7677 - Tahoma Blvd Apts - Equipment Submittal
FIRE SPRINKLER EQUIPMENT SUBMITTAL FOR TAHOMA BLVD APARTMENTS 15035 BERRY VALLEY ROAD SE YELM, WA 98597 FSI Job #7577 Table of Contents Section A - Pipe and Fittings 1. CPVC Pipe – Blazemaster 2. CPVC Pipe Fittings – Blazemaster Section B - Hangers 1. CPVC Pipe Hanger – Tolco Fig.’s 24, 28M, & 29 Section C - Valves 1. Riser Manifold – AGF Model 8011 (Residential 13R) 2. Backflow Preventer – Deringer 30 Double Check Detector Assembly 3. Fire Department Connection – FPPI Open Snoot 2½” Female x 2½” Female Section D - Fire Sprinklers 1. VK494 Residential Flat Concealed Pendent K4.9, 155°/200° - Viking 2. VK467 Residential Upright K4.9, 155° - Viking 3. VK178 Dry Horizontal Sidewall, K5.6 – Viking 4. RA1664 Extended Coverage Dry Horizontal Sidewall, K5.6 - Reliable Section E - Alarms and Supervisory Devices 1. Electric Bell – Potter Electric PB Series 2. Backer Box – Potter Electric SECTION A Pipe & Fittings BLAZEMASTER CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet Page 1 of 2 AUGUST 2018 TFP1915 Worldwide Contacts www.tyco-fire.com IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. General Description TYCO CPVC Pipe and Fittings pro- duced by Johnson Controls are designed exclusively for use in wet pipe automatic fire sprinkler systems. The TYCO CPVC Pipe and Fittings are produced from BLAZEMASTER CPVC compound that is a specially developed thermoplastic compound composed of post chlorinated polyvinyl chloride (CPVC) resin and state of the art addi- tives. TYCO CPVC Pipe and Fittings are easier to install than traditional steel pipe systems, and at the same time, provide superior heat resistance and strength as compared to traditional CPVC and PVC piping materials used in the plumbing trade. Various adapt- ers are available to connect CPVC pipe to metallic piping. All female pipe thread adapters have brass inserts for durability. Grooved adapters connect directly to grooved end valves and metallic pipe, with flexible grooved end couplings. NOTICE The CPVC Pipe and Fittings produced with BLAZEMASTER CPVC compound described herein must be installed and maintained in compliance with this document and with the applica- ble standards of the NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Technical Data Sizes 3/4 Inch to 3 Inch Maximum Working Pressure 175 psi Approvals UL and C-UL Listed FM Approved LPCB Approved NSF Certified MEA Approved (Refer to Installation Handbook IH-1900 dated April 2016 for exact listing/approval information.) Manufacture Source U.S.A. Material Pipe: ASTM F442, SDR 13.5 Fittings: ASTM F438 (Sch. 40) ASTM F439 (Sch. 80) ASTM F1970 Color Orange Installation TYCO CPVC Pipe and Fittings are to be to be installed in accordance with Installation Handbook IH-1900. TFP1915 Page 2 of 2 NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; BLAZEMASTER is a trademark of The Lubrizol Corporation 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 © 2018 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. Care and Maintenance TYCO CPVC Pipe and Fittings are to be maintained and serviced in accordance with this section. Before closing a fire protection system control valve for inspection or main- tenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must first be obtained from the proper authorities and all person- nel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central station alarms. The owner is responsible for the inspec- tion, testing, and maintenance of their fire protection system and de-vices in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSO- CIATION (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. Contact the installing con- tractor or product manufacturer with any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. CPVC BlazeMaster® Fire Protection Fittings 6 Form No. F_032219 19.12.05 Rev 19.3 Specifications and Engineering Data Introduction Viking BlazeMaster® CPVC fire sprinkler products are manufactured from high quality, post-chlorinated polyvinyl chloride (CPVC), a specialty thermoplastic material tested and listed by certifying agencies for use in CPVC fire sprinkler systems. Viking CPVC fire sprinkler products provide unique advantages over traditional metal fire sprinkler systems through superior hydraulics, ease of installation, handling, and quicker assembly using readily available and less expensive tools. These products are also based on technology with a continuous and proven service history of more than forty (40) years. Pressure Rating Viking BlazeMaster® fittings of nominal sizes 3/4" – 3" (20 – 80 mm) are rated for continuous service of 175 psi (1270 kPa) at 150°F (65°C). Approvals Viking BlazeMaster® fittings for fire sprinkler systems »Listed by Underwriters Laboratories (UL) for the United States and Canada under Chlorinated Polyvinyl Chloride Sprinkler Pipe and Fittings - VIWT and VIWT7.EX15419 »FM Global approved for FM Global Group insured properties - Class 1635-Plastic Pipe & Ftngs AS Sys »Meets approval and listing requirements of NFPA 13, 13D, and 13R »Red Book listed by the Loss Prevention Safety Board (LPCB) under automatic sprinkler, water spray and deluge systems - Certificate 1558a to LPS 1260-2.2 »CPVC fittings and Brastic® sprinkler adapters are NSF International listed to NSF/ANSI-61 (health effects) and NSF/ANSI-372 (Lead Free*) for use in potable water applications Nibco BlazeMaster® fittings for fire sprinkler systems »Listed by Underwriters Laboratories (UL) for the United States and Canada under Chlorinated Polyvinyl Chloride Sprinkler Pipe and Fittings - VIWT and VIWT7.EX6309 »Red Book listed by the Loss Prevention Safety Board (LPCB) under automatic sprinkler, water spray and deluge systems - Certificate 878a to LPS 1260-2.2 Use with other Manufacturers' Pipes, Fittings, & Solvent Cements Viking BlazeMaster® CPVC fire sprinkler products are listed by UL to standard 1821. They are also approved by FM to standard 1635. These standards require rigorous testing to ensure the products will function as a component of the assembled fire protection system. For fire protection CPVC pipe the current UL standard is 1821 and FM standard 1635. Viking warrants each Viking BlazeMaster® fitting installed in accordance with local code and regulations with UL listed and/or FM approved CPVC pipe and fittings in compliance with the UL & FM standards. A current list of compatible UL and ULC listed CPVC manufacturers are: Viking (pipe), Harvel (pipe), TYCO Fire Products (pipe & fittings), IPEX (pipe & fittings) and Spears (pipe & fittings). NOTICE: While Viking BlazeMaster® CPVC fire sprinkler products are UL listed for use in combination with other listed manufacturers' products, specific application approvals may not be the same among manufacturers. It is the installer's responsibility to verify suitability of products used in combination according to each manufacturer's installation instructions. Contact Viking if you have questions on any application not addressed in this manual. Engineering Data – Product Specifications Viking BlazeMaster® CPVC fire sprinkler products are made for use with listed CPVC fire sprinkler pipe produced in SDR 13.5 dimensions, as specified in ASTM F442. Viking BlazeMaster® CPVC fire sprinkler fittings are produced in schedule 40 dimensions for sizes 3/4 inch (20 mm) through 1-1/4 inch (32 mm) in accordance with ASTM F438 and schedule 80 dimensions for sizes 1-1/2 inch (40 mm) through 3 inch (80 mm) in accordance with ASTM F439. These products are cULus listed, and FM Approved for a rated working pressure of 175 psi (1200 kPa) at 150°F (65°C) for sprinkler service. Installation Instructions For complete installation instructions refer to the Viking "Installation and Design Manual" on www.vikinggroupinc.com. *Weighted average lead content <0.25%. CPVC FIRE SPRINKLER FITTING 7TA2 8 Form No. F_032219 19.12.05 Rev 19.3 ADAPTERS Grooved Coupling Adapters (G x S) BlazeMaster® Fire Protection Fittings – STANDARD V5001-G Univ. Fig. No. Nominal Size Approx. Wght. Dimensions JointABC IN.mm lb.kg IN.mm IN.mm IN.mm V5001-G 1-1/4 33 0.17 0.08 0.83 21 1.04 26 2.98 76 GXS V5001-G 1-1/2 40 0.2 0.09 0.95 24 1.17 30 3.15 80 GXS V5001-G 2 50 0.3 0.14 1.18 30 1.43 36 3.37 86 GXS V5001-G 2-1/2 65 0.52 0.24 1.43 36 1.74 44 3.66 93 GXS V5001-G --65 0.52 0.24 1.43 36 1.74 44 3.66 93 GXS V5001-G 3 75 0.72 0.33 3.5 89 --------GXS Univ. Fig. No. Nominal Size Approx. Wght. Dimensions JointLN IN.mm lb.kg IN.mm IN.mm V5018 1x3/4 25x19 0.04 0.02 1.28 33 0.29 7 SPGXS V5018 1-1/4x1 31x25 0.08 0.04 1.41 36 0.29 7 SPGXS V5018 1-1/4x3/4 31x19 0.10 0.05 1.41 36 0.41 10 SPGXS V5018 1-1/2x1-1/4 40x31 0.07 0.03 1.54 39 0.27 7 SPGXS V5018 1-1/2x1 40x25 0.12 0.05 1.54 39 0.39 10 SPGXS V5018 1-1/2x3/4 40x19 0.16 0.07 1.54 39 0.53 13 SPGXS V5018 2x1-1/2 50x40 0.16 0.07 1.66 42 0.27 7 SPGXS V5018 2x1-1/4 50x31 0.20 0.09 1.66 42 0.4 10 SPGXS V5018 2x1 50x25 0.22 0.10 1.66 42 0.52 13 SPGXS V5018 2x3/4 50x19 0.22 0.10 1.66 42 0.64 16 SPGXS V5018 2-1/2x2 65x50 0.24 0.11 1.94 49 0.44 11 SPGXS V5018 2-1/2x1-1/2 65x40 0.36 0.16 1.94 49 0.57 14 SPGXS V5018 2-1/2x1-1/4 65x31 0.40 0.18 1.94 49 0.68 17 SPGXS V5018 2-1/2x1 65x25 0.47 0.21 1.94 49 0.81 21 SPGXS V5018 3x2-1/2 75x65 0.47 0.21 2.42 61 0.6 15 SPGXS V5018 3x2 75x50 0.66 0.30 2.42 61 0.93 24 SPGXS V5018 3x1-1/2 75x40 0.73 0.33 2.42 61 1.03 26 SPGXS BUSHINGS Bushings V5018 9Form No. F_032219 19.12.05 Rev 19.3 Univ. Fig. No. Nominal Size Approx. Wght.Dimension A Joint IN.mm lb.kg IN.mm V5017 3/4"19 0.04 0.02 0.31 8 S V5017 1"25 0.06 0.03 0.39 10 S V5017 1-1/4"31 0.22 0.1 0.56 14 S V5017 1-1/2"40 0.3 0.14 0.68 17 S V5017 2"50 0.42 0.19 0.68 17 S V5017 2-1/2"65 0.62 0.28 1.2 30 S V5017 3"75 0.96 0.44 1.26 32 S Univ. Fig. No. Nominal Size Approx. Wght.Dimension A Joint IN.mm lb.kg IN.mm V5001 3/4 19 0.06 0.03 0.12 3 SXS V5001 1 25 0.08 0.04 0.09 2 SXS V5001 1-1/4 31 0.12 0.05 0.08 2 SXS V5001 1-1/2 40 0.23 0.1 0.27 7 SXS V5001 2 50 0.44 0.2 0.28 7 SXS V5001 2-1/2 65 0.72 0.33 0.2 5 SXS V5001 3 75 1.1 0.5 0.22 6 SXS V5001-R 1x3/4 25x19 0.08 0.04 0.29 7 SXS V5001-R 1-1/4x1 31x25 0.12 0.05 0.35 9 SXS V5001-R 1-1/2x1-1/4 40x31 0.38 0.17 0.51 13 SXS V5001-R 1-1/2x1 40x25 0.36 0.16 0.67 17 SXS V5001-R 1-1/2x3/4 40x19 0.34 0.15 0.8 20 SXS V5001-R 2x1-1/2 50x40 0.49 0.22 0.51 13 SXS V5001-R 2x1 50x25 0.48 0.22 0.75 19 SXS BlazeMaster® Fire Protection Fittings – STANDARD Caps V5017 CAPS Couplings V5001 V5001-R COUPLINGS CROSSES Crosses V5035 V5035-R Univ. Fig. No. Nominal Size Approx. Wght. Dimensions JointLN IN.mm lb.kg IN.mm IN.mm V5035 3/4 19 0.12 0.05 0.61 15 0.61 15 SXSXSXS V5035 1 25 0.24 0.11 0.75 19 0.75 19 SXSXSXS V5035 1-1/4 31 0.34 0.15 0.9 23 0.9 23 SXSXSXS V5035 1-1/2 40 0.87 0.39 1.23 31 1.23 31 SXSXSXS V5035 2 50 1.43 0.65 1.53 39 1.53 39 SXSXSXS V5035 2-1/2 65 2.17 0.98 1.75 44 1.75 44 SXSXSXS V5035 3 75 3.12 1.42 1.89 48 1.89 48 SXSXSXS V5035-R 1x1x3/4x3/4 25x25x19x19 0.18 0.08 0.61 15 0.73 19 SXSXSXS 10 Form No. F_032219 19.12.05 Rev 19.3 BlazeMaster® Fire Protection Fittings – STANDARD ELBOWS 45° Elbows V5006 90° Elbows V5007 V5007-R Univ. Fig. No. Nominal Size Approx. Wght.Dimension J Joint IN.mm lb.kg IN.mm V5006 3/4 19 0.06 0.03 0.32 8 SXS V5006 1 25 0.12 0.05 0.39 10 SXS V5006 1-1/4 31 0.18 0.08 0.48 12 SXS V5006 1-1/2 40 0.36 0.16 0.47 12 SXS V5006 2 50 0.54 0.24 0.58 15 SXS V5006 2-1/2 65 1 0.45 0.65 17 SXS V5006 3 75 1.28 0.57 0.76 19 SXS Univ. Fig. No. Nominal Size Approx. Wght. Dimensions JointLN IN.mm lb.kg IN.mm IN.mm V5007 3/4 19 0.08 0.04 0.56 14 0.56 14 SXS V5007 1 25 0.14 0.06 0.69 18 0.69 18 SXS V5007 1-1/4 31 0.22 0.10 0.91 23 0.91 23 SXS V5007 1-1/2 40 0.41 0.18 1.06 27 1.06 27 SXS V5007 2 50 0.83 0.37 1.24 31 1.24 31 SXS V5007 2-1/2 65 1.16 0.52 1.5 38 1.5 38 SXS V5007 3 75 1.66 0.74 1.81 46 1.81 46 SXS V5007-R 1x3/4 25x19 0.12 0.05 0.61 15 0.75 19 SXS 11Form No. F_032219 19.12.05 Rev 19.3 TEES BlazeMaster® Fire Protection Fittings – STANDARD Tees V5011 Note: All Viking reducing tees are molded to size, not fabricated. V5011-R Univ. Fig. No. Nominal Size Approx. Wght. Dimensions JointABC IN.mm lb.kg IN.mm IN.mm IN.mm V5011 3/4 19 0.1 0.04 0.57 14 0.57 14 0.57 14 SXSXS V5011 1 25 0.17 0.08 0.69 18 0.69 18 0.69 18 SXSXS V5011 1-1/4 33 0.28 0.12 0.89 23 0.89 23 0.89 23 SXSXS V5011 1-1/2 40 0.58 0.26 1.05 27 1.05 27 1.05 27 SXSXS V5011 2 50 0.82 0.37 1.25 32 1.25 32 1.25 32 SXSXS V5011 2-1/2 65 1.4 0.62 1.53 39 1.53 39 1.53 39 SXSXS V5011 3 75 2.14 0.96 1.84 47 1.84 47 1.84 47 SXSXS V5011-R 3/4x3/4x1 19x19x25 0.14 0.06 0.7 18 0.7 18 0.73 19 SXSXS V5011-R 1x1x3/4 25x25x19 0.16 0.07 0.61 15 0.61 15 0.94 24 SXSXS V5011-R 1x3/4x1 25x19x25 0.2 0.09 0.76 19 0.99 25 0.78 20 SXSXS V5011-R 1x3/4x3/4 25x19x19 0.16 0.07 0.6 15 0.87 22 0.77 20 SXSXS V5011-R 1-1/4x1-1/4x1 33x33x25 0.24 0.11 0.73 19 0.73 19 0.89 23 SXSXS V5011-R 1-1/4x1-1/4x3/4 33x33x19 0.2 0.09 0.6 15 0.6 15 0.89 23 SXSXS V5011-R 1-1/4x1x1-1/4 33x25x33 0.28 0.12 0.88 22 1.03 26 0.87 22 SXSXS V5011-R 1-1/4x1x1 33x25x25 0.24 0.11 0.71 18 0.9 23 0.89 23 SXSXS V5011-R 1-1/4x1x3/4 33x25x19 0.2 0.09 0.61 15 0.76 19 0.89 23 SXSXS V5011-R 1-1/4x1-1/4x1-1/2 33x33x45 0.44 0.2 1.01 26 1.01 26 0.88 22 SXSXS V5011-R 1-1/2x1-1/2x1-1/4 45x45x33 0.46 0.21 0.89 23 0.89 23 1.04 26 SXSXS V5011-R 1-1/2x1-1/2x1 40x40x25 0.54 0.24 0.77 20 0.77 20 0.96 24 SXSXS V5011-R 1-1/2x1-1/2x3/4 40x40x19 0.5 0.22 0.67 17 0.67 17 1.04 26 SXSXS V5011-R 1-1/2x1-1/4x1 40x33x25 0.4 0.18 0.72 18 0.91 23 1.01 26 SXSXS V5011-R 1-1/2x1-1/4x3/4 40x33x19 0.36 0.16 0.6 15 0.78 20 1.02 26 SXSXS V5011-R 1-1/2x1-1/2x2 40x40x50 0.66 0.29 1.3 33 1.3 33 1.14 29 SXSXS V5011-R 2x2x1-1/2 50x50x40 0.86 0.38 1.06 27 1.06 27 1.37 35 SXSXS V5011-R 2x2x1-1/4 50x50x33 0.67 0.3 1 25 1 25 1.28 33 SXSXS V5011-R 2x2x1 50x50x25 0.72 0.32 0.8 20 0.8 20 1.25 32 SXSXS V5011-R 2x2x3/4 50x50x19 0.68 0.3 0.7 18 0.7 18 1.25 32 SXSXS V5011-R 2-1/2x2-1/2x2 65x65x50 1.32 0.59 1.26 32 1.26 32 1.53 39 SXSXS V5011-R 2-1/2x2-1/2x1-1/2 65x65x40 1.21 0.54 1.06 27 1.06 27 1.53 39 SXSXS V5011-R 2-1/2x2-1/2x1-1/4 65x65x33 1.12 0.5 0.91 23 0.91 23 1.53 39 SXSXS V5011-R 2-1/2x2-1/2x1 65x65x25 1.05 0.47 0.74 19 0.74 19 1.53 39 SXSXS V5011-R 3x3x2-1/2 75x75x65 1.71 0.76 1.53 39 1.53 39 1.84 47 SXSXS V5011-R 3x3x2 75x75x50 1.91 0.85 1.26 32 1.26 32 1.84 47 SXSXS V5011-R 3x3x1-1/2 75x75x40 1.39 0.62 1.06 27 1.06 27 1.82 46 SXSXS 18 Form No. F_032219 19.12.05 Rev 19.3 BlazeMaster® Fire Protection Fittings – THREADED INSTASEAL ADAPTERS Sprinkler Adapters with Metal Thread Insert and EPDM Rubber Seat Sprinkler Adapters with Metal Thread Insert and EPDM Rubber Seat V5003-S-BG V5003-2-S-BG Figure 1: Sprinkler Contact on Rubber Seat Univ. Fig. No. Nominal Size Approx. Wght.Dimension A Joint IN.mm lb.kg IN.mm V5003-S-BG 3/4 X 1/2 19x13 1.50 38 C x FNPSH V5003-S-BG 1 X 1/2 25x13 1.88 48 C x FNPSH Univ. Fig. No.Nominal Size Approx. Wght.Dimension A Joint IN.mm lb.kg IN.mm V5003-2-S-BG 3/4 X 1/2 19x13 1.50 38 FTG x FNPSH V5003-2-S-BG 1 X 1/2 25x13 1.85 47 FTG x FNPSH INSTASEAL ADAPTER INSTALLATION INSTRUCTIONS NOTICE InstaSeal adapters can only be used with sprinklers having a K-factor less than or equal to 5.8 (83.6 metric). Pendent and Upright Sprinklers 1. Follow BlazeMaster one-step solvent cement instructions for socket or spigot fittings. Never complete a solvent cement joint with the sprinkler installed into the Instaseal fitting per NFPA 13 requirements. DO NOT OVER APPLY CEMENT WHERE IT COULD OVER SPILL TO RUBBER SEAT. Installer must be properly trained and certified for construction and assembly of BlazeMaster® CPVC piping systems. 2. After proper cure time of cement, make sure sealing surface of rubber is clean and free of any nicks or scratches on sprinkler seal end surface. Use only the thumb and forefinger (finger strength) to start the sprinkler in the lead thread of the Instaseal sprinkler adapter continuing until sprinkler contacts rubber seat. The rubber seat should not be compressed during this step. (Note: also include accessories as supplied by sprinkler manufacturer, such as adjustable cups and escutcheons, on to sprinkler prior to installing sprinkler into adapter fitting.) OK x NO Deformity of rubber seat Brass Insert EPDM Seat CPVC 19Form No. F_032219 19.12.05 Rev 19.3 Tightening torque from touch of sprinkler to seat for proper installation of sprinkler ½ turn CW 14-19 IN-LBS Minimum ¾ turn CW 24-30 IN-LBS Recommended 1¼ turns CW 50-60 IN-LBS Maximum NOTE: Torque values are shown as “Inch-pounds” and not “foot-pounds”. 3. Using sprinkler manufacturer’s recommended wrench, turn sprinkler clockwise (CW) a minimum of one half (½) turn for seal. If sprinkler frame arms require alignment with pipe, continue to rotate CW additional to align, up to the maximum of 1¼ turns from initial seat to sprinkler contact as stated and as shown in Figure 1. NOTICE Do not tighten more than 1¼ turns from initial sprinkler touch to rubber seat. Over-tightening will cause the rubber seat to protrude into the waterway and reduce the K-factor which impedes flow. Additionally, permaent damage to the rubber seat will occur leading to failure and leakage. Refer to Figure 1. Horizontal Sidewall Sprinklers Overview: Horizontal sidewall sprinklers require a specific position including the deflector in the top position and horizontal to the ceiling. Due to the random starting point of threads on both the sprinklers and the adapter fittings it is required that special attention be given to installation of the horizontal sidewall sprinklers. During the initial assembly (Step 2), note the deflector position. If deflector is greater than ½ turn from final position in proper horizontal position, rotate CW only enough to position sprinkler deflector in proper Horizontal position. If deflector position is less than ½ turn to proper position then rotate CW one full turn plus to proper position, maximum 1¼ turns from sprinkler touch of seat. Use proper manufacturer’s sprinkler wrench. 1. Solvent Cement Joining Follow BlazeMaster one-step solvent cement instructions for socket or spigot fittings. Never complete a solvent cement joint with the sprinkler installed into Instaseal fitting per NFPA 13 requirements. DO NOT OVER APPLY CEMENT WHERE IT COULD OVER SPILL TO RUBBER SEAT. Installer must be properly trained and certified for construction and assembly of BlazeMaster Piping system. 2. After proper cure time of cement, make sure sealing surface of rubber is clean and free of any nicks or scratches on sprinkler seal end surface. Use only the thumb and forefinger (finger strength) to start the sprinkler in the lead thread of the Instaseal sprinkler adapter continuing until sprinkler contacts rubber seat. The rubber seat should not be compressed during this step. (Note: also include accessories as supplied by sprinkler manufacturer, such as adjustable cups and escutcheons, on to sprinkler prior to installing sprinkler into adapter fitting.) 3. Determine Sprinkler Position Take note of the position of the sprinkler deflector in relation to the final required position. Determine whether greater or less than one quarter (½) turn is required to reach the required final position. Turn the sprinkler CW with proper sprinkler wrench as required by sprinkler manufacturer. Rotate only to the position where the sprinkler deflector is in the required final installed position. TOP Required Final Position See the manufacturer’s installation instructions for proper location and distance from ceiling. Fig1: HSW Final 12 O’clock Position 3A: Seal and position sprinkler when the top of the delfecltor is in the 12 O’clock position through the 9 O’clock position. 20 Form No. F_032219 19.12.05 Rev 19.3 NOTICE Do not tighten more than 1¼ turns from initial sprinkler touch to rubber seat. Over-tightening will damage the rubber seat causing long term deformation which will lead to failure and leakage. 3B: Seal and position sprinkler when the top of the deflector is between the 9 o’clock position and the 12 o’clock position. Rotate CW 3/4 turnRotate CW 1 full turn Rotate CW 1/2 turn Position of the HSW sprinkler when finger tight and sprinkler is just touching the EPDM rubber seat. Seat the sprinkler and position the deflector by rotating clockwise as indicated above from the position of sprinkler at finger tight touch of EPDM rubber seat initial installation. NOTICE Do not tighten more than 1¼ turns from initial sprinkler touch to rubber seat. Over-tightening will damage the rubber seat causing long term deformation which will lead to failure and leakage. NOTE: For standard horizontal sidewall sprinklers the deflector position holds true as described above. Turn the sprinkler clockwise with the proper sprinkler wrench as required by sprinkler manufacturer. Rotate one full turn plus positioning sprinkler deflector into final required position Fig2: HSW at 12 O’clock through 9 O’clock position. Rotate CW 1 full turn plus to position the top at the 12 O’clock position. Position of the HSW sprinkler when finger tight and sprinkler is just touching the EPDM rubber seat. Seat the sprinkler and position the deflector by rotating clockwise as indicated above from the position of sprinkler at finger tight touch of EPDM rubber seat initial installation. Fig3: HSW at greater than 9 O’clock and less than 12 O’clock position. 22 Form No. F_032219 19.12.05 Rev 19.3 Review – Do's & Don'ts Do’s »Installation should be made only by a qualified installer or contractor in accordance with all applicable codes and requirements. »Read and follow the installation instructions. »Follow recommended safe work practices. »Make certain thread sealants, gasket lubricants, and firestop materials are compatible with CPVC. »Keep pipe and fittings in original packaging until needed. »Cover pipe and fittings with an opaque tarp if stored outdoors. »Follow proper handling procedures. »Use tools specifically designed for use with plastic pipe and fittings. »Use the proper solvent cement and follow application instructions. »Use a drop cloth to protect interior finishes. »Cut the pipe ends square. »Deburr and bevel the pipe end with a chamfering tool. »Rotate the pipe 1/4 turn when bottoming pipe in fitting socket. »Make certain no solvent cement is on sprinkler and adapter threads. »Make certain that solvent cement does not run and plug the sprinkler orifice. »Follow the manufacturer’s recommended cure times prior to pressure testing. »Fill lines slowly and only at a proper pressure. »Bleed the air from the system prior to pressure testing. »Support sprinkler properly to prevent lift up of the through the ceiling when activated. »For threaded rod hangar supports keep within 1/16” near pipe or use surge arrestor. »Install Viking BlazeMaster ® CPVC fire sprinkler products in wet or dry system applications. »Use only insulation and/or glycerin and water solutions for freeze protection. »Allow for movement due to expansion and contraction. »Ensure installers have been properly trained per the Viking BlazeMaster ® CPVC Fire Sprinkler System Installation and Design Manual and renew training every three years at a minimum. Don’ts »Do not use edible oils as a gasket lubricant. »Do not use petroleum or solvent-based sealants, lubricants, or fire stop materials. »Do not use any glycol-based solutions as anti-freeze. »Do not contaminate the CPVC system with cutting oils or compressor oils. »Do not mix glycerin and water solutions in contaminated containers. »Do not use solvent cement that exceeds its shelf life or has become discolored or jellied. »Do not allow solvent cement to plug the sprinkler orifice. »Do not connect rigid metal couplers to CPVC grooved adapters. »Do not thread or groove CPVC pipe. »Do not use solvent cement near sources of heat, open flame, or when smoking. »Do not pressure test with air. »Do not pressure test until recommended cure times are met. »Do not exceed proper pressure for testing. »Do not use ratchet cutters below 50°F. »Do not use CPVC pipe that has been stored outdoors, unprotected and is faded in color. »Do not allow threaded rod to come in contact with the pipe. »Do not install Viking BlazeMaster ® CPVC fire sprinkler products in cold weather without allowing for expansion. »Do not allow puddling of cement in fittings and pipe. »Do not use dull or broken cutting tool blades when cutting pipe. SECTION B Hangers and Sway Bracing CPVC Clamps 35 Eaton All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Fire Protection Solutions CPVC Clamps TOLCO™Fig. 24 - Hanger for CPVC Plastic Pipe & IPS Steel Pipe Double Fastener Strap Side Mounted (B-Line B3183) Size Range:3/4" (20mm)thru 2" (50mm)CPVC pipe Material:Pre-Galvanized Steel Function:Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. Approvals:Underwriters Laboratories Listed in the USA (UL)and Canada (cUL)to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge (0.912mm)steel using (2) 1/4" x 1" tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features:Fig. 24 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws* furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish:Pre-Galvanized Order By:Figure number and pipe size * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. C A B B CPVC Max. Hanger Fastener Hex Approx. Pipe Size ABCSpacing Head Size Wt./100 Part No.in. (mm) in. (mm) in. (mm) in. (mm) Ft. (m)in. (mm)Lbs. (kg) 24-3/4 3/4"(20)25/16"(58.7)15/32"(27.8)13/16"(30.2)51/2 (1.67)5/16"(7.9)9 (4.1) 24-1 1"(25)25/8"(66.7)15/16"(33.3)13/16"(30.2)6 (1.83)5/16"(7.9)9 (4.1) 24-11/4 11/4"(32)3"(76.2)11/2"(38.1)13/16"(30.2)61/2 (1.98)5/16"(7.9)11 (5.0) 24-11/2 11/2"(40)31/4"(82.5)15/8"(42.3)13/16"(30.2)7 (2.13)5/16"(7.9)12 (5.4) 24-2 2"(50)311/16"(93.7)127/32"(43.6)13/16"(30.2)8 (2.44)5/16"(7.9)15 (6.8) IPS Max. Hanger Pipe Size Spacing Part No.in. (mm) Ft. (m) 24-3/4 3/4"(20)1’-9”(1.67) 24-1 1"(25)1’-10”(1.83) 24-11/4 11/4"(32)2-4”(1.98) 24-11/2 11/2"(40)2-9”(2.13) 24-2 2"(50)3-6”(2.44) Reduced Spacing For IPS Pipe CPVC Clamps All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 38 B-Line series Fire Protection SolutionsEatonCPVC Clamps TOLCO™Fig. 28M - Offset Hanger & Restrainer for CPVC Plastic Pipe and IPS Steel Pipe Size Range:3/4"(20mm)thru 2"(32mm) Material:Steel, Pre-Galvanized Function:Designed to be used as a hanger and restrainer for CPVC piping or steel piping where the “stand-off” design will ease installation by eliminating the need for wood blocking. Features: • Flared edge design protects CPVC pipe from any rough or abrasive surfaces • Unique snap-on design holds pipe firmly in place and allows retrofit type of installation • The “Stand-Off” design eliminates the need for wood block extension • Can be installed on horizontal or vertical piping regardless of mounting surface orientation • Attaches easily to wood structure with two hex head self-threading screws furnished with product • Installs easily using rechargeable electrical driver with 5/16”(7.9mm)extension socket eliminating impact tool damage to pipe • Attaches easily to steel, minimum 18 gauge (1.024mm)with (2) 1/4” x 1” tek type self drilling tapping screws • (cULus)Listed as a hanger and a restrainer for fire sprinkler piping Installation Note:When installed in wood structural members and threads from the #10 x 1" screws are exposed, use Fig. 27B (page 36) speed nut to secure Approvals:Underwriters Laboratory Listed in the USA (UL)and Canada (cUL) to support automatic fire sprinkler systems. May be installed into wood using fasteners screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28M satisfies the UL vertical restraint requirements where needed. Order By:Figure number and pipe size Patent #7,744,042 C A B CPVC Pipe Size A Hole Dia. B C Max Spacing* Approx. Wt./100 Part No.in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kg) 28M-3/4 3/4"(20)2"(50.8)3/16"(4.8)35/16"(84.1)5’-6”(1676)9 (4.1) 28M-1 1"(25)21/8"(54.0)3/16"(4.8)31/2"(88.9)6’-0”(1829)12 (5.4) 28M-11/4 11/4"(32)25/16"(58.7)3/16"(4.8)31/2"(88.9)6’-6”(1981)13 (5.9) 28M-11/2 11/2"(49)27/16"(61.9)3/16"(4.8)37/8"(98.4)7’-0”(2133)14 (6.3) 28M-2 2"(50)25/8"(66.7)3/16"(4.8)47/16"(112.7)8’-0”(2438)15 (6.8) * Required per NFPA 13 for CPVC plastic pipe Hanger and Restraint Application Restraint Restraint Detail A Hanger Application Fig. 27B (2) Required Fig. 27B (1) Required High Side of Hanger IPS Pipe Size Max. Hanger Spacing Part No.in. (mm)Ft. (m) 28-3/4 3/4"(20)1’-9”(1.67) 28-1 1"(25)1’-10”(1.83) 28-11/4 11/4"(32)2-4”(1.98) 28-11/2 11/2"(40)2-9”(2.13) 28-2 2"(50)3-6”(2.44) Reduced Spacing For IPS Pipe CPVC Clamps All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 40 B-Line series Fire Protection SolutionsEatonCPVC Clamps TOLCO™Fig. 29 - Double Offset Hanger & Restrainer for CPVC Plastic Pipe & IPS Steel Pipe Size Range:Available in 3/4"(20mm)and 1"(25mm)pipe sizes Material:Pre-Galvanized Steel Function:Intended to perform as a hanger and restrainer for CPVC, plastic fire sprinkler pipe. Provides double offset 11/2”(20mm)x 11/2”(20mm)from mounting surface. This design will ease installation by eliminating the need for wood block extension and allow retro-fit attachment of hanger to sprinkler pipe. Features: • Thumb tab provides protection to restrain pipe in rough job site conditions. Tab is not required to be bent for listed installation. • Offset edge eliminates abrasion. • Attaches easily to wood structure with two special #10 x 1” hex head self-threading screws furnished with product. • Can be used as a single offset hanger by aligning "dimples" with top of mounting surface and utilizing two fasteners in two of the three holes provided. Approvals:Underwriters Laboratories Listed in the USA (UL)and Canada (cUL)as a hanger and restrainer to support fire sprinkler systems. Meets and exceeds requirements of NFPA 13, 13R and 13D. Finish:Pre-Galvanized Order By:Figure number and pipe size. Patent Pending Install using a rechargeable electric drill fitted with a 5/16” (7.9mm)socket attachment with the special hex head self-tapping screws provided. Install screws until they bottom out. Pipe can be “snapped” into hanger before or after installation of the screws to the mounting surface. “Thumb tab” may be bent up to provide additional protection to the pipe, but is not required for performance of the hanger / restrainer function. Double Offset Single Offset 1.5” (38.1mm) 1.5” (38.1mm) 1.5” (38.1mm) 1.5” (38.1mm) CPVC Max Hanger Approx. Pipe size Spacing Wt./100 Part No.in. (mm) Ft. (m) lbs. (kg) 29-3/4 3/4"(20) 5’-6”(1.67)18 (8.1) 29-1 1"(25) 6’-0”(1.83)19 (8.6) IPS Max. Hanger Pipe Size Spacing Part No.in. (mm) Ft. (m) 29-3/4 3/4"(20)1’-9”(1.67) 29-1 1"(25)1’-10”(1.83) Reduced Spacing For IPS Pipe SECTION C Valves BR-RP_2017 · 1/17Ri s e R PACK™ Floor Control Assemblies for Residential and Commercial Wet Fire Sprinkler Systems Reliability, Versatility, Code Compatibility AGF Manufacturing Inc. Ri s e r PACK™ TESTa n DRAIN® is a registered trademark of AGF Manufacturing Inc. 2 AGF Manufacturing’s Re s i d e n t i a l and Co m m e r c i a l Ri s e R PACK™ Floor Control Assemblies offer the ultimate in conve- nience, versatility, and reliability. The Model 8000 Ri s e R PACK™ Floor Control Assembly includes a pressure gauge, water flow switch, In s P e C t o R ’sTEST™, and drain valve. They can be ordered with a Pressure Relief Kit as the Model 8011. Ri s e R PACK™ Floor Control Assemblies meet the requirements of NFPA 13D, NFPA 13R, and NFPA 13 for wet fire sprinkler systems, and can be assembled with additional features to meet custom specifications. SAVE MONEY, SAVE TIME, SAVE SPACE Ri s e R PACK™ Floor Control Assemblies cut the cost of buying and assembling the individual parts of a sectional floor control, reduce the space used by sectional floor controls by up to 75%, and are installed in a fraction of the time. Ri s e r PACK™ Features: Full Range of Connection Sizes• Multiple Connection Types• NFPA Compliant• UL Listed/FM Approved Components • UL Listed Bronze Manifolds• Vertical or Horizontal Installation• Left or Right Side Operation• Made in the USA• TABLE OF CONTENTS Re s i d e n t i a l Ri s e r PACK™ for NFPA 13D M8000 13D ........................................4-7 M8011 13D ........................................4-7 Re s i d e n t i a l Ri s e r PACK™ for NFPA 13R M8000 13R ......................................8-11 M8011 13D ......................................8-11 Co m m e r c i a l Ri s e r PACK™ for NFPA 13 M8000 ............................................12-17 M8011 ............................................12-17 Simplify Your Floor Control with AGF Ri s e R PACK™ Pre-Assembled to Your Specifications AGF Manufacturing Inc. • Phone: 610-240-4900 • Fax: 610-240-4906 • www.testandrain.com 3 re s i d e n t i a l ri s e r PACK™ for NFPA 13R NFPA 13R Ri s e R PACK™ Floor Control Assemblies are designed to meet NFPA 13R requirements for residential wet fire sprinkler systems in multi-family dwellings. M8000 13R M8011 13R Co m m e r C i a l ri s e r PACK™ for NFPA 13 NFPA 13 Ri s e R PACK™ Floor Control Assemblies are de- signed to meet NFPA 13 requirements for commercial wet fire sprinkler systems in commercial buildings. M8000 M8011 re s i d e n t i a l ri s e r PACK™ for NFPA 13D NFPA 13D Ri s e R PACK™ Floor Control Assemblies are designed to meet NFPA 13D requirements for residential wet fire sprinkler systems in family dwellings. M8000 13D M8011 13D Ri s e r PACK™ TESTa n DRAIN® is a registered trademark of AGF Manufacturing Inc. 4 Application Model Size Connection 1 & 2 Family dwellings and manufactured homes 8000 8011 1”THD X THD 8000 8011 1¼”THD X THD 8000 8011 1½” THD X THD THD X GRV GRV X GRV 8000 8011 2” THD X THD THD X GRV GRV X GRV re s i d e n t i a l ri s e r PACK™ for NFPA 13D Systems The core of a re s i d e n t i a l Ri s e R PACK™ is the bronze riser manifold designed to fit in standard stud wall framing. The riser provides all required signage for flow direction, test and drain outlet, and pressure gauge location. Lettering appears on both sides allowing for right or left installation. 13D Ri s e R PACK™ Floor Control Assemblies are available in 4 sizes and 3 different connection combinations. NOTE: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to OPEN in a range of pressure between 90% and 105% of their rating. The valves are required to CLOSE at a pressure above 80% of that rating. The relief valve should be installed where it is easily accessible for maintenance. Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational. A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. 1¼" M8000 13D THD X THD 1" M8000 13D THD X THD AGF Manufacturing Inc. • Phone: 610-240-4900 • Fax: 610-240-4906 • www.testandrain.com 5 Model 8011 13D 2” THD X THD 12 4 5 3 Features 1. riser Re s i d e n t i a l Ri s e R PACK™ manifolds are cast bronze with THD X THD, THD X GRV, or GRV X GRV connections. 2. Pressure Gauge Re s i d e n t i a l Ri s e R PACK™ Floor Control Assemblies feature a FM Approved, UL Listed AGF Model 7500 Pressure Gauge. The Model 7500 is a 3½” pressure gauge with a ¼” threaded connection. 3. Water Flow Alarm Switch Re s i d e n t i a l Ri s e R PACK™ Floor Control Assemblies feature a Water Flow Alarm Switch with a 1” threaded connection. 4. In s P e C t o R ’sTEST™ The Model 3011 In s P e C t o R ’sTEST™ provides both, TEST and DRAIN functions in a single compact valve. They are FM Approved, UL Listed, and designed to meet NFPA 13D requirements. Available orifice sizes include: 3⁄8”, 7⁄16”, ½”, 17⁄32”, and 5⁄8” (ELO). The Model 3011 In s P e C t o R ’sTEST™ is rated for 300 PSI and features a 1” female NPT connection. 5. Pressure Relief Valve The Model 8011 Re s i d e n t i a l Ri s e R PACK™ Floor Control Assembly features an AGF Model 7000 Pressure Relief Valve for systems requiring pressure relief. The Model 7000 Pressure Relief Valve is designed for wet fire sprinkler systems with 175 PSI ratings (also available: 165, 185, 195, 205, 225, and 250 PSI ratings) and is designed to be easily installed without draining the system. Models include bypass piping and all necessary fittings. Ri s e r PACK™ TESTa n DRAIN® is a registered trademark of AGF Manufacturing Inc. 6 *+7 0%9 model 8000d re s i d e n t i a l ri s e r PACK™ for NFPA 13D (No PRV) Installation Requirements model 8011d re s i d e n t i a l ri s e r PACK™ for NFPA 13D Installation Requirements *+7 0$ M8000 13D — 1” THD X THD Orifice: 3.0k-A • 3.7k-B • 4.3k-C • 5.5k-D M8011 13D — 1” THD X THD M8000 13D — 1¼” THD X THD Orifice: 3⁄8" • 7⁄16" • ½" • 17⁄32" • 5⁄8" ELO Orifice: 3⁄8" • 7⁄16" • ½" • 17⁄32" • 5⁄8" ELO M8011 13D — 1¼” THD X THD Orifice: 3.0k-B • 3.7k-E • 4.3k-F • 5.5k-F PRV Ratings: 165 • 175 • 185 • 195 • 205 • 225 • 250 PRV Ratings: 165 • 175 • 185 • 195 • 205 • 225 • 250 AGF Manufacturing Inc. • Phone: 610-240-4900 • Fax: 610-240-4906 • www.testandrain.com 7 0%9 0%9 0$ 0$ M8000 13D — 1½” THD X THD M8000 13D — 1½” THD X THD Orifice: 3⁄8" • 7⁄16" • ½" • 17⁄32" • 5⁄8" ELO Orifice: 3⁄8" • 7⁄16" • ½" • 17⁄32" • 5⁄8" ELO Orifice: 3⁄8" • 7⁄16" • ½" • 17⁄32" • 5⁄8" ELO Orifice: 3⁄8" • 7⁄16" • ½" • 17⁄32" • 5⁄8" ELO M8000 13D — 2” THD X THD M8000 13D — 2” THD X THD PRV Ratings: 165 • 175 • 185 • 195 • 205 • 225 • 250 PRV Ratings: 165 • 175 • 185 • 195 • 205 • 225 • 250 Ri s e r PACK™ TESTa n DRAIN® is a registered trademark of AGF Manufacturing Inc. 8 re s i d e n t i a l ri s e r PACK™ for NFPA 13R Systems The core of a re s i d e n t i a l Ri s e R PACK™ is the bronze riser manifold designed to fit in standard stud wall framing. The riser provides all required signage for flow direction, test and drain outlet, and pressure gauge location. Lettering appears on both sides allowing for right or left installation. 13R Ri s e R PACK™ Floor Control Assemblies are available in 3 sizes and 3 different connection combinations. NOTE: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to OPEN in a range of pressure between 90% and 105% of their rating. The valves are required to CLOSE at a pressure above 80% of that rating. The relief valve should be installed where it is easily accessible for maintenance. Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational. A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. Application Model Size Connection Multi-family occupancies up to and including four stories 8000 8011 1¼”THD X THD 8000 8011 1½” THD X THD THD X GRV GRV X GRV 8000 8011 2" THD X THD THD X GRV GRV X GRV 1½" M8000 13R THD X THD 1½" M8011 13R THD X THD AGF Manufacturing Inc. • Phone: 610-240-4900 • Fax: 610-240-4906 • www.testandrain.com 9 1 2 45 6 3 Features 1. riser Re s i d e n t i a l Ri s e R PACK™ manifolds are cast bronze with THD X THD, THD X GRV, or GRV X GRV connections. 2. Pressure Gauge Ri s e R PACK™ Floor Control Assemblies feature a FM Approved, UL Listed AGF Model 7500 Pressure Gauge. The Model 7500 is a 3½” pressure gauge with a ¼” threaded connection. 3. Water Flow Alarm Switch Ri s e r PACKS™ feature a Water Flow Alarm Switch with a 1” threaded connection. 4. In s P e C t o R ’sTEST™ The Model 3011 In s P e C t o R ’sTEST™ provides both, TEST and DRAIN functions in a single compact valve. They are FM Approved, UL Listed, and designed to meet NFPA 13R requirements. Available orifice sizes include: 3⁄8”, 7⁄16”, ½”, 17⁄32”, and 5⁄8” (ELO). The Model 3011 In s P e C t o R ’sTEST™ is rated for 300 PSI and features a 1” female NPT connection. 5. Pressure Relief Valve The Model 8011 Re s i d e n t i a l Ri s e R PACK™ Floor Control Assembly features an AGF Model 7000 Pressure Relief Valve for systems requiring pressure relief. The Model 7000 Pressure Relief Valve is designed for wet fire sprinkler systems with 175 PSI ratings (also available: 165, 185, 195, 205, 225, and 250 PSI ratings) and is designed to be easily installed without draining the system. Models include bypass piping and all necessary fittings. 6. Shutoff Valve NFPA 13R Ri s e R PACK™ Floor Control Assemblies feature a Shutoff Valve for isolating the Pressure Gauge for maintenance. Model 8011 13R 2” THD X THD Ri s e r PACK™ TESTa n DRAIN® is a registered trademark of AGF Manufacturing Inc. 10 0%9 0%9 0$ 0$ model 8000r re s i d e n t i a l ri s e r PACK™ for NFPA 13R (No PRV) Installation Requirements model 8011r re s i d e n t i a l ri s e r PACK™ for NFPA 13R Installation Requirements M8000 13R — 1¼” THD X THD M8011 13R — 1¼” THD X THD M8000 13R — 1½” THD X THD M8011 13R — 1½” THD X THD PRV Ratings: 165 • 175 • 185 • 195 • 205 • 225 • 250 PRV Ratings: 165 • 175 • 185 • 195 • 205 • 225 • 250 Orifice: 3⁄8" • 7⁄16" • ½" • 17⁄32" • 5⁄8" ELOOrifice: 3⁄8" • 7⁄16" • ½" • 17⁄32" • 5⁄8" ELO Orifice: 3⁄8" • 7⁄16" • ½" • 17⁄32" • 5⁄8" ELO Orifice: 3⁄8" • 7⁄16" • ½" • 17⁄32" • 5⁄8" ELO AGF Manufacturing Inc. • Phone: 610-240-4900 • Fax: 610-240-4906 • www.testandrain.com 11 0%9 0$ M8000 13R — 2” THD X THD M8011 13R — 2” THD X THD PRV Ratings: 165 • 175 • 185 • 195 • 205 • 225 • 250 Orifice: 3⁄8" • 7⁄16" • ½" • 17⁄32" • 5⁄8" ELO Orifice: 3⁄8" • 7⁄16" • ½" • 17⁄32" • 5⁄8" ELO Ri s e r PACK™ TESTa n DRAIN® is a registered trademark of AGF Manufacturing Inc. 12 Co m m e r C i a l ri s e r PACK™ for NFPA 13 Systems The core of a co m m e r c i a l Ri s e R PACK™ is the U.S. made, cast bronze or powder-coated, schedule 40 steel riser manifold. All risers are rated at 300 PSI and allow for right or left and vertical or horizontal installation. Co m m e r c i a l Ri s e R PACK™ Floor Control Assemblies are available in 7 sizes and 3 different connection combinations. Application Model Size Connection Commercial Buildings 8000 8011 1¼”THD X THD 8000 8011 1½” THD X THD THD X GRV GRV X GRV 8000 8011 2" THD X THD THD X GRV GRV X GRV 8000 8011 2½"GRV X GRV 8000 8011 3"GRV X GRV 8000 8011 4"GRV X GRV 8000 8011 6"GRV X GRV NOTE: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to OPEN in a range of pressure between 90% and 105% of their rating. The valves are required to CLOSE at a pressure above 80% of that rating. The relief valve should be installed where it is easily accessible for maintenance. Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational. A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. REVIT files available at www.testandrain.com 4" M8000 Steel GRV X GRV 2" M8011 Bronze THD X GRV 2" M8000 Bronze THD X THD 4" M8011 Steel GRV X GRV AGF Manufacturing Inc. • Phone: 610-240-4900 • Fax: 610-240-4906 • www.testandrain.com 13 Features 1. riser Co m m e r c i a l Ri s e R PACK™ manifold sizes 1¼”-2” are cast bronze with THD X THD, THD X GRV, or GRV X GRV connections. Sizes 2½”-6” are domestically-made, schedule 40 steel with 3 mil powder-coat finish and GRV X GRV connections. 2. Pressure Gauge All Ri s e R PACK™ models feature AGF’s Model 7500 Pressure Gauge. The Model 7500 is a UL listed, FM approved, 3½” pres- sure gauge with a ¼” threaded connection attached with a Model 7600 Shutoff Valve for NFPA compliance. 3. Water Flow Alarm Switch Co m m e r c i a l Ri s e R PACK™ models feature a water flow alarm switch with a 1” threaded connection for 1¼”-2” sizes, and a saddle connection for 2½”-6” sizes. 4. TESTa n DRAIN® The AGF TESTA n DRAIN® is the key feature of the Co m m e r c i a l Ri s e R PACK™. The TESTA n DRAIN® combines the test and drain function in a single ball valve and features an NFPA required orifice available in a full range of sizes (3⁄8”, 7⁄16”, ½”, 17⁄32”, 5⁄8”, and ¾”). The TESTA n DRAIN® valve is specifically designed so that all servicing can be easily performed through the valve without removing it from the system. 5. Pressure Relief Valve The Ri s e R PACK™ Model 8011 features an AGF Model 7000 Pressure Relief Valve for systems requiring pressure relief. The Model 7000 Pressure Relief Valve is designed for wet fire sprinkler systems with 175 PSI ratings (also available: 165, 185, 195, 205, 225, and 250 PSI ratings) and is designed to be easily installed without draining the system. Includes bypass piping and all necessary fittings. 6. Shutoff Valve Co m m e r c i a l Ri s e R PACK™ models feature a Shutoff Valve which isolates the Pressure Gauge for inspection and maintenance. 1 2 4 5 6 3 Model 8011 2” GRV X GRV Ri s e r PACK™ TESTa n DRAIN® is a registered trademark of AGF Manufacturing Inc. 14 Model 8000 Co m m e r C i a l ri s e r PACK™ for NFPA 13 Installation Requirements 0 0 0 0 0 M8000 — 3” GRV X GRV M8000 — 4” GRV X GRV M8000 — 1¼” THD X THD M8000 — 1½” THD X THD Orifice: 3⁄8" • 7⁄16" • ½" • 17⁄32" • 5⁄8" ELOOrifice: 3⁄8" • 7⁄16" • ½" • 17⁄32" • 5⁄8" ELO Orifice: 3⁄8" • 7⁄16" • ½" • 17⁄32" • 5⁄8" ELO • ¾" ESFR Orifice: 3⁄8" • 7⁄16" • ½" • 17⁄32" • 5⁄8" ELO • ¾" ESFR • K25 AGF Manufacturing Inc. • Phone: 610-240-4900 • Fax: 610-240-4906 • www.testandrain.com 15 0 0 0 M8000 — 6” GRV X GRV M8000 — 2” THD X THD M8000 — 2½” THD X THD Orifice: 3⁄8" • 7⁄16" • ½" • 17⁄32" • 5⁄8" ELO Orifice: 3⁄8" • 7⁄16" • ½" • 17⁄32" • 5⁄8" ELO • ¾" ESFR Orifice: 3⁄8" • 7⁄16" • ½" • 17⁄32" • 5⁄8" ELO • ¾" ESFR • K25 Ri s e r PACK™ TESTa n DRAIN® is a registered trademark of AGF Manufacturing Inc. 16 Model 8011 Co m m e r C i a l ri s e r PACK™ for NFPA 13 Installation Requirements 0$ 0$ 0$ 0$ M8011 — 3” GRV X GRV M8011 — 4” GRV X GRV M8011 — 1¼” THD X THD M8011 — 1½” THD X THD Orifice Sizes: 3.0k-B • 3.7k-E • 4.3k-F • 5.5k-F PRV Ratings: 165 • 175 • 185 • 195 • 205 • 225 • 250 PRV Ratings: 165 • 175 • 185 • 195 • 205 • 225 • 250 PRV Ratings: 165 • 175 • 185 • 195 • 205 • 225 • 250PRV Ratings: 165 • 175 • 185 • 195 • 205 • 225 • 250 Orifice Sizes: 3⁄8" • 7⁄16" • ½" • 17⁄32" • 5⁄8" ELO Orifice Sizes: 3⁄8" • 7⁄16" • ½" • 17⁄32" • 5⁄8" ELOOrifice Sizes: 3⁄8" • 7⁄16" • ½" • 17⁄32" • 5⁄8" ELO AGF Manufacturing Inc. • Phone: 610-240-4900 • Fax: 610-240-4906 • www.testandrain.com 17 0$ 0$ 0$ M8011 — 6” GRV X GRV M8011 — 2” THD X THD M8011 — 2½” THD X THD PRV Ratings: 165 • 175 • 185 • 195 • 205 • 225 • 250 PRV Ratings: 165 • 175 • 185 • 195 • 205 • 225 • 250 PRV Ratings: 165 • 175 • 185 • 195 • 205 • 225 • 250 Orifice Sizes: 3⁄8" • 7⁄16" • ½" • 17⁄32" • 5⁄8" ELO Orifice Sizes: 3⁄8" • 7⁄16" • ½" • 17⁄32" • 5⁄8" ELO Orifice Sizes: 3⁄8" • 7⁄16" • ½" • 17⁄32" • 5⁄8" ELO Ames Fire & Waterworks product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measure- ments, please contact Ames Fire & Waterworks Technical Service. Ames Fire & Waterworks reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames Fire & Waterworks products previously or subsequently sold. DeringerTM 30 Double Check Detector Assembly Sizes: 2"** – 8" Job Name –––––––––––––––––––––––––––––––––––––––––––– Contractor –––––––––––––––––––––––––––––––––––––––––––– Job Location –––––––––––––––––––––––––––––––––––––––––– Approval –––––––––––––––––––––––––––––––––––––––––––––– Engineer ––––––––––––––––––––––––––––––––––––––––––––– Contractor’s P.O. No. ––––––––––––––––––––––––––––––––––– Approval ––––––––––––––––––––––––––––––––––––––––––––– Representative ––––––––––––––––––––––––––––––––––––––––– The DeringerTM 30 Double Check Detector Assembly (DCDA-II) prevents non-health hazard pollutants from entering a potable water supply system when backpressure and/or backsiphonage conditions occur. Used primarily on fire sprinkler systems when monitoring of unauthorized water use is required. Features • Integral shutoff valves indoor/outdoor application • 100% stainless steel housing • Tamper-resistant test cocks • Patented Dual-actionTM check modules - Poppet action at low flow - Swing action at high flow • Lead Free* Bronze bypass components • CuFt or gallons bypass meter • DCDA-II single check bypass • Silicone elastomer check discs • Prewired supervisory switches • Flange adapters available • IPS grooved ends Specifications The Deringer 30 Double Check Detector Assembly shall utilize two independent Dual-action check modules and two integral resiliently seated shut-off valves all of which shall be contained within a single rigid valve housing constructed entirely of 304 stainless steel. Both integral shutoff valves shall include pre-wired supervisory tamper switches contained within a weatherproof actuator housing approved for both indoor and outdoor use. Dual-action check modules shall operate as a “poppet style” check under low flow conditions, operate as a “swing style” check under high flow conditions and utilize replaceable silicone elastomer sealing discs. Assembly test cocks shall be handle-less and operate via a tamper resistant actuator. Assembly shall have a single full access service port and cover with an “inline” replaceable elastomer seal. The bypass assembly shall include a meter registering either gallons or cubic feet, a single check valve and required test cocks. Assembly shall be serviceable without special tools and approved for both horizontal and vertical applications. LEAD FREE* *The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight. The information contained herein is not intended to replace the full product installa- tion and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product. NOTICE ES-A-Deringer 30 HORIZONTAL VERTICALApproved for Fire Protection, Waterworks, Plumbing, and Irrigation Applications. Materials Valve Housing: 304 Stainless Steel Valve Cover: 304 Stainless Steel SOV Disks: EPDM/304SS SOV Shafts: 304 Stainless Steel Bypass Spring 302 Stainless Steel SOV Bearings: Teflon® fluoropolymer/Bronze Non-wetted Bolts: Grade 8 Zinc Plated Check Disks: Silicone (NSF) Wetted Fasteners: 18-8 Stainless Steel Bypass Components: Lead Free Bronze Check Springs: 17-7 Stainless Steel Check Pins: 17-7/18-8 Stainless Steel Check Seats: Noryl® Polymer (NSF) O-rings: Buna-N (NSF) Bypass Internals: ABS Polymer (NSF) Pressure — Temperature Temperature Range: 33°F – 140°F Working Pressure: 10 – 175psi Teflon® is a registered trademark of The Chemours Company. Noryl® is a registered trademark of SABIC Global Technologies B.V. Size Model Ht Hb L D H W Weight ES-A-Deringer 30 1951 © 2020 Watts USA: Backflow T: (978) 689-6066 • F: (978) 975-8350 • AmesFireWater.com USA: Control Valves T: (713) 943-0688 • F: (713) 944-9445 • AmesFireWater.com Canada: T: (905) 332-4090 • F: (905) 332-7068 • AmesFireWater.ca Latin America: T: (52) 55-4122-0138 • AmesFireWater.com Dimensions — Weights Flow Performance in.in.mm in.mm in.mm in.mm in.mm in.mm lbs kg 2 (21⁄2)**30 7.1 180 2.9 74 22.3 566 0.0 0 10.0 254 11.0 279 52 24 21⁄2 30 7.1 180 2.9 74 18.7 475 0.0 0 10.0 254 11.0 279 47 21 3 30 7.4 188 2.9 74 18.7 475 0.0 0 10.3 262 11.0 279 49 22 4 30 7.9 201 3.1 79 18.7 475 0.2 5 11.0 279 11.0 279 51 23 6 30 10.1 257 4.5 114 25 726 1.0 25 14.6 370 16.9 429 99 45 8 30 10.4 264 5.4 137 31.0 787 1.8 46 15.8 401 13.8 351 150 68 Ht Hb D L H WPressure Loss (psid)Pressure Loss (psid)* Specific orientation & agency flow characteristics available on website * Specific orientation & agency flow characteristics available on website Rate of Flow (gpm) Rate of Flow (gpm) Standards AWWA C510-07 Compliant NSF/ANSI 372, UL CERTIFIED LEAD FREE End Connections - IPS Groove for Steel Pipe: AWWA C606 - Flange Adapters: ANSI B16.1 Class 125 = Rated Flow = UL Tested = 15 fps 2½"/2"** **2" size utilizes a 2 ½" assembly with 2 ½" groove to 2" female NPT adapter and couplings. Adapter and couplings ship unassembled. Specifications Material: B16 Brass* CAUTION: 11/2 FNPT x FNST 11/2 FNPT x 21/2 FNST* 2 FNPT x 21/2 FNST* 21/2 FNPT x FNST* 3 FNPT x 21/2 FNST* 3 FNPT x 3 FNST *Swivels: NST 3.0686 x 71/2 TPI BCT 3.0000 x 8 TPI CF 2.9900 x 71/2 TPI CIN-new 3.0580 x 6 TPI CIN-old 3.0930 x 6 TPI CLV 3.0780 x 8 TPI Dayton 3.2340 x 6 TPI DET 3.1250 x 71/2 TPI NovaSco 3.2300 x 5 TPI NYFD 3.0300 x 8 TPI ONT 3.1250 x 5 TPI PHX 3.0620 x 6 TPI QST 3.0310 x 7 TPI Raleigh 3.3400 x 6 TPI Richmon 3.3120 x 8 TPI TEM 3.0750 x 6 TPI *Contains lead. Not for use in water systems intended for human consumption. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1 760 599-1168 + 1 800 344-1822 FAX + 1 800 344-3775 © 2015 Fire Protection Products, Inc. Description The single outlet open snoot is constructed of cast brass*. The single swivel is complete with gasket and comes standard with pin lugs. Configured with FNPT x FNST swivel. (Plug with chain and breakable caps. Sold Separately) Installation Installation can be achieved with tools readily available in the field using common installation practices. Make sure male threads of pipe to which the snoot is being attached are liberally coated with a pipe thread sealant such as PipeFit Thread Sealant with PTFE or PTFE Thread Sealant Tape. Tighten the snoot until hand tight. Tighten one additional turn past hand tight to achieve a water tight seal of the threads. DO NOT OVER TIGHTEN! Over Tightening may cause thread failure as well as cracking of the snoot body. WWW.FPPI.COM Open Snoot Female X Female Swivel Connection SECTION D Fire Sprinklers FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9)TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 1 of 6 Form No. F_012116 20.06.26 Rev 20.2 1. DESCRIPTION Viking Freedom® Residential Concealed Pendent Sprinkler VK494 is a small thermosensitive, glass-bulb residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design, with a K-factor of 4.9 (70.6 metric*), allows the sprinkler’s efficient use of available water supplies for the hydraulically designed fire-protection system. The fast response glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. The sprinkler is pre-assembled with a threaded adapter for installation with a low-profile small-diameter cover assembly installed flush to the ceiling. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The “push-on” and “thread-on” designs of the concealed cover plate assemblies allow easy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to 1/2” (13 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL-US-EU Listed as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. 2. LISTINGS AND APPROVALS cULusEU Listed: Category VKKW Refer to the Approval Charts and Design Criteria for C-UL-US-EU Listing requirements that must be followed. 3. TECHNICAL DATASpecifications:Minimum Operating Pressure: Refer to the Approval Chart.Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar).Thread size: 1/2” (15 mm) NPT Nominal K-factor: 4.9 U.S. (70.6 metric*)Glass-bulb fluid temperature rating: to -65 °F (-55 °C) * Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards:Sprinkler Body: Brass UNS-C84400 or QM BrassDeflector: Phosphor Bronze UNS-C51000Deflector Pins: Stainless Steel UNS-S30200Button: Brass UNS-C36000Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400Compression Screw: 18-8 Stainless SteelYoke: Phosphor Bronze UNS-C51000Belleville Spring Sealing Assembly: Beryllium Nickel Alloy, coated on both sides with PTFE TapeCover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc PlatingShipping Cap: High Density Polyethylene Cover Plate Materials:Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 or Stainless Steel UNS-S30400Spring: Beryllium NickelSolder: Eutectic Ordering Information: The sprinkler and cover plate must be ordered separately. Refer to Tables 1 and 2. 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches the cover plate’s nominal temperature rating, the cover plate detaches and releases the deflector. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand. When the temperature reaches the sprinkler’s nominal temperature rating, the glass bulb shatters releasing the yoke, pip cap assembly and sealing spring. Water begins flowing through the sprinkler orifice and strikes the deflector form-ing a uniform spray pattern over a specific area of coverage, which is determined by the water supply pressure at the sprinkler, in order to extinguish or control the fire. Replaces Form No. F_012116 Rev 20.1 (Added cover plate options.) FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9)TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 2 of 6 Form No. F_012116 20.06.26 Rev 20.2 6. INSPECTIONS, TESTS AND MAINTENANCERefer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinkler Model VK494 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEEFor details of warranty, refer to Viking’s current list price schedule or contact Viking directly. TABLE 1: SPRINKLER ORDERING INFORMATION Instructions: (1) Select a Sprinkler Base Part Number (2) Add the suffix for the desired Finish (3) Add the suffix for the desired Sprinkler Temperature Rating (4) Order a cover plate (refer to Table 2) Example: 20759AE = 200 °F (93 °C) Temperature Rated Sprinkler with a standard Brass finish. Sprinkler Base Part Number1 Size 1: Finishes 2: Temperature Ratings7 NPT Inch Description Suffix Nominal Rating Bulb Color Max. Ambient Ceiling Temperature2 Suffix 20759 1/2 Brass A 155 °F (68 °C)Red 100 °F (38 °C)B ENT5,6 JN 200 °F (93 °C)Green 150 °F (65 °C)E Corrosion Resistant Sprinkler Finish: ENT Accessories Sprinkler Wrenches and tools: A. Heavy Duty Part Number: 14047W/B3 (available since 2006) B. Head Cabinet Wrench Part Number: 140313,4 (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part Number: 144128 (available since 2007) D. Optional Large Concealed Cover Plate Installer Tool Part No. 148678 (available since 2007) Sprinkler Cabinet: Holds up to 6 sprinklers: Part number 01731A (available since 1971). Footnotes 1. Part number shown is the base part number. For complete part number, refer to the current Viking price list schedule. 2. Based on NFPA 13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3. Requires a ½” ratchet (not available from Viking). 4. Also optional for removal of the protective cap. Ideal for sprinkler cabinets. 5. cULus Listed as corrosion resistant. 6. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers, the Belleville spring is exposed. 7. The sprinkler temperature rating is stamped on the deflector. 8. The installer tool is for push-on style cover plates only. FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9)TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 3 of 6 Form No. F_012116 20.06.26 Rev 20.2 TABLE 2: COVER PLATE ORDERING INFORMATION Instructions: (1) Select a Cover Plate Base Part Number (2) Add the suffix for the desired Finish (3) Add the suffix for the required Cover Plate Nominal Rating. Example: 23190MC/W = 165 °F (74 °C) Temperature Rated, 2-3/4” (70 mm) diameter, Thread-On style, Round Cover Plate with a Painted White finish. 1: Select a Cover Plate Base Part Number3 2: Select a FinishThread-On Style Push-On Style Base Part Number1 Size Inch (mm)Type Base Part Number Size Inch (mm)Type Description Suffix5 23190 2-3/4 (70)Round 23447 2-3/4 (70)Round Polished Chrome F 23174 3-5/16 (84)Round 23463 3-5/16 (84)Round Brushed Chrome F-/B 23179 3-5/16 (84)Square 23482 3-5/16 (84)Square Bright Brass B 231935 2-3/4 (70)Stainless Steel Round 234555 2-3/4 (70)Stainless Steel Round Antique Brass B-/A Brushed Brass B-/B 231835 3-5/16 (84)Stainless Steel Round 234735 3-5/16 (84)Stainless Steel Round Brushed Copper E-/B Painted White M-/W Painted Ivory M-/I Painted Black M-/B 3: Temperature Rating Matrix1,2 Cover Plate Nominal Rating (Required) Temperature Classification Sprinkler Nominal Rating Sprinkler Maximum Ambient Ceiling Temperature2 Suffix 135 °F (57 °C)Ordinary 155 °F (68 °C)100 °F (38 °C)A 165 °F (74 °C)Intermediate 200 °F (93 °C)150 °F (65 °C)C Footnotes 1. Part number shown is the base part number. For complete part number, refer to the current Viking price list schedule. 2. The sprinkler temperature rating is stamped on the deflector. 3. Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 4. Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above. 5. Stainless Steel versions are not available with any finishes or paint. FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9)TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 4 of 6 Form No. F_012116 20.06.26 Rev 20.2 Approval ChartViking VK494, 4.9 K-factor Residential Concealed Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the Design Criteria. For Ceiling types refer to current editions of NFPA 13, 13R or 13D S p r i n k l e r B a s e Part Number 1 SIN NPT Thread Size Nominal K-factor Maximum Water Working PressureInchesmmU.S.metric 2 20759 VK494 1/2 15 4.9 70.6 175 psi (12 bar) Max. Coverage Area 6 W X L Ft. X Ft. (m X m) Flow GPM (LPM) Pressure PSI (bar)Deflector to Ceiling Installation Type Listings and Approvals3,5 Minimum Spacing Ft. (m)155 °F (68 °C), 200 °F (93 °C) Temperature Rated Sprinklers 4 12 X 12 (3.7 X 3.7) 13 (49.2) 7.0 (0.48) Refer to Figure 2 Concealed with Cover Plate Assembly. See Footnote 7. See Footnotes 8, & 9 8 (2.4) 14 X 14 (4.3 X 4.3) 13 (49.2) 7.0 (0.48) 16 X 16 (4.9 X 4.9) 13 (49.2) 7.0 (0.48) 18 X 18 (5.5 X 5.5) 17 (64.4) 12.0 (0.83) 20 X 20 (6.1 X 6.1) 20 (75.7) 16.7 (1.15) Footnotes 1. Part number shown is the base part number. For complete part number, refer to the current Viking price schedule. 2. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. 4. Listed by Underwriter’s Laboratories, Inc. for use in the U.S., Canada, and European Union. 5. Meets New York City requirements, effective July 1, 2008. 6. For areas of coverage smaller than shown, use the “Flow” and “Pressure” for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum “Flow” and “Pressure” used. 7. Other paint colors are available on request with the same listings as the standard finish colors. Stainless Steel cover plates are not available with any finishes or paint. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. 8. Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 7. 9. C-UL-US-EU Listed as corrosion resistant - Electroless Nickel PTFE (ENT) FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9)TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 5 of 6 Form No. F_012116 20.06.26 Rev 20.2 DESIGN CRITERIA (Also refer to the Approval Chart.) UL Listing Requirements (C-UL-US-EU): When using Viking Residential Concealed Pendent Sprinkler VK494 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover-age and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, or • Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the “design area” in accordance with sections 9.5.2.1 or 10.2.4.1.2 of the current edition of NFPA 13. • Minimum distance between residential sprinklers: 8 ft. (2.4 m). NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT: Always refer to Bulletin Form No. F_080415 - Best Practices for Residential Sprinkler Handling and Installation. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be in-stalled in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Sprinkler and Adapter Assembly • Protective cap removed • Use wrench 14047W/B** Step 1: Carefully slide the wrench sideways around the deflector and pins Sprinkler Wrench Part No. 14047W/B** ** A 1/2” ratchet is required (Not available from Viking) 2-1/4” (57 mm) diameter opening required in the ceiling. Step 2: Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Figure 1: Sprinkler Installation and Proper Wrench Usage NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047W/B** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. Sprinkler wrench flat Sprinkler frame arms FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9)TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 6 of 6 Form No. F_012116 20.06.26 Rev 20.2 Figure 2: Sprinkler Dimensions and Cover Installation 1/2” (15 mm) NPT 2-1/4”(57 mm)2-9/16” (65 mm)Maximum 2-1/16” (52 mm)Minimum 2-3/4” (70 mm) or 3-5/16” (84 mm)NOTE: Upon sprinkler activation, the deflector descends to approximately 13/16” (21 mm) below the sprinkler body. Figure 3: Identification of Custom Paint for Concealed Covers All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 4: Square Cover Assembly 3-5/16” (84 mm)FACTORY APPLIE D C USTO M P AI NT COLORReplaces Form No. F_012116 Rev 20.1 (Added cover plate options.) FREEDOM® RESIDENTIAL UPRIGHT SPRINKLER VK467 (K4.9) TECHNICAL DATA Page 1 of 6 Form No. F_090413 18.10.18 Rev 17.1.P65 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1. DESCRIPTION Viking Freedom® Residential Upright Sprinkler VK467 is a small, thermosensitive, glass- bulb residential sprinkler available in several different finishes and temperature ratings to meet varying design requirements. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL-US-EU Listed as corro- sion resistant as indicated in the Approval Chart. The orifice design, with a K-Factor of 4.9 (70.6 metric†), allows efficient use of available water supplies for the hydraulically designed fire-protection system. The glass bulb operating element and special deflector characteris- tics meet the challenges of residential sprinkler standards. 2. LISTINGS AND APPROVALS UL Listed (C-UL-US-EU): Category VKKW NYC Approved: MEA 89-92-E, Volume 35 Refer to the Approval Chart Design Criteria for C-UL-US-EU Listing requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 2014. Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2” (15 mm) NPT Nominal K-Factor: 4.9 U.S. (70.6 metric†) †Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4” (58 mm) Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Brass UNS-C23000 or Bronze UNS-C22000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Polytetrafluoroethylene (PTFE) Tape Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Compression Screw: Brass UNS-C36000 For ENT coated sprinklers: Belleville spring - Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Sprinkler: Base Part No. 19154 Order Sprinkler VK467 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the tempera- ture rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 155 °F (68 °C) = B, 175 °F (79 °C) = D For example, sprinkler VK467 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 19154AB. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to Viking website.) Sprinkler Wrenches: A. Standard Wrench: Part No. 21475M/B (available since 2017) Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A (available since 1971) B. Twelve-head capacity: Part No. 01725A (available since 1971) Replaces Form No. F_090413 Rev 17.1 (Added P65 Warning.) FREEDOM® RESIDENTIAL UPRIGHT SPRINKLER VK467 (K4.9) TECHNICAL DATA Page 2 of 6 Form No. F_090413 18.10.18 Rev 17.1.P65 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Model VK467 Sprinkler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating1 Maximum Ambient Ceiling Temperature2 Bulb Color Ordinary 155 °F (68 °C)100 °F (38 °C)Red Intermediate 175 °F (79 °C)150 °F (65 °C)Yellow Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion Resistant Coatings3: ENT Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For ENT coated sprinklers, the waterway is coated. Note that the spring is exposed on sprinklers with ENT coating. Figure 1: Standard Sprinkler Wrench 21475M/B Protective Sprinkler Clip Wrench Flat FREEDOM® RESIDENTIAL UPRIGHT SPRINKLER VK467 (K4.9) TECHNICAL DATA Page 3 of 6 Form No. F_090413 18.10.18 Rev 17.1.P65 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval ChartViking VK467, 4.9 K-Factor Residential Upright Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to NFPA 13, 13R or 13D 2013 Editions Sprinkler Base Part Number1 SIN NPT Thread Size Nominal K-Factor Maximum Water Working Pressure Overall Length Inches mm U.S.metric2 Inches mm 19154 VK467 1/2 15 4.9 70.6 175 psi (12 bar)2-1/4 58 Max. Coverage Area4 Ft.X Ft. (m X m) Ordinary Temp Rating (155 °F/68 °C) Intermediate Temp Rating (175 °F/79 °C) Deflector to Ceiling Installation Type Listings and Approvals3 Minimum Spacing Ft. (m) Flow4 GPM (L/min) Pressure4 PSI (bar) Flow4 GPM (L/min) Pressure4 PSI (bar) 5 NYC NSF 12 X 12 (3.7 X 3.7) 14 (53.0) 8.16 (0.56) 14 (53.0) 8.16 (0.56) 3 - 5 inches Upright See Foot- note 7 and 9. See Foot- note 6. See Foot- note 7. 9 (2.74) 14 X 14 (4.3 X 4.3) 14 (53.0) 8.16 (0.56) 14 (53.0) 8.16 (0.56) 16 X 16 (4.9 X 4.9) 16 (60.6) 10.66 (0.73) 16 (60.6) 10.66 (0.73) 12 X 12 (3.7 X 3.7) 15 (56.8) 9.37 (0.65) 15 (56.8) 9.37 (0.65) 5 - 10 inches 14 X 14 (4.3 X 4.3) 15 (56.8) 9.37 (0.65) 15 (56.8) 9.37 (0.65) 16 X 16 (4.9 X 4.9) 18 (68.1) 13.49 (0.93) 18 (68.1) 13.49 (0.93) 12 X 12 (3.7 X 3.7) 15 (56.8) 9.37 (0.65)---- 1 to 3 inch- es below 14 inch beams 14 X 14 (4.3 X 4.3) 15 (56.8) 9.37 (0.65)---- 16 X 16 (4.9 X 4.9) 18 (68.1) 13.49 (0.93)---- Footnotes 1 Part number shown is the base part number. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. 4 For areas of coverage smaller than shown, use the “Flow” and “Pressure” for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum “Flow” and “Pressure” used. 5 Listed by Underwriter’s Laboratories, Inc. for use in the U.S., Canada, and European Union. 6 Meets New York City requirements, effective July 1, 2008. 7 Approved Finishes are: Brass, Chrome, White Polyester, and Black Polyester8 8 Other paint colors are available on request with the same C-UL-US-EU listings as the standard finish colors. 9 C-UL-US-EU listed as corrosion resistant - Electroless Nickel PTFE (ENT) FREEDOM® RESIDENTIAL UPRIGHT SPRINKLER VK467 (K4.9) TECHNICAL DATA Page 4 of 6 Form No. F_090413 18.10.18 Rev 17.1.P65 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESIGN CRITERIA (Also refer to the Approval Chart.) UL Listing Requirements (C-UL-US-EU): When using Viking Residential Upright Sprinkler VK467 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of coverage and mini- mum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The mini- mum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the Approval Chart for NFPA 13D and NFPA13R applications for each listed area of coverage, or • Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the “design area” in accordance with sections 8.5.2.1 or 8.6.2.1 of NFPA 13. • Minimum distance between residential sprinklers: 9 ft. (2.74 m). BEAM CEILING GUIDELINES C-UL-US-EU Listed for installation in residential occupancies with beam ceilings (with horizontal ceilings only). Refer to the Approval Chart for sprinkler areas of coverage and hydraulic design. Sprinkler Location: Locate sprinklers on the underside of the beams (not in the bays or pockets formed by the beams). Refer to Figure 2. The vertical distance from the sprinkler deflector to the bottom of the primary beam must be between 1” and 3” (25 to 76 mm). The horizontal distance from the centerline of the sprinkler to the primary beam cannot be more than 2” (51 mm) (Figure 2). Beam Position: Directly attached to the underside of a combustible or non-combustible smooth ceiling of any height. Beam Size and Shape (Cross section): • Depth: Maximum 14” (356 mm) for primary beams. Secondary beam depth cannot be greater than the primary beam. • Width: Unlimited. • Beam Shape: Rectangular to circular. Beam Types: Combustible or non-combustible, solid surface, solid or hollow core. Beam Spacing: A. For primary beams, the distance from the wall to the center of the nearest primary beam must be at least 3’-4” (1.0 m), and not more than one-half the listed sprinkler spacing. Note: Sprinklers may not be required to be located in the first beam nearest the wall. Center-to-center distance between primary beams is to be a maximum of 16 ft (4.9 m). Refer to Figure 3A. B. When beam pockets created by the primary beams exceed 20 ft (6.1 m) in length, secondary beams are required as follows (also refer to Figure 3B): 1. Secondary beam depth must be equal to primary beam depth. 2. Secondary beams must be placed so that the bays formed by the primary beams do not exceed 20 ft (6.1 m) in length. C. When primary beam spans do not exceed 20 ft (6.1 m), secondary beams (not required) may have any distance from wall to nearest secondary beam and any distance center to center between secondary beams. Refer to Figure 3C. Also: When primary beam spans exceed 20ft (6.1m) an alternate protection scheme for the compartment would be to calculate all the sprinklers in the com- partment. Refer to Figure 5. • More stringent design requirement. • Secondary beams or baffles would not be required for a compartment space design. • The minimum required discharge from each sprinkler would utilize flow rates given in the Approval Chart for NFPA 13D and NFPA13R applications Lintels: Must be present over doorways exiting the compartment. Lintel height must be at least 8” (203 mm), or at least the depth of the primary beams, whichever is greater. Beam and Soffit Arrangements: If a soffit is installed, beams may be arranged within the soffit. The cross section of the soffit may be any size, pro- vided it does not create an obstruction to water distribution per the obstruction rules of NFPA 13 for residential sprinklers. Where there is a soffit, beam spacing from the wall is to be measured from the face of the soffit rather than the wall. Refer to Figure 3D. NOTE: The sprinkler area of coverage is to be measured from the wall. Definitions: • Primary beams: The main beams that run primarily in one direction. • Secondary beams: The beams that run perpendicular to the main beams. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No.s F_080190, F_080814, and F_080415 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. FREEDOM® RESIDENTIAL UPRIGHT SPRINKLER VK467 (K4.9) TECHNICAL DATA Page 5 of 6 Form No. F_090413 18.10.18 Rev 17.1.P65 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Figure 2: Sprinkler Positioning Under Primary Beams Figure 3: Sprinkler Positioning Under Primary Beams FREEDOM® RESIDENTIAL UPRIGHT SPRINKLER VK467 (K4.9) TECHNICAL DATA Page 6 of 6 Form No. F_090413 18.10.18 Rev 17.1.P65 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Figure 5: Alternate Entire Compartment Protection Scheme Example Figure 4B: Primary Beam Spans over 20 ft (6.1 m)Figure 4A: Primary Beam Spans up to 20 ft (6.1 m) All dimensions are measured to wall faces and to centerlines of beams. A = Distance from wall to nearest primary beam: Minimum: 3 ft 4 in (1.0 m). Maximum: No more than 1/2 listed sprinkler spacing. B = Spacing between primary beams: 16 ft (4.9 m) maximum C = Beam depth: 14” (356 mm) maximum D = Beam span: 20 ft (6.1 m) maximum All dimensions are measured to wall faces and to centerlines of beams. A = Distance from wall to nearest primary beam: Minimum: 3 ft 4 in (1.0 m). Maximum: No more than 1/2 listed sprinkler spacing. B = Spacing between primary beams: 16 ft (4.9 m) maximum C = Beam depth: 14” (356 mm) maximum D = 20 ft (6.1 m) maximum for secondary beams that are to be equal in depth for primary beams and that are required so that primary beam pockets do not exceed 20 ft (6.1 m). All dimensions are measured to wall faces and to centerlines of beams. • Primary beam spans exceeding 20 ft (6.1 m) • Secondary beams or baffles not required • Calculate all sprinklers in compartment (Above example 6 sprinklers) EXAMPLE Replaces Form No. F_090413 Rev 17.1 (Added P65 Warning.) QUICK RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERSTECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Form No. F_031993 19.06.24 Rev 19.1 Page 1 of 8 1. DESCRIPTION Viking Quick Response Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry systems and preaction systems where it is necessary to prevent water or condensation from entering the drop nipple before sprinkler operation. They may also be installed in spaces subject to freezing and supplied from a wet system in an adjacent heated area. Viking Quick Response Dry HSW Sprinklers are available in various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indi- cated in the Approval Charts. (Note: FM Global has no approval classification for Polyester coatings as corrosion resistant.) NOTE: When installed in some corrosive environments, the Polyester finish may change color. This natural discoloration over time is not in itself an indi- cation of corrosion and should not be treated as such. All sprinklers installed in corrosive environments should be replaced or tested as described in NFPA 25 on a more frequent basis. 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2013 and 2015 NYC Approved: MEA 89-92-E, Volume 15 Refer to Approval Chart 1 and Design Criteria on page 106c for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 106d for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 1993. Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: 175 psi (12 bar). Factory tested pneumatically to 100 psi (6.89 bar) Thread size: 1” NPT or 25 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric*) for all listed and approved lengths. * Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 °F (-55 °C) Covered by the following U.S. Patent numbers: 8,636,075 and 8,376,060 and 10,220,231 Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Phosphor Bronze UNS-C51000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Compression Screw: Brass UNS-C36000 Pip Cap: Brass UNS-C31400 or UNS-C31600 Pip Cap Adapter: Brass UNS-C36000 Orifice: Copper UNS-C22000 or UNS-C11000 Tube: ERW Hydraulic Steel Tube Support (Internal): Stainless Steel UNS-S30400 Barrel: Steel Pipe UNS-G10260, Electrodeposited Epoxy Base finish Barrel End and Threads: QM Brass Sleeve (for Adjustable Standard style only): Brass UNS-C26000 or UNS-C26800 Escutcheon Materials: Adjustable Standard Dry Escutcheons: Brass UNS-C26000 or UNS-C26800 Recessed Dry Escutcheons: Cold Rolled Steel UNS-G10080 ENT Coated Adjustable and Recessed Escutcheons: Stainless Steel UNS-S30400 Ordering Information: (Also refer to the current Viking price list.) Order QR Dry HSW Sprinklers by first adding the appropriate suffix for the sprinkler finish, the appropriate suffix for the temperature rating, and then the suffix for the length (“A” dimension) to sprinkler base part number. Order in a specific length noted as the “A” dimension. The “A” dimension is the distance from the face of the fitting (tee) to the desired finished surface of the wall in which it is to be installed. Viking Technical Data may be found on The Viking Corporation’s Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. For Light Hazard Occupancies Only Replaces Form No. F_031993 Rev 15.1.P65 (Added patent number.) QUICK RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERSTECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Form No. F_031993 19.06.24 Rev 19.1 Page 2 of 8 These sprinklers are listed and approved in lengths from 1-1/2” to 45-1/2” (38.1 mm to 1,156 mm) for the adjustable standard style, 3” to 47” (76.2 mm to 1,194 mm) for the plain barrel style, and 3-1/4” to 47-1/2” (82.5 mm to 1,207 mm) for the adjustable recessed style. Lengths exceeding the standard lengths are available, with no approvals, on a “made-to-order” basis: Recessed Dry HSW up to 65- 1/2” (1,664 mm). Adjustable Standard Dry HSW up to 63-1/2” (1,613 mm). Plain Barrel Dry HSW up to 65” (1,651 mm). Contact the manufacturer for more information. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, and ENT = JN Temperature Suffix: 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 286 °F (141 °C) = G Escutcheon Suffix = Y for the adj. recessed sprinkler with the Model G-1 Escutcheon (no suffix needed for the Model E-1 Escutcheon). For example, sprinkler VK182 with 1” NPT Threads, a Chrome finish, a 155 °F (68 °C) temperature rating, the Model G-1 Escutcheon, and “A” length of 10” = Part No. 08386UFBY10. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the “Sprinkler Accessories” section.) Sprinkler Wrenches: A. Standard Wrench: Part No. 07297W/B (available since 1991) B. Wrench for recessed sprinklers: Part No. 07565W/B** (available since 1991) **A ½” ratchet is required (not available from Viking). Dry Sprinkler Protective Cover: Part No. 15610 Replacement Escutcheons: A. Adjustable Standard Dry Escutcheon: Base Part No. 08086F B. Model E-1 Recessed Dry Escutcheon Cup: Base Part No. 05459A 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the internal parts to open the water- way. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire.6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Quick Response Dry Horizontal Sidewall Sprinkler is available through a network of domestic and international distribu- tors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating1 Maximum Ambient Ceiling Temperature2 Bulb Color Ordinary 155 °F (68 °C)100 °F (38 °C)Red Intermediate 175 °F (79 °C)150 °F (65 °C)Yellow Intermediate 200 °F (93 °C)150 °F (65 °C)Green High 286 °F (141 °C)225 °F (107 °C)Blue Sprinkler Finishes: Brass, Chrome, White Polyester, and ENT Corrosion-Resistant Coating3,4: White Polyester and ENT in all temperature ratings Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant Polyester and ENT coatings have passed the standard corrosion test required by the approving agencies indi-cated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Note: These coatings are NOT corrosion proof. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. Polyester and ENT coatings are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. 4 When installed in some corrosive environments, the Polyester finish may change color. This natural discoloration over time is not in itself an indication of corrosion and should not be treated as such. All sprinklers installed in corrosive environments should be replaced or tested as described in NFPA 25 on a more frequent basis. Figure 1: Standard Sprinkler Wrench 07297W/B QUICK RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERSTECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Form No. F_031993 19.06.24 Rev 19.1 Page 3 of 8 Figure 3: Adjustable Standard Dry Horizontal Sidewall Sprinkler Figure 4: Adjustable Standard Escutcheon Installation Figure 2: Wrench 07565W/B for Adjustable Recessed Dry Horizontal Sidewall Sprinklers QUICK RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERSTECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Form No. F_031993 19.06.24 Rev 19.1 Page 4 of 8 Approval Chart 1 (UL) Quick Response Dry Horizontal Sidewall Sprinklers For Light Hazard Occupancies Only Maximum 175 PSI (12 bar) WWP Sprinkler Base Part No.1 SIN Style Thread Size Nominal K-Factor2 Order Length Increment Listings and Approvals4 (Refer also to Design Criteria on page 106e.) NPT BSP U.S.metric3 Inches mm cULus5 NYC6 VdS LPCB 08384U VK178 Adjustable Standard 1”--5.6 80.6 1/2”12.7 A1, A5 A1 -------- 16458U --25 mm --80.6 1/2”12.7 A1, A5 ---------- 08386U VK182 Adjustable Recessed 1”--5.6 80.6 1/4”6.35 B2, B6 B2 -------- 16454U --25 mm --80.6 1/4”6.35 B2, B6 ---------- 08388U VK174 Plain Barrel 1”--5.6 80.6 1/2”12.7 A3 A4 -------- 16456U --25 mm --80.6 1/2”12.7 A3 ---------- Approved Temperature Ratings A - 155 °F (68 °C), 175 °F (79°C), 200 °F (93 °C), and 286 °F (141 °C) B - 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) Approved Finishes and “A” Dimensions 1* - Chrome, or White Polyester7 sprinkler with a Chrome, Brass, or White Polyester Sleeve and Escutcheon with “A” dimensions 1-1/2” to 45-1/2” (38.1 mm to 1,156 mm) 2* - Chrome, or White Polyester7 with “A” dimensions 3-1/4” to 47-1/2” (82.5 mm to 1,207 mm) 3 - Chrome, Brass, White Polyester7, or ENT7 with “A” dimensions 3” to 47” (76.2 mm to 1,194 mm) 4 - Chrome or Brass with “A” dimensions 3” to 47” (76.2 mm to 1,194 mm) 5 - ENT7 sprinkler with an ENT7 Sleeve and Escutcheon with “A” dimensions 1-1/2” to 45-1/2” (38.1 mm to 1,156 mm) 6 - ENT7 with “A” dimensions 3-1/4” to 47-1/2” (82.5 mm to 1,207 mm) *Brass Finish is listed and approved but not standard offering, lead times of 6-8 weeks required. (Matching Brass escutcheons are not available.) Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 K-Factor applies for standard lengths (“A” Dimensions indicated above). 3 Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 4 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 5 Listed by Underwriter’s Laboratories for use in the U.S. and Canada for Light Hazard occupancies only. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 15. 7 cULus Listed as corrosion resistant. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) NOTE: When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-Bl tees. When selecting other CPVC fittings, contact Viking Technical Services. cULus Listing Requirements: Quick Response Dry Horizontal Sidewall Sprinklers are cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edi- tion of NFPA 13 for standard spray sprinklers. • Limited to Light Hazard occupancies only. • Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. • Minimum spacing allowed is 6 ft. (1.8 m). • Deflector must be positioned between 4” and 6” (102 mm and 152 mm) below the ceiling. Keep the top of the deflector oriented parallel with the ceiling. • Locate no less than 4” (102 mm) from end walls. • Maximum distance from end walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. • The sprinkler installation and obstruction rules contained in NFPA 13 for sidewall standard spray sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page DRY1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. QUICK RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERSTECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Form No. F_031993 19.06.24 Rev 19.1 Page 5 of 8 Approval Chart 2 (FM) Quick Response Dry Horizontal Sidewall Sprinklers For Light Hazard Occupancies Only Maximum 175 PSI (12 bar) WWP Sprinkler Base Part No.1 SIN Style Thread Size Nominal K-Factor2 Order Length Increment FM Approvals4 (Refer also to Design Criteria below.)NPT BSP U.S.metric3 Inches mm 08384U VK178 Adjustable Standard 1”--5.6 80.6 1/2”12.7 A1 16458U --25 mm --80.6 1/2”12.7 A1 08386U VK182 Adjustable Recessed 1”--5.6 80.6 1/4”6.35 B2 16454U --25 mm --80.6 1/4”6.35 B2 08388U VK174 Plain Barrel 1”--5.6 80.6 1/2”12.7 A3 16456U --25 mm --80.6 1/2”12.7 A3 Approved Temperature Ratings A - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141 °C) B - 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) Approved Finishes and “A” Dimensions 1* - Bright Brass, Chrome, White Polyester, or ENT5 with “A” dimensions 1-1/2” to 45-1/2” (38.1 mm to 1,156 mm) 2* - Bright Brass, Chrome, White Polyester, or ENT5 with “A” dimensions 3-1/4” to 47-1/2” (82.5 mm to 1,207 mm) 3 - Brass, Bright Brass, Chrome, White Polyester, or ENT5 “A” dimensions 3” to 47” (76.2 mm to 1,194 mm) *Brass Finish is listed and approved but not standard offering, lead times of 6-8 weeks required. (Matching Brass escutcheons are not available.) Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 K-Factor applies for standard lengths (“A” Dimensions indicated above). 3 Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 4 This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 5 FM approved as corrosion resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) NOTE: When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-Bl tees. When selecting other CPVC fittings, contact Viking Technical Services. FM Approval Requirements: The Dry HSW Sprinklers in the Approval Chart above are FM Approved as quick response Non-storage standard spray sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including 2-0) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflec- tor distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page DRY1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other simi- lar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. QUICK RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERSTECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Form No. F_031993 19.06.24 Rev 19.1 Page 6 of 8 Figure 6: Adjustable Recessed Dry Horizontal Sidewall Sprinkler with the Model G-1 Escutcheon Figure 5: Adjustable Recessed Dry Horizontal Sidewall Sprinkler with the Model E-1 Escutcheon QUICK RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERSTECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Form No. F_031993 19.06.24 Rev 19.1 Page 7 of 8 Press the cover together until it snaps closed. Figure 8: Dry Horizontal Sidewall Sprinkler Cover Part Number 15610 (shown with an Adjustable Standard Dry HSW Sprinkler) (Optional for temporary use with Viking Dry HSW Sprinklers until finish work is completed around the sprinkler.) After the sprinkler is installed, carefully place the cover over the dry sprinkler as shown.NOTE: Remove the sprinkler clip and cover before placing the system in service! Top View - Dry HSW Sprinkler Side View - Sprinkler Cover 15610 NOTE: Shown with an Adjustable Standard Dry HSW Sprinkler. The protective cover may also be used with the Adjustable Recessed or Plain Barrel style Dry HSW Sprinkler. Figure 7: Quick Response Plain Barrel Dry Horizontal Sidewall Sprinkler QUICK RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERSTECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Form No. F_031993 19.06.24 Rev 19.1 Page 8 of 8 Figure 10: Dry Sprinkler Seal (Adjustable Standard Dry HSW Sprinkler is Shown) Figure 9: Dry Horizontal Sidwall Sprinkler Required Minimum Barrel Length Based on Ambient Temperature in the Protected Area (Adjustable Standard Dry HSW Sprinkler is Shown) Replaces Form No. F_031993 Rev 15.1.P65 (Added patent number.) Sprinkler Model Max. Working Pressure psi (bar) Maximum Coverage Area Width x Length ft x ft (m x m) Flow Rate gpm (L/min) Pressure psi (bar) Sprinkler Identification Number (SIN) DH56 Dry EC 250 (17.2) 28 x 8 (8.5 x 2.4)23 (87.1)16.9 (1.2) RA1664 28 x 10 (8.5 x 3)28 (106)25 (1.7) Table A DH56 Dry EC HSW with standard escutcheon Features • Coverage for long and narrow light hazard spaces such as hallways, decks, and rooms • Coverage area up to 28 ft (8.5m) long and 10 ft (3m) deep • Available in four trim styles and a variety of finish combina- tions. Product Description The Reliable Model DH56 Dry Extended Coverage Horizontal Sidewall Sprinkler is a quick-response sprinkler utilizing a sensitive 3mm glass bulb thermal element listed for use in light hazard applications. Dry sprinklers are intended for use on wet, dry, and preaction systems to protect indoor and outdoor areas that are subject to freezing. When used on wet systems, it is important that a minimum exposed length of barrel inside the face of the wall or insulation is provided to offset conduction of potentially freezing temperatures from the unconditioned (sprinkler) end along the barrel. See Figure 6 for guidelines on using dry sprinklers on wet systems. Environments where dry sprinklers are employed are often corrosive. For this reason, Model DH56 dry sprinklers have a special wax fillet placed in the gap between the cup that supports the bulb and the wrenching boss. This wax prevents contaminants from entering the internal portion of the drop nipple and must not be removed. www.reliablesprinkler.com Application The Model DH56 is a horizontal sidewall dry sprinkler intended for installation in light hazard occupancies in accordance with NFPA 13. These sprinklers are designed to provide fire protection in long and narrow spaces such as hallways, corridors, decks and rooms up to 28 feet (8.5m) wide and 10 feet (3m) deep. Model DH56 sprinklers are rated for 250 psi (17.2 bar) and can be mounted between 4 and 12 inches (102 and 305mm) down from the ceiling. cULus Listed Model DH56 Dry Extended Coverage Horizontal Sidewall Sprinkler Bulletin 016 March 2022 Model DH56 EC HSW Coverage Area Figure 1 Model DH56 EC Horizontal Sidewall Sprinkler SIN RA1664 Technical Specifications Style: Extended Coverage Horizontal Sidewall Threads: 1” NPT or ISO7-1R1 Nominal K-Factor: 5.6 (80) Max. Working Pressure: 250 psi (17.2 bar) Max. Spacing: 28 ft (8.5m) Min. Spacing: 16 ft (4.9m) Material Specifications Inlet Fitting: Brass Alloy Flip Disk: Brass Alloy Seal: PTFE Coated Belleville Spring Outer Tube: Galvanized Steel Pipe Sprinkler Frame: Brass Alloy Bulb Insert: Copper Alloy Thermal Element: Glass Bulb Deflector: Bronze Alloy Load Screw: Brass Alloy Sprinkler Finishes See finish combination tables on following pages Sensitivity Quick Response Temperature Ratings 155°F (68°C) 175°F (79°C) 200°F (93°C) Recessed Escutcheons/Cover Plates Standard Escutcheon HB Escutcheon FP Escutcheon SWC Cover Plate Listings and Approvals cULus Listed for Light Hazard 28' [8.5m] Maximum Spacing 16' [4.9m] Minimum Spacing MODEL DH56 DRY SPRINKLER 4" [100mm] Min. from Ceiling 12" [300mm] Max. from Ceiling Wall Floor Coverage Area DH56DRYCOVAREA 28' [8.5m] 8' [2.4m] or 10' [3m] Based on Selected Discharge Flow and Pressure Shown here with standard escutcheon. See pages 3-6 for additional trim styles Bulletin 016 March 2022 Page 2 of 10 www.reliablesprinkler.com Model DH56 Dry Sprinkler with Standard Escutcheon Figure 2 System Tee 3" Dia. [76mm] Nominal Position of EscutcheonWallInlet Fitting 1" [25mm] Escutcheon Adjustment 1-15/16"" [53mm] Ceiling "A" Dimension 1/2" [12mm] Escutcheon Adjustment Sprinkler Can 2-1/8" Dia. [54mm] Hole in Wall016STD-A 4" [100mm] Min. 12" [300mm] Max. DH56 DRY HSW SPRINKLER, STANDARD ESCUTCHEON 1/2" [12mm] Nominal Protrusion 5/8" [16mm] 1/2" [12mm] "A" Dimension = 2" to 48" (50mm to 1200mm) Finish Combinations: Standard Escutcheon Sprinkler Escutcheon(2)(3) Bronze Polished Stainless Steel Bronze Laquered Brass Chrome Polished Stainless Steel White Polyester(1)White Polyester Black Polyester(1)Black Polyester Custom Color Polyester(1)Custom Color Polyester Electroless Nickel PTFE(1)Polished Stainless Steel Notes: 1. UL Listed as Corrosion Resistant. 2. Escutcheons do not carry corrosion resistant listings. 3. Base material is 316 stainless steel. “A” Dimension: 2” to 48” (50mm to 1200mm) in 1/4” (6mm) increments Bulletin 016 March 2022 Page 3 of 10 www.reliablesprinkler.com “A” Dimension: 3-1/2” to 36” (90mm to 900mm) in 1/4” (6mm) increments Bulletin 016 March 2022 Page 4 of 10 www.reliablesprinkler.com Model DH56 Dry Sprinkler with HB Escutcheon Figure 3 System Tee 3-1/2" [89 mm] Dia. Nominal Escutcheon Position 1/2" [13 mm] Escutcheon Adjustment "A" Dimension 2 1/2" Dia. [64 mm] Hole in Wall 1/2" [13 mm] Escutcheon Adjustment 1-15/16"" [49mm] 5/8" [16 mm] Sprinkler Can Inlet Fitting Escutcheon 1-1/4" [32mm] Nominal Projection 1-1/4" [32mm]WallCeiling 016HB Finish Combinations: HB Escutcheon Sprinkler Escutcheon(2)(3) Bronze Chrome Chrome Chrome White Polyester(1)White Polyester Black Polyester(1)Black Polyester Custom Color Polyester(1)Custom Color Polyester Electroless Nickel PTFE(1)Stainless Steel Notes: 1. UL Listed as Corrosion Resistant. 2. Escutcheons do not carry corrosion resistant listings. 3. Base material is cold rolled steel unless noted. “A” Dimension: 3-1/2” to 48” (90mm to1200mm) in 1/4” (6mm) increments Bulletin 016 March 2022 Page 5 of 10 www.reliablesprinkler.com Model DH56 Dry Sprinkler with FP Escutcheon Figure 4 Hole in Wall 3-1/4" [82mm] 2 5/8" Dia. [67mm] "A" Dimension System Tee Wall4" [102mm] Min. 12" [305mm] Max. Ceiling Sprinkler Cup Escutcheon Inlet Fitting 1/4" [6mm] 1/4" [6mm] Escutcheon Adjustment Escutcheon Adjustment 1 1/4" [32mm] Nom Nominal Position of Escutcheon 5/8" [16mm] 016FP Finish Combinations: FP Recessed Escutcheon Sprinkler(1)Escutcheon(3)(4) Bronze Brass Chrome Chrome White Polyester(2)White Polyester Black Polyester(2)Black Polyester Custom Color Polyester(2)Custom Color Polyester Electroless Nickel PTFE(2)Stainless Steel Notes: 1. Cup for FP Recessed is unfinished galvanized steel except electroless nickel PTFE sprinkler uses a stainless steel cup. 2. UL Listed as Corrosion Resistant. 3. Escutcheons do not carry corrosion resistant listings. 4. Base material is cold rolled steel unless noted. Note: Do not install the Model DH56 Dry Sprinkler with FP recessed escutcheon in locations where there is positive pressure in the cavity behind the sprinkler relative to the pressure at the sprinkler. “A” Dimension: 3-1/2” to 48” (90mm to1200mm) in 1/4” (6mm) increments Bulletin 016 March 2022 Page 6 of 10 www.reliablesprinkler.com Model DH56 Dry Sprinkler with SWC Cover Plate Figure 5 4" [102mm] Min 12" [305mm] Max "A" Dimension 1/4" [6mm] Cover Plate Adjustment 1/4" [6mm] Cover Plate Adjustment Nominal Position of Cover Plate System Tee Inlet Fitting 5/8" [16mm] 1-9/16" [40mm] 2-5/8" [67mm] Dia. Hole in Wall 3-7/32" Dia. [82mm] Sprinkler Cup 016SWC WallCeiling Finish Combinations: SWC Concealed Cover Plate Sprinkler(1)Cover Plate(2) Bronze White Polyester Chrome Bright Chrome Dull Bright Brass Unfinished Bronze Custom Color Notes: 1. Cup for SWC Concealed is unfinished galvanized steel. 2. Cover plates do not carry corrosion resistant listings. Note: Do not install the Model DH56 Dry Sprinkler with SWC cover plate in locations where there is positive pressure in the cavity be- hind the sprinkler relative to the pressure at the sprinkler. Bulletin 016 March 2022 Page 7 of 10 www.reliablesprinkler.com Figure 6 Bulletin 016 March 2022 Page 8 of 10 www.reliablesprinkler.com Figure 7 Installation (General) Dry sprinklers connected to wet pipe systems must be installed as indicated in Figure 6 and as required by NFPA 13 with the Exposed Minimum Barrel Length located in a heated area. Reliable Model DH56 dry sidewall sprinklers may be installed in ductile or malleable cast iron threaded tees, or CPVC tees and adapters upon verification that the sprinkler inlet fitting does not interfere with the interior of the fitting (see Figure 7). DO NOT install Reliable Model DH56 dry sidewall sprinklers into elbows or couplings, welded outlets, mechanical tees, or gasket sealed CPVC fittings. DH56 HSW with Standard Escutcheon Cut a 2-1/8” (54mm) diameter hole in the wall as shown in Fig. 2. Apply a PTFE based sealant to the sprinkler threads before installing into the fitting. Use the Model F3R installation wrench (see Fig. 8) on the square boss to tighten the sprinkler until it is secured in the sprinkler fitting. Installation is completed by removing the orange glass bulb protector and sliding the escutcheon over the finished sleeve until tight to the finished surface. DH56 HSW with HB Escutcheon Cut a 2-1/2” (64mm) diameter hole in the wall as shown in Fig. 3. Apply a PTFE based sealant to the sprinkler threads before installing into the fitting. Use the Model F3R installation wrench (see Fig. 8) on the square boss to tighten the sprinkler until it is secured in the sprinkler fitting. Installation is completed by removing the orange glass bulb protector and sliding the skirt over the finished sleeve until tight to the finished suface. DH56 HSW with FP Recessed Escutcheon Cut a 2-5/8” (67mm) diameter hole in the wall as shown in Fig. 4. Apply a PTFE based sealant to the sprinkler threads before installing into the fitting. Use the Model F3R installation wrench (see Fig. 8) on the square boss to tighten the sprinkler until it is secured in the sprinkler fitting. Installation is completed by removing the orange glass bulb protector and pushing (or threading) the FP escutcheon into the threaded cup. Final adjustment is made by turning the FP escutcheon clockwise until the flange makes full contact with the wall surface. DH56 HSW SWC Concealed Cover Plate Cut a 2-5/8” (67mm) diameter hole in the wall as shown in Fig. 5. Apply a PTFE based sealant to the sprinkler threads before installing into the fitting. Use the Model F3R installation wrench (see Fig. 8) on the square boss to tighten the sprinkler until it is secured in the sprinkler fitting. Installation is completed by removing the orange glass bulb protector and pushing (or threading) the SWC cover plate into the threaded cup. Final adjustment is made by turning the cover plate clockwise until the cover plate flange makes full contact with the finished surface. Note: 1. The Model XLO2 installation wrench for FP Recessed and SWC Concealed installations has a open side to accommodate the sprinkler deflector and can only be inserted in one way (see Figure 8). Care must be taken not to damage the deflector during installation. 2. Do not over-tighten sprinklers into fittings. It is recommended that Reliable dry sprinklers be installed using the wrench referenced in this bulletin. A pipe wrench may also be used to install dry sprinklers provided that it only engages the outer tube (steel pipe) of the assembly. Note that a pipe wrench will impart a large amount of torque into the final assembly. This torque will need to be matched or exceeded to remove the sprinkler at a later date. A leak free joint can normally be obtained by installing the sprinkler to a minimum torque of 22 ft-lb (30 N-m) after applying an appropriate thread sealant. 3. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling, and installation. Reliable installation wrenches are designed to install sprinklers while bulb protectors are in place. REMOVE THE PROTECTORS AT THE TIME THE SPRINKLER SYSTEM IS PLACED INTO SERVICE. Removal of the protectors before this time may leave the glass bulb vulnerable to damage. Remove protectors by undoing the clasp by hand. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. 4. Do not remove the wax fillet in the gap between the cup that supports the bulb and the wrenching boss. Step 3 Step 2 Step 1 Figure 8XLO2 Installation Procedure Bulletin 016 March 2022 Page 9 of 10 www.reliablesprinkler.com Maintenance Reliable Model DH56 series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non-operation during a fire event. Guarantee For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents US Patent No. 7,841,418 Wrench Options F3R Wrench (Standard & HB trims)XLO2 Wrench (FP recessed and SWC trims) Ordering Information Specify: Sprinkler Type • Model DH56 Dry Extended Coverage Horizontal Sidewall Sprinkler Trim Style • Standard Escutcheon • HB Escutcheon • FP Recessed Esctucheon • SWC Cover Plate Temperature Rating • 155°F (68°C) • 175°F (79°C) • 200°F (93°C) Finish • See available combinations (depending on trim style) on pages 3-6 Length • “A” Dimension (face of fitting to finished wall surface, in 1/4” [6mm] increments) Installation Wrench • Model F3R (Standard & HB trims) • Model XLO2 (FP Recessed & SWC trims) Bulletin 016 March 2022 Page 10 of 10 www.reliablesprinkler.com P/N 9999970308 SECTION E Alarms and Supervisory Devices Size inches (mm) Voltage Model Number Stock Number Current (Max.) Typical dB at 10 ft. (3m) (2) Minimum dB at 10 ft. (3m) (1) 6 (150)12VDC MBA-6-12 1750070 .12A 85 76 8 (200)12VDC MBA-8-12 1750080 .12A 90 77 10 (250)12VDC MBA-10-12 1750060 .12A 92 78 6 (150)24VDC MBA-6-24 1750100 .06A 87 77 8 (200)24VDC MBA-8-24 1750110 .06A 91 79 10 (250)24VDC MBA-10-24 1750090 .06A 94 80 6 (150)24VAC PBA246 1806024*.17A 91 78 8 (200)24VAC PBA248 1808024*.17A 94 77 10 (250)24VAC PBA2410 1810024*.17A 94 78 6 (150)120VAC PBA1206 1806120*.05A 92 83 8 (200)120VAC PBA1208 1808120*.05A 99 84 10 (250)120VAC PBA12010 1810120*.05A 99 86 All DC bells are polarized and have built-in transient protection. * Does not have ULC listing. BELLS PBA-AC & MBA-DC These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4" (101mm) square electrical box for indoor use or on a model BBK-1 weatherproof backbox or BBX-1 deep weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. PRINTED IN USA PAGE 1 OF 2MFG. #5400776 - REV Y-1 01/13 UL, ULC, and FM Approved Sizes Available: 6" (150mm), 8" (200mm) and 10" (250mm) Voltages Available: 24VAC 120VAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling Burglar Alarm Environment: Indoor or outdoor use (See Note 1) -40° to 150°F (-40° to 66°C) (Outdoor use requires weatherproof backbox.) Termination: AC Bells - 4 No. 18 AWG stranded wires DC Bells - Terminal strip Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox Model BBX-1 deep weatherproof backbox Potter Electric Signal Company, LLC • St. Louis, MO, • Phone: 866-572-3005/Canada 888-882-1833 • www.pottersignal.com In outdoor or wet installations, bell must be mounted with weatherproof backbox, BBK-1 or BBX-1. Standard electrical boxes will not provide a weatherproof enclosure. If the bell and/or assembly is exposed to moisture, it may fail or create an electrical hazard. Notes: 1. Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30° to 150°F (-34° to 66°C). 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. 3. ULC only applies to MBA DC bells. * BELLS PBA-AC & MBA-DC PRINTED IN USA PAGE 2 OF 2MFG. #5400776 - REV Y-1 01/13 A.C. BELLS WHITE (IN) BLACK (IN) WHITE (OUT) BLACK (OUT) FROM CONTROL PA NEL OR PRECEDING BELL CAUTION: WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. NOTES: 1. WHEN USING AC BELLS, TERMINATE EACH EXTRA WIRE SEPA RATELY AFTER LAST BELL. 2. END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS. DWG# 776-3 5 3/4” (146) 1 5/8” (41) DWG# 776-2 3 3/8” (86) 4 1/4” (108) 3 3/8” (86) 5” (127) Weatherproof Backbox Dimensions Inches (mm) Fig. 2 Box has one threaded 1/2" conduit entrance Wiring (rear view) Fig. 3 +_FA CP To Next Device or End-of-Line Resistor Installation 1. The bell shall be installed in accordance with NFPA 13, 72, or local AHJ. The top of the device shall be no less than 90" AFF and not less than 6" below the ceiling. 2. Remove the gong. 3. Connect wiring (see Fig. 3). 4. Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). 5. Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). 6. Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). 2 11/16” (68)DWG# 776-1 10” (250)8” (200)6” (150) Bells Dimensions Inches (mm) Fig. 1 2” (51)4 1/4” (108)3 3/8” (85.9)BBX-1 Failure to install striker down will prevent bell from operating.