Loading...
PSE FINAL 105098738 MOUNTAIN MEADOWSN Vicinity Map 46.9591, -122.6274 Owner / Developer Contact Info officeATTN: COPPER RIDGE, LLC PO BOX 73790 PUYALLUP, WA 98373 EVAN MANN 253.820.7835 THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) PSE No No No Yes Yes Yes No YesDeveloper "Flagging Required" "Outages Required" "Locates Required" ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.) EROSION & SEDIMENT CONTROL REQUIREMENTS NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES (LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING 0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE & ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. GAS PHONE CABLE TV 511877253 105098738 N/A 105099610 N/A N/A N/A N/A N/A N/A N/A N/A 511877256 107061200 N/A 106381322 N/A N/A PROJECT PHASE PWR NOTIF#ORDER# Superior St. Lights Relocation Removal Temporary Job Order Distribution Service Stubs HP Svc/MSA 10. 9. 8. 7. 6. 5. 4. 3. 2. 1.THE CUSTOMER IS RESPONSIBLE FOR PROVIDING ALL TRENCHING, PER THE TRENCH PROFILE, AND ALL EXCAVATIONS AT THE TRANSFORMER/HANDHOLE VAULT SITES SUCH THAT PSE FACILITIES WILL MATCH FINAL GRADE. VAULT HOLES WILL HAVE STABLE LEVEL BOTTOMS. CUSTOMER WILL PROVIDE 6" OF CRUSHED ROCK FOR VAULT BEDDING. ALL TRENCHES WILL HAVE 6" OF WASHED SAND COVER AND 4" BEDDING FOR ALL CONDUITS. THE CUSTOMER WILL PROVIDE SELECT BACKFILL, IF REQUIRED, AND COMPACTION AS NECESSARY. THE CUSTOMER IS RESPONSIBLE FOR DISPOSAL OF ALL NATIVE SPOILS NOT SUITABLE FOR USE AS BACKFILL. ALL TRENCHES MAY BE JOINT WITH GAS, TELEPHONE AND TV CABLE. ALL CABLES/CONDUITS TO BE INSTALLED IN CUSTOMER'S TRENCH AT THE DEPTH INDICATED IN TRENCH DETAIL (DEPENDENT UPON SIZE OF CONDUIT BEING INSTALLED TO MEET MIN 36" OF COVER). INSTALL CABLE ID TAGS AT EACH END OF THE PRIMARY CABLES PER THE CIRCUIT ONE-LINE DIAGRAM. UNLESS OTHERWISE SPECIFIED BY MUNICIPALITIES, INSTALL PVC (DB-120) ROAD CROSSINGS AS INDICATED ON THE CROSSINGS CONDUIT TABLE & AS SHOWN ON WORK SKETCH. CROSSINGS SHALL BE INSTALLED BY CUSTOMER/DEVELOPER PER PUGET SOUND ENERGY STANDARDS. AT SYMBOL: INSTALL UNDERGROUND PRIMARY CABLES IN CONDUIT. CABLE LENGTH AND CONDUIT SIZE AS INDICATED ON PRIMARY CABLE & CONDUIT TABLE. AT SYMBOL: INSTALL 600 VOLT UG SECONDARY CABLES IN CONDUIT. CABLE/CONDUIT SIZE AND LENGTH AS INDICATED ON SECONDARY CABLE & CONDUIT TABLE. AT SYMBOL: INSTALL MINI-PAD HANDHOLE & PADMOUNT TRANSFORMER. ADDITIONAL EQUIPMENT AS INDICATED ON VAULT TABLE. AT SYMBOL: INSTALL SECONDARY PEDESTAL/HANDHOLE W/ (3) MULTI-CONNECTORS. SIZE AS INDICATED ON SECONDARY HH/PEDESTAL TABLE. (EXCAVATION: 3' SQ.) AT SYMBOL: INSTALL JUNCTION BOX HANDHOLE. ADDITIONAL EQUIPMENT AS INDICATED ON VAULT TABLE. AT SYMBOL: INSTALL SECONDARY CABLE & CONDUIT STUB-OUT. AT SYMBOL: INSTALL STREET LIGHTING STANDARD. SIZE AND TYPE OF STANDARD/LUMINARIE AS INDICATED ON STREET LIGHTING TABLE. (CUSTOMER TO EXCAVATE & INSTALL CORRUGATED STREET LIGHT TUBES FOR PLACEMENT OF THE STREET LIGHT STANDARDS. ) INCLEMENT WEATHER CONDITIONS MAY CAUSE DELAYS IN CONSTRUCTION TIMES AND DATES. POWER GENERAL NOTES - PLAT PROJECT 105098738107061200Phone INTOLIGHT Contact Information: LARS LARSON 425.456.2701 DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP D. BETTENCOURT 206.445.5958 . A. VASQUEZ .04.13.22 ... A. VASQUEZ .04.13.22 REDT # ( RW-124573 )YELM MOUNTAIN MEADOWS 1Ø PRIMARY U/G LINE EXTENSION - 22 S/F LOTS P# 21713310400, 8818 BURNETT RD SE, YELM, WA, 98597 PUGET SOUND ENERGY N/A IP 344-60 107061200 105098738 N/A 1 OF 4 THURSTON 344 CIONC QSTHLE 13SW-T17N-R01E 281.042 280.038 1701E051 1702E068 1701E051 YEL-25 COMCAST TED AXTELL 253.878.2794 LUMEN . . RIGHT OF WAY CAROLYN BANASKY 253.476.6416 . . . 11. E-Mail: Cell Phone: Project Manager Contact Information: Manager:DON BETTENCOURT 206.445.5958 Don.Bettencourt@pse.com x xx Standoff Bracket 15" Min Length Conduit Clamp Conduit Field Face Quadrant Climbing Space Road Face Quadrant Climbing Space 5" Min CL LCDirection of Vehicular Traffic CONDUIT RISER PLACEMENT DETAIL TOP VIEW NOT TO SCALE ... ... ... EVAN@SOUNDBUILTHOMES.COM VAULT DETAIL @ V01-V03 NOT TO SCALE TOP VIEW SIDE VIEW EXCAVATION: 4-2/3 CUBIC YARDS Rock Crushed 6" 3'-6" 2" 6' 6' 48"42" 36" 38" 42" Struts FRONT FRONTTYPICAL NOTCH-OUT FOR TRANSFORMER, NOT TO SCALE & SECONDARY PEDESTAL/HANDHOLE BACK OF EASEMENT STANDARD EASEMENT LINE ROW 10' PL 1' 4' - 5' Min. 1' 7'7' TRANSFORMER (WHEN PRESENT) 42" 45°42" 1' 45°Property LineRoad Side Top View of Mainline Trench for Single Stubout Location 4'Property LineRoad Side Top View of Mainline Trench for Pedestal or Double Stubout Location 42"45° 4' 45° STUBOUT EXCAVATION DIMENSIONS NOT TO SCALE JOINT TRENCH DETAIL NOT TO SCALE JOINT TRENCH DETAIL NOTES: 1. If the final backfill contains rocks greater than 8 inches in diameter , install 12 inches compacted sand shading across the full width of the trench. * If the final backfill contains rocks 8 inches in diameter or smaller , install 6 inches compacted sand shading across the full width of the trench. * 2. Rocks greater than 10 inches diameter are not permitted in the final backfill. 3. Sand bedding is required under PSE gas pipe. Bedding is not required for the full width of the trench; it shall extend from the side of the trench nearest to where the gas main/service is installed to a minimum of 6 inches on the opposite side of the gas line. 4. Utilities shall not be stacked over the gas line in the trench. 5. If wet utilities will be included in the trench, please contact PSE or local power company directly for clearance requirements. 6. Reduced clearance of 4 inches between power and communication, must have approval of the communications companies. * Alternatives to full-width trench shading require PSE approval. Primary & Secondary-Mainline Gas & Communications (NTS) ROAD SIDE NATIVE SECONDARY POWER PEDESTAL MATERIAL P/L Power Secondary Power Primary Conduit Tel. & TV 12" Min 12" Sand Cover when gas line is in trench Sand 6" or 12" 4" Sand Bedding 1' 36" Cover 42" Gas 12" 18" Lower 2" 10" Pedestal PSE 10' FRONTAGE EASEMENT 1' Cover ROAD SIDE MINIPAD MINIPAD FIELD SIDE VAULT 6" of crushed rock (base for vault) P/L Power Secondary Power Primary Gas 12" Min Horizontal Separation Communications 42" Min 21"1' Feeder 38" 2" 4" Sand Bedding 12" Sand Cover 36" Cover 4" Sand Bedding 42" 6" Additional depth when Feeder is required PSE 10' FRONTAGE EASEMENT 1' TRANSFORMER Final Backfill Initial Backfill Trench Depth 42" - 48" Primary Dirt Pile Final Grade 24" Min 36" Min Cover Over Power 48" Max Depth Final Backfill Gas 4" Sand Bedding Property Line intercept (depth varies). SidewalkCurb Location of roof drain 48" Typical Width may vary per Number of Utilities and Conduits 6" or 12" Min Sand Shading Over Gas after Compaction 12" Min R/W or Excavated 12" Typical Power Secondary Power TV & TEL 12" Min 12" Min Separation 4,5 1,2 1 3 6 6" or 12" Min Sand Shading Over Power after Compaction1 MINIMUM CLEARANCES FOR PSE EQUIPMENT NOT TO SCALE OIL-FILLED EQUIPMENT TRANSFORMER APPROVED AREA COMBUSTIBLE BUILDING WALLS & ROOF10' 10' 10' COOLING 5' MIN 5' MIN 10' MIN 5' MIN FINS ACCESS CONCRETE PAD MINIMUM CLEARANCES FOR PSE EQUIPMENT NOT TO SCALE CURB OR EDGE OF PAVEMENT CURB OR EDGE OF PAVEMENT 5' MIN ROAD OR PARKING AREA TYP. PAD & TRANS- FORMER 3' MIN 3' MIN DOOR ACCESS DOOR REQUIRED WORK SPACE AREA 3' MIN @ H1A SHALL BE STAGGERED CONNECTOR BARS IN THE FRONT NEUTRALS SHALL BE 18" 16" 13" 12"10" 2" 10" Pedestal will accept up to six 3" conduits SEALED WITH FOAM CONDUIT SHALL BE 120 PVC CONDUIT ELBOWS TYPICAL 24" RADIUS DB SIDE VIEW WITH CONDUIT 10" 18" 16" 13" 10" 2" 36" FRONT VIEW WITH CONDUIT SECONDARY PEDESTAL DETAIL NOT TO SCALE J-BOX CABLE ENTRY DETAIL NOT TO SCALE 12kV CABLE ROUTING Cables should enter the vault so that all of the cables will lay in the same direction. TOP VIEW SITE 1 2 3 4 5 14 13 12 11 109 TRACT A OPEN SPACE 17 16 15 19 18 76 8 202122 56' 14740 14867 14872GAS ONLY89TH WAY SE89TH AVE SEBURNETT RD SE89TH WAY SE #4ACSR14822 14834 8812 14770 8815FEED EX 1-2"BURNETT RD SE50' 'A' 'B' 8815 C FUSE @ 40T SW#T87221 56'56'40' YEL 25 A C A C A FEED YEL 25 SW#T87222 # 4 C U # 4 C U ABCABCC #4ACSRA Y E L M HW Y S E BURNETT RD SE50'60'1" = 50' DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP D. BETTENCOURT 206.445.5958 . A. VASQUEZ .04.13.22 ... A. VASQUEZ .04.13.22 REDT # ( RW-124573 )YELM MOUNTAIN MEADOWS 1Ø PRIMARY U/G LINE EXTENSION - 22 S/F LOTS P# 21713310400, 8818 BURNETT RD SE, YELM, WA, 98597 PUGET SOUND ENERGY N/A IP 344-60 107061200 105098738 1" = 50'2 OF 4 THURSTON 344 CIONC QSTHLE 13SW-T17N-R01E 281.042 280.038 1701E051 1702E068 1701E051 YEL-25 COMCAST TED AXTELL 253.878.2794 LUMEN . . RIGHT OF WAY CAROLYN BANASKY 253.476.6416 . . . SITE PLAN CIRCUIT LOADING TABLE AS OF EXIST. PEAK LOAD EST. NEW LOAD TOTAL CIRCUIT: A PHASE B PHASE C PHASE YEL-25 12.02.21 287 340 326 19 N/A N/A 306 340 326 ... ... ... SCHED.SQ. FT. MAX LRC = CIRCUIT FEET ADDED: 1170' 17 3500 115 AMPS THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) DEDICATED FACILITIES (105098738) Dedicated Stub Locations SITE SPAN ADDITIONAL REMARKS LABOR UNITS #FROM TO FOOTAGE -V02 LOT 6 35 DED. CONDUIT & WIRE 2-36, 2-54A -V02 LOT 7 30 DED. CONDUIT & WIRE 2-36, 2-54A -V02 LOT 9 20 DED. CONDUIT & WIRE 2-36, 2-54A -V03 LOT 10 20 DED. CONDUIT & WIRE 2-36, 2-54A -V03 LOT 12 40 DED. CONDUIT & WIRE 2-36, 2-54A -V03 LOT 13 45 DED. CONDUIT & WIRE 2-36, 2-54A -V02 LOT 17 65 DED. CONDUIT & WIRE 2-36, 2-54A -H1A LOT 18 55 DED. CONDUIT & WIRE 2-36, 2-54A -V01 LOT 20 45 DED. CONDUIT & WIRE 2-36, 2-54A -V01 LOT 21 45 DED. CONDUIT & WIRE 2-36, 2-54A TOTAL FT=400 SITE SPECIFIC NOTES DEVELOPER TO COORDINATE WITH PSE PROJECT MANGER & SERVICE PROVIDER PRIOR TO EXCAVATING WITHIN 3' OF LOCATE MARKS OF PSE ENERGIZED FACILITIES CROSSING CONDUIT TABLE X-ING # LOCATION GAS POWER XING LENGTH ASBUILT LOCATION TYPE OF CROSSING (Feeder, Primary, Secondary, etc.)FROM TO SIZE (IN)TYPE QTY LOCATION SIZE (IN)TYPE QTY X01 'A'TR. A ELEC ONLY 2 DB120 1 105 ( )' SCL PRIMARY X02 TR. A 'B'4 40 1 W GAS ONLY 65 ( )' ECL GAS MAIN X03 LOT 21 LOT 1 2 40 1 E 3 DB120 2 65 ( )' ECL GAS SVC, SECONDARY X04 LOT 18 LOT 4 2 40 1 W 3 DB120 2 65 ( )' WCL GAS SVC, SECONDARY X05 LOT 18 LOT 5 4 40 1 E 2 DB120 1 65 ( )' WCL GAS MAIN, PRIMARY ----3 DB120 1 65 ( )' WCL SECONDARY X06 LOT 14 LOT 15 2 40 1 N 3 DB120 2 65 ( )' SCL GAS SVC, SECONDARY 2" PVC PLUG /CAPS = 6 2" YELLOW SCH 40 PVC = 195 FT 2" DB120 GREY PVC = 170 FT 2" PVC PLUG /CAPS = 4 4" PVC PLUG /CAPS = 4 4" YELLOW SCH 40 PVC = 130 FT 3" DB120 GREY PVC = 455 FT 3" PVC PLUG /CAPS = 14 BREAKLINE~1540' AT P01 (559804-146888) 40' CLASS 3, 1978 -TRANSFER EXISTING 'C' PHASE TAP TO 'A' PHASE AT P02 (559810-146896) 40' CLASS 3, 1978 -INSTALL SWITCH # T87222 AT P03 (560022-146902) 40' CLASS 3, 1971 -INSTALL 1Ø TERM ON NEW BI-UNIT (8721000) FIBERGLASS ARM W/ LINK BREAK C/O & SURGE ARRESTOR (TSU1C1) 6043.1000 -STIRRUP (2254000) -ALUM "H" CONNECTOR (2167000) -FUSE @ 40T (3412500); TAP 'A' PHASE -INSTALL SWITCH # T87221 -INSTALL 2" PRI RISER ON EXISTING STANDOFF BRACKETS(RIS2CSS) 6042.1000 NEW 1/O AL EJG776-AØ BØADK911#4ACSRBØADK910FEED'A' FUSE @ 40T SW#T87221 YEL 25 C A C A C A FEED YEL 25 NEW 1/O AL EJG777-AØ NEW 1/O AL EJG779-AØ BØADK966 BØADL027 BØADL112 NEW 1/O AL EJG778-AØ BØADL028 BØADL029 DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP D. BETTENCOURT 206.445.5958 . A. VASQUEZ .04.13.22 ... A. VASQUEZ .04.13.22 REDT # ( RW-124573 )YELM MOUNTAIN MEADOWS 1Ø PRIMARY U/G LINE EXTENSION - 22 S/F LOTS P# 21713310400, 8818 BURNETT RD SE, YELM, WA, 98597 PUGET SOUND ENERGY N/A IP 344-60 107061200 105098738 AS SHOWN 3 OF 4 THURSTON 344 CIONC QSTHLE 13SW-T17N-R01E 281.042 280.038 1701E051 1702E068 1701E051 YEL-25 COMCAST TED AXTELL 253.878.2794 LUMEN . . RIGHT OF WAY CAROLYN BANASKY 253.476.6416 . . . ... ... ... EX OVERHEAD CIRCUIT MAP 1702E068 SCALE: 6" = 1 MILE NEW PRIMARY UNDERGROUND CIRCUIT ONE-LINE DIAGRAM NOT TO SCALE EX UNDERGROUND CIRCUIT MAP 1701E051 NOT TO SCALE SITE THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) PRIMARY CABLE & CONDUIT TABLE LOCATION CONDUIT CABLE ASBUILT INFORMATION - FOREMAN COMPLETE FROM TO SIZE (IN)QTY. DESIGN LENGTH (FT) BENDS PULL (LBS) PULL REV (LBS) CABLE SIZE DESIGN LENGTH (FT) PHASE - ID TAG RECORD RECORD PHASE TAPPED & ACTUAL FOOTAGE INSTALLED LUBRICANT (Gal.) 90°45°22°11°A B C MANUFACTURER COMPOUND YEAR NOTES CONDUIT CABLE EST.ACTUAL P03 V01 2 1 275 1 ---99 204 1/0 AL JKT 420 EJG776 ---1.7 V01 V02 2 1 230 2 ---216 202 1/0 AL JKT 305 EJG777 ---1.2 V02 V03 2 1 165 --2 -109 108 1/0 AL JKT 175 EJG778 ---0.7 V03 E01 2 1 110 ----CONDUIT ONLY ----- V03 V04 CABLE ONLY 122 133 1/0 AL JKT 340 EJG779 ---1.4 2" PVC (FT) & BENDS =780 3 0 2 0 1/0 AL JKT TOTAL (FT) =1240 TTL(Gal.) = 5.0 VAULT & EQUIPMENT TABLE SITE #GRID # VAULT SIZE & COVER TYPE & SIZE EQUIPMENT IN VAULT PRIMARY BUSHINGS TRANSFORMER ID NUMBERS (COMPANY ID) AS-BUILT INFORMATION LB DC FOREMAN: INCLUDE PHASE TAPPED V01 560008 146935 42"x48"x38" Unistrut HH Matid: 7663001 50KVA MP TRF 120/240 Matid: 6247100 2 - MINU1SL 6045.1010 AØ V02 560023 146957 42"x48"x38" Unistrut HH Matid: 7663001 50KVA MP TRF 120/240 Matid: 6247100 2 - MINU1SL 6045.1010 AØ V03 560011 146968 42"x48"x38" Unistrut HH Matid: 7663001 50KVA MP TRF 120/240 Matid: 6247100 2 - MINU1SL 6045.1010 AØ Existing V04 559977 146963 4'x6'x3'6" Combo Vault Matid: Existing 37.5KVA MP TRF 120/240 Matid: Existing 1 - ELB10J 6041.1000 EX BØ SITE 'A' 1 2 3 4 5 14 13 12 11 10 9 17 16 15 19 18 7 6 8 20 2122 DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP D. BETTENCOURT 206.445.5958 . A. VASQUEZ .04.13.22 ... A. VASQUEZ .04.13.22 REDT # ( RW-124573 )YELM MOUNTAIN MEADOWS 1Ø PRIMARY U/G LINE EXTENSION - 22 S/F LOTS P# 21713310400, 8818 BURNETT RD SE, YELM, WA, 98597 PUGET SOUND ENERGY N/A IP 344-60 107061200 105098738 N/A 4 OF 4 THURSTON 344 CIONC QSTHLE 13SW-T17N-R01E 281.042 280.038 1701E051 1702E068 1701E051 YEL-25 COMCAST TED AXTELL 253.878.2794 LUMEN . . RIGHT OF WAY CAROLYN BANASKY 253.476.6416 . . . ... ... ... NOT TO SCALE NEW CONDUIT DIAGRAM 1. 2. 3. 4. 5. ALL STREET LIGHTING POLES ARE TO BE INSTALLED PER STANDARD 6375.4800 (page #2) IN THE "LINE WORK PRACTICES MANUAL". ALL POLES (WOOD, CONCRETE OR FIBERGLASS) ARE TO BE SET PLUMB AND EMBEDDED TO THE GROUND LINE MARKED ON THE POLE. BACKFILL AROUND POLE WITH 5/8" MINUS GRAVEL AND COMPACT IN 6" LIFTS. (PEA GRAVEL AND NATIVE SOILS ARE NOT ACCEPTABLE.) APPROXIMATELY 1 CU. YD. OF 5/8" MINUS CRUSHED ROCK WILL BE REQUIRED. THE DEVELOPER IS REQUIRED TO SUPPLY AND INSTALL PLASTIC (NON PAPER) STREET LIGHT TUBES (MINIMUM 18" DIAMETER) TO AID IN THE INSTALLATION OF THE STREET LIGHTING POLES. THE DEVELOPER MUST ALSO SUPPLY THE REQUIRED 5/8" MINUS GRAVEL AT EACH STREET LIGHT LOCATION. IN ALL SHOEBOX AND COBRAHEAD INSTALLATIONS, THE LUMINAIRE MUST BE LEVELED. DEVELOPER MUST SUPPLY DURABLE LID/COVER AT EACH STREET LIGHT TUBE. 6. NOT TO SCALE STREET LIGHT TUBE DETAIL Plan View Detail of Street Light Tube Wire Entrance Slot Street Light Tube Field Side Road Side Wire Entrance Slot 45° 45° Position 3" x 6" wire entrance slot 45 degrees left or right from a line perpendicular to road- way through center of tube. Field Side 3" x 6" Wire Entrance Slot 45° 45° Street light tube set 2" below grade. Road Side 18" - 24" Minimum Depending on Pole Type 5'-0" 20" 26" SECONDARY HH/PEDESTAL TABLE Site Pedestal or Handhole Number of Positions Required Remarks H1A PEDESTAL 4 - SEPS4 6050.1000 SECONDARY CABLE & CONDUIT TABLE LOCATION CABLE CONDUIT VOLTAGE ASBUILT INFORMATION SIZE LENGTH ASSUMED SIZE LENGTH BENDS DROP FLICKER Foreman - Complete FROM TO (1/O,4/O,350)Design (ft)Lot Corner to Meter (ft)(in)Design (ft)90°45°22°11°(Percent)(Percent)Actual Amount Installed Cable Conduit V01 H1A 350 115 3 115 2 3.3 2.0 V01 LOT 1 4/O 95 70 3 30 2 4.0 3.4 V01 LOT 2 4/O 95 70 3 30 3 4.0 3.4 V01 LOT 19 1/O 60 70 3 60 1 4.2 3.6 V01 LOT 20 1/O 55 70 3 55 1 4.1 3.5 V01 LOT 21 1/O 55 70 3 55 1 4.1 3.5 V01 LOT 22 1/O 60 70 3 60 1 4.2 3.6 H1A LOT 3 4/O 85 70 3 20 3 4.4 3.5 LABEL YELLOW TAG "MUST BE 4/0 TO MTR" H1A LOT 4 4/O 85 70 3 20 2 4.4 3.5 LABEL YELLOW TAG "MUST BE 4/0 TO MTR" H1A LOT 18 4/O 55 70 3 55 1 4.7 3.8 V02 LOT 5 1/O 50 70 3 50 1 3.5 3.4 V02 LOT 6 1/O 45 70 3 45 1 3.4 3.3 V02 LOT 7 1/O 40 70 3 40 1 3.4 3.2 V02 LOT 8 1/O 45 90 3 45 1 3.7 3.7 V02 LOT 9 4/O 85 120 3 85 1 3.3 3.2 LABEL YELLOW TAG "MUST BE 4/0 TO MTR" V02 LOT 17 4/O 165 70 3 100 3 3.5 3.5 LABEL YELLOW TAG "MUST BE 4/0 TO MTR" V03 LOT 10 4/O 95 160 3 95 1 3.8 3.7 LABEL YELLOW TAG "MUST BE 4/0 TO MTR" V03 LOT 11 1/O 55 70 3 55 1 3.8 3.5 V03 LOT 12 1/O 50 70 3 50 1 3.7 3.4 V03 LOT 13 1/O 55 70 3 55 1 3.8 3.5 V03 LOT 14 1/O 60 70 3 60 1 3.8 3.6 V03 LOT 15 4/O 130 70 3 65 2 3.9 3.8 V03 LOT 16 4/O 130 70 3 65 3 3.9 3.8 1/O UG Triplex (ft) =630 3" PVC & BENDS (ft)=1310 35 0 0 0 3.9 4/O UG Triplex (ft) =1020 350 UG Triplex (ft) =115 TOTAL QTS OF GLUE 3.9 STREET LIGHT CIRCUITRY TABLE - 105099610 SITE #FROM CABLE INFO AS-BUILT REMARKSTYPELFTYPELENGTH FL1 -#6 CIC -- BY INTOLIGHT FL2 -#6 CIC -- BY INTOLIGHT FL3 -#6 CIC -- BY INTOLIGHT FL4 -#6 CIC -- BY INTOLIGHT SL1 -#6 CIC - SL2 -#6 CIC - SL3 -#6 CIC - SL4 -#6 CIC - SL5 -#6 CIC - SL6 -#6 CIC - TOTAL FT =###TOTAL FT = STREET LIGHT TABLE (BY INTOLIGHT) SITE # STATION OFFSET POLE LUMINAIRE TUBE WO # (INTOLIGHT) BILLING SCH.GRID #INTOLIGHT TAG #TYPE ARM MTG HT.WATTS STYLE TUBE LENGTH TUBE DIAMETER SL1 -XXXXX XXXXX ---------- SL2 -XXXXX XXXXX ---------- SL3 -XXXXX XXXXX ---------- SL4 -XXXXX XXXXX ---------- SL5 -XXXXX XXXXX ---------- SL6 -XXXXX XXXXX ---------- SL7 -XXXXX XXXXX ---------- SL8 -XXXXX XXXXX ---------- SL9 -XXXXX XXXXX ---------- SL10 -XXXXX XXXXX ---------- THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) SECONDARY 3" PRIMARY 2" CONDUIT LEGEND ST. LIGHTS