Civil Site Development PlansCRYSTAL SPRINGS STREET NW26
18
TRACT A
17
12
16
141113
20 19
9
15
23
6
1
2
3
4
10
7
8
25
21
24
TRACT B
5
29
27
CRYSTAL SPRINGS ST NWWOODLAND CT SE
ROAD A
ROAD BROAD C
22
30
APN
22719210403
28
1
2
3
4
TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
Know what's below.
before you dig.Call
R
27
STKTDSMTL
4/6/2022
PERMIT SET
2210633.10
P.O.BOX 73790
PUYALLUP, WA 98373-0790
EVAN MANN
COPPER RIDGE, LLC
CRYSTAL SPRINGS
A PORTION OF THE NE 1/4 OF THE NW 1/4 OF SEC. 19, TWN. 17 N., RGE. 02 E. W.M.
CITY OF YELM, THURSTON COUNTY, WASHINGTON.
CRYSTAL SPRINGS
APPLICATION #
DATE: April 6, 2022 FILENAME: Q:\2021\2210633\10_CIV\CAD\_FINAL DESIGN\_2210633-SH-COVR.dwg
C0.1
1
COVER SHEET
N
GRAPHIC SCALE
0 50 100
1" = 50 FEET
25
AHBL ENGINEERS, PLANNERS, &
SURVEYORS
2215 NORTH 30TH STREET, SUITE 300
TACOMA, WA 98403
PH. (253) 383-2422
FAX (253) 383-2572
CONTACT: MATT WEBER, P.E.
COPPER RIDGE, LLC
P.O.BOX 73790
PUYALLUP, WA 98403
CONTACT: EVAN MANN
AHBL ENGINEERS, PLANNERS, &
SURVEYORS
2215 NORTH 30TH STREET, SUITE 300
TACOMA, WA 98403
PH. (253) 383-2422
FAX (253) 383-2572
CONTACT: DAVE FOLLANSBEE, PLS.
IF WORKERS ENTER ANY TRENCH OR OTHER EXCAVATION FOUR OR MORE
FEET IN DEPTH THAT DOES NOT MEET THE OPEN PIT REQUIREMENTS OF
WSDOT SECTION 2-09.3(3)B, IT SHALL BE SHORED AND CRIBBED. THE
CONTRACTOR ALONE SHALL BE RESPONSIBLE FOR WORKER SAFETY AND
AHBL ASSUMES NO RESPONSIBILITY. ALL TRENCH SAFETY SYSTEMS SHALL
MEET THE REQUIREMENTS OF THE WASHINGTON INDUSTRIAL SAFETY AND
HEALTH ACT, CHAPTER 49.17 RCW.
THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE APPROXIMATE
ONLY AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR ITS
REPRESENTATIVE. THE CONTRACTOR SHALL DETERMINE THE EXACT
LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK AND
AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES THAT
HAPPEN DUE TO THE CONTRACTOR'S FAILURE TO LOCATE EXACTLY AND
PRESERVE ANY AND ALL UNDERGROUND UTILITIES. AHBL ASSUMES NO
LIABILITY FOR THE LOCATION OF UNDERGROUND UTILITIES.
IMPORTED FILL MATERIAL SHALL NOT CONTAIN PETROLEUM PRODUCTS, OR
SUBSTANCES WHICH ARE HAZARDOUS, DANGEROUS, TOXIC, OR WHICH
OTHERWISE VIOLATE ANY STATE, FEDERAL, OR LOCAL LAW, ORDINANCE,
CODE, REGULATION, RULE, ORDER, OR STANDARD.
TRENCH NOTE
UTILITY NOTE
FILL SPECIFICATION
LEGAL DESCRIPTION
BASIS OF BEARING
VERTICAL DATUM
DEVELOPER
CIVIL ENGINEER
SURVEYOR
CUT = 3,000 CU. YDS
FILL = 3,050 CU. YDS
NET = 50 CU. YDS IMPORT
NOTE:
THE ABOVE QUANTITIES ARE ESTIMATES ONLY INTENDED FOR
THE PERMITTING PROCESS. DO NOT USE FOR BID PURPOSES.
THE QUANTITIES DO NOT HAVE STRIPPING, COMPACTION, OR
CUT OR FILL ADJUSTMENT FACTORS APPLIED TO THEM, NOR
DO THEY ACCOUNT FOR ROADWAY SECTION.
NO WETLANDS HAVE BEEN DELINEATED ON-SITE OR IMMEDIATELY ADJACENT
TO THE PROJECT SITE.
PROJECT SITE
SCALE 1"=50'
WETLAND DELINEATION
EARTHWORK QUANTITIES
EXISTING DESCRIPTION PROPOSED
CEMENT CONC. PAVEMENT
NATURAL GAS LINE
CONIFER TREE
DECIDUOUS TREE
ASPHALT CONC. PAVEMENT
STANDARD DUTY PAVING
SANITARY SEWER LINE
STORM DRAIN LINE
POWER/TELE. POLE
CHAIN LINK FENCE
FIRE SERVICE
WATER LINE
CONTOURS
WIRE FENCE
WOOD FENCE
WATER METER
WATER VALVE
SIGN
HYDRANT
STORM DRAIN MH
SANITARY SEWER MH
CATCH BASIN
TELEPHONE MH
TELEPHONE RISER
GUY WIRE
LIGHT
W
D
ELEV
D
W
SS
F
ELEV
G
LEGEND
PER CHICAGO TITLE INSURANCE COMPANY ORDER NO.
210046238
PARCEL 3 OF SHORT SUBDIVISION NO. SS-8036, AS RECORDED
NOVEMBER 26, 1991 UNDER AUDITOR'S FILE NO. 9111260271.
IN THURSTON COUNTY, WASHINGTON
NAVD 1988 VERTICAL DATUM ON ORTHOMETRICALLY
CORRECTED GPS OBSERVATIONS USING WSRN AND GEOID
2012A.
NAD 1983/11
WASHINGTON STATE PLANE SOUTH PROJECTION, BASED ON GPS
OBSERVATIONS USING WSRN AND GEOID 2012A. UNITS OF
MEASUREMENT ARE US SURVEY FEET.NW RHOTON RDCANALRD SECRYSTAL SPRINGS ST SWCULLENS RD SEC
O
A
T
E
S
A
V
E
NW
RAILWAY RD SE
510
VIEW DR NW
WOODLAND CT SE
SITE
VICINITY MAP
SCALE: 1" = 1,320' (1/4 MILE)
SITE DATA
PARCEL NUMBER: 22719210403
ADDRESS: 714 CRYSTAL SPRINGS ROAD
YELM, WA 98597
SITE AREA:213,366 SF (4.89 AC)
EXISTING ZONING:R-6, RESIDENTIAL
SHEET INDEX
Sheet Number Sheet Title
C0.1 COVER SHEET
C1.1 EXISTING CONDITIONS PLAN
C1.2 PLAT MAP
C2.1 DEMOLITION AND TESC PLAN
C2.2 TESC NOTES AND DETAILS
C2.3 TESC NOTES AND DETAILS
C3.1 ROAD A PLAN & PROFILE
C3.2 ROAD B PLAN & PROFILE
C3.3 ROAD C PLAN AND PROFILE
C3.4 TRACT B PLAN AND PROFILE
C3.5 INTERSECTION DETAILS
C3.6 CUL-DE-SAC DETAIL
C3.7 ROAD NOTES AND DETAILS
C3.8 ROAD NOTES AND DETAILS
C3.9 ROAD NOTES AND DETAILS
C4.1 DRAINAGE AND STORM PLAN
C4.2 STORM NOTES AND DETAILS
C4.3 STORM NOTES AND DETAILS
C4.4 STORM NOTES AND DETAILS
C4.5 ON LOT INFILTRATION
C5.1 ROAD A & TRACT B WATER PLAN AND PROFILE
C5.2 ROAD B WATER PLAN AND PROFILE
C5.3 WATER NOTES AND DETAILS
C5.4 WATER NOTES AND DETAILS
C6.1 ROAD A & TRACT B SEWER PLAN AND PROFILE
C6.2 ROAD B SEWER PLAN AND PROFILE
C6.3 SEWER NOTES AND DETAILS
04/08/2022
CRYSTAL SPRINGS ST NWWOODLAND CT SE
BUILDING SETBACKS (TYP.)
22719210404
CITY OF YELM
22719210403
MCLENNAN
JERRY & MELISSA
43390102000
ALMORA
JESUS & LISA
43390100000
CRYSTAL SPRINGS ESTATES HOMEOWNERS
43390100000
CRYSTAL SPRINGS ESTATES HOMEOWNERS
43390101900
BUSSELL, JOSEPH
43390101800
RODRIGUEZ, MARIA
43390101700
BARLOW
BRIDGET M & CINDY R
43390101600
NORIEGA
DAVID E & SAVANNAH
43390101500
STOKLEY, TIMOTHY K
43390101400
STOKLEY, TIMOTHY K
43390100100
SELL
CORTNEY D & RYNE A43390100200
CLAY, GARY
43390100300
SMITH, DAEDRA D
43390100400
FAIRCHILD, JOE
22719240101
YELM COMMUNITY SERVICES
22719240101
YELM COMMUNITY SERVICES
1
2
3
4
TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
Know what's below.
before you dig.Call
R
27
STKTDSMTL
4/6/2022
PERMIT SET
2210633.10
P.O.BOX 73790
PUYALLUP, WA 98373-0790
EVAN MANN
COPPER RIDGE, LLC
CRYSTAL SPRINGS
A PORTION OF THE NE 1/4 OF THE NW 1/4 OF SEC. 19, TWN. 17 N., RGE. 02 E. W.M.
CITY OF YELM, THURSTON COUNTY, WASHINGTON.
CRYSTAL SPRINGS
APPLICATION #
DATE: April 6, 2022 FILENAME: Q:\2021\2210633\10_CIV\CAD\_FINAL DESIGN\_2210633-SH-EX-COND.dwg
C1.1
2
EXISTING
CONDITIONS
PLAN
N
GRAPHIC SCALE
0 40 80
1" = 40 FEET
20
04/08/2022
3736
S.F.
26
4130
S.F.
18
11036
S.F.
TRACT A
3823
S.F.
17
4987
S.F.
12
3995
S.F.
164939
S.F.
145470
S.F.
11
4963
S.F.
13
4010
S.F.
20
4439
S.F.
19
3600
S.F.
9
4511
S.F.
15
3706
S.F.
23
3600
S.F.
6
5023
S.F.
1
3600
S.F.
2
3600
S.F.
3
3600
S.F.
4
5466
S.F.
10
3600
S.F.
7
3600
S.F.
8
4717
S.F.
25
5421
S.F.
21
3652
S.F.
24
6054
S.F.
TRACT B3600
S.F.
5
4209
S.F.
29
3680
S.F.
27
37.87'3 2 .24'69.23'55.00'90.00'
90.00'40.00'40.00'90.00'40.00'40.00'90.00'40.00'40.00'90.00'40.00'40.00'90.00'40.00'40.00'90.00'40.00'40.00'90.00'40.00'40.00'90.00'40.00'40.00'
70.55'
30.
8
9'40.97'62.81'124.98'42.01'125.70'45.30'40.00'124.37'40.00'123.77'40.00'
40.00'
40.00'123.16'40.00'
19.58'18.60'20.90'102.04'40.00'
40.23'97.74'40.00'
40.23'93.43'40.00'
46.04'88.51'45.00'
23.1
9
'
42.32'42.32'31.94 '42.74'40.00'40.00'52.60'36.00'148.98'30.59'
24.22'
40.00'565.06'40.00'373.36'58.02'50.00'0.88'6 8.03'42.27'25.32
'40.00'2.02'96.64'147.22'40.00'38.59'29.06'94.74'
93.32'
91.99'1.44'40.03'90.59'52.64'88.75'92.70'40.02'91.31'40.00'104.52'40.02'
40.00'103.12'40.02'
78.0
5'
25.00'21.21'5.00'
47.47'CRYSTAL SPRINGS ST NWWOODLAND CT SE
0+00 1+00 2+00 3+00 3+81
11+0012+0013+0014+0020+00 21+00 22+00 23+00 24+00 25+00 25+65
ROAD A
ROAD BROAD C
17.00'
23.00'
31.50'
26.50'
31.50'
26.50'
3761
S.F.
22
40.00'40.03'R50.00'
BUILDING SETBACKS (TYP.)
BUILDING
SETBACKS (TYP.)
40.00'
58.00'
10.00' UTILITY EASEMENT (TYP.)
10.00' UTILITY EASEMENT (TYP.)
22719210404
CITY OF YELM
4153
S.F.
30
105.91'95.31'19.8
7'
24.16'
22719210403
MCLENNAN
JERRY & MELISSA
43390102000
ALMORA
JESUS & LISA
43390100000
CRYSTAL SPRINGS ESTATES HOMEOWNERS
43390100000
CRYSTAL SPRINGS ESTATES HOMEOWNERS
43390101900
BUSSELL, JOSEPH
43390101800
RODRIGUEZ, MARIA
43390101700
BARLOW
BRIDGET M & CINDY R
43390101600
NORIEGA
DAVID E & SAVANNAH
43390101500
STOKLEY, TIMOTHY K
43390101400
STOKLEY, TIMOTHY K
43390100100
SELL
CORTNEY D & RYNE A43390100200
CLAY, GARY
43390100300
SMITH, DAEDRA D
43390100400
FAIRCHILD, JOE
22719240101
YELM COMMUNITY SERVICES
22719240101
YELM COMMUNITY SERVICES
22719210900
PADGETT, VERN L
22719210600
ARNOLD, RICHARD J & MARIA C
22719210204
TIETJEN, MATTHEW R & JENNIFER M
4170
S.F.
28
N88° 44' 20"W
521.01'
N88° 44' 20"W
73.98'S1° 06' 14"E489.10'S89° 36' 30"E
209.37'
S89° 36' 30"E
116.54'
N88° 53' 46"E
55.33'
58.00'
1
2
3
4
TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
Know what's below.
before you dig.Call
R
27
STKTDSMTL
4/6/2022
PERMIT SET
2210633.10
P.O.BOX 73790
PUYALLUP, WA 98373-0790
EVAN MANN
COPPER RIDGE, LLC
CRYSTAL SPRINGS
A PORTION OF THE NE 1/4 OF THE NW 1/4 OF SEC. 19, TWN. 17 N., RGE. 02 E. W.M.
CITY OF YELM, THURSTON COUNTY, WASHINGTON.
CRYSTAL SPRINGS
APPLICATION #
DATE: April 6, 2022 FILENAME: Q:\2021\2210633\10_CIV\CAD\_FINAL DESIGN\_2210633-SH-PLAT.dwg
C1.2
3
PLAT MAP
N
GRAPHIC SCALE
0 40 80
1" = 40 FEET
20
STATISTICAL BREAKDOWN
ITEM DESCRIPTION OR AREA
SQUARE FEET ACRES
SITE AREA 213,366
CRITICAL AREAS
PROPOSED ONSITE ROAD ROW
GROSS DEVELOPMENT AREA
EXISTING & PROPOSED ZONING:
0
70,515
213,366
R-6, RESIDENTIAL
MAXIMUM DENSITY (6 DU/ACRE)
TOTAL NO. OF LOTS PROPOSED (SINGLE FAMILY)
LARGEST LOT AREA (LOT 21)
SMALLEST LOT AREA (LOTS 2, 3, 4, 5, 6, 7, 8, AND 9)
AVERAGE LOT AREA
TOTAL IMPERVIOUS SURFACE (57.10%)
ROAD
ROOF AREA (1,500 SF x 8 UNITS, 2,500 SF x 22 UNITS)
4.89
0.00
30
1.61
4.89
29.34 (USE 30)
5,421
3,600
0.12
0.08
4,229 0.09
0.91
15,000 0.34
121,843 2.79
39,843
67,000 1.53
TRACT IDENTIFICATION
SQUARE FEET ACRES
11,036
6,054
0.25
0.14
ITEM
TRACT 'B' - SHARED ACCESS FACILITY
TRACT 'A' - OPEN SPACE/STORM
DRIVEWAYS (500 SF x 30 UNITS)
LOT SETBACKS - SINGLE FAMILY
FRONT YARD 15 FT
SIDE YARD 5 FT
15 FT (CORNER LOT)
REAR YARD 25 FT
OPEN SPACE 11,036 0.25
CONSTRUCTION CENTERLINE (TYP)
04/08/2022
CRYSTAL SPRINGS STREET NWREMOVE
EXISTING
UTILITIES
REMOVE
EXISTING
UTILITY
REMOVE
FENCE
REMOVE
STRUCTURE
(TYP)
REMOVE
FENCE
REMOVE TREE
(TYP)
REMOVE POLE BARN
REMOVE GRAVEL
DRIVEWAY
USE EXISTING PAVED DRIVEWAY
APPROACH AS STABILIZE CONSTRUCTION
ENTRANCE. LIMIT TRUCK INGRESS/EGRESS
TO THIS LOCATION
336
337
338
336336337338338337337335334337338338338338337
USE FUTURE INFILTRATION FACILITY FOOTPRINT
AS TEMPORARY INFILTRATION SEDIMENT TRAP.
BOTTOM ELEV: 333.00 MIN BOTTOM AREA: 260 SF.
PROVIDE 6' WIDE EMERGENCY SPILLWAY AT ELEV: 337.00
DO NOT EXCAVATE OR DISTURB NATIVE SOILS WITHIN
2FT OF THE PERMANENT FACILITY BOTTOM (326.53)
CD
ID
NEAT SAWCUT
LINE
FUTURE INFILTRATION
FACILITY LIMITS. LIMIT
HEAVY EQUIPMENT
ACTIVITY IN THIS AREA
REMOVE
STRUCTURE
REMOVE
RESIDENCE
REMOVE HOT TUB3393393383373
3
6 337338339339338338
337
338
1
2
3
4
TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
Know what's below.
before you dig.Call
R
27
STKTDSMTL
4/6/2022
PERMIT SET
2210633.10
P.O.BOX 73790
PUYALLUP, WA 98373-0790
EVAN MANN
COPPER RIDGE, LLC
CRYSTAL SPRINGS
A PORTION OF THE NE 1/4 OF THE NW 1/4 OF SEC. 19, TWN. 17 N., RGE. 02 E. W.M.
CITY OF YELM, THURSTON COUNTY, WASHINGTON.
CRYSTAL SPRINGS
APPLICATION #
N
GRAPHIC SCALE
0 40 80
1" = 40 FEET
20
TESC AND DEMO LEGEND
INLET PROTECTION
CLEARING LIMITS
SILT FENCE
INTERCEPTOR DITCH
RIP-RAP PROTECTION
4"x6" SPALLS
REMOVE EXISTING FENCE
EXISTING GRADE CONTOUR
ROCK CHECK DAM
EXISTING TREE TO BE REMOVED
SF
CL
IP
CE
CONSTRUCTION SEQUENCE
1.ARRANGE AND ATTEND PRE-CONSTRUCTION CONFERENCE WITH THE CITY
OF YELM AND CONFIRM REQUIRED INSPECTIONS.
2.STAKE CLEARING AND GRUBBING LIMITS.
3.INSTALL PERIMETER CONTROLS INCLUDING FILTER FABRIC FENCE, OFFSITE
INLET PROTECTION, AND CONSTRUCTION ENTRANCE.
4.FLAG INFILTRATION AREA TO LIMIT COMPACTION AND SEDIMENT LADEN
RUNOFF FROM THIS AREA.
5.INSTALL/IMPLEMENT EROSION CONTROL BMPS.
6.CONSTRUCT TEMPORARY SEDIMENT CONTROL POND PER PLAN.
7.PROVIDE SITE DEMOLITION AND ABANDON/DECOMISSION WELL AND SEPTIC
TANK PER HEALTH DEPARTMENT STANDARDS.
8.CLEAR AND GRUB SITE AS NECESSARY TO INSTALL SITE IMPROVEMENTS.
DURING WET SEASON, DO NOT CLEAR ANY MORE AREA THAN CAN BE
STABILIZED, PER THE GRADING AND EROSION CONTROL PLAN, IN A GIVEN
WORKDAY. DO NOT COMPACT INFILTRATION AREAS.
9.GRADE SITE PER GRADING PLAN.
10.INSTALL STORM SYSTEM PER PLANS. INSTALL INLET PROTECTION FOR NEW
CATCH BASINS.
11.INSTALL FORCE MAIN AND STEP SYSTEM TANKS.
12.INSTALL WATER MAIN AND FIRE SUPPRESSION LINES.
13.CONSTRUCT DRIVE AREAS.
14.INSTALL INFILTRATION TRENCH & PERKFILTER VAULT. DO NOT PLACE
INFILTRATION TRENCH ON LINE UNTIL THE SITE IS FULLY STABILIZED.
15.STABILIZE UNPAVED AREAS OF THE SITE BY HYDRO-SEEDING OR OTHER
APPROPRIATE METHODS PER THE EROSION CONTROL NOTES.
16.ONCE THE SITE HAS BEEN FULLY STABILIZED PLACE INFILTRATION
FACILITIES ONLINE.
17.PAVE ONSITE DRIVE AREAS.
18.REMOVE ALL TEMPORARY EROSION CONTROL FACILITIES AFTER SITE HAS
BEEN PERMANENTLY STABILIZED AND APPROVED BY THE CITY.
19.CLEAN STORM DRAINAGE SYSTEM PIPING AND CATCH BASINS.
20.CALL FOR FINAL INSPECTION(S).
CD
ID
DATE: April 6, 2022 FILENAME: Q:\2021\2210633\10_CIV\CAD\_FINAL DESIGN\_2210633-SH-TESC.dwg
C2.1
4
DEMOLITION AND
TESC PLAN
REMOVE TREE
(TYP)
REMOVE ROCK PILE
DECOMMISION EXISTING WELL ACCORDING TO WADOH
AND PIERCE COUNTY REQUIRMENTS
REMOVE
STRUCTURE
CL
(TYP)
CL
(TYP)
REMOVE
EXISTING
POND
REMOVE
DEBRIS
PILE
SF
(TYP)
TEMPORARY 12" CPEP CULVERT
RR
IP
(TYP)
(TYP)
(TYP)
FUTURE PAVING
LIMITS (TYP)
1
C2.2
1
C2.3
EXISTING TOPSOIL SHALL BE STRIPPED AND STOCKPILED ON-SITE.
STOCKPILE AND COVER SOIL WITH WEED BARRIER MATERIAL THAT SHEDS MOISTURE YET
ALLOWS AIR TRANSMISSION, IN APPROVED LOCATION, PRIOR TO GRADING. REPLACE
STOCKPILED TOPSOIL PRIOR TO PLANTING.
IF PLACED TOPSOIL PLUS COMPOST OR OTHER ORGANIC MATERIAL WILL AMOUNT TO LESS
THAN 12 INCHES: SCARIFY OR TILL SUBGRADE TO DEPTH NEEDED TO ACHIEVE 12 INCHES
OF LOOSENED SOIL AFTER TOPSOIL AND AMENDMENT ARE PLACED. ENTIRE SURFACE
SHOULD BE DISTURBED BY SCARIFICATION. DO NOT SCARIFY WITHIN DRIP LINE OF EXISTING
TREES TO BE RETAINED.
WITHIN STORMWATER DRAINAGE SYSTEM LOCATIONS OR LANDSCAPED AREAS (EXCEPT
BIO-RETENTION AREAS) (10 PERCENT ORGANIC CONTENT) –
PLACE AND ROTOTILL 3 INCHES OF COMPOSTED MATERIAL INTO 5 INCHES OF REPLACED
SOIL (A TOTAL DEPTH OF ABOUT 9.5 INCHES, FOR A SETTLED DEPTH OF 8 INCHES).
SUBSOILS BELOW THIS LAYER SHOULD BE SCARIFIED AT LEAST 4 INCHES, FOR A FINISHED
MINIMUM DEPTH OF 12 INCHES OF UNCOMPACTED SOIL. RAKE BEDS TO SMOOTH AND
REMOVE ROCKS LARGER THAN 2 INCHES IN DIAMETER. MULCH AREAS WITH 2 INCHES OF
ORGANIC MULCH OR STOCKPILED DUFF.
WITHIN LAWN AREAS (5 PERCENT ORGANIC CONTENT) –
PLACE AND ROTOTILL 1.75 INCHES OF COMPOSTED MATERIAL INTO 6.25 INCHES OF
REPLACED SOIL (A TOTAL AMENDED DEPTH OF ABOUT 9.5 INCHES, FOR A SETTLED DEPTH
OF 8 INCHES). SUBSOILS BELOW THIS LAYER SHOULD BE SCARIFIED AT LEAST 4 INCHES,
FOR A FINISHED MINIMUM DEPTH OF 12 INCHES OF UNCOMPACTED SOIL. WATER OR ROLL
TO COMPACT SOIL TO 85 PERCENT OF MAXIMUM. RAKE TO LEVEL, AND REMOVE SURFACE
WOODY DEBRIS AND ROCKS LARGER THAN 1 INCH IN DIAMETER.
POST CONSTRUCTION SOIL QUAILIITY AND DEPTH
2
C2.2
2
C2.3
6
C2.2
FUTURE PAVING
LIMITS (TYP)
SF
SF
4
C2.2
PROTECT FUTURE INFILTRATION FACILITY
MARK WITH HIGH VISIBILITY FENCE.
04/08/2022
1
2
3
4
TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
Know what's below.
before you dig.Call
R
27
STKTDSMTL
4/6/2022
PERMIT SET
2210633.10
P.O.BOX 73790
PUYALLUP, WA 98373-0790
EVAN MANN
COPPER RIDGE, LLC
CRYSTAL SPRINGS
A PORTION OF THE NE 1/4 OF THE NW 1/4 OF SEC. 19, TWN. 17 N., RGE. 02 E. W.M.
CITY OF YELM, THURSTON COUNTY, WASHINGTON.
CRYSTAL SPRINGS
APPLICATION #
CHECK DAM
20 5
10 10
6 15
5 20
4 25
2 50
100
%
1
SPACING (FT.)
DITCH SLOPE
CHECK DAM SPACING
A AND B ARE OF EQUAL ELEVATION
L = THE DISTANCE SUCH THAT POINTS
2:1 SLOPES
3:
1
L
A
TOP OF DITCH
B3:12"-4" ROCK
24" MIN.
BOTTOM AND SIDES OF THE DITCH
ROCK MUST COMPLETELY COVER THE
6" MIN.
4"-8" QUARRY SPALLS
GEOTEXTILE
12" MIN. THICKNESS
EXIST
I
N
G
R
O
A
D
R = 25' MIN.
INGRESS/EGRESS AREA
PROVIDE FULL WIDTH OF
20'
MI
N.
RUNOFF DRAINS OFF THE PAD
ENTRANCE BE CROWNED SO THAT
IT IS RECOMMENDED THAT THE100'
1.QUARRY SPALLS (OR HOG FUEL) SHALL BE ADDED IF THE PAD IS NO LONGER IN ACCORDANCE WITH THE
SPECIFICATIONS.
2.IF THE ENTRANCE IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT, THEN
ALTERNATIVE MEASURES TO KEEP THE STREETS FREE OF SEDIMENT SHALL BE USED. THIS MAY INCLUDE
STREET SWEEPING, AN INCREASE IN THE DIMENSIONS OF THE ENTRANCE, OR THE INSTALLATION OF A
WHEEL WASH. IF WASHING IS USED, IT SHALL BE DONE ON AN AREA COVERED WITH CRUSHED ROCK, AND
WASH WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND.
3.ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING. THE
SEDIMENT COLLECTED BY SWEEPING SHALL BE REMOVED OR STABILIZED ON-SITE. THE PAVEMENT SHALL
NOT BE CLEANED BY WASHING DOWN THE STREET, EXCEPT WHEN SWEEPING IS INEFFECTIVE AND THERE IS
A THREAT TO PUBLIC SAFETY. IF IT IS NECESSARY TO WASH THE STREETS, THE CONSTRUCTION OF A
SMALL SUMP SHALL BE CONSIDERED. THE SEDIMENT WOULD THEN BE WASHED INTO THE SUMP.
4.ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAD AND END UP ON THE ROADWAY SHALL BE
REMOVED IMMEDIATELY.
5.IF VEHICLES ARE ENTERING OR EXITING THE SITE AT POINTS OTHER THAN THE CONSTRUCTION
ENTRANCE(S), FENCING SHALL BE INSTALLED TO CONTROL TRAFFIC.
MAINTENANCE STANDARDS
PROVIDE DIP CULVERT
FOR TEMPORARY
CONTROL OF DRAINAGE.
NOTES:
1.FILTERS SHALL BE i NSPECTED AFTER EACH STORM EVENT AND
CLEANED OR REPLACED WHEN 1/3 FULL.
2.INSTALL INLET PROTECTION IN ALL NEW STORM STRUCTURES
THAT WILL COLLECT STORMWATER AS THEY ARE INSTALLED.
ADAPTOR SKIRT RETRIEVAL STRAP
OVERFLOW (TO
BYPASS PEAK
STORM VOLUMES)
EXISTING CATCH BASIN
SEDIMENT ACCUMULATION
GEOTEXTILE
FABRIC 24"36"48"
DATE: April 6, 2022 FILENAME: Q:\2021\2210633\10_CIV\CAD\_FINAL DESIGN\_2210633-SH-TESC.dwg
C2.2
5
TESC NOTES AND
DETAILS
1 NOT TO SCALE
INLET PROTECTION
4 NOT TO SCALE
INFILTRATION SEDIMENT TRAP
2 NOT TO SCALE
GRAVEL CHECK DAM 3 NOT TO SCALE
EMERGENCY OVERFLOW SPILLWAY
5 NOT TO SCALE
CONSTRUCTION ENTRANCE 1' MIN.INLET/OUTFALL PIPE
OUTFALL
P
I
P
E
SECTION VIEW
PLAN VIEW
EXISTING AND/OR
PROPOSED GROUND
12" MIN. DEPTH (12"Ø PIPE)
18" MIN. DEPTH (15"-18"Ø PIPE)
24" MIN. ( 24"-36"Ø PIPE)
4" MIN. FACE
QUARRY ROCK
DIA. +4"
6 NOT TO SCALE
ROCK OUTFALL
3
1 1
6' MIN.
2
0.5' SPILLWAY DEPTH
1' FREEBOARD
MIN. 2' SETTLING DEPTH
MAX. 4' SETTLING DEPTH
EMERGENCY
OVERFLOW
SPILLWAY CREST,
OUTLET BERM
FILTER FABRIC
FENCE
ENERGY DISSIPATING
ROCK
SEDIMENT STORAGE
1' DEPTH (3' MAX)
6'-0"
2
1
5/8" MINUS
WASHED
ROCK
6.5' SEPARATION FROM PERMANENT
INFILTRATION FACILITY SUBGRADE
ELEV: 326.53
ELEV: 333.00
ELEV: 336.00
ELEV: 337.00
ELEV: 337.50
OVERFLOW SPILLWAY
6' MINIMUM WIDTH
0.5' FREEBOARD
1' OF 3 4" -3" WASHED ROCK
1' OF QUARRY SPALLS
SPILLWAY ELEV
337.00 TOP OF BERM:
337.50
04/08/2022
1
2
3
4
TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
Know what's below.
before you dig.Call
R
27
STKTDSMTL
4/6/2022
PERMIT SET
2210633.10
P.O.BOX 73790
PUYALLUP, WA 98373-0790
EVAN MANN
COPPER RIDGE, LLC
CRYSTAL SPRINGS
A PORTION OF THE NE 1/4 OF THE NW 1/4 OF SEC. 19, TWN. 17 N., RGE. 02 E. W.M.
CITY OF YELM, THURSTON COUNTY, WASHINGTON.
CRYSTAL SPRINGS
APPLICATION #
CONSTRUCTION NOTES
5.
4.
3.
2.UTILITIES INSPECTOR PRIOR TO CONSTRUCTION.
SHALL SECURE THE NECESSARY PERMITS FROM THE YELM
CONSTRUCTED IN THE YELM RIGHT-OF-WAY, THE APPLICANT
IF WATER OR OTHER UTILITIES ARE REQUIRED TO BE
BE IN ATTENDANCE.
THE DEVELOPER AND HIS/HER CONTRACTOR(S) MUST
YELM'S DEVELOPMENT AND UTILITIES INSPECTOR.
PRECONSTRUCTION CONFERENCE SHALL BE SCHEDULED WITH
OR IMPROVEMENTS TO EXISTING ROADWAY FACILITIES, A
PRIOR TO ANY ON SITE IMPROVEMENTS, ROADWAY CONSTRUCTION,
CONSTRUCTED FACILITIES OR ADJACENT PROPERTIES.
UNDERTAKEN DURING CONSTRUCTION TO AVOID DAMAGE TO
TEMPORARY EROSION AND SEDIMENTATION CONTROL SHALL BE
IS RESPONSIBLE FOR SCHEDULING THIS WORK.
QUALIFIED LICENSED SURVEYOR. THE DEVELOPER OR CONTRACTOR
CONSTRUCTION STAKING SHALL BE BY THE DESIGN ENGINEER OR A
CONSTRUCTION USE BY THE ENGINEER.
RESPECTS, INCLUDING SAND EQUIVALENT, WILL BE APPROVED FOR
NATIVE MATERIALS MEETING THE SPECIFICATIONS IN ALL
ASSOCIATION, AND CITY OF YELM PUBLIC WORKS STANDARDS.
AND WASHINGTON STATE CHAPTER, AMERICAN PUBLIC WORKS
JOINTLY BY WASHINGTON STATE DEPARTMENT OF TRANSPORTATION
FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION, PUBLISHED
MOST CURRENT STANDARD SPECIFICATIONS FOR ROAD SPECIFICATIONS
WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH THE1.
A SILT SOCK SHALL BE INSTALLED AT EACH CATCH BASIN LOCATION.6.
SEDIMENTS OR BUILD A NEW FENCE PARALLEL TO THE OLD ONE.
WHEN SEDIMENT BUILDUP BECOMES EXCESSIVE, REMOVE THE
AND DAILY DURING PROLONGED RAIN AND REPAIR THEM AS NECESSARY.
POSSIBLE. INSPECT FILTER FABRIC FENCES AFTER EACH RUNOFF EVENT
STORM WATER DISCHARGED OFF SITE IS AS FREE OF SEDIMENT AS
9. FILTER FABRIC FENCES SHALL BE MAINTAINED IN ORDER THAT
DURING CONSTRUCTION AND SHALL WATER DOWN AREAS AS NECESSARY
7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DUST CONTROL ON SITE
AND IN CONFORMANCE WITH THE PERTINENT CITY OF YELM ORDINANCES.
STABILIZED BY SEEDING AND MULCHING.
UNWORKED REGULARLY OR FOR AN EXTENDED TIME SHALL BE
DISTURBED AREAS GREATER THAN 5,000 S.F. THAT ARE LEFT
5. DURING THE TIME PERIOD OF NOVEMBER 1 THROUGH APRIL 30, ALL
6. STOCKPILED DIRT MATERIAL SHALL BE COVERED.
BY THE CITY.
THROUGHOUT DURATION OF PROJECT CONSTRUCTION AS DIRECTED
4. CONTRACTOR SHALL MAINTAIN ALL EROSION CONTROL DEVICES
ROCK ACCESS DRIVEWAY SHALL BE IN PLACE, AS SHOWN ON PLAN.
3. PRIOR TO ANY OTHER WORK ON SITE, EROSION CONTROL FENCING AND
CITY OF YELM OR OTHER GOVERNING AUTHORITY OR AGENCY.
2. COMPLY WITH ALL OTHER PERMITS AND OTHER REQUIREMENTS BY
FOLLOWING COMPLETION OF CONSTRUCTION.
SHALL BE CLEANED OF ALL SILTS, SAND AND OTHER MATERIALS
WATER POLLUTION/FLOOD ACTIVITIES AND CONVEYANCE SYSTEMS
USED AS PART OF THE TEMPORARY EROSION CONTROL AND
B. ALL PERMANENT STORAGE AND DETENTION AREAS
MANUAL.
REQUIREMENTS OF TABLE 9.1 OF THE THURSTON REGION DRAINAGE
8. ALL DISTURBED AREAS SHALL BE SEEDED PER THE STABILIZATION
PRECLUDE ANY CONSTRUCTION ACTIVITY ON THE SITE.
SUBMITTAL AND APPROVAL OF THESE PLANS SHALL
SHALL BE SUBMITTED TO AND APPROVED BY THE COUNTY.
A. SOIL EROSION AND WATER POLLUTION/FLOOD CONTROL PLANS
SPECIFICATIONS AND AS FOLLOWS:
REQUIRED IN ACCORDANCE WITH SECTION 1-07.15 OF THE STANDARD
1. TEMPORARY EROSION/WATER POLLUTION MEASURES SHALL BE
DRAINAGE, GRADING AND
OTHER TREATMENT.
CONTRACTOR, BUT MUST BE AUGMENTED WITH MULCH, NETTING, OR
HOWEVER, WHENEVER IT IS IN THE INTEREST OF THE APPLICANT/
APRIL THROUGH SEPTEMBER, INCLUSIVE. SEEDING MAY PROCEED,
SEEDING ALONE WILL BE ACCEPTABLE ONLY DURING THE MONTHS OF
TREATMENT APPLICABLE TO THE TIME OF YEAR IN QUESTION. GRASS
MULCHING, GRASS PLANTING OR OTHER APPROVED EROSION CONTROL
MORE, ALL DISTURBED AREAS MUST BE IMMEDIATELY STABILIZED WITH
NO FURTHER WORK IS ANTICIPATED FOR A PERIOD OF 30 DAYS OR
16. IN ANY AREA WHICH HAS BEEN STRIPPED OF VEGETATION AND WHERE
AND/OR STORM DRAINAGE SYSTEMS.
ADJACENT PROPERTIES, SENSITIVE AREAS, NATURAL WATER COURSES
SHALL INSTALL ADDITIONAL FACILITIES AS NECESSARY TO PROTECT
CONTROL EROSION AND SEDIMENTATION, THE APPLICANT/CONTRACTOR
MEASURES AS SHOWN ON THIS DRAWING NOT PROVE ADEQUATE TO
15. SHOULD THE TEMPORARY EROSION AND SEDIMENTATION CONTROL
SATISFIED.
CONTINUE UNTIL SUCH TIME AS THE AFFECTED PROPERTY OWNER IS
COMMENCE RESTORATION METHODS. RESTORATION ACTIVITY WILL
MUST CEASE, AND THE OWNER/CONTRACTOR WILL IMMEDIATELY
DEVELOPMENT THAT WILL AGGRAVATE THE SITUATION IN THE FUTURE
PROPERTY OWNERS, ALL CONSTRUCTION WORK WITHIN THE
14. IN CASE EROSION OR SEDIMENTATION OCCURS TO ADJACENT
IN A FIELD BY A SOILS ENGINEER OR ENGINEERING GEOLOGIST.
NATIVE SOILS. HEIGHT AND WIDTH OF THE BENCH WILL BE DETERMINED
(HORIZONTAL TO VERTICAL) SHALL BE BENCHED AS DIRECTED INTO
13. PLACEMENT OF FILL SECTIONS ON SLOPES GREATER THAN 4:1
BACKFILL SHALL BE COMPACTED AS SPECIFIED ABOVE.
DENSITY BEFORE PLACING THE NEXT LIFT. ALL UTILITY TRENCH
MOISTURE CONTENT, AND COMPACTED TO THE SPECIFIED MINIMUM
EIGHT INCHES LOOSE THICKNESS, CONDITIONED TO THE OPTIMUM
12. ALL FILL SHALL BE PLACED IN UNIFORM HORIZONTAL LIFTS OF SIX TO
CONSULTANT FOR USE.
SUBSTITUTED WITH PRIOR APPROVAL BY A GEOTECHNICAL
ANSI/ASTM D-1140 TEST PROCEDURE. OTHER MATERIAL MAY BE
MORE THAN 7% BY WEIGHT SHALL PASS THE #200 SCREEN AS TESTED BY
DETERMINED BY ANSI/ASTM TEST METHOD D-2487) SHALL BE USED. NO
GRADED GRAVEL OR GRAVELY SAND (CLASSIFYING AS GW OR SW AS
11. FOR IMPORTED STRUCTURAL FILL A CLEAN, SIX-INCH MINUS, WELL
CONTROL FACILITIES ONLY WHEN THE ENTIRE SITE IS STABILIZED.
17. REMOVE ALL REMAINING TEMPORARY EROSION AND SEDIMENTATION
TEMPORARY EROSION CONTROL NOTES
IN AREAS UNDER STRUCTURES, PAVING SECTIONS, SIDEWALKS, AND OTHER
AREAS TO BE GRADED, STRIP ALL TOPSOIL AND ORGANIC MATERIAL.
STOCKPILE AND COVER WITH PLASTIC ALL STOCKPILED TOPSOIL. ALL TOPSOIL
AND SOD NOT TO BE REUSED SHALL BE REMOVED FROM SITE AND DISPOSED
OF PROPERLY AT THE CONTRACTORS EXPENSE. FOR STRUCTURAL FILL IN
AREAS UNDER FOOTINGS AND SLABS ON GRADE, ALL SOILS SHALL BE
COMPACTED TO A MINIMUM DENSITY OF 90% OF ASTM D-1557 OR 95% OF
UBC 70-1. THIS INCLUDES PROOF-ROLLING NATIVE SOILS EXPOSED IN THE
BOTTOM OF THE EXCAVATION PRIOR TO PLACEMENT OF FILL. MATERIALS
UNDER THE PAVING SECTION SHALL ALSO BE COMPACTED TO THE MINIMUM
DENSITY BY PROOF-ROLLING PRIOR TO PLACEMENT OF THE PAVING SECTION;
THIS INCLUDES PROOF-ROLLING IN-PLACE SOILS, SOILS THAT HAVE BEEN
DISTURBED DURING CONSTRUCTION AND ALL STRUCTURAL FILL MATERIALS.
1.STOCKPILES SHALL BE STABILIZED (WITH PLASTIC COVERING OR OTHER
APPROVED DEVICE) DAILY BETWEEN NOVEMBER 1 AND MARCH 31.
2.IN ANY SEASON, SEDIMENT LEACHING FROM STOCK PILES MUST BE PREVENTED.
3.TOPSOIL SHALL NOT BE PLACED WHILE IN A FROZEN OR MUDDY CONDITION, WHEN
THE SUBGRADE IS EXCESSIVELY WET, OR WHEN CONDITIONS EXIST THAT MAY
OTHERWISE BE DETRIMENTAL TO PROPER GRADING OR PROPOSED SODDING OR
SEEDING.
4.PREVIOUSLY ESTABLISHED GRADES ON THE AREAS TO BE TOPSOILED SHALL BE
MAINTAINED ACCORDING TO THE APPROVED PLAN.
1.MULCH MATERIALS USED SHALL BE HAY OR STRAW, AND SHALL BE APPLIED
AT THE RATE OF 2 TONS/ACRE. (MIN. 2" THICK)
2.MULCHES SHALL BE APPLIED IN ALL AREAS WITH EXPOSED SLOPES
GREATER THAN 2:1.
3.MULCHING SHALL BE USED IMMEDIATELY AFTER SEEDING OR IN AREAS
WHICH CANNOT BE SEEDED BECAUSE OF THE SEASON.
4.ALL AREAS NEEDING MULCH SHALL BE COVERED BY NOVEMBER 1.
1.CONTRACTOR SHALL DESIGNATE A WASHINGTON STATE CERTIFIED EROSION
AND SEDIMENT CONTROL LEAD WHO SHALL HAVE THE RESPONSIBILITY TO
MONITOR AND IMPLEMENT EROSION CONTROL MEASURES.
2.CONTRACTOR SHALL PROVIDE AN EROSION AND SEDIMENT CONTROL LEAD
(ESCL) WHO WILL BE ON-SITE OR ON CALL AT ALL TIMES. THE EROSION
CONTROL LEAD SHALL HAVE THE AUTHORITY TO IMPLEMENT THE
STORMWATER POLLUTION PREVENTION PLAN BASED ON SITE CONDITIONS
WITHIN THEIR SCOPE. IF THE METHODS INDICATED FOR EROSION AND
SEDIMENT CONTROL ARE NOT ADEQUATE, THE ESCL SHALL IMPLEMENT
ADDITIONAL METHODS AS REQUIRED.
3.CONTRACTOR SHALL PREPARE A CONSTRUCTION SWPPP FOR THIS PROJECT.
REFER TO THE PROJECT MANUAL FOR A SAMPLE SWPPP FOR THIS PROJECT.
RETAIN A COPY OF THE SWPPP ON-SITE AT ALL TIMES AND AVAILABLE TO THE
JURISDICTIONS HAVING AUTHORITY.
4.CONTRACTOR TO COORDINATE AREAS FOR LAY DOWN, STOCK PILE, TRAILERS
& PARKING WITH WMD CONSTRUCTION PROJECT MANAGER BRAD OLSON.
5.CONTRACTOR TO REMOVE CONSTRUCTION DEBRIS, MUD, ROCKS, DIRT, ETC
FROM EXISTING ROAD AND PARKING LOT DAILY.
MULCHING NOTES
TESC/SWPPP NOTES
SOIL STOCKPILE NOTES
1.THE FILTER FABRIC SHALL BE PURCHASED IN A CONTINUOUS ROLL CUT TO THE LENGTH OF THE
BARRIER TO AVOID USE OF JOINTS. WHEN JOINTS ARE NECESSARY, FILTER CLOTH SHALL BE SPLICED
TOGETHER ONLY AT A SUPPORT POST WITH A MINIMUM SIX-INCH OVERLAP, AND BOTH ENDS
SECURELY FASTENED TO THE POST.
2.THE FILTER FABRIC FENCE SHALL BE INSTALLED TO FOLLOW THE CONTOURS (WHERE FEASIBLE). THE
FENCE POSTS SHALL BE SPACED A MAXIMUM OF SIX FEET APART AND DRIVEN SECURELY INTO THE
GROUND (MINIMUM OF 30")
3.A TRENCH SHALL BE EXCAVATED, ROUGHLY EIGHT INCHES WIDE AND TWELVE INCHES DEEP, UPSLOPE
AND ADJACENT TO THE WOOD POST TO ALLOW THE FILTER FABRIC TO BE BURIED.
4.WHEN STANDARD STRENGTH FILTER FABRIC IS USED, A WIRE MESH SUPPORT FENCE SHALL BE
FASTENED SECURELY TO THE UPSLOPE SIDE OF THE POSTS USING HEAVY-DUTY WIRE STAPLES AT
LEAST ONE INCH LONG, TIE WIRES, OR HOG RINGS. THE WIRE SHALL EXTEND INTO THE TRENCH A
MINIMUM OF FOUR INCHES AND SHALL NOT EXTEND MORE THAN THIRTY SIX INCHES ABOVE THE
ORIGINAL GROUND SURFACE.
5.THE STANDARD STRENGTH FILTER FABRIC SHALL BE STAPLED OR WIRED TO THE FENCE, AND TWENTY
INCHES OF THE FABRIC SHALL BE EXTENDED INTO THE TRENCH. THE FABRIC SHALL NOT EXTEND
MORE THAN THIRTY SIX INCHES ABOVE THE ORIGINAL GROUND SURFACE. FILTER FABRIC SHALL NOT
BE STAPLED TO EXISTING TREES.
6.WHEN EXTRA-STRENGTH FILTER FABRIC AND CLOSER POST SPACING ARE USED, THE WIRE MESH
SUPPORT FENCE MAY BE ELIMINATED. IN SUCH A CASE, THE FILTER FABRIC IS STAPLED OR WIRED
DIRECTLY TO THE POSTS WITH ALL OTHER PROVISIONS OF STANDARD NOTE (S) APPLYING.
7.THE TRENCH SHALL BE BACKFILL WITH 3/4 INCH MINIMUM DIAMETER WASHED GRAVEL.
8.FILTER FABRIC FENCES SHALL BE REMOVED WHEN THEY HAVE SERVED THEIR USEFUL PURPOSE, BUT
NOT BEFORE THE UPSLOPE AREA HAS BEEN PERMANENTLY STABILIZED.
9.FILTER FABRIC FENCES SHALL BE INSPECTED IMMEDIATELY AFTER EACH RAINFALL AND AT LEAST
DAILY DURING PROLONGED RAINFALL. ANY REQUIRED REPAIRS SHALL BE MADE IMMEDIATELY.
10.CONTRIBUTING LENGTH TO FENCE SHALL NOT BE MORE THAN 100 FEET.
11.DO NOT INSTALL BELOW AN OUTLET PIPE OR WEIR.
12.DO NOT DRIVE OVER OR FILL OVER FILTER FABRIC FENCE.
SIDE VIEW
NOTES:
FRONT VIEW
CHAINLINK FENCE
8"
2.0' MIN.5.0'1.0'2.0'0.5'6' MAX.
5.0'
2.0'
2.5'
2" X 4" WOOD POSTS,
STANDARD OR BETTER,
OR STEEL FENCE POST
BURY BOTTOM OF
FILTER MATERIAL
IN 8"X12" TRENCH
2" X 4" BY 14 GA.
WIRE FABRIC OR
EQUIVALENT
EXISTING
GRADE
ORANGE FILTER FABRIC
MATERIAL 60" WIDE ROLLS -
USE RINGS TO ATTACH
ATTACH TO WIRE FABRIC
2" X 4" WOOD POST
OR STEEL FENCE POST
PROVIDE 3/4" - 1 1/2" WASHED
GRAVEL BACKFILL IN TRENCH AND
ON BOTH SIDES OF FILTER FENCE
FABRIC ON THE SURFACE
2" X 2" BY 14 GA. WIRE
FABRIC OR EQUIVALENT,
AFFIX TO POST
FILTER FABRIC MATERIAL
MIRAFI 100 NS OR EQUIVALENT
DATE: April 6, 2022 FILENAME: Q:\2021\2210633\10_CIV\CAD\_FINAL DESIGN\_2210633-SH-TESC.dwg
C2.3
6
TESC NOTES AND
DETAILS
1 NOT TO SCALE
FILTER FABRIC FENCE
2' MIN
1' MIN.
2
1
SPACING (FEET)
2
1
1' MIN
SLOPE
1.SEED AND MULCH SHALL BE APPLIED WITHIN 5 DAYS OF DIKE
CONSTRUCTION. (SEE HYDROSEEDING NOTES)
2.THE UPSLOPE SIDE OF THE DIKE SHALL PROVIDE POSITIVE DRAINAGE
TO THE DIKE OUTLET.
3.NO EROSION SHALL OCCUR AT THE DIKE OUTLET. PROVIDE ENERGY
DISSIPATION MEASURES AS NECESSARY.
4.SEDIMENT LADEN RUNOFF MUST BE RELEASED THROUGH A SEDIMENT
TRAPPING FACILITY SUCH AS A POND, TRAP, OR SILT FENCE AS
APPROPRIATE TO DRAINAGE AREA SIZE.
TEMPORARY DIKE AND SWALE NOTES
GRASS OR ROCK
LEVEL BOTTOM
SPACING=100', 200' OR 300'
DEPENDING ON SLOPE
(SEE TABLE)
2 NOT TO SCALE
INTERCEPTOR SWALE
04/08/2022
31.50'
26.50'
R50.00'
ss
s ssssssss
INFLECTION POINT
STA:0+55.33 337336 ROAD A
1817121614111315
10
21
CB #3
CB #5
CB #4
CB #1
CB #2
51 LF 12" CPEP @ 0.50%37 LF 12" CPEP
@ 0.50%
142 LF 12" CPEP
@ 0.50%
38 LF 12" CPEP
@ 0.50%186 LF 12" CPEP
@ 0.98%
CENTER OF EXISTING
CUL-DE-SAC
STA:0+00.00, 0.00'
BEGIN ROAD A IMPROVEMENTS
NEAT SAWCUT AND HOT TAR SEAL
STA:0+35.11
END ROAD A IMPROVEMENTS
INSTALL PERMANENT BARRICADE
STA:3+77.24
ROAD A STA: 1+71.87 =
ROAD B STA: 14+89.10
CENTER OF CUL-DE-SAC
STA:3+31.08, 18.50' RT
R37.00'
PROVIDE MONUMENT
STA:0+55.33, 2.50' LT
PROVIDE MONUMENT
STA:1+74.30, 2.50' LT
CONSTRUCTION
CENTERLINE (TYP)
SEE SHEET C3.6 FOR
CUL-DE-SAC ENLARGMENT
N88° 53' 46"E
55.33'
S89° 36' 30"E
116.54'
S89° 36' 30"E
209.37'S1° 06' 14"E489.10'3393383373
39
338337
33
8
339339338336
338338339
338337
BEGIN SIDEWALK
STA:0+59.12, 25.50' LT
10.00' UTILITY
EASEMENT
(TYP)
1+00 2+00 3+00
320
325
330
335
340
345
350
320
325
330
335
340
345
350
0+00 0+50FG 335.98FG 336.261+00FG 336.93FG 337.681+50FG 338.43FG 339.162+00FG 339.68FG 339.942+50FG 339.96FG 339.733+00FG 339.25FG 338.543+50FG 337.79FG 337.040.50%
3.00
%
3.00%
BEGIN ROAD A
STA: 0+35.09
ELEV: 336.018
PVI: 335.87
PVI STA: 0+64.54
K: 14.29
50' VC
BVCS: 0+39.54BVCE: 336.00EVCS: 0+89.54EVCE: 336.62LOW PT: 0+46.69ELEV: 335.98PVI: 341.11
PVI STA: 2+39.26
K: 25.00
150' VC
BVCS: 1+64.26BVCE: 338.86EVCS: 3+14.26EVCE: 338.86HI PT: 2+39.23ELEV: 339.98EXISTING ELEVATION AT
CONSTRUCTION CENTERLINE
PROPOSED ELEVATION AT
CONSTRUCTION CENTERLINE
PROPOSED GRADE AT
CONSTRUCTION CENTERLINE
EXISTING GRADE AT
CONSTRUCTION CENTERLINE
END ROAD A
STA: 3+76.24
ELEV: 337.00
STA: 0+46.69, 18.72' LT
IE: 332.60 12" (S)
RIM: 335.50
CB #1, TYPE 1
37 LF 12" CPEP @ 0.50%
STA: 0+46.69, 18.72' RT
IE: 332.41 12" (N)
IE: 332.41 12" (E)
RIM: 335.50
CB #2, TYPE 1
142 LF 12" CPEP @ 0.50%
186 LF 12" CPEP
@
0
.
9
8
%
STA: 1+89.66, 18.34' RT
IE: 331.70 12" (W)
IE: 331.70 12" (S)
IE: 331.70 12" (E)
RIM: 338.89
CB #3, 48" TYPE 2
STA: 3+75.26, 19.12' RT
IE: 333.51 12" (N)
IE: 333.51 12" (W)
RIM: 336.48
CB #4, TYPE 1
STA: 3+75.16, 18.72' LT
IE: 333.70 12" (S)
RIM: 336.55
CB #5, TYPE 1
38 LF 12" CPEP @ 0.50%
PROPOSED 2" SDR 21 PVC
FORCE MAIN. SEE SHEET C6.1
ROAD B INTERSECTION
STA: 1+71.87
ELEV: 339.08
DRIVEWAY TABLE
LOT #
11
12
13
14
15
16
17
18
STATION
0+80.13, 19.49' LT
1+12.91, 19.49' LT
1+60.13, 19.50' LT
1+92.91, 19.49' LT
2+40.13, 19.50' LT
2+72.91, 19.50' LT
3+20.13, 19.50' LT
3+52.91, 19.50' LT
WIDTH
20'
20'
20'
20'
20'
20'
20'
20'
1
2
3
4
TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
Know what's below.
before you dig.Call
R
27
STKTDSMTL
4/6/2022
PERMIT SET
2210633.10
P.O.BOX 73790
PUYALLUP, WA 98373-0790
EVAN MANN
COPPER RIDGE, LLC
CRYSTAL SPRINGS
A PORTION OF THE NE 1/4 OF THE NW 1/4 OF SEC. 19, TWN. 17 N., RGE. 02 E. W.M.
CITY OF YELM, THURSTON COUNTY, WASHINGTON.
CRYSTAL SPRINGS
APPLICATION #
DATE: April 5, 2022 FILENAME: Q:\2021\2210633\10_CIV\CAD\_FINAL DESIGN\_2210633-SH-ROAD.dwg
C3.1
7
ROAD A PLAN &
PROFILE
N
GRAPHIC SCALE
0 30 60
1" = 30 FEET
15
ROAD A
SCALE: H:1"=30', V:1"=3'ROAD B2H:1V DAYLIGHT
SLOPEPROPOSED 8" C900 WATER MAIN
SEE SHEET C5.1
SEE SHEET C3.5 FOR
INTERSECTION DESIGN
1
C3.6
ASPHALT WEDGE CURB 1
C3.7
1
C3.5
1
C3.9
04/08/2022
24+0025+00ROAD AROAD Css
sssss ss ss
ssss
ssssss339
ROAD B 1+002+0011+00 12+00 13+00 14+00
CB #3
CB #11 CB #10
CO #1
CO #2
CB #21
CB #20
CO #3
CB #19
CB #9
CB #8
CB #7
CB #6
66 LF 12" CPEP @ 0.50%
8 LF 12" CPEP
@ 0.50%
10 LF 12" CPEP
@ 0.00%
51 LF 12" CPEP
@ 0.50%
162 LF 12" CPEP
@ 0.50%
109 LF 12"
C
P
E
P
@
3
.
1
4
%
37 LF 12" CPEP @ 4.48%
142 LF 12" CPEP
@ 0.50%
27 LF 12" CPEP @ 16.49%
21 LF 12" CPEP
@ 0.53%
303 LF 12" CPEP @ 0.41%
30 LF 12" CPEP @ 4.09%
TRACT A
12
14
13
9
15
23
61234
1078
25 2124
5
22
338
338
33
8
33933
8
33
7337
337
337
337
3
3
8338
339339ROAD B STA: 10+00 =
ROAD C STA: 24+91.00
ROAD B STA: 14+89.10 =
ROAD A STA: 1+71.87
STA:10+02.90, 2.50' RT STA:14+91.54, 2.50' RT
S89° 36' 30"E209.37'S89° 36' 30"E116.54'S88° 44' 20"E73.98'N88° 44' 20"W521.01'S1° 06' 14"E
489.10'
320
325
330
335
340
345
350
320
325
330
335
340
345
350
10+00FG 339.04FG 338.5410+50FG 338.04FG 337.5611+00FG 337.28FG 337.2311+50FG 337.39FG 337.5712+00FG 337.74FG 337.9212+50FG 338.09FG 338.2713+00FG 338.44FG 338.6213+50FG 338.66FG 338.4614+00FG 338.13FG 338.0114+50FG 338.30FG 338.8015+00FG0.70%
1.32%
2.00%2.00%
ROAD C INTERSECTION
STA: 10+00.00
ELEV: 339.04
ROAD A INTERSECTION
STA: 14+89.10
ELEV: 339.08
PVI: 337.04
PVI STA: 11+00.00
K: 26.00
70' VC
BVCS: 10+64.90BVCE: 337.74EVCS: 11+35.10EVCE: 337.29LOW PT: 11+16.90ELEV: 337.22PVI: 337.80
PVI STA: 14+25.16
K: 15.08
50' VC
BVCS: 14+00.16BVCE: 338.13EVCS: 14+50.16EVCE: 338.30LOW PT: 14+20.00ELEV: 338.00PVI: 338.79
PVI STA: 13+50.01
K: 24.80
50' VC
BVCS: 13+25.01BVCE: 338.62EVCS: 13+75.01EVCE: 338.46HI PT: 13+42.37ELEV: 338.68EXISTING ELEVATION AT
CONSTRUCTION CENTERLINE
PROPOSED ELEVATION AT
CONSTRUCTION CENTERLINE
PROPOSED GRADE AT
CONSTRUCTION CENTERLINE
EXISTING GRADE AT
CONSTRUCTION CENTERLINE
PROPOSED 8" C900 PVC WATER MAIN
SEE SHEET C5.2
PROPOSED 2" SDR 21 PVC FORCE MAIN
SEE SHEET C6.2
21 LF 12" CPEP @ 0.53%
STA: 25+24.58, 10.39' RT
IE: 333.75 12" (W)
IE: 333.75 12" (N)
RIM: 339.01
CB #11, 48" TYPE 2
STA: 25+24.59, 10.14' LT
IE: 333.64 12" (N)
IE: 333.64 12" (S)
RIM: 339.03
CB #10, 48" TYPE 2
109
L
F
1
2
"
C
P
E
P
@
3
.
1
4
%
37 LF 12" CPEP @ 4.48%
STA: 11+16.95, 18.72' LT
IE: 331.84 12" (E)
RIM: 336.74
CB #9, TYPE 1
51 LF 12" CPEP
@ 0.50%
STA: 1+89.66, 18.34' RT
IE: 331.70 12" (W)
IE: 331.70 12" (S)
IE: 331.70 12" (E)
RIM: 338.89
CB #3, 48" TYPE 2
STA: 11+16.95, 17.89' RT
IE: 330.20 12" (N)
IE: 330.20 12" (N)
IE: 330.20 12" (S)
IE: 330.20 12" (W)
RIM: 336.74
CB #8, 48" TYPE 2
STA: 14+19.82, 14.48' RT
IE: 331.45 12" (N)
IE: 331.45 12" (S)
IE: 331.45 12" (W)
RIM: 337.58
CB #6, 48" TYPE 2
30 LF 12" CPEP @ 4.09%
STA: 14+20.06, 15.83' LT
IE: 332.69 12" (E)
RIM: 337.59
CB #7, TYPE 1
303 LF 12" CPEP @ 0.41%
DRIVEWAY TABLE
LOT #
1
2
3
4
5
6
7
8
9
10
21
22
23
24
25
STATION
10+66.83, 15.25' LT
10+98.83, 19.50' LT
11+46.83, 19.50' LT
11+78.83, 19.50' LT
12+26.83, 19.50' LT
12+58.83, 19.50' LT
13+06.83, 19.50' LT
13+38.83, 19.50' LT
13+86.83, 19.50' LT
14+18.91, 16.99' LT
14+14.68, 17.72' RT
13+74.50, 19.50' RT
13+42.50, 19.50' RT
12+94.50, 19.50' RT
12+62.50, 19.50' RT
WIDTH
20'
20'
20'
20'
20'
20'
20'
20'
20'
20'
20'
20'
20'
20'
20'
1
2
3
4
TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
Know what's below.
before you dig.Call
R
27
STKTDSMTL
4/6/2022
PERMIT SET
2210633.10
P.O.BOX 73790
PUYALLUP, WA 98373-0790
EVAN MANN
COPPER RIDGE, LLC
CRYSTAL SPRINGS
A PORTION OF THE NE 1/4 OF THE NW 1/4 OF SEC. 19, TWN. 17 N., RGE. 02 E. W.M.
CITY OF YELM, THURSTON COUNTY, WASHINGTON.
CRYSTAL SPRINGS
APPLICATION #
DATE: April 5, 2022 FILENAME: Q:\2021\2210633\10_CIV\CAD\_FINAL DESIGN\_2210633-SH-ROAD 2.dwg
C3.2
8
ROAD B PLAN &
PROFILENGRAPHIC SCALE
0 30 60
1" = 30 FEET
15
ROAD B
SCALE: H:1"=30', V:1"=3'
INFILTRATION FACILITY
SEE SHEET C4.2
1
C4.2
PROVIDE PERMANENT
BARRICADE
1
C3.9
04/08/2022
20+00 21+00 22+00 23+00 24+00 25+00
17.00'
23.00'CRYSTAL SPRINGS ST NWROAD C
TRACT A
1
SHALLOW GRASS LINED SWALE
CB #11
CB #10
CB #12
CB #13
CB #18
CB #17
CB #16
CB #15
CB #14
22 LF 12"
CPEP @ 0.50%
159 LF 12" CPEP @ 0.50%105 LF 12" CPEP @ 3.14%5 LF 12" CPEP @ 0.44%
16 LF 12" CPEP @ 0.91%
34 LF 12" PERF. CPEP @ 0.00%
21 LF 12"
CPEP @ 0.53%96+00ROAD C STA: 19+70.01 =
CRYSTAL SPRINGS ST NW STA: 96+27.76
ROAD C STA: 24+91 =
STA: 10+00.00
SEE SHEET C3.5 FOR INTERSECTION DETAIL
PROVIDE MONUMENT
STA:24+93.38, 3.00' LT
S88° 44' 20"E
521.01'
S88° 44' 20"E
73.98'
150 SF X 4' INFILTRATION GALLERY
5.00'
END ROAD C IMPROVEMENTS
PROIVDE PERMANENT BARRICADE
STA:25+60.01
315
320
325
330
335
340
345
350
315
320
325
330
335
340
345
350
19+50FG FG20+00FG 332.49FG 332.6520+50FG 333.57FG 334.5221+00FG 335.23FG 335.7221+50FG 336.00FG 336.2222+00FG 336.45FG 336.6722+50FG 336.89FG 337.1223+00FG 337.34FG 337.5623+50FG 337.78FG 338.0124+00FG 338.23FG 338.4524+50FG 338.68FG 338.9025+00FG 339.12FG 339.3425+50FG 339.572.00%
0.89%
BEGIN ROAD C: 19+88.71
ELEV: 332.680
END ROAD C
STA: 25+60.01
ELEV:339.66
PVI: 332.11
PVI STA: 20+17.23
K: 7.69
50' VC
BVCS: 19+92.23BVCE: 332.61EVCS: 20+42.23EVCE: 333.23LOW PT: 20+07.61ELEV: 332.46PVI: 335.49
PVI STA: 20+92.25
K: 27.71
100' VC
BVCS: 20+42.25BVCE: 333.24EVCS: 21+42.25EVCE: 335.93EXISTING ELEVATION AT
CONSTRUCTION CENTERLINE
PROPOSED ELEVATION AT
CONSTRUCTION CENTERLINE
PROPOSED GRADE AT
CONSTRUCTION CENTERLINE
EXISTING GRADE AT
CONSTRUCTION CENTERLINE
PROPOSED GRADE
AT BACK OF SIDEWALK
TOP ELEV: 328.46
BOT ELEV: 324.46
SCARIFY INFILTRATION SUBGRADE
PRIOR TO BACKFILL
2H:1V MAX
DAYLIGHT SLOPE
30.00'
4.00'
WRAP TOP AND SIDES OF
TRENCH WITH GEOTEXTILE
FABRIC MIRAFI 140N
OR EQUIVALENT
WASHED DRAIN ROCK
PER WSDOT STD 9-03.12(5)
GRAVEL BACKFILL FOR
DRY WELLS
STA: 25+24.59, 10.14' LT
IE: 333.64 12" (N)
IE: 333.64 12" (S)
RIM: 339.03
CB #10, 48" TYPE 2
21 LF 12" CPEP @ 0.53%
STA: 25+24.58, 10.39' RT
IE: 333.75 12" (W)
IE: 333.75 12" (N)
RIM: 339.01
CB #11, 48" TYPE 2
162 LF 12" CPEP @ 0.50%
STA: 23+63.01, 11.22' RT
IE: 334.56 12" (N)
IE: 334.56 12" (E)
RIM: 337.57
CB #12, TYPE 1
22 LF 12" CPEP @ 0.50%
STA: 23+63, 11.22' LT
IE: 334.67 12" (S)
RIM: 337.57
CB #13, TYPE 1
STA: 21+50.09, 14.48' LT
RIM: 333.80
CB #18, 48" TYPE 2
DRYWELL
STA: 20+45.97, 6.09' RT
IE: 325.46 12" (W)
RIM: 333.28
CB #17, 48" TYPE 2
STA: 20+05.56, 11.22' RT
IE: 327.80 12" (NE)
RIM: 332.13
CB #14, TYPE 1
8 LF 12" CPEP @ 0.44%
STA: 20+12.13, 6.17' RT
IE: 327.76 12" (SW)
IE: 327.76 12" (N)
IE: 325.46 12" (E)
RIM: 332.35
CB #16, 48" STORMFILTER
19 LF 12" CPEP @ 0.91%STA: 20+05.56, 11.22' LT
IE: 327.93 12" (S)
RIM: 332.13
CB #15, TYPE 1
34 LF 12" PERF.
CPEP @ 0.00%
330
335
340
330
335
340
0+00 FG 335.680+50FG 335.480+66.12
40' ROW
CONSTRUCTION
CENTERLINE
ROW
BOUNDARYROW
BOUNDARY
EX. GRADE ELEV.
@
CONSTRUCTION
CL
FINISHED GRADE
ELEV. @
CONSTRUCTION CL
EX. GRADE
FINISHED
GRADE
333
335
340
333
335
340
0+00 FG 335.620+50FG 335.160+68.50
40' ROW
17'23'
EX. GRADE ELEV.
@
CONSTRUCTION
CL
FINISHED GRADE
ELEV. @
CONSTRUCTION CL
CONSTRUCTION
CENTERLINE
ROW
BOUNDARY
ROW
BOUNDARY
EX. GRADE
FINISHED
GRADE
333
335
340
333
335
340
0+00FG 336.57FG 336.660+50FG 337.12FG0+76.62FG40' ROW
PROP. LINE
FINISHED
GRADE
EX. GRADE
EX. GRADE ELEV.
@
CONSTRUCTION
CL
FINISHED GRADE
ELEV. @
CONSTRUCTION CL
ROW
BOUNDARY
17'23'
CONSTRUCTION
CENTERLINE
SIDEWALK
1
2
3
4
TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
Know what's below.
before you dig.Call
R
27
STKTDSMTL
4/6/2022
PERMIT SET
2210633.10
P.O.BOX 73790
PUYALLUP, WA 98373-0790
EVAN MANN
COPPER RIDGE, LLC
CRYSTAL SPRINGS
A PORTION OF THE NE 1/4 OF THE NW 1/4 OF SEC. 19, TWN. 17 N., RGE. 02 E. W.M.
CITY OF YELM, THURSTON COUNTY, WASHINGTON.
CRYSTAL SPRINGS
APPLICATION #
DATE: April 6, 2022 FILENAME: Q:\2021\2210633\10_CIV\CAD\_FINAL DESIGN\_2210633-SH-ROAD 3.dwg
C3.3
9
ROAD C PLAN
AND PROFILE
N
GRAPHIC SCALE
0 30 60
1" = 30 FEET
15
ROAD C
SCALE: H:1"=30', V:1"=3'ROAD B1 SCALE: 1"=30'H 1"=3'V
STA 21+63
2 SCALE: 1"=30'H 1"=3'V
STA 22+88
3 SCALE: 1"=30'H 1"=3'V
STA 24+35
1
C3.3 2
C3.3
3
C3.3
SWALE
SIDEWALK 17'
23'
SWALE
SIDEWALK
1
C3.9
04/08/2022
328
330
335
340
345
328
330
335
340
345
50+00FG 337.7450+50FG 337.6851+00FG 337.8851+50FG 338.4552+00FG 339.0152+26.10FGFG 337.75FG 337.60FG 338.16FG 338.73FG2.0%
1.1%
ROAD B CONSTUCTION
CENTERLINE
ROW BOUNDARY
31.50'
END SHARED ACCESS
STA: 52+21.10
ELEV: 339.25
BEGIN SHARED ACCESS
STA: 50+57.83
ELEV: 337.76
FINISHED GRADE ELEVATION AT
CONSTRUCTION CENTERLINE
EXISTING GRADE ELEVATION AT
CONSTRUCTION CENTERLINE
CB #19, TYPE 1
STA 12+05.89, 43.50' RT
RIM: 337.44
IE: 334.37 12" (S)
FINISHED GRADE AT
CONSTRUCTION CENTERLINE
EXISTING GRADE AT
CONSTRUCTION CENTERLINE
s
s
ss
ssss
s
TRACT B
(SHARED ACCESS)
CB #20
CB #21
CO #1
CB #19
338
12+00END SHARED ACCESS
STA:52+21.10
BEGIN SHARED ACCESS
STA:50+58.00
SHARED ACCESS STA: 50+26.50 =
ROAD B STA: 12+05.89
4
25
51+00 52+00 52+26
5
16.00'
27 LF 12" CPEP @ 16.49%
20.00'
29
2726
30 28
DRIVEWAY TABLE
LOT #
26
27
28
29
30
STATION
12+24.91, 144.23' RT
12+24.91, 176.25' RT
11+90.91, 175.07' RT
11+90.91, 143.05' RT
11+90.87, 95.02' RT
WIDTH
20'
20'
20'
20'
20'
1
2
3
4
TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
Know what's below.
before you dig.Call
R
27
STKTDSMTL
4/6/2022
PERMIT SET
2210633.10
P.O.BOX 73790
PUYALLUP, WA 98373-0790
EVAN MANN
COPPER RIDGE, LLC
CRYSTAL SPRINGS
A PORTION OF THE NE 1/4 OF THE NW 1/4 OF SEC. 19, TWN. 17 N., RGE. 02 E. W.M.
CITY OF YELM, THURSTON COUNTY, WASHINGTON.
CRYSTAL SPRINGS
APPLICATION #
DATE: April 6, 2022 FILENAME: Q:\2021\2210633\10_CIV\CAD\_FINAL DESIGN\_2210633-SH-ROAD-DETL.dwg
C3.4
10
TRACT B PLAN
AND PROFILE
CL PROFILE GRADE
2" HMA CI. 1/2" PG 64-22
2" CSTC
8" GRAVEL BASE
COMPACTED SUBGRADE
2%
2%2%2%
2%
40' RIGHT OF WAY
CL OF ROWCONSTRUCTION CLCEMENT CONCRETE
SIDEWALK PER YELM
DETAIL 2-11 SHEET C3.7
CEMENT CONCRETE ROLLED CURB
AND GUTTER PER YELM DETAIL 2-13
SHEET C3.7ROW ROW20' RIGHT OF WAY20' RIGHT OF WAY
3.0'
11.0'FLOW LINE1'BACK OF CURB5'
LANDSCAPE
11.0'FLOW LINE1'BACK OF CURB5'
LANDSCAPE
5'
SIDEWALK
1'
CL PROFILE GRADE
2" HMA CI. 1/2" PG 64-22
2" CSTC
8" GRAVEL BASE
COMPACTED SUBGRADE
2%
2%2%2%
2%
58' RIGHT OF WAY
CL OF ROWCONSTRUCTION CLCEMENT CONCRETE
SIDEWALK PER YELM
DETAIL 2-11 SHEET C3.7
CEMENT CONCRETE ROLLED CURB
AND GUTTER PER YELM DETAIL 2-13
SHEET C3.7ROW ROW29' RIGHT OF WAY29' RIGHT OF WAY
2.5'
18.5'FLOW LINE1'BACK OF CURB6'
LANDSCAPE
5'
SIDEWALK
1'18.5'FLOW LINE1'BACK OF CURB6'
LANDSCAPE
1'
1 NOT TO SCALE
LOCAL ACCESS RESIDENTIAL - ROAD A & B
2 NOT TO SCALE
LOCAL ACCESS RESIDENTIAL- ROAD C
3 NOT TO SCALE
SHARED ACCESS
TRACT B (SHARED ACCESS)
SCALE: 1"=30'H 1"=3'V
PROPOSED 2" SDR 21 PVC
FORCE MAIN. SEE SHEET
C6.1
PROPOSED 8" C900 PVC
WATER MAIN. SEE
SHEET C5.1
PROPERTY
LINE
30'
36' PRIVATE SHARED ACCESS
AND UTILITY TRACT
PROPERTY
LINE
4'
6" CONC. SIDEWALK
2%2%
1'1'
2" HMA CI. 1/2" PG 64-22
2" CSTC
8" GRAVEL BASE
COMPACTED SUBGRADE
N
GRAPHIC SCALE
0 30 60
1" = 30 FEET
15
04/08/2022
ss
2+00
ROAD A STA: 1+71.87 =
ROAD B STA: 14+89.10
PROVIDE MONUMENT
ROAD A STA:1+74.30, 2.50' LT
ECR
STA: 2+07.79, 11.00' RT
ELEV: 339.50
BCR
STA: 14+53.18, 11.00' RT
ELEV: 338.08
ECR
STA: 14+55.01, 11.00' LT
ELEV: 338.12
BCR
STA: 1+37.77, 11.00' RT
ELEV: 337.78
1/2Δ
FL: 339.01
3.46%2.75%FL: 339.18 FL: 339.27
FG: 339.66FG: 339.62
FG: 339.26
FG: 339.13
1/2Δ
FL: 338.06
ROAD A
ROAD BS89° 36' 30"E
116.54'
S89° 36' 30"E
209.37'S1° 06' 14"E489.10'CB #3
RIM: 338.89
FL: 339.47
FL: 339.32
338
339
33
9 33933833833925+00
ECR
STA: 24+54.53, 11.00' LT
ELEV: 338.43
BCR
STA: 10+36.48, 11.00' LT
ELEV: 338.03
BCR
STA: 25+24.59, 11.00' LT
ELEV: 339.06
ECR
STA: 10+33.58, 11.00' RT
ELEV: 338.13
CB #11
RIM: 339.01
CB #10
RIM: 339.03
S88° 44' 20"E
521.01'S88° 44' 20"E
73.98'S1° 06' 14"E489.10'ROAD BROAD C ROAD C STA: 24+91 =
ROAD B STA: 10+00.00
PROVIDE MONUMENT
ROAD C STA:24+93.38, 3.00' LT
1/2Δ
FL: 338.61
1/2Δ
FL: 338.83
FL: 338.63
FL: 338.56
FL: 338.84
FL: 338.77
FG: 339.19
FG: 339.29
FG: 338.84
FG: 338.94
5.61%
3.97%
FG: 339.33
20+00
96+00CRYSTAL SPRINGSSTREET NW1.31%
BCR
STA: 19+86.63, 20.06' RT
ELEV: 332.61
ECR
STA: 19+91.78, 25.02' LT
ELEV: 332.78
ECR
STA: 19+96.63, 10.00' RT
ELEV: 332.33
BCR
STA: 20+06.78, 10.00' LT
ELEV: 332.26
CB #14
RIM: 332.13
CB #16
RIM: 332.35
CB #15
RIM: 332.13
1/2Δ
FL: 332.47
1/2Δ
FL: 332.50
FL: 332.65
FL: 332.72
FG: 332.67
FG: 332.57
FG: 332.74
NEAT SAWCUT
AND HOT TAR SEAL
S88° 44' 20"E
521.01'
ROAD C STA: 19+70 =
CRYSTAL SPRINGS ST NW STA: 96+24.76
PROVIDE MONUMENT
STA:19+70.01, 3.00' LT
R10.00'
R15.00'
0+00 S89° 36' 30"E
116.54'N88° 53' 46"E
55.33'
INFLECTION POINT
STA:0+55.33
PROVIDE MONUMENT
STA:0+55.33, 2.50' LT
CB #2
RIM: 335.50
CB #1
RIM: 335.50
NEAT SAWCUT AND
HOT TAR SEAL
BEGIN ROAD A IMPROVEMENTS
STA: 0+35.11, 0.00'
MATCH EXISTING GRADE ELEV: 336.02
CENTER OF CUL-DE-SAC
STA:0+00.00
STA: 0+34.92, 17.50' RT
MATCH EXISTING GRADE ELEV: 336.09
STA: 0+35.30, 17.50' LT
MATCH EXISTING GRADE ELEV: 335.96 FG: 335.94
FG: 336.04
33
6
336
3383
3
7
336
3
3
633633
7
33
8
33
9
1
2
3
4
TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
Know what's below.
before you dig.Call
R
27
STKTDSMTL
4/6/2022
PERMIT SET
2210633.10
P.O.BOX 73790
PUYALLUP, WA 98373-0790
EVAN MANN
COPPER RIDGE, LLC
CRYSTAL SPRINGS
A PORTION OF THE NE 1/4 OF THE NW 1/4 OF SEC. 19, TWN. 17 N., RGE. 02 E. W.M.
CITY OF YELM, THURSTON COUNTY, WASHINGTON.
CRYSTAL SPRINGS
APPLICATION #
DATE: April 6, 2022 FILENAME: Q:\2021\2210633\10_CIV\CAD\_FINAL DESIGN\_2210633-SH-ROAD-DETL.dwg
C3.5
11
INTERSECTION
DETAILS
1 SCALE: 1"=10'
ROAD A & B INTERSECTION
2 SCALE: 1"=10'
ROAD B & C INTERSECTION
R24.00'R24.00'
CONSTRUCTION
CENTERLINE
ROAD C
3 SCALE: 1"=10'
CRYSTAL SPRINGS & ROAD C INTERSECTION
N
GRAPHIC SCALE
0 10 20
1" = 10 FEET
5
4 SCALE: 1"=10'
WOODLAND CT. SE & ROAD A INTERSECTION
ROAD A
WOO
D
L
A
N
D
C
T.
S
E.
04/08/2022
ss
s s3+813+00
ROAD A
S89° 36' 30"E
209.37'
CENTER OF C.D.S.
STA:3+31.08, 18.50' RT
3
3
9338 3383393
3
9 338337337338CB #5
RIM: 336.55
CB #4
RIM: 336.48
BCR
STA: 2+73.25, 18.50' RT
ELEV: 339.32
ECR, BCR
STA: 2+96.20, 33.58' RT
ELEV: 339.20
ECR, BCR
STA: 3+68.24, 26.42' RT
ELEV: 337.05
ECR
STA: 3+76.24, 18.66' RT
ELEV: 336.561/2Δ
FL: 339.20
1/2Δ
FL: 338.63
1/2Δ
FL: 336.87
3/4Δ
FL: 337.811/4Δ
FL: 339.19
1
2
3
4
TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
Know what's below.
before you dig.Call
R
27
STKTDSMTL
4/6/2022
PERMIT SET
2210633.10
P.O.BOX 73790
PUYALLUP, WA 98373-0790
EVAN MANN
COPPER RIDGE, LLC
CRYSTAL SPRINGS
A PORTION OF THE NE 1/4 OF THE NW 1/4 OF SEC. 19, TWN. 17 N., RGE. 02 E. W.M.
CITY OF YELM, THURSTON COUNTY, WASHINGTON.
CRYSTAL SPRINGS
APPLICATION #
DATE: April 6, 2022 FILENAME: Q:\2021\2210633\10_CIV\CAD\_FINAL DESIGN\_2210633-SH-ROAD-DETL.dwg
C3.6
12
CUL-DE-SAC
DETAIL
ASPHALT WEDGE CURB
N
GRAPHIC SCALE
0 10 20
1" = 10 FEET
5
1 SCALE: 1'=10'
CUL-DE-SAC ENLARGEMENT
1
C3.7
PROVIDE PERMANENT BARRICADE 1
C3.9
04/08/2022
1
2
3
4
TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
Know what's below.
before you dig.Call
R
27
STKTDSMTL
4/6/2022
PERMIT SET
2210633.10
P.O.BOX 73790
PUYALLUP, WA 98373-0790
EVAN MANN
COPPER RIDGE, LLC
CRYSTAL SPRINGS
A PORTION OF THE NE 1/4 OF THE NW 1/4 OF SEC. 19, TWN. 17 N., RGE. 02 E. W.M.
CITY OF YELM, THURSTON COUNTY, WASHINGTON.
CRYSTAL SPRINGS
APPLICATION #
DATE: April 6, 2022 FILENAME: Q:\2021\2210633\10_CIV\CAD\_FINAL DESIGN\_2210633-SH-ROAD-DETL.dwg
C3.7
13
ROAD NOTES
AND DETAILS
4"1.0'
SEE NOTE 1
GENERAL NOTES
1.MATERIALS AND CONSTRUCTION REQUIREMENTS
SHALL BE PER LATEST EDITION OF WSDOT STANDARD
SPECIFICATIONS FOR ROAD, BRIDGE, AND MUNICIPAL
CONSTRUCTION UNLESS OTHERWISE NOTED.
PL 6' MIN
FROM PL
DRIVEWAY PORTION OF
SIDEWALK TO BE 6" THICK
6'
20' MAX.
5' SIDEWALK PER CITY OF
YELM DWG NO. 2-11
BACK OF
CURB
6" THICK CEMENT
CONCRETE DRIVEWAY
2%2%
2%
4" CONCRETE
(6" @ DRIVEWAY LOCATIONS)
CEMENT CONCRETE
ROLLED CURB AND GUTTER
5' SIDEWALK 6' LANDSCAPE
1.SEE CITY OF YELM DWG. NO 2-11 FOR ADDITIONAL NOTES & DETAILS
2.MINIMUM CONCRETE DEPTH OF 6" IS REQUIRED AT ALL PROPOSED DRIVEWAY LOCATIONS
NOTES
1.DRIVEWAY LOCATIONS TO BE IDENTIFIED BY
THE CONTRACTOR PRIOR TO POURING THE
SIDEWALKS OR ALL SIDEWALKS SHALL BE 6"
THICK.
NOTES
1 NOT TO SCALE
ASPHALT WEDGE CURB
2 NOT TO SCALE
SIDEWALK DETAIL
3 NOT TO SCALE
DRIVEWAY PLACEMENT
1.ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH CITY
OF YELM STANDARDS, AND THE MOST CURRENT COPY OF THE STATE OF
WASHINGTON STANDARD SPECIFICATIONS FOR ROAD, BRIDGE, AND
MUNICIPAL CONSTRUCTION.
2.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TRAFFIC CONTROL IN
ACCORDANCE WITH MUTCD. PRIOR TO DISRUPTION OF ANY TRAFFIC,
TRAFFIC CONTROL PLANS SHALL BE PREPARED AND SUBMITTED TO THE
CITY FOR APPROVAL. NO WORK SHALL COMMENCE UNTIL ALL APPROVED
TRAFFIC CONTROL IS IN PLACE.
3.ALL CURB AND GUTTER, STREET GRADES, SIDEWALK GRADES, AND ANY
OTHER VERTICAL AND/OR HORIZONTAL ALIGNMENT SHALL BE STAKED BY
AN ENGINEERING OR SURVEYING FIRM CAPABLE OF PERFORMING SUCH
WORK.
4.WHERE NEW ASPHALT JOINS EXISTING, THE EXISTING ASPHALT SHALL BE
CUT TO A NEAT VERTICAL EDGE AND TACKED WITH ASPHALT EMULSION
TYPE CSS-1 IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS. THE
NEW ASPHALT SHALL BE FEATHERED BACK OVER EXISTING TO PROVIDE
FOR A SEAL AT THE SAW CUT LOCATION AND THE JOINT SEALED WITH
GRADE AR-4000W PAVING ASPHALT.
5.COMPACTION OF SUBGRADE, ROCK, AND ASPHALT SHALL BE IN
ACCORDANCE WITH THE STANDARD SPECIFICATIONS.
6.SUBGRADE INSPECTION SHALL BE PERFORMED BY AN APPROVED TESTING
FIRM AND FORMS SHALL BE INSPECTED FOR LINE AND GRADE BY AN
ENGINEER BEFORE POURING CONCRETE.
7.CERTIFICATION AS TO CONFORMANCE SHALL BE PROVIDED TO THE CITY
PRIOR TO ACCEPTANCE OF WORK.
8.THE CONTRACTOR/DEVELOPER SHALL FURNISH AND INSTALL ALL
PERMANENT SIGNING.
GENERAL NOTES (STREET CONSTRUCTION)
04/08/2022
1
2
3
4
TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
Know what's below.
before you dig.Call
R
27
STKTDSMTL
4/6/2022
PERMIT SET
2210633.10
P.O.BOX 73790
PUYALLUP, WA 98373-0790
EVAN MANN
COPPER RIDGE, LLC
CRYSTAL SPRINGS
A PORTION OF THE NE 1/4 OF THE NW 1/4 OF SEC. 19, TWN. 17 N., RGE. 02 E. W.M.
CITY OF YELM, THURSTON COUNTY, WASHINGTON.
CRYSTAL SPRINGS
APPLICATION #
DATE: April 6, 2022 FILENAME: Q:\2021\2210633\10_CIV\CAD\_FINAL DESIGN\_2210633-SH-ROAD-DETL.dwg
C3.8
14
ROAD NOTES
AND DETAILS
04/08/2022
1
2
3
4
TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
Know what's below.
before you dig.Call
R
27
STKTDSMTL
4/6/2022
PERMIT SET
2210633.10
P.O.BOX 73790
PUYALLUP, WA 98373-0790
EVAN MANN
COPPER RIDGE, LLC
CRYSTAL SPRINGS
A PORTION OF THE NE 1/4 OF THE NW 1/4 OF SEC. 19, TWN. 17 N., RGE. 02 E. W.M.
CITY OF YELM, THURSTON COUNTY, WASHINGTON.
CRYSTAL SPRINGS
APPLICATION #
DATE: April 6, 2022 FILENAME: Q:\2021\2210633\10_CIV\CAD\_FINAL DESIGN\_2210633-SH-ROAD-DETL.dwg
C3.9
15
ROAD NOTES
AND DETAILS1NOT TO SCALE
PERMANENT BARRICADE
04/08/2022
APN
22719210404
CITY OF YELM
ss
s ss
s
s
sssssssssssssssssssss
s
s
(STORMFILTER)
50LF 12" PERF CPEP
(MAINTENANCE ACCESS)CRYSTAL SPRINGS ST NWWOODLAND CT SE
ROAD A
ROAD BROAD C
CB #15
RIM: 332.13
CB #14
RIM: 332.13
CB #16
RIM: 332.35
CB #17
RIM: 333.28
CB #13
RIM: 337.57
CB #12
RIM: 337.57
CB #10
RIM: 339.03
CB #9
RIM: 336.74
CB #8
RIM: 336.74
CB #19
RIM: 337.44
CB #20
RIM: 337.70 CB #21
RIM: 337.74
CO #1
RIM: 337.79
CO #2
RIM: 337.60
CO #3
RIM: 337.49
CB #3
RIM: 338.89CB #2
RIM: 335.50
CB #1
RIM: 335.50
CB #5
RIM: 336.55
CB #4
RIM: 336.48
CB #11
RIM: 339.01
SHALLOW GRASS
LINED SWALE
CB #18
RIM: 333.80
(DRYWELL)
PIPE RUN# 13
PIPE RUN# 20
PIPE RUN# 11
PIPE RUN# 21
PIPE RUN# 10
PIPE RUN# 9
PIPE RUN# 8
PIPE RUN# 14
PIPE RUN# 15
PIPE RUN# 18
PIPE RUN# 19
PIPE RUN# 7
PIPE RUN# 6
PIPE RUN# 5
PIPE RUN# 3
PIPE RUN# 2
PIPE RUN# 1
PIPE RUN# 4
PIPE RUN# 17
PIPE RUN# 16
CB #7
RIM: 337.59
CB #6
RIM: 337.58
STRUCTURAL
PAD: 337.04
STRUCTURAL
PAD: 336.21
STRUCTURAL
PAD: 336.30
STRUCTURAL
PAD: 336.57
STRUCTURAL
PAD: 336.86
STRUCTURAL
PAD: 337.13
STRUCTURAL
PAD: 337.41
STRUCTURAL
PAD: 337.63
STRUCTURAL
PAD: 337.32
STRUCTURAL
PAD: 337.16
STRUCTURAL
PAD: 337.86
STRUCTURAL
PAD: 338.35
STRUCTURAL
PAD: 338.82
STRUCTURAL
PAD: 338.84
STRUCTURAL
PAD: 338.40STRUCTURAL
PAD: 337.16
STRUCTURAL
PAD: 337.45
STRUCTURAL
PAD: 337.70
STRUCTURAL
PAD: 337.47 STRUCTURAL
PAD: 338.36
STRUCTURAL
PAD: 337.29
STRUCTURAL
PAD: 337.28
STRUCTURAL
PAD: 335.39
STRUCTURAL
PAD: 336.61
STRUCTURAL
PAD: 337.64
STRUCTURAL
PAD: 338.73
STRUCTURAL
PAD: 339.08 STRUCTURAL
PAD: 338.82 STRUCTURAL
PAD: 337.69
STRUCTURAL
PAD: 336.46
26
18
TRACT A
17
12
16
141113
20
19
9
15
23
6
1
2
3
4
10
7
8
25
21
24
TRACT B
5
29
27
22
30
338 33733628338338338339
33
9338337336336337338339
339
338336337
338
3
3
7
339338338
338
338337337338337338337338
(STORMFILTER)
STORM STRUCTURE TABLE
STRUCTURE NAME
CB #1
TYPE 1
N 596707.80
E 1114895.65
CB #2
TYPE 1
N 596670.37
E 1114896.37
CB #3
48" TYPE 2
N 596669.99
E 1115038.85
CB #4
TYPE 1
N 596667.95
E 1115224.44
CB #5
TYPE 1
N 596705.78
E 1115224.60
CB #6
48" TYPE 2
N 596619.46
E 1115036.99
CB #7
TYPE 1
N 596619.12
E 1115006.69
CB #8
48" TYPE 2
N 596316.71
E 1115046.24
CB #9
TYPE 1
N 596316.01
E 1115009.64
CB #10
48" TYPE 2
N 596208.84
E 1115064.41
CB #11
48" TYPE 2
N 596188.31
E 1115063.94
CB #12
TYPE 1
N 596191.04
E 1114902.39
STRUCTURE DETAILS
RIM = 335.50
IE = 332.60 (12" S)
RIM = 335.50
IE = 332.41 (12" N)
IE = 332.41 (12" E)
RIM = 338.89
IE = 331.70 (12" W)
IE = 331.70 (12" S)
IE = 331.70 (12" E)
RIM = 336.48
IE = 333.51 (12" N)
IE = 333.51 (12" W)
RIM = 336.55
IE = 333.70 (12" S)
RIM = 337.58
IE = 331.45 (12" N)
IE = 331.45 (12" S)
IE = 331.45 (12" W)
RIM = 337.59
IE = 332.69 (12" E)
RIM = 336.74
IE = 330.20 (12" N)
IE = 330.20 (12" N)
IE = 330.20 (12" S)
IE = 330.20 (12" W)
RIM = 336.74
IE = 331.84 (12" E)
RIM = 339.03
IE = 333.64 (12" N)
IE = 333.64 (12" S)
RIM = 339.01
IE = 333.75 (12" W)
IE = 333.75 (12" N)
RIM = 337.57
IE = 334.56 (12" N)
IE = 334.56 (12" E)
STORM STRUCTURE TABLE
STRUCTURE NAME
CB #13
TYPE 1
N 596213.47
E 1114902.88
CB #14
TYPE 1
N 596198.91
E 1114545.03
CB #15
TYPE 1
N 596221.34
E 1114545.53
CB #16
48" STORMFILTER
N 596203.81
E 1114551.71
CB #17
48" TYPE 2
N 596203.15
E 1114585.55
CB #18
48" TYPE 2
DRYWELL
N 596221.42
E 1114690.10
CB #19
TYPE 1
N 596406.13
E 1115070.13
CB #20
72" STORMFILTER
N 596378.97
E 1115067.39
CB #21
48" TYPE 2
N 596378.98
E 1115075.66
CO #1
CO
N 596378.98
E 1115085.67
CO #2
CO
N 596326.82
E 1115085.67
CO #3
CO
N 596326.82
E 1115075.67
STRUCTURE DETAILS
RIM = 337.57
IE = 334.67 (12" S)
RIM = 332.13
IE = 327.80 (12" NE)
RIM = 332.13
IE = 327.93 (12" S)
RIM = 332.35
IE = 327.76 (12" SW)
IE = 327.76 (12" N)
IE = 325.46 (12" E)
RIM = 333.28
IE = 325.46 (12" W)
RIM = 333.80
RIM = 337.44
IE = 334.37 (12" S)
RIM = 337.70
IE = 329.87 (12" S)
IE = 327.57 (12" E)
IE = 329.87 (12" N)
RIM = 337.74
IE = 327.53 (12" W)
IE = 327.53 (12" E)
IE = 327.53 (12" S)
RIM = 337.79
IE = 327.53 (12" W)
IE = 327.53 (12" S)
RIM = 337.60
IE = 327.53 (12" N)
RIM = 337.49
IE = 327.53 (12" N)
PIPE TABLE
NAME
PIPE RUN# 1
PIPE RUN# 2
PIPE RUN# 3
PIPE RUN# 4
PIPE RUN# 5
PIPE RUN# 6
PIPE RUN# 7
PIPE RUN# 8
PIPE RUN# 9
PIPE RUN# 10
PIPE RUN# 11
PIPE RUN# 12
PIPE RUN# 13
PIPE RUN# 14
PIPE RUN# 15
PIPE RUN# 16
PIPE RUN# 17
PIPE RUN# 18
PIPE RUN# 19
PIPE RUN# 20
PIPE RUN# 21
SIZE
12"
12"
12"
12"
12"
12"
12"
12"
12"
12"
12"
12"
12"
12"
12"
12"
12"
12"
12"
12"
12"
LENGTH
36'
139'
183'
36'
47'
27'
299'
34'
105'
17'
159'
21'
16'
61'
23'
3'
8'
50'
51'
30'
5'
SLOPE
0.50%
0.50%
0.98%
0.50%
0.50%
4.09%
0.41%
4.48%
3.14%
0.53%
0.50%
0.50%
0.91%
0.50%
16.49%
0.50%
0.00%
0.00%
0.00%
0.00%
0.44%
MATERIAL
CPEP
CPEP
CPEP
CPEP
CPEP
CPEP
CPEP
CPEP
CPEP
CPEP
CPEP
CPEP
CPEP
CPEP
CPEP
CPEP
CPEP
CPEP
CPEP
CPEP
CPEP
1
2
3
4
TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
Know what's below.
before you dig.Call
R
27
STKTDSMTL
4/6/2022
PERMIT SET
2210633.10
P.O.BOX 73790
PUYALLUP, WA 98373-0790
EVAN MANN
COPPER RIDGE, LLC
CRYSTAL SPRINGS
A PORTION OF THE NE 1/4 OF THE NW 1/4 OF SEC. 19, TWN. 17 N., RGE. 02 E. W.M.
CITY OF YELM, THURSTON COUNTY, WASHINGTON.
CRYSTAL SPRINGS
APPLICATION #
DATE: April 6, 2022 FILENAME: Q:\2021\2210633\10_CIV\CAD\_FINAL DESIGN\_2210633-SH-STRM.dwg
C4.1
16
DRAINAGE AND
STORM PLAN
N
GRAPHIC SCALE
0 40 80
1" = 40 FEET
20
PROPOSED 200 SF X 4FT INFILTRATION TRENCH
SEE SHEET C3.3
PROPOSED 1,040 SF X 4FT
INFILTRATION
TRENCH
ROOF RUNOFF NOTE
ROOF RUNOFF SHALL BE INFILTRATED WITHIN PRIVATE
SYSTEMS LOCATED ON EACH LOT.
10' UTILITY EASEMENT
(TYP)
1
C4.2
1
C4.3
1
C4.3
2
C4.3
2
C4.3
CUT = 3,100 CU. YDS
FILL = 2,600 CU. YDS
NET = 500 CU. YDS EXPORT
NOTE:
THE ABOVE QUANTITIES ARE ESTIMATES ONLY INTENDED FOR
THE PERMITTING PROCESS. DO NOT USE FOR BID PURPOSES.
THE QUANTITIES DO NOT HAVE STRIPPING, COMPACTION, OR
CUT OR FILL ADJUSTMENT FACTORS APPLIED TO THEM, NOR
DO THEY ACCOUNT FOR ROADWAY SECTION.
EARTHWORK QUANTITIES
(PERF.)
(PERF.)
(PERF.)
(PERF.)
PAD GRADE NOTES
1.ALL PAD GRADES SHOWN ARE STRUCTURAL PAD
GRADES.
ON-LOT INFILTRATION TRENCH
SEE SHEET C4.5
(TYP)
04/08/2022
12" PIPE
NATIVE MATERIAL BACKFILL
COMPACT TO 90% OF MAX DENSITY UNDER LANDSCAPED
AREAS AND 95% OF MAX DENSITY UNDER PAVED SURFACES
12" PERF. PIPE
GEOTEXTILE FABRIC
WASHED DRAIN ROCK
NATIVE MATERIAL.
DO NOT COMPACT.
0.0%
52'IE: SEE PLAN
TYPE 2 CATCH BASIN
RIM: PER PLAN
6" PVC PIPE
HS-20 RATED CAP.
RIM: 337.75
6" PERFORATED PVC.
PERFORATIONS SHALL BE
0.25" DIAMETER SPACED
3" ON CENTER.
OBSERVATION WELL
WITH REMOVABLE CAP
LOCATION VARIES. SEE PLAN
12" X12" METAL FOOT PLATE
FINISHED
GRADE
(PER PLAN)
STORM CLEANOUT
RIM PER PLAN
GRADATION NOTES:
1.WASHED DRAIN ROCK SHALL CONFORM TO
WSDOT SPECIFICATION 9-03.12 (5) GRAVEL
BACKFILL FOR DRY WELLS
4'
WASHED DRAIN ROCK,
SEE GRADATION NOTES
12" PERF CPEP @ 0.00% 10' O.C.
IE = 327.53
NATIVE MATERIAL,
DO NOT COMPACT
+/-7 FT (VARIES)
20'
BOTTOM IE: 326.53
TOP IE: 330.53
5'
NATIVE MATERIAL
BACKFILL, COMPACT TO
90% OF MAX DENSITY
WRAP TOP AND SIDES OF
GALLERY WITH GEOTEXTILE
FABRIC MIRAFI 140N OR
APPROVED EQUIVALENT
10'5'
FG: +/- 337.75
1
2
3
4
TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
Know what's below.
before you dig.Call
R
27
STKTDSMTL
4/6/2022
PERMIT SET
2210633.10
P.O.BOX 73790
PUYALLUP, WA 98373-0790
EVAN MANN
COPPER RIDGE, LLC
CRYSTAL SPRINGS
A PORTION OF THE NE 1/4 OF THE NW 1/4 OF SEC. 19, TWN. 17 N., RGE. 02 E. W.M.
CITY OF YELM, THURSTON COUNTY, WASHINGTON.
CRYSTAL SPRINGS
APPLICATION #
DATE: April 6, 2022 FILENAME: Q:\2021\2210633\10_CIV\CAD\_FINAL DESIGN\_2210633-SH-STRM.dwg
C4.2
17
STORM NOTES
AND DETAILS
YELM STORMWATER NOTES
1.THE CONTRACTOR SHALL OBTAIN ALL APPROVALS AND PERMITS REQUIRED BY
THE CITY OF YELM (CITY) PRIOR TO THE START OF CONSTRUCTION. A GRADING
PERMIT FOR STORM POND CONSTRUCTION MAY BE REQUIRED.
2.STORM DRAIN PIPE SHALL BE ON THE WSDOT QUALIFIED PRODUCTS LIST FOR
THE SPECIFICATION LISTED BELOW:
A.PLAIN CONCRETE STORM SEWER PIPE OR REINFORCED CONCRETE STORM SEWER
PIPE PER WSDOT STANDARD SPECIFICATION 9-05.7.
B.SOLID WALL PVC STORM SEWER PIPE PER WSDOT STANDARD SPECIFICATION
9- 05.12(1).
C.DUCTILE IRON SEWER PIPE PER WSDOT STANDARD SPECIFICATION 9-05.13.
D.HANCOR BLUE SEAL ™ AND ADVANCED DRAINAGE SYSTEMS (ADS/HANCOR)
N-12 HDPE AND (ADS/HANCOR) SANITITE UP TO 36” IN DIAMETER PER
WSDOT STANDARD SPECIFICATIONS 9-05.20 AND 9-05.24.
E.CONTECH DUROMAXX STEEL RIB REINFORCED POLYETHYLENE PIPE, IN
DIAMETERS FROM 24 INCH TO 60 INCH PER WSDOT STANDARD SPECIFICATION
9-05.22.
3.ALL STORM DRAINAGE SYSTEMS SHALL BE AIR TESTED AT 4 PSI EXCEPT
CONCRETE PIPE, WHICH SHALL BE TESTED PER WSDOT/APWA STANDARD FOR
CONCRETE STORM PIPE. ALL FLEXIBLE PIPE SHALL BE MANDREL TESTED PER
WSDOT/APWA STANDARDS. TESTING SHALL BE DONE BY THE CONTRACTOR.
4.TESTING OF THE STORM SEWER SHALL INCLUDE VIDEOTAPING OF THE MAIN BY
THE CONTRACTOR. IMMEDIATELY PRIOR TO VIDEOTAPING, ENOUGH WATER SHALL
BE RUN DOWN THE LINE SO IT COMES OUT THE LOWER CATCH BASIN. A COPY OF
THE VIDEO TAPE SHALL BE SUBMITTED TO THE CITY. ACCEPTANCE OF THE LINE
WILL NOT BE MADE UNTIL AFTER THE TAPE HAS BEEN REVIEWED AND APPROVED
BY THE CITY. TESTING SHALL TAKE PLACE AFTER ALL UNDERGROUND UTILITIES
ARE INSTALLED AND COMPACTION OF THE ROADWAY SUBGRADE IS COMPLETE.
5.SPECIAL STRUCTURES, OIL/WATER SEPARATORS AND OUTLET CONTROLS SHALL
BE INSTALLED PER PLANS AND MANUFACTURERS' RECOMMENDATIONS. WHERE
OIL/WATER SEPARATORS ARE CONNECTED TO A SEWER SYSTEM, THEY SHALL BE
INSTALLED WITH A P-TRAP OR CHECK VALVE TO PREVENT ODORS.
6.ALL DISTURBED AREAS SHALL BE STABILIZED IN ACCORDANCE WITH MINIMUM
REQUIREMENT 2 OF THE LATEST EDITION OF THE DEPARTMENT OF ECOLOGY
STORMWATER MANAGEMENT MANUAL FOR WESTERN WASHINGTON (SWMMWW).
FOR SITES WHERE VEGETATION HAS BEEN PLANTED THROUGH HYDRO SEEDING,
THE FINANCIAL GUARANTEE WILL NOT BE RELEASED UNTIL THE VEGETATION HAS
BEEN THOROUGHLY ESTABLISHED.
7.WHERE CONNECTIONS REQUIRE "FIELD VERIFICATION", THE CONTRACTOR SHALL
EXPOSE SUCH CONNECTION POINTS AND FITTINGS 48 HOURS PRIOR TO
DISTRIBUTING SHUTDOWN NOTICES.
8.ANY CHANGES TO THE DESIGN SHALL FIRST BE REVIEWED AND APPROVED BY THE
PROJECT ENGINEER AND THE CITY’S CIVIL REVIEW ENGINEER.
9.ALL STORM PIPE SHALL BE A MINIMUM OF 12-INCH DIAMETER FOR MAINS AND
CROSSINGS. WHEN PRIVATE STORMWATER (I.E. ROOF, LOT OR FOOTING DRAINS)
CANNOT BE INFILTRATED ON INDIVIDUAL LOTS, THE MINIMUM STANDARD PIPING
CONNECTION TO THE PUBLIC SYSTEM SHALL BE 8-INCH PVC. THE 8-INCH MAIN
USED FOR CONNECTION SHALL BEGIN AT THE RIGHT-OF-WAY, AND THE
CONNECTION TO THE CATCH BASIN OR MANHOLE SHALL BE CORED AND GROUTED.
10.ALL STORM MAINS AND RETENTION/DETENTION AREAS SHALL BE STAKED FOR
GRADE AND ALIGNMENT BY AN ENGINEERING OR SURVEY FIRM LICENSED TO
PERFORM SUCH WORK.
11.THE MINIMUM STAKING OF STORM SEWER SYSTEMS SHALL BE IN ACCORDANCE
WITH SECTION 3.00.050 OF THESE STANDARDS, AND AS FOLLOWS:
A.STAKE LOCATION OF ALL CATCH BASINS, MANHOLES AND OTHER FIXTURES FOR
GRADE AND ALIGNMENT.
B.STAKE LOCATION, SIZE, AND DEPTH OF RETENTION/DETENTION FACILITY.
C.STAKE FINISHED GRADE OF ALL STORMWATER FEATURES, INCLUDING BUT NOT
LIMITED TO CATCH BASIN/MANHOLE RIM ELEVATIONS, OVERFLOW STRUCTURES,
WEIRS, AND INVERT ELEVATIONS OF ALL PIPES IN CATCH BASINS, MANHOLES, AND
PIPES THAT DAYLIGHT.
12.PIPE MATERIALS USED FOR STORMWATER CONVEYANCE SHALL BE AS APPROVED
BY THE CITY. PIPE SIZE, SLOPE, COVER, ETC., SHALL BE AS SPECIFIED IN THE CITY
OF YELM DEVELOPMENT GUIDELINES AND ENGINEERING STANDARDS.
13.ALL DRIVEWAY CULVERTS SHALL BE OF SUFFICIENT LENGTH TO PROVIDE A
MINIMUM 3:1 SLOPE FROM THE EDGE OF THE DRIVEWAY TO THE BOTTOM OF THE
DITCH. CULVERTS SHALL HAVE BEVELED END SECTIONS TO MATCH THE SIDE
SLOPE.
14.IF DRAINAGE OUTLETS (STUB-OUTS) ARE TO BE PROVIDED FOR EACH INDIVIDUAL
LOT, THE STUB OUTS SHALL CONFORM TO THE FOLLOWING:
A.EACH OUTLET SHALL BE LOCATED AT THE LOWEST ELEVATION ON THE LOT, TO
SERVICE ALL FUTURE ROOF DOWNSPOUTS AND FOOTING DRAINS, DRIVEWAYS,
YARD DRAINS, AND ANY OTHER SURFACE OR SUBSURFACE. EACH OUTLET SHALL
HAVE FREE-FLOWING, POSITIVE DRAINAGE TO AN APPROVED STORM WATER
CONVEYANCE SYSTEM OR TO AN APPROVED OUTFALL LOCATION.
B.OUTLETS ON EACH LOT SHALL BE LOCATED WITH A 5-FOOT HIGH, 2"X 4" STAKE
MARKED "STORM" OR "DRAIN." THE STUB-OUT SHALL VISIBLY EXTEND ABOVE
SURFACE LEVEL AND BE SECURED TO THE STAKE.PIPE MATERIAL SHALL BE AS
APPROVED BY THE CITY.
C.DRAINAGE EASEMENTS ARE REQUIRED FOR DRAINAGE SYSTEMS DESIGNED TO
CONVEY FLOWS THROUGH INDIVIDUAL LOTS.
D.THE DEVELOPER AND/OR CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE
LOCATIONS OF ALL STUB-OUT CONVEYANCE LINES WITH RESPECT TO THE
UTILITIES
E.POWER, GAS, TELEPHONE, TELEVISION). ALL INDIVIDUAL STUB-OUTS SHALL BE
PRIVATELY OWNED AND MAINTAINED BY THE LOT HOMEOWNER.
15.THE STORM DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO
APPROVED PLANS ON FILE WITH THE CITY. ANY MATERIAL DEVIATION FROM THE
APPROVED PLANS WILL REQUIRE WRITTEN APPROVAL FROM THE CITY.
16.ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR SIMILARLY
STABILIZED TO THE SATISFACTION OF THE CITY. FOR SITES WHERE GRASS HAS
BEEN PLANTED THROUGH HYDRO SEEDING, THE PERFORMANCE BOND WILL NOT
BE RELEASED UNTIL THE GRASS HAS BEEN THOROUGHLY ESTABLISHED, UNLESS
OTHERWISE APPROVED BY THE CITY.
17.ALL BUILDING DOWNSPOUTS ON COMMERCIAL SITES SHALL BE CONNECTED TO
THE STORM DRAINAGE SYSTEM, UNLESS OTHERWISE APPROVED BY THE CITY.
18.ALL EROSION CONTROL AND STORMWATER FACILITIES SHALL BE REGULARLY
INSPECTED AND MAINTAINED BY THE CONTRACTOR DURING THE CONSTRUCTION
PHASE OF THE DEVELOPMENT PROJECT.
19.NO FINAL CUT OR FILL SLOPE SHALL EXCEED TWO (2) HORIZONTAL TO ONE (1)
VERTICAL WITHOUT STABILIZATION BY ROCKERY OR BY A STRUCTURAL RETAINING
WALL.
20.THE PROJECT ENGINEER SHALL VERIFY THE LOCATIONS, WIDTHS, THICKNESSES,
AND ELEVATIONS OF ALL EXISTING PAVEMENTS AND STRUCTURES, INCLUDING
UTILITIES AND OTHER FRONTAGE IMPROVEMENTS, THAT ARE TO INTERFACE WITH
NEW WORK, AND PROVIDE ALL TRIMMING, CUTTING, SAW CUTTING, GRADING,
LEVELING, SLOPING, COATING, AND OTHER WORK, INCLUDING MATERIALS
NECESSARY TO CAUSE THE INTERFACE WITH EXISTING WORKS TO BE PROPER,
WITHOUT CONFLICT, ACCEPTABLE TO THE PROJECT ENGINEER AND THE CITY’S
CIVIL REVIEW ENGINEER, COMPLETE IN PLACE, AND READY TO USE.
21.COMPACTION OF ALL FILL AREAS SHALL BE PER CURRENT APWA SPECIFICATIONS.
FILL SHALL BE PROVIDED IN 6" MAXIMUM LIFTS AND SHALL BE COMPACTED TO 95
PERCENT OF ITS MAXIMUM RELATIVE DENSITY.
1 NOT TO SCALE
INFILTRATION SECTION
04/08/2022
1
2
3
4
TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
Know what's below.
before you dig.Call
R
27
STKTDSMTL
4/6/2022
PERMIT SET
2210633.10
P.O.BOX 73790
PUYALLUP, WA 98373-0790
EVAN MANN
COPPER RIDGE, LLC
CRYSTAL SPRINGS
A PORTION OF THE NE 1/4 OF THE NW 1/4 OF SEC. 19, TWN. 17 N., RGE. 02 E. W.M.
CITY OF YELM, THURSTON COUNTY, WASHINGTON.
CRYSTAL SPRINGS
APPLICATION #
DATE: April 6, 2022 FILENAME: Q:\2021\2210633\10_CIV\CAD\_FINAL DESIGN\_2210633-SH-STRM.dwg
C4.3
18
STORM NOTES
AND DETAILS
1 NOT TO SCALE
72 IN STORMFILTER (CB #20)
2 NOT TO SCALE
48 IN STORMFILTER (CB #16)
04/08/2022
1
2
3
4
TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
Know what's below.
before you dig.Call
R
27
STKTDSMTL
4/6/2022
PERMIT SET
2210633.10
P.O.BOX 73790
PUYALLUP, WA 98373-0790
EVAN MANN
COPPER RIDGE, LLC
CRYSTAL SPRINGS
A PORTION OF THE NE 1/4 OF THE NW 1/4 OF SEC. 19, TWN. 17 N., RGE. 02 E. W.M.
CITY OF YELM, THURSTON COUNTY, WASHINGTON.
CRYSTAL SPRINGS
APPLICATION #
DATE: April 6, 2022 FILENAME: Q:\2021\2210633\10_CIV\CAD\_FINAL DESIGN\_2210633-SH-STRM.dwg
C4.4
19
STORM NOTES
AND DETAILS
CAP AT END
7-3/4"
15"
8"
7"
PACKING
45° (1/8)
BEND
2-7/8"
2'-0"10"
8-3/4"
1-1/4"
1/2"2"
9"
1"
1"
FIBRE JOINT4"1. PIPE MATERIAL AS SPECIFIED
BY THE ENGINEER.
2. PIPE DIAMETER AS SHOWN
5/8"
1'-0"
NOTES:
1/2"
PER PLAN.
RAISE - 1/2" WIDE BORDER
PROVIDE COUPLINGS &
REDUCERS AS NECESSARY
3000 PSI CLASS C
CONCRETE (TYP.)
(LANDSCAPE AREAS
ONLY)
NOTE
BACKFILL MATERIAL SHALL NOT HAVE PARTICLE SIZE
GREATER THAN 1" WITHIN 6" OF THE PIPE OR THE
CONTRACTOR HAS THE OPTION TO USE GRAVEL BACKFILL
PIPE ZONE BEDDING CONFORMING TO W.S.D.O.T. 9-03.12 (3).
6" PVC
FRAME AND VANED GRATE
RECTANGULAR ADJUSTMENT SECTION
3"4" MI
N. (
T
Y
P.)
34"
5"
#3 BAR EACH WAY
SEE NOTE 1
NOTES:
1.AS ACCEPTABLE ALTERNATIVES TO THE REBAR
SHOWN IN THE PRECAST BASE SECTION,
FIBERS (PLACED ACCORDING TO THE
STANDARD SPECIFICATIONS), OR WIRE MESH
HAVING A MINIMUM AREA OF 0.12 SQUARE
INCHES PER FOOT SHALL BE USED WITH THE
MINIMUM REQUIRED REBAR SHOWN IN THE
ALTERNATIVE PRECAST BASE SECTION. WIRE
MESH SHALL NOT BE PLACED IN THE
KNOCKOUTS.
2.THE KNOCKOUT DIAMETER SHALL NOT BE
GREATER THAN 20". KNOCKOUTS SHALL HAVE
A WALL THICKNESS OF 2" MINIMUM TO 2.5"
MAXIMUM. PROVIDE A 1.5" MINIMUM GAP
BETWEEN THE KNOCKOUT WALL AND THE
OUTSIDE OF THE PIPE. AFTER THE PIPE IS
INSTALLED, FILL THE GAP WITH JOINT MORTAR
IN ACCORDANCE WITH STANDARD
SPECIFICATION 9-04.3.
3.THE MAXIMUM DEPTH FROM THE FINISHED
GRADE TO THE LOWEST PIPE INVERT SHALL BE
5'.
4.THE FRAME AND GRATE MAY BE INSTALLED
WITH THE FLANGE UP OR DOWN. THE FRAME
MAY BE CAST INTO THE ADJUSTMENT SECTION.
5.THE PRECAST BASE SECTION MAY HAVE A
ROUNDED FLOOR, AND THE WALLS MAY BE
SLOPED AT A RATE OF 1:24 OR STEEPER.
6.THE OPENING SHALL BE MEASURED AT THE
TOP OF THE PRECAST BASE SECTION.
7.ALL PICKUP HOLES SHALL BE GROUTED FULL
AFTER THE BASIN HAS BEEN PLACED.
#3 BAR EACH
CORNER
#3 BAR EACH
CORNER
18" MIN.
26"(SEE
N
O
T
E
6)
22
"
(S
E
E
N
O
T
E
6
)4"44"21" MIN.24"
30
"
20
"
5"
6" OR 12"
ONE #3 BAR HOOP
FOR 6" HEIGHT
TWO #3 BAR HOOPS
FOR 12" HEIGHT
ALTERNATIVE PRECAST BASE SECTION
#3 BAR EACH SIDE
SECTION B-B
#3 BAR
HOOP
*CORRUGATED POLYETHYLENE
STORM SEWER PIPE
PIPE ALLOWANCES
PIPE MATERIAL MAXIMUM INSIDE
DIAMETER
REINFORCED OR PLAIN
CONCRETE 12"
ALL METAL PIPE 15"
CPSSP*
(STD. SPEC. 9-05.20)12"
SOLID WALL PVC
(STD. SPEC. 9-05.12(1))15"
PROFILE WALL PVC
(STD. SPEC. 9-05.12(2))15"
NOTE:
1.NO STEPS ARE REQUIRED WHEN HEIGHT IS 4' OR LESS.
2.THE BOTTOM OF THE PRECAST CATCH BASIN MAY BE SLOPED TO FACILITATE
CLEANING.
3.THE RECTANGULAR FRAME AND GRATE MAY BE INSTALLED WITH THE FLANGE UP
OR DOWN. THE FRAME MAY BE CAST INTO THE ADJUSTMENT SECTION.
4.KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM.
PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE
OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN
ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3.
SEPARATE BASE
PRECAST
INTEGRAL BASE
PRECAST WITH RISER
6"24" MIN.12"MAX.1" MIN2.5" MAX.12"(TYP.)15' - 0" MAX. (FOR MAINTENANCE)6"12"
REINFORCED STEEL (TYP.)
GRAVEL BACKFILL FOR
PIPE ZONE BEDDING
STEPS OR
LADDER
MORTAR FILLET
MORTAR (TYP.)
48", 54", 60", 72", 84" OR 96"
FLAT SLAB TOP
RECTANGULAR ADJUSTMENT SECTION
OR CIRCULAR ADJUSTMENT SECTION
HAND HOLD
28" MAX.4" MIN.16" MAX.CATCH BASIN FRAME AND VANED GRATE
OR MANHOLE RING AND COVER
PIPE ALLOWANCES
CATCH
BASIN
DIAMETE
R
PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER
CONCRETE ALL
METAL CPSSP SOLID
WALL PVC
PROFILE
WALL PVC
48"24"30"24"27"30"
54"30"36"30"27"36"
60"36"42"36"36"42"
72"42"54"42"36"48"
84"54"60"54"36"48"
96"60"72"60"36"48"
CORRUGATED POLYETHYLENE STORM SEWER PIPE (STD. SPEC. 9-05.20)
(STD. SPEC. 9-05.12(1))
(STD. SPEC. 9-05.12(2))
1 2 3
1
2
3
CATCH BASIN DIMENSIONS
CATCH
BASIN
DIAMETER
WALL
THICKNES
S
BASE
THICKNES
S
MAXIMUM
KNOCKOUT
SIZE
MINIMUM
DISTANCE
BETWEEN
KNOCKOUT
S
48"4"6"36"8"
54"4.5"8"42"8"
60"5"8"48"8"
72"6"8"60"12"
84"8"12"72"12"
96"8"12"84"12"6"0D6" MIN
FLEXIBLERIGID
(DI, CONC)
TRENCH WIDTH PER WSDOT 2-09.40.5 x OD(CPEP, CMP, PVC)
BACKFILL UTILITY TRENCHES WITHIN
PAVED AREAS WITH BANKRUN
GRAVEL PER WSDOT 9-03.19.
COMPACT TO A MINIMUM OF 95%
UNLESS NOTED OTHERWISE IN
PROJECT SPECIFICATIONS.
TRENCHES MAY BE BACKFILLED WITH
NATIVE MATERIAL AND COMPACTED
TO 90% IN UNPAVED AREAS.
PIPE BEDDING PER
W.S.D.O.T. 9-03.12(3), 95%
COMPACTION
PIPE AS SPECIFIED
ON PLAN OR SPECS
SUBGRADE ELEVATION
1 NOT TO SCALE
STORM CLEANOUT 2 NOT TO SCALE
STORM TRENCH SECTION
3 NOT TO SCALE
TYPE 1 CATCH BASIN 4 NOT TO SCALE
TYPE 2 CATCH BASIN
04/08/2022
1
2
3
4
TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
Know what's below.
before you dig.Call
R
27
STKTDSMTL
4/6/2022
PERMIT SET
2210633.10
P.O.BOX 73790
PUYALLUP, WA 98373-0790
EVAN MANN
COPPER RIDGE, LLC
CRYSTAL SPRINGS
A PORTION OF THE NE 1/4 OF THE NW 1/4 OF SEC. 19, TWN. 17 N., RGE. 02 E. W.M.
CITY OF YELM, THURSTON COUNTY, WASHINGTON.
CRYSTAL SPRINGS
APPLICATION #
DATE: April 6, 2022 FILENAME: Q:\2021\2210633\10_CIV\CAD\_FINAL DESIGN\_2210633-SH-STRM.dwg
C4.5
20
ON LOT
INFILTRATION
PROPERTY LINE
PROPERTY LINEPROPERTY LINER.O.W. LINE5.0' SIDEYARD SETBACK
STRUCTURE
DRIVEWAY
DRAIN TO STREET
INFILTRATION
TRENCH
SEDIMENT CONTROL
STRUCTURE
INSTALL CLEANOUT AT ALL 90° BENDS
4" PVC PIPE
@ 1.0% MIN.
15' HOUSE SETBACK
10.0' UTILITY EASEMENT
25.0' REAR
YARD
SETBACK
10.0' TRENCH
SETBACK
NOTE:
TRENCH SHOWN IS SCHEMATIC. FINAL LOCATION AND
CONFIGURATION TO BE CONFIRMED WITH EACH BUILDING PERMIT.
*ON-LOT INFILTRATION NOTE:
INFILTRATION TRENCHES MAY BE PLACED IN FILL MATERIAL IF THE FILL IS
PLACED AND COMPACTED UNDER THE DIRECT SUPERVISION OF A
GEOTECHNICAL ENGINEER OR PROFESSIONAL CIVIL ENGINEER WITH
GEOTECHNICAL EXPERTISE, AND IF THE MEASURED INFILTRATION RATE IS AT
LEAST 8 INCHES PER HOUR. INFILTRATION RATES CAN BE TESTED USING THE
METHODS DESCRIBED IN APPENDIX III-A OF THE 2015 PIERCE COUNTY
STORMWATER MANAGEMENT AND SITE DEVELOPMENT MANUAL.
10'
TRENCH
SETBACK
GEOTEXTILE FABRIC
4.5' MAX.
3.0' MIN.
2.0' MIN.
10.0' MAX.
4" PERF PIPE @ 0.0% SLOPE
CENTERED IN TRENCH
WASHED ROCK
1 1/2" - 3/4"
WASHED ROCK TO EXTEND
TO EXISTING GRADE
INFILTRATABLE SOILS.
DEPTHS MAY VARY
NOTES:
1.TRENCH LENGTH AND WIDTH SHALL BE CALCULATED TO PROVIDE
MINIMUM REQUIRED BOTTOM AREA PER TRENCH SIZE TABLE.
2.THE PERFORATIONS SHALL BE CIRCULAR AND A MINIMUM 1/2" DIAMETER.
3.PERFORATIONS SHALL BE CLEANLY CUT AND BE SMOOTH AND UNIFORM
WITH NO EXCESS MATERIAL LEFT FROM THE HOLE PERFORATIONS
PROCESS.
4.THERE SHALL BE A MINIMUM OF 7 SETS OF PERFORATIONS WITH 2 HOLES
PER SET OF PERFORATIONS FOR EACH 3.5' OF PIPE LENGTH.
5.RUBBER GASKETS OR GROUTING OF THE JOINTS FOR PERFORATED PIPE
RUNS WILL NOT BE REQUIRED.
6.INSPECTION OF THE PERFORATED PIPE SHALL BE MADE BY THE
MUNICIPALITY BEFORE INSTALLATION OF THE PIPE IN THE GROUND.
7.REFER TO ON-LOT INFILTRATION NOTE ON THIS SHEET.
8.PERFORATED PIPE SHALL NOT EXCEED 5.0' MAXIMUM DEPTH TO INVERT
FOR RESIDENTIAL SEDIMENT CONTROL STRUCTURE.
TRENCH SIZE
IMPERVIOUS PROPOSED (SF)BOTTOM AREA REQUIRED (SF)
1,000 30
1,500 45
2,000 60
2,500 75
3,000 90
ON 50' WIDE LOTS, A MAXIMUM TRENCH LENGTH OF 30' IS ALLOWED IN ORDER
TO ACCOMMODATE 10' SETBACKS. TRENCH WIDTH MAY VARY TO PROVIDE
REQUIRED BOTTOM AREA.
THIS TABLE SHOULD BE USED TO SIZE TRENCHES ON ALL LOTS. AN
INFILTRATION RATE OF 20 INCHES PER HOUR WAS USED TO DETERMINE THESE
DIMENSIONS, PER THE GEOTECHNICAL REPORT.
EXTEND TRENCH
BOTTOM TO
NATIVE SOIL*
*
1 NOT TO SCALE
TYPICAL INFILTRATION TRENCH DIAGRAM
2 NOT TO SCALE
INFILTRATION TRENCH
3 NOT TO SCALE
SEDIMENT CONTROL STRUCTURE
04/08/2022
ROAD A
ss
s sssssssssss
N0° 53' 46"E509.25'3+810+00
1+00 2+00 3+00
STA:0+45.03, 6.10' RT
CONNECT TO EXISTING 4" C900 WATER MAIN
1 - 4"X8" ADAPTER (MJ)
1 - 8" 22.5° BEND (MJ)
CONC. THRUST BLOCKING
STA:0+56.33, 5.00' LT
1 - 8" 45° BEND (MJ)
CONC. THRUST BLOCKING
STA:1+76.74, 5.00' LT
1 - 8" TEE (MJ)
3 - 8" GATE VALVE (MJ)
CONC. THRUST BLOCKING
STA:2+71.82, 5.00' LT
1 - 8"X6" TEE (MJxFL)
2 - 8" GATE VALVE (MJ)
1 - 6" GATE VALVE (FL)
11 LF 8" DI CL52
1 - FIRE HYDRANT ASSEMBLY
SEE YELM DWG. 4-7 SHEET C5.3
CONC. THRUST BLOCKING
STA:3+76.00, 5.00' LT
END 8" C900 MAIN
1 - 8" GATE VALVE (MJxFL)
1 - 8" CAP (FL)
CONC. THRUST BLOCKING
STA:2+71.93, 22.04' RT
CENTER OF HYDRANT ASSEMBLY
SEE YELM DWG 4-7 SHEET C5.3
120 LF 8"
C900 PVC
95 LF 8"
C900 PVC
100 LF 8"
C900 PVC
STA:0+64.59, 21.44' LT
5
8" SINGLE METER SERVICE
SEE WATER NOTE #1
STA:1+36.52, 20.50' LT
5
8" DUAL METER SERVICE
SEE WATER NOTE #2
STA:2+16.52, 20.50' LT
5
8" DUAL METER SERVICE
SEE WATER NOTE #2
STA:2+96.52, 20.50' LT
5
8" DUAL METER SERVICE
SEE WATER NOTE #2 STA:3+64.58, 22.39' LT
5
8" SINGLE METER SERVICE
SEE WATER NOTE #1
STA:3+40.65, 57.61' RT
5
8" DUAL METER SERVICE
SEE WATER NOTE #2
1817
12
16
14
11 13
19
15
10
21
325
330
335
340
345
325
330
335
340
345
0+00FG FG0+50FG 335.98FG 336.261+00FG 336.93FG 337.681+50FG 338.43FG 339.162+00FG 339.68FG 339.942+50FG 339.96FG 339.733+00FG 339.25FG 338.543+50FG 337.79FG 337.0411 LF 8" PVC C900 WATER MAIN
STA: 45.03, 6.10' RT
CONNECT TO EXISTING 4" C900 WATER MAIN
1 - 4"X8" ADAPTER (MJ)
1 - 8" 22.5° BEND (MJ)
CONC. THRUST BLOCKING
STA: 1+76.74, 5.00' LT
1 - 8" TEE (MJ)
3 - 8" GATE VALVE (MJ)
CONC. THRUST BLOCKING
STA: 2+71.82, 5.00' LT
1 - 8"X6" TEE (MJXFL)
2 -8" GATE VALVE (MJ)
1 - 6" GATE VALVE (FL)
15 LF 6" DI CL52
1 - FIRE HYDRANT ASSEMBLY
CONC. THRUST BLOCKING
STA: 3+76.00, 5.00' LT
END 8" PVC C900 WATER MAIN
1 - 8" GATE VALVE (MJXFL)
1 - 8" CAP (FL)
CONC. THRUST BLOCKING
0.50%
3.00
%
3.00%
150' VC
PVI: 341.11
PVI STA: 2+39.26
K: 25.00
BVCS: 1+64.26BVCE: 338.86EVCS: 3+14.26EVCE: 338.86HI PT: 2+39.23ELEV: 339.9850' VC
PVI: 335.87
PVI STA: 0+64.54
K: 14.29
BVCS: 0+39.54BVCE: 336.00EVCS: 0+89.54EVCE: 336.62LOW PT: 0+46.69ELEV: 335.9895 LF 8" C900 PVC
100 L
F
8
"
C
9
0
0
P
V
C
42" MIN
120 LF
8
"
C
9
0
0
P
V
C
18" MIN
STA: 0+56.33, 5.00' LT
1 - 8" 45° BEND (MJ)
CONC. THRUST BLOCKING
s
s
ss
sssss
51+00 52+00
STA:50+31.50, 5.00' LT
1 - 8" TEE (MJ)
3 - 8" GATE VALVE (MJ)
CONC. THRUST BLOCKING
STA:51+94.72, 5.00' LT
END 8" MAIN
1 - 8" GATE VALVE (MJxFL)
1 - 8" CAP (FL)
CONC. THRUST BLOCKING
STA:51+11.18, 17.94' RT
5
8" SINGLE METER SERVICE
SEE WATER NOTE #1
STA:51+85.53, 15.53' RT
5
8" DUAL METER SERVICE
SEE WATER NOTE #2
STA:51+86.76, 19.52' LT
5
8" DUAL METER SERVICE
SEE WATER NOTE #2
ROAD B26
6
3
4
25
24
5
29
27
30 28
TRACT B
163 LF 8" C900 PVC
327
330
335
340
327
330
335
340
50+00FG 337.74FG 337.7550+50FG 337.68FG 337.6051+00FG 337.88FG 338.1651+50FG 338.45FG 338.7352+00FG 339.0112" STORM CROSSING
PROPOSED 2" FORCE MAIN
SEE SHEET C6.1
42" MIN
18" MIN
1.2'
SEPARATION
28'
REDUCED
SEPARATION
SECTION
STA: 50+31.50, 5.00' LT
1 - 8" TEE (MJ)
3 - GATE VALVE (MJ)
CONC. THRUST BLOCKING
STA: 51+91.72
END 8" MAIN
1 - 8" GATE VALVE (MJxFL)
1 - 8" CAP (FL)
CONC. THRUST BLOCKING
163 LF 8" C90
0
P
V
C
1
2
3
4
TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
Know what's below.
before you dig.Call
R
27
STKTDSMTL
4/6/2022
PERMIT SET
2210633.10
P.O.BOX 73790
PUYALLUP, WA 98373-0790
EVAN MANN
COPPER RIDGE, LLC
CRYSTAL SPRINGS
A PORTION OF THE NE 1/4 OF THE NW 1/4 OF SEC. 19, TWN. 17 N., RGE. 02 E. W.M.
CITY OF YELM, THURSTON COUNTY, WASHINGTON.
CRYSTAL SPRINGS
APPLICATION #
DATE: April 5, 2022 FILENAME: Q:\2021\2210633\10_CIV\CAD\_FINAL DESIGN\_2210633-SH-WATR-ROAD A.dwg
C5.1
21
ROAD A & TRACT B
WATER PLAN AND
PROFILE
N
GRAPHIC SCALE
0 30 60
1" = 30 FEET
15
ROAD A PROFILE
SCALE: H:1" = 30', V:1" = 3'
1.SEE CITY OF YELM DWG. NO. 4-1 ON SHEET C5.3 FOR 5 8"
SINGLE METER SERVICE.
2.SEE CITY OF YELM DWG. NO. 4-2 ON SHEET C5.3 FOR 5 8" DUAL
METER SERVICE.
WATER NOTES
PROPOSED 12" STORM
SEE SHEET C3.1
EXISTING 4"
C900 MAIN
PROPOSED 2" FORCE MAIN
SEE SHEET C6.1
FINISHED GRADE ELEVATION
AT CONSTRUCTION CENTERLINE
EXISTING GRADE ELEVATION
AT CONSTRUCTION CENTERLINE
FINISHED GRADE AT
CONSTRUCTION
CENTERLINE
EXISTING GRADE AT
CONSTRUCTION CENTERLINE
FINISHED GRADE ELEVATION
AT CONSTRUCTION CENTERLINE
EXISTING GRADE ELEVATION
AT CONSTRUCTION CENTERLINE
FINISHED GRADE AT
CONSTRUCTION
CENTERLINEEXISTING GRADE AT
CONSTRUCTION CENTERLINE
TRACT B (SHARED ACCESS) PROFILE
SCALE: H:1" = 30', V:1" = 3'
04/08/2022
TRACT A
14
9
15
23
61234
10
7 8
25 2124
5
ROAD B
22
ss
sssss ss ss
ssss
ssssss1+002+00STA:10+12.45, 4.98' RT
CONNECT TO EXISTING 12" PVC
WATER MAIN POTHOLE TO CONFIRM
DEPTH AND LOCATION PRIOR TO
WATER MAIN CONSTRUCTION.
SEE YELM DWG. 4-10 ON SHEET C5.3
STA:10+27.79, 5.00' RT
1 - 8"X6" TEE (MJxFL)
2 - 8" GATE VALVE (MJ)
1 - 6" GATE VALVE (FL)
11 LF 8" DI CL52
1 - FIRE HYDRANT ASSEMBLY
SEE YELM DWG. 4-7 SHEET C5.3
CONC. THRUST BLOCKING
STA:12+10.89, 5.00' RT
1 - 8" TEE (MJ)
1 - 8" GATE VALVE (MJ)
CONC. THRUST BLOCKING
STA:10+27.58, 16.26' RT
CENTER FIRE HYDRANT ASSEMBLY
SEE YELM DWG. 4-7 ON SHEET C5.3
STA:14+93.98, 5.00' RT
1 - 8" TEE (MJ)
1 - 8" GATE VALVE (MJ)
CONC. THRUST BLOCKING
STA:14+43.82, 13.94' LT
5
8" SINGLE METER SERVICE
SEE WATER NOTE #1
STA:14+39.78, 13.94' RT
5
8" SINGLE METER SERVICE
SEE WATER NOTE #1
STA:13+62.83, 19.81' LT
5
8" DUAL METER SERVICE
SEE WATER NOTE #2
STA:13+58.50, 20.50' RT
5
8" DUAL METER SERVICE
SEE WATER NOTE #2
STA:12+78.50, 20.50' RT
5
8" DUAL METER SERVICE
SEE WATER NOTE #2
STA:12+82.83, 19.81' LT
5
8" DUAL METER SERVICE
SEE WATER NOTE #2
STA:12+02.83, 19.81' LT
5
8" DUAL METER SERVICE
SEE WATER NOTE #2
STA:11+22.83, 19.81' LT
5
8" DUAL METER SERVICE
SEE WATER NOTE #2
STA:10+36.15, 13.94' LT
5
8" SINGLE METER SERVICE
SEE WATER NOTE #1
15 LF 8" C900 PVC WATER MAIN
183 LF C900 PVC
WATER MAIN
280 LF C900 PVC
WATER MAIN
11+00 12+00 13+00 14+00
325
330
335
340
345
350
325
330
335
340
345
350
9+82.99FG 10+00FG 339.04FG 338.5410+50FG 338.04FG 337.5611+00FG 337.28FG 337.2311+50FG 337.39FG 337.5712+00FG 337.74FG 337.9212+50FG 338.09FG 338.2713+00FG 338.44FG 338.6213+50FG 338.66FG 338.4614+00FG 338.13FG 338.0114+50FG 338.30FG 338.8015+00FG 15+20.62FG0.70%
1.32%
2.00%2.00%
PVI: 338.79
PVI STA: 13+50.01
K: 24.80
50' VC
BVCS: 13+25.01BVCE: 338.62EVCS: 13+75.01EVCE: 338.46HI PT: 13+42.37ELEV: 338.68PVI: 337.04
PVI STA: 11+00.00
K: 26.00
70' VC
BVCS: 10+64.90BVCE: 337.74EVCS: 11+35.10EVCE: 337.29LOW PT: 11+16.90ELEV: 337.22PVI: 337.80
PVI STA: 14+25.16
K: 15.08
50' VC
BVCS: 14+00.16BVCE: 338.13EVCS: 14+50.16EVCE: 338.30LOW PT: 14+20.00ELEV: 338.00STA: 10+12.45, 4.98' RT
CONNECT TO EXISTING 12" PVC
WATER MAIN POTHOLE TO CONFIRM
DEPTH AND LOCATION PRIOR TO
WATER MAIN CONSTRUCTION.
SEE YELM DWG. 4-10 ON SHEET C5.3
STA: 10+27.79, 5.00' RT
1 - 8"X6" TEE (MJxFL)
2 - 8" GATE VALVE (MJ)
1 - 6" GATE VALVE (FL)
11 LF 8" DI CL52
1 - FIRE HYDRANT ASSEMBLY
SEE YELM DWG. 4-7 SHEET C5.3
CONC. THRUST BLOCKING
STA: 12+10.89, 5.00'RT
1 - 8" TEE (MJ)
1 - 8" GATE VALVE (MJ)
CONC. THRUST BLOCKING
STA: 14+93.98, 5.00' RT
1 - 8" TEE (MJ)
1 - 8" GATE VALVE (MJ)
CONC. THRUST BLOCKING
42" MIN
18" MIN
1
2
3
4
TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
Know what's below.
before you dig.Call
R
27
STKTDSMTL
4/6/2022
PERMIT SET
2210633.10
P.O.BOX 73790
PUYALLUP, WA 98373-0790
EVAN MANN
COPPER RIDGE, LLC
CRYSTAL SPRINGS
A PORTION OF THE NE 1/4 OF THE NW 1/4 OF SEC. 19, TWN. 17 N., RGE. 02 E. W.M.
CITY OF YELM, THURSTON COUNTY, WASHINGTON.
CRYSTAL SPRINGS
APPLICATION #
DATE: April 6, 2022 FILENAME: Q:\2021\2210633\10_CIV\CAD\_FINAL DESIGN\_2210633-SH-WATR-ROAD B.dwg
C5.2
22
ROAD B WATER
PLAN AND PROFILENGRAPHIC SCALE
0 30 60
1" = 30 FEET
15
ROAD B PROFILE
SCALE: H:1" = 30', V:1" = 3'
1.SEE CITY OF YELM DWG. NO. 4-1 ON SHEET C5.3 FOR 5 8"
SINGLE METER SERVICE.
2.SEE CITY OF YELM DWG. NO. 4-2 ON SHEET C5.3 FOR 5 8" DUAL
METER SERVICE.
WATER NOTES
PROPOSED 2" FORCE MAIN
SEE SHEET C6.2
PROPOSED 12" STORM
SEE SHEET C3.2
15 LF 8" C900 PVC
183 LF 8" C900 PVC
280 LF 8" C900 PVC
04/08/2022
1
2
3
4
TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
Know what's below.
before you dig.Call
R
27
STKTDSMTL
4/6/2022
PERMIT SET
2210633.10
P.O.BOX 73790
PUYALLUP, WA 98373-0790
EVAN MANN
COPPER RIDGE, LLC
CRYSTAL SPRINGS
A PORTION OF THE NE 1/4 OF THE NW 1/4 OF SEC. 19, TWN. 17 N., RGE. 02 E. W.M.
CITY OF YELM, THURSTON COUNTY, WASHINGTON.
CRYSTAL SPRINGS
APPLICATION #
DATE: March 21, 2022 FILENAME: Q:\2021\2210633\10_CIV\CAD\_FINAL DESIGN\_2210633-SH-WATR-DETL.dwg
C5.3
23
WATER NOTES AND
DETAILS
1.ALL WORKMANSHIP AND MATERIAL SHALL BE IN ACCORDANCE WITH CITY OF YELM
STANDARDS AND THE MOST CURRENT COPY OF THE STATE OF WASHINGTON
STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION.
2.ALL WORK IN CITY RIGHT-OF-WAY REQUIRES A PERMIT FROM THE CITY OF YELM.
PRIOR TO ANY WORK COMMENCING, THE GENERAL CONTRACTOR SHALL ARRANGE
FOR A PRECONSTRUCTION MEETING TO BE ATTENDED BY ALL MAJOR CONTRACTORS,
REPRESENTATIVES OF INVOLVED UTILITIES, AND THE CITY OF YELM. THE
CONTRACTOR IS RESPONSIBLE TO HAVE A SET OF APPROVED PLANS AT THE
MEETING.
3.WATER MAINS SHALL MEET THE FOLLOWING SPECIFICATIONS:
3.1.POLYVINYL CHLORIDE (PVC) PIPE (UNDER 4 INCHES): PIPE MATERIAL SHALL BE
PVC 1120, PVC 1220, OR PVC 2120, AND HAVE MINIMUM WALL THICKNESS EQUAL
TO OR LESS THAN THE STANDARD DIMENSION RATIO (SDR) OF 21, AND MEET THE
REQUIREMENTS OF WSDOT STANDARD SPECIFICATIONS SECTION 9-30.1(5)B.
3.2.POLYVINYL CHLORIDE (PVC) PIPE (4 THROUGH 12 INCHES): SHALL MEET THE
REQUIREMENTS OF AWWA C900, CLASS 150 WALL THICKNESS EQUAL TO OR
GREATER THAN THE SDR OF 18, AND MEET THE REQUIREMENTS OF WSDOT
STANDARD SPECIFICATIONS SECTION 9-30.1(5)A.
3.3.POLYVINYL CHLORIDE (PVC) PIPE (14 THROUGH 20 INCHES): SHALL MEET THE
REQUIREMENTS OF AWWA C905 WALL THICKNESS EQUAL TO OR GREATER THAN
THE SDR OF 18.
3.4.DUCTILE IRON PIPE (DIP): DIP SHALL CONFORM TO AWWA C151 CLASS 50 OR
GREATER, AND SHALL BE 1/16-INCH CEMENT LINED AND SEALED IN ACCORDANCE
WITH ANSI/AWWA C104/A21.4-90, AND MEET THE REQUIREMENTS OF WSDOT
STANDARD SPECIFICATIONS SECTION 9- 30.2.(1). SIX-INCH FIRE HYDRANT SPOOLS
SHALL BE CLASS 52.
4.GATE VALVES SHALL BE RESILIENT WEDGE, NRS (NON RISING STEM) WITH O-RINGS
SEALS. VALVE ENDS SHALL BE MECHANICAL JOINT OR ANSI FLANGES. VALVES SHALL
CONFORM TO AWWA 509-80. VALVES SHALL BE MUELLER, M & H, KENNEDY, CLOW R/W
OR WATEROUS SERIES 500. EXISTING VALVES TO BE OPERATED BY CITY EMPLOYEES
ONLY.
5.HYDRANTS SHALL BE M & H RELIANT STYLE 929, MUELLER CENTURION, OR CLOW
MEDALLION OR AVK. HYDRANTS SHALL BE BAGGED UNTIL SYSTEM IS APPROVED.
6.ALL LINES SHALL BE CHLORINATED AND TESTED IN CONFORMANCE WITH THE ABOVE
REFERENCED SPECIFICATION (NOTE 1).
7.ALL PIPE AND SERVICES SHALL BE INSTALLED WITH CONTINUOUS TRACER TAPE
INSTALLED 12" TO 18" UNDER THE FINAL GROUND SURFACE. THE MARKER SHALL BE
PLASTIC NON-BIODEGRADABLE, METAL CORE OR BACKING MARKED WATER
2-INCH-WIDE MINIMUM, WHICH CAN BE DETECTED BY A STANDARD METAL DETECTOR.
TAPE SHALL BE TERRA TAPE "D" OR APPROVED EQUAL. IN ADDITION TO TRACER TAPE,
INSTALL 14 GAUGE HEAVY DUTY DIRECT BURY COATED COPPER WIRE (PAIGE "UF"
SINGLE CONDUCTOR OR EQUAL), WRAPPED AROUND THE PIPE, BROUGHT UP AND
TIED OFF AT VALVE BODY. ALL WIRE CONNECTIONS SHALL USE WIRE NUTS AND A DBR
SPLICE KIT, MANUFACTURED BY 3-M OR APPROVED EQUAL. ALL LOCATOR WIRE FOR
SERVICE PIPE SHALL BE CONNECTED TO THE LOCATOR WIRE ON THE WATER MAIN.
8.PROVIDE TRAFFIC CONTROL PLAN(S) AS REQUIRED IN ACCORDANCE WITH MUTCD.
9.ALL WATER MAINS SHALL BE STAKED FOR GRADES AND ALIGNMENT BY AN
ENGINEERING OR SURVEYING FIRM CAPABLE OF PERFORMING SUCH WORK.
10.ALL SERVICE LINE LOCATIONS SHALL BE MARKED ON THE FACE OF THE CURB WITH AN
EMBOSSED "W" 1/4 INCH INTO CONCRETE.
11.CALL UNDERGROUND LOCATE AT 1-800-424-5555 A MINIMUM OF 48 HOURS PRIOR TO
ANY EXCAVATIONS.
12.THE CITY WILL BE GIVEN 72 HOURS NOTICE PRIOR TO SCHEDULING A SHUTDOWN.
WHERE CONNECTIONS REQUIRE "FIELD VERIFICATION", CONNECTION POINTS WILL BE
EXPOSED BY CONTRACTOR AND FITTINGS VERIFIED 48 HOURS PRIOR TO
DISTRIBUTING SHUT-DOWN NOTICES.
13.AT ANY CONNECTION TO AN EXISTING LINE WHERE A NEW VALVE IS NOT INSTALLED,
THE EXISTING VALVE MUST BE PRESSURE TESTED TO CITY STANDARDS PRIOR TO
CONNECTION. IF AN EXISTING VALVE FAILS TO PASS THE TEST, THE CONTRACTOR
SHALL MAKE THE NECESSARY PROVISIONS TO TEST THE NEW LINE PRIOR TO
CONNECTION TO THE EXISTING SYSTEM OR INSTALL A NEW VALVE.
14.AFTER COMPLETION OF ALL ITEMS SHOWN ON THESE PLANS AND BEFORE
ACCEPTANCE OF THE PROJECT, THE CONTRACTOR SHALL OBTAIN A “PUNCH LIST”
PREPARED BY THE CITY’S INSPECTOR DETAILING REMAINING ITEMS OF WORK TO BE
COMPLETED. ALL ITEMS OF WORK SHOWN ON THESE PLANS SHALL BE COMPLETED TO
THE SATISFACTION OF THE CITY PRIOR TO ACCEPTANCE OF THE WATER SYSTEM AND
PROVISION OF WATER SERVICE.
15.A COPY OF THESE APPROVED PLANS AND APPLICABLE CITY DEVELOPER
SPECIFICATIONS AND DETAILS SHALL BE ONSITE DURING CONSTRUCTION.
16.ANY REVISIONS MADE TO THESE PLANS MUST BE REVIEWED BY THE DEVELOPER’S
ENGINEER AND THE CITY OF YELM PRIOR TO ANY IMPLEMENTATION IN THE FIELD. THE
CITY SHALL NOT BE RESPONSIBLE FOR ANY ERRORS AND/OR OMISSIONS ON THESE
PLANS.
GENERAL NOTES (WATER MAIN INSTALLATION)
04/08/2022
1
2
3
4
TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
Know what's below.
before you dig.Call
R
27
STKTDSMTL
4/6/2022
PERMIT SET
2210633.10
P.O.BOX 73790
PUYALLUP, WA 98373-0790
EVAN MANN
COPPER RIDGE, LLC
CRYSTAL SPRINGS
A PORTION OF THE NE 1/4 OF THE NW 1/4 OF SEC. 19, TWN. 17 N., RGE. 02 E. W.M.
CITY OF YELM, THURSTON COUNTY, WASHINGTON.
CRYSTAL SPRINGS
APPLICATION #
DATE: March 21, 2022 FILENAME: Q:\2021\2210633\10_CIV\CAD\_FINAL DESIGN\_2210633-SH-WATR-DETL.dwg
C5.4
24
WATER NOTES AND
DETAILS
04/08/2022
ROAD A
ss
s sssssssssss
N0° 53' 46"E509.25'3+810+00 1+00 2+00 3+00
STA:0+70.78, 5.00' RT
1 - 2" 22.5° BEND
CONC. THRUST BLOCKING
STA:1+67.00, 5.02' RT
1 - 2" TEE
3 - 2" GATE VALVE
CONC. THRUST BLOCKING
STA:3+54.96, 5.00' RT
END 2" FORCE MAIN
PROVIDE END OF LINE
CLEANOUT PER YELM DWG
5-20 ON SHEET C6.4
STA:0+34.39, 19.31' RT
CONNECT TO EXISTING 2" FORCE MAIN
CONTRACTOR TO VERIFY DEPTH AND
LOCATION PRIOR TO CONSTRUCTION
STA:0+96.52, 20.49' LT
2" DUAL SERVICE CONNECTION
SEE SEWER NOTE #2
STA:1+76.52, 20.50' LT
2" DUAL SERVICE CONNECTION
SEE SEWER NOTE #2
STA:2+56.52, 20.50' LT
2" DUAL SERVICE CONNECTION
SEE SEWER NOTE #2
STA:3+36.52, 20.50' LT
2" DUAL SERVICE CONNECTION
SEE SEWER NOTE #2
STA:3+08.10, 52.53' RT
1" SINGLE SERVICE CONNECTION
SEE SEWER NOTE #1
STA:3+64.41, 42.08' RT
1" SINGLE SERVICE
CONNECTION SEE SEWER
NOTE #1
39 LF 2" SDR 21 PVC
96LF 2" SDR 21 PVC
188 LF 2" SDR 21 PVC
18
17
12
16
141113
19
15
10 21
3383383
3
9338337336
338337338338336 337 338 3393373
3
6338
325
330
335
340
345
325
330
335
340
345
0+00FG FG0+50FG 335.98FG 336.261+00FG 336.93FG 337.681+50FG 338.43FG 339.162+00FG 339.68FG 339.942+50FG 339.96FG 339.733+00FG 339.25FG 338.543+50FG 337.79FG 337.040.50%
3.00
%
3.00%
150' VC
PVI: 341.11
PVI STA: 2+39.26
K: 25.00
BVCS: 1+64.26BVCE: 338.86EVCS: 3+14.26EVCE: 338.86HI PT: 2+39.23ELEV: 339.9850' VC
PVI: 335.87
PVI STA: 0+64.54
K: 14.29
BVCS: 0+39.54BVCE: 336.00EVCS: 0+89.54EVCE: 336.62LOW PT: 0+46.69ELEV: 335.98STA: 0+34.39, 19.31' RT
CONNECT TO EXISTING 2" FORCE MAIN
CONTRACTOR TO VERIFY DEPTH AND
LOCATION PRIOR TO CONSTRUCTION
STA: 0+70.78, 5.00' RT
1 - 2" 22.5° BEND
CONC. THRUST BLOCKING
STA: 3+54.96, 5.00' RT
END 2" FORCE MAIN
PROVIDE END OF LINE
CLEANOUT PER YELM DWG
5-20 ON SHEET C6.4
STA: 1+67.00, 5.02' RT
1 - 2" TEE
3 - 2" GATE VALVE
CONC. THRUST BLOCKING
18" MIN ROAD Bs
s
ss
sssss
s
52+26
51+00 52+00STA:50+21.49, 7.47' RT
1 - 2" TEE
3 - 2" GATE VALVE
CONC. THRUST BLOCKING
STA:52+19.38, 7.50' RT
END 2" FORCE MAIN
PROVIDE END OF LINE
CLEANOUT PER YELM DWG
5-20 ON SHEET C6.4
STA:51+45.52, 15.32' RT
2" DUAL SERVICE CONNECTION
SEE SEWER NOTE #2
STA:51+55.54, 22.02' LT
1" SINGLE SERVICE CONNECTION
SEE SEWER NOTE #1
STA:52+15.80, 21.84' LT
1" SINGLE SERVICE CONNECTION
SEE SEWER NOTE #1
26
6
3
4
25
24
TRACT B5
29
27
30
28
198 LF 2" SDR 21 PVC33733833833833
8
STA:52+13.04, 18.05' RT
1" SINGLE SERVICE CONNECTION
SEE SEWER NOTE #1
327
330
335
340
327
330
335
340
50+00FG 337.6150+50FG 338.0251+00FG 338.4751+50FG 338.7252+00FG 337.68FGFG 338.31FG 338.45FG 338.0518" MIN
PROPOSED 8" WATER MAIN
SEE SHEET C5.1
STA: 50+21.49, 7.47' RT
1 - 2" TEE
3 - 2" GATE VALVE
CONC. THRUST BLOCKING
12" STORM CROSSING
STA: 51+80.85, 7.53' RT
END 2" FORCE MAIN
PROVIDE END OF LINE
CLEANOUT PER YELM DWG
5-20 ON SHEET C6.4
198LF 2" SDR
2
1
P
V
C
1
2
3
4
TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
Know what's below.
before you dig.Call
R
27
STKTDSMTL
4/6/2022
PERMIT SET
2210633.10
P.O.BOX 73790
PUYALLUP, WA 98373-0790
EVAN MANN
COPPER RIDGE, LLC
CRYSTAL SPRINGS
A PORTION OF THE NE 1/4 OF THE NW 1/4 OF SEC. 19, TWN. 17 N., RGE. 02 E. W.M.
CITY OF YELM, THURSTON COUNTY, WASHINGTON.
CRYSTAL SPRINGS
APPLICATION #
DATE: April 6, 2022 FILENAME: Q:\2021\2210633\10_CIV\CAD\_FINAL DESIGN\_2210633-SH-SSWR-ROAD A.dwg
C6.1
25
ROAD A & TRACT B
SEWER PLAN AND
PROFILE
N
GRAPHIC SCALE
0 30 60
1" = 30 FEET
15
ROAD A PROFILE
SCALE: H:1" = 30', V:1" = 3'
1.SEE CITY OF YELM DWG. NO. 5-1 ON SHEET C6.3 FOR 1" SINGLE
SERVICE CONNECTION.
2.SEE CITY OF YELM DWG. NO. 5-2 ON SHEET C6.3 FOR 2" DOUBLE
SERVICE CONNECTION.
SEWER NOTES
SEWER STEP MAIN SIZING
ROAD A STA: 1+67 - 3+55
NUMBER OF PUMP CORES CONNECTED:8
MAX. PUMP CORES RUNNING
SIMULTANEOUSLY (TABLE 3):3
PROPOSED STEP MAIN SIZE:2" SDR 21
FLOW VELOCITY (TABLE 5):2.92 fps
FRICTION HEAD LOSS (TABLE 5):1.54 FT/100FT
ROAD A STA 0+34 - 1+67
NUMBER OF PUMP CORES CONNECTED:30
MAX. PUMP CORES RUNNING
SIMULTANEOUSLY (TABLE 3):5
PROPOSED STEP MAIN SIZE:2" SDR 21
FLOW VELOCITY (TABLE 5):4.87 fps
FRICTION HEAD LOSS (TABLE 5):3.97 FT/100FT
TRACT 'B'
NUMBER OF PUMP CORES CONNECTED:5
MAX. PUMP CORES RUNNING
SIMULTANEOUSLY (TABLE 3):3
PROPOSED STEP MAIN SIZE:2" SDR 21
FLOW VELOCITY (TABLE 5):2.92 fps
FRICTION HEAD LOSS (TABLE 5):1.54 FT/100FT
FINISHED GRADE ELEVATION
AT CONSTRUCTION CENTERLINE
EXISTING GRADE ELEVATION
AT CONSTRUCTION CENTERLINE
FINISHED GRADE AT
CONSTRUCTION
CENTERLINE
EXISTING GRADE AT
CONSTRUCTION CENTERLINE
TRACT B (SHARED ACCESS) PROFILE
SCALE: H:1" = 30', V:1" = 3'
*FORCE MAIN DESIGN PERFORMED USING RECOMMENDATIONS IN THE
'DESIGN HANDBOOK FOR LOW PRESSURE SEWER SYSTEMS' PREPARED BY
ENVIRONMENT ONE.
PROPOSED 8" WATER MAIN
PROPOSED 12" STORM
FINISHED GRADE ELEVATION
AT CONSTRUCTION CENTERLINE
EXISTING GRADE ELEVATION
AT CONSTRUCTION CENTERLINE
FINISHED GRADE AT
CONSTRUCTION
CENTERLINE
EXISTING GRADE AT
CONSTRUCTION CENTERLINE
39LF 2" SDR 21 PVC 96LF 2" SDR 21
P
V
C
188LF 2" SDR 21 PVC
04/08/2022
ROAD B
ss
sssss ss ss
ssss
ssssss1+002+0011+00 12+00 13+00 14+00
STA:10+78.87, 5.00' LT
END 2" FORCE MAIN
PROVIDE END OF LINE
CLEANOUT PER YELM DWG
5-20 ON SHEET C6.4
STA:11+98.39, 5.00' LT
1 - 2" TEE
3 - 2" GATE VALVE
CONC. THRUST BLOCKING
STA:14+84.23, 5.00' LT
1 - 2" TEE
3 - 2" GATE VALVE
CONC. THRUST BLOCKING
STA:14+02.83, 20.50' LT
2" DUAL SERVICE CONNECTION
SEE SEWER NOTE #2
STA:13+98.50, 20.50' RT
2" DUAL SERVICE CONNECTION
SEE SEWER NOTE #2
STA:13+18.50, 20.50' RT
2" DUAL SERVICE CONNECTION
SEE SEWER NOTE #2
STA:13+22.83, 20.50' LT
2" DUAL SERVICE CONNECTION
SEE SEWER NOTE #2
STA:12+42.83, 20.50' LT
2" DUAL SERVICE CONNECTION
SEE SEWER NOTE #2
STA:12+28.35, 21.57' RT
1" SINGLE SERVICE CONNECTION
SEE SEWER NOTE #1
STA:11+62.83, 20.50' LT
2" DUAL SERVICE CONNECTION
SEE SEWER NOTE #2
STA:10+82.83, 20.50' LT
2" DUAL SERVICE CONNECTION
SEE SEWER NOTE #2
337
337
337338
339339338
338
338
338
33
7 3373383
3
8
339339338339339
338
TRACT B 338TRACT A
14
13
9
15
23
6
1 2 3 4 1078
25 2124
5
22
325
330
335
340
345
350
325
330
335
340
345
350
9+82.99 10+00FG 339.04FG 338.4510+50FG 338.04FG 337.5611+00FG 337.28FG 337.2311+50FG 337.39FG 337.5712+00FG 337.74FG 337.9212+50FG 338.09FG 338.2713+00FG 338.44FG 338.6213+50FG 338.66FG 338.4614+00FG 338.13FG 338.0114+50FG 338.30FG 338.8015+00FG 338.8515+20.62FG 338.970.70%
1.32%
2.00%2.00%
PVI: 338.79
PVI STA: 13+50.01
K: 24.80
50' VC
BVCS: 13+25.01BVCE: 338.62EVCS: 13+75.01EVCE: 338.46HI PT: 13+42.37ELEV: 338.68PVI: 337.04
PVI STA: 11+00.00
K: 26.00
70' VC
BVCS: 10+64.90BVCE: 337.74EVCS: 11+35.10EVCE: 337.29LOW PT: 11+16.90ELEV: 337.22PVI: 337.80
PVI STA: 14+25.16
K: 15.08
50' VC
BVCS: 14+00.16BVCE: 338.13EVCS: 14+50.16EVCE: 338.30LOW PT: 14+20.00ELEV: 338.00PROPOSED 8" WATER MAIN
SEE SHEET C5.2
PROPOSED 12" STORM
SEE SHEET C3.2
STA: 10+78.87, 5.00' RT
END 2" FORCE MAIN
PROVIDE END OF LINE
CLEANOUT PER YELM DWG
5-20 ON SHEET 6.4
STA: 11+98.39, 5.00' RT
1 -2" TEE
3 - 2" GATE VALVE
CONC. THRUST BLOCKING
STA: 14+84.23, 5.00' LT
1 - 2" TEE
3 - 2" GATE VALVE
CONC. THRUST BLOCKING
1
2
3
4
TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
Know what's below.
before you dig.Call
R
27
STKTDSMTL
4/6/2022
PERMIT SET
2210633.10
P.O.BOX 73790
PUYALLUP, WA 98373-0790
EVAN MANN
COPPER RIDGE, LLC
CRYSTAL SPRINGS
A PORTION OF THE NE 1/4 OF THE NW 1/4 OF SEC. 19, TWN. 17 N., RGE. 02 E. W.M.
CITY OF YELM, THURSTON COUNTY, WASHINGTON.
CRYSTAL SPRINGS
APPLICATION #
DATE: April 6, 2022 FILENAME: Q:\2021\2210633\10_CIV\CAD\_FINAL DESIGN\_2210633-SH-SSWR-ROAD B.dwg
C6.2
26
ROAD B SEWER
PLAN AND PROFILENGRAPHIC SCALE
0 30 60
1" = 30 FEET
15
ROAD B PROFILE
SCALE: H:1" = 30', V:1" = 3'
1.SEE CITY OF YELM DWG. NO. 5-1 ON SHEET C6.3 FOR 1" SINGLE
SERVICE CONNECTION.
2.SEE CITY OF YELM DWG. NO. 5-2 ON SHEET C6.3 FOR 2" DOUBLE
SERVICE CONNECTION.
SEWER NOTES
SEWER STEP MAIN SIZING
ROAD B STA: 10+78 - 11+98
NUMBER OF PUMP CORES CONNECTED:4
MAX. PUMP CORES RUNNING
SIMULTANEOUSLY (TABLE 3):3
PROPOSED STEP MAIN SIZE:2"
FLOW VELOCITY (TABLE 5I):2.92 fps
FRICTION HEAD LOSS (TABLE 5):1.54 FT/100FT
ROAD B STA: 11+98 - 14+84
NUMBER OF PUMP CORES CONNECTED:20
PUMP CORES RUNNING
SIMULTANEOUSLY (TABLE 3):5
PROPOSED STEP MAIN SIZE:2"
FLOW VELOCITY (TABLE 5I):4.87 fps
FRICTION HEAD LOSS (TABLE 5):3.97 FT/100FT
*FORCE MAIN DESIGN PERFORMED USING
RECOMMENDATIONS IN THE 'DESIGN HANDBOOK FOR
LOW PRESSURE SEWER SYSTEMS' PREPARED BY
ENVIRONMENT ONE.
FINISHED GRADE AT
CONSTRUCTION CENTERLINE
EXISTING GRADE AT
CONSTRUCTION CENTERLINE
FINISHED GRADE ELEVATION
AT CONSTRUCTION CENTERLINE
EXISTING GRADE ELEVATION
AT CONSTRUCTION CENTERLINE
04/08/2022
1
2
3
4
TEL FAX www.ahbl.comWEBTELFAXwww.ahbl.comWEBTELFAXwww.ahbl.comWEB
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
Know what's below.
before you dig.Call
R
27
STKTDSMTL
4/6/2022
PERMIT SET
2210633.10
P.O.BOX 73790
PUYALLUP, WA 98373-0790
EVAN MANN
COPPER RIDGE, LLC
CRYSTAL SPRINGS
A PORTION OF THE NE 1/4 OF THE NW 1/4 OF SEC. 19, TWN. 17 N., RGE. 02 E. W.M.
CITY OF YELM, THURSTON COUNTY, WASHINGTON.
CRYSTAL SPRINGS
APPLICATION #
DATE: March 21, 2022 FILENAME: Q:\2021\2210633\10_CIV\CAD\_FINAL DESIGN\_2210633-SH-SSWR-DETL.dwg
C6.3
27
SEWER NOTES AND
DETAILS
1.ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH CITY OF YELM
STANDARDS AND THE MOST CURRENT COPY OF THE STATE OF WASHINGTON STANDARD
SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION (WSDOT/APWA).
2.ALL APPROVALS AND PERMITS REQUIRED BY THE CITY OF YELM SHALL BE OBTAINED BY THE
CONTRACTOR PRIOR TO THE START OF CONSTRUCTION.
3.IF CONSTRUCTION IS TO TAKE PLACE IN THE CITY RIGHT-OF-WAY, THE CONTRACTOR SHALL
NOTIFY THE CITY AND OBTAIN ALL THE REQUIRED APPROVALS AND PERMITS.
4.A PRECONSTRUCTION MEETING SHALL BE HELD WITH THE CITY OF YELM PRIOR TO THE START
OF CONSTRUCTION.
5.THE CITY OF YELM SHALL BE NOTIFIED A MINIMUM OF 48 HOURS IN ADVANCE OF A TAP
CONNECTION TO AN EXISTING MAIN. A CITY REPRESENTATIVE SHALL BE PRESENT AT THE TIME
OF THE TAP.
6.THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE LOCATION AND PROTECTION OF ALL
EXISTING UTILITIES. THE CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO
CONSTRUCTION BY CALLING THE UNDERGROUND LOCATE LINE AT 1-800-424-5555 A MINIMUM
OF 48 HOURS PRIOR TO ANY EXCAVATION.
7.SIDE SEWER SERVICES SHALL BE PVC, ASTM D 3034 SDR 35 WITH FLEXIBLE GASKETED OR
SOLVENT WELD JOINTS.
8.ALL PLASTIC PIPE AND SERVICES SHALL BE INSTALLED WITH CONTINUOUS TRACER TAPE,
INSTALLED 12" TO 18" UNDER THE PROPOSED SUBGRADE. THE MARKER SHALL BE PLASTIC
NON-BIODEGRADABLE, METAL CORE OR BACKING MARKED "SEWER" WHICH CAN BE DETECTED
BY A STANDARD METAL DETECTOR. IN ADDITION, STEP SYSTEMS AND FORCE MAINS SHALL BE
INSTALLED WITH 14 GAUGE, HEAVY COATED UF DIRECT BURY COPPER WIRE WRAPPED AROUND
ALL PLASTIC PIPE, BROUGHT UP AND TIED OFF AT VALVE BODY. TAPE SHALL BE TERRA TAPE "D"
OR APPROVED EQUAL. THE TAPE AND WIRE SHALL BE FURNISHED BY THE CONTRACTOR.
9.ALL BURIED POWER FOR STEP SYSTEMS SHALL BE INSTALLED WITH CONTINUOUS TRACER TAPE
INSTALLED 12 ABOVE THE BURIED POWER. THE MARKER SHALL BE PLASTIC
NON-BIODEGRADABLE, METAL CORE BACKING MARKED “POWER”. TAPE SHALL BE FURNISHED
BY CONTRACTOR.
10.BEDDING OF THE SEWER MAIN AND ALL APPURTENANCES SHALL BE SAND AND COMPACTION
OF THE BACKFILL MATERIAL SHALL BE REQUIRED IN ACCORDANCE WITH THE ABOVE
MENTIONED SPECIFICATION (SEE GENERAL NOTE 5.60-A).
11.TEMPORARY STREET PATCHING SHALL BE ALLOWED FOR AS APPROVED BY THE CITY ENGINEER.
TEMPORARY STREET PATCHING SHALL BE PROVIDED BY PLACEMENT AND COMPACTION OF 2
INCH MINIMUM ASPHALT CONCRETE COLD MIX. CONTRACTOR SHALL BE RESPONSIBLE FOR
MAINTENANCE AS REQUIRED.
12.EROSION CONTROL MEASURES SHALL BE TAKEN BY THE CONTRACTOR DURING CONSTRUCTION
TO PREVENT INFILTRATION OF EXISTING AND PROPOSED STORM DRAINAGE FACILITIES AND
ROADWAYS.
13.PROVIDE TRAFFIC CONTROL PLAN(S) IN ACCORDANCE WITH THE MANUAL ON UNIFORM
TRAFFIC CONTROL DEVICES (MUTCD) AS REQUIRED.
14.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO HAVE A COPY OF THESE APPROVED
PLANS ON CONSTRUCTION SITE AT ALL TIMES.
15.ANY CHANGES TO THE DESIGN SHALL FIRST BE REVIEWED AND APPROVED BY THE CITY OF
YELM.
16.ALL STEP MAINS SHALL BE HYDROSTATICALLY TESTED IN CONFORMANCE WITH THE
ABOVE-REFERENCED SPECIFICATION FOR TESTING WATER MAINS. (SEE NOTE 1.) IN ADDITION,
ALL STEP MAINS SHALL BE PIGGED/CLEANED IN THE PRESENCE OF THE CITY INSPECTOR PRIOR
TO PLACING STEP MAIN IN SERVICE.
17.PRIOR TO BACKFILL ALL MAINS AND APPURTENANCES SHALL BE INSPECTED AND APPROVED
BY THE CITY OF YELM. APPROVAL SHALL NOT RELIEVE THE CONTRACTOR FOR CORRECTION OF
ANY DEFICIENCIES AND/OR FAILURES AS DETERMINED BY SUBSEQUENT TESTING AND
INSPECTIONS. IT SHALL BE THE CONTRACTOR’S RESPONSIBILITY TO NOTIFY THE CITY OF YELM
FOR THE REQUIRED INSPECTIONS.
18.PUMP CONTROL PANELS SHALL BE LOCATED ON GARAGE WALL OR REMOTE POST, 5- FEET FROM
TOP OF PANEL TO FINISH GRADE, UNLESS OTHERWISE AUTHORIZED BY THE CITY OF YELM.
19.IN THE EVENT THAT THE DEPARTMENT OF LABOR AND INDUSTRIES OR THE CITY SHOULD
REQUIRE A SEPARATE "ON-OFF" SWITCH CONTROLLING POWER TO THE PUMP CONTROL PANEL,
SAID SWITCH SHALL HAVE A LOCKING COVER MODEL # 5031-0 RAYNTITE SINGLE GANG
WEATHERPROOF COVER 1.406" DIAMETER.
20.INSPECTIONS FOR ONSITE STEP INSTALLATIONS ARE REQUIRED. A 48 HOUR NOTICE TO THE
SEWER DEPARTMENT IS REQUIRED PRIOR TO THE INSPECTION.
ITEMS NEEDING INSPECTION ARE:
20.1.TANK INSTALLATION, IE; BEDDING AND LOCATION
20.2.TANK INFILTRATION, EXFILTRATION TEST
20.3.S.S. PRESSURE TEST
20.4.SERVICE LINE PRESSURE TEST
20.5.FINAL INSPECTION
21.ALL POSTS USED TO SUPPORT PUMP CONTROL PANELS, MUST BE HOT DIP GALVANIZED
UNISTRUT OR APPROVED EQUAL.
GENERAL NOTES (SANITARY SEWER MAIN INSTALLATION)
04/08/2022