type: Est. Demand: Units: BUILDING #2 24 + HP 1,000 200A ELEC 99KW 65 1.6 @ V03 0.3 @ V03 LRC: % V. Drop: % Flicker: Sq. Footage: Panel Size: Heat Type: Est. Demand: Units: BUILDING #3 24 + HP 1,000 200A ELEC 99KW 65 1.6 @ V02 0.3 @ V02 LRC: % V. Drop: % Flicker: Sq. Footage: Panel Size: Heat Type: Est. Demand: Units: BUILDING #4 24 + HP 1,000 200A ELEC 99KW 65 1.6 @ V01 0.3 @ V01 Developer Note: The following Fault Current information MUST BE conveyed to the builder of the units: All units may require upgraded house electrical equipment as the fault current at the meter base may exceed 10,000 amps. FAULT CURRENT TABLE 1Ø PM TRANSFORMERS (240/120V) 120V WINDINGS 240V WINDINGS LOCATION SIZE R/X MIN. %Z FAULT CURRENT MIN. %Z FAULT CURRENT V01-V03 100kVA 0.5 2.43 57,300 AMPS 1.90 36,600 AMPS V04 37.5kVA 0.6 2.23 18,700 AMPS 1.7 12,300 AMPS CUSTOMER OWNED AND INSTALLED SECONDARY WIRE TABLE BLDG.# OF METERS SOURCE # OF RUNS WIRE SIZE REMARKS 1 9 V04 4 350 - 2 25 V03 4 350 - 3 25 V02 4 350 - 4 25 V01 4 350 - ALL CUSTOMER-OWNED WIRE MUST BE INSTALLED ACCORDING TO THIS TABLE M A T C H L I N E A - A ( S E E B E L O W R I G H T ) M A T C H L I N E A - A ( S E E A B O V E L E F T ) CROSSING CONDUIT TABLE X-ING # LOCATION POWER XING LENGTH ASBUILT LOCATION TYPE OF CROSSING (Feeder, Primary, Secondary, etc.)FROM TO SIZE (IN)TYPE QTY X01 'A''B'4 DB120 1 65 ( )'SCL PRIMARY X02 'B''C'2 DB120 2 135 ( )'ECL PRIMARY X03 'D''E'2 DB120 1 75 ( )'ECL PRIMARY 2" DB120 GREY PVC = 345 FT 2" PVC PLUG /CAPS = 6 4" DB120 GREY PVC = 65 FT 4" PVC PLUG /CAPS = 2