Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2155 A ROOF SEALS
Tri-State Engineering, Inc. 12810 NE 178th Street Suite 218 Woodinville, WA 98072 425.481.6601 J1070180 The Truss Company (Sumner). August 20, 2022.My license renewal date for the state of Washington is Pages or sheets covered by this seal: MFour Contractors, LLC Terry Powell March 5,2021 The truss drawing(s) referenced below have been prepared by Tri-State Engineering under my direct supervision based on the parameters provided by The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer, per ANSI/TPI 1. Re: thru I13684900I13684880 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719.Safety Information Job J1070180 Truss A1 Truss Type GABLE Qty 1 Ply 1 MFour Contractors, LLC Job Reference (optional) I13684880 8.430 s Nov 30 2020 MiTek Industries, Inc. Fri Mar 5 13:11:33 2021 Page 1 The Truss Company (Sumner), Sumner, WA - 98390, ID:bVkDiYavCeF3Q1Shm7wAy6ycOfW-JrRd5s8_st_ELClUnZKcRYaLnbrnuZitU4uT0SzdywO Scale = 1:49.1 1 2 3 4 5 6 7 8 9 12 11 1047483x10 4x4 3x4 4x4 4x10 4x4 4x4 4x4 4x8 4x4 4x4 3x10 3x6 3x6 3x6 3x6 3x6 3x6 8x8 5x6 8x8 9-0-10 9-0-10 17-5-6 8-4-13 26-6-0 9-0-10 -1-0-0 1-0-0 6-11-6 6-11-6 13-3-0 6-3-10 19-6-10 6-3-10 26-6-0 6-11-6 27-6-0 1-0-0 0-4-15-10-50-4-15.00 12 Plate Offsets (X,Y)-- [2:0-3-4,0-1-8], [3:0-4-4,0-2-0], [4:0-1-0,0-1-8], [5:0-1-12,0-2-0], [5:0-2-0,0-0-9], [6:0-1-0,0-1-8], [7:0-3-4,0-0-8], [8:0-3-4,0-1-8], [11:0-3-0,0-3-0], [30:3-1-0 ,0-2-0], [46:3-1-0,0-2-0] LOADING (psf) TCLL (Roof Snow=25.0) TCDL BCLL BCDL 25.0 8.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.18 0.79 0.34 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.21 -0.31 0.08 (loc) 10-12 10-12 8 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 181 lb FT = 20% GRIP 185/148 LUMBER- TOP CHORD 2x4 DF No.1&Btr BOT CHORD 2x4 HF No.2 WEBS 2x4 HF Stud OTHERS 2x4 HF Stud SLIDER Left 2x4 DF No.1&Btr - 6-9-1, Right 2x4 DF No.1&Btr -t 6-9-1 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-11-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-5-8, 8=0-5-8 Max Horz 2=-67(LC 11) Max Uplift 2=-80(LC 10), 8=-80(LC 11) Max Grav 2=1180(LC 3), 8=1180(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2299/137, 3-5=-2052/127, 5-7=-2052/127, 7-8=-2299/138 BOT CHORD 2-12=-139/2092, 10-12=-14/1286, 8-10=-72/2092 WEBS 3-12=-643/148, 5-12=-60/893, 5-10=-61/893, 7-10=-643/149 NOTES-(12) 1) Wind: ASCE 7-16; Vult=110mph (3-second gust) Vasd=87mph; TCDL=4.8psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pf=25.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 23.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 7.0psf. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 80 lb uplift at joint 2 and 80 lb uplift at joint 8. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) All dimensions given in feet-inches-sixteenths (FFIISS) format. March 5,2021 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719.Safety Information Job J1070180 Truss A2 Truss Type Common Qty 7 Ply 1 MFour Contractors, LLC Job Reference (optional) I13684881 8.430 s Nov 30 2020 MiTek Industries, Inc. Fri Mar 5 13:11:34 2021 Page 1 The Truss Company (Sumner), Sumner, WA - 98390, ID:bVkDiYavCeF3Q1Shm7wAy6ycOfW-n1??IC9cdB65zMKgLGrrzm7LC?APd1P1ike0YuzdywN Scale = 1:45.7 1 2 3 4 5 6 7 10 9 81112 5x6 3x6 3x6 3x4 1.5x4 3x4 1.5x4 3x6 9-0-10 9-0-10 17-5-6 8-4-13 26-6-0 9-0-10 -1-0-0 1-0-0 6-11-6 6-11-6 13-3-0 6-3-10 19-6-10 6-3-10 26-6-0 6-11-6 27-6-0 1-0-0 0-4-15-10-50-4-15.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-8], [6:0-3-0,0-1-8], [8:0-1-8,0-1-8], [10:0-1-8,0-1-8] LOADING (psf) TCLL (Roof Snow=25.0) TCDL BCLL BCDL 25.0 8.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.84 0.83 0.31 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.23 -0.37 0.08 (loc) 8-10 6-8 6 l/defl >999 >843 n/a L/d 360 240 n/a PLATES MT20 Weight: 91 lb FT = 20% GRIP 185/148 LUMBER- TOP CHORD 2x4 HF No.2 BOT CHORD 2x4 HF No.2 WEBS 2x4 HF Stud BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-7-8, 6=0-5-8 Max Horz 2=67(LC 14) Max Uplift 2=-81(LC 10), 6=-80(LC 11) Max Grav 2=1184(LC 3), 6=1180(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2210/134, 3-4=-1977/124, 4-5=-1990/125, 5-6=-2228/136 BOT CHORD 2-10=-133/1987, 8-10=-17/1291, 6-8=-67/2007 WEBS 4-8=-53/817, 5-8=-561/142, 4-10=-52/800, 3-10=-547/140 NOTES-(9) 1) Wind: ASCE 7-16; Vult=110mph (3-second gust) Vasd=87mph; TCDL=4.8psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=25.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 23.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 7.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 81 lb uplift at joint 2 and 80 lb uplift at joint 6. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) All dimensions given in feet-inches-sixteenths (FFIISS) format. March 5,2021 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719.Safety Information Job J1070180 Truss A2SL Truss Type Common Qty 1 Ply 1 MFour Contractors, LLC Job Reference (optional) I13684882 8.430 s Nov 30 2020 MiTek Industries, Inc. Fri Mar 5 13:11:35 2021 Page 1 The Truss Company (Sumner), Sumner, WA - 98390, ID:bVkDiYavCeF3Q1Shm7wAy6ycOfW-FEZOWXAFOVEybWvtv_M4WzfWyOVeMUfAxONa5LzdywM Scale = 1:45.7 1 2 3 4 5 6 7 10 9 81112 5x6 3x6 3x6 3x4 1.5x4 3x4 1.5x4 3x6 9-0-10 9-0-10 17-5-6 8-4-13 26-6-0 9-0-10 -1-0-0 1-0-0 6-11-6 6-11-6 13-3-0 6-3-10 19-6-10 6-3-10 26-6-0 6-11-6 27-6-0 1-0-0 0-4-15-10-50-4-15.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-8], [6:0-3-0,0-1-8], [8:0-1-8,0-1-8], [10:0-1-8,0-1-8] LOADING (psf) TCLL (Roof Snow=25.0) TCDL BCLL BCDL 25.0 8.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.84 0.83 0.31 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.23 -0.37 0.08 (loc) 8-10 6-8 6 l/defl >999 >843 n/a L/d 360 240 n/a PLATES MT20 Weight: 91 lb FT = 20% GRIP 185/148 LUMBER- TOP CHORD 2x4 HF No.2 BOT CHORD 2x4 HF No.2 WEBS 2x4 HF Stud BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-7-8, 6=0-5-8 Max Horz 2=67(LC 14) Max Uplift 2=-81(LC 10), 6=-80(LC 11) Max Grav 2=1184(LC 3), 6=1180(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2210/134, 3-4=-1977/124, 4-5=-1990/125, 5-6=-2228/136 BOT CHORD 2-10=-133/1987, 8-10=-17/1291, 6-8=-67/2007 WEBS 4-8=-53/817, 5-8=-561/142, 4-10=-52/800, 3-10=-547/140 NOTES-(9) 1) Wind: ASCE 7-16; Vult=110mph (3-second gust) Vasd=87mph; TCDL=4.8psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=25.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 23.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 7.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 81 lb uplift at joint 2 and 80 lb uplift at joint 6. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) All dimensions given in feet-inches-sixteenths (FFIISS) format. March 5,2021 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719.Safety Information Job J1070180 Truss A2SR Truss Type Common Qty 1 Ply 1 MFour Contractors, LLC Job Reference (optional) I13684883 8.430 s Nov 30 2020 MiTek Industries, Inc. Fri Mar 5 13:11:35 2021 Page 1 The Truss Company (Sumner), Sumner, WA - 98390, ID:bVkDiYavCeF3Q1Shm7wAy6ycOfW-FEZOWXAFOVEybWvtv_M4WzfWyOVeMUfAxONa5LzdywM Scale = 1:45.7 1 2 3 4 5 6 7 10 9 81112 5x6 3x6 3x6 3x4 1.5x4 3x4 1.5x4 3x6 9-0-10 9-0-10 17-5-6 8-4-13 26-6-0 9-0-10 -1-0-0 1-0-0 6-11-6 6-11-6 13-3-0 6-3-10 19-6-10 6-3-10 26-6-0 6-11-6 27-6-0 1-0-0 0-4-15-10-50-4-15.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-8], [6:0-3-0,0-1-8], [8:0-1-8,0-1-8], [10:0-1-8,0-1-8] LOADING (psf) TCLL (Roof Snow=25.0) TCDL BCLL BCDL 25.0 8.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.84 0.83 0.31 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.23 -0.37 0.08 (loc) 8-10 6-8 6 l/defl >999 >843 n/a L/d 360 240 n/a PLATES MT20 Weight: 91 lb FT = 20% GRIP 185/148 LUMBER- TOP CHORD 2x4 HF No.2 BOT CHORD 2x4 HF No.2 WEBS 2x4 HF Stud BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-7-8, 6=0-5-8 Max Horz 2=67(LC 14) Max Uplift 2=-81(LC 10), 6=-80(LC 11) Max Grav 2=1184(LC 3), 6=1180(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2210/134, 3-4=-1977/124, 4-5=-1990/125, 5-6=-2228/136 BOT CHORD 2-10=-133/1987, 8-10=-17/1291, 6-8=-67/2007 WEBS 4-8=-53/817, 5-8=-561/142, 4-10=-52/800, 3-10=-547/140 NOTES-(9) 1) Wind: ASCE 7-16; Vult=110mph (3-second gust) Vasd=87mph; TCDL=4.8psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=25.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 23.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 7.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 81 lb uplift at joint 2 and 80 lb uplift at joint 6. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) All dimensions given in feet-inches-sixteenths (FFIISS) format. March 5,2021 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719.Safety Information Job J1070180 Truss A3 Truss Type COMMON Qty 9 Ply 1 MFour Contractors, LLC Job Reference (optional) I13684884 8.430 s Nov 30 2020 MiTek Industries, Inc. Fri Mar 5 13:11:36 2021 Page 1 The Truss Company (Sumner), Sumner, WA - 98390, ID:bVkDiYavCeF3Q1Shm7wAy6ycOfW-jQ7mjtAt9oMpCgU3ThtJ3BChoort5xvKA277dnzdywL Scale = 1:44.6 1 2 3 4 5 6 9 8 71011 4x4 4x6 3x6 3x4 1.5x4 3x4 1.5x4 3x6 8-9-10 8-9-10 17-2-6 8-4-13 26-3-0 9-0-10 6-8-6 6-8-6 13-0-0 6-3-10 19-3-10 6-3-10 26-3-0 6-11-6 27-3-0 1-0-0 0-5-55-10-50-4-15.00 12 Plate Offsets (X,Y)-- [1:0-1-1,0-1-15], [5:0-3-0,0-1-8], [7:0-1-8,0-1-8], [9:0-1-8,0-1-8] LOADING (psf) TCLL (Roof Snow=25.0) TCDL BCLL BCDL 25.0 8.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.84 0.83 0.31 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.23 -0.37 0.08 (loc) 7-9 5-7 5 l/defl >999 >841 n/a L/d 360 240 n/a PLATES MT20 Weight: 89 lb FT = 20% GRIP 185/148 LUMBER- TOP CHORD 2x4 HF No.2 BOT CHORD 2x4 HF No.2 WEBS 2x4 HF Stud BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=0-2-8, 5=0-5-8 Max Horz 1=-72(LC 15) Max Uplift 1=-63(LC 10), 5=-80(LC 11) Max Grav 1=1111(LC 3), 5=1179(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2212/137, 2-3=-1979/126, 3-4=-1989/125, 4-5=-2226/136 BOT CHORD 1-9=-136/1988, 7-9=-18/1291, 5-7=-68/2006 WEBS 3-7=-53/817, 4-7=-561/142, 3-9=-54/803, 2-9=-548/141 NOTES-(10) 1) Wind: ASCE 7-16; Vult=110mph (3-second gust) Vasd=87mph; TCDL=4.8psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=25.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 23.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 7.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 1. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 63 lb uplift at joint 1 and 80 lb uplift at joint 5. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) All dimensions given in feet-inches-sixteenths (FFIISS) format. March 5,2021 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719.Safety Information Job J1070180 Truss A3SR Truss Type COMMON Qty 1 Ply 1 MFour Contractors, LLC Job Reference (optional) I13684885 8.430 s Nov 30 2020 MiTek Industries, Inc. Fri Mar 5 13:11:37 2021 Page 1 The Truss Company (Sumner), Sumner, WA - 98390, ID:bVkDiYavCeF3Q1Shm7wAy6ycOfW-Bch8xDBVv6Ugqq3F0OOYbOlsYCB6qO9TOisg9DzdywK Scale = 1:44.6 1 2 3 4 5 6 9 8 71011 4x4 4x6 3x6 3x4 1.5x4 3x4 1.5x4 3x6 8-9-10 8-9-10 17-2-6 8-4-13 26-3-0 9-0-10 6-8-6 6-8-6 13-0-0 6-3-10 19-3-10 6-3-10 26-3-0 6-11-6 27-3-0 1-0-0 0-5-55-10-50-4-15.00 12 Plate Offsets (X,Y)-- [1:0-1-1,0-1-15], [5:0-3-0,0-1-8], [7:0-1-8,0-1-8], [9:0-1-8,0-1-8] LOADING (psf) TCLL (Roof Snow=25.0) TCDL BCLL BCDL 25.0 8.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.84 0.83 0.31 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.23 -0.37 0.08 (loc) 7-9 5-7 5 l/defl >999 >841 n/a L/d 360 240 n/a PLATES MT20 Weight: 89 lb FT = 20% GRIP 185/148 LUMBER- TOP CHORD 2x4 HF No.2 BOT CHORD 2x4 HF No.2 WEBS 2x4 HF Stud BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=0-2-8, 5=0-5-8 Max Horz 1=-72(LC 15) Max Uplift 1=-63(LC 10), 5=-80(LC 11) Max Grav 1=1111(LC 3), 5=1179(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2212/137, 2-3=-1979/126, 3-4=-1989/125, 4-5=-2226/136 BOT CHORD 1-9=-136/1988, 7-9=-18/1291, 5-7=-68/2006 WEBS 3-7=-53/817, 4-7=-561/142, 3-9=-54/803, 2-9=-548/141 NOTES-(10) 1) Wind: ASCE 7-16; Vult=110mph (3-second gust) Vasd=87mph; TCDL=4.8psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=25.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 23.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 7.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 1. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 63 lb uplift at joint 1 and 80 lb uplift at joint 5. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) All dimensions given in feet-inches-sixteenths (FFIISS) format. March 5,2021 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719.Safety Information Job J1070180 Truss A4 Truss Type GABLE Qty 1 Ply 1 MFour Contractors, LLC Job Reference (optional) I13684886 8.430 s Nov 30 2020 MiTek Industries, Inc. Fri Mar 5 13:11:39 2021 Page 1 The Truss Company (Sumner), Sumner, WA - 98390, ID:bVkDiYavCeF3Q1Shm7wAy6ycOfW-8?puMvDlRjkO37Ce8pR0gpqNH0uIIHCms0LnE6zdywI Scale = 1:45.1 1 2 3 4 5 6 7 8 11 10 9474x6 3x6 4x4 3x4 3x4 4x10 4x4 4x4 4x4 4x10 4x4 4x4 3x10 3x6 3x6 3x6 3x6 3x6 3x6 8x8 8x8 8-9-10 8-9-10 17-2-6 8-4-13 26-3-0 9-0-10 6-8-6 6-8-6 13-0-0 6-3-10 19-3-10 6-3-10 26-3-0 6-11-6 27-3-0 1-0-0 0-5-55-10-50-4-15.00 12 Plate Offsets (X,Y)-- [1:0-1-4,0-2-3], [2:0-4-4,0-2-0], [3:0-1-0,0-1-8], [4:0-1-12,0-2-0], [4:0-2-0,0-0-9], [5:0-1-0,0-1-8], [6:0-4-4,0-2-0], [7:0-3-8,0-1-8], [11:0-1-8,0-1-8], [29:3-1-0 ,0-2-0], [46:3-1-0,0-2-0] LOADING (psf) TCLL (Roof Snow=25.0) TCDL BCLL BCDL 25.0 8.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.18 0.79 0.34 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.21 -0.30 0.08 (loc) 9-11 9-11 7 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 179 lb FT = 20% GRIP 185/148 LUMBER- TOP CHORD 2x4 DF No.1&Btr BOT CHORD 2x4 HF No.2 WEBS 2x4 HF Stud OTHERS 2x4 HF Stud SLIDER Left 2x4 DF No.1&Btr -t 6-9-1, Right 2x4 DF No.1&Btr -t 6-9-1 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-11-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=0-5-8, 7=0-5-8 Max Horz 1=-72(LC 11) Max Uplift 1=-62(LC 10), 7=-80(LC 11) Max Grav 1=1101(LC 3), 7=1170(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2235/136, 2-4=-1999/127, 4-6=-2025/127, 6-7=-2273/138 BOT CHORD 1-11=-137/2024, 9-11=-14/1261, 7-9=-72/2067 WEBS 2-11=-613/147, 4-11=-60/855, 4-9=-60/890, 6-9=-642/149 NOTES-(12) 1) Wind: ASCE 7-16; Vult=110mph (3-second gust) Vasd=87mph; TCDL=4.8psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pf=25.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 23.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 7.0psf. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 62 lb uplift at joint 1 and 80 lb uplift at joint 7. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) All dimensions given in feet-inches-sixteenths (FFIISS) format. March 5,2021 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719.Safety Information Job J1070180 Truss B1 Truss Type Common Girder Qty 1 Ply 2 MFour Contractors, LLC Job Reference (optional) I13684887 8.430 s Nov 30 2020 MiTek Industries, Inc. Fri Mar 5 13:11:48 2021 Page 1 The Truss Company (Sumner), Sumner, WA - 98390, ID:bVkDiYavCeF3Q1Shm7wAy6ycOfW-NkrIF_KPKUt6fWONAC57Yjij9eybvHV5ww1m24zdyw9 Scale: 3/8"=1' 1 2 3 4 5 9 8 7 6 10 11 12 13 14 15 16 17 18 19 4x10 6x6 4x10 7x8 WB8x8 4x5 3x8 4x5 3x8 MUS26 MUS26 MUS26 MUS26 MUS26 MUS26 MUS26 MUS26 MUS26 5-4-3 5-4-3 9-7-12 4-3-9 13-11-5 4-3-9 19-3-8 5-4-3 5-4-3 5-4-3 9-7-12 4-3-9 13-11-5 4-3-9 19-3-8 5-4-3 0-4-14-4-40-4-15.00 12 Plate Offsets (X,Y)-- [1:0-3-13,0-2-3], [2:0-1-12,0-1-12], [3:0-3-0,0-2-4], [4:0-1-12,0-1-12], [5:0-3-13,0-2-4], [6:0-4-8,0-1-8], [8:0-4-0,0-4-12], [9:0-4-8,0-1-8] LOADING (psf) TCLL (Roof Snow=25.0) TCDL BCLL BCDL 25.0 8.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.94 0.77 0.59 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.20 -0.33 0.07 (loc) 6-8 6-8 5 l/defl >999 >690 n/a L/d 360 240 n/a PLATES MT20 Weight: 171 lb FT = 20% GRIP 185/148 LUMBER- TOP CHORD 2x4 HF No.2 BOT CHORD 2x6 DF 2400F 2.0E WEBS 2x4 HF Stud *Except* 3-8: 2x4 HF No.2 OTHERS 2x4 HF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-3-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=0-5-8, 5=0-5-8 Max Horz 1=45(LC 10) Max Uplift 1=-584(LC 10), 5=-636(LC 11) Max Grav 1=5256(LC 16), 5=5692(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-11048/1225, 2-3=-7709/873, 3-4=-7710/873, 4-5=-11451/1275 BOT CHORD 1-9=-1136/10123, 8-9=-1136/10123, 6-8=-1137/10499, 5-6=-1137/10499 WEBS 3-8=-618/5593, 4-8=-3882/481, 4-6=-297/2808, 2-8=-3460/429, 2-9=-255/2474 NOTES-(13) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-4-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-16; Vult=110mph (3-second gust) Vasd=87mph; TCDL=4.8psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 4) TCLL: ASCE 7-16; Pf=25.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 23.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 584 lb uplift at joint 1 and 636 lb uplift at joint 5. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Load case(s) 18 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 11) Use USP MUS26 (With 6-10d nails into Girder & 6-10d nails into Truss) or equivalent spaced at 2-0-0 oc max. starting at 2-2-12 from the left end to 17-2-12 to connect truss(es) to front face of bottom chord. 12) Fill all nail holes where hanger is in contact with lumber. 13) All dimensions given in feet-inches-sixteenths (FFIISS) format.Continued on page 2 March 5,2021 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719.Safety Information Job J1070180 Truss B1 Truss Type Common Girder Qty 1 Ply 2 MFour Contractors, LLC Job Reference (optional) I13684887 8.430 s Nov 30 2020 MiTek Industries, Inc. Fri Mar 5 13:11:48 2021 Page 2 The Truss Company (Sumner), Sumner, WA - 98390, ID:bVkDiYavCeF3Q1Shm7wAy6ycOfW-NkrIF_KPKUt6fWONAC57Yjij9eybvHV5ww1m24zdyw9 LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-66, 3-5=-66, 1-5=-14 Concentrated Loads (lb) Vert: 6=-1036(F) 12=-1036(F) 13=-1036(F) 14=-1036(F) 15=-1036(F) 16=-1036(F) 17=-1036(F) 18=-1036(F) 19=-1036(F) 18) Dead: Lumber Increase=0.90, Plate Increase=0.90 Plt. metal=0.90 Uniform Loads (plf) Vert: 1-3=-16, 3-5=-16, 1-5=-14 Concentrated Loads (lb) Vert: 6=-389(F) 12=-389(F) 13=-389(F) 14=-389(F) 15=-389(F) 16=-389(F) 17=-389(F) 18=-389(F) 19=-389(F) WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719.Safety Information Job J1070180 Truss B2 Truss Type Common Qty 3 Ply 1 MFour Contractors, LLC Job Reference (optional) I13684888 8.430 s Nov 30 2020 MiTek Industries, Inc. Fri Mar 5 13:11:49 2021 Page 1 The Truss Company (Sumner), Sumner, WA - 98390, ID:bVkDiYavCeF3Q1Shm7wAy6ycOfW-rwPgSKK15o?zGgzZjwcM4wF1k1Kcep_E9ZmJaXzdyw8 Scale = 1:34.1 1 2 3 4 5 6 7 8 9 10 4x4 3x6 3x6 3x8 1.5x4 1.5x4 9-7-12 9-7-12 19-3-8 9-7-12 -1-0-0 1-0-0 5-1-12 5-1-12 9-7-12 4-6-0 14-1-12 4-6-0 19-3-8 5-1-12 20-3-8 1-0-0 0-4-14-4-40-4-15.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-8], [4:0-2-0,0-2-4], [6:0-3-0,0-1-8] LOADING (psf) TCLL (Roof Snow=25.0) TCDL BCLL BCDL 25.0 8.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.37 0.66 0.32 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.16 -0.29 0.04 (loc) 6-8 6-8 6 l/defl >999 >775 n/a L/d 360 240 n/a PLATES MT20 Weight: 65 lb FT = 20% GRIP 185/148 LUMBER- TOP CHORD 2x4 HF No.2 BOT CHORD 2x4 HF No.2 WEBS 2x4 HF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-2-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-5-8, 6=0-5-8 Max Horz 2=50(LC 10) Max Uplift 2=-63(LC 10), 6=-63(LC 11) Max Grav 2=894(LC 17), 6=894(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1594/109, 3-4=-1064/52, 4-5=-1064/52, 5-6=-1594/110 BOT CHORD 2-8=-104/1422, 6-8=-54/1422 WEBS 4-8=0/482, 5-8=-585/125, 3-8=-585/124 NOTES-(9) 1) Wind: ASCE 7-16; Vult=110mph (3-second gust) Vasd=87mph; TCDL=4.8psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=25.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 23.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 63 lb uplift at joint 2 and 63 lb uplift at joint 6. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) All dimensions given in feet-inches-sixteenths (FFIISS) format. March 5,2021 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719.Safety Information Job J1070180 Truss B2SR Truss Type Common Qty 1 Ply 1 MFour Contractors, LLC Job Reference (optional) I13684889 8.430 s Nov 30 2020 MiTek Industries, Inc. Fri Mar 5 13:11:49 2021 Page 1 The Truss Company (Sumner), Sumner, WA - 98390, ID:bVkDiYavCeF3Q1Shm7wAy6ycOfW-rwPgSKK15o?zGgzZjwcM4wF1k1Kcep_E9ZmJaXzdyw8 Scale = 1:34.1 1 2 3 4 5 6 7 8 9 10 4x4 3x6 3x6 3x8 1.5x4 1.5x4 9-7-12 9-7-12 19-3-8 9-7-12 -1-0-0 1-0-0 5-1-12 5-1-12 9-7-12 4-6-0 14-1-12 4-6-0 19-3-8 5-1-12 20-3-8 1-0-0 0-4-14-4-40-4-15.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-8], [4:0-2-0,0-2-4], [6:0-3-0,0-1-8] LOADING (psf) TCLL (Roof Snow=25.0) TCDL BCLL BCDL 25.0 8.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.37 0.66 0.32 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.16 -0.29 0.04 (loc) 6-8 6-8 6 l/defl >999 >775 n/a L/d 360 240 n/a PLATES MT20 Weight: 65 lb FT = 20% GRIP 185/148 LUMBER- TOP CHORD 2x4 HF No.2 BOT CHORD 2x4 HF No.2 WEBS 2x4 HF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-2-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-5-8, 6=0-5-8 Max Horz 2=50(LC 10) Max Uplift 2=-63(LC 10), 6=-63(LC 11) Max Grav 2=894(LC 17), 6=894(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1594/109, 3-4=-1064/52, 4-5=-1064/52, 5-6=-1594/110 BOT CHORD 2-8=-104/1422, 6-8=-54/1422 WEBS 4-8=0/482, 5-8=-585/125, 3-8=-585/124 NOTES-(9) 1) Wind: ASCE 7-16; Vult=110mph (3-second gust) Vasd=87mph; TCDL=4.8psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=25.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 23.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 63 lb uplift at joint 2 and 63 lb uplift at joint 6. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) All dimensions given in feet-inches-sixteenths (FFIISS) format. March 5,2021 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719.Safety Information Job J1070180 Truss B3 Truss Type GABLE Qty 1 Ply 1 MFour Contractors, LLC Job Reference (optional) I13684890 8.430 s Nov 30 2020 MiTek Industries, Inc. Fri Mar 5 13:11:50 2021 Page 1 The Truss Company (Sumner), Sumner, WA - 98390, ID:bVkDiYavCeF3Q1Shm7wAy6ycOfW-J6z2fgLfs67qupYlHd7bd8nGbRhoNGHNODWs7zzdyw7 Scale = 1:35.2 1 2 3 4 5 6 7 8 29 30 3x8 3x8 6x8 3x4 3x4 3x4 3x4 3x8 4x8 3x4 3x4 4x8 3x4 3x4 9-7-12 9-7-12 19-3-8 9-7-12 -1-0-0 1-0-0 5-1-12 5-1-12 9-7-12 4-6-0 14-1-12 4-6-0 19-3-8 5-1-12 20-3-8 1-0-0 0-4-14-4-40-4-15.00 12 Plate Offsets (X,Y)-- [2:0-2-8,0-1-8], [3:0-2-8,0-2-0], [4:0-5-8,0-2-4], [5:0-2-8,0-2-0], [6:0-2-8,0-1-8], [11:0-1-13,0-0-12], [23:0-1-13,0-0-12] LOADING (psf) TCLL (Roof Snow=25.0) TCDL BCLL BCDL 25.0 8.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.11 0.60 0.31 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.13 -0.23 0.04 (loc) 2-8 2-8 6 l/defl >999 >996 n/a L/d 360 240 n/a PLATES MT20 Weight: 114 lb FT = 20% GRIP 185/148 LUMBER- TOP CHORD 2x4 DF No.1&Btr BOT CHORD 2x4 HF No.2 WEBS 2x4 HF Stud OTHERS 2x4 HF Stud SLIDER Left 2x4 DF No.1&Btr -t 4-11-7, Right 2x4 DF No.1&Btr -t 4-11-7 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-5-8, 6=0-5-8 Max Horz 2=48(LC 14) Max Uplift 2=-63(LC 10), 6=-63(LC 11) Max Grav 2=894(LC 17), 6=894(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1614/104, 3-4=-1087/53, 4-5=-1089/52, 5-6=-1615/106 BOT CHORD 2-8=-97/1450, 6-8=-51/1451 WEBS 3-8=-581/115, 4-8=0/484, 5-8=-579/117 NOTES-(12) 1) Wind: ASCE 7-16; Vult=110mph (3-second gust) Vasd=87mph; TCDL=4.8psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pf=25.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 23.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 63 lb uplift at joint 2 and 63 lb uplift at joint 6. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) All dimensions given in feet-inches-sixteenths (FFIISS) format. March 5,2021 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719.Safety Information Job J1070180 Truss C1 Truss Type GABLE Qty 1 Ply 1 MFour Contractors, LLC Job Reference (optional) I13684891 8.430 s Nov 30 2020 MiTek Industries, Inc. Fri Mar 5 13:11:51 2021 Page 1 The Truss Company (Sumner), Sumner, WA - 98390, ID:bVkDiYavCeF3Q1Shm7wAy6ycOfW-nJXRt0MHcPFhWz7yrLeqALKRNrAo6npXctFQfPzdyw6 Scale = 1:24.4 1 2 3 4 5 6 7 8 9 10 18 17 16 15 14 13 12 11 19 3x4 3x4 3x4 -1-2-11 1-2-11 11-10-0 11-10-0 0-3-154-3-44.00 12 LOADING (psf) TCLL (Roof Snow=25.0) TCDL BCLL BCDL 25.0 8.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.11 0.04 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 -0.00 (loc) 1 1 11 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 51 lb FT = 20% GRIP 185/148 LUMBER- TOP CHORD 2x4 HF No.2 BOT CHORD 2x4 HF No.2 WEBS 2x4 HF Stud OTHERS 2x4 HF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 11-10-0. (lb) - Max Horz 2=118(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 11, 2, 18, 17, 16, 15, 14, 13, 12 Max Grav All reactions 250 lb or less at joint(s) 11, 2, 18, 17, 16, 15, 14, 13, 12 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(13) 1) Wind: ASCE 7-16; Vult=110mph (3-second gust) Vasd=87mph; TCDL=4.8psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pf=25.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 23.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 2, 18, 17, 16, 15, 14, 13, 12. 12) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 13) All dimensions given in feet-inches-sixteenths (FFIISS) format. March 5,2021 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719.Safety Information Job J1070180 Truss C2 Truss Type MONOPITCH Qty 9 Ply 1 MFour Contractors, LLC Job Reference (optional) I13684892 8.430 s Nov 30 2020 MiTek Industries, Inc. Fri Mar 5 13:11:52 2021 Page 1 The Truss Company (Sumner), Sumner, WA - 98390, ID:bVkDiYavCeF3Q1Shm7wAy6ycOfW-FV5p4LNvNjNY77i8P2A3iZsVvFSgr3IgrX?zBrzdyw5 Scale = 1:23.6 1 2 3 4 6 5 7 3x4 3x4 4x4 3x4 1.5x4 6-2-2 6-2-2 11-10-0 5-7-14 -1-2-11 1-2-11 6-2-2 6-2-2 11-10-0 5-7-14 0-3-154-3-44.00 12 Plate Offsets (X,Y)-- [5:0-1-12,0-1-8] LOADING (psf) TCLL (Roof Snow=25.0) TCDL BCLL BCDL 25.0 8.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.57 0.32 0.73 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.05 -0.09 0.02 (loc) 2-6 2-6 5 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 43 lb FT = 20% GRIP 185/148 LUMBER- TOP CHORD 2x4 HF No.2 BOT CHORD 2x4 HF No.2 WEBS 2x4 HF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=Mechanical, 2=0-3-8 Max Horz 2=118(LC 7) Max Uplift 5=-55(LC 10), 2=-76(LC 6) Max Grav 5=606(LC 17), 2=620(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1066/65 BOT CHORD 2-6=-81/957, 5-6=-81/957 WEBS 3-5=-1023/114 NOTES-(10) 1) Wind: ASCE 7-16; Vult=110mph (3-second gust) Vasd=87mph; TCDL=4.8psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=25.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 23.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 2. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) All dimensions given in feet-inches-sixteenths (FFIISS) format. March 5,2021 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719.Safety Information Job J1070180 Truss C3 Truss Type MONOPITCH Qty 1 Ply 1 MFour Contractors, LLC Job Reference (optional) I13684893 8.430 s Nov 30 2020 MiTek Industries, Inc. Fri Mar 5 13:11:53 2021 Page 1 The Truss Company (Sumner), Sumner, WA - 98390, ID:bVkDiYavCeF3Q1Shm7wAy6ycOfW-jhfBIhNX81VPlHHKymhIFmPfNfouaWIq4BkXjIzdyw4 Scale = 1:23.5 1 2 3 5 4 6 3x4 3x4 3x4 3x4 1.5x4 6-2-2 6-2-2 11-10-0 5-7-14 6-2-2 6-2-2 11-10-0 5-7-14 0-3-154-3-44.00 12 Plate Offsets (X,Y)-- [1:0-1-14,Edge], [4:0-1-12,0-1-8] LOADING (psf) TCLL (Roof Snow=25.0) TCDL BCLL BCDL 25.0 8.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.59 0.32 0.74 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.05 -0.09 0.02 (loc) 1-5 1-5 4 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 41 lb FT = 20% GRIP 185/148 LUMBER- TOP CHORD 2x4 HF No.2 BOT CHORD 2x4 HF No.2 WEBS 2x4 HF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-10-1 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=0-3-8, 4=Mechanical Max Horz 1=112(LC 7) Max Uplift 1=-39(LC 6), 4=-57(LC 10) Max Grav 1=525(LC 16), 4=611(LC 16) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1071/72 BOT CHORD 1-5=-86/978, 4-5=-86/978 WEBS 2-4=-1046/119 NOTES-(9) 1) Wind: ASCE 7-16; Vult=110mph (3-second gust) Vasd=87mph; TCDL=4.8psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=25.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 23.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) All dimensions given in feet-inches-sixteenths (FFIISS) format. March 5,2021 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719.Safety Information Job J1070180 Truss D1 Truss Type Common Qty 2 Ply 1 MFour Contractors, LLC Job Reference (optional) I13684894 8.430 s Nov 30 2020 MiTek Industries, Inc. Fri Mar 5 13:11:53 2021 Page 1 The Truss Company (Sumner), Sumner, WA - 98390, ID:bVkDiYavCeF3Q1Shm7wAy6ycOfW-jhfBIhNX81VPlHHKymhIFmPfJfqvaguq4BkXjIzdyw4 Scale = 1:19.0 1 2 3 4 5 3x4 4x4 3x4 1.5x4 4-7-8 4-7-8 9-4-8 4-9-0 4-7-8 4-7-8 9-4-8 4-9-0 10-4-8 1-0-0 0-4-112-3-130-4-15.00 12 LOADING (psf) TCLL (Roof Snow=25.0) TCDL BCLL BCDL 25.0 8.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.59 0.19 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.03 0.01 (loc) 3-5 3-5 3 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 26 lb FT = 20% GRIP 185/148 LUMBER- TOP CHORD 2x4 HF No.2 BOT CHORD 2x4 HF No.2 WEBS 2x4 HF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-8-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=0-3-8, 3=0-3-8 Max Horz 1=-31(LC 11) Max Uplift 1=-22(LC 10), 3=-38(LC 11) Max Grav 1=438(LC 17), 3=560(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-529/14, 2-3=-539/15 BOT CHORD 1-5=0/415, 3-5=0/415 NOTES-(9) 1) Wind: ASCE 7-16; Vult=110mph (3-second gust) Vasd=87mph; TCDL=4.8psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=25.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 23.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) All dimensions given in feet-inches-sixteenths (FFIISS) format. March 5,2021 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719.Safety Information Job J1070180 Truss D2 Truss Type COMMON Qty 1 Ply 1 MFour Contractors, LLC Job Reference (optional) I13684895 8.430 s Nov 30 2020 MiTek Industries, Inc. Fri Mar 5 13:11:54 2021 Page 1 The Truss Company (Sumner), Sumner, WA - 98390, ID:bVkDiYavCeF3Q1Shm7wAy6ycOfW-CtDZV1O9vKdGNRsWWTCXn_yrh283J77zJrU4Gkzdyw3 Scale = 1:21.1 1 2 3 4 5 6 4x4 3x4 3x4 1.5x4 4-9-0 4-9-0 9-6-0 4-9-0 -1-0-0 1-0-0 4-9-0 4-9-0 9-6-0 4-9-0 10-6-0 1-0-0 0-4-12-3-130-4-15.00 12 LOADING (psf) TCLL (Roof Snow=25.0) TCDL BCLL BCDL 25.0 8.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.55 0.19 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.03 0.01 (loc) 2-6 2-6 4 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 28 lb FT = 20% GRIP 185/148 LUMBER- TOP CHORD 2x4 HF No.2 BOT CHORD 2x4 HF No.2 WEBS 2x4 HF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-10-1 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 4=0-3-8 Max Horz 2=-27(LC 15) Max Uplift 2=-38(LC 10), 4=-38(LC 11) Max Grav 2=569(LC 17), 4=569(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-549/13, 3-4=-549/13 BOT CHORD 2-6=0/413, 4-6=0/413 NOTES-(9) 1) Wind: ASCE 7-16; Vult=110mph (3-second gust) Vasd=87mph; TCDL=4.8psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=25.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 23.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) All dimensions given in feet-inches-sixteenths (FFIISS) format. March 5,2021 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719.Safety Information Job J1070180 Truss D3 Truss Type GABLE Qty 1 Ply 1 MFour Contractors, LLC Job Reference (optional) I13684896 8.430 s Nov 30 2020 MiTek Industries, Inc. Fri Mar 5 13:11:55 2021 Page 1 The Truss Company (Sumner), Sumner, WA - 98390, ID:bVkDiYavCeF3Q1Shm7wAy6ycOfW-g4mxjNPogel7_bRj4AjmKBU7BSUA2aN7XVDdoAzdyw2 Scale = 1:21.1 1 2 3 4 5 63x10 3x10 4x8 3x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 4-9-0 4-9-0 9-6-0 4-9-0 -1-0-0 1-0-0 4-9-0 4-9-0 9-6-0 4-9-0 10-6-0 1-0-0 0-4-12-3-130-4-15.00 12 Plate Offsets (X,Y)-- [3:0-4-0,0-1-4] LOADING (psf) TCLL (Roof Snow=25.0) TCDL BCLL BCDL 25.0 8.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.12 0.20 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.03 0.01 (loc) 4-6 4-6 4 l/defl >999 >999 n/a L/d 360 240 n/a PLATES MT20 Weight: 44 lb FT = 20% GRIP 185/148 LUMBER- TOP CHORD 2x4 DF No.1&Btr BOT CHORD 2x4 HF No.2 WEBS 2x4 HF Stud OTHERS 2x4 HF Stud SLIDER Left 2x4 DF No.1&Btr -t 4-3-6, Right 2x4 DF No.1&Btr -t 4-3-6 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 4=0-3-8 Max Horz 2=-25(LC 11) Max Uplift 2=-38(LC 10), 4=-39(LC 11) Max Grav 2=568(LC 17), 4=569(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-577/12, 3-4=-578/12 BOT CHORD 2-6=0/451, 4-6=0/451 NOTES-(11) 1) Wind: ASCE 7-16; Vult=110mph (3-second gust) Vasd=87mph; TCDL=4.8psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pf=25.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 25.0 psf on overhangs non-concurrent with other live loads. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 23.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) All dimensions given in feet-inches-sixteenths (FFIISS) format. March 5,2021 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719.Safety Information Job J1070180 Truss V01 Truss Type GABLE Qty 1 Ply 1 MFour Contractors, LLC Job Reference (optional) I13684897 8.430 s Nov 30 2020 MiTek Industries, Inc. Fri Mar 5 13:11:55 2021 Page 1 The Truss Company (Sumner), Sumner, WA - 98390, ID:bVkDiYavCeF3Q1Shm7wAy6ycOfW-g4mxjNPogel7_bRj4AjmKBU4lSW42a47XVDdoAzdyw2 Scale = 1:25.7 1 2 3 4 5 8 7 6 9 10 3x4 4x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 16-0-8 16-0-8 8-0-4 8-0-4 16-0-8 8-0-4 0-0-43-4-20-0-45.00 12 LOADING (psf) TCLL (Roof Snow=25.0) TCDL BCLL BCDL 25.0 8.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.28 0.08 0.09 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 43 lb FT = 20% GRIP 185/148 LUMBER- TOP CHORD 2x4 HF No.2 BOT CHORD 2x4 HF No.2 OTHERS 2x4 HF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 16-0-8. (lb) - Max Horz 1=-34(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 8, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=278(LC 17), 8=489(LC 16), 6=489(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-423/88, 4-6=-423/88 NOTES-(9) 1) Wind: ASCE 7-16; Vult=110mph (3-second gust) Vasd=87mph; TCDL=4.8psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=25.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 23.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 8, 6. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) All dimensions given in feet-inches-sixteenths (FFIISS) format. March 5,2021 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719.Safety Information Job J1070180 Truss V02 Truss Type GABLE Qty 1 Ply 1 MFour Contractors, LLC Job Reference (optional) I13684898 8.430 s Nov 30 2020 MiTek Industries, Inc. Fri Mar 5 13:11:56 2021 Page 1 The Truss Company (Sumner), Sumner, WA - 98390, ID:bVkDiYavCeF3Q1Shm7wAy6ycOfW-8GKKwjQQRytzck?veuE?tP16JsqOn1YGm9zBKdzdyw1 Scale = 1:19.3 1 2 3 4 3x4 4x4 3x4 1.5x4 12-0-8 12-0-8 6-0-4 6-0-4 12-0-8 6-0-4 0-0-42-6-20-0-45.00 12 LOADING (psf) TCLL (Roof Snow=25.0) TCDL BCLL BCDL 25.0 8.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.80 0.20 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 29 lb FT = 20% GRIP 185/148 LUMBER- TOP CHORD 2x4 HF No.2 BOT CHORD 2x4 HF No.2 OTHERS 2x4 HF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=12-0-8, 3=12-0-8, 4=12-0-8 Max Horz 1=-25(LC 11) Max Uplift 1=-28(LC 10), 3=-33(LC 11) Max Grav 1=304(LC 16), 3=304(LC 17), 4=417(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-325/51 NOTES-(9) 1) Wind: ASCE 7-16; Vult=110mph (3-second gust) Vasd=87mph; TCDL=4.8psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=25.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 23.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) All dimensions given in feet-inches-sixteenths (FFIISS) format. March 5,2021 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719.Safety Information Job J1070180 Truss V03 Truss Type Valley Qty 1 Ply 1 MFour Contractors, LLC Job Reference (optional) I13684899 8.430 s Nov 30 2020 MiTek Industries, Inc. Fri Mar 5 13:11:57 2021 Page 1 The Truss Company (Sumner), Sumner, WA - 98390, ID:bVkDiYavCeF3Q1Shm7wAy6ycOfW-cSui73R2CF?qEua5BblEPcaPPGCaWVHP?piks3zdyw0 Scale = 1:14.7 1 2 3 4 3x4 4x4 3x4 1.5x4 0-0-10 0-0-10 8-0-8 7-11-14 4-0-4 4-0-4 8-0-8 4-0-4 0-0-41-8-20-0-45.00 12 LOADING (psf) TCLL (Roof Snow=25.0) TCDL BCLL BCDL 25.0 8.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.27 0.08 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 185/148 LUMBER- TOP CHORD 2x4 HF No.2 BOT CHORD 2x4 HF No.2 OTHERS 2x4 HF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=7-11-5, 3=7-11-5, 4=7-11-5 Max Horz 1=16(LC 14) Max Uplift 1=-18(LC 10), 3=-20(LC 11) Max Grav 1=178(LC 16), 3=178(LC 17), 4=259(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9) 1) Wind: ASCE 7-16; Vult=110mph (3-second gust) Vasd=87mph; TCDL=4.8psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=25.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 23.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) All dimensions given in feet-inches-sixteenths (FFIISS) format. March 5,2021 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719.Safety Information Job J1070180 Truss V04 Truss Type Valley Qty 1 Ply 1 MFour Contractors, LLC Job Reference (optional) I13684900 8.430 s Nov 30 2020 MiTek Industries, Inc. Fri Mar 5 13:11:57 2021 Page 1 The Truss Company (Sumner), Sumner, WA - 98390, ID:bVkDiYavCeF3Q1Shm7wAy6ycOfW-cSui73R2CF?qEua5BblEPcaT4GDwWVvP?piks3zdyw0 Scale = 1:7.5 1 2 3 3x4 3x6 3x4 3-11-14 3-11-14 4-0-8 0-0-10 2-0-4 2-0-4 4-0-8 2-0-4 0-0-40-10-20-0-45.00 12 Plate Offsets (X,Y)-- [2:0-3-0,Edge] LOADING (psf) TCLL (Roof Snow=25.0) TCDL BCLL BCDL 25.0 8.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.03 0.06 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 185/148 LUMBER- TOP CHORD 2x4 HF No.2 BOT CHORD 2x4 HF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=3-11-5, 3=3-11-5 Max Horz 1=-6(LC 15) Max Uplift 1=-6(LC 10), 3=-6(LC 11) Max Grav 1=107(LC 16), 3=107(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9) 1) Wind: ASCE 7-16; Vult=110mph (3-second gust) Vasd=87mph; TCDL=4.8psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=25.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 23.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) All dimensions given in feet-inches-sixteenths (FFIISS) format. March 5,2021 edge of truss.from outside"16/1-0PRODUCT CODE APPROVALSJOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3 - 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARINGLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T, I or Eliminator bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering System1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative T, I, or Eliminator bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal InjuryGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8dimensions shown in ft-in-sixteenths (Drawings not to scale)© 2006 MiTek® All Rights ReservedWEBSedge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ER-5243, 9604B,9730, 95-43, 96-31, 9667ANER-487, NER-56195110, 84-32, 96-67, ER-3907, 9432AJOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3 - 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARINGIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T, I or Eliminator bracingif indicated.4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8dimensions shown in ft-in-sixteenthsWEBS